Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 147
Filtrer
2.
Article de Anglais | MEDLINE | ID: mdl-38852066

RÉSUMÉ

BACKGROUND: J waves may be augmented by coronary angiography (CAG) or intracoronary drug administration but the underlying mechanism is unknown. PURPOSE: The effect of intracoronary normal saline (NS) on J waves were investigated. PATIENTS AND METHODS: After the standard CAG using iopamidol (IopamiroR Inj), NS was injected into the right coronary artery in 10 patients with and eight patients without J waves at the baseline. The 12-lead ECG was monitored, stored on a computer and retrieved later for measurement of the J wave amplitude before or during the coronary interventions. RESULTS: J waves in leads II, III and aVF at baseline increased significantly in each lead during the right CAG and NS injection into the right coronary artery. The J wave changes were similar between the two interventions and distinct similar alterations were observed in the QRS complex. We postulated that the ischemic myocardium that was induced during CAG or intracoronary NS administration slowed the conduction velocity of depolarization in the perfusion territory and delayed the timing of J waves to appear. Then, the delayed appearance of J waves would be less opposed by electromotive force from other areas resulting in augmentation. CONCLUSION: J wave augmentation was observed during CAG and intracoronary NS administration. As a mechanism of augmentation, we postulated that contrast media and NS induce myocardial ischemia and delay the timing of J waves to a point of less opposition by electromotive force from other areas. HIGHLIGHTS: J wave augmentation has been reported during intracoronary injection of contrast media or drugs. The present study confirmed that normal saline alone was able to augment J waves. Mechanistically, coronary interventions using anoxic solutions can cause regional myocardial ischemia and reduce the conduction velocity of depolarization. Then, delayed J waves are less opposed by the electromotive force from remote areas which leads to augmentation. When a drug is diluted in normal saline and given intracoronarily, changes in J waves can be due to normal saline. The pathophysiological and clinical significance of J waves augmented during coronary interventions need to be established.

3.
Pancreatology ; 24(5): 740-746, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38926041

RÉSUMÉ

OBJECTIVES: Pancreatic ductal adenocarcinoma (PDAC) with a diameter ≤10 mm and high-grade pancreatic intraepithelial neoplasia (HG-PanIN) require pre-operative diagnosis. Most cases present only indirect imaging findings without visible tumors on endoscopic ultrasound (EUS). Therefore, EUS-guided fine-needle aspiration/biopsy is not applicable. An alternative diagnostic method is pancreatic juice cytology (PJC) via endoscopic naso-pancreatic drainage (ENPD-PJC), which is not the standard practice. This study aimed to investigate ENPD-PJC for diagnosing suspected PDAC/HG-PanIN cases without visible tumors on EUS. METHODS: Data of patients with suspected PDAC/HG-PanIN without visible tumors who underwent PJC were retrospectively evaluated. One PJC sample was collected during endoscopic retrograde pancreatography (ERP-PJC), and 12 samples were collected during ENPD-PJC, 3-hourly for cytological analysis. ERP-PJC, ERP/ENPD-PJC, and ENPD-PJC positivity indicated cytologically positive samples. Patients with positive/negative PJC with follow-up for <4-years were excluded as undiagnosed cases. A non-malignant diagnosis was based on histopathological absence/stable imaging findings for ≥4-years. The primary endpoint was to demonstrate that ERP/ENPD-PJC has a higher diagnostic ability than ERP-PJC. RESULTS: Twenty-two patients with histopathologically diagnosed PDAC/HG-PanIN and 31 with a non-malignant diagnosis were enrolled. ERP-PJC, ERP/ENPD-PJC, and ENPD-PJC showed sensitivities of 36.4 %, 86.4 %, and 77.3 %, specificities of 93.5 %, 87.1 %, and 93.5 %, and accuracies of 69.8 %, 86.7 %, and 86.7 %, respectively. ERP/ENPD-PJC and ENPD-PJC demonstrated superior sensitivity and accuracy compared to ERP-PJC. A greater occurrence of positive outcomes markedly distinguished true positives from false positives. CONCLUSIONS: ERP/ENPD-PJC and ENPD-PJC had higher diagnostic accuracies for PDAC/HG-PanIN without visible tumors on EUS. ENPD-PJC is recommended for the diagnosis of these lesions.


Sujet(s)
Carcinome du canal pancréatique , Endosonographie , Suc pancréatique , Tumeurs du pancréas , Humains , Tumeurs du pancréas/anatomopathologie , Tumeurs du pancréas/imagerie diagnostique , Tumeurs du pancréas/diagnostic , Mâle , Femelle , Sujet âgé , Adulte d'âge moyen , Suc pancréatique/cytologie , Études rétrospectives , Carcinome du canal pancréatique/imagerie diagnostique , Carcinome du canal pancréatique/anatomopathologie , Endosonographie/méthodes , Sujet âgé de 80 ans ou plus , Adulte , Épithélioma in situ/anatomopathologie , Épithélioma in situ/imagerie diagnostique , Sensibilité et spécificité , Cytologie
4.
Catheter Cardiovasc Interv ; 103(6): 833-842, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38639137

RÉSUMÉ

BACKGROUND: Stent underexpansion, typically related to lesion calcification, is the strongest predictor of adverse events after percutaneous coronary intervention (PCI). Although uncommon, underexpansion may also occur in non-severely calcified lesions. AIM: We sought to identify the prevalence and anatomical characteristics of underexpansion in non-severely calcified lesions. METHODS: We included 993 patients who underwent optical coherence tomography-guided PCI of 1051 de novo lesions with maximum calcium arc <180°. Negative remodeling (NR) was the smallest lesion site external elastic lamina diameter that was also smaller than the distal reference. Stent expansion was evaluated using a linear regression model accounting for vessel tapering; underexpansion required both stent expansion <70% and stent area <4.5mm2. RESULTS: Underexpansion was observed in 3.6% of non-heavily calcified lesions (38/1051). Pre-stent maximum calcium arc and thickness were greater in lesions with versus without underexpansion (median 119° vs. 85°, p = 0.002; median 0.95 mm vs. 0.78 mm, p = 0.008). NR was also more common in lesions with underexpansion (44.7% vs. 24.5%, p = 0.007). In the multivariable logistic regression model, larger and thicker eccentric calcium, mid left anterior descending artery (LAD) location, and NR were associated with underexpansion in non-severely calcified lesions. The rate of underexpansion was especially high (30.7%) in lesions exhibiting all three morphologies. Two-year TLF tended to be higher in underexpanded versus non-underexpanded stents (9.7% vs. 3.7%, unadjusted hazard ratio [95% confidence interval] = 3.02 [0.92, 9.58], p = 0.06). CONCLUSION: Although underexpansion in the absence of severe calcium (<180°) is uncommon, mid-LAD lesions with NR and large and thick eccentric calcium were associated with underexpansion.


Sujet(s)
Maladie des artères coronaires , Vaisseaux coronaires , Intervention coronarienne percutanée , Endoprothèses , Tomographie par cohérence optique , Calcification vasculaire , Humains , Mâle , Femelle , Calcification vasculaire/imagerie diagnostique , Calcification vasculaire/thérapie , Intervention coronarienne percutanée/instrumentation , Intervention coronarienne percutanée/effets indésirables , Sujet âgé , Adulte d'âge moyen , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie , Prévalence , Facteurs de risque , Vaisseaux coronaires/imagerie diagnostique , Résultat thérapeutique , Études rétrospectives , Indice de gravité de la maladie , Conception de prothèse , Valeur prédictive des tests , Facteurs temps , Coronarographie , Remodelage vasculaire
5.
Cardiovasc Interv Ther ; 39(3): 241-251, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38642290

RÉSUMÉ

Despite guideline-based recommendation of the interchangeable use of instantaneous wave-free ratio (iFR) and fractional flow reserve (FFR) to guide revascularization decision-making, iFR/FFR could demonstrate different physiological or clinical outcomes in some specific patient or lesion subsets. Therefore, we sought to investigate the impact of difference between iFR and FFR-guided revascularization decision-making on clinical outcomes in patients with left main disease (LMD). In this international multicenter registry of LMD with physiological interrogation, we identified 275 patients in whom physiological assessment was performed with both iFR/FFR. Major adverse cardiovascular event (MACE) was defined as a composite of death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The receiver-operating characteristic analysis was performed for both iFR/FFR to predict MACE in respective patients in whom revascularization was deferred and performed. In 153 patients of revascularization deferral, MACE occurred in 17.0% patients. The optimal cut-off values of iFR and FFR to predict MACE were 0.88 (specificity:0.74; sensitivity:0.65) and 0.76 (specificity:0.81; sensitivity:0.46), respectively. The area under the curve (AUC) was significantly higher for iFR than FFR (0.74; 95%CI 0.62-0.85 vs. 0.62; 95%CI 0.48-0.75; p = 0.012). In 122 patients of coronary revascularization, MACE occurred in 13.1% patients. The optimal cut-off values of iFR and FFR were 0.92 (specificity:0.93; sensitivity:0.25) and 0.81 (specificity:0.047; sensitivity:1.00), respectively. The AUCs were not significantly different between iFR and FFR (0.57; 95%CI 0.40-0.73 vs. 0.46; 95%CI 0.31-0.61; p = 0.43). While neither baseline iFR nor FFR was predictive of MACE in patients in whom revascularization was performed, iFR-guided deferral seemed to be safer than FFR-guided deferral.


Sujet(s)
Maladie des artères coronaires , Fraction du flux de réserve coronaire , Humains , Fraction du flux de réserve coronaire/physiologie , Mâle , Femelle , Sujet âgé , Maladie des artères coronaires/physiopathologie , Maladie des artères coronaires/chirurgie , Maladie des artères coronaires/diagnostic , Adulte d'âge moyen , Coronarographie , Enregistrements , Revascularisation myocardique/méthodes , Courbe ROC , Cathétérisme cardiaque/méthodes , Études rétrospectives
6.
JACC Cardiovasc Interv ; 17(4): 491-501, 2024 Feb 26.
Article de Anglais | MEDLINE | ID: mdl-38340105

RÉSUMÉ

BACKGROUND: Intravascular ultrasound (IVUS) studies show that one-quarter of left anterior descending (LAD) arteries have a myocardial bridge. An MB may be associated with stent failure when the stent extends into the MB. OBJECTIVES: The aim of this study was to investigate: 1) the association between an MB and chronic total occlusion (CTO) in any LAD lesions; and 2) the association between an MB and subsequent clinical outcomes after percutaneous coronary intervention in LAD CTOs. METHODS: A total of 3,342 LAD lesions with IVUS-guided percutaneous coronary intervention (280 CTO and 3,062 non-CTO lesions) were included. The primary outcome was target lesion failure (cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischemic-driven target lesion revascularization). RESULTS: An MB by IVUS was significantly more prevalent in LAD CTOs than LAD non-CTOs (40.4% [113/280] vs 25.8% [789/3,062]; P < 0.0001). The discrepancy in CTO length between angiography and IVUS was greater in 113 LAD CTOs with an MB than 167 LAD CTOs without an MB (6.0 [Q1, Q3: 0.1, 12.2] mm vs 0.2 [Q1, Q3: -1.4, 8.4] mm; P < 0.0001). Overall, 48.7% (55/113) of LAD CTOs had a stent that extended into an MB after which target lesion failure was significantly higher compared to a stent that did not extend into an MB (26.3% vs 0%; P = 0.0004) or compared to an LAD CTO without an MB (26.3% vs 9.6%; P = 0.02). CONCLUSIONS: An MB was more common in LAD CTO than non-CTO LAD lesions. If present, approximately one-half of LAD CTOs had a stent extending into an MB that, in turn, was associated with worse outcomes.


Sujet(s)
Occlusion coronarienne , Infarctus du myocarde , Intervention coronarienne percutanée , Humains , Occlusion coronarienne/imagerie diagnostique , Occlusion coronarienne/thérapie , Résultat thérapeutique , Intervention coronarienne percutanée/effets indésirables , Coronarographie , Maladie chronique
7.
EuroIntervention ; 20(3): e207-e215, 2024 Feb 05.
Article de Anglais | MEDLINE | ID: mdl-38343369

RÉSUMÉ

BACKGROUND: Outcomes after percutaneous coronary intervention (PCI) for de novo ostial right coronary artery (RCA) lesions are poor. AIMS: We used intravascular ultrasound (IVUS) to clarify the morphological patterns of de novo ostial RCA lesions and their associated clinical outcome. METHODS: Among 5,102 RCA IVUS studies, 170 de novo ostial RCA stenoses (within 3 mm from the aorto-ostium) were identified. These were classified as 1) isolated ostial lesions (no disease extending beyond 10 mm from the ostium and without a calcified nodule [CN]); 2) ostial CN, typically with diffuse disease (disease extending beyond 10 mm); and 3) ostial lesions with diffuse disease but without a CN. The primary outcome was target lesion failure (TLF: cardiac death, target vessel myocardial infarction, definite stent thrombosis, and ischaemia-driven target lesion revascularisation). RESULTS: The prevalence of an isolated ostial lesion was 11.8% (n=20), 47.6% (n=81) were ostial CN, and 40.6% (n=69) were ostial lesions with diffuse disease. Compared to ostial lesions with diffuse disease, isolated lesions were more common in women (75.0% vs 42.0%; p=0.01), and CN were associated with older age (median [first, third quartile] 76 [70, 83] vs 69 [63, 81] years old; p=0.002). The Kaplan-Meier rate of TLF at 2 years was significantly higher in patients with CN (21.6%) compared to diffuse lesions (8.2%) (p=0.04), and patients with isolated lesions had no events. A multivariable Cox proportional hazard model revealed that CN were significantly associated with TLF (hazard ratio 6.63, 95% confidence interval: 1.28-34.3; p=0.02). CONCLUSIONS: Ostial RCA lesions have specific morphologies - detectable by IVUS - that may be associated with long-term clinical outcomes.


Sujet(s)
Maladie des artères coronaires , Endoprothèses à élution de substances , Intervention coronarienne percutanée , Humains , Femelle , Sujet âgé de 80 ans ou plus , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie , Maladie des artères coronaires/étiologie , Intervention coronarienne percutanée/effets indésirables , Résultat thérapeutique , Facteurs de risque , Coronarographie
8.
ACS Nano ; 2024 Feb 05.
Article de Anglais | MEDLINE | ID: mdl-38316049

RÉSUMÉ

Lead halide perovskite nanocrystals (NCs) have attracted much attention as light-source materials for light-emitting diodes, lasers, and quantum light emitters. The luminescence properties of perovskite NCs and the performance of NC-based light-source devices depend on trion and biexciton dynamics. Here, we examined the size dependence of trion and biexciton binding energies by conducting low-temperature single-dot spectroscopy on three different perovskite NCs: CsPbBr3, CsPbI3, and FAPbBr3. While the photoluminescence spectral widths of the all-inorganic CsPbBr3 and CsPbI3 NCs were narrow, compared with those of the organic-inorganic hybrid FAPbBr3 NCs, the binding energies of trions and biexcitons of all three samples showed similar size dependences, independent of the A-site cation and halogen. The effective-mass approximation calculations implied the importance of dynamical dielectric screening on the formation of trions and biexcitons.

9.
J Clin Med ; 12(22)2023 Nov 10.
Article de Anglais | MEDLINE | ID: mdl-38002649

RÉSUMÉ

Endoscopic transpapillary gallbladder drainage (ETGBD) is recommended for patients with acute cholecystitis at high risk for surgery/percutaneous transhepatic gallbladder drainage (PTGBD). Endoscopic ultrasound-guided gallbladder drainage (EUS-GBD) has higher success and mortality rates than ETGBD. Optimal endoscopic drainage remains controversial. Patients with moderate/severe acute cholecystitis and high risk for surgery/PTGBD who underwent ETGBD were enrolled. In the new-ETGBD (N-ETGBD)/traditional-ETGBD (T-ETGBD) strategy, patients in whom the initial ETGBD failed underwent rescue-EUS-GBD in the same endoscopic session/rescue-PTGBD, respectively. Therapeutic outcomes were compared. Patients who could not undergo rescue-EUS-GBD/PTGBD owing to poor general conditions received conservative treatment. Technical success was defined as successful ETGBD or successful rescue-EUS-GBD/PTGBD. Forty-one/forty patients were enrolled in the N-ETGBD/T-ETGBD groups, respectively. The N-ETGBD group had a higher, though non-significant, technical success rate compared to the T-ETGBD group (97.6 vs. 90.0%, p = 0.157). The endoscopic technical success rate was significantly higher in the N-ETGBD than in the T-ETGBD group (97.6 vs. 82.5%, p = 0.023). The clinical success/adverse event rates were similar between both groups. The hospitalization duration was significantly shorter in the N-ETGBD than in the T-ETGBD group (6.6 ± 3.9 vs. 10.1 ± 6.4 days, p < 0.001). ETGBD with EUS-GBD as a rescue backup may be an ideal hybrid drainage for emergency endoscopic gallbladder drainage in high-risk surgical patients.

10.
J Clin Med ; 12(19)2023 Oct 02.
Article de Anglais | MEDLINE | ID: mdl-37834976

RÉSUMÉ

In the present prospective case series study, we investigated the lesion-detection ability of an AI-equipped colonoscopy as an addition to colonoscopy (CS) screening. Participants were 100 patients aged ≥20 years who had not undergone CS at the study site in the last 3 years and passed the exclusion criteria. CS procedures were conducted using conventional white light imaging and computer-aided detection (CADe). Adenoma detection rate (ADR; number of individuals with at least one adenoma detected) was compared between the conventional group and the CADe group. Of the 170 lesions identified, the ADR of the CADe group was significantly higher than the ADR of the conventional group (69% vs. 61%, p = 0.008). For the expert endoscopists, although ADR did not differ significantly, the mean number of detected adenomas per procedure (MAP) was significantly higher in the CADe group than in the conventional group (1.7 vs. 1.45, p = 0.034). For non-expert endoscopists, ADR and MAP were significantly higher in the CADe group than in the conventional group (ADR 69.5% vs. 56.6%, p = 0.016; MAP 1.66 vs. 1.11, p < 0.001). These results indicate that the CADe function in CS screening has a positive effect on adenoma detection, especially for non-experts.

12.
Circ Cardiovasc Interv ; 16(6): e012700, 2023 06.
Article de Anglais | MEDLINE | ID: mdl-37339234

RÉSUMÉ

BACKGROUND: The majority of randomized controlled trials of revascularization decision-making excludes left main coronary artery disease (LMD). Therefore, contemporary clinical outcomes of patients with stable coronary artery disease and LMD with proven ischemia remain poorly understood. The aim of this study was to assess the long-term clinical outcomes of physiologically significant LMD according to the treatment strategies of revascularization versus revascularization deferral. METHODS: In this international multicenter registry of stable LMD interrogated with the instantaneous wave-free ratio, patients with physiologically significant ischemia (instantaneous wave-free ratio ≤0.89) were analyzed according to the coronary revascularization (n=151) versus revascularization deferral (n=74). Propensity score matching was performed to adjust for baseline clinical characteristics. The primary end point was a composite of death, nonfatal myocardial infarction, and ischemia-driven target lesion revascularization of left main stem. The secondary end points were as follows: cardiac death or spontaneous LMD-related myocardial infarction; and ischemia-driven target lesion revascularization of left main stem. RESULTS: At a median follow-up period of 2.8 years, the primary end point occurred in 11 patients (14.9%) in the revascularized group and 21 patients (28.4%) in the deferred group (hazard ratio, 0.42 [95% CI, 0.20-0.89]; P=0.023). For the secondary end points, cardiac death or LMD-related myocardial infarction occurred significantly less frequently in the revascularized group (0.0% versus 8.1%; P=0.004). The rate of ischemia-driven target lesion revascularization of left main stem was also significantly lower in the revascularized group (5.4% versus 17.6%; hazard ratio, 0.20 [95% CI, 0.056-0.70]; P=0.012). CONCLUSIONS: In patients who underwent revascularization for stable coronary artery disease and physiologically significant LMD determined by instantaneous wave-free ratio, the long-term clinical outcomes were significantly improved as compared with those in whom revascularization was deferred.


Sujet(s)
Maladie des artères coronaires , Infarctus du myocarde , Intervention coronarienne percutanée , Humains , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie , Résultat thérapeutique , Infarctus du myocarde/étiologie , Pontage aortocoronarien/effets indésirables , Revascularisation myocardique/effets indésirables , Mort , Intervention coronarienne percutanée/effets indésirables
13.
EuroIntervention ; 19(5): e383-e393, 2023 Aug 07.
Article de Anglais | MEDLINE | ID: mdl-37283548

RÉSUMÉ

BACKGROUND: Despite a high rate of in-stent restenosis (ISR) after stenting the right coronary artery (RCA) ostium, the mechanism of ostial RCA ISR is not well understood. AIMS: We aimed to clarify the cause of ostial RCA ISR using intravascular ultrasound (IVUS). METHODS: Overall, 139 ostial RCA ISR lesions were identified with IVUS, pre-revascularisation. Primary ISR mechanisms were classified as follows: 1) neointimal hyperplasia (NIH); 2) neoatherosclerosis; 3) ostium not covered by the stent; 4) stent fracture or deformation; 5) stent underexpansion (old minimum stent area <4.0 mm2 or stent expansion <50%); or 6) a protruding calcified nodule. RESULTS: The median duration from prior stenting was 1.2 (first quartile 0.6, third quartile 3.1) years. The primary mechanisms of ISR were NIH in 25% (n=35) of lesions, neoatherosclerosis in 22% (n=30), uncovered ostium in 6% (n=9) (biological cause 53%, n=74), stent fracture or deformation in 25% (n=35), underexpansion in 11% (n=15), and protruding calcified nodules in 11% (n=15) (mechanical cause 47%, n=65). Including secondary mechanisms, 51% (n=71) of ostial RCA ISRs had stent fractures that were associated with greater hinge motion of the ostial-aorta angle during the cardiac cycle. The Kaplan-Meier rate of target lesion failure at 1 year was 11.5%. When the mechanically caused ISRs were treated without new stents, they suffered a higher subsequent event rate (41.4%) compared with non-mechanical causes or mechanical causes treated without restenting (7.8%, unadjusted hazard ratio 6.44, 95% confidence interval: 2.33-17.78; p<0.0001). CONCLUSIONS: Half of the ostial RCA ISRs were due to mechanical causes. Subsequent event rates were high, especially in mechanically caused ISRs treated without the implantation of a new stent.


Sujet(s)
Resténose coronaire , Humains , Resténose coronaire/imagerie diagnostique , Resténose coronaire/étiologie , Resténose coronaire/thérapie , Vaisseaux coronaires/imagerie diagnostique , Vaisseaux coronaires/chirurgie , Coronarographie/effets indésirables , Résultat thérapeutique , Endoprothèses/effets indésirables
14.
JACC Cardiovasc Interv ; 16(9): 1024-1035, 2023 05 08.
Article de Anglais | MEDLINE | ID: mdl-37164599

RÉSUMÉ

BACKGROUND: Whether an eruptive or noneruptive target lesion calcified nodule (CN) portends worse acute and long-term clinical outcomes after stenting has not been established. OBJECTIVES: The authors sought to compare acute and long-term clinical outcomes in eruptive CN vs noneruptive CN morphology. METHODS: Using optical coherence tomography, an eruptive CN was defined as an accumulation of small calcium fragments protruding and disrupting the overlying fibrous cap, typically with small amount of thrombus. A noneruptive CN was defined as an accumulation of small calcium fragments with a smooth intact fibrous cap without an overlying thrombus. The primary endpoint was target lesion failure (TLF) including cardiac death, target vessel myocardial infarction, or clinically driven target lesion revascularization in patients with ≥6-month follow-up. RESULTS: Among 3,231 patients with evaluable pre- and postintervention OCT, 236 patients had lesions with CNs (7.3%). After eliminating 4 secondary lesions and 6 patients without ≥6-month follow-up, 126 (54.8%) lesions with eruptive CNs and 104 (45.2%) lesions with noneruptive CNs formed the current report. Compared with noneruptive CNs, eruptive CNs were independently associated with greater stent expansion (89.2% ± 18.7% vs. 81.5% ± 18.9%; P = 0.003) after adjusting for morphologic and procedural factors. At 2 years, eruptive CNs trended toward more TLF compared with noneruptive CNs (Kaplan-Meier estimates, 19.8% vs 12.5%; P = 0.11) and significantly more target lesion revascularization (18.3% vs 9.6%; P = 0.04). In the adjusted model, eruptive CNs were independently associated with 2-year TLF (HR: 2.07; 95% CI: 1.01-4.50; P = 0.048). CONCLUSIONS: Compared with noneruptive CN morphology, lesions with an eruptive CN appearance on optical coherence tomography had a worse poststent long-term clinical outcome despite better acute stent expansion.


Sujet(s)
Maladie des artères coronaires , Exanthème , Intervention coronarienne percutanée , Thrombose , Humains , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie , Calcium , Résultat thérapeutique , Intervention coronarienne percutanée/effets indésirables , Endoprothèses , Fibrose
15.
Cardiovasc Interv Ther ; 38(3): 287-298, 2023 Jul.
Article de Anglais | MEDLINE | ID: mdl-37017899

RÉSUMÉ

There have been no studies comparing clinical outcomes of physiology-guided revascularization in patients with unprotected left main coronary disease (ULMD) between percutaneous coronary intervention (PCI) vs. coronary artery bypass grafting (CABG). The aim of this study was to assess the long-term clinical outcomes between PCI and CABG of patients with physiologically significant ULMD. From an international multicenter registry of ULMD patients interrogated with instantaneous wave-free ratio (iFR), we analyzed data from 151 patients (85 PCI vs. 66 CABG) who underwent revascularization according to the cutoff value of iFR ≤ 0.89. Propensity score matching was employed to adjust for baseline clinical characteristics. The primary endpoint was a composite of all-cause death, non-fatal myocardial infarction, and ischemia-driven target lesion revascularization. The secondary endpoints were the individual components of the primary endpoint. Mean age was 66.6 (± 9.2) years, 79.2% male. Mean SYNTAX score was 22.6 (± 8.4) and median iFR was 0.83 (IQR 0.74-0.87). After performing propensity score matching analysis, 48 patients treated with CABG were matched to those who underwent PCI. At a median follow-up period of 2.8 years, the primary endpoint occurred in 8.3% in PCI group and 20.8% in CABG group, respectively (HR 3.80; 95% CI 1.04-13.9; p = 0.043). There was no difference in each component of the primary event (p > 0.05 for all). Within the present study, iFR-guided PCI was associated with lower cardiovascular events rate in patients with ULMD and intermediate SYNTAX score, as compared to CABG. State-of-the-art PCI vs. CABG for ULMD. Study design and primary endpoint in patients with physiologically significant ULMD. MACE was defined as the composite of all-cause death, non-fatal myocardial infarction, and target lesion revascularization. The blue line denotes the PCI arm, and the red line denotes the CABG arm. PCI was associated with significantly lower risk of MACE than CABG. CABG: coronary artery bypass grafting; iFR: instantaneous wave-free ratio; MACE: major adverse cardiovascular events; PCI: percutaneous coronary intervention; ULMD: unprotected left main coronary artery disease.


Sujet(s)
Maladie des artères coronaires , Infarctus du myocarde , Intervention coronarienne percutanée , Humains , Mâle , Sujet âgé , Femelle , Maladie des artères coronaires/diagnostic , Maladie des artères coronaires/chirurgie , Maladie des artères coronaires/complications , Intervention coronarienne percutanée/effets indésirables , Résultat thérapeutique , Pontage aortocoronarien/effets indésirables , Infarctus du myocarde/étiologie , Enregistrements , Facteurs de risque
16.
Catheter Cardiovasc Interv ; 101(6): 1045-1052, 2023 05.
Article de Anglais | MEDLINE | ID: mdl-36934387

RÉSUMÉ

OBJECTIVES: We aimed to evaluate the diagnostic accuracy of quantitative flow ratio (QFR) in left main (LM) coronary stenoses, using Fractional Flow Reserve (FFR) as reference. BACKGROUND: QFR has demonstrated a high accuracy in determining the functional relevance of coronary stenoses in non-LM. However, there is an important paucity of data regarding its diagnostic value in the specific anatomical subset of LM disease. METHODS: This is a retrospective, observational, multicenter, international, and blinded study including patients with LM stenoses. Cases with significant ostial LM disease were excluded. QFR was calculated from conventional angiograms at blinded fashion with respect to FFR. RESULTS: Sixty-seven patients with LM stenoses were analyzed. Overall, LM had intermediate severity, both from angiographic (diameter stenosis [%DS] 43.8 ± 11.1%) and functional perspective (FFR 0.756 ± 0.105). Mean QFR was 0.733 ± 0.159. Correlation between QFR and FFR was moderate (r = 0.590). Positive and negative predictive value, sensitivity and specificity were 85.4%, 64%, 85.4%, and 69.6% respectively. Classification agreement of QFR and FFR in terms of functional stenosis severity was 78.1%. Area under the receiver operating characteristics of QFR using FFR as reference was 0.82 [95% confidence interval [CI], 0.71-0.93], and significantly better than angiographic evaluation including %DS (area under the receiver-operating characteristic curve [AUC] 0.45 [95% CI, 0.32-0.58], p < 0.001) and minimum lumen diameter (AUC 0.60 [95% CI, 0.47-0.74], p < 0.001). CONCLUSIONS: Compared with FFR, QFR has acceptable diagnostic performance in determining the functional relevance of LM stenosis, being better than conventional angiographic assessment. Nonetheless, caution should be taken when applying functional angiography techniques for the assessment of LM stenosis given its particular anatomical characteristics.


Sujet(s)
Maladie des artères coronaires , Sténose coronarienne , Fraction du flux de réserve coronaire , Humains , Sténose pathologique , Coronarographie/méthodes , Vaisseaux coronaires/imagerie diagnostique , Indice de gravité de la maladie , Reproductibilité des résultats , Résultat thérapeutique , Valeur prédictive des tests
17.
J Clin Med ; 12(6)2023 Mar 20.
Article de Anglais | MEDLINE | ID: mdl-36983393

RÉSUMÉ

Endoscopic ultrasound-guided biliary drainage (EUS-BD) has become comparable to endoscopic retrograde cholangiopancreatography and is now considered a first-line intervention for certain biliary obstructions. Although analysis of experience-related factors may help achieve better outcomes and contribute to its wider adoption, no concrete evidence exists regarding the required operator or institutional experience levels. This study aimed to analyze experience-related factors at beginner multicenters. Patients who underwent EUS-BD using self-expandable metal stents and/or dedicated plastic stents during the study period (up to the first 25 cases since introducing the technique) were retrospectively enrolled from seven beginner institutions and operators. Overall, 90 successful (technical success without early adverse events) and 22 failed (technical failure and/or early adverse events) cases were compared. EUS-BD-related procedures conducted at the time of applicable EUS-BD by each institution/operator were evaluated. The number of institution-conducted EUS-BD procedures (≥7) and operator-conducted EUS screenings (≥436), EUS-guided fine-needle aspirations (FNA) (≥93), and EUS-guided drainages (≥13) significantly influenced improved EUS-BD outcomes (p = 0.022, odds ratio [OR], 3.0; p = 0.022, OR, 3.0; p = 0.022, OR, 3.0; and p = 0.028, OR, 2.9, respectively). Our threshold values, which significantly divided successful and failed cases, were assessed using receiver operating characteristic curve analysis and may provide useful approximate indications for successful EUS-BD.

18.
Pediatr Dev Pathol ; 26(2): 133-137, 2023.
Article de Anglais | MEDLINE | ID: mdl-36461892

RÉSUMÉ

Coronary aneurysm secondary to coronary fistula is a rare condition, with no existing report on its pathological examination. We report the case of a patient diagnosed with a right coronary artery fistula with coronary aneurysm during the fetal period. During follow-up after delivery, the aneurysm became larger, even though the shunt size decreased. We were afraid the aneurysm would rupture and therefore, planned elective catheter embolization. At the age of 4 years, the patient underwent surgery, which involved closing the fistula and making the lumen of the aneurysm smaller. However, the surgery was not catheter embolization as planned because segment 3 branched off from the largest aneurysm where we planned to embolize. Pathologically, the structure of the coronary artery differed from that of a healthy one, with thickened intima and media, fewer scattered smooth muscle cells, widely distributed elastic fibers, and mucoid degeneration in the media. The structure of the coronary artery suggested that the vessel wall was weak and that the aneurysm would rupture if not treated. Postoperative coronary angiography showed that segment 2 was obstructed, while the collaterals from the left coronary artery perfused the area. We could have treated the fistula with a catheter as scheduled.


Sujet(s)
Anévrysme coronarien , Fistule , Cardiopathies congénitales , Enfant , Humains , Enfant d'âge préscolaire , Anévrysme coronarien/diagnostic , Anévrysme coronarien/étiologie , Anévrysme coronarien/chirurgie , Circulation pulmonaire , Fistule/complications , Coronarographie , Cardiopathies congénitales/complications
19.
JACC Adv ; 2(7): 100564, 2023 Sep.
Article de Anglais | MEDLINE | ID: mdl-38939499

RÉSUMÉ

Background: Accurate intravascular ultrasound (IVUS) measurements are important in IVUS-guided percutaneous coronary intervention optimization by choosing the appropriate device size and confirming stent expansion. Objectives: The purpose of this study was to assess the accuracy of machine learning (ML) automatic segmentation of coronary artery vessel and lumen dimensions and balloon sizing. Methods: Using expert analysis as the gold standard, ML segmentation of 60 MHz IVUS images was developed using 8,076 IVUS cross-sectional images from 234 patients, which were randomly split into training (83%) and validation (17%) data sets. The performance of ML segmentation was then evaluated using an independent test data set (437 images from 92 patients). The endpoints were the agreement rate between ML vs experts' measurements for appropriate balloon size selection, and lumen and acute stent areas. Appropriate balloon size was determined by rounding down from the mean vessel diameter or rounding up from the mean lumen diameter to the next balloon size. The difference of lumen area ≥0.5 mm2 was considered as clinically significant. Results: ML model segmentation correlated well with experts' segmentation for training data set with a correlation coefficient of 0.992 and 0.993 for lumen and vessel areas, respectively. The agreement rate in lumen and acute stent areas was 85.5% and 97.0%, respectively. The agreement rate for appropriate balloon size selection was 70.6% by vessel diameter only and 92.4% by adding lumen diameter. Conclusions: ML model IVUS segmentation measurements were well-correlated with those of experts and selected an appropriate balloon size in more than 90% of images.

20.
JACC Cardiovasc Interv ; 15(21): 2206-2217, 2022 11 14.
Article de Anglais | MEDLINE | ID: mdl-36357025

RÉSUMÉ

BACKGROUND: Although the presence of severe stenosis in the left main coronary artery (LMCA) is a well-established predictor of mortality, whether this extends to nonobstructive atherosclerosis in the LMCA is unknown. OBJECTIVES: The aim of this study was to evaluate the association between LMCA disease by intravascular ultrasound (IVUS) and long-term mortality. METHODS: Between 2005 and 2013, 3,239 patients with LMCA IVUS imaging without LMCA revascularization (either before angiography or scheduled based on index angiography or IVUS) were included. The primary and secondary endpoints were all-cause and cardiac mortality at a minimum of 5 years obtained from the National Death Index. RESULTS: The IVUS-measured LMCA minimum lumen area (MLA) and plaque burden were 13.1 ± 5.0 mm2 and 41.7% ± 15.6%, respectively. The median follow-up was 8.2 years. The Kaplan-Meier estimated 12-year all-cause and cardiac death rates were 37.5% and 17.0%, respectively. Greater plaque burden (unadjusted HR per 10%: 1.17; 95% CI: 1.12-1.22; P < 0.0001) and smaller IVUS MLA (unadjusted HR per 1 mm2: 0.98; 95% CI: 0.96-0.99; P = 0.0008) were associated with all-cause death. After adjusting for clinical, angiographic, and IVUS factors, plaque burden (adjusted HR per 10%: 1.12; 95% CI: 1.04-1.21; P = 0.003) but not MLA (adjusted HR per 1 mm2: 1.02; 95% CI: 0.99-1.04; P = 0.18) was associated with long-term all-cause death. These findings were also consistent for long-term cardiac mortality. CONCLUSIONS: In the present large-scale study with a 12-year follow-up, increasing LMCA plaque burden was associated with long-term all-cause and cardiac mortality in patients not undergoing LMCA revascularization, even when the lumen area was preserved.


Sujet(s)
Athérosclérose , Maladie des artères coronaires , Plaque d'athérosclérose , Humains , Vaisseaux coronaires/imagerie diagnostique , Coronarographie/méthodes , Échographie interventionnelle/méthodes , Résultat thérapeutique , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE