Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 527
Filtrer
2.
Am Heart J ; 2024 Aug 07.
Article de Anglais | MEDLINE | ID: mdl-39121916

RÉSUMÉ

BACKGROUND: About half of patients with severe aortic stenosis present with concomitant coronary artery disease. The optimal timing of percutaneous coronary intervention (PCI) and transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and concomitant coronary artery disease remains unknown. STUDY DESIGN: The TAVI PCI trial is a prospective, international, multicenter, randomized, two-arm, open-label study planning to enroll a total of 986 patients. It is designed to investigate whether the strategy "angiography-guided complete revascularization after (within 1-45 days) TAVI" is non-inferior to the strategy "angiography-guided complete revascularization before (within 1-45 days) TAVI" using the Edwards SAPIEN 3 or 3 Ultra Transcatheter Heart Valve™ in patients with severe aortic stenosis and concomitant coronary artery disease. Patients are randomized in a 1:1 ratio to one of the two treatment strategies. The primary end point is a composite of all-cause death, non-fatal myocardial infarction, ischemia-driven revascularization, rehospitalization (valve- or procedure-related including heart failure), or life-threatening/disabling or major bleeding at 1 year. CONCLUSIONS: The TAVI PCI trial tests the hypothesis that the strategy "PCI after TAVI" is non-inferior to the strategy "PCI before TAVI" in patients with severe aortic stenosis and concomitant coronary artery disease.

3.
Article de Anglais | MEDLINE | ID: mdl-38970592

RÉSUMÉ

Inter-echocardiography core laboratory (ECL) harmonization is pivotal to consider data from different ECLs interchangeable. On the basis of the experience of the first trans-Atlantic harmonization of 2 established ECLs in the field of transcatheter aortic valve replacement (TAVR) trials, this review describes the harmonized ECL methodology in analyzing and adjudicating the post-TAVR echocardiographic endpoints according to Valve Academic Research Consortium 3 definitions. This review presents the feasibility and intra- and inter-ECL reproducibility, explains the root cause of potential important inter-ECL variability, and formulates ECL recommendations for optimal post-TAVR echocardiographic image acquisition. The implementation of inter-ECL harmonization may further define the best practice of ECLs and have logistic and regulatory implications for the realization of future TAVR trials.

4.
Article de Anglais | MEDLINE | ID: mdl-38970594

RÉSUMÉ

3-dimensional (3D) intracardiac echocardiography (ICE) is emerging as a promising complement and potential alternative to transesophageal echocardiography for imaging guidance in structural heart interventions. To establish standardized practices, our multidisciplinary expert position statement serves as a comprehensive guide for the appropriate indications and utilization of 3D-ICE in various structural heart procedures. The paper covers essential aspects such as the fundamentals of 3D-ICE imaging, basic views, and workflow recommendations specifically tailored for ICE-guided structural heart procedures, such as transeptal puncture, device closure of intracardiac structures, and transcatheter mitral and tricuspid valve interventions. Current challenges, future directions, and training requirements to ensure operator proficiency are also discussed, thereby promoting the safety and efficacy of this innovative imaging modality to support expanding its future clinical applications.

5.
JAMA Cardiol ; 2024 Jul 10.
Article de Anglais | MEDLINE | ID: mdl-38985461

RÉSUMÉ

Importance: In older patients with atrial fibrillation who take anticoagulants for stroke prevention, bleeding is increased compared with younger patients, thus, clinicians frequently prescribe lower than recommended doses in older patients despite limited randomized data. Objective: To evaluate ischemic and bleeding outcomes in patients 80 years and older with atrial fibrillation receiving edoxaban, 60 mg vs 30 mg, and edoxaban, 30 mg vs warfarin. Design, Setting, and Participants: The ENGAGE AF-TIMI 48 trial (Effective Anticoagulation With Factor Xa Next Generation in Atrial Fibrillation-Thrombolysis in Myocardial Infarction 48) was a parallel-design, double-blind, global clinical trial that randomized patients with atrial fibrillation to either one of 2 edoxaban dosing regimens or warfarin. This secondary analysis focused on patients 80 years or older without dose-reduction criteria receiving edoxaban, 60 mg vs 30 mg, as well as patients with or without dose-reduction criteria receiving edoxaban, 30 mg, vs warfarin. Study data were analyzed between October 2022 and December 2023. Interventions: Oral edoxaban, 30 mg once daily; edoxaban, 60 mg once daily; or warfarin. Main Outcomes and Measures: Primary net clinical outcome of death, stroke or systemic embolism, and major bleeding and each individual component. Results: The current analysis included 2966 patients 80 years and older (mean [SD] age, 83 [2.7] years; 1671 male [56%]). Among 1138 patients 80 years and older without dose-reduction criteria, those receiving edoxaban, 60 mg vs 30 mg, had more major bleeding events (hazard ratio [HR], 1.57; 95% CI, 1.04-2.38; P = .03), particularly gastrointestinal hemorrhage (HR, 2.24; 95% CI, 1.29-3.90; P = .004), with no significant difference in efficacy end points. Findings were supported by analyses of endogenous factor Xa inhibition, a marker of anticoagulant effect, which was comparable between younger patients receiving edoxaban, 60 mg, and older patients receiving edoxaban, 30 mg. In 2406 patients 80 years and older with or without dose-reduction criteria, patients receiving edoxaban, 30 mg, vs warfarin had lower rates of the primary net clinical outcome (HR, 0.78; 95% CI, 0.68-0.91; P = .001), major bleeding (HR, 0.59; 95% CI, 0.45-0.77; P < .001), and death (HR, 0.83; 95% CI, 0.70-1.00; P = .046), whereas rates of stroke or systemic embolism were comparable. Conclusions and Relevance: In this post hoc analysis of the ENGAGE AF-TIMI 48 randomized clinical trial, in patients 80 years and older with atrial fibrillation, major bleeding events were lower in patients randomized to receive edoxaban, 30 mg per day, compared with either edoxaban, 60 mg per day (in patients without dose-reduction criteria), or warfarin (irrespective of dose-reduction status), without an offsetting increase in ischemic events. These data support the concept that lower-dose anticoagulants, such as edoxaban, 30 mg, may be considered in older patients with atrial fibrillation even in the absence of dose-reduction criteria. Trial Registration: ClinicalTrials.gov Identifier: NCT00781391.

6.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Article de Anglais | MEDLINE | ID: mdl-38986659

RÉSUMÉ

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Sujet(s)
Insuffisance aortique , Valve aortique , Prothèse valvulaire cardiaque , Conception de prothèse , Enregistrements , Indice de gravité de la maladie , Remplacement valvulaire aortique par cathéter , Humains , Insuffisance aortique/physiopathologie , Insuffisance aortique/mortalité , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Femelle , Mâle , Études rétrospectives , Sujet âgé , Résultat thérapeutique , Sujet âgé de 80 ans ou plus , Facteurs de risque , Valve aortique/chirurgie , Valve aortique/physiopathologie , Valve aortique/imagerie diagnostique , Facteurs temps , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/mortalité , Remplacement valvulaire aortique par cathéter/instrumentation , Réadmission du patient , Récupération fonctionnelle , Europe , Défaillance cardiaque/mortalité , Défaillance cardiaque/thérapie , Défaillance cardiaque/physiopathologie , Défaillance cardiaque/diagnostic , Hémodynamique
7.
Am J Cardiol ; 227: 98-104, 2024 Jul 18.
Article de Anglais | MEDLINE | ID: mdl-39032588

RÉSUMÉ

In patients with prevalent or incident atrial fibrillation (AF) after successful transcatheter aortic valve implantation (TAVI) enrolled in the EdoxabaN Versus standard of care and theIr effectS on clinical outcomes in pAtients havinG undergonE Transcatheter Aortic Valve Implantation - in Atrial Fibrillation (ENVISAGE-TAVI AF) trial, the incidence of ischemic stroke (IS) and any stroke was numerically less in the edoxaban group than in the vitamin K antagonist (VKA) group. The present study aimed to identify risk factors associated with IS in an on-treatment subanalysis in patients from ENVISAGE-TAVI AF who received ≥1 dose of edoxaban or VKA. Baseline patient characteristics were compared in patients with and those without IS. Numerical variables were compared using a 1-way analysis of variance; categorical variables were compared using Fisher's exact test. Stepwise Cox regression determined patient characteristics associated with the first IS event. Of 1,377 patients, 41 (3.0%) experienced an IS, and 1,336 (97.0%) did not; baseline demographics and clinical characteristics were well balanced between groups. Most ISs occurred within 180 days of TAVI for edoxaban (57.9%) and VKA (68.2%). The rate of IS was 2.0/100 person-years for edoxaban versus 2.7/100 person-years for VKA. Independently associated with IS were history of systemic embolic events (hazard ratio 2.96, 95% confidence interval 1.26 to 7.00, p = 0.01) and pre-TAVI use of VKAs (hazard ratio 2.17, 95% confidence interval 1.12 to 4.20, p = 0.02). In conclusion, although the overall incidence of IS was small for patients with AF on edoxaban or VKA after successful TAVI, patients with a history of systemic embolic events or pre-TAVI use of VKAs may be at greater risk of IS after TAVI.

8.
EuroIntervention ; 20(14): e865-e875, 2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-39007832

RÉSUMÉ

BACKGROUND: Complete revascularisation is supported by recent trials in patients with ST-elevation myocardial infarction (STEMI) and multivessel disease (MVD) without cardiogenic shock. However, the optimal timing of non-culprit lesion revascularisation is currently debated. AIMS: This prespecified analysis of the BioVasc trial aims to determine the effect of immediate complete revascularisation (ICR) compared to staged complete revascularisation (SCR) on clinical outcomes in patients with STEMI. METHODS: Patients presenting with STEMI and MVD were randomly assigned to ICR or SCR. The primary endpoint was the composite of all-cause mortality, myocardial infarction, any unplanned ischaemia-driven revascularisation, or cerebrovascular events at 1-year post-index procedure. RESULTS: Between June 2018 and October 2021, 608 (ICR: 305, SCR: 303) STEMI patients were enrolled. No significant differences between ICR and SCR were observed at 1-year follow-up in terms of the primary endpoint (7.0% vs 8.3%, hazard ratio [HR] 0.84, 95% confidence interval [CI]: 0.47-1.50; p=0.55): all-cause mortality (2.3% vs 1.3%, HR 1.77, 95% CI: 0.52-6.04; p=0.36), myocardial infarction (1.7% vs 3.3%, HR 0.50, 95% CI: 0.17-1.47; p=0.21), unplanned ischaemia-driven revascularisation (4.1% vs 5.0%, HR 0.80, 95% CI: 0.38-1.71; p=0.57) and cerebrovascular events (1.4% vs 1.3%, HR 1.01, 95% CI: 0.25-4.03; p=0.99). At 30-day follow-up, a trend towards a reduction of the primary endpoint in the ICR group was observed (ICR: 3.0% vs SCR: 6.0%, HR 0.50, 95% CI: 0.22-1.11; p=0.09). ICR was associated with a reduction in overall hospital stay (ICR: median 3 [interquartile range {IQR} 2-5] days vs SCR: median 4 [IQR 3-6] days; p<0.001). CONCLUSIONS: Clinical outcomes at 1 year were similar for STEMI patients who had undergone ICR and those who had undergone SCR.


Sujet(s)
Maladie des artères coronaires , Intervention coronarienne percutanée , Infarctus du myocarde avec sus-décalage du segment ST , Humains , Infarctus du myocarde avec sus-décalage du segment ST/chirurgie , Infarctus du myocarde avec sus-décalage du segment ST/mortalité , Infarctus du myocarde avec sus-décalage du segment ST/thérapie , Mâle , Femelle , Adulte d'âge moyen , Intervention coronarienne percutanée/méthodes , Sujet âgé , Résultat thérapeutique , Maladie des artères coronaires/chirurgie , Maladie des artères coronaires/mortalité , Maladie des artères coronaires/imagerie diagnostique , Maladie des artères coronaires/thérapie , Facteurs temps , Délai jusqu'au traitement , Revascularisation myocardique/méthodes
9.
J Clin Med ; 13(11)2024 May 25.
Article de Anglais | MEDLINE | ID: mdl-38892807

RÉSUMÉ

Atherosclerosis is the predominant underlying etiopathology of coronary artery disease. Changes in plaque phenotype from stable to high risk may spur future major adverse cardiac events (MACE). Different pharmacological therapies have been implemented to mitigate this risk. Over the last two decades, intravascular imaging modalities have emerged in clinical studies to clarify how these therapies may affect the composition and burden of coronary plaques. Lipid-lowering agents, such as statins, ezetimibe, and proprotein convertase subtilisin/kexin type 9 inhibitors, were shown not only to reduce low-density lipoprotein levels and MACE but also to directly affect features of coronary plaque vulnerability. Studies have demonstrated that lipid-lowering therapy reduces the percentage of atheroma volume and number of macrophages and increases fibrous cap thickness. Future studies should answer the question of whether pharmacological plaque stabilization may be sufficient to mitigate the risk of MACE for selected groups of patients with atherosclerotic coronary disease.

10.
Eur J Heart Fail ; 2024 Jun 02.
Article de Anglais | MEDLINE | ID: mdl-38825743

RÉSUMÉ

AIMS: Heart failure (HF), a global pandemic affecting millions of individuals, calls for adequate predictive guidance for improved therapy. Congestion, a key factor in HF-related hospitalizations, further underscores the need for timely interventions. Proactive monitoring of intracardiac pressures, guided by pulmonary artery (PA) pressure, offers opportunities for efficient early-stage intervention, since haemodynamic congestion precedes clinical symptoms. METHODS: The BioMEMS study, a substudy of the MONITOR-HF trial, proposes a multifaceted approach integrating blood biobank data with traditional and novel HF parameters. Two additional blood samples from 340 active participants in the MONITOR-HF trial were collected at baseline, 3-, 6-, and 12-month visits and stored for the BioMEMS biobank. The main aims are to identify the relationship between temporal biomarker patterns and PA pressures derived from the CardioMEMS-HF system, and to identify the biomarker profile(s) associated with the risk of HF events and cardiovascular death. CONCLUSION: Since the prognostic value of single baseline measurements of biomarkers like N-terminal pro-B-type natriuretic peptide is limited, with the BioMEMS study we advocate a dynamic, serial approach to better capture HF progression. We will substantiate this by relating repeated biomarker measurements to PA pressures. This design rationale presents a comprehensive review on cardiac biomarkers in HF, and aims to contribute valuable insights into personalized HF therapy and patient risk assessment, advancing our ability to address the evolving nature of HF effectively.

11.
Eur Heart J Case Rep ; 8(6): ytae291, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38938469

RÉSUMÉ

Background: Left ventricular assist devices (LVADs) are increasingly utilized in cardiogenic shock and high-risk percutaneous coronary interventions (PCIs). These devices aspirate and expel blood from the left ventricle (LV) into the aorta, consequently reducing left ventricular end-diastolic pressure (LVEDP). We report a case of unexpected LVEDP rise under LV-to-aorta LVAD in the context of transcatheter aortic valve implantation (TAVI) and concomitant multi-vessel PCI. Case summary: A patient with acute heart failure, severely depressed systolic LV function, severe aortic stenosis, and multi-vessel coronary artery disease underwent TAVI and concomitant PCI under pulsatile LVAD. Notably, the patient experienced unexpected shortness of breath and elevated LVEDP while under LVAD, which normalized immediately upon LVAD removal. Discussion: Pulsatile LVAD enhances cardiac output by providing pulsatile support through a percutaneous bi-directional flow catheter. Despite expectations of reduced LVEDP and improved myocardial oxygen supply under LVAD support, we observed high LVEDP and clinical complaints of shortness of breath following TAVI and multi-vessel PCI. This case illustrates that an LVAD across the aortic valve may immobilize aortic leaflets and generate acute aortic regurgitation.

12.
Eur Heart J Digit Health ; 5(3): 379-383, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38774368

RÉSUMÉ

Aims: Invasive haemodynamic monitoring of heart failure (HF) is used to detect deterioration in an early phase thereby preventing hospitalizations. However, this invasive approach is costly and presently lacks widespread accessibility. Hence, there is a pressing need to identify an alternative non-invasive method that is reliable and more readily available. In this pilot study, we investigated the relation between wrist-derived photoplethysmography (PPG) signals and the invasively measured pulmonary capillary wedge pressure (PCWP). Methods and results: Fourteen patients with aortic valve stenosis who underwent transcatheter aortic valve replacement with concomitant right heart catheterization and PPG measurements were included. Six unique features of the PPG signals [heart rate, heart rate variability, systolic amplitude (SA), diastolic amplitude, crest time (CT), and large artery stiffness index (LASI)] were extracted. These features were used to estimate the continuous PCWP values and the categorized PCWP (low < 12 mmHg vs. high ≥ 12 mmHg). All PPG features resulted in regression models that showed low correlations with the invasively measured PCWP. Classification models resulted in higher performances: the model based on the SA and the model based on the LASI both resulted in an area under the curve (AUC) of 0.86 and the model based on the CT resulted in an AUC of 0.72. Conclusion: These results demonstrate the capability to non-invasively classify patients into clinically meaningful categories of PCWP using PPG signals from a wrist-worn wearable device. To enhance and fully explore its potential, the relationship between PPG and PCWP should be further investigated in a larger cohort of HF patients.

13.
ASAIO J ; 2024 May 20.
Article de Anglais | MEDLINE | ID: mdl-38776488

RÉSUMÉ

Patients undergoing veno-arterial extracorporeal membrane oxygenation (VA-ECMO) typically suffer from cardiogenic pulmonary edema and lung atelectasis, which can exacerbate right ventricular (RV) dysfunction through an increase in lung elastance and RV afterload. Invasive mechanical ventilation settings, and positive end-expiratory pressure (PEEP) in particular, can help to improve RV performance by optimizing lung recruitment and minimizing alveolar overdistention. In this report, we present a VA-ECMO supported patient in whom in vivo RV pressure-volume (PV) loops were measured during a decremental PEEP trial, leading to the identification of an optimum PEEP level from a cardio-respiratory viewpoint. This innovative approach of tailoring mechanical ventilation settings according to cardio-respiratory physiology through in vivo RV PV loops may provide a novel way to optimize hemodynamics and patient outcomes.

14.
EuroIntervention ; 20(9): 536-550, 2024 May 10.
Article de Anglais | MEDLINE | ID: mdl-38726720

RÉSUMÉ

The identification and management of patients at high bleeding risk (HBR) undergoing transcatheter aortic valve implantation (TAVI) are of major importance, but the lack of standardised definitions is challenging for trial design, data interpretation, and clinical decision-making. The Valve Academic Research Consortium for High Bleeding Risk (VARC-HBR) is a collaboration among leading research organisations, regulatory authorities, and physician-scientists from Europe, the USA, and Asia, with a major focus on TAVI-related bleeding. VARC-HBR is an initiative of the CERC (Cardiovascular European Research Center), aiming to develop a consensus definition of TAVI patients at HBR, based on a systematic review of the available evidence, to provide consistency for future clinical trials, clinical decision-making, and regulatory review. This document represents the first pragmatic approach to a consistent definition of HBR evaluating the safety and effectiveness of procedures, devices and drug regimens for patients undergoing TAVI..


Sujet(s)
Consensus , Hémorragie , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/effets indésirables , Facteurs de risque , Hémorragie/étiologie , Appréciation des risques , Sténose aortique/chirurgie , Valve aortique/chirurgie
15.
Am J Cardiol ; 223: 73-80, 2024 07 15.
Article de Anglais | MEDLINE | ID: mdl-38777210

RÉSUMÉ

Recent trials suggested immediate complete revascularization (ICR) as a safe alternative to staged complete revascularization (SCR), but the impact of the respective percutaneous coronary intervention strategies between on- versus off-hours is unclear. On-hours was defined as an index revascularization performed between 8:00 a.m. and 6:00 p.m., Monday to Friday, or else the procedure was defined as performed during off-hours. The primary end point consisted of a composite of all-cause mortality, myocardial infarction, unplanned ischemia-driven revascularization, and cerebrovascular events at 1-year follow-up. We used Cox regression models to relate randomized treatment with study end points. We evaluated multiplicative and additive interactions between on- versus off-hours and randomized treatment. The BIOVASC (Percutaneous Complete Revascularization Strategies Using Sirolimus Eluting Biodegradable Polymer Coated Stents in Patients Presenting With Acute Coronary Syndromes and Multivessel Disease) trial enrolled 1,097 and 428 patients during on- and off-hours, respectively. Patients randomized during off-hours were more likely to present with ST-segment elevation myocardial infarction (66.4% vs 29.5%, p <0.001). The composite primary outcome occurred in 8.4% and 10.1% of patients randomized to ICR and SCR, respectively, during on-hours (hazard ratio 0.80, 95% confidence interval 0.54 to 1.19). During off-hours, the primary composite outcome occurred in 5.4% and 7.7% in ICR and SCR (0.69, 95% confidence interval 0.32 to 1.46) with no evidence of a differential effect (interaction pmultiplicative = 0.70, padditive = 0.56). No differential effect was found between treatment allocation and on- versus off-hours in any of the secondary outcomes. In conclusion, no differential treatment effect was found when comparing ICR versus SCR in patients presenting with acute coronary syndrome and multivessel disease during on- or off-hours.


Sujet(s)
Endoprothèses à élution de substances , Intervention coronarienne percutanée , Humains , Mâle , Femelle , Intervention coronarienne percutanée/méthodes , Adulte d'âge moyen , Sujet âgé , Facteurs temps , Syndrome coronarien aigu/chirurgie , Syndrome coronarien aigu/thérapie , Infarctus du myocarde avec sus-décalage du segment ST/chirurgie , Infarctus du myocarde avec sus-décalage du segment ST/thérapie , Revascularisation myocardique/méthodes , Revascularisation myocardique/statistiques et données numériques , Maladie des artères coronaires/chirurgie , Résultat thérapeutique , Sirolimus/usage thérapeutique , Études de suivi
16.
JACC Cardiovasc Imaging ; 17(8): 847-860, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38795109

RÉSUMÉ

BACKGROUND: In patients with low-gradient aortic stenosis (AS) and low transvalvular flow, dobutamine stress echocardiography (DSE) is recommended to determine AS severity, whereas the degree of aortic valve calcification (AVC) supposedly correlates with AS severity according to current European and American guidelines. OBJECTIVES: The purpose of this study was to assess the relationship between AVC and AS severity as determined using echocardiography and DSE in patients with aortic valve area <1 cm2 and peak aortic valve velocity <4.0 m/s. METHODS: All patients underwent DSE to determine AS severity and multislice computed tomography to quantify AVC. Receiver-operating characteristics curve analysis was used to assess the diagnostic value of AVC for AS severity grading as determined using echocardiography and DSE in men and women. RESULTS: A total of 214 patients were included. Median age was 78 years (25th-75th percentile: 71-84 years) and 25% were women. Left ventricular ejection fraction was reduced (<50%) in 197 (92.1%) patients. Severe AS was diagnosed in 106 patients (49.5%). Moderate AS was diagnosed in 108 patients (50.5%; in 77 based on resting transthoracic echocardiography, in 31 confirmed using DSE). AVC score was high (≥2,000 for men or ≥1,200 for women) in 47 (44.3%) patients with severe AS and in 47 (43.5%) patients with moderate AS. AVC sensitivity was 44.3%, specificity was 56.5%, and positive and negative predictive values for severe AS were 50.0% and 50.8%, respectively. Area under the receiver-operating characteristics curve was 0.508 for men and 0.524 for women. CONCLUSIONS: Multi-slice computed tomography-derived AVC scores showed poor discrimination between grades of AS severity using DSE and cannot replace DSE in the diagnostic work-up of low-gradient severe AS.


Sujet(s)
Sténose aortique , Valve aortique , Calcinose , Échocardiographie de stress , Tomodensitométrie multidétecteurs , Valeur prédictive des tests , Indice de gravité de la maladie , Humains , Sténose aortique/imagerie diagnostique , Sténose aortique/physiopathologie , Femelle , Mâle , Sujet âgé , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Valve aortique/anatomopathologie , Calcinose/imagerie diagnostique , Calcinose/physiopathologie , Sujet âgé de 80 ans ou plus , Reproductibilité des résultats , Courbe ROC , Fonction ventriculaire gauche , Aire sous la courbe , Débit systolique , Hémodynamique
17.
Clin Res Cardiol ; 2024 Apr 15.
Article de Anglais | MEDLINE | ID: mdl-38619575

RÉSUMÉ

BACKGROUND: Transcatheter aortic valve implantation (TAVI) serves a growing range of patients with severe aortic stenosis (AS). TAVI has evolved to a streamlined procedure minimizing length of hospital stay. AIMS: To evaluate the safety and efficacy of an early discharge (ED) strategy after TAVI. METHODS: We performed an international, multi-center, prospective observational single-arm study in AS patients undergoing TAVI with the ACURATE valve platform. Eligibility for ED was assessed prior to TAVI and based on prespecified selection criteria. Discharge ≤ 48 h was defined as ED. Primary Valve Academic Research Consortium (VARC)-3-defined 30-day safety and efficacy composite endpoints were landmarked at 48 h and compared between ED and non-ED groups. RESULTS: A total of 252 patients were included. The median age was 82 [25th-75th percentile, 78-85] years and the median Society of Thoracic Surgeons Predicted Risk of Mortality (STS-PROM) score was 2.2% [25th-75th percentile, 1.6-3.3]. ED and non-ED were achieved in 173 (69%) and 79 (31%) patients respectively. Monitoring for conduction disturbances was the principal reason for non-ED (33%). Overall, at 30 days, all-cause mortality was 1%, new permanent pacemaker rate was 4%, and valve- or procedure-related rehospitalization was 4%. There was no difference in the primary safety and efficacy endpoint between the ED and non-ED cohorts (OR 0.84 [25th-75th percentile, 0.31-2.26], p = 0.73, and OR 0.97 [25th-75th percentile, 0.46-2.06], p = 0.94). The need for rehospitalization was similarly low for ED and non-ED groups. CONCLUSION: Early discharge after TAVI with the ACURATE valve is safe and feasible in selected patients. Rhythm monitoring and extended clinical observation protracted hospital stay.

18.
JACC Cardiovasc Interv ; 17(8): 979-988, 2024 Apr 22.
Article de Anglais | MEDLINE | ID: mdl-38658126

RÉSUMÉ

BACKGROUND: Symptomatic patients with severe aortic stenosis (AS) at high risk for surgical aortic valve replacement (SAVR) sustain comparable improvements in health status over 5 years after transcatheter aortic valve replacement (TAVR) or SAVR. Whether a similar long-term benefit is observed among intermediate-risk AS patients is unknown. OBJECTIVES: The purpose of this study was to assess health status outcomes through 5 years in intermediate risk patients treated with a self-expanding TAVR prosthesis or SAVR using data from the SURTAVI (Surgical Replacement and Transcatheter Aortic Valve Implantation) trial. METHODS: Intermediate-risk patients randomized to transfemoral TAVR or SAVR in the SURTAVI trial had disease-specific health status assessed at baseline, 30 days, and annually to 5 years using the Kansas City Cardiomyopathy Questionnaire (KCCQ). Health status was compared between groups using fixed effects repeated measures modelling. RESULTS: Of the 1,584 patients (TAVR, n = 805; SAVR, n = 779) included in the analysis, health status improved more rapidly after TAVR compared with SAVR. However, by 1 year, both groups experienced large health status benefits (mean change in KCCQ-Overall Summary Score (KCCQ-OS) from baseline: TAVR: 20.5 ± 22.4; SAVR: 20.5 ± 22.2). This benefit was sustained, albeit modestly attenuated, at 5 years (mean change in KCCQ-OS from baseline: TAVR: 15.4 ± 25.1; SAVR: 14.3 ± 24.2). There were no significant differences in health status between the cohorts at 1 year or beyond. Similar findings were observed in the KCCQ subscales, although a substantial attenuation of benefit was noted in the physical limitation subscale over time in both groups. CONCLUSIONS: In intermediate-risk AS patients, both transfemoral TAVR and SAVR resulted in comparable and durable health status benefits to 5 years. Further research is necessary to elucidate the mechanisms for the small decline in health status noted at 5 years compared with 1 year in both groups. (Safety and Efficacy Study of the Medtronic CoreValve® System in the Treatment of Severe, Symptomatic Aortic Stenosis in Intermediate Risk Subjects Who Need Aortic Valve Replacement [SURTAVI]; NCT01586910).


Sujet(s)
Sténose aortique , Valve aortique , Artère fémorale , État de santé , Prothèse valvulaire cardiaque , Qualité de vie , Récupération fonctionnelle , Indice de gravité de la maladie , Remplacement valvulaire aortique par cathéter , Humains , Sténose aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/physiopathologie , Femelle , Mâle , Facteurs temps , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/instrumentation , Résultat thérapeutique , Sujet âgé , Sujet âgé de 80 ans ou plus , Facteurs de risque , Valve aortique/chirurgie , Valve aortique/physiopathologie , Valve aortique/imagerie diagnostique , Appréciation des risques , Implantation de valve prothétique cardiaque/instrumentation , Implantation de valve prothétique cardiaque/effets indésirables , Cathétérisme périphérique/effets indésirables , Ponctions , Conception de prothèse
19.
JACC Cardiovasc Interv ; 17(8): 1007-1016, 2024 Apr 22.
Article de Anglais | MEDLINE | ID: mdl-38573257

RÉSUMÉ

BACKGROUND: Data on valve reintervention after transcatheter aortic valve replacement (TAVR) or surgical aortic valve replacement (SAVR) are limited. OBJECTIVES: The authors compared the 5-year incidence of valve reintervention after self-expanding CoreValve/Evolut TAVR vs SAVR. METHODS: Pooled data from CoreValve and Evolut R/PRO (Medtronic) randomized trials and single-arm studies encompassed 5,925 TAVR (4,478 CoreValve and 1,447 Evolut R/PRO) and 1,832 SAVR patients. Reinterventions were categorized by indication, timing, and treatment. The cumulative incidence of reintervention was compared between TAVR vs SAVR, Evolut vs CoreValve, and Evolut vs SAVR. RESULTS: There were 99 reinterventions (80 TAVR and 19 SAVR). The cumulative incidence of reintervention through 5 years was higher with TAVR vs SAVR (2.2% vs 1.5%; P = 0.017), with differences observed early (≤1 year; adjusted subdistribution HR: 3.50; 95% CI: 1.53-8.02) but not from >1 to 5 years (adjusted subdistribution HR: 1.05; 95% CI: 0.48-2.28). The most common reason for reintervention was paravalvular regurgitation after TAVR and endocarditis after SAVR. Evolut had a significantly lower incidence of reintervention than CoreValve (0.9% vs 1.6%; P = 0.006) at 5 years with differences observed early (adjusted subdistribution HR: 0.30; 95% CI: 0.12-0.73) but not from >1 to 5 years (adjusted subdistribution HR: 0.61; 95% CI: 0.21-1.74). The 5-year incidence of reintervention was similar for Evolut vs SAVR (0.9% vs 1.5%; P = 0.41). CONCLUSIONS: A low incidence of reintervention was observed for CoreValve/Evolut R/PRO and SAVR through 5 years. Reintervention occurred most often at ≤1 year for TAVR and >1 year for SAVR. Most early reinterventions were with the first-generation CoreValve and managed percutaneously. Reinterventions were more common following CoreValve TAVR compared with Evolut TAVR or SAVR.


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Complications postopératoires , Remplacement valvulaire aortique par cathéter , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Sténose aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/physiopathologie , Prothèse valvulaire cardiaque , Implantation de valve prothétique cardiaque/effets indésirables , Implantation de valve prothétique cardiaque/instrumentation , Complications postopératoires/chirurgie , Conception de prothèse , Essais contrôlés randomisés comme sujet , Appréciation des risques , Facteurs de risque , Indice de gravité de la maladie , Facteurs temps , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/instrumentation , Résultat thérapeutique , Incidence , Reprise du traitement
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE