Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
J Clin Med ; 11(9)2022 May 09.
Article de Anglais | MEDLINE | ID: mdl-35566791

RÉSUMÉ

The valve-in-valve (ViV) technique is an emerging alternative for the treatment of bioprosthetic structural valve deterioration (SVD) in the tricuspid position. We report on the outcomes of patients treated by a transcatheter tricuspid valve-in-valve (TT-ViV) implantation for symptomatic SVD in the tricuspid position during the years 2010-2019 at our center. Three main outcomes were examined during the follow-up period: TT-ViV hemodynamic data per echocardiography, mortality and NYHA functional class. Our cohort consisted of 12 patients with a mean age 65.4 ± 11.9 years, 83.3% male. The mean time from initial valve intervention to TT-ViV was 17.4 ± 8.7 years. The indications for TT-ViV were varied (41.7% for predominant regurgitation, 33.3% for predominant stenosis and 25.0% with a mixed pathology). All patients were treated with a balloon-expandable device. The mean follow-up was 3.4 ± 1.3 years. Tricuspid regurgitation was ≥ moderate in 57.2% of patients prior to the procedure and this decreased to 0% following the procedure. The mean transtricuspid valve gradients mildly decreased from the mean pre-procedural values of 9.0 mmHg to 7.0 mmHg at one month following the procedure (p = 0.36). Mortality at one year was 8.0% (95% CI 0-23). At the baseline, 4 patients (33.3%) were in NYHA functional class III/IV; this was reduced to 2 patients (18.2%) at the one year follow-up and both were in NYHA III. The TT-ViV procedure offered a safe, feasible and less invasive treatment option for patients with SVD in our detailed cohort.

2.
Front Cardiovasc Med ; 9: 883242, 2022.
Article de Anglais | MEDLINE | ID: mdl-35557522

RÉSUMÉ

The Valve-in-Valve (ViV) technique is an emerging alternative for the treatment of bioprosthetic structural valve deterioration (SVD) in the mitral position. We report on intermediate-term outcomes of patients with symptomatic SVD in the mitral position who were treated by transcatheter mitral valve-in-valve (TM-ViV) implantation during the years 2010-2019 in our center. Three main outcomes were examined during the follow-up period: NYHA functional class, TM-ViV hemodynamic data per echocardiography, and mortality. Our cohort consisted of 49 patients (mean age 77.4 ± 10.5 years, 65.3% female). The indications for TM-ViV were mainly for regurgitant pathology (77.6%). All 49 patients were treated with a balloon-expandable device. The procedure was performed via transapical access in 17 cases (34.7%) and transfemoral vein/trans-atrial septal puncture in 32 cases (65.3%). Mean follow-up was 4.4 ± 2.0 years. 98% and 91% of patients were in NYHA I/II at 1 and 5 years, respectively. Mitral regurgitation was ≥moderate in 86.3% of patients prior to the procedure and this decreased to 0% (p < 0.001) following the procedure and was maintained over 2 years follow-up. The mean trans-mitral valve gradients decreased from pre-procedural values of 10.1 ± 5.1 mmHg to 7.0 ± 2.4 mmHg at 1 month following the procedure (p = 0.03). Mortality at 1 year was 16% (95%, CI 5-26) and 35% (95%, CI 18-49) at 5 years. ViV in the mitral position offers an effective and durable treatment option for patients with SVD at high surgical risk.

3.
Eur Heart J Case Rep ; 6(1): ytac001, 2022 Jan.
Article de Anglais | MEDLINE | ID: mdl-35174306

RÉSUMÉ

BACKGROUND: Intravascular leiomyomatosis (IVL) with intracardiac extension is a rare benign tumour seen exclusively in women, characterized by proliferation of uterine smooth muscle cells through the venous circulation into the inferior vena cava (IVC) and the right heart chambers. CASE SUMMARY: A 47 years old women with history of previous hysterectomy due to myomatosis, presented with nausea, anorexia, and bilateral lower limb swelling over the preceding 2 months. An outpatient abdominal ultrasound discovered a mass in the IVC. Echocardiogram and computed tomography demonstrated a large intravascular mass extending from the pelvis to the right heart chambers. The tumour was completely removed in a concomitant open-heart surgery and laparotomy. Post-operative course was uncomplicated. A month later, the patient was feeling well and in good clinical condition. The histological analysis consisted with IVL. DISCUSSION: Intracardiac leiomyomatosis is a rare clinical condition which requires high index of suspicion. Multimodality imaging is usually required to establish the preoperative diagnosis, although the final diagnosis is achieved with tissue investigation. Complete surgical resection of the tumour is curative and associated with good long-term prognosis.

4.
Front Cardiovasc Med ; 8: 713341, 2021.
Article de Anglais | MEDLINE | ID: mdl-34568456

RÉSUMÉ

The Valve-in-Valve (ViV) technique is an established alternative for the treatment of structural bioprosthetic valve deterioration (SVD). Data describing the intermediate term follow up of patients treated with this approach is scarce. We report on our intermediate-term outcomes of patients with SVD in the Aortic position treated with ViV. Included were patients with symptomatic SVD in the aortic position valve who were treated by Valve in valve transcatheter aortic valve implantation (ViV-TAVI) during the years 2010-2019 in our center. Three main outcomes were examined during the follow up period: NYHA functional class, ViV-TAVI hemodynamic per echocardiography, and mortality. Our cohort consisted of 85 patients (mean age 78.8 ± 8.9 years). The indications for aortic ViV were: SVD isolated aortic stenosis in 37.6%, SVD isolated aortic regurgitation in 42.2% and combined valve pathology in 20.0%. Self-expandable and balloon-expandable devices were used in 73 (85.9%) and 12 (14.1%), respectively. Average follow up was 3.7 ± 2.4 years. 95 and 91% of patients were in NYHA functional class I/II at 1 and 5 year follow up respectively. At one year, the mean trans-aortic valve pressure was 15 ± 9 mmHg and rates of ≥ moderate aortic regurgitation were 3.7%. Mortality at one year was 8.6% (95% CI 2.3-14.4) and 31% (95% CI 16.5-42.5) at 5 years. ViV in the aortic position offers an effective and durable treatment option for patient with SVD, with low rates of all-cause mortality, excellent hemodynamic and improved functional capacity at intermediate follow up.

5.
Am J Cardiol ; 141: 72-78, 2021 02 15.
Article de Anglais | MEDLINE | ID: mdl-33217350

RÉSUMÉ

Transcatheter aortic-valve implantation (TAVI) is an established treatment option in patients with severe symptomatic aortic stenosis. Intermediate and long-term follow up data of these patients is limited. Data was taken from a large all-comer single center prospective registry (2008 to 2019). The primary end point was all-cause mortality. The secondary endpoints were long-term valve hemodynamic performance; paravalvular leak (PVL) at 5-year follow-up. We also report on temporal trends in this cohort. Our cohort included 998 patients with a mean age of 82.3 ± 7.2 years and 52.2% females. TAVI was performed via the transfemoral, trans-apical, subclavian and other access routes in 93.9%, 3.6%, 2.5%, and 0.6% of patients, respectively. A self-expandable device was used in 69.4% of cases, balloon expandable device in 28.1% and in 2.5% other devices. The cumulative risk for all-cause mortality at 5 years was 43.4% (95% CI 39.1 to 47.7). The immediate and long-term valve gradients were low and maintained. On durability analysis at 5 years, severe structural valve deterioration was present in 1.6% of cases. At 5-year follow-up, PVL was moderate in 3.3% and no patients has severe PVL. On temporal trends analysis, we found that the procedural aspects of TAVI improved over time with lower rates of significant PVL and significantly lower procedural mortality. In conclusion, TAVI patients have a favorable long-term outcome, with excellent valve hemodynamic parameters and good clinical outcomes. Over time and with increasing experience, procedural and patient outcomes have improved.


Sujet(s)
Sténose aortique/chirurgie , Prothèse valvulaire cardiaque , Mortalité , Remplacement valvulaire aortique par cathéter/méthodes , Sujet âgé , Sujet âgé de 80 ans ou plus , Maladie de la valve aortique/épidémiologie , Cause de décès , Femelle , Hémodynamique , Humains , Études longitudinales , Mâle , Complications postopératoires/épidémiologie , Défaillance de prothèse , Enregistrements
7.
Can J Cardiol ; 28(6): 728-36, 2012.
Article de Anglais | MEDLINE | ID: mdl-22445099

RÉSUMÉ

BACKGROUND: Endothelial progenitor cells (EPCs) are attenuated, both in number and functionality, in animal models of chronic cardiovascular and metabolic disorders. This effect has subsequently been linked to the aggravation of long-term morbidity and mortality associated with such disorders. The objective was to examine EPC number and survival in chronic diabetic vs nondiabetic patients in conjunction with the examination of their redox, inflammatory, and antioxidant defense system (Nrf2 genes) status in serum and visceral fat. METHODS: Visceral adipose tissue from diabetic and nondiabetic patients undergoing coronary artery bypass graft surgery was analyzed for Nrf2-dependent genes. Oxidative stress was evaluated using thiobarbituric acid-reactive substance assay (TBARS). Peripheral blood, collected 1 day prior to surgery, was evaluated for inflammatory cytokines and EPCs. RESULTS: When compared with controls (P < 0.05), results of the thiobarbituric acid-reactive substance assay were higher in diabetic patients. Although Nrf2-dependent antioxidant proteins (thioredoxin-1 [Trx-1], nicotinamide adenine dinucleotide phosphate [NAD(P)H] quinone oxidoreductase [NQO1], glutathione S-transferase [GST]) were upregulated, heme oxygenase (HO-1) and adiponectin protein expression were lower in the diabetic group (P < 0.05). Serum levels of bilirubin were lower (P < 0.005) while the levels of inflammatory cytokines were higher in diabetic patients (P < 0.05). EPC levels and their colony forming units were significantly lower (P < 0.05) with reduced viability in diabetic patients as compared with nondiabetic patients. CONCLUSIONS: These results demonstrate for the first time that in diabetic patients, there is an inadequate heme oxygenase-adiponectin axis response, which could compromise the compensatory antioxidant and anti-inflammatory effects consequently contributing toward EPC dysfunction in these patients.


Sujet(s)
Glycémie/métabolisme , Diabète de type 2/génétique , Cellules endothéliales/métabolisme , Régulation de l'expression des gènes , Facteur-2 apparenté à NF-E2/génétique , ARN messager/génétique , Cellules souches/physiologie , Adiponectine/métabolisme , Tissu adipeux/métabolisme , Tissu adipeux/anatomopathologie , Technique de Western , Cellules cultivées , Diabète de type 2/métabolisme , Diabète de type 2/anatomopathologie , Cellules endothéliales/anatomopathologie , Femelle , Cytométrie en flux , Heme oxygenase (decyclizing)/métabolisme , Humains , Mâle , Adulte d'âge moyen , NADPH dehydrogenase (quinone)/génétique , NADPH dehydrogenase (quinone)/métabolisme , Facteur-2 apparenté à NF-E2/biosynthèse , Stress oxydatif , Réaction de polymérisation en chaine en temps réel , Substances réactives à l'acide thiobarbiturique/métabolisme
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...