Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 4 de 4
Filtrer
Plus de filtres











Gamme d'année
1.
Braz. J. Microbiol. ; 49(2): 392-400, Apr.-June 2018. ilus, tab, graf
Article de Anglais | VETINDEX | ID: vti-738150

RÉSUMÉ

The study of metabolomics requires extracting as many metabolites as possible from a biological sample. This study aimed to determine the optimal method for the extraction of metabolites from solid-state fermented cottonseed meal (FCSM). The UPLC-Q-TOF-MS global metabolomics technology was used to detect the metabolites in FCSM, and the extraction quantity and extraction efficiency of seven different extraction methods, specifically the WA, 50MeOH, 50MeOHB, 50MeCNB, 80MeOHB, 80MeOH and AMF methods were evaluated. The results showed that the number of VIP metabolites extracted by AMF method are 196 and 184 in ESI+ and ESI- mode respectively, it is the largest number of all exacted methods; and the AMF methods also provided a higher extraction efficiency compared with the other methods, especially in indoleacrylic acid, dl-tryptophan and epicatechin (p < 0.01). As a result, AMF/-4 °C method was identified as the best method for the extraction of metabolites from FCSM by Lactobacillus acidophilus. Our study establishes a technical basis for future metabolomics research of fermented feed.(AU)

2.
Braz. j. microbiol ; Braz. j. microbiol;49(2): 392-400, Apr.-June 2018. tab, graf
Article de Anglais | LILACS | ID: biblio-889230

RÉSUMÉ

Abstract The study of metabolomics requires extracting as many metabolites as possible from a biological sample. This study aimed to determine the optimal method for the extraction of metabolites from solid-state fermented cottonseed meal (FCSM). The UPLC-Q-TOF-MS global metabolomics technology was used to detect the metabolites in FCSM, and the extraction quantity and extraction efficiency of seven different extraction methods, specifically the WA, 50MeOH, 50MeOHB, 50MeCNB, 80MeOHB, 80MeOH and AMF methods were evaluated. The results showed that the number of VIP metabolites extracted by AMF method are 196 and 184 in ESI+ and ESI- mode respectively, it is the largest number of all exacted methods; and the AMF methods also provided a higher extraction efficiency compared with the other methods, especially in indoleacrylic acid, dl-tryptophan and epicatechin (p < 0.01). As a result, AMF/-4 °C method was identified as the best method for the extraction of metabolites from FCSM by Lactobacillus acidophilus. Our study establishes a technical basis for future metabolomics research of fermented feed.


Sujet(s)
Graines/métabolisme , Extraits de plantes/composition chimique , Gossypium/métabolisme , Métabolome , Lactobacillus acidophilus/métabolisme , Lactobacillus acidophilus/composition chimique , Spectrométrie de masse , Chromatographie , Métabolomique
3.
Braz J Microbiol ; 49(2): 392-400, 2018.
Article de Anglais | MEDLINE | ID: mdl-29154014

RÉSUMÉ

The study of metabolomics requires extracting as many metabolites as possible from a biological sample. This study aimed to determine the optimal method for the extraction of metabolites from solid-state fermented cottonseed meal (FCSM). The UPLC-Q-TOF-MS global metabolomics technology was used to detect the metabolites in FCSM, and the extraction quantity and extraction efficiency of seven different extraction methods, specifically the WA, 50MeOH, 50MeOHB, 50MeCNB, 80MeOHB, 80MeOH and AMF methods were evaluated. The results showed that the number of VIP metabolites extracted by AMF method are 196 and 184 in ESI+ and ESI- mode respectively, it is the largest number of all exacted methods; and the AMF methods also provided a higher extraction efficiency compared with the other methods, especially in indoleacrylic acid, dl-tryptophan and epicatechin (p<0.01). As a result, AMF/-4°C method was identified as the best method for the extraction of metabolites from FCSM by Lactobacillus acidophilus. Our study establishes a technical basis for future metabolomics research of fermented feed.


Sujet(s)
Gossypium/métabolisme , Lactobacillus acidophilus/composition chimique , Lactobacillus acidophilus/métabolisme , Métabolome , Extraits de plantes/composition chimique , Graines/métabolisme , Chromatographie , Spectrométrie de masse , Métabolomique
4.
Article de Anglais | VETINDEX | ID: vti-739178

RÉSUMÉ

Abstract The study of metabolomics requires extracting as many metabolites as possible from a biological sample. This study aimed to determine the optimal method for the extraction of metabolites from solid-state fermented cottonseed meal (FCSM). The UPLC-Q-TOF-MS global metabolomics technology was used to detect the metabolites in FCSM, and the extraction quantity and extraction efficiency of seven different extraction methods, specifically the WA, 50MeOH, 50MeOHB, 50MeCNB, 80MeOHB, 80MeOH and AMF methods were evaluated. The results showed that the number of VIP metabolites extracted by AMF method are 196 and 184 in ESI+ and ESI- mode respectively, it is the largest number of all exacted methods; and the AMF methods also provided a higher extraction efficiency compared with the other methods, especially in indoleacrylic acid, dl-tryptophan and epicatechin (p 0.01). As a result, AMF/-4 °C method was identified as the best method for the extraction of metabolites from FCSM by Lactobacillus acidophilus. Our study establishes a technical basis for future metabolomics research of fermented feed.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE