Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 2 de 2
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Biomed Chromatogr ; 24(10): 1031-7, 2010 Oct.
Article de Anglais | MEDLINE | ID: mdl-20099369

RÉSUMÉ

We describe a simple, rapid and sensitive high-performance liquid chromatography-electrospray ionization tandem mass spectrometric method that was developed for the simultaneous determination of carebastine and pseudoephedrine in human plasma using cisapride as an internal standard. Acquisition was performed in multiple-reaction monitoring mode by monitoring the transitions: m/z 500.43 > 167.09 for carebastine and m/z 166.04 > 147.88 for pseudoephedrine. The devised method involves a simple single-step liquid-liquid extraction with ethyl acetate. Chromatographic separation was performed on a C(18) reversed-phase chromatographic column at 0.2 mL/min by isocratic elution with 10 mM ammonium formate buffer-acetonitrile (30:70, v/v; adjusted to pH 3.3 with formic acid). The devised method was validated over 0.5-100 ng/mL of carebastine and 5-1000 ng/mL of pseudoephedrine with acceptable accuracy and precision, and was successfully applied to a bioequivalence study involving a single oral dose (10 mg of ebastine plus 120 mg of pseudoephedrine complex) to healthy Korean volunteers.


Sujet(s)
Butyrophénones/sang , Chromatographie en phase liquide à haute performance/méthodes , Pipéridines/sang , Pseudoéphédrine/sang , Spectrométrie de masse ESI/méthodes , Butyrophénones/composition chimique , Butyrophénones/pharmacocinétique , Cisapride/analyse , Cisapride/composition chimique , Études croisées , Humains , Concentration en ions d'hydrogène , Mâle , Pipéridines/composition chimique , Pipéridines/pharmacocinétique , Pseudoéphédrine/composition chimique , Pseudoéphédrine/pharmacocinétique , Reproductibilité des résultats , République de Corée , Sensibilité et spécificité , Équivalence thérapeutique , Jeune adulte
2.
J Chromatogr B Analyt Technol Biomed Life Sci ; 877(31): 4059-64, 2009 Dec 01.
Article de Anglais | MEDLINE | ID: mdl-19854118

RÉSUMÉ

A rapid and simple procedure was developed for the determination of cephradine in human plasma using liquid chromatography coupled with electrospray ionization-tandem mass spectrometry (LC-ESI-MS/MS). After trichloroacetic acid (TCA) precipitation of proteins from plasma samples, cephradine and cefaclor (the internal standard; IS) were eluted on a CN column. The isocratic mobile phase used consisted of acetonitrile-water-formic acid (25:75:0.1, v/v/v). Cephradine and the IS were both detected in multiple reaction monitoring (MRM) mode at the transitions: m/z 350.0 --> 90.8 for cephradine and m/z 368.1 --> 106.0 for the IS, respectively. The calibration curve was linear over the concentration range from 0.05 to 50 microg/ml, and correlation coefficients were greater than 0.996. The coefficient of variation of assay precision was less than 9.36%, and its accuracy ranged from 87.92% to 111.16%. The chromatographic run time for each plasma sample was less than 3 min. The developed method was successfully applied to a bioequivalence study of cephradine in healthy male volunteers.


Sujet(s)
Antibactériens/sang , Céfradine/sang , Chromatographie en phase liquide/méthodes , Spectrométrie de masse ESI/méthodes , Spectrométrie de masse en tandem/méthodes , Antibactériens/pharmacocinétique , Calibrage , Céfradine/pharmacocinétique , Humains , Mâle , Normes de référence , Équivalence thérapeutique
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...