Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 8 de 8
Filtrer
1.
J Prosthet Dent ; 125(2): 294-299, 2021 Feb.
Article de Anglais | MEDLINE | ID: mdl-32115221

RÉSUMÉ

STATEMENT OF PROBLEM: Intraoral scanners (IOSs) have some inherent distortions caused by optical and/or software imperfections. However, how other factors such as operator experience, scan time, scanner type, and scan size influence scan accuracy is not clear. PURPOSE: The purpose of this in vitro study was to evaluate the trueness and precision of scans performed by 3 professionals with different levels of experience by using 2 IOSs. MATERIAL AND METHODS: Three operators with low, medium, and high levels of experience scanned a master model 10 times by using 2 IOSs (CEREC Omnicam; Dentsply Sirona and TRIOS 3; 3Shape), resulting in 10 standard tessellation language files for each group (N=60). Each standard tessellation language file was divided into 2 areas (prepared teeth and complete arch). Precision was evaluated by comparing the 10 scans from each examiner for each system. Trueness was evaluated by comparing each scan file with a reference scan obtained from a laboratory scanner (D2000; 3Shape). A 3D analysis software program (Geomagic Control; 3D Systems) was used to perform all the comparisons and superimpositions. The 3-way ANOVA test followed by the Tukey HSD test were used to assess precision and trueness. The 2-way ANOVA followed by the Tukey HSD test was used to assess scan time. The Pearson correlation test was performed between scan time and trueness for both scanners. An additional correlation was performed between scan time and number of images, as well as between number of images and trueness for the TRIOS 3. RESULTS: Statistically significant influences of operator (P<.001), scanner (P<.001), scan size (P<.001), operator and scan size (P<.001), and scanner and scan size (P<.001) were observed. The TRIOS 3 group reported higher precision than the CEREC Omnicam group for complete-arch scans (P<.001), although no difference was observed for scans of the prepared tooth. Medium- (P=.002) and low-experience operators (P<.001) reported lower precision for complete-arch scans performed with CEREC Omnicam when compared with TRIOS 3. The low-experience operator reported significantly worse results for complete-arch scans in comparison with the medium- (P=.008 and P<.001) and high-experience operators (P<.001 and P=.001), by using TRIOS 3 and CEREC Omnicam, respectively. Medium- and high-experience operators reported similar results among themselves. The CEREC Omnicam scanner reported lower trueness for complete-arch scans when compared with the prepared tooth (P<.001); for TRIOS 3, a difference was only observed for the low-experience operator when compared with the high-experience operator (P<.001). The CEREC Omnicam reported lower trueness than the TRIOS 3, except for the medium-experience operator with the prepared tooth scan. Comparing the trueness between operators and considering the same scanner and scan size, all groups were similar. The low-experience operator had a longer scanning time than the medium- and high-experience operators. For TRIOS 3, the low-experience operator obtained the highest number of images during each scan. CONCLUSIONS: The accuracy of intraoral scans was influenced by operator experience, type of IOSs, and scan size. More experienced operators and smaller scan sizes made for more accurate scans. In addition, more experienced operators made faster scans, and the TRIOS 3 was more accurate than the CEREC Omnicam for complete-arch scans.


Sujet(s)
Technique de prise d'empreinte , Modèles dentaires , Conception assistée par ordinateur , Arcade dentaire , Imagerie tridimensionnelle
2.
Braz Oral Res ; 34: e004, 2020.
Article de Anglais | MEDLINE | ID: mdl-32022223

RÉSUMÉ

The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.


Sujet(s)
Céramiques/composition chimique , Conception assistée par ordinateur , Porcelaine dentaire/composition chimique , Verre/composition chimique , Analyse de variance , Collage dentaire/méthodes , Résistance à la flexion , Test de matériaux , Microscopie électronique à balayage , Porosité , Valeurs de référence , Reproductibilité des résultats , Céments résine/composition chimique , Résistance au cisaillement , Propriétés de surface , Diffraction des rayons X
3.
Braz. oral res. (Online) ; 34: e004, 2020. tab, graf
Article de Anglais | LILACS | ID: biblio-1055523

RÉSUMÉ

Abstract The aim of this study was to analyze the structural, morphological and mechanical properties of two different lithium disilicate glass-reinforced ceramics for CAD-CAM systems (IPS e.max CAD and Rosetta SM). Five methodologies were used for both ceramics: microstructure (n = 2) was analyzed using x-ray diffraction (XRD); morphological properties (n = 2) were analyzed by scanning electron microscopy (SEM), with and without hydrofluoric etching; porosity (n = 3) was assessed using 3D micro-computed tomography (micro-CT); flexural strength was measured (n =1 0) using the three-point bending test; and bond strength was determined with self-adhesive resin cement (n = 10), using a microshear bond test. After performing all the tests, the data were analyzed using t-Student test and two-way ANOVA. All the tests used a significance level of α = 0.05. High peak positions corresponding to standard lithium metasilicate and lithium disilicate with similar intensities were observed for both ceramics in the XRD analysis. Morphological analysis showed that the crystalline structure of the two ceramics studied showed no statistical difference after acid etching. Additionally, no significant differences were recorded in the number or size of the pores for the ceramics evaluated. Moreover, no differences in flexural strength were found for the ceramic materials tested, or in the bond strength to ceramic substrates for the resin cements. Based on the study results, no significant differences were found between the two CAD-CAM lithium disilicate glass-reinforced ceramics tested, since they presented similar crystalline structures with comparable intensities, and similar total porosity, flexural strength and bond strength.


Sujet(s)
Céramiques/composition chimique , Conception assistée par ordinateur , Porcelaine dentaire/composition chimique , Verre/composition chimique , Valeurs de référence , Propriétés de surface , Diffraction des rayons X , Test de matériaux , Microscopie électronique à balayage , Reproductibilité des résultats , Analyse de variance , Porosité , Collage dentaire/méthodes , Céments résine/composition chimique , Résistance au cisaillement , Résistance à la flexion
4.
Braz. j. oral sci ; 18: e191405, jan.-dez. 2019. ilus
Article de Anglais | LILACS, BBO - Ondontologie | ID: biblio-1087884

RÉSUMÉ

Aim: The crystallization step is required for lithium disilicate ceramics to change color, improve the mechanical properties and yield material to support mouth loading. Several furnaces could complete the crystallization process. This study evaluated the flexural and bond strength of lithium disilicate ceramics crystallized by different furnaces with the presence or not of vacum and different holding time. Methods: Forty lithium disilicate samples were divided into two groups: Programat P300 - control group with vacuum and holding time 7 minutes (CG) and FVPlus- experimental group and without vacuum and holding time 25 minutes (EG) and submitted to 2 experimental tests: 3-point flexural strength test and micro shear bond strength test (µSBS). For this test, the surface of the samples was treated and 1mm² of resin cement was applied on the surface. The samples were stored in artificial saliva over 2 time periods (24 hours: T0; 1-month storage: T1). To analyze the morphologic crystals of the ceramics tested, one representative specimen from each group were analyzed by using Scanning Electron Microscopy (SEM). Results: There was no significant difference in 3-point flexural strength test between groups CG and EG (p= 0.984). The µSBS results showed no statistical difference between groups, considering different storage time. There was no difference in the 3-point flexural strength and µSBS for lithium disilicate samples regardless of heat treatment of furnace type. The storage time had no influence on the µSBS. No differences were noted in the shape and size of these crystals when comparing the furnace analyzed by SEM images. Conclusion: Different furnaces did not influence the flexural and bond strength of lithium disilicate ceramics


Sujet(s)
Céramiques , Composés du lithium , Résistance au cisaillement
5.
Dent. press endod ; 7(3): 57-61, set.-dec. 2017. ilus
Article de Portugais | LILACS, BBO - Ondontologie | ID: biblio-877451

RÉSUMÉ

Introdução: a associação do preparo biomecânico adequado à desinfecção do canal radicular e à obturação satisfatória é importante para que o tratamento endodôntico tenha um prognóstico favorável. A complexidade anatômica dos canais radiculares é um fator limitante na instrumentação e impõe ao operador a necessidade de realizar diferentes manobras para conseguir alcançá-la. Objetivo: relatar um caso de tratamento endodôntico no dente #47, com anatomia complexa e dupla curvatura radicular, em paciente com limitada abertura de boca. Relato de caso: o preparo mecânico foi realizado utilizando-se técnica de instrumentação híbrida, com limas manuais de diferentes tipos (Kerr, Hedströen e Flexofile), brocas Gates-Glidden e limas rotatórias (sistema ProDesign S), que foram associadas na tentativa de aumentar a efetividade da limpeza dos três canais. Entre as sessões, foi utilizada medicação intracanal de hidróxido de cálcio e os canais foram obturados pela técnica de condensação lateral. Conclusão: após o estudo da literatura pertinente e a realização do caso clínico, concluiu-se que por meio da hibridização de sistemas é possível obter um tratamento endodôntico com melhor prognóstico e maior segurança. Ao utilizar o melhor de cada técnica, reforça-se a teoria de que nenhuma delas é totalmente completa e que instrumentos manuais, mesmo com o grande avanço dos aparelhos automatizados, ainda possuem seu valor e continuam sendo essenciais nos protocolos de instrumentação.


Sujet(s)
Humains , Femelle , Adulte , Agents de collage dentinaire , Endodontie/instrumentation , Endodontie/méthodes , Préparation de canal radiculaire , Traitement de canal radiculaire , Irrigation thérapeutique
6.
Prosthes. Lab. Sci ; 6(23): 62-66, abr.-jun. 2017. ilus
Article de Portugais | BBO - Ondontologie | ID: biblio-877462

RÉSUMÉ

Para obter estética e funcionalidade em prótese implantada, vários detalhes devem ser observados. Um detalhe importante em próteses do tipo protocolo é a presença de espaço para higienização. Este caso clínico relata um caso em que a paciente utilizava uma prótese do tipo protocolo superior e prótese parcial removível inferior Classe I de Kennedy. Contudo, a paciente estava insatisfeita com sua prótese superior em relação à estética e dificuldade para higienização. Durante a consulta para diagnóstico e planejamento esses problemas reportados pela pacientes ficaram evidentes: mal posicionamento dos dentes, falta de espaço para corredor bucal e desvio de linha média. foi proposto a paciente a confecção de novas próteses superior e inferior, que seguiram todos os passos necessários para alcançar estética e funcionalidade. A etapa de prova de dentes superiores foi realizada três vezes, até que estivesse ideal. Após a acrilização da prótese superior foram criadas pequenas canaletas para guiar a passagem do fio dental entre os implantes, facilitando o processo de higienização. Este caso clínico demonstra que todos os parâmetros necessários para a confecção de uma prótese total adequada devem ser respeitados durante a confecção de uma prótese do tipo protocolo sobre implantes. Além disso, a confecção das canaletas para higienização permite que o paciente realize esse processo de forma satisfatória, podendo aumentar o tempo de sucesso do tratamento.


To achieve good aesthetics and function in implant-supported dental prosthesis several details must be observed. One important detail for protocol-type prosthesis is the presence of a cleansing space. This paper reports the case of a patient with upper protocol-type prosthesis and an inferior partial Kennedy Class I removable prosthesis. however, the patient was unsatisfied with the aesthetics of the upper prosthesis as well as with the difficulty of cleaning it. During consultation for diagnosis and planning the problems reported by the patient became evident: wrong positioning of the teeth, lack of buccal corridor and midline deviation. The recommendation was to manufacture new lower and upper prostheses, following all the required steps in order to achieve satisfactory aesthetics and function. for the upper teeth try-in stages were performed, until the ideal fit was reached. After acrylic cure of the upper prosthesis was performed, furrows were created in the region between the implants, serving as guide to facilitate the passage of dental floss, making it easier to clean the prosthesis. The aim of this study was to demonstrate, that all the parameters observed in the manufacture of a conventional complete denture should be followed in the confection of protocol type prosthesis. Also, the furrows allow proper hygiene, which may increase the duration of the treatment success.


Sujet(s)
Humains , Implants dentaires , Prothèse dentaire implanto-portée , Conception d'appareil de prothèse dentaire , Prothèse dentaire complète , Hygiène buccodentaire , Prothèses et implants
7.
Braz. j. oral sci ; 15(3)July-Sept. 2016. ilus
Article de Anglais | LILACS, BBO - Ondontologie | ID: biblio-875030

RÉSUMÉ

Aim: Evaluate the masticatory performance in patients with different clinical situations: patients with natural dentition without restorative and/or orthodontic intervention (Group CG) and patients with restorations and/or orthodontic intervention (Group TG). Subjects received instruction before the experiment, related to masticatory movements. Methods: Three capsules containing the granules were delivered separately to chew for 20 seconds each, controlled by the examiner. One capsule was chewed for 20 seconds only on the left side; the second capsule was chewed for 20 seconds only on the right side; and the third capsule was chewed for 20 seconds to simulate each patient's mastication. The mean data and standard deviation of masticatory function of each patient was calculated. Results: The results obtained in this study showed that there were no statistically significant differences (P < 0.05) between both tested groups (0.0320 ± 0.00716, 0.0436 ± 0.00974). Conclusions: Patients who were submitted to orthodontic and/or restorative procedures, with balanced occlusion could be used as a control group, making easier the patient recruitment. Clinicians and researchers on masticatory performance evaluation could apply the colorimetric method. The colorimetric method was a standardize method, effective and easy to execute. (AU)


Sujet(s)
Humains , Mâle , Femelle , Colorimétrie , Denture permanente , Mastication
8.
Prosthes. Lab. Sci ; 6(21): 52-57, 2016. ilus
Article de Portugais | LILACS, BBO - Ondontologie | ID: biblio-837403

RÉSUMÉ

Os componentes dinâmicos surgiram como alternativa para reabilitar implantes inclinados em até 20°, possibilitando o restabelecimento da estética, função e reduzindo os custos do procedimento. Sendo assim, o objetivo deste trabalho é apresentar um relato de caso utilizando esses componentes. Durante o exame clínico foi diagnosticado que os implantes apresentavam profundidade gengival rasa, inclinação e paralelismo desfavoráveis. Dessa forma, foi optado pela utilização de pilares retos com componentes dinâmicos, que irão corrigir a inclinação do orifício de acesso do parafuso da prótese definitiva.


Dynamic components were created as an alternative to rehabilitate tilted implants until 20º angled. This component allows aesthetic and function rehabilitation with lower cost comparing to angled abutments. The aim of this study was to present a case report us-ing these dynamic components. The patient presented tilted implants with gingival shallow depth, with unfavourable parallelism. Thus, straight abutment and dynamic components were concomitantly used to correct the access screw hole inclination of final the prosthesis.


Sujet(s)
Humains , Adulte d'âge moyen , Implants dentaires , Prothèse dentaire implanto-portée , Dentisterie esthétique , Rééducation buccale/méthodes , Ajustement occlusal/méthodes , Dimension verticale
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE