Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 88
Filtrer
1.
Med Phys ; 51(6): 4402-4412, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38634859

RÉSUMÉ

BACKGROUND: Total marrow (lymphoid) irradiation (TMI/TMLI) is a radiotherapy treatment used to selectively target the bone marrow and lymph nodes in conditioning regimens for allogeneic hematopoietic stem cell transplantation. A complex field geometry is needed to cover the large planning target volume (PTV) of TMI/TMLI with volumetric modulated arc therapy (VMAT). Five isocenters and ten overlapping fields are needed for the upper body, while, for patients with large anatomical conformation, two specific isocenters are placed on the arms. The creation of a field geometry is clinically challenging and is performed by a medical physicist (MP) specialized in TMI/TMLI. PURPOSE: To develop convolutional neural networks (CNNs) for automatically generating the field geometry of TMI/TMLI. METHODS: The dataset comprised 117 patients treated with TMI/TMLI between 2011 and 2023 at our Institute. The CNN input image consisted of three channels, obtained by projecting along the sagittal plane: (1) average CT pixel intensity within the PTV; (2) PTV mask; (3) brain, lungs, liver, bowel, and bladder masks. This "averaged" frontal view combined the information analyzed by the MP when setting the field geometry in the treatment planning system (TPS). Two CNNs were trained to predict the isocenters coordinates and jaws apertures for patients with (CNN-1) and without (CNN-2) isocenters on the arms. Local optimization methods were used to refine the models output based on the anatomy of the patient. Model evaluation was performed on a test set of 15 patients in two ways: (1) by computing the root mean squared error (RMSE) between the CNN output and ground truth; (2) with a qualitative assessment of manual and generated field geometries-scale: 1 = not adequate, 4 = adequate-carried out in blind mode by three MPs with different expertise in TMI/TMLI. The Wilcoxon signed-rank test was used to evaluate the independence of the given scores between manual and generated configurations (p < 0.05 significant). RESULTS: The average and standard deviation values of RMSE for CNN-1 and CNN-2 before/after local optimization were 15 ± 2/13 ± 3 mm and 16 ± 2/18 ± 4 mm, respectively. The CNNs were integrated into a planning automation software for TMI/TMLI such that the MPs could analyze in detail the proposed field geometries directly in the TPS. The selection of the CNN model to create the field geometry was based on the PTV width to approximate the decision process of an experienced MP and provide a single option of field configuration. We found no significant differences between the manual and generated field geometries for any MP, with median values of 4 versus 4 (p = 0.92), 3 versus 3 (p = 0.78), 4 versus 3 (p = 0.48), respectively. Starting from October 2023, the generated field geometry has been introduced in our clinical practice for prospective patients. CONCLUSIONS: The generated field geometries were clinically acceptable and adequate, even for an MP with high level of expertise in TMI/TMLI. Incorporating the knowledge of the MPs into the development cycle was crucial for optimizing the models, especially in this scenario with limited data.


Sujet(s)
Moelle osseuse , Apprentissage profond , Planification de radiothérapie assistée par ordinateur , Radiothérapie conformationnelle avec modulation d'intensité , Radiothérapie conformationnelle avec modulation d'intensité/méthodes , Humains , Planification de radiothérapie assistée par ordinateur/méthodes , Moelle osseuse/effets des radiations , Dosimétrie en radiothérapie
2.
Radiol Med ; 129(3): 515-523, 2024 Mar.
Article de Anglais | MEDLINE | ID: mdl-38308062

RÉSUMÉ

PURPOSE: To improve the workflow of total marrow and lymphoid irradiation (TMLI) by enhancing the delineation of organs at risk (OARs) and clinical target volume (CTV) using deep learning (DL) and atlas-based (AB) segmentation models. MATERIALS AND METHODS: Ninety-five TMLI plans optimized in our institute were analyzed. Two commercial DL software were tested for segmenting 18 OARs. An AB model for lymph node CTV (CTV_LN) delineation was built using 20 TMLI patients. The AB model was evaluated on 20 independent patients, and a semiautomatic approach was tested by correcting the automatic contours. The generated OARs and CTV_LN contours were compared to manual contours in terms of topological agreement, dose statistics, and time workload. A clinical decision tree was developed to define a specific contouring strategy for each OAR. RESULTS: The two DL models achieved a median [interquartile range] dice similarity coefficient (DSC) of 0.84 [0.71;0.93] and 0.85 [0.70;0.93] across the OARs. The absolute median Dmean difference between manual and the two DL models was 2.0 [0.7;6.6]% and 2.4 [0.9;7.1]%. The AB model achieved a median DSC of 0.70 [0.66;0.74] for CTV_LN delineation, increasing to 0.94 [0.94;0.95] after manual revision, with minimal Dmean differences. Since September 2022, our institution has implemented DL and AB models for all TMLI patients, reducing from 5 to 2 h the time required to complete the entire segmentation process. CONCLUSION: DL models can streamline the TMLI contouring process of OARs. Manual revision is still necessary for lymph node delineation using AB models.


Sujet(s)
Apprentissage profond , Humains , Planification de radiothérapie assistée par ordinateur , Moelle osseuse/imagerie diagnostique , Irradiation ganglionnaire , Flux de travaux , Organes à risque/effets des radiations
3.
Prostate ; 84(4): 368-375, 2024 Mar.
Article de Anglais | MEDLINE | ID: mdl-38112222

RÉSUMÉ

BACKGROUND: In 2016 we published a phase II study exploring safety and efficacy of Stereotactic Body Radiation Therapy (SBRT) delivered with Volumetric Modulated Arc Therapy (VMAT) and Flattening Filter Free (FFF) beams techniques in prostate cancer (PC) patients. We present herein the updated results on late toxicity and long-term survival. METHODS: Patients enrolled in the study had a biopsy-confirmed localized PC and the features of a low- or intermediate-risk disease (National Comprehensive Network Criteria). The radiotherapy (RT) schedule consisted of 35 Gy delivered in five fractions every other day. Toxicities were registered according to the common toxicity adverse events v4.0. Biochemical recurrence was defined as an increase of prostate specific antigen after nadir, confirmed at least once. Local recurrence (LR) and distant metastases were detected either with Choline- or PSMA-PET/CT scans. Kaplan-Meier curves for Biochemical Recurrence-Free Survival (BFS), Local Control (LC), Distant Metastasis Free Survival (DMFS) and Cancer Specific Survival, were calculated by using MedCalc. RESULTS: Ninety patients were submitted to SBRT between February 2012 and March 2015. Fifty-eight patients (64.5%) had a Gleason Score of 6, while 32 (35.5%) had a Gleason Score of 7. A late grade 1 Genito-Urinary toxicity was observed in 54.5% of patients while a grade 2 in 3.3%. A late Gastro-intestinal grade 1 toxicity was reported in 18.9% of patients, while a grade 2 in 2.2%. Erectile dysfunction was reported by 13% of patients No heavier toxicities were observed. At a median follow-up of 102 months, 5- and 8-year BFS were 93.0% and 84.4% respectively, 5- and 8-year LC were 95.2% and 87.0% respectively, 5- and 8-year DMFS were 95.3% and 88.4%, respectively. CONCLUSIONS: This long-term update confirms that SBRT is a valid therapeutic strategy for low-intermediate risk PC. RT with VMAT and FFF warrants optimal results in terms of toxicity and disease control.


Sujet(s)
Tumeurs de la prostate , Radiochirurgie , Humains , Mâle , Grading des tumeurs , Tomographie par émission de positons couplée à la tomodensitométrie , Antigène spécifique de la prostate , Tumeurs de la prostate/anatomopathologie , Radiochirurgie/méthodes
4.
Curr Oncol ; 30(7): 7031-7042, 2023 07 22.
Article de Anglais | MEDLINE | ID: mdl-37504370

RÉSUMÉ

BACKGROUND: Hypo-fractionation can be an effective strategy to lower costs and save time, increasing patient access to advanced radiation therapy. To demonstrate this potential in practice within the context of temporal evolution, a twenty-year analysis of a representative radiation therapy facility from 2003 to 2022 was conducted. This analysis utilized comprehensive data to quantitatively evaluate the connections between advanced clinical protocols and technological improvements. The findings provide valuable insights to the management team, helping them ensure the delivery of high-quality treatments in a sustainable manner. METHODS: Several parameters related to treatment technique, patient positioning, dose prescription, fractionation, equipment technology content, machine workload and throughput, therapy times and patients access counts were extracted from departmental database and analyzed on a yearly basis by means of linear regression. RESULTS: Patients increased by 121 ± 6 new per year (NPY). Since 2010, the incidence of hypo-fractionation protocols grew thanks to increasing Linac technology. In seven years, both the average number of fractions and daily machine workload decreased by -0.84 ± 0.12 fractions/year and -1.61 ± 0.35 patients/year, respectively. The implementation of advanced dose delivery techniques, image guidance and high dose rate beams for high fraction doses, currently systematically used, has increased the complexity and reduced daily treatment throughput since 2010 from 40 to 32 patients per 8 h work shift (WS8). Thanks to hypo-fractionation, such an efficiency drop did not affect NPY, estimating 693 ± 28 NPY/WS8, regardless of the evaluation time. Each newly installed machine was shown to add 540 NPY, while absorbing 0.78 ± 0.04 WS8. The COVID-19 pandemic brought an overall reduction of 3.7% of patients and a reduction of 0.8 fractions/patient, to mitigate patient crowding in the department. CONCLUSIONS: The evolution of therapy protocols towards hypo-fractionation was supported by the use of proper technology. The characteristics of this process were quantified considering time progression and organizational aspects. This strategy optimized resources while enabling broader access to advanced radiation therapy. To truly value the benefit of hypo-fractionation, a reimbursement policy should focus on the patient rather than individual treatment fractionation.


Sujet(s)
COVID-19 , Radio-oncologie , Humains , Pandémies , Radio-oncologie/méthodes , Fractionnement de la dose d'irradiation , Protocoles cliniques
5.
Curr Oncol ; 30(7): 7073-7088, 2023 07 24.
Article de Anglais | MEDLINE | ID: mdl-37504373

RÉSUMÉ

AIM: The gold standard of care for pancreatic adenocarcinoma is the integrated treatment of surgery and chemotherapy (ChT), but about 50% of patients present with unresectable disease. Our study evaluated the efficacy in terms of local control, survival and safety of stereotactic body radiation therapy (SBRT) in locally advanced pancreatic cancer (LAPC). METHODS: A retrospective study (STEP study) analyzed patients with LAPC treated with a dose of 45 Gy in 6 fractions. Local control (LC), distant progression free survival (DPFS), overall survival (OS) and toxicity were analyzed according to the Kaplan-Meier method. RESULTS: A total of 142 patients were evaluated. Seventy-six patients (53.5%) received induction ChT before SBRT. The median follow-up was 11 months. One-, 2- and 3-year LC rate was 81.9%, 69.1% and 58.5%. Median DPFS was 6.03 months; 1- and 2-year DPFS rate was 19.9% and 4.5%. Median OS was 11.6 months and 1-, 2- and 3-year OS rates were 45.4%, 16.1%, and 9.8%. At univariate analysis, performed by the log-rank test, age < 70 years (p = 0.037), pre-SBRT ChT (p = 0.004) and post-SBRT ChT (p = 0.019) were associated with better OS. No patients experienced G3 toxicity. CONCLUSION: SBRT represents an effective and safe therapeutic option in the multimodal treatment of patients with LAPC in terms of increased LC. When SBRT was sequentially integrated with ChT, the treatment proved to be promising in terms of OS as well.


Sujet(s)
Adénocarcinome , Tumeurs du pancréas , Radiochirurgie , Humains , Sujet âgé , Pronostic , Radiochirurgie/effets indésirables , Radiochirurgie/méthodes , Adénocarcinome/anatomopathologie , Études rétrospectives , Tumeurs du pancréas
6.
Curr Oncol ; 30(4): 4067-4077, 2023 04 06.
Article de Anglais | MEDLINE | ID: mdl-37185422

RÉSUMÉ

Total marrow (lymph node) irradiation (TMI/TMLI) delivery requires more time than standard radiotherapy treatments. The patient's extremities, through the joints, can experience large movements. The reproducibility of TMI/TMLI patients' extremities was evaluated to find the best positioning and reduce unwanted movements. Eighty TMI/TMLI patients were selected (2013-2022). During treatment, a cone-beam computed tomography (CBCT) was performed for each isocenter to reposition the patient. CBCT-CT pairs were evaluated considering: (i) online vector shift (OVS) that matched the two series; (ii) residual vector shift (RVS) to reposition the patient's extremities; (iii) qualitative agreement (range 1-5). Patients were subdivided into (i) arms either leaning on the frame or above the body; (ii) with or without a personal cushion for foot positioning. The Mann-Whitney test was considered (p < 0.05 significant). Six-hundred-twenty-nine CBCTs were analyzed. The median OVS was 4.0 mm, with only 1.6% of cases ranked < 3, and 24% of RVS > 10 mm. Arms leaning on the frame had significantly smaller RVS than above the body (median: 8.0 mm/6.0 mm, p < 0.05). Using a personal cushion for the feet significantly improved the RVS than without cushions (median: 8.5 mm/1.8 mm, p < 0.01). The role and experience of the radiotherapy team are fundamental to optimizing the TMI/TMLI patient setup.


Sujet(s)
Moelle osseuse , Radiothérapie conformationnelle avec modulation d'intensité , Humains , Moelle osseuse/effets des radiations , Reproductibilité des résultats , Radiothérapie conformationnelle avec modulation d'intensité/méthodes , Dosimétrie en radiothérapie , Planification de radiothérapie assistée par ordinateur/méthodes , Membres
7.
J Appl Clin Med Phys ; 24(6): e13931, 2023 Jun.
Article de Anglais | MEDLINE | ID: mdl-37085997

RÉSUMÉ

PURPOSE: To assess the impact of the planner's experience and optimization algorithm on the plan quality and complexity of total marrow and lymphoid irradiation (TMLI) delivered by means of volumetric modulated arc therapy (VMAT) over 2010-2022 at our institute. METHODS: Eighty-two consecutive TMLI plans were considered. Three complexity indices were computed to characterize the plans in terms of leaf gap size, irregularity of beam apertures, and modulation complexity. Dosimetric points of the target volume (D2%) and organs at risk (OAR) (Dmean) were automatically extracted to combine them with plan complexity and obtain a global quality score (GQS). The analysis was stratified based on the different optimization algorithms used over the years, including a knowledge-based (KB) model. Patient-specific quality assurance (QA) using Portal Dosimetry was performed retrospectively, and the gamma agreement index (GAI) was investigated in conjunction with plan complexity. RESULTS: Plan complexity significantly reduced over the years (r = -0.50, p < 0.01). Significant differences in plan complexity and plan dosimetric quality among the different algorithms were observed. Moreover, the KB model allowed to achieve significantly better dosimetric results to the OARs. The plan quality remained similar or even improved during the years and when moving to a newer algorithm, with GQS increasing from 0.019 ± 0.002 to 0.025 ± 0.003 (p < 0.01). The significant correlation between GQS and time (r = 0.33, p = 0.01) indicated that the planner's experience was relevant to improve the plan quality of TMLI plans. Significant correlations between the GAI and the complexity metrics (r = -0.71, p < 0.01) were also found. CONCLUSION: Both the planner's experience and algorithm version are crucial to achieve an optimal plan quality in TMLI plans. Thus, the impact of the optimization algorithm should be carefully evaluated when a new algorithm is introduced and in system upgrades. Knowledge-based strategies can be useful to increase standardization and improve plan quality of TMLI treatments.


Sujet(s)
Moelle osseuse , Radiothérapie conformationnelle avec modulation d'intensité , Humains , Moelle osseuse/effets des radiations , Radiothérapie conformationnelle avec modulation d'intensité/méthodes , Études rétrospectives , Irradiation ganglionnaire , Dosimétrie en radiothérapie , Planification de radiothérapie assistée par ordinateur/méthodes , Organes à risque/effets des radiations
8.
Curr Oncol ; 30(3): 3344-3354, 2023 03 13.
Article de Anglais | MEDLINE | ID: mdl-36975467

RÉSUMÉ

BACKGROUND: Radiotherapy is essential in the management of head-neck cancer. During the course of radiotherapy, patients may develop significant anatomical changes. Re-planning with adaptive radiotherapy may ensure adequate dose coverage and sparing of organs at risk. We investigated the consequences of adaptive radiotherapy on head-neck cancer patients treated with volumetric-modulated arc radiation therapy compared to simulated non-adaptive plans: Materials and methods: We included in this retrospective dosimetric analysis 56 patients treated with adaptive radiotherapy. The primary aim of the study was to analyze the dosimetric differences with and without an adaptive approach for targets and organs at risk, particularly the spinal cord, parotid glands, oral cavity and larynx. The original plan (OPLAN) was compared to the adaptive plan (APLAN) and to a simulated non-adaptive dosimetric plan (DPLAN). RESULTS: The non-adaptive DPLAN, when compared to OPLAN, showed an increased dose to all organs at risk. Spinal cord D2 increased from 27.91 (21.06-31.76) Gy to 31.39 (27.66-38.79) Gy (p = 0.00). V15, V30 and V45 of the DPLAN vs. the OPLAN increased by 20.6% (p = 0.00), 14.78% (p = 0.00) and 15.55% (p = 0.00) for right parotid; and 16.25% (p = 0.00), 18.7% (p = 0.00) and 20.19% (p = 0.00) for left parotid. A difference of 36.95% was observed in the oral cavity V40 (p = 0.00). Dose coverage was significantly reduced for both CTV (97.90% vs. 99.96%; p = 0.00) and PTV (94.70% vs. 98.72%; p = 0.00). The APLAN compared to the OPLAN had similar values for all organs at risk. CONCLUSIONS: The adaptive strategy with re-planning is able to avoid an increase in dose to organs at risk and better target coverage in head-neck cancer patients, with potential benefits in terms of side effects and disease control.


Sujet(s)
Tumeurs de la tête et du cou , Radiothérapie conformationnelle avec modulation d'intensité , Humains , Organes à risque/effets des radiations , Dosimétrie en radiothérapie , Études rétrospectives , Planification de radiothérapie assistée par ordinateur , Tumeurs de la tête et du cou/radiothérapie , Tumeurs de la tête et du cou/étiologie , Radiothérapie conformationnelle avec modulation d'intensité/effets indésirables
9.
Cancers (Basel) ; 15(5)2023 Feb 22.
Article de Anglais | MEDLINE | ID: mdl-36900186

RÉSUMÉ

The aim of this study was to evaluate the clinical outcomes of a large series of brain metastatic renal cell carcinoma (BMRCC) patients treated in three Italian centers. METHODS: A total of 120 BMRCC patients with a total of 176 lesions treated were evaluated. Patients received surgery plus postoperative HSRS, single-fraction SRS, or hypofractionated SRS (HSRS). Local control (LC), brain distant failure (BDF), overall survival (OS), toxicities, and prognostic factors were assessed. RESULTS: The median follow-up time was 77 months (range 16-235 months). Surgery plus HSRS was performed in 23 (19.2%) cases, along with SRS in 82 (68.3%) and HSRS in 15 (12.5%). Seventy-seven (64.2%) patients received systemic therapy. The main total dose and fractionation used were 20-24 Gy in single fraction or 32-30 Gy in 4-5 daily fractions. Median LC time and 6 month and 1, 2 and 3 year LC rates were nr, 100%, 95.7% ± 1.8%, 93.4% ± 2.4%, and 93.4% ± 2.4%. Median BDF time and 6 month and 1, 2 and 3 year BDF rates were n.r., 11.9% ± 3.1%, 25.1% ± 4.5%, 38.7% ± 5.5%, and 44.4% ± 6.3%, respectively. Median OS time and 6 month and 1, 2 and 3 year OS rates were 16 months (95% CI: 12-22), 80% ± 3.6%, 58.3% ± 4.5%, 30.9% ± 4.3%, and 16.9% ± 3.6, respectively. No severe neurological toxicities occurred. Patients with a favorable/intermediate IMDC score, a higher RCC-GPA score, an early occurrence of BMs from primary diagnosis, absence of EC metastases, and a combined local treatment (surgery plus adjuvant HSRS) had a better outcome. CONCLUSIONS: SRS/HSRS is proven to be an effective local treatment for BMRCC. A careful evaluation of prognostic factors is a valid step to manage the optimal therapeutic strategy for BMRCC patients.

10.
Cancers (Basel) ; 15(5)2023 Feb 28.
Article de Anglais | MEDLINE | ID: mdl-36900326

RÉSUMÉ

BACKGROUND: The total marrow and lymph node irradiation (TMLI) target includes the bones, spleen, and lymph node chains, with the latter being the most challenging structures to contour. We evaluated the impact of introducing internal contour guidelines to reduce the inter- and intraobserver lymph node delineation variability in TMLI treatments. METHODS: A total of 10 patients were randomly selected from our database of 104 TMLI patients so as to evaluate the guidelines' efficacy. The lymph node clinical target volume (CTV_LN) was recontoured according to the guidelines (CTV_LN_GL_RO1) and compared to the historical guidelines (CTV_LN_Old). Both topological (i.e., Dice similarity coefficient (DSC)) and dosimetric (i.e., V95 (the volume receiving 95% of the prescription dose) metrics were calculated for all paired contours. RESULTS: The mean DSCs were 0.82 ± 0.09, 0.97 ± 0.01, and 0.98 ± 0.02, respectively, for CTV_LN_Old vs. CTV_LN_GL_RO1, and between the inter- and intraobserver contours following the guidelines. Correspondingly, the mean CTV_LN-V95 dose differences were 4.8 ± 4.7%, 0.03 ± 0.5%, and 0.1 ± 0.1%. CONCLUSIONS: The guidelines reduced the CTV_LN contour variability. The high target coverage agreement revealed that historical CTV-to-planning-target-volume margins were safe, even if a relatively low DSC was observed.

11.
Radiat Oncol ; 18(1): 28, 2023 Feb 07.
Article de Anglais | MEDLINE | ID: mdl-36750848

RÉSUMÉ

BACKGROUND: Comparative prospective data regarding different radiosurgery (SRS) modalities for treating brain metastases (BMs) from solid tumors are not available. To investigate with a single institute phase III randomized trial whether SRS executed with linac (Arm-B) is superior to a dedicated multi-source gamma-ray stereotactic platform (Arm-A). METHODS: Adults patients with 1-4 BMs from solid tumors up to 30 mm in maximum diameter were randomly assigned to arms A and B. The primary endpoint was cumulative incidence of symptomatic (grade 2-3) radionecrosis (CIRN). Secondary endpoints were local progression cumulative incidence (CILP), distant brain failure, disease-free survival (DFS), and overall survival (OS). RESULTS: A total of 251 patients were randomly assigned to Arm-A (121) or Arm-B (130). The 1-year RN cumulative incidence was 6.7% in whole cohort, 3.8% (95% CI 1.9-7.4%) in Arm-B, and 9.3% (95% CI 6.2-13.8%) in the Arm-A (p = 0.43). CIRN was influenced by target volume irradiated only for the Arm-A (p << 0.001; HR 1.36 [95% CI 1.25-1.48]). Symptomatic RN occurred in 56 cases at a median time of 10.3 months (range 1.15-54.8 months), 27 in the Arm-B at a median time of 15.9 months (range 4.9-54.8 months), and 29 in the Arm-A at a median time of 6.9 months (1.2-32.3 months), without statistically significant differences between the two arms. No statistically significant differences were recorded between the two arms in CILP, BDF, DFS or OS. The mean beam-on time to deliver SRS was 49.0 ± 36.2 min in Arm-A, and 3.1 ± 1.6 min in Arm-B. CONCLUSIONS: Given the technical differences between the treatment platforms investigated in this single-institution study, linac-based SRS (Arm-B) did not lead to significantly lower grade 2-3 RN rates versus the multi-source gamma-ray system (Arm-A) in a population of patients with limited brain metastases of small volume. No significant difference in local control was observed between both arms. For Arm-B, the treatment delivery time was significantly lower than for Arm-A. TRIAL REGISTRATION: ClinicalTrials.gov Identifier NCT02355613.


Sujet(s)
Tumeurs du cerveau , Radiochirurgie , Adulte , Humains , Radiochirurgie/méthodes , Études prospectives , Études rétrospectives , Tumeurs du cerveau/secondaire , Survie sans progression , Résultat thérapeutique
12.
Strahlenther Onkol ; 199(4): 412-419, 2023 04.
Article de Anglais | MEDLINE | ID: mdl-36326856

RÉSUMÉ

PURPOSE: Total marrow (and lymphoid) irradiation (TMI-TMLI) is limited by the couch travel range of modern linacs, which forces the treatment delivery to be split into two plans with opposite orientations: a head-first supine upper-body plan, and a feet-first supine lower extremities plan. A specific field junction is thus needed to obtain adequate target coverage in the overlap region of the two plans. In this study, an automatic procedure was developed for field junction creation and lower extremities plan optimization. METHODS: Ten patients treated with TMI-TMLI at our institution were selected retrospectively. The planning of the lower extremities was performed automatically. Target volume parameters (CTV_J­V98% > 98%) at the junction region and several dose statistics (D98%, Dmean, and D2%) were compared between automatic and manual plans. The modulation complexity score (MCS) was used to assess plan complexity. RESULTS: The automatic procedure required 60-90 min, depending on the case. All automatic plans achieved clinically acceptable dosimetric results (CTV_J­V98% > 98%), with significant differences found at the junction region, where Dmean and D2% increased on average by 2.4% (p < 0.03) and 3.0% (p < 0.02), respectively. Similar plan complexity was observed (median MCS = 0.12). Since March 2022, the automatic procedure has been introduced in our clinic, reducing the TMI-TMLI simulation-to-delivery schedule by 2 days. CONCLUSION: The developed procedure allowed treatment planning of TMI-TMLI to be streamlined, increasing efficiency and standardization, preventing human errors, while maintaining the dosimetric plan quality and complexity of manual plans. Automated strategies can simplify the future adoption and clinical implementation of TMI-TMLI treatments in new centers.


Sujet(s)
Moelle osseuse , Radiothérapie conformationnelle avec modulation d'intensité , Humains , Moelle osseuse/effets des radiations , Radiothérapie conformationnelle avec modulation d'intensité/méthodes , Études rétrospectives , Dosimétrie en radiothérapie , Organes à risque/effets des radiations , Planification de radiothérapie assistée par ordinateur/méthodes , Membre inférieur
13.
Radiat Oncol ; 17(1): 200, 2022 Dec 06.
Article de Anglais | MEDLINE | ID: mdl-36474297

RÉSUMÉ

BACKGROUND: To analyze RapidPlan knowledge-based models for DVH estimation of organs at risk from breast cancer VMAT plans presenting arc sectors en-face to the breast with zero dose rate, feature imposed during the optimization phase (avoidance sectors AS). METHODS: CT datasets of twenty left breast patients in deep-inspiration breath-hold were selected. Two VMAT plans, PartArc and AvoidArc, were manually generated with double arcs from ~ 300 to ~ 160°, with the second having an AS en-face to the breast to avoid contralateral breast and lung direct irradiation. Two RapidPlan models were generated from the two plan sets. The two models were evaluated in a closed loop to assess the model performance on plans where the AS were selected or not in the optimization. RESULTS: The PartArc plans model estimated DVHs comparable with the original plans. The AvoidArc plans model estimated a DVH pattern with two steps for the contralateral structures when the plan does not contain the AS selected in the optimization phase. This feature produced mean doses of the contralateral breast, averaged over all patients, of 0.4 ± 0.1 Gy, 0.6 ± 0.2 Gy, and 1.1 ± 0.2 Gy for the AvoidArc plan, AvoidArc model estimation, RapidPlan generated plan, respectively. The same figures for the contralateral lung were 0.3 ± 0.1 Gy, 1.6 ± 0.6 Gy, and 1.2 ± 0.5 Gy. The reason was found in the possible incorrect information extracted from the model training plans due to the lack of knowledge about the AS. Conversely, in the case of plans with AS set in the optimization generated with the same AvoidArc model, the estimated and resulting DVHs were comparable. Whenever the AvoidArc model was used to generate DVH estimation for a plan with AS, while the optimization was made on the plan without the AS, the optimizer evidentiated the limitation of a minimum dose rate of 0.2 MU/°, resulting in an increased dose to the contralateral structures respect to the estimation. CONCLUSIONS: The RapidPlan models for breast planning with VMAT can properly estimate organ at risk DVH. Attention has to be paid to the plan selection and usage for model training in the presence of avoidance sectors.

14.
Radiat Oncol ; 17(1): 150, 2022 Aug 26.
Article de Anglais | MEDLINE | ID: mdl-36028862

RÉSUMÉ

BACKGROUND: To investigate the performance of a narrow-scope knowledge-based RapidPlan (RP) model for optimisation of intensity-modulated proton therapy (IMPT) and volumetric modulated arc therapy (VMAT) plans applied to patients with pleural mesothelioma. Second, estimate the potential benefit of IMPT versus VMAT for this class of patients. METHODS: A cohort of 82 patients was retrospectively selected; 60 were used to "train" a dose-volume histogram predictive model; the remaining 22 provided independent validation. The performance of the RP models was benchmarked, comparing predicted versus achieved mean and near-to-maximum dose for all organs at risk (OARs) in the training set and by quantitative assessment of some dose-volume metrics in the comparison of the validation RP-based data versus the manually optimised training datasets. Treatment plans were designed for a prescription dose of 44 Gy in 22 fractions (proton doses account for a fixed relative biological effectiveness RBE = 1.1). RESULTS: Training and validation RP-based plans resulted dosimetrically similar for both VMAT and IMPT groups, and the clinical planning aims were met for all structures. The IMPT plans outperformed the VMAT ones for all OARs for the contra-lateral and the mean and low dose regions for the ipsilateral OARs. Concerning the prediction performance of the RP models, the linear regression for the near-to-maximum dose resulted in Dachieved = 1.03Dpredicted + 0.58 and Dachieved = 1.02Dpredicted + 1.46 for VMAT and IMPT, respectively. For the mean dose it resulted: Dachieved = 0.99Dpredicted + 0.34 and Dachieved = 1.05Dpredicted + 0.27 respectively. In both cases, the linear correlation between prediction and achievement is granted with an angular coefficient deviating from unity for less than 5%. Concerning the dosimetric comparison between manual plans in the training cohort and RP-based plans in the validation cohort, no clinical differences were observed for the target volumes in both the VMAT and IMPT groups. Similar consistency was observed for the dose-volume metrics analysed for the OAR. This proves the possibility of achieving the same quality of plans with manual procedures (the training set) or with automated RP-based methods (the validation set). CONCLUSION: Two models were trained and validated for VMAT and IMPT plans for pleural mesothelioma. The RP model performance resulted satisfactory as measured by the agreement between predicted and achieved (after full optimisation) dose-volume metrics. The IMPT plans outperformed the VMAT plans for all the OARs (with different intensities for contra- or ipsilateral structures). RP-based planning enabled the automation of part of the optimisation and the harmonisation of the dose-volume results between training and validation. The IMPT data showed a systematic significant dosimetric advantage over VMAT. In general, using an RP-based approach can simplify the optimisation workflow in these complex treatment indications without impacting the quality of plans.


Sujet(s)
Mésothéliome , Protonthérapie , Radiothérapie conformationnelle avec modulation d'intensité , Humains , Organes à risque , Protons , Dosimétrie en radiothérapie , Planification de radiothérapie assistée par ordinateur , Études rétrospectives
15.
Curr Oncol ; 29(7): 4893-4901, 2022 07 12.
Article de Anglais | MEDLINE | ID: mdl-35877248

RÉSUMÉ

BACKGROUND: This study evaluated the outcome, toxicity and predictive factors in patients unfit for concurrent chemo-radiotherapy (CT-RT) treated with hypofractionated sequential CT-RT or exclusive radiotherapy (RT) for locally advanced non-small cell lung cancer (LA-NSCLC). METHODS: We included patients affected by LA-NSCLC (stage IIA-IVA) treated with a total dose of 50-60 Gy in 20 fractions. The primary outcomes were local control (LC), distant metastasis-free survival (DMFS), progression-free survival (PFS) and overall survival (OS). Univariate analysis was used to correlate outcomes with prognostic factors. RESULTS: Between 2011 and 2019, 210 patients were treated, 113 (53.8%) with sequential CT-RT and 97 (46.2%) with exclusive RT. After a median follow-up of 15.3 months, 74 patients (35.2%) had a local progression and 133 (63.3%) had a distant progression. The one-, two- and five-year LC were 73.6%, 55.3% and 47.9%, respectively. At the time of analysis, 167 patients (79.5%) died. The one-, two- and five-year OS were 64.7%, 36% and 20%, respectively. PTV volume correlated with PFS (p = 0.001) and LC (p = 0.005). Acute and late toxicity occurred in 82% and 26% of patients. CONCLUSIONS: Albeit with the known limitations of a retrospective and heterogeneous study, our work shows that hypofractionated sequential CT-RT or exclusive RT offer a good local control and toxicity profile and a promising survival rate in LA-NSCLC patients unfit for the concurrent CT-RT scheme.


Sujet(s)
Carcinome pulmonaire non à petites cellules , Tumeurs du poumon , Radiothérapie conformationnelle avec modulation d'intensité , Carcinome pulmonaire non à petites cellules/traitement médicamenteux , Humains , Tumeurs du poumon/traitement médicamenteux , Études rétrospectives , Taux de survie
16.
Strahlenther Onkol ; 198(8): 710-718, 2022 08.
Article de Anglais | MEDLINE | ID: mdl-35059760

RÉSUMÉ

OBJECTIVE: The present study aimed to investigate if CT-based radiomics features could correlate to the risk of metastatic progression in high-risk prostate cancer patients treated with radical RT and long-term androgen deprivation therapy (ADT). MATERIALS AND METHODS: A total of 157 patients were investigated and radiomics features extracted from the contrast-free treatment planning CT series. Three volumes were segmented: the prostate gland only (CTV_p), the prostate gland with seminal vesicles (CTV_psv), and the seminal vesicles only (CTV_sv). The patients were split into two subgroups of 100 and 57 patients for training and validation. Five clinical and 62 radiomics features were included in the analysis. Considering metastases-free survival (MFS) as an endpoint, the predictive model was used to identify the subgroups with favorable or unfavorable prognoses (separated by a threshold selected according to the Youden method). Pure clinical, pure radiomic, and combined predictive models were investigated. RESULTS: With a median follow-up of 30.7 months, the MFS at 1 and 3 years was 97.2% ± 1.5 and 92.1% ± 2.0, respectively. Univariate analysis identified seven potential predictors for MFS in the CTV_p group, 11 in the CTV_psv group, and 9 in the CTV_sv group. After elastic net reduction, these were 4 predictors for MFS in the CTV_p group (positive lymph nodes, Gleason score, H_Skewness, and NGLDM_Contrast), 5 in the CTV_psv group (positive lymph nodes, Gleason score, H_Skewnesss, Shape_Surface, and NGLDM_Contrast), and 6 in the CTV_sv group (positive lymph nodes, Gleason score, H_Kurtosis, GLCM_Correlation, GLRLM_LRHGE, and GLZLM_SZLGE). The patients' group of the training and validation cohorts were stratified into favorable and unfavorable prognosis subgroups. For the combined model, for CTV_p, the mean MFS was 134 ± 14.5 vs. 96.9 ± 22.2 months for the favorable and unfavorable subgroups, respectively, and 136.5 ± 14.6 vs. 70.5 ± 4.3 months for CTV_psv and 150.0 ± 4.2 vs. 91.1 ± 8.6 months for CTV_sv, respectively. CONCLUSION: Radiomic features were able to predict the risk of metastatic progression in high-risk prostate cancer. Combining the radiomic features and clinical characteristics can classify high-risk patients into favorable and unfavorable prognostic groups.


Sujet(s)
Tumeurs de la prostate , Antagonistes des androgènes , Humains , Mâle , Pronostic , Prostate/anatomopathologie , Tumeurs de la prostate/imagerie diagnostique , Tumeurs de la prostate/anatomopathologie , Tumeurs de la prostate/radiothérapie , Vésicules séminales/anatomopathologie
17.
J Cancer Res Clin Oncol ; 147(12): 3619-3625, 2021 Dec.
Article de Anglais | MEDLINE | ID: mdl-34537907

RÉSUMÉ

PURPOSE: The purpose of this study was to assess prospectively the efficacy and safety of stereotactic body radiation therapy (SBRT) for adrenal gland metastasis, with a focus on the assessment of the irradiated subjects' endocrinological function. MATERIALS AND METHODS: A total of 36 patients were enrolled from 2017 to 2020 in this prospective phase II trial. Patients were treated with Linac-based SBRT, with a dose of 45 Gy in 3 consecutive fractions. Primary end-point was local control (LC) of the treated lesions and secondary end-points included evaluation of acute and late toxicity, progression free survival (PFS), overall survival (OS) and the impact on the hormonal production of adrenal glands. RESULTS: With a median follow-up of 9.5 months, LC rates at 1 and 2 years were 94.7% and 88.4%, respectively. Rates of PFS at 1 and 2 years were 50.5% and 29.8%, with a median PFS of 14.7 months. Rates of OS at 1 and 2 years were 62.9% and 44.1%. At univariate analysis, oligorecurrence was associated with better OS compared to oligoprogressive or synchronous metastatic disease. No grade 3 or greater toxicities were registered and only a minority of patients (22.2%) reported mild treatment-related side effects. Hormonal and electrolytes production was assessed before and after treatment, showing only a slight and transient variation within the reference ranges. CONCLUSION: SBRT on adrenal metastases has been confirmed to be a feasible and effective treatment. With an excellent disease control and the preservation of the endocrine function, SBRT with ablative dose can be considered a viable alternative to more invasive approaches.


Sujet(s)
Tumeurs de la surrénale/radiothérapie , Tumeurs de la surrénale/secondaire , Radiochirurgie/méthodes , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Adulte d'âge moyen , Survie sans progression , Études prospectives , Résultat thérapeutique
18.
Cancers (Basel) ; 13(15)2021 Jul 30.
Article de Anglais | MEDLINE | ID: mdl-34359737

RÉSUMÉ

Dosiomics is a texture analysis method to produce dose features that encode the spatial 3D distribution of radiotherapy dose. Dosiomic studies, in a multicentre setting, require assessing the features' stability to dose calculation settings and the features' capability in distinguishing different dose distributions. Dose distributions were generated by eight Italian centres on a shared image dataset acquired on a dedicated phantom. Treatment planning protocols, in terms of planning target volume coverage and dose-volume constraints to the organs at risk, were shared among the centres to produce comparable dose distributions for measuring reproducibility/stability and sensitivity of dosiomic features. In addition, coefficient of variation (CV) was employed to evaluate the dosiomic features' variation. We extracted 38,160 features from 30 different dose distributions from six regions of interest, grouped by four features' families. A selected group of features (CV < 3 for the reproducibility/stability studies, CV > 1 for the sensitivity studies) were identified to support future multicentre studies, assuring both stable features when dose distributions variation is minimal and sensitive features when dose distribution variations need to be clearly identified. Dosiomic is a promising tool that could support multicentre studies, especially for predictive models, and encode the spatial and statistical characteristics of the 3D dose distribution.

19.
Phys Med ; 88: 98-103, 2021 Aug.
Article de Anglais | MEDLINE | ID: mdl-34217003

RÉSUMÉ

PURPOSE: The influence of basic plan parameters such as slice thickness, grid resolution, algorithm type and field size on calculated small field output factors (OFs) was evaluated in a multicentric study. METHODS AND MATERIALS: Three computational homogeneous water phantoms with slice thicknesses (ST) 1, 2 and 3 mm were shared among twenty-one centers to calculate OFs for 1x1, 2x2 and 3x3 cm2 field sizes (FSs) (normalized to 10x10 cm2 FS), with their own treatment planning system (TPS) and the energy clinically used for stereotactic body radiation therapy delivery. OFs were calculated for each combination of grid resolution (GR) (1, 2 and 3 mm) and ST and finally compared with the OFs measured for the TPS commissioning. A multivariate analysis was performed to test the effect of basic plan parameters on calculated OFs. RESULTS: A total of 509 data points were collected. Calculated OFs are slightly higher than measured ones. The multivariate analysis showed that Center, GR, algorithm type, and FS are predictive variables of the difference between calculated and measured OFs (p < 0.001). As FS decreases, the spread in the difference between calculated and measured OFs became larger when increasing the GR. Monte Carlo and Analytical Anisotropic Algorithms, presented a dependence on GR (p < 0.01), while Collapsed Cone Convolution and Acuros did not. The effect of the ST was found to be negligible. CONCLUSIONS: Modern TPSs slightly overestimate the calculated small field OFs compared with measured ones. Grid resolution, algorithm, center number and field size influence the calculation of small field OFs.


Sujet(s)
Radiochirurgie , Planification de radiothérapie assistée par ordinateur , Algorithmes , Méthode de Monte Carlo , Fantômes en imagerie , Dosimétrie en radiothérapie
20.
Rep Pract Oncol Radiother ; 26(1): 101-110, 2021.
Article de Anglais | MEDLINE | ID: mdl-34046220

RÉSUMÉ

BACKGROUND: The purpose of the study was to evaluate the toxicity and outcome of nasopharyngeal carcinoma patients treated using 3-dimensional conformal radiotherapy (3DCRT) or volumetric modulated arc therapy (VMAT) technique. MATERIALS AND METHODS: 68 patients treated between 2006 and 2018 were retrospectively analysed. Since 2009 patients received 3DCRT with 50/70 Gy to the elective/boost volumes in 35 fractions; from then, VMAT with simultaneous integrated boost (SIB) with 54.45/69.96 Gy in 33, or 54/66 Gy in 30 fractions. Induction chemotherapy was administered in 74% of the patients, concomitant cisplatinum in 87%. Acute and late toxicity data, progression-free survival PSF and overall survival OS, and toxicity correlations with dose metrics were reported. RESULTS: With a median follow-up of 64 months, complete remission at the last evaluation was in 68% of the patients, while 28% and 9% had locoregional relapse and distant disease, respectively. The 5- and 10-year progression free survival (PFS) rates were 62.7 ± 6.5% and 53.2 ± 8.7%, respectively. The 5- and 10-year OS rates were 78.9 ± 5.5% and 61.4 ± 9.2%, respectively. At the multivariate Cox analysis TNM stage (p = 0.02) and concomitant chemotherapy (p = 0.01) resulted significant for PFS, concomitant chemotherapy (p = 0.04) for OS.Improvements in acute toxicity were presented for VMAT patients due to its ability to spare OARs. Odds ratio (OR) for acute salivary toxicity, between VMAT and 3DCRT, was 4.67 (p = 0.02). Dosimetrically, salivary toxicity correlated with mean parotid dose (p = 0.05), dysphagia with laryngeal (p = 0.04) and mean oral cavity (p = 0.06) doses, when dose-volume histograms (DVHs) are corrected for fractionation. CONCLUSION: This study is a proof of a significant benefit of the VMAT technique compared with 3DCRT in terms of side effects in nasopharynx patients, and adds dosimetric correlations.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...