Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 3 de 3
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Vet Surg ; 2024 Jul 25.
Article de Anglais | MEDLINE | ID: mdl-39051377

RÉSUMÉ

OBJECTIVE: The aim of this study was to describe a technique for anastomosis of the thoracic duct (TD) to the azygos vein (AV) using a microvascular anastomotic coupler (MAC) device in feline cadavers. Our hypothesis was that a TD-AV lymphaticovenous anastomosis would be feasible in feline cadavers. STUDY DESIGN: Cadaveric study. ANIMALS: Eight domestic shorthair feline cadavers. METHODS: A left paracostal laparotomy and 9th or 10th intercostal thoracotomy was performed. Contrast media was injected into a mesenteric lymph node and lymphography was used to identify the TD and its branches. The TD and AV were isolated, ligated, and divided with the aid of a surgical microscope. The TD and AV were anastomosed end-to-end using a 1.5 or 2.0 mm MAC. Intraoperative patency was assessed by manipulation of chyle and venous blood across the anastomosis. Mesenteric lymphography was repeated to confirm postoperative anastomotic patency. RESULTS: The TD was identified via lymphography in seven of eight cats. The anastomosis was successful and patency was confirmed via intraoperative assessment and postoperative lymphography in all cats. The median (range) duration for the dissection and anastomosis portions of the procedure was 122 (80-150) min. CONCLUSION: End-to-end anastomosis of the TD to the AV using a MAC was feasible in the feline cadaver without major intraoperative technical challenges. CLINICAL SIGNIFICANCE: Anastomosis of the TD and AV may have application as an alternative treatment for idiopathic chylothorax in cats. By directly connecting the abdominal lymphatics to the central venous system, the stimulus for collateral vessel development around the site of TD ligation may be minimized, which may prevent leakage of chyle through the more cranial lymphatics.

2.
Trials ; 25(1): 312, 2024 May 09.
Article de Anglais | MEDLINE | ID: mdl-38725072

RÉSUMÉ

BACKGROUND: Clinical trials often involve some form of interim monitoring to determine futility before planned trial completion. While many options for interim monitoring exist (e.g., alpha-spending, conditional power), nonparametric based interim monitoring methods are also needed to account for more complex trial designs and analyses. The upstrap is one recently proposed nonparametric method that may be applied for interim monitoring. METHODS: Upstrapping is motivated by the case resampling bootstrap and involves repeatedly sampling with replacement from the interim data to simulate thousands of fully enrolled trials. The p-value is calculated for each upstrapped trial and the proportion of upstrapped trials for which the p-value criteria are met is compared with a pre-specified decision threshold. To evaluate the potential utility for upstrapping as a form of interim futility monitoring, we conducted a simulation study considering different sample sizes with several different proposed calibration strategies for the upstrap. We first compared trial rejection rates across a selection of threshold combinations to validate the upstrapping method. Then, we applied upstrapping methods to simulated clinical trial data, directly comparing their performance with more traditional alpha-spending and conditional power interim monitoring methods for futility. RESULTS: The method validation demonstrated that upstrapping is much more likely to find evidence of futility in the null scenario than the alternative across a variety of simulations settings. Our three proposed approaches for calibration of the upstrap had different strengths depending on the stopping rules used. Compared to O'Brien-Fleming group sequential methods, upstrapped approaches had type I error rates that differed by at most 1.7% and expected sample size was 2-22% lower in the null scenario, while in the alternative scenario power fluctuated between 15.7% lower and 0.2% higher and expected sample size was 0-15% lower. CONCLUSIONS: In this proof-of-concept simulation study, we evaluated the potential for upstrapping as a resampling-based method for futility monitoring in clinical trials. The trade-offs in expected sample size, power, and type I error rate control indicate that the upstrap can be calibrated to implement futility monitoring with varying degrees of aggressiveness and that performance similarities can be identified relative to considered alpha-spending and conditional power futility monitoring methods.


Sujet(s)
Essais cliniques comme sujet , Simulation numérique , Inutilité médicale , Plan de recherche , Humains , Essais cliniques comme sujet/méthodes , Taille de l'échantillon , Interprétation statistique de données , Modèles statistiques , Résultat thérapeutique
3.
Vet Anaesth Analg ; 46(4): 529-537, 2019 Jul.
Article de Anglais | MEDLINE | ID: mdl-31147260

RÉSUMÉ

OBJECTIVE: To compare the antinociceptive, sedative and cardiovascular effects of dexmedetomidine pharmacopuncture at Governing Vessel 1 (GV 1) with dexmedetomidine intramuscular (IM) administration. STUDY DESIGN: Randomized, masked crossover design. ANIMALS: A group of eight healthy female cats. METHODS: Cats were randomly administered either dexmedetomidine (0.005 mg kg-1; Dex-IM) IM or at acupuncture point GV 1 (Dex-P) separated by 1 week. Prior to and up to 120 minutes posttreatment, skin temperature (ST), thermal threshold (TT), heart rate (HR), respiratory rate (fR), sedation, muscle relaxation and auditory response scores were recorded. Parametric data were analyzed using a two-way repeated measures anova followed by Tukey's test for multiple comparisons. Nonparametric data were analyzed using a Friedman test followed by Dunn's multiple comparisons test, and Wilcoxon signed-rank test with Bonferroni correction for multiple comparisons. Significance was set at p ≤ 0.05. RESULTS: There were no differences within or between treatments for ST, fR and auditory response. TT was significantly higher at 30-90 minutes in Dex-P (p ≤ 0.0285) than baseline. TT was significantly higher at 60-90 minutes for Dex-P than for Dex-IM (p ≤ 0.0252). HR was significantly lower at 10-75 minutes in Dex-P (p ≤ 0.0378) and at 5-75 minutes in Dex-IM (p ≤ 0.0132) than baseline. Compared with baseline, sedation scores were higher at 25 minutes (p = 0.0327) and 30 minutes (p = 0.0327), and muscle relaxation scores were higher at 25 minutes (p = 0.0151) and 35 minutes (p = 0.0151) in Dex-P. There were no differences in HR, sedation and muscle relaxation scores between treatments. CONCLUSIONS AND CLINICAL RELEVANCE: Dex-P increased thermal antinociception compared with Dex-IM at the same dose of dexmedetomidine in cats. This antinociceptive effect must be evaluated under clinical situations.


Sujet(s)
Analgésie par acupuncture/médecine vétérinaire , Chats , Sédation consciente/médecine vétérinaire , Dexmédétomidine/administration et posologie , Rythme cardiaque/effets des médicaments et des substances chimiques , Douleur/médecine vétérinaire , Animaux , Études croisées , Dexmédétomidine/pharmacologie , Femelle , Température élevée , Relâchement musculaire/effets des médicaments et des substances chimiques , Répartition aléatoire , Respiration/effets des médicaments et des substances chimiques , Température cutanée/effets des médicaments et des substances chimiques
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE