Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Percept Psychophys ; 62(2): 313-20, 2000 Feb.
Article de Anglais | MEDLINE | ID: mdl-10723210

RÉSUMÉ

The purpose of this study was to determine whether temporal pattern and/or spectral complexity were important stimulus parameters for eliciting a cardiac orienting reflex (OR) in low-risk human fetuses. Each of 28 term fetuses was exposed to four sounds formed from the four different combinations of temporal pattern (pulsed, continuous) and spectral complexity (sine wave, /â/). The fetal cardiac electrical signal was captured transabdominally at a rate of 1024 Hz, and fetal R-waves were extracted by using adaptive signal-processing techniques. We found that pulsed sounds elicited a significantly greater decrease in heart rate (HR) than did continuous sounds. However, the HR response was relatively unaffected by spectral complexity. For the pure tone and the phoneme used in this study, our results indicate that temporal characteristics were more effective at eliciting a cardiac OR in human fetuses than was spectral complexity.


Sujet(s)
Éveil/physiologie , Rythme cardiaque foetal/physiologie , Réflexe/physiologie , Perception de la parole/physiologie , Stimulation acoustique , Cardiotocographie , Femelle , Humains , Nouveau-né , Mâle , Phonétique , Grossesse , Traitement du signal assisté par ordinateur , Spectrographie sonore
2.
Pediatr Res ; 44(1): 111-8, 1998 Jul.
Article de Anglais | MEDLINE | ID: mdl-9667380

RÉSUMÉ

Evaluation of nonlinear heart rate (HR) dynamics has received considerable attention in the pediatric literature because such analyses not only provide insight into underlying control mechanisms, but may also help to differentiate between normal and abnormal infants. The purpose of this study was to determine, in eight low risk human fetuses, if nonlinear HR dynamics could be identified by analyzing the dispersion of interbeat intervals at slow (Ds) and fast (Df) HRs. The fetal cardiac electrical signal was captured transabdominally at a resolution of +/- 1 ms. To test the null hypothesis, that the time series is the result of a linear stochastic process, Ds and Df for the original time series were compared with the values calculated for three linear models. The linear models were constructed to preserve the major statistical properties of the original time series, including the mean, SD, and the Fourier power spectrum. For each fetus, there was no evidence of nonlinear cardiac dynamics based on analyses of Ds and Df. In contrast, the distribution of adjacent R-R intervals and the pattern of change across three successive interbeat intervals both revealed significant nonlinearities in HR control in each fetus. If the difference between normal and abnormal infants is the result of aberrant control of nonlinear processes, then our findings indicate that parameters which describe the nonlinearity may be more useful then Ds and Df in assigning a risk status.


Sujet(s)
Rythme cardiaque foetal/physiologie , Score d'Apgar , Électrocardiographie/méthodes , Femelle , Foetus , Âge gestationnel , Humains , Nouveau-né , Loi normale , Grossesse , Valeurs de référence
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE