Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Anal Chim Acta ; 1284: 342006, 2023 Dec 15.
Article de Anglais | MEDLINE | ID: mdl-37996161

RÉSUMÉ

Development of high-precision human epidermal growth factor receptor 2 (HER2) assay is essential for the early diagnostic and prevention of breast cancer. In this work, an innovative Fe/Mn bimetallic nanozyme at the edge of N-doped carbon defects (FeMn-NCedge) with abundant active sites was prepared through the hydrothermal synthetic method. FeMn-NCedge nanozyme displayed excellent peroxidase-like activity relative to the H2O2-catalyzed 3,3',5,5'-tetramethylbenzidine (TMB) system for generation of the oxidized TMB (oxTMB). As a proof-of-concept application, we constructed an electrochemical immunoassay for the detection of HER2 based on the unique merits of FeMn-NCedge. Initially, a sandwiched immunoreaction was carried out in the microtiter plate coated with monoclonal anti-HER2 capture antibodies using glucose oxidase (GOx)-labeled anti-HER2 as detection antibody. The carried GOx could catalyze glucose to produce H2O2, thus resulting in the formation of oxTMB with the assistance of TMB and FeMn-NCedge nanozyme. The produced oxTMB could be determined on the electrode by the chronoamperometry at an applied potential of +10 mV. Experimental results revealed that the steady-state current increased with the increasing HER2 concentration in the sample, and gave a good linear relationship within the dynamic range of 0.01-10 ng/mL at a limit of detection of 5.4 pg/mL HER2. In addition, good reproducibility, high specificity and acceptable accuracy were acquired for the measurement of human serum samples. Importantly, this method can be extended for quantitative monitoring other disease-related proteins by changing the corresponding antibodies.


Sujet(s)
Carbone , Peroxyde d'hydrogène , Humains , Carbone/composition chimique , Peroxyde d'hydrogène/composition chimique , Reproductibilité des résultats , Domaine catalytique , Dosage immunologique/méthodes , Glucose oxidase/composition chimique , Or/composition chimique , Colorimétrie/méthodes , Limite de détection
2.
Anal Chem ; 95(38): 14494-14501, 2023 09 26.
Article de Anglais | MEDLINE | ID: mdl-37707360

RÉSUMÉ

Noble-metal nanozymes have demonstrated great potential in various fields. However, aggregation of single-particle nanoparticles severely affects their exposed catalytically active sites to the extent of exhibiting weak enzyme-like activity. Here, we present an organic block surfactant (polyvinylpyrrolidone, PVP) to construct monodisperse water-stable Pt nanoclusters (Pt NCs) for an enhanced immunoassay of cardiac troponin I (cTnI). The PVP-modified Pt NC nanozyme exhibited up to 16.3 U mg-1 peroxidase-mimicking activity, which was mainly attributed to the ligand modification on the surface and the electron-absorbing effect of the ligand on the Pt NCs. The PVP-modified Pt NCs have a lower OH-transition potential, as determined by density functional theory. Under optimized experimental conditions, the enhanced nanozyme immunoassay strategy exhibited an ultrawide dynamic response range of 0.005-50 ng mL-1 for cTnI targets with a detection limit of 1.3 pg mL-1, far superior to some reported test protocols. This work provides a designable pathway for the design of artificial enzymes with high enzyme-like activity to further expand the practical range of enzyme alternatives.


Sujet(s)
Polymères , Troponine I , Ligands , Povidone , Dosage immunologique
3.
PLoS One ; 18(3): e0283205, 2023.
Article de Anglais | MEDLINE | ID: mdl-36930608

RÉSUMÉ

The problem of high stress conditions is a critical challenge for mining activity in deep metal mines, and the difficulty and economic cost of maintaining stope stability also increases. In order to ensure stope stability in the mining process, it is necessary to evaluate stope stability for a more stable stope structure. However, there are many kinds of methods for rock stability assessment, and most of them are based on empirical and analytical methods, which lead to uncertain results. In this paper, a comprehensive evaluation method including factors of stope stability, self-stabilization time, maximum safety span, and support measure is determined, which is more likely to provide a comprehensive result. Finally, it was verified by the field application in Jiaojia Gold Mine. Results show that it can accurately evaluate the stope stability from different aspects compared with the traditional single evaluation method, and it leads to a more comprehensive and reliable result.


Sujet(s)
Or , Mine
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...