Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 333
Filtrer
2.
Nat Med ; 2024 Jul 08.
Article de Anglais | MEDLINE | ID: mdl-38977913

RÉSUMÉ

Pulsed field ablation (PFA) is an emerging technology for the treatment of atrial fibrillation (AF), for which pre-clinical and early-stage clinical data are suggestive of some degree of preferentiality to myocardial tissue ablation without damage to adjacent structures. Here in the MANIFEST-17K study we assessed the safety of PFA by studying the post-approval use of this treatment modality. Of the 116 centers performing post-approval PFA with a pentaspline catheter, data were received from 106 centers (91.4% participation) regarding 17,642 patients undergoing PFA (mean age 64, 34.7% female, 57.8% paroxysmal AF and 35.2% persistent AF). No esophageal complications, pulmonary vein stenosis or persistent phrenic palsy was reported (transient palsy was reported in 0.06% of patients; 11 of 17,642). Major complications, reported for ~1% of patients (173 of 17,642), were pericardial tamponade (0.36%; 63 of 17,642) and vascular events (0.30%; 53 of 17,642). Stroke was rare (0.12%; 22 of 17,642) and death was even rarer (0.03%; 5 of 17,642). Unexpected complications of PFA were coronary arterial spasm in 0.14% of patients (25 of 17,642) and hemolysis-related acute renal failure necessitating hemodialysis in 0.03% of patients (5 of 17,642). Taken together, these data indicate that PFA demonstrates a favorable safety profile by avoiding much of the collateral damage seen with conventional thermal ablation. PFA has the potential to be transformative for the management of patients with AF.

3.
Int J Cardiol ; : 132333, 2024 Jul 05.
Article de Anglais | MEDLINE | ID: mdl-38972492

RÉSUMÉ

OBJECTIVE: Pregnancy can trigger maternal tachycardias, and the onset of recurrent or incessant focal atrial tachycardia (AT) can lead to tachycardia-induced cardiomyopathy. Medical interventions are commonly employed, but they carry potential fetal and maternal risks. Catheter ablation (CA), particularly with non-fluoroscopic navigation systems, may be considered as an alternative. This systematic review aims to explore the feasibility and outcomes of CA for focal AT during pregnancy. METHODS: A thorough literature search was conducted until September 30th, 2023, on PubMed, Embase, and Cochrane databases. Included articles described maternal focal ATs diagnosed through electrophysiological studies and treated with CA. Data derived from these studies were organized into tables and subsequently analyzed. RESULTS: Out of 278 papers reviewed, 15 articles involving 24 patients were retrieved. CA, utilizing radiofrequency energy achieved acute success in 95.8% of cases. Sixteen patients (66.7%) underwent complete fluoroless procedures, with two adverse events directly related to the procedure reported. Long-term follow-up revealed minimal AT recurrences, with a 0.06% arrhythmia burden in one case. CONCLUSION: Focal ATs during pregnancy can be incessant and refractory to medical intervention, precipitating an acute decline in left ventricular ejection fraction. In this setting, CA emerges as an efficacious treatment modality, particularly in cases of tachycardia-induced cardiomyopathies. Whenever feasible, it is advisable to perform these procedures with minimal or no fluoroscopy guidance. Larger studies are needed to establish the safety and the efficacy of CA for focal ATs during pregnancy, as current research consists of case reports or small case series.

4.
Heart Rhythm ; 2024 Jun 20.
Article de Anglais | MEDLINE | ID: mdl-38908459

RÉSUMÉ

BACKGROUND: Studies evaluating the systematic use of cardiac computer tomography (CCT) for the pre-procedural assessment of myocardial fibrosis are limited and their implementation in the electrophysiology workflow has not been extensively described. OBJECTIVE: To explore the degree of concordance between cardiac fibrosis evaluated by CCT compared to electroanatomical mapping (EAM) in patients undergoing endo-epicardial ventricular tachycardia (VT) ablation. METHODS: From November-2017 to December-2021, patients undergoing endo-epicardial VT catheter ablation (CA) with CCT as the only source of pre-procedural scar assessment were prospectively enrolled. After image integration, myocardial fibrosis detected with CCT was compared with low voltage areas identified by endo-epicardial EAM. Post-procedural VT recurrences of this approach were evaluated after at least one-year follow-up. RESULTS: 35 patients (mean age 60.7±13.2 years, 94.2% males) were enrolled. The most common underlying arrhythmic substrate was dilated cardiomyopathy (48.6%). CCT was employed for contraindications to cardiac magnetic resonance, as unstable VTs (31.4%) or non-conditional ICDs (28.8%), but also for patients' and operators' preferences (14.3%-25.7%). Myocardial fibrosis was correctly identified by CCT and EAM, with strong agreement between these two techniques, both overall (Cohen's Kappa for agreement=0.933) and in per-segment analysis (K ranging from 0.796 to 1.0). Ischemic patients showed the best correlation (K=1.000) while myocarditis showed the worst (K=0.750). After a median follow-up of 14 [12-24] months, 1-year freedom from recurrences was achieved in 74.3% patients; overall freedom from recurrences was 60.0%. CONCLUSIONS: A CCT-based pre-procedural assessment pre-VT ablation is feasible, showing high diagnostic concordance with EAM in detecting myocardial fibrosis.

5.
JACC Adv ; 3(3): 100832, 2024 Mar.
Article de Anglais | MEDLINE | ID: mdl-38938828

RÉSUMÉ

Background: Patients with likely pathogenic/pathogenic desmoplakin (DSP) variants are poorly characterized. Some of them meet diagnostic criteria for arrhythmogenic right ventricular cardiomyopathy (ARVC), but it is unclear how risk stratification strategies for ARVC perform in this setting. Objectives: The purpose of this study was to characterize arrhythmic outcomes and to test the performance of the recently validated ARVC risk calculator in patients with DSP likely pathogenic/pathogenic variants fulfilling definite 2010 ARVC Task Force Criteria (DSP-TFC+). Methods: DSP-TFC+ patients were enrolled from 20 institutions across 3 continents. Ventricular arrhythmias (VA), defined as a composite of sustained ventricular tachycardia (VT), appropriate implantable cardioverter defibrillator therapies, and ventricular fibrillation/sudden cardiac death events in follow-up, were reported as the primary outcome. We tested the performance of the ARVC risk calculator for VA prediction, reporting c-statistics. Results: Among 252 DSP-TFC+ patients (age 39.6 ± 16.9 years, 35.3% male), 94 (37.3%) experienced VA over 44.5 [IQR: 19.6-78.3] months. Patients with left ventricle involvement (n = 194) were at higher VA risk (log-rank P = 0.0239). History of nonsustained VT (aHR 2.097; P = 0.004) showed the strongest association with VA occurrence during the first 5-year follow-up. Neither age (P = 0.723) nor male sex (P = 0.200) was associated with VAs at follow-up. In 204 patients without VA at diagnosis, incident VA rate was high (32.8%; 7.37%/y). The ARVC risk calculator performed poorly overall (c-statistic 0.604 [0.594-0.614]) and very poorly in patients with left ventricular disease (c-statistic 0.558 [0.556-0.560]). Conclusions: DSP-TFC+ patients are at substantial risk for VAs. The ARVC risk calculator performs poorly in DSP-TFC+ patients suggesting need for a gene-specific risk algorithm. Meanwhile, DSP-TFC+ patients with nonsustained VT should be considered as high-risk.

6.
Europace ; 26(5)2024 05 02.
Article de Anglais | MEDLINE | ID: mdl-38743765

RÉSUMÉ

Imaging using cardiac computed tomography (CT) or magnetic resonance (MR) imaging has become an important option for anatomic and substrate delineation in complex atrial fibrillation (AF) and ventricular tachycardia (VT) ablation procedures. Computed tomography more common than MR has been used to detect procedure-associated complications such as oesophageal, cerebral, and vascular injury. This clinical consensus statement summarizes the current knowledge of CT and MR to facilitate electrophysiological procedures, the current value of real-time integration of imaging-derived anatomy, and substrate information during the procedure and the current role of CT and MR in diagnosing relevant procedure-related complications. Practical advice on potential advantages of one imaging modality over the other is discussed for patients with implanted cardiac rhythm devices as well as for planning, intraprocedural integration, and post-interventional management in AF and VT ablation patients. Establishing a team of electrophysiologists and cardiac imaging specialists working on specific details of imaging for complex ablation procedures is key. Cardiac magnetic resonance (CMR) can safely be performed in most patients with implanted active cardiac devices. Standard procedures for pre- and post-scanning management of the device and potential CMR-associated device malfunctions need to be in place. In VT patients, imaging-specifically MR-may help to determine scar location and mural distribution in patients with ischaemic and non-ischaemic cardiomyopathy beyond evaluating the underlying structural heart disease. Future directions in imaging may include the ability to register multiple imaging modalities and novel high-resolution modalities, but also refinements of imaging-guided ablation strategies are expected.


Sujet(s)
Consensus , Imagerie par résonance magnétique , Tomodensitométrie , Humains , Ablation par cathéter , Techniques électrophysiologiques cardiaques , Tachycardie ventriculaire/chirurgie , Tachycardie ventriculaire/imagerie diagnostique , Fibrillation auriculaire/chirurgie , Fibrillation auriculaire/imagerie diagnostique , Fibrillation auriculaire/physiopathologie , Valeur prédictive des tests , Europe , Résultat thérapeutique
7.
JACC Cardiovasc Interv ; 17(11): 1311-1321, 2024 Jun 10.
Article de Anglais | MEDLINE | ID: mdl-38795093

RÉSUMÉ

BACKGROUND: Left atrial appendage occlusion (LAAO) provides mechanical cardioembolic protection for atrial fibrillation (AF) patients who cannot use oral anticoagulation therapy (OAT). Patients with a thrombotic event despite OAT are at high risk for recurrence and may also benefit from LAAO. OBJECTIVES: This study sought to investigate the efficacy of LAAO in AF patients with a thrombotic event on OAT compared to: 1) LAAO in AF patients with a contraindication for OAT; and 2) historical data. METHODS: The international LAAO after stroke despite oral anticoagulation (STR-OAC LAAO) collaboration included patients who underwent LAAO because of thrombotic events on OAT. This cohort underwent propensity score matching and was compared to the EWOLUTION (Evaluating Real-Life Clinical Outcomes in Atrial Fibrillation Patients Receiving the WATCHMAN Left Atrial Appendage Closure Technology) registry, which represents patients who underwent LAAO because of OAT contraindications. The primary outcome was ischemic stroke. Event rates were compared between cohorts and with historical data without OAT, yielding relative risk reductions based on risk scores. RESULTS: Analysis of 438 matched pairs revealed no significant difference in the ischemic stroke rate between the STR-OAC LAAO and EWOLUTION cohorts (2.5% vs 1.9%; HR: 1.37; 95% CI: 0.72-2.61). STR-OAC LAAO patients exhibited a higher thromboembolic risk (HR: 1.71; 95% CI: 1.04-2.83) but lower bleeding risk (HR: 0.39; 95% CI: 0.18-0.88) compared to EWOLUTION patients. The mortality rate was slightly higher in EWOLUTION (4.3% vs 6.9%; log-rank P = 0.028). Relative risk reductions for ischemic stroke were 70% and 78% in STR-OAC LAAO and EWOLUTION, respectively, compared to historical data without OAT. CONCLUSIONS: LAAO in patients with a thrombotic event on OAT demonstrated comparable stroke rates to the OAT contraindicated population in EWOLUTION. The thromboembolic event rate was higher and the bleeding rate lower, reflecting the intrinsically different risk profile of both populations. Until randomized trials are available, LAAO may be considered in patients with an ischemic event on OAT.


Sujet(s)
Anticoagulants , Auricule de l'atrium , Fibrillation auriculaire , Cathétérisme cardiaque , Contre-indications aux médicaments , Accident vasculaire cérébral ischémique , Enregistrements , Humains , Auricule de l'atrium/physiopathologie , Auricule de l'atrium/imagerie diagnostique , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/complications , Fibrillation auriculaire/mortalité , Fibrillation auriculaire/traitement médicamenteux , Fibrillation auriculaire/thérapie , Femelle , Mâle , Anticoagulants/effets indésirables , Anticoagulants/administration et posologie , Sujet âgé , Facteurs de risque , Appréciation des risques , Sujet âgé de 80 ans ou plus , Facteurs temps , Administration par voie orale , Accident vasculaire cérébral ischémique/prévention et contrôle , Accident vasculaire cérébral ischémique/mortalité , Accident vasculaire cérébral ischémique/diagnostic , Accident vasculaire cérébral ischémique/étiologie , Cathétérisme cardiaque/effets indésirables , Cathétérisme cardiaque/instrumentation , Cathétérisme cardiaque/mortalité , Échec thérapeutique , Hémorragie/induit chimiquement , Récidive , Adulte d'âge moyen , Études rétrospectives , Europe
8.
Europace ; 26(5)2024 May 02.
Article de Anglais | MEDLINE | ID: mdl-38696701

RÉSUMÉ

AIMS: Women have been historically underrepresented in implantable cardioverter-defibrillator (ICD) trials. No data on sex differences regarding subcutaneous ICDs (S-ICD) carriers have been described. Aim of our study was to investigate sex-related differences among unselected S-ICD recipients. METHODS AND RESULTS: Consecutive patients enrolled in the multicentre, international i-SUSI registry were analysed. Comparisons between sexes were performed using a 1:1 propensity matching adjusted analysis for age, body mass index (BMI), left ventricular function, and substrate. The primary outcome was the rate of appropriate shocks during follow-up. Inappropriate shocks and other device-related complications were deemed secondary outcomes. A total of 1698 patients were extracted from the i-SUSI registry; 399 (23.5%) were females. After propensity matching, two cohorts of 374 patients presenting similar baseline characteristics were analysed. Despite similar periprocedural characteristics and a matched BMI, women resulted at lower risk of conversion failure as per PRAETORIAN score (73.4% vs. 81.3%, P = 0.049). Over a median follow-up time of 26.5 [12.7-42.5] months, appropriate shocks were more common in the male cohort (rate/year 3.4% vs. 1.7%; log-rank P = 0.049), while no significant differences in device-related complications (rate/year: 6.3% vs. 5.8%; log-rank P = 0.595) and inappropriate shocks (rate/year: 4.3% vs. 3.1%; log-rank P = 0.375) were observed. After controlling for confounders, sex remained significantly associated with the primary outcome (aHR 1.648; CI 0.999-2.655, P = 0.048), while not resulting predictor of inappropriate shocks and device-related complications. CONCLUSION: In a propensity-matched cohort of S-ICD recipients, women are less likely to experience appropriate ICD therapy, while not showing higher risk of device-related complications. CLINICAL TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT0473876.


Sujet(s)
Défibrillateurs implantables , Défibrillation , Score de propension , Enregistrements , Humains , Femelle , Mâle , Adulte d'âge moyen , Sujet âgé , Facteurs sexuels , Défibrillation/instrumentation , Défibrillation/effets indésirables , Facteurs de risque , Résultat thérapeutique , Troubles du rythme cardiaque/thérapie , Appréciation des risques , Europe , Facteurs temps , Mort subite cardiaque/prévention et contrôle
10.
Article de Anglais | MEDLINE | ID: mdl-38814525

RÉSUMÉ

BACKGROUND: Recent data on pulsed field ablation (PFA) for atrial fibrillation (AF) ablation suggest a progressive reduction in procedural times. Real-world data regarding the relationship between the learning curve of PFA and clinical outcomes are scarce. The objective was to evaluate the PFA learning curve and its impact on acute outcomes. METHODS: Consecutive patients undergoing AF ablation with the FARAPULSE™ PFA system were included in a prospective, non-randomized multicenter study. Procedural times were stratified on the operators' learning curve. Comparative analysis of skin-to-skin time was conducted with radiofrequency (RF) and cryoablation (CB) pulmonary vein isolation (PVI) procedures performed by the same operators in the previous year. RESULTS: Among 752 patients, 35.1% were females, and 66.9% had paroxysmal AF; mean age was 62.2 ± 10 years. A total of 62.5% of procedures were performed by operators with > 20 PFA procedures. Both time to PVI (25.6 ± 10 min vs 16.5 ± 8, p < 0.0001) and fluoroscopy time (19.8 ± 8 min vs 15.9 ± 8 min, p = 0.0045) significantly improved after 10 associated with consistent linear trend towards procedural time reduction (R2 0.92-0.68 across various procedural metrics). Current PFA skin-to-skin time was lower than the historical skin-to-skin one in 217 (62.4%) procedures; it was similar in 112 (32.2%) cases and higher than the historical skin-to-skin one in 19 (5.5%). No major complications were reported. CONCLUSIONS: In this nationwide multicentric experience, the novel PFA system proved to be fast, safe, and acutely effective in both paroxysmal and persistent AF patients. The learning curve appears to be rapid, as improvements in procedural parameters were observed after only a few procedures. CLINICAL TRIAL REGISTRATION: Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA). URL: http://clinicaltrials.gov/ Identifier: NCT05617456.

11.
Europace ; 26(4)2024 Mar 30.
Article de Anglais | MEDLINE | ID: mdl-38584394

RÉSUMÉ

AIMS: Catheter ablation (CA) of ventricular tachycardia (VT) has become an important tool to improve clinical outcomes in patients with appropriate transvenous implantable cardioverter defibrillator (ICD) shocks. The aim of our analysis was to test whether VT ablation (VTA) impacts long-term clinical outcomes even in subcutaneous ICD (S-ICD) carriers. METHODS AND RESULTS: International Subcutaneous Implantable Cardioverter Defibrillator (iSUSI) registry patients who experienced either an ICD shock or a hospitalization for monomorphic VT were included in this analysis. Based on an eventual VTA after the index event, patients were divided into VTA+ vs. VTA- cohorts. Primary outcome of the study was the occurrence of a combination of device-related appropriate shocks, monomorphic VTs, and cardiovascular mortality. Secondary outcomes were addressed individually. Among n = 1661 iSUSI patients, n = 211 were included: n = 177 experiencing ICD shocks and n = 34 hospitalized for VT. No significant differences in baseline characteristics were observed. Both the crude and the yearly event rate of the primary outcome (5/59 and 3.8% yearly event rate VTA+ vs. 41/152 and 16.4% yearly event rate in the VTA-; log-rank: P value = 0.0013) and the cardiovascular mortality (1/59 and 0.7% yearly event rate VTA+ vs. 13/152 and 4.7% yearly event rate VTA-; log-rank P = 0.043) were significantly lower in the VTA + cohort. At multivariate analysis, VTA was the only variable remaining associated with a lower incidence of the primary outcome [adjusted hazard ratio 0.262 (0.100-0.681), P = 0.006]. CONCLUSION: In a real-world registry of S-ICD carriers, the combined study endpoint of arrhythmic events and cardiovascular mortality was lower in the patient cohort undergoing VTA at long-term follow-up. CLINICALTRIALS.GOV IDENTIFIER: NCT0473876.


Sujet(s)
Ablation par cathéter , Défibrillateurs implantables , Tachycardie ventriculaire , Humains , Troubles du rythme cardiaque/étiologie , Ablation par cathéter/effets indésirables , Ablation par cathéter/méthodes , Défibrillation/effets indésirables , Tachycardie ventriculaire/diagnostic , Tachycardie ventriculaire/chirurgie , Résultat thérapeutique
13.
J Clin Med ; 13(5)2024 Feb 22.
Article de Anglais | MEDLINE | ID: mdl-38592089

RÉSUMÉ

(1) Background/Objective Balloon-guided catheter ablation (CA) has emerged as an alternative option for atrial fibrillation (AF) management. The recent introduction of a novel-size adjustable second-generation cryoballoon (CB) system offers innovations, but clinical outcomes remain unexplored. This study aims to assess the acute performance of the POLARx FIT™ CB system in AFCA. (2) Methods: Consecutive patients undergoing AF ablation with the POLARx FIT™ CB system in our center were included. The primary outcome was the rate of 31 mm balloon-size utilization, with secondary outcomes including acute pulmonary vein isolation (PVI) rate, periprocedural complications, and in-hospital AF recurrences. (3) Results: Twenty-four patients with a mean age of 59.5 years, predominantly male (87.5%), and exhibiting paroxysmal AF (91.7%) were enrolled. Procedural characteristics demonstrated a high acute success rate (100% PV isolation) with a favorable safety profile. Notably, the 31 mm CB configuration was utilized in 51% of applications, showcasing its adaptability in challenging anatomies. No major complications occurred, with two patients experiencing in-hospital self-limiting AF recurrences. (4) Conclusions: This study represents the first comprehensive assessment of the POLARx FIT™ CB system in AF ablation. While acknowledging the study's limitations, this novel CB emerges as a promising tool, warranting further exploration in larger studies with extended follow-up periods.

14.
Europace ; 26(4)2024 Mar 30.
Article de Anglais | MEDLINE | ID: mdl-38587017

RÉSUMÉ

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society .


Sujet(s)
Fibrillation auriculaire , Ablation par cathéter , Humains , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/chirurgie , Amérique latine , Résultat thérapeutique , Cathéters , Asie , Ablation par cathéter/effets indésirables , Ablation par cathéter/méthodes
15.
Article de Anglais | MEDLINE | ID: mdl-38609733

RÉSUMÉ

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society (HRS), the Asia Pacific HRS, and the Latin American HRS.

16.
Heart Rhythm ; 2024 Apr 08.
Article de Anglais | MEDLINE | ID: mdl-38597857

RÉSUMÉ

In the last three decades, ablation of atrial fibrillation (AF) has become an evidence-based safe and efficacious treatment for managing the most common cardiac arrhythmia. In 2007, the first joint expert consensus document was issued, guiding healthcare professionals involved in catheter or surgical AF ablation. Mounting research evidence and technological advances have resulted in a rapidly changing landscape in the field of catheter and surgical AF ablation, thus stressing the need for regularly updated versions of this partnership which were issued in 2012 and 2017. Seven years after the last consensus, an updated document was considered necessary to define a contemporary framework for selection and management of patients considered for or undergoing catheter or surgical AF ablation. This consensus is a joint effort from collaborating cardiac electrophysiology societies, namely the European Heart Rhythm Association, the Heart Rhythm Society, the Asia Pacific Heart Rhythm Society, and the Latin American Heart Rhythm Society.

17.
Eur Heart J ; 45(14): 1255-1265, 2024 Apr 07.
Article de Anglais | MEDLINE | ID: mdl-38445836

RÉSUMÉ

BACKGROUND AND AIMS: Available data on continuous rhythm monitoring by implantable loop recorders (ILRs) in patients with Brugada syndrome (BrS) are scarce. The aim of this multi-centre study was to evaluate the diagnostic yield and clinical implication of a continuous rhythm monitoring strategy by ILRs in a large cohort of BrS patients and to assess the precise arrhythmic cause of syncopal episodes. METHODS: A total of 370 patients with BrS and ILRs (mean age 43.5 ± 15.9, 33.8% female, 74.1% symptomatic) from 18 international centers were included. Patients were followed with continuous rhythm monitoring for a median follow-up of 3 years. RESULTS: During follow-up, an arrhythmic event was recorded in 30.7% of symptomatic patients [18.6% atrial arrhythmias (AAs), 10.2% bradyarrhythmias (BAs), and 7.3% ventricular arrhythmias (VAs)]. In patients with recurrent syncope, the aetiology was arrhythmic in 22.4% (59.3% BAs, 25.0% VAs, and 15.6% AAs). The ILR led to drug therapy initiation in 11.4%, ablation procedure in 10.9%, implantation of a pacemaker in 2.5%, and a cardioverter-defibrillator in 8%. At multivariate analysis, the presence of symptoms [hazard ratio (HR) 2.5, P = .001] and age >50 years (HR 1.7, P = .016) were independent predictors of arrhythmic events, while inducibility of ventricular fibrillation at the electrophysiological study (HR 9.0, P < .001) was a predictor of VAs. CONCLUSIONS: ILR detects arrhythmic events in nearly 30% of symptomatic BrS patients, leading to appropriate therapy in 70% of them. The most commonly detected arrhythmias are AAs and BAs, while VAs are detected only in 7% of cases. Symptom status can be used to guide ILR implantation.


Sujet(s)
Syndrome de Brugada , Défibrillateurs implantables , Pacemaker , Femelle , Humains , Mâle , Adulte d'âge moyen , Troubles du rythme cardiaque/complications , Troubles du rythme cardiaque/diagnostic , Syndrome de Brugada/complications , Syndrome de Brugada/diagnostic , Syndrome de Brugada/thérapie , Électrocardiographie/méthodes , Électrocardiographie ambulatoire/méthodes , Adulte
18.
J Cardiovasc Electrophysiol ; 35(6): 1101-1111, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38519418

RÉSUMÉ

INTRODUCTION: Limited data exist on pulsed-field ablation (PFA) in patients with persistent atrial fibrillation (PeAF) undergoing left atrial posterior wall isolation (LAPWI). METHODS: The Advanced TecHnologies For SuccEssful AblatioN of AF in Clinical Practice (ATHENA) prospective registry included consecutive patients referred for PeAF catheter ablation at 9 Italian centers, treated with the FARAPULSETM-PFA system. The primary efficacy and safety study endpoints were the acute LAPWI rate, freedom from arrhythmic recurrences and the incidence of major periprocedural complications. Patients undergoing pulmonary vein isolation (PVI) alone, PWI + LAPWI and redo procedures were compared. RESULTS: Among 249 patients, 21.7% had long-standing PeAF, 79.5% were male; mean age was 63 ± 9 years. LAPWI was performed in 57.6% of cases, with 15.3% being redo procedures. Median skin-to-skin times (PVI-only 68 [60-90] vs. PVI + LAPWI 70 [59-88] mins) did not differ between groups. 45.8% LAPWI cases were approached with a 3D-mapping system, and 37.3% with intracardiac echocardiography. LAPWI was achieved in all patients by means of PFA alone, in 88.8% cases at first pass. LAPWI was validated either by an Ultrahigh-density mapping system or by recording electrical activity + pacing maneuvers. No major complications occurred, while 2.4% minor complications were detected. During a median follow-up of 273 [191-379] days, 41 patients (16.5%) experienced an arrhythmic recurrence after the 90-day blanking period, with a mean time to recurrence of 223 ± 100 days and no differences among ablation strategies. CONCLUSION: LAPWI with PFA demonstrates feasibility, rapidity, and safety in real-world practice, offering a viable alternative for PeAF patients. LAPWI is achievable even with a fluoroscopy-only method and does not significantly extend overall procedural times.


Sujet(s)
Potentiels d'action , Fibrillation auriculaire , Ablation par cathéter , Rythme cardiaque , Veines pulmonaires , Récidive , Enregistrements , Humains , Fibrillation auriculaire/chirurgie , Fibrillation auriculaire/physiopathologie , Fibrillation auriculaire/diagnostic , Mâle , Femelle , Veines pulmonaires/chirurgie , Veines pulmonaires/physiopathologie , Adulte d'âge moyen , Ablation par cathéter/effets indésirables , Sujet âgé , Études prospectives , Facteurs temps , Italie , Facteurs de risque , Atrium du coeur/physiopathologie , Atrium du coeur/chirurgie , Résultat thérapeutique , Survie sans progression
19.
Eur Heart J ; 45(14): 1241-1251, 2024 Apr 07.
Article de Anglais | MEDLINE | ID: mdl-38426911

RÉSUMÉ

BACKGROUND AND AIMS: Prior reports have demonstrated a favourable safety and efficacy profile of the Micra leadless pacemaker over mid-term follow-up; however, long-term outcomes in real-world clinical practice remain unknown. Updated performance of the Micra VR leadless pacemaker through five years from the worldwide post-approval registry (PAR) was assessed. METHODS: All Micra PAR patients undergoing implant attempts were included. Endpoints included system- or procedure-related major complications and system revision rate for any cause through 60 months post-implant. Rates were compared through 36 months post-implant to a reference dataset of 2667 transvenous pacemaker patients using Fine-Gray competing risk models. RESULTS: 1809 patients were enrolled between July 2015 and March 2018 and underwent implant attempts from 179 centres in 23 countries with a median follow-up period of 51.1 months (IQR: 21.6-64.2). The major complication rate at 60 months was 4.5% [95% confidence interval (CI): 3.6%-5.5%] and was 4.1% at 36 months, which was significantly lower than the 8.5% rate observed for transvenous systems (HR: .47, 95% CI: .36-.61; P < .001). The all-cause system revision rate at 60 months was 4.9% (95% CI: 3.9%-6.1%). System revisions among Micra patients were mostly for device upgrades (41.2%) or elevated thresholds (30.6%). There were no Micra removals due to infection noted over the duration of follow-up. At 36 months, the system revision rate was significantly lower with Micra vs. transvenous systems (3.2% vs. 6.6%, P < .001). CONCLUSIONS: Long-term outcomes with the Micra leadless pacemaker continue to demonstrate low rates of major complications and system revisions and an extremely low incidence of infection.


Sujet(s)
Troubles du rythme cardiaque , Pacemaker , Humains , Troubles du rythme cardiaque/thérapie , Troubles du rythme cardiaque/étiologie , Résultat thérapeutique , Conception d'appareillage , Pacemaker/effets indésirables , Enregistrements , Entraînement électrosystolique/effets indésirables
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...