Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 6 de 6
Filtrer
1.
Nucl Instrum Methods Phys Res A ; 1043: 167464, 2022 Nov 11.
Article de Anglais | MEDLINE | ID: mdl-36345417

RÉSUMÉ

Owing to the favorable depth-dose distribution and the radiobiological properties of heavy ion radiation, ion beam therapy shows an improved success/toxicity ratio compared to conventional radiotherapy. The sharp dose gradients and very high doses in the Bragg peak region, which represent the larger physical advantage of ion beam therapy, make it also extremely sensitive to range uncertainties. The use of ß +-radioactive ion beams would be ideal for simultaneous treatment and accurate online range monitoring through PET imaging. Since all the unfragmented primary ions are potentially contributing to the PET signal, these beams offer an improved image quality while preserving the physical and radiobiological advantages of the stable counterparts. The challenging production of radioactive ion beams and the difficulties in reaching high intensities, have discouraged their clinical application. In this context, the project Biomedical Applications of Radioactive ion Beams (BARB) started at GSI (Helmholtzzentrum für Schwerionenforschung GmbH) with the main goal to assess the technical feasibility and investigate possible advantages of radioactive ion beams on the pre-clinical level. During the first experimental campaign 11C and 10C beams were produced and isotopically separated with the FRagment Separator (FRS) at GSI. The ß +-radioactive ion beams were produced with a beam purity of 99% for all the beam investigated (except one case where it was 94%) and intensities potentially sufficient to treat a small animal tumors within few minutes of irradiation time, ∼ 106 particle per spill for the 10C and ∼ 107 particle per spill for the 11C beam, respectively. The impact of different ion optical parameters on the depth dose distribution was studied with a precision water column system. In this work, the measured depth dose distributions are presented together with results from Monte Carlo simulations using the FLUKA software.

2.
Radiat Res ; 198(2): 107-119, 2022 08 01.
Article de Anglais | MEDLINE | ID: mdl-35930014

RÉSUMÉ

Galactic cosmic rays (GCR) are among the main deterrents to manned space exploration. Currently, the most realistic way to reduce the dangers caused by GCR to acceptable levels is passive shielding. Light materials guarantee the strongest dose attenuation per unit mass. High-density polyethylene is considered the gold standard for radiation protection in space. Nevertheless, accelerator-based experimental campaigns already showed the advantages of more hydrogen-rich innovative shielding materials such as lithium hydride. The experimental campaigns of this work focused on the absorbed dose attenuation properties of lithium-based hydrides chemically stabilized with a paraffin matrix. Such materials were compared to pure lithium-based hydrides, polyethylene, structural materials such as spacecraft aluminum alloys and lithium batteries, and in situ shielding materials such as Moon regolith and its main components silicon and silicon dioxide. The experimental results were compared to simulations performed with PHITS, FLUKA, and Geant4, which are among the most used Monte Carlo codes for radiation protection in space. The simulations showed systematic differences and highlighted the pressing need for reliable nuclear cross-section models.


Sujet(s)
Rayonnement cosmique , Radioprotection , Vol spatial , Rayonnement cosmique/effets indésirables , Lithium , Méthode de Monte Carlo , Dose de rayonnement , Radioprotection/méthodes
3.
Front Oncol ; 12: 830080, 2022.
Article de Anglais | MEDLINE | ID: mdl-35402273

RÉSUMÉ

Fiducial markers are used for image guidance to verify the correct positioning of the target for the case of tumors that can suffer interfractional motion during proton therapy. The markers should be visible on daily imaging, but at the same time, they should produce minimal streak artifacts in the CT scans for treatment planning and induce only slight dose perturbations during particle therapy. In this work, these three criteria were experimentally investigated at the Heidelberg Ion Beam Therapy Center. Several small fiducial markers with different geometries and materials (gold, platinum, and carbon-coated ZrO2) were evaluated. The streak artifacts on treatment planning CT were measured with and without iMAR correction, showing significantly smaller artifacts from markers lighter than 6 mg and a clear improvement with iMAR correction. Daily imaging as X-ray projections and in-room mobile CT were also performed. Markers heavier than 6 mg showed a better contrast in the X-ray projections, whereas on the images from the in-room mobile CT, all markers were clearly visible. In the other part of this work, fluence perturbations of proton beams were measured for the same markers by using a tracker system of several high spatial resolution CMOS pixel sensors. The measurements were performed for single-energy beams, as well as for a spread-out Bragg peak. Three-dimensional fluence distributions were computed after reconstructing all particle trajectories. These measurements clearly showed that the ZrO2 markers and the low-mass gold/platinum markers (0.35mm diameter) induce perturbations being 2-3 times lower than the heavier gold or platinum markers of 0.5mm diameter. Monte Carlo simulations, using the FLUKA code, were used to compute dose distributions and showed good agreement with the experimental data after adjusting the phase space of the simulated proton beam compared to the experimental beam.

4.
Front Oncol ; 11: 737050, 2021.
Article de Anglais | MEDLINE | ID: mdl-34504803

RÉSUMÉ

Several techniques are under development for image-guidance in particle therapy. Positron (ß+) emission tomography (PET) is in use since many years, because accelerated ions generate positron-emitting isotopes by nuclear fragmentation in the human body. In heavy ion therapy, a major part of the PET signals is produced by ß+-emitters generated via projectile fragmentation. A much higher intensity for the PET signal can be obtained using ß+-radioactive beams directly for treatment. This idea has always been hampered by the low intensity of the secondary beams, produced by fragmentation of the primary, stable beams. With the intensity upgrade of the SIS-18 synchrotron and the isotopic separation with the fragment separator FRS in the FAIR-phase-0 in Darmstadt, it is now possible to reach radioactive ion beams with sufficient intensity to treat a tumor in small animals. This was the motivation of the BARB (Biomedical Applications of Radioactive ion Beams) experiment that is ongoing at GSI in Darmstadt. This paper will present the plans and instruments developed by the BARB collaboration for testing the use of radioactive beams in cancer therapy.

5.
Phys Med Biol ; 65(8): 085005, 2020 04 17.
Article de Anglais | MEDLINE | ID: mdl-32053811

RÉSUMÉ

Fiducial markers are nowadays a common tool for patient positioning verification before radiotherapy treatment. These markers should be visible on x-ray projection imaging, produce low streak artifacts on CTs and induce small dose perturbations due to edge-scattering effects during the ion-beam therapy treatment. In this study, the latter effect was investigated and the perturbations created by the markers were evaluated with a new measurement method using a tracker system composed of six CMOS pixel sensors. The present method enables the determination of the particle trajectory before and after the target. The experiments have been conducted at the Marburg Ion Beam Therapy Center with carbon ion beams and the measurement concept was validated by comparison with radiochromic films. This work shows that the new method is very efficient and precise to measure the perturbations due to fiducial markers with a tracker system. Three dimensional fluence distributions of all particle trajectories were reconstructed and the maximum cold spots due to the markers and their position along the beam axis were quantified. In this study, four small commercial markers with different geometries and materials (gold and carbon-coated ZrO2) were evaluated. The gold markers showed stronger perturbations than the lower density ones. However, it is important to consider that low density and low atomic number fiducial markers are not always visible on x-ray projections.


Sujet(s)
Marques de positionnement , Radiothérapie par ions lourds/normes , Positionnement du patient , Diffusion de rayonnements , Artéfacts , Or , Humains , Planification de radiothérapie assistée par ordinateur
6.
Phys Med Biol ; 64(20): 205012, 2019 10 16.
Article de Anglais | MEDLINE | ID: mdl-31530751

RÉSUMÉ

Measured cross sections for the production of the PET isotopes [Formula: see text], [Formula: see text] and [Formula: see text] from carbon and oxygen targets induced by protons (40-220 [Formula: see text]) and carbon ions (65-430 [Formula: see text]) are presented. These data were obtained via activation measurements of irradiated graphite and beryllium oxide targets using a set of three scintillators coupled by a coincidence logic. The measured cross sections are relevant for the PET particle range verification method where accurate predictions of the [Formula: see text] emitter distribution produced by therapeutic beams in the patient tissue are required. The presented dataset is useful for validation and optimization of the nuclear reaction models within Monte Carlo transport codes. For protons the agreement of a radiation transport calculation using the measured cross sections with a thick target PET measurement is demonstrated.


Sujet(s)
Radio-isotopes du carbone/métabolisme , Radiothérapie par ions lourds , Radio-isotopes de l'oxygène/métabolisme , Fantômes en imagerie , Tomographie par émission de positons/méthodes , Protonthérapie , Humains , Méthode de Monte Carlo , Dosimétrie en radiothérapie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...