Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 10 de 10
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Oral Dis ; 2024 Jul 28.
Article de Anglais | MEDLINE | ID: mdl-39073178

RÉSUMÉ

OBJECTIVE: To evaluate the efficacy of recombinant psoriasin as a novel treatment for oral candidiasis by eliminating Candida albicans growth on polymethyl methacrylate denture base. MATERIALS AND METHODS: Recombinant psoriasin protein was expressed and purified from E. coli, and Candida growth was monitored in vitro with varying concentrations of psoriasin. Subsequently, denture-base polymethyl methacrylate was immersed in psoriasin's solution or voriconazole, and fungal growth on the acrylic base and in the medium was examined by scanning electron microscopy and optical density, respectively. Cellular viability of HeLa and human gingival fibroblast cells treated with psoriasin was measured by methylene blue assay. RESULTS: The findings reveal an effective antifungal activity of psoriasin, completely inhibiting Candida albicans growth in RPMI at a protein concentration above 400 nM. Immersing the polymethyl methacrylate with 50 µM psoriasin completely eradicates fungal growth. Psoriasin has low cytotoxicity in HeLa cells at a concentration higher than 12 µM and no toxic effect on human gingival fibroblasts. CONCLUSIONS: This study marks psoriasin as an effective alternative to conventional antifungal treatments for denture stomatitis and a safe alternative to chemical antifungals in dental medicine and beyond.

2.
J Clin Med ; 13(11)2024 Jun 05.
Article de Anglais | MEDLINE | ID: mdl-38893040

RÉSUMÉ

Background: In everyday dentistry, monolithic single crowns can be cemented with self-adhesive resin cements. The aim of this in vitro study was to evaluate how the marginal adaptation of full monolithic zirconia-reinforced lithium silicate (ZLS) single crowns is influenced by three different self-adhesive resin cements. Methods: Forty-five typodont teeth fully prepared for full monolithic crowns were divided into three groups (fifteen each) for the use of three different self-adhesive resin cements. A fourth control group (Temp-bond) was created by taking five teeth from each group before cementation with self-adhesive resin cements. All forty-five abutments were scanned using a Primescan intra-oral scanner (IOS), followed by computer-aided design (CAD) and computer-aided manufacturing (CAM) of zirconia-reinforced lithium silicate (ZLS) full crowns using a four-axis machine. Initially, the crowns of the control group were fixed to the abutments using Temp-bond, and the marginal gap was evaluated using a scanning electron microscope (SEM). After removing the control group crowns from the abutments, fifteen crowns in each group were cemented using a different self-adhesive resin cement and observed under SEM for evaluation of the marginal gap. A Kolmogorov-Smirnov test was performed, indicating no normal distribution (p < 0.05), followed by Mann-Whitney tests (α = 0.05). Results: The total mean marginal gap of the temp-bond control group was significantly lower compared to all three groups of self-adhesive resin cement (p < 0.0005). The total mean marginal gap of the G-cem ONE group was significantly lower compared to the TheraCem group (p < 0.026) and RelyX U200 group (p < 0.008). The total mean marginal gap of the TheraCem group was significantly higher than the G-cem ONE group (p < 0.026) but showed no significant difference with the RelyX U200 group (p > 0.110). Conclusions: All four groups showed a clinically acceptable marginal gap (<120 microns). Although all three groups of self-adhesive resin cement showed a significant increase in the marginal gap compared to the temp-bond control group, they were within the limits of clinical acceptability. Regarding the marginal gap, in everyday dentistry, it is acceptable to use all three self-adhesive resin cements, although the G-cem ONE group exhibited the lowest marginal gap for ZLS single crowns.

3.
J Funct Biomater ; 15(5)2024 May 15.
Article de Anglais | MEDLINE | ID: mdl-38786641

RÉSUMÉ

This study aimed to compare the impact of CAD/CAM closed systems and open systems on the marginal gap of monolithic zirconia-reinforced lithium silicate (ZLS) ceramic crowns, as both systems are used in everyday dentistry, both chair-side and laboratory. For the closed system, 20 plastic teeth were scanned by a Primescan intra-oral scanner (IOS), and for the open system, the same number of plastic teeth were scanned by Trios 4 IOS. For the closed system, CEREC software was used, and for the open system, EXOCAD software was used. All 40 ZLS crowns were grinded by the same four-axis machine and cemented with Temp-bond, followed by self-adhesive resin cement. For each type of cement, an evaluation of the marginal gap was conducted by scanning electron microscopy (SEM). Before comparisons between the groups, a Kolmogorov-Smirnov test was performed on the study variables showing a normal distribution (p > 0.05). Independent T tests (α = 0.05) and paired-sample T tests (α = 0.05) were used. The independent T test found no significant mean marginal gap differences in the zirconia-reinforced lithium silicate crowns bonded with Temp-bond and scanned by Primescan (28.09 µm ± 3.06) compared to Trios 4 (28.94 µm ± 3.30) (p = 0.401), and there was no significant mean marginal gap differences in zirconia-reinforced lithium silicate crowns bonded with self-adhesive resin cement (Gcem ONE) and scanned by Primescan (46.70 µm ± 3.80) compared to Trios 4 (47.79 µm ± 2.59) (p = 0.295). Paired-sample T tests showed significantly higher mean marginal gaps with Gcem ONE compared to Temp-bond for the total mean marginal gap when scanning with Primescan (p = 0.0005) or Trios 4 (p = 0.0005). In everyday dentistry, both closed systems (Primescan with Cerec) and open systems (Trios 4 with Exocad) can be used to achieve an acceptable (<120 µm) marginal gap for ZLS CELTRA® DUO single crowns. There is a significant difference between cementation with Temp-bond and Gcem ONE self-adhesive resin cement (p < 0.05).

4.
J Clin Med ; 13(8)2024 Apr 18.
Article de Anglais | MEDLINE | ID: mdl-38673631

RÉSUMÉ

Background: In this study, we aimed to compare the effects of conventional and digital impressions on several parameters (inter-implant distance, intra-implant distance, inter-implant axis, and intra-implant axis) of three implants in curved lines and straight lines by using a laboratory scanner (LBS) versus an intra-oral scanner (IOS). Methods: Two 3D models were fabricated using a printer, each model with three internal hex implants analogues at the positions of 15#,16#,17# (straight line) and 12#,13#,14# (curved line). Standard intra-oral scan bodies (ISBs) were used, and the two models were scanned using 7 Series dental wings (LBS, reference model), followed by ten scans with Primescan (digital method). Standard Tessellation Language (STL) files were created. Five polyether impressions were taken from each model (straight and curved), and gypsum type 4 models were poured; each model was scanned five times to create a total of 25 STL files for each group (conventional method). The comparison between all the STL files (conventional and digital) was made by superimposition of the STL files on the STL reference model laboratory file using a 3D analyzing software. A Kolmogorov-Smirnov test was performed, followed by Mann-Whitney tests and Wilcoxon signed-rank tests. (p < 0.05). Results: For the conventional method, the mean errors were significantly higher for the curved line model (12-14) compared to the straight line model (15-17) for most parameters (p < 0.05). For the digital method, the mean errors were significantly higher for the curved-line model (12-14) compared to the straight line model (15-17) in half of the parameters (p < 0.05). Within the curved line model (12-14) and the straight line model (15-17), the mean errors between the conventional method and the digital method were not significant for most variables. Conclusions: The difference between curved lines and straight lines has an impact on the mean error of the conventional method. Both methods are reliable for straight and curved lines in partially dentate situations.

5.
J Funct Biomater ; 15(2)2024 Feb 18.
Article de Anglais | MEDLINE | ID: mdl-38391900

RÉSUMÉ

The configuration of implant-supported prostheses is considered to influence the magnitude of stress concentrations, affecting their survival rate. The purpose of this study is to determine, through strain gauge measurements during load application, the dispersion and magnitude of strain concentrations in different implant-supported prosthesis designs. All designs matched those commonly used in posterior partially edentulous states. Three implants were inserted into an epoxy resin model (PLM-4B Vishay Measurements Group Inc., Raleigh, NC, USA), allowing for the delivery of three- and four-unit crowns in different cemented configurations. Loads were applied at vertical and oblique directions over the cast crowns in six different configurations representing various posterior partially edentulous restorations. The readings from the strain gauges adhered to the implant necks' presented data on implant strain. Prostheses including cantilevers showed the highest strain among the three-unit prostheses within the prosthetic complex, and three single units showed the least (8133 µs vs. 201 µs, respectively). Angulated load application also had a role in amplifying the strains recorded, resulting in total strains of between 3.5 and 20 times higher than during vertical loading in all configurations. It can be concluded that the configuration of implant-fixed partial prosthesis changes the loads engaging the restoration, the implant, and, probably, the supporting bone.

6.
Article de Anglais | MEDLINE | ID: mdl-36661882

RÉSUMÉ

A failed implant site is prone to reduced alveolar bone volume, both horizontally and vertically. The present study assessed the outcome of using cancellous bone block allografts for ridge reconstruction following the removal of failed implants associated with severe bone loss. Individuals presenting with failed implants and massive bone loss were included. Cancellous bone block allografts were used for reconstruction of the atrophic alveolar ridge. Radiographic evaluation at 6 months postgrafting revealed favorable bone healing, allowing implant placement. Bone biopsy samples were taken during implant placement. Twenty-four blocks and 58 implants were placed in 16 patients. Over a mean follow-up time of 40 ± 15 months, the mean bone gain was 5 ± 0.5 mm horizontally and 7 ± 0.5 mm vertically. Block and implant survival rates were 96% (1 block failed) and 95% (3 implants failed), respectively. Histomorphometrically, the mean percentage of newly formed bone was 40%, with 20% residual cancellous block allograft and 40% marrow and connective tissue. Cancellous bone block allograft is a viable treatment alternative for reconstructing the alveolar ridge to achieve a successful second reimplantation, even in the presence of initial severe bone loss.


Sujet(s)
Reconstruction de crête alvéolaire , Implants dentaires , Humains , Pose d'implant dentaire endo-osseux , Études prospectives , Transplantation homologue , Processus alvéolaire/anatomopathologie , Allogreffes , Transplantation osseuse , Résultat thérapeutique
7.
J Clin Med ; 11(12)2022 Jun 19.
Article de Anglais | MEDLINE | ID: mdl-35743594

RÉSUMÉ

BACKGROUND: Substantial effort is dedicated to finding the most favorable parameters that will ensure low aftercare demands among edentulous patients wearing mandibular implant supported overdentures (MISODs). The purpose of this retrospective cohort study was to compare prosthetic aftercare between MISOD patients with a simultaneous (group A) vs. a three-week settling in period (group B) prior to attachment incorporation. METHODS: Forty-five patients enrolled in this study. Two implants per patient were placed using a two-stage implant insertion protocol. Second-stage surgery was performed after three months. All patients received ball attachments using the direct (chairside) incorporation method. Twenty-two patients received their dentures with simultaneous attachment activation and the rest-twenty-three patients-after a three-week settling in period. Patients' files were scanned for aftercare visits. Outcome parameters included sore spot relief, attachment incorporation, and denture repair. Additionally, gingival index measurements were compared. Confounding factors included age, gender, and implant dimensions. RESULTS: The mean follow-up for the entire cohort was 84 ± 21 months, and the range 39-120 months. The mean number of visits for group A vs. B respectively: pressure sores relieve (3.63 ± 0.84 vs. 3.71 ± 0.61, p = 0.581), liner exchange due to loss of retention (2.09 ± 1.03 vs. 2.31 ± 1.04 p = 0.487), and gingival index (1.3 ± 0.3 vs. 1.03 ± 0.2, p = 0.653) exhibited no statistically significant differences between the tested groups. No statistically significant differences between the groups were also noted for the denture repair aftercare treatments (p = 0.318) and the independent variables including age, gender, and implant length. CONCLUSIONS: Prosthetic aftercare in MISOD wearers is similar whether a simultaneous or a three-week settling in period for attachment incorporation is applied.

8.
J Clin Med ; 10(20)2021 Oct 09.
Article de Anglais | MEDLINE | ID: mdl-34682757

RÉSUMÉ

BACKGROUND: Various conditions may lead to bony deficiency in the anterior maxilla. The present study evaluated esthetic (PES-pink esthetic score and WES-white esthetic score) results after augmentation of the anterior atrophic maxilla using cancellous bone-block allograft followed by implant placement and late (conventional) loading. METHODS: Cohort study that included 33 patients with missing teeth in the upper anterior region characterized by extensive bone loss. Allogeneic cancellous bone-blocks were used for augmentation. Six months later, a dental implant was inserted. After a waiting time of an additional six-months, implant exposure and reconstruction were performed. The mean follow-up period was 62.93 ± 17.37 months (range 19-82 months). RESULTS: The mean value of PES/WES was 17.8 ± 2.78. All patients had a PES/WES value above 12 (threshold value defined as clinically acceptable esthetics). The mean value of PES was 9.0 ± 1.79 and the mean value of WES was 8.8 ±1.84. CONCLUSIONS: Bone augmentation of the anterior atrophic maxilla using cancellous block-allograft and late loading supports achievement of a predictable esthetic result with long-term stability of soft and hard tissues around implant-supported reconstructions.

9.
Materials (Basel) ; 13(20)2020 Oct 21.
Article de Anglais | MEDLINE | ID: mdl-33096749

RÉSUMÉ

Impression technique is one of the factors affecting restoration fit accuracy, which is a major aspect influencing its survival. The purpose of this study is to compare, in vivo, the effect of two commonly used Vinyl Polysiloxane (VPS) impression techniques on the metal framework fitting of fixed partial dentures. Ninety-two consecutive patients, diagnosed as partially edentulous, treated by fixed partial denture restorations, participated in the study. Group 1-impressions (n = 44) were subjected to the 1-step technique, while group 2 impressions (n = 48) were subjected the 2-step technique. Three accuracy assessment common methods: probe, tactile sense and radiographic test, were used to validate the clinical fit of the metal framework. Misfit was defined as even one test failure. Twenty-one (22.8%) out of 92 metal frameworks exhibited metal frameworks misfit, whereas the other 71 (77.2%) were found to be accurate. Group 1 presented significantly (p = 0.04) more metal frameworks misfit, 14/44 (31.8%) vs. 7/48 (14.6%). Restoration location (maxilla vs. mandible) had no statistically significant impact on the results (p = 0.461). The use of the VPS putty/wash 2-step impression technique is recommended to improve the clinical fit of fixed partial denture restorations.

10.
Clin Implant Dent Relat Res ; 18(6): 1142-1152, 2016 Dec.
Article de Anglais | MEDLINE | ID: mdl-26996771

RÉSUMÉ

OBJECTIVES: Radiologic and biologic assessment of immediately restored Implants combined with guided bone regeneration (GBR) and free connective tissue graft. METHODS: 1-4 year retrospective study involving 34 patients treated with maxillary immediately restored anterior single-implants. Soft tissue dimensions, radiographic bone loss, and biological and prosthetic complications were assessed. RESULTS: During the mean follow up period of 29 months the study group presented a mean mesial bone loss of 1.10 ± 0.39 mm (range: 0.5-2.4 mm), and mean distal bone loss of 1.19 ± 0.41 mm (range: 0.4-2.1 mm). Mean periimplant probing depth of 3.49 mm (SD ± 1.06) and 2.35 (SD ± 0.52) for the contralateral tooth (highly significant p < 0.001). Bleeding on probing was present in 29.4% of the examined implant supported crown sites and 10.4% of the contralateral teeth (p < 0.001). CONCLUSIONS: Anterior maxillary single-tooth replacement, using GBR and connective tissue graft according to the concept of immediate implant placement, and non-functional restoration is an accepted treatment modality achieving favorable peri-implant soft tissue condition.


Sujet(s)
Tissu conjonctif/transplantation , Pose d'implant dentaire/méthodes , Régénération tissulaire guidée parodontale/méthodes , Maxillaire/chirurgie , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Adulte d'âge moyen , Radiographie dentaire , Études rétrospectives
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE