Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 15 de 15
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Clin Implant Dent Relat Res ; 26(4): 704-713, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38711297

RÉSUMÉ

OBJECTIVE: To assess the clinical outcomes by means of implant and prosthetic survival of late placed and early loaded implants with a hydrophilic, moderately rough surface for partially edentulous patients after a follow-up of 8.5 to 9.5 years. MATERIALS AND METHODS: A prospective case series study involving 15 patients with single, late placed and early loaded implants in the posterior mandible was performed. Clinical and radiographical parameters, including biological and technical complications and patient satisfaction, were assessed. RESULTS: From an initial sample of 15 patients, 12 were included. A total of 16 implants were observed. After a mean follow-up of 9 years and 7 months (SD ± 3.8 months), implant success and survival rate were 100%. The prosthetic survival rate was 100%, and the prosthetic success rate was 93.8% since a major chipping was observed. No biological complications were observed, and the mean modified plaque index was 0.03 (SD ± 0.09) with a mean probing pocket depth of 2.95 mm (SD ± 0.09). A mean marginal bone level (MBL) of 0.04 mm (SD ± 0.88) and a mean VAS of 9.42 (SD ± 0.90) for patient satisfaction were recorded. CONCLUSION: Late placed and early loaded implants with a moderately rough endosseal surface are a reliable option for rehabilitating partially edentulous patients. An implant survival rate of 100% and a prosthodontic success rate of 93.8% were observed. Patient satisfaction scores were high and peri-implant hard and soft tissues remained healthy. The study findings should be carefully interpreted because of the small sample.


Sujet(s)
Mandibule , Humains , Études prospectives , Mâle , Femelle , Mandibule/chirurgie , Mandibule/imagerie diagnostique , Adulte d'âge moyen , Études de suivi , Adulte , Satisfaction des patients , Implants dentaires , Propriétés de surface , Mâchoire partiellement édentée/rééducation et réadaptation , Mâchoire partiellement édentée/chirurgie , Mâchoire partiellement édentée/imagerie diagnostique , Sujet âgé , Conception de prothèse dentaire , Pose d'implant dentaire endo-osseux/méthodes , Pose immédiate d'implant dentaire/méthodes , Interactions hydrophobes et hydrophiles , Résultat thérapeutique
2.
Article de Anglais | MEDLINE | ID: mdl-37966052

RÉSUMÉ

OBJECTIVES: The purpose of this prospective study was to determine the inter- and intraindividual variability in virtual single-tooth implant positioning based on the level of expertise, specialty, total time spent, and the use of a prosthetic tooth setup. MATERIALS AND METHODS: Virtual implant planning was performed on matched pre- and post-extraction intraoral scans (IOS), and cone-beam computed tomography scans of 15 patients. Twelve individual examiners, involving six novices and experts from oral surgery and prosthodontics positioned the implants, first based on anatomical landmarks utilizing only the post-extraction, and second with the use of the pre-extraction IOS as a setup. The time for implant positioning was recorded. After 1 month, all virtual plannings were performed again. The individual implant positions were superimposed to obtain 3D deviations using a software algorithm. RESULTS: An interindividual variability with mean angular, crestal, and apical positional deviations of 3.8 ± 1.94°, 1.11 ± 0.55, and 1.54 ± 0.66 mm, respectively, was found. When assessing intraindividual variability, deviations of 3.28 ± 1.99°, 0.78 ± 0.46, and 1.12 ± 0.61 mm, respectively, were observed. Implants planned by experts exhibited statistically lower deviations compared to those planned by novices. Longer planning times resulted in lower deviations in the experts' group but not in the novices. Oral surgeons demonstrated lower crestal, but not angular and apical deviations than prosthodontists. The use of a setup only led to minor adjustments. CONCLUSIONS: Substantial inter- and intraindividual variability exists during implant positioning utilizing specialized software planning. The level of expertise and the time invested influenced the deviations of the implant position during the planning sequence.

3.
J Prosthodont ; 2023 Nov 13.
Article de Anglais | MEDLINE | ID: mdl-37955870

RÉSUMÉ

PURPOSE: This in vitro study aimed to assess the positional accuracy during the sequence of static computer-assisted implant surgery (sCAIS) according to the anatomical characteristics of the alveolar ridge. MATERIAL AND METHODS: Maxillary bone models with six single tooth gaps including clinical scenarios of healed alveolar ridge (HR), single-rooted (SRS), and three-rooted socket (TRS) morphologies were used in this study. Positional deviations during implant placement procedures were evaluated after the pilot osteotomy (PD), final osteotomy (FD), and implant placement with respect to the pre-planned implant position by using a software package. ANOVA and post hoc analyses were performed. RESULTS: A total of 90 implants were included in this study. Higher mean angular, crestal, and apical deviations were found after the PD and FD (3.5 ± 2.4°, 0.7 ± 0.3 mm, and 1.4 ± 0.8 mm versus 3.6 ±2.2°, 0.6 ± 0.3 mm, and 1.2 ± 0.6 mm) compared to IP (2.8 ± 1.6°, 0.7 ± 0.3 mm, and 1.2 ± 0.5 mm, p ≤ 0.004). Implants placed in TRS demonstrated higher mean angular, crestal, and apical deviations (4.0 ± 1.7°, 0.8 ± 0.3 mm, and 1.6 ± 0.5 mm) compared to implants placed in SRS (2.5 ± 1.2°, 0.7 ± 0.3 mm, and 1.1 ± 0.4 mm) or HR (2.0 ± 0.9°, 0.5 ± 0.3 mm, and 0.8 ± 0.4 mm, p < 0.001). CONCLUSIONS: Positional deviations during sCAIS procedures are initiated with the first implant osteotomy and persist throughout the drilling sequence. However, deviations slightly decreased after implant placement. The alveolar ridge morphology is strongly associated with positional deviations. Higher deviations were observed in three-rooted and single-rooted sockets simulating an immediate approach compared to healed sites simulating a delayed protocol.

4.
Article de Anglais | MEDLINE | ID: mdl-37493201

RÉSUMÉ

OBJECTIVES: The primary aim of this in vitro study was to assess the effect of alveolar residual bone height in the posterior maxilla on the accuracy of the final implant position via free-handed and static Computer-Assisted Implant Placement (sCAIP). The secondary aim was to evaluate the influence of the maxillary sinus morphology on the accuracy of final implant position. MATERIALS AND METHODS: Partially edentulous standardized maxillary models simulating three different residual bone heights and different sinus floor morphologies were investigated. One-hundred eighty equally distributed implants, which were placed either free-handed or sCAIP, constituted the study sample. 3D digital deviations were obtained by superimposing the post-surgical scans on the initial treatment plan. RESULTS: Angular and linear deviation assessment demonstrated higher implant position accuracy in the sCAIP group. sCAIP revealed similar outcomes independently of the alveolar bone height and sinus floor morphology. Contrarily, in the free-handed group, alveolar bone height and sinus morphology statistically affected the final implant position. Non-parametric three-way ANOVA showed significance for implant placement protocol (p < .0001) and alveolar bone height (p ≤ .02) when angular, and linear deviations were evaluated. Sinus morphology was statistically significantly associated with angular deviation (p = .0009). CONCLUSIONS: sCAIP demonstrated higher 3D implant position accuracy. Alveolar bone height (strongly) and sinus morphology are associated with the accuracy of final implant position when the free-handed implant protocol is followed. However, these anatomical factors did not affect final implant position during sCAIP.

5.
J Periodontol ; 94(11): 1315-1323, 2023 Nov.
Article de Anglais | MEDLINE | ID: mdl-37332251

RÉSUMÉ

BACKGROUND: This study aimed to evaluate the reliability and reproducibility of different non-invasive methods for the assessment of peri-implant mucosal thickness. METHODS: Subjects with two adjacent dental implants in the central maxillary region were included in this study. Three different methods to assess facial mucosal thickness (FMT) were compared: digital file superimposition using Digital Imaging and Communication in Medicine (DICOM) and stereolithography (STL) files of the arch of interest (DICOM-STL), DICOM files alone, and non-ionizing ultrasound (US). Inter-rater reliability agreements between different assessment methods were analyzed using inter-class correlation coefficients (ICCs). RESULTS: A total of 50 subjects with 100 bone-level implants constituted the study population. Assessment of FMT using STL and DICOM files demonstrated excellent inter-rater reliability agreement. Mean ICC values of 0.97 and 0.95 were observed in the DICOM-STL and DICOM groups, respectively. Comparison between the DICOM-STL and US revealed good agreement, with an ICC of 0.82 (95% CI: 0.74 to 0.88) and a mean difference of -0.13 ± 0.50 mm (-1.13 to 0.86). Comparison between DICOM files alone versus US showed good agreement, with an ICC of 0.81 (95% CI: 0.73 to 0.89) and a mean difference of -0.23 ± 0.46 mm (-1.12 to 0.67). Comparison between DICOM-STL and DICOM files revealed excellent agreement, with an ICC of 0.94 (95% CI: 0.91 to 0.96) and a mean difference of 0.1 ± 0.29 mm (LOA -0.47 to 0.46). CONCLUSIONS: Quantification of peri-implant mucosal thickness via analysis of DICOM-STL files, DICOM files, or US assessment are comparably reliable and reproducible methods.


Sujet(s)
Implants dentaires , Maxillaire , Humains , Études transversales , Reproductibilité des résultats , Maxillaire/imagerie diagnostique , Tomodensitométrie à faisceau conique
6.
Int J Mol Sci ; 24(9)2023 May 04.
Article de Anglais | MEDLINE | ID: mdl-37175951

RÉSUMÉ

Healing after tooth extraction involves a series of reparative processes affecting both alveolar bone and soft tissues. The aim of the present study was to investigate whether activation of molecular signals during the healing process confers a regenerative advantage to the extraction socket soft tissue (ESsT) at 8 weeks of healing. Compared to subepithelial connective tissue graft (CTG), qRT-PCR analyses revealed a dramatic enrichment of the ESsT in osteogenic differentiation markers. However, ESsT and CTG shared characteristics of nonspecialized soft connective tissue by expressing comparable levels of genes encoding abundant extracellular matrix (ECM) proteins. Genes encoding the transforming growth factor-ß1 (TGF-ß1) and its receptors were strongly enriched in the CTG, whereas the transcript for the insulin-like growth factor-1 (IGF-1) showed significantly high and comparable expression in both tissues. Mechanical stimulation, by the means of cyclic strain or matrix stiffness applied to primary ESsT cells (ESsT-C) and CTG fibroblasts (CTG-F) extracted from the tissue samples, revealed that stress-induced TGF-ß1 not exceeding 2.3 ng/mL, as measured by ELISA, in combination with IGF-1 up to 2.5 ng/mL was able to induce the osteogenic potential of ESsT-Cs. However, stiff matrices (50 kPa), upregulating the TGF-ß1 expression up to 6.6 ng/mL, caused downregulation of osteogenic gene expression in the ESsT-Cs. In CTG-Fs, endogenous or stress-induced TGF-ß1 ≥ 4.6 ng/mL was likely responsible for the complete lack of osteogenesis. Treatment of ESsT-Cs with TGF-ß1 and IGF-1 proved that, at specific concentrations, the two growth factors exhibited either an inductive-synergistic or a suppressive activity, thus determining the osteogenic and mineralization potential of ESsT-Cs. Taken together, our data strongly warrant the clinical exploration of ESsT as a graft in augmentative procedures during dental implant placement surgeries.


Sujet(s)
Alvéole dentaire , Facteur de croissance transformant bêta-1 , Humains , Facteur de croissance IGF-I/génétique , Facteur de croissance IGF-I/pharmacologie , Ostéogenèse , Régénération osseuse , Protéines de la matrice extracellulaire
7.
BMC Oral Health ; 23(1): 297, 2023 05 16.
Article de Anglais | MEDLINE | ID: mdl-37194038

RÉSUMÉ

BACKGROUND: Odontogenic fibroma (OF) is a rare benign odontogenic tumor of ectomesenchymal origin, mostly affecting the tooth-bearing portions of the jaws in middle-aged patients. Whilst small lesions tend to be clinically asymptomatic, varying unspecific clinical symptoms occur with an increase in size and may mimic odontogenic or other maxillofacial bone tumors, cysts, or fibro-osseous lesions of the jaws. CASE PRESENTATION: A 31-year-old female patient presented with a hard, non-fluctuating protrusion in the vestibule of the upper right maxilla. It was visualized on cone beam computed tomography (CBCT) as space-occupying osteolysis with the displacement of the floor and facial wall of the maxillary sinus, mimicking a cyst-like lesion. The tissue was surgically removed and identified as an OF in the histopathological examination. One year after the surgery, restitution of regular sinus anatomy and physiological intraoral findings were observed. CONCLUSIONS: This case report emphasizes that rare entities, like the maxillary OF presented, often demonstrate nonspecific clinical and radiological findings. Nevertheless, clinicians need to consider rare entities as possible differential diagnoses and plan the treatment accordingly. Histopathological examination is essential to conclude the diagnosis. OF rarely recur after proper enucleation.


Sujet(s)
Kystes , Fibrome , Tumeurs odontogènes , Ostéolyse , Adulte d'âge moyen , Femelle , Humains , Adulte , Maxillaire/chirurgie , Ostéolyse/imagerie diagnostique , Ostéolyse/anatomopathologie , Récidive tumorale locale/anatomopathologie , Tumeurs odontogènes/imagerie diagnostique , Tumeurs odontogènes/chirurgie , Kystes/anatomopathologie , Fibrome/anatomopathologie , Fibrome/chirurgie
8.
Clin Oral Implants Res ; 34(4): 320-329, 2023 Apr.
Article de Anglais | MEDLINE | ID: mdl-36727584

RÉSUMÉ

OBJECTIVES: To evaluate the effect of drilling sequence, guide-hole design, and alveolar ridge morphology on the accuracy of implant placement via static computer-assisted implant surgery (sCAIS). MATERIALS AND METHODS: Standardized maxillary bone models including single-tooth gaps with fresh extraction sockets or healed alveolar ridge morphologies were evaluated in this study. Implants were placed using different drilling sequences (i.e., complete [CDS] or minimum [MDS]), and guide-hole designs (i.e., manufacturer's sleeve [MS] or sleeveless [SL] guide-hole designs). The time for implant placement via sCAIS procedures was also recorded. The angular, crestal, and apical three-dimensional deviations between planned and final implant positions were digitally obtained. Statistical analyses were conducted by a non-parametric three-way ANOVA (α = .05). RESULTS: Based on a sample size analysis, a total of 72 implants were included in this study. Significantly higher implant position accuracy was found at healed sites compared to extraction sockets and in SL compared to MS guide-hole design in angular, crestal, and apical 3D deviations (p ≤ .048). A tendency for higher accuracy was observed for the CDS compared to the MDS, although the effect was not statistically significant (p = .09). The MDS required significantly shorter preparation times compared with CDS (p < .0001). CONCLUSION: Implant placement via sCAIS resulted in higher accuracy in healed sites than extraction sockets, when using SL compared to MS guides, and tended to be more accurate when using CDS compared to MDS. Therefore, even though surgery time was shorter with MDS, its use should be limited to strictly selected cases.


Sujet(s)
Implants dentaires , Chirurgie assistée par ordinateur , Pose d'implant dentaire endo-osseux/méthodes , Processus alvéolaire/chirurgie , Ordinateurs
9.
Int J Implant Dent ; 9(1): 4, 2023 02 07.
Article de Anglais | MEDLINE | ID: mdl-36749441

RÉSUMÉ

PURPOSE: This in vitro study aimed at comparing the accuracy of freehand implant placement with static computer-assisted implant surgery (sCAIS), utilizing a keyless and a drill-key implant system and two guide-hole designs. METHODS: A total of 108 implants were placed in 18 partially edentulous maxillary models simulating two different alveolar ridge morphologies. 3D digital deviations between pre-planned and post-operative implant positions were obtained. Guide material reduction was assessed in the keyless implant system for the manufacturer's sleeve and sleeveless guide-hole designs. RESULTS: sCAIS using a sleeveless guide-hole design demonstrated smaller mean angular, crestal and apical deviations compared to sCAIS utilizing a manufacturer's sleeve and the freehand group (2.6 ± 1.6°, vs 3.3 ± 1.9°, vs 4.0 ± 1.9°; 0.5 ± 0.3 mm, vs 0.6 ± 0.3 mm, vs 0.8 ± 0.3 mm; and 1.0 ± 0.5 mm, vs 1.2 ± 0.7 mm, vs 1.5 ± 0.6 mm). Smaller angular and apical mean deviations were observed in the keyless implant system as compared with the drill-key implant system (3.1 ± 1.7°, vs 3.5 ± 1.9°, p = 0.03; and 1.2 ± 0.6 mm, vs 1.4 ± 0.7 mm, p = 0.045). Overall, smaller angular, crestal, and apical deviations (p < 0.0001) were observed in healed alveolar ridges (2.4 ± 1.7°, 0.5 ± 0.3 mm, and 0.9 ± 0.5 mm) than in extraction sockets (4.2 ± 1.6°, 0.8 ± 0.3 mm, and 1.6 ± 0.5 mm). Higher mean volumetric material reduction was observed in sleeveless than in manufacturer's sleeve guide-holes (- 0.10 ± 0.15 mm3, vs - 0.03 ± 0.03 mm3, p = 0.006). CONCLUSIONS: Higher final implant positional accuracy was observed in sCAIS for the keyless implant system, with a sleeveless guide-hole design, and in healed ridges. Sleeveless guide holes resulted in higher volumetric material reduction compared with the manufacturer's sleeve.


Sujet(s)
Implants dentaires , Bouche édentée , Chirurgie assistée par ordinateur , Humains , Pose d'implant dentaire endo-osseux/méthodes , Chirurgie assistée par ordinateur/méthodes , Ordinateurs
10.
J Dent ; 130: 104426, 2023 03.
Article de Anglais | MEDLINE | ID: mdl-36652971

RÉSUMÉ

OBJECTIVES: The primary aim of this in vitro study was to evaluate the influence of alveolar ridge morphologies on the accuracy of static Computer-Assisted Implant Surgery (sCAIS). The secondary aims were to evaluate the influence of guide-hole design and implant macro-design on the accuracy of the final implant position. METHODS: Eighteen standardized partially edentulous maxillary models with two different types of alveolar ridge morphologies were used. Each model was scanned via cone beam computer tomography prior to implant placement and scanned with a laboratory scanner prior to and following implant placement using sCAIS. The postsurgical scans were superimposed on the initial treatment planning position to measure the deviations between planned and postsurgical implant positions. RESULTS: Seventy-two implants were equally distributed to the study groups. Implants placed in healed alveolar ridges showed significantly lower mean deviations at the crest (0.36 ± 0.17 mm), apex (0.69 ± 0.36 mm), and angular deviation (1.86 ± 0.99°), compared to implants placed in fresh extraction sites (0.80 ± 0.29 mm, 1.61 ± 0.59 mm, and 4.33 ± 1.87°; all p<0.0001). Implants placed with a sleeveless guide-hole design demonstrated significantly lower apical (1.02 ± 0.66 mm) and angular (2.72 ± 1.93°) deviations compared to those placed with manufacturer's sleeves (1.27 ± 0.67 mm; p = 0.01, and 3.46 ± 1.9°; p = 0.02). Deep-threaded tapered bone level implants exhibited significantly lower deviations at the crest (0.49 ± 0.28 mm), apex (0.97 ± 0.63 mm), and angular deviations (2.63 ± 1.85°) compared to shallow-threaded parallel-walled bone level implants (0.67 ± 0.34 mm; p = 0.0005, 1.32 ± 0.67 mm; p = 0.003, and 3.56 ± 1.93°; p = 0.01). CONCLUSIONS: The accuracy of the final implant position with sCAIS is determined by the morphology of the alveolar ridge, the design of the guide holes, and the macrodesign of the implant. CLINICAL SIGNIFICANCE: Higher accuracy in the final implant position was observed with implants placed in healed alveolar ridge morphologies, in implants with deep-threaded tapered macro-design, and when sleeveless surgical guide holes were used.


Sujet(s)
Implants dentaires , Pose d'implant dentaire endo-osseux/méthodes , Conception assistée par ordinateur , Processus alvéolaire , Tomodensitométrie à faisceau conique , Ordinateurs , Imagerie tridimensionnelle
11.
Swiss Dent J ; 132(9): 599-606, 2022 Sep 05.
Article de Allemand | MEDLINE | ID: mdl-36052964

RÉSUMÉ

The preservation of osseointegration is fundamental for the long-term success of dental implants. Breakdown of osseointegration may occur in cases of aseptic implant loosening, a poorly understood process leading to sudden implant failure. So far, no evidence-based therapy concept exists for implants with aseptic loosening. The present case report demonstrates the re-osseointegration of a dental implant in the mandible of a 79-year-old female patient with mamma carcinoma after loss of osseointegration caused by aseptic loosening. The only treatment performed was a correction of the occlusion. After a period of eight months, a re-osseointegration was observed clinically and radiographically, and remained stable for the follow-up period of 21 months. Reduction of occlusal forces after correction of the occlusion may have facilitated a re-osseointegration. Potential influences of concurrent antineoplastic chemotherapy regarding breast carcinoma or further unknown influences on implant re-osseointegration cannot be ruled out.


Sujet(s)
Implants dentaires , Ostéo-intégration , Sujet âgé , Force occlusale , Femelle , Humains , Mandibule
12.
Clin Oral Implants Res ; 32(8): 1008-1018, 2021 Aug.
Article de Anglais | MEDLINE | ID: mdl-34129707

RÉSUMÉ

OBJECTIVES: To evaluate the long-term effectiveness of 6 mm implants in various indications with a micro-rough surface after 4.6-18.2 years in function and to assess key factors associated with implant survival, success, and biologic/technical complications. MATERIALS AND METHODS: Fifty-five patients with seventy-four 6 mm implants placed from 2000 to 2013 attended the re-examination assessing well-established clinical and radiographic parameters, biologic and prosthetic complications, and patient-reported outcome measures. RESULTS: Five implants were lost after a mean follow-up period of 9.1 years resulting in a survival rate of 93.2%. All losses occurred in free-end situations in the mandible. Smoking habit significantly reduced implant survival (hazard ratio 36.25). Two implants exhibited a history of peri-implantitis, and one implant showed progressive marginal bone loss (MBL) resulting in a success rate of 89.2%. The mean MBL amounted to 0.029 mm. Increased MBL was found for implants placed in the maxilla (0.057 mm) and for implants with a diameter of 4.1 mm (0.043 mm). Soft tissue thickness (1.39 mm) and width of keratinized mucosa (1.91 mm) had no effect on MBL. Patient-reported outcome measures showed high satisfaction (mean VAS scores 88%) and high quality of life (mean OHIP-G14 score 2.2). CONCLUSION: The present study demonstrated survival and success rates of 93.2% and 89.2% for 6 mm implants used in various indications. A factor leading to higher implant failure was smoking, whereas modulating factors increasing annual MBL included implants placed in the maxilla and implants with a diameter of 4.1 mm compared to 4.8 mm.


Sujet(s)
Résorption alvéolaire , Implants dentaires , Résorption alvéolaire/imagerie diagnostique , Conception de prothèse dentaire , Prothèse dentaire implanto-portée , Échec de restauration dentaire , Études de suivi , Humains , Qualité de vie , Études rétrospectives , Résultat thérapeutique
13.
Swiss Dent J ; 131(5): 437-441, 2021 05 10.
Article de Allemand | MEDLINE | ID: mdl-33952560

RÉSUMÉ

Modern treatment protocols in implant dentistry focus on lower morbidity and patient-centered outcomes, in addition to commonly applied treatment success criteria. Prosthetically-driven digital planning followed by static computer-assisted implant surgery (sCAIS) may minimize the need for bone augmentation by ideally utilizing the residual crest and thereby improve patient satisfaction. A healthy 37-year-old female suffered from agenesis of both second mandibular premolars and presented wide single-tooth gaps on both sides of the mandible with a moderate (left) and pronounced (right) horizontal bone deficiency. 3D implant planning allowed ideal implant positioning in the residual bone volume while respecting critical anatomical structures. This enabled a flapless sCAIS procedure without bone grafting in the left mandible. On the right side, the insufficient bone volume was augmented simultaneously to the sCAIS using GBR. The clinical and radiographic parameters showed a good oral health status in the 1-year postop examination. The final implant position presented a minimal angular and horizontal deviation from the initial planning. The patient was highly satisfied with the two applied methods but preferred the flapless procedure.


Sujet(s)
Implants dentaires , Chirurgie assistée par ordinateur , Adulte , Ordinateurs , Pose d'implant dentaire endo-osseux , Femelle , Humains , Bouche , Flux de travaux
14.
Clin Oral Investig ; 25(6): 3513-3525, 2021 Jun.
Article de Anglais | MEDLINE | ID: mdl-33263141

RÉSUMÉ

OBJECTIVES: To assess survival rates and frequency of complications for immature and mature autotransplanted teeth after at least 1 year in function. MATERIALS AND METHODS: All consecutive patients who had undergone tooth autotransplantation between 2000 and 2018 were invited to a clinical and radiographic follow-up examination. First, survival rates were calculated on the basis of a phone inquiry. A clinical follow-up examination allowed for the calculation of the success rate, i.e., absence of any potentially adverse clinical and radiographic findings of the autotransplanted teeth. Moreover, the effect of demographic, dental, and surgical variables on survival/success was analyzed statistically. RESULTS: Thirty-eight teeth in 35 patients were transplanted during the study period. Three teeth in 3 patients were excluded due to missing records. All other patients were successfully contacted and interviewed by phone. Out of these 35 transplants, 32 were still in function, and 3 had been extracted, yielding a 91.4% survival probability after a median follow-up of 3.4 years. Of the 32 teeth qualifying for the success analysis, 20 (62.5%) showed absence of potentially adverse findings, while 3 (9.4%) required root canal treatment (RCT). Out of the 9 mature, root-end resected transplants, 4 exhibited ongoing pulp canal obliteration, all with a single root canal. Postoperative and potentially adverse findings or failures were found more frequently in the group of mature transplants (55.6%) than immature transplants (30.4%) and for molars (72.7%) than premolars (17.6%) or canines (25%). None of the potential predictors had a statistically significant effect on survival or success. CONCLUSION: Autotransplanted teeth yielded a satisfying midterm survival rate regardless of their stage of development. An additional, extraoral root-end resection of mature transplants may lead to rates of revascularization and postoperative pulp canal obliteration higher than the data reported on unmodified mature transplants. CLINICAL RELEVANCE: Extraoral root-end resection of mature teeth shows promising outcomes for transplants especially with a single root canal and uncomplicated root morphology.


Sujet(s)
Apicectomie , Prémolaire , Études de suivi , Humains , Études rétrospectives , Transplantation autologue , Résultat thérapeutique
15.
J Neurosurg ; 128(4): 1250-1257, 2018 04.
Article de Anglais | MEDLINE | ID: mdl-28524798

RÉSUMÉ

OBJECTIVE Frontal ventriculostomy is one of the most frequent and standardized procedures in neurosurgery. However, many first and subsequent punctures miss the target, and suboptimal placement or misplacement of the catheter is common. The authors therefore reexamined the landmarks and rules to determine the entry point and trajectory with the best hit rate (HtR). METHODS The authors randomly selected CT scans from their institution's DICOM pool that had been obtained in 50 patients with normal ventricular and skull anatomy and without ventricular puncture. Using a 5 × 5-cm frontal grid with 25 entry points referenced to the bregma, the authors examined trajectories 1) perpendicular to the skull, 2) toward classic facial landmarks in the coronal and sagittal planes, and 3) toward an idealized target in the middle of the ipsilateral anterior horn (ILAH). Three-dimensional virtual reality ventriculostomies were simulated for these entry points; trajectories and the HtRs were recorded, resulting in an investigation of 8000 different virtual procedures. RESULTS The best HtR for the ILAH was 86% for an ideal trajectory, 84% for a landmark trajectory, and 83% for a 90° trajectory, but only at specific entry points. The highest HtRs were found for entry points 3 or 4 cm lateral to the midline, but only in combination with a trajectory toward the contralateral canthus; and 1 or 2 cm lateral to the midline, but only paired with a trajectory toward the nasion. The same "pairing" exists for entry points and trajectories in the sagittal plane. For perpendicular (90°) trajectories, the best entry points were at 3-5 cm lateral to the midline and 3 cm anterior to the bregma, or 4 cm lateral to the midline and 2 cm anterior to the bregma. CONCLUSIONS Only a few entry points offer a chance of a greater than 80% rate of hitting the ILAH, and then only in combination with a specific trajectory. This "pairing" between entry point and trajectory was found both for landmark targeting and for perpendicular trajectories, with very limited variability. Surprisingly, the ipsilateral medial canthus, a commonly reported landmark, had low HtRs, and should not be recommended as a trajectory target.


Sujet(s)
Ventriculostomie/méthodes , Ventricules cérébraux/imagerie diagnostique , Ventricules cérébraux/chirurgie , Femelle , Tête/imagerie diagnostique , Tête/chirurgie , Humains , Mâle , Adulte d'âge moyen , Tomodensitométrie , Réalité de synthèse
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE