Circulation ; 2024 Jul 08.
Article de Anglais | MEDLINE | ID: mdl-38973458

RÉSUMÉ

BACKGROUND: A dual-chamber leadless pacemaker system has been designed for AV synchronous pacing using wireless, beat-to-beat, implant-to-implant (i2i) communication between distinct atrial and ventricular leadless pacemakers. The AV synchrony achieved across various ambulatory scenarios has yet to be systematically evaluated. METHODS: A prospective, single-arm, unblinded, multicenter, international clinical trial of the leadless pacemaker system was conducted in patients with a conventional dual-chamber pacing indication enrolled from February 2022 to March 2023. Leadless pacemaker systems were implanted, and 12-lead Holter electrocardiographic recordings were collected 3 months after implantation over various postures/activities: sitting, supine, left lateral recumbent, right lateral recumbent, standing, normal walk, and fast walk. An independent Holter core laboratory performed a manual adjudication of the percent of AV synchronous beats using the standard 300-millisecond PR interval limit. Atrium-to-ventricle and ventricle-to-atrium i2i communication success rates were also assessed. Post hoc summary statistics describing the relationships between AV synchrony and i2i success, posture/activity, implantation indication, AV event, and heart rate were calculated. RESULTS: In the evaluable population (n=384 of 464 enrolled [83%]; 61% male; age, 70 years; weight, 82 kg; 60% ejection fraction; 95% of beats evaluable), the mean AV synchrony of 98% of beats observed across all postures using the standard 300-millisecond limit was greater than both atrium-to-ventricle i2i (94%) and ventricle-to-atrium i2i (94%; P<0.001), exceeding both i2i values in 95% of patients. AV synchrony was achieved in >95% of evaluable beats across all postures/activities, implantation indications, AV paced/sensed event combinations, and heart rate ranges (including >100 bpm). CONCLUSIONS: This dual-chamber leadless pacemaker system demonstrated AV synchrony in 98% of evaluable beats at 3 months after implantation. AV synchrony was maintained across postures/activities and remained robust for heart rates >100 bpm.

2.
Cardiovasc Diabetol ; 23(1): 224, 2024 Jun 28.
Article de Anglais | MEDLINE | ID: mdl-38943159

RÉSUMÉ

BACKGROUND: Sodium-glucose cotransporter 2 (SGLT2) inhibitors reduce the risk of hospitalization for heart failure and cardiovascular death with type 2 diabetes; however, their effect on arrhythmias is unclear. The purpose of this study was to investigate the effects of empagliflozin on ventricular arrhythmias in patients with type 2 diabetes. METHODS: A total of 150 patients with type 2 diabetes who were treated with an implantable cardioverter-defibrillator or cardiac resynchronization therapy defibrillator (ICD/CRT-D) were randomized to once-daily empagliflozin or placebo for 24 weeks. The primary endpoint was the change in the number of ventricular arrhythmias from the 24 weeks before to the 24 weeks during treatment. Secondary endpoints included the change in the number of appropriate device discharges and other values. RESULTS: In the empagliflozin group, the number of ventricular arrhythmias recorded by ICD/CRT-D decreased by 1.69 during treatment compared to before treatment, while in the placebo group, the number increased by 1.79. The coefficient for the between-group difference was - 1.07 (95% confidence interval [CI] - 1.29 to - 0.86; P < 0.001). The change in the number of appropriate device discharges during and before treatment was 0.06 in the empagliflozin group and 0.27 in the placebo group, with no significant difference between the groups (P = 0.204). Empagliflozin was associated with an increase in blood ketones and hematocrit and a decrease in blood brain natriuretic peptide and body weight. CONCLUSIONS: In patients with type 2 diabetes treated with ICD/CRT-D, empagliflozin reduces the number of ventricular arrhythmias compared with placebo. Trial registration jRCTs031180120.


Sujet(s)
Composés benzhydryliques , Défibrillateurs implantables , Diabète de type 2 , Défibrillation , Glucosides , Inhibiteurs du cotransporteur sodium-glucose de type 2 , Humains , Diabète de type 2/diagnostic , Diabète de type 2/complications , Diabète de type 2/sang , Diabète de type 2/traitement médicamenteux , Glucosides/usage thérapeutique , Glucosides/effets indésirables , Composés benzhydryliques/usage thérapeutique , Composés benzhydryliques/effets indésirables , Mâle , Inhibiteurs du cotransporteur sodium-glucose de type 2/usage thérapeutique , Inhibiteurs du cotransporteur sodium-glucose de type 2/effets indésirables , Femelle , Sujet âgé , Adulte d'âge moyen , Résultat thérapeutique , Facteurs temps , Défibrillation/instrumentation , Défibrillation/effets indésirables , Méthode en double aveugle , Japon , Thérapie de resynchronisation cardiaque/effets indésirables , Glycémie/métabolisme , Glycémie/effets des médicaments et des substances chimiques
3.
J Arrhythm ; 40(3): 639-642, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38939789

RÉSUMÉ

A 26-year-old man with long QT syndrome (LQTS) underwent subcutaneous implantable cardioverter-defibrillator (S-ICD) implantation. The patient exhibited sinus bradycardia relative to his age. The heart rate decreased, and the QT interval became longer with the administration of ß-blockers, the first-line therapy for LQTS. The patient experienced frequent S-ICD discharges. Subsequently, a single-chamber pacemaker was implanted, and the 12-lead electrocardiogram showed atrial pacing and ventricular sensing at 60 beats per minute with a shorter QTc interval. After converting to "double-device therapy," the patient did not experience any ventricular arrhythmia events.

4.
J Arrhythm ; 40(3): 423-433, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38939793

RÉSUMÉ

Background: Despite the positive impact of implantable cardioverter defibrillators (ICDs) and wearable cardioverter defibrillators (WCDs) on prognosis, their implantation is often withheld especially in Japanese heart failure patients with reduced left ventricular ejection fraction (HFrEF) who have not experienced ventricular tachycardia (VT) or ventricular fibrillation (VF) for uncertain reasons. Recent advancements in heart failure (HF) medications have significantly improved the prognosis for HFrEF. Given this context, a critical reassessment of the treatment and prognosis of ICDs and WCDs is essential, as it has the potential to reshape awareness and treatment strategies for these patients. Methods: We are initiating a prospective multicenter observational study for HFrEF patients eligible for ICD in primary and secondary prevention, and WCD, regardless of device use, including all consenting patients. Study subjects are to be enrolled from 31 participant hospitals located throughout Japan from April 1, 2023, to December 31, 2024, and each will be followed up for 1 year or more. The planned sample size is 651 cases. The primary endpoint is the rate of cardiac implantable electronic device implementation. Other endpoints include the incidence of VT/VF and sudden death, all-cause mortality, and HF hospitalization, other events. We will collect clinical background information plus each patient's symptoms, Clinical Frailty Scale score, laboratory test results, echocardiographic and electrocardiographic parameters, and serial changes will also be secondary endpoints. Results: Not applicable. Conclusion: This study offers invaluable insights into understanding the role of ICD/WCD in Japanese HF patients in the new era of HF medication.

5.
Heart Rhythm ; 2024 Apr 30.
Article de Anglais | MEDLINE | ID: mdl-38697271

RÉSUMÉ

BACKGROUND: The first dual-chamber leadless pacemaker (DC-LP) system consists of 2 separate atrial and ventricular devices that communicate to maintain synchronous atrioventricular pacing and sensing. The initial safety and efficacy were previously reported. OBJECTIVE: The purpose of this study was to evaluate the chronic electrical performance of the DC-LP system. METHODS: Patients meeting standard dual-chamber pacing indications were enrolled and implanted with the DC-LP system (Aveir DR, Abbott), including right atrial and ventricular helix-fixation LPs (atrial leadless pacemaker [ALP], ventricular leadless pacemaker [VLP]). Pacing capture threshold, sensed amplitude, and pacing impedance were collected using the device programmer at prespecified timepoints from 0-6 months postimplant. RESULTS: De novo devices were successfully implanted in 381 patients with complete 6-month data (62% male; age 69 ± 14 years; weight 82 ± 20 kg; 65% sinus nodal dysfunction, 30% atrioventricular block). ALPs were implanted predominantly in the right atrial appendage anterior base and VLPs primarily at the mid-to-apical right ventricular septum. From implant to 1 month, pacing capture thresholds (0.4-ms pulse width) improved in both ALPs (2.4 ± 1.5 V to 0.8 ± 0.8 V; P <.001) and VLPs (0.8 ± 0.6 V to 0.6 ± 0.4 V; P <.001). Sensed amplitudes improved in both ALPs (1.8 ± 1.3 mV to 3.4 ± 1.9 mV; P <.001) and VLPs (8.8 ± 4.0 mV to 11.7 ± 4.2 mV; P <.001). Impedances were stable in ALPs (334 ± 68 Ω to 329 ± 52 Ω; P = .17) and reduced in VLPs (789 ± 351 Ω to 646 ± 190 Ω; P <.001). Electrical measurements remained relatively stable from 1-6 months postimplant. No differences in electrical metrics were observed among ALP or VLP implant locations. CONCLUSION: This first in-human evaluation of the new dual-chamber leadless pacemaker system demonstrated reliable electrical performance throughout the initial 6-month evaluation period.

7.
Heart Rhythm ; 2024 May 07.
Article de Anglais | MEDLINE | ID: mdl-38762820

RÉSUMÉ

BACKGROUND: Implantable cardioverter-defibrillators last longer, and interest in reliable leads with targeted lead placement is growing. The OmniaSecure™ defibrillation lead is a novel small-diameter, catheter-delivered lead designed for targeted placement, based on the established SelectSecure SureScan MRI Model 3830 lumenless pacing lead platform. OBJECTIVE: This trial assessed safety and efficacy of the OmniaSecure defibrillation lead. METHODS: The worldwide LEADR pivotal clinical trial enrolled patients indicated for de novo implantation of a primary or secondary prevention implantable cardioverter-defibrillator/cardiac resynchronization therapy defibrillator, all of whom received the study lead. The primary efficacy end point was successful defibrillation at implantation per protocol. The primary safety end point was freedom from study lead-related major complications at 6 months. The primary efficacy and safety objectives were met if the lower bound of the 2-sided 95% credible interval was >88% and >90%, respectively. RESULTS: In total, 643 patients successfully received the study lead, and 505 patients have completed 12-month follow-up. The lead was placed in the desired right ventricular location in 99.5% of patients. Defibrillation testing at implantation was completed in 119 patients, with success in 97.5%. The Kaplan-Meier estimated freedom from study lead-related major complications was 97.1% at 6 and 12 months. The trial exceeded the primary efficacy and safety objective thresholds. There were zero study lead fractures and electrical performance was stable throughout the mean follow-up of 12.7 ± 4.8 months (mean ± SD). CONCLUSION: The OmniaSecure lead exceeded prespecified primary end point performance goals for safety and efficacy, demonstrating high defibrillation success and a low occurrence of lead-related major complications with zero lead fractures.

8.
J Thorac Dis ; 16(2): 1702-1714, 2024 Feb 29.
Article de Anglais | MEDLINE | ID: mdl-38505041

RÉSUMÉ

Background and Objective: Treatment for atrial fibrillation (AF) has evolved significantly, with pulmonary vein isolation (PVI) becoming an established treatment. However, the outcomes following catheter ablation for persistent AF remain unsatisfactory. Hybrid catheter-surgical ablation has emerged as a therapeutic approach for persistent AF, combining the strengths of both interventions. The purpose of this narrative review is to comprehensively examine the current state of knowledge regarding hybrid ablation for AF. Methods: A thorough PubMed search using the terms "hybrid ablation", "atrial fibrillation", "catheter ablation", and "guideline on cardiology" within the timeframe of 1980 to 2024 resulted in 138,969 articles. Consensus on the selected articles was reached through a series of structured meetings and discussions. Key Content and Findings: PVI has demonstrated higher sinus rhythm maintenance rates, especially for paroxysmal AF. However, the efficacy is not as high for persistent AF. Additional ablation strategies, such as linear ablation, complex fractionated atrial electrogram ablation, low voltage zone ablation as well as posterior wall isolation, lack consistent evidence of effectiveness. Hybrid ablation, involving collaboration between cardiac surgeons and electrophysiologists, presents a promising alternative for hard-to-treat AF. Recent studies report favorable outcomes of hybrid ablation, with atrial arrhythmia-free rates ranging from 53.5% to 76%, surpassing those of catheter ablation alone, which might result from better lesion durability or intervention for non-PV foci and left atrial appendage excision or closure during hybrid ablation. The rate of complications associated with hybrid ablation is higher than catheter ablation alone. Conclusions: While favorable outcomes of hybrid ablation for persistent AF have been reported, it is not recommended for all AF patients due to its invasiveness compared to catheter ablation. Additionally, some patients with persistent AF maintain sinus rhythm with catheter ablation alone. More clinical data are needed to determine which patients are suitable candidates for hybrid ablation.

10.
Pacing Clin Electrophysiol ; 47(1): 127-130, 2024 01.
Article de Anglais | MEDLINE | ID: mdl-38055652

RÉSUMÉ

BACKGROUND: Using third-party resources to manage remote monitoring (RM) data from implantable cardiac electronic devices (CIEDs) can assist in device clinic workflows. However, each hospital-acquired data is not used for further analysis as big data. METHODS AND RESULTS: We developed a real-time and automatically centralized system of CIED information from multiple hospitals. If the extensive data-based analysis suggests individual problems, it can be returned to each hospital. To show its feasibility, we prospectively analyzed data from six hospitals. For example, unexpected abnormal battery levels were easily illustrated without recall information. CONCLUSIONS: The centralized RM system could be a new platform that promotes the utilization of device data as big data, and that information could be used for each patient's practice.


Sujet(s)
Défibrillateurs implantables , Pacemaker , Humains , Technologie de télédétection/méthodes , Troubles du rythme cardiaque/diagnostic , Troubles du rythme cardiaque/thérapie , Monitorage physiologique/méthodes
13.
J Arrhythm ; 39(5): 681-756, 2023 Oct.
Article de Anglais | MEDLINE | ID: mdl-37799799

RÉSUMÉ

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.

14.
Circ J ; 87(12): 1809-1816, 2023 11 24.
Article de Anglais | MEDLINE | ID: mdl-37532552

RÉSUMÉ

BACKGROUND: The Micra leadless pacemaker has demonstrated favorable outcomes in global trials, but its real-world performance and safety in a Japan-specific population is unknown.Methods and Results: Micra Acute Performance (MAP) Japan enrolled 300 patients undergoing Micra VR leadless pacemaker implantation in 15 centers. The primary endpoint was the acute (30-day) major complication rate. The 30-day and 6-month major complication rates were compared to global Micra studies. All patients underwent successful implantation with an average follow-up of 7.23±2.83 months. Compared with previous Micra studies, Japanese patients were older, smaller, more frequently female, and had a higher pericardial effusion risk score. 11 acute major complications were reported in 10 patients for an acute complication rate of 3.33% (95% confidence interval: 1.61-6.04%), which was in line with global Micra trials. Pericardial effusion occurred in 4 patients (1.33%; 3 major, 1 minor). No procedure or device-related deaths occurred. Frailty significantly improved from baseline to follow-up as assessed by Japan Cardiovascular Health Study criteria. CONCLUSIONS: In a Japanese cohort, implantation of the Micra leadless pacemaker had a high success rate and low major complication rate. Despite the Japan cohort being older, smaller, and at higher risk, the safety and performance was in line with global Micra trials.


Sujet(s)
Troubles du rythme cardiaque , Pacemaker , Femelle , Humains , Peuples d'Asie de l'Est , Conception d'appareillage , Pacemaker/effets indésirables , Épanchement péricardique/étiologie , Résultat thérapeutique , Mâle , Troubles du rythme cardiaque/thérapie
15.
J Arrhythm ; 39(3): 454-463, 2023 Jun.
Article de Anglais | MEDLINE | ID: mdl-37324755

RÉSUMÉ

Background: The long-term relationship between fracture-prone implantable cardioverter-defibrillator (ICD) leads and poor prognosis remains unclear in Japanese patients. Methods: We conducted a retrospective review of the records of 445 patients who underwent implantation of advisory/Linox leads (Sprint Fidelis, 118; Riata, nine; Isoline, 10; Linox S/SD, 45) and non-advisory leads (Endotak Reliance, 33; Durata, 199; Sprint non-Fidelis, 31) between January 2005 and June 2012 at our hospital. The primary outcomes were all-cause mortality and ICD lead failure. The secondary outcomes were cardiovascular mortality, heart failure (HF) hospitalization, and the composite outcome of cardiovascular mortality and HF hospitalization. Results: During the follow-up period (median, 8.6 [4.1-12.0] years), there were 152 deaths: 61 (34%) in patients with advisory/Linox leads and 91 (35%) in those with non-advisory leads. There were 32 ICD lead failures: 27 (15%) in patients with advisory/Linox leads and five (2%) in those with non-advisory leads. Multivariate analysis for ICD lead failure demonstrated that the advisory/Linox leads had a 6.65-fold significantly greater risk of ICD lead failure than non-advisory leads. Congenital heart disease (hazard ratio 2.51; 95% confidence interval 1.08-5.83; p = .03) could also independently predict ICD lead failure. Multivariate analysis for all-cause mortality demonstrated no significant association between advisory/Linox leads and all-cause mortality. Conclusions: Patients who have implanted fracture-prone ICD leads should be carefully followed up for ICD lead failure. However, these patients have a long-term survival rate comparable with that of patients with non-advisory ICD leads in Japanese patients.

16.
Circ J ; 87(8): 1058-1067, 2023 07 25.
Article de Anglais | MEDLINE | ID: mdl-37344406

RÉSUMÉ

BACKGROUND: The association between the T-peak to T-end interval (Tp-e) and ventricular arrhythmia (VA) events in cardiac sarcoidosis (CS) is unknown. The purpose of this study was to investigate whether Tp-e was associated with VA events in CS patients with implantable cardioverter defibrillators (ICDs) or cardiac resynchronization therapy defibrillators (CRT-Ds).Methods and Results: We retrospectively studied 50 patients (16 men; mean [±SD] age 56.3±10.5 years) with CS and ICD/CRT-D. The maximum Tp-e in the precordial leads recorded by a 12-lead electrocardiogram after ICD/CRT-D implantation was evaluated. The clinical endpoint was defined as appropriate ICD therapy. During a median follow-up period of 85.0 months, 22 patients underwent appropriate therapy and 10 patients died. Kaplan-Meier analysis revealed that the probability of the clinical endpoint was 28.3% at 2 years and 35.3% at 4 years. The optimal cut-off value of the Tp-e for the prediction of the clinical endpoint was 91 ms, with a sensitivity of 72.7% and a specificity of 87.0% (area under the curve=0.81). Multivariate Cox regression analysis showed that Tp-e ≥91 ms (hazard ratio [HR] 5.10; 95% confidence interval [CI] 1.99-13.1; P<0.001) and a histological diagnosis of CS (HR 3.84; 95% CI 1.28-11.5; P=0.016) were significantly associated with the clinical endpoint. CONCLUSIONS: Tp-e ≥91 ms was a significant predictor of VA events in patients with CS and ICD/CRT-D.


Sujet(s)
Thérapie de resynchronisation cardiaque , Défibrillateurs implantables , Défaillance cardiaque , Sarcoïdose , Mâle , Humains , Adulte d'âge moyen , Sujet âgé , Études rétrospectives , Troubles du rythme cardiaque/thérapie , Thérapie de resynchronisation cardiaque/effets indésirables , Sarcoïdose/thérapie , Résultat thérapeutique , Défaillance cardiaque/thérapie
17.
Heart Rhythm ; 20(9): e17-e91, 2023 09.
Article de Anglais | MEDLINE | ID: mdl-37283271

RÉSUMÉ

Cardiac physiologic pacing (CPP), encompassing cardiac resynchronization therapy (CRT) and conduction system pacing (CSP), has emerged as a pacing therapy strategy that may mitigate or prevent the development of heart failure (HF) in patients with ventricular dyssynchrony or pacing-induced cardiomyopathy. This clinical practice guideline is intended to provide guidance on indications for CRT for HF therapy and CPP in patients with pacemaker indications or HF, patient selection, pre-procedure evaluation and preparation, implant procedure management, follow-up evaluation and optimization of CPP response, and use in pediatric populations. Gaps in knowledge, pointing to new directions for future research, are also identified.


Sujet(s)
Thérapie de resynchronisation cardiaque , Défaillance cardiaque , Enfant , Humains , Faisceau de His , Résultat thérapeutique , Trouble de la conduction cardiaque , Thérapie de resynchronisation cardiaque/méthodes , Défaillance cardiaque/thérapie , Électrocardiographie/méthodes
18.
N Engl J Med ; 388(25): 2360-2370, 2023 Jun 22.
Article de Anglais | MEDLINE | ID: mdl-37212442

RÉSUMÉ

BACKGROUND: Single-chamber ventricular leadless pacemakers do not support atrial pacing or consistent atrioventricular synchrony. A dual-chamber leadless pacemaker system consisting of two devices implanted percutaneously, one in the right atrium and one in the right ventricle, would make leadless pacemaker therapy a treatment option for a wider range of indications. METHODS: We conducted a prospective, multicenter, single-group study to evaluate the safety and performance of a dual-chamber leadless pacemaker system. Patients with a conventional indication for dual-chamber pacing were eligible for participation. The primary safety end point was freedom from complications (i.e., device- or procedure-related serious adverse events) at 90 days. The first primary performance end point was a combination of adequate atrial capture threshold and sensing amplitude at 3 months. The second primary performance end point was at least 70% atrioventricular synchrony at 3 months while the patient was sitting. RESULTS: Among the 300 patients enrolled, 190 (63.3%) had sinus-node dysfunction and 100 (33.3%) had atrioventricular block as the primary pacing indication. The implantation procedure was successful (i.e., two functioning leadless pacemakers were implanted and had established implant-to-implant communication) in 295 patients (98.3%). A total of 35 device- or procedure-related serious adverse events occurred in 29 patients. The primary safety end point was met in 271 patients (90.3%; 95% confidence interval [CI], 87.0 to 93.7), which exceeded the performance goal of 78% (P<0.001). The first primary performance end point was met in 90.2% of the patients (95% CI, 86.8 to 93.6), which exceeded the performance goal of 82.5% (P<0.001). The mean (±SD) atrial capture threshold was 0.82±0.70 V, and the mean P-wave amplitude was 3.58±1.88 mV. Of the 21 patients (7%) with a P-wave amplitude of less than 1.0 mV, none required device revision for inadequate sensing. At least 70% atrioventricular synchrony was achieved in 97.3% of the patients (95% CI, 95.4 to 99.3), which exceeded the performance goal of 83% (P<0.001). CONCLUSIONS: The dual-chamber leadless pacemaker system met the primary safety end point and provided atrial pacing and reliable atrioventricular synchrony for 3 months after implantation. (Funded by Abbott Medical; Aveir DR i2i ClinicalTrials.gov number, NCT05252702.).


Sujet(s)
Troubles du rythme cardiaque , Entraînement électrosystolique , Pacemaker , Humains , Fibrillation auriculaire/thérapie , Fibrillation auriculaire/étiologie , Bloc atrioventriculaire/thérapie , Entraînement électrosystolique/effets indésirables , Entraînement électrosystolique/méthodes , Études de suivi , Pacemaker/effets indésirables , Études prospectives , Résultat thérapeutique , Troubles du rythme cardiaque/thérapie
19.
Circ Arrhythm Electrophysiol ; 16(6): e011714, 2023 06.
Article de Anglais | MEDLINE | ID: mdl-37183700

RÉSUMÉ

BACKGROUND: The role of atrioventricular optimization (AVO) to improve cardiac resynchronization therapy outcomes remains controversial. Previous post hoc analyses of a multicenter trial showed that measures of electrical dyssynchrony (right ventricular-left ventricular [LV] or LV electrical delay durations) are associated with patients who benefit from AVO. METHODS: This was a global, multicenter, prospective, randomized trial of de novo cardiac resynchronization therapy implant patients with an right ventricular-LV duration ≥70 ms to determine whether AVO results in greater reverse remodeling. Patients were randomized 1:1 for either an AVO algorithm (SmartDelay) that determines atrioventricular delay and pacing chamber, biventricular or LV only, or a fixed atrioventricular delay of 120 ms with biventricular pacing. Paired echocardiograms performed at baseline and 6 months were evaluated. The primary end point was echocardiographic cardiac resynchronization therapy response, defined dichotomously as a >15% reduction in LV end-systolic volume. RESULTS: A total of 310 patients (n=120 women) were randomized and had completed 6 months of follow-up. The echocardiographic cardiac resynchronization therapy response rate did not statistically differ between the groups (SmartDelay, 74.8%; fixed, 67.7%; P=0.17). Analyses of prespecified secondary end points demonstrated significant improvements in the absolute (median: SmartDelay, -41.0 mL; fixed, -33.0 mL; P=0.01) and relative change in LV end-systolic volume (SmartDelay, -38.3%; fixed, -27.8%; P=0.03) for patients with SmartDelay optimization. Similar results were observed for the relative improvement in LV ejection fraction (SmartDelay, 46.7%; fixed, 32.1%; P=0.050); absolute improvement in LV ejection fraction trended to be higher with SmartDelay (P=0.06). CONCLUSIONS: Analysis of reverse remodeling parameters demonstrated that AVO via SmartDelay, relative to the nonoptimized fixed atrioventricular delay comparator group, improved absolute and relative changes in LV function in patients with longer right ventricular-LV duration. REGISTRATION: URL: https://www. CLINICALTRIALS: gov; Unique identifier: NCT03089281.


Sujet(s)
Thérapie de resynchronisation cardiaque , Défaillance cardiaque , Humains , Femelle , Thérapie de resynchronisation cardiaque/méthodes , Études prospectives , Résultat thérapeutique , Défaillance cardiaque/diagnostic , Défaillance cardiaque/thérapie , Fonction ventriculaire gauche/physiologie , Remodelage ventriculaire/physiologie
20.
JACC Clin Electrophysiol ; 9(2): 219-228, 2023 02.
Article de Anglais | MEDLINE | ID: mdl-36858688

RÉSUMÉ

BACKGROUND: The difference between the right ventricular (RV) apical stimulus-atrial electrogram (SA) interval during resetting of supraventricular tachycardia (SVT) versus the ventriculoatrial (VA) interval during SVT (ΔSA-VAapex) is an established technique for discerning SVT mechanisms but is limited by a significant diagnostic overlap. OBJECTIVES: This study hypothesized that the difference between the RV SA interval during resetting of SVTs versus the VA interval during SVTs (ΔSA-VA) would yield a more robust differentiation of atrioventricular nodal re-entrant tachycardia (AVNRT) from atrioventricular reciprocating tachycardia (AVRT) when using the RV basal septal stimulation (ΔSA-VAbase) as compared to the RV apical stimulation (ΔSA-VAapex). Moreover, it was predicted that the ΔSA-VAbase might distinguish septal from free wall accessory pathways (APs) effectively. METHODS: In this prospective study, 105 patients with AVNRTs (age 48 ± 20 years, 44% male) and 130 with AVRTs (age 26 ± 18 years, 54% male) underwent programmed ventricular extrastimuli delivered from both the RV basal septum and RV apex. The ΔSA-VA values were compared between the 2 sites. RESULTS: The ΔSA-VAbase was shorter than the ΔSA-VAapex during AVRT (44 ± 30 ms vs 58 ± 29 ms; P < 0.001), and the opposite occurred during AVNRT (133 ± 31 ms vs 125 ± 25 ms; P = 0.03). A ΔSA-VAbase of ≧85 milliseconds had a sensitivity of 97% and specificity of 96% for identifying AVNRT. Furthermore, a ΔSA-VAbase of 45-85 milliseconds identified AVRT with left free wall APs (sensitivity 86%, specificity 95%), 20-45 milliseconds for posterior septal APs (sensitivity 72%, specificity 96%), and <20 milliseconds for right free wall or anterior/mid septal APs (sensitivity 86%, specificity 98%). CONCLUSIONS: The ΔSA-VAbase during programmed ventricular extrastimuli produced a robust differentiation between AVNRT and AVRT regardless of the AP location with ≧85 milliseconds as an excellent cutoff point. This straightforward technique further allowed localizing 4 general AP sites.


Sujet(s)
Tachycardie par réentrée intranodale , Tachycardie supraventriculaire , Septum interventriculaire , Humains , Mâle , Adulte , Adulte d'âge moyen , Sujet âgé , Enfant , Adolescent , Jeune adulte , Femelle , Études prospectives , Ventricules cardiaques