1.
J Clin Lab Anal ; 34(6): e23216, 2020 Jun.
Article de Anglais | MEDLINE | ID: mdl-31967356

RÉSUMÉ

BACKGROUND: Clinically, D-dimer (DD) levels are mainly used to exclude diseases such as deep venous thrombosis (DVT). In clinical testing, DD assays can be subjected to interference that may cause false results, which directly affect the clinical diagnosis. Our hypothesis was that the 95% confidence intervals (CIs) of the fibrin degradation product (FDP)/DD and fibrinogen (Fib)/DD ratios were used to identify these false results and corrected via multiple dilutions. METHODS: In total, 16 776 samples were divided into three groups according to the DD levels detected by Sysmex CS5100 and CA7000: Group A, DD ≥ 2.0 µg/mL fibrinogen equivalent unit (FEU); group B, 0.5 < DD < 2.0 µg/mL FEU; and group C, DD ≤ 0.5 µg/mL FEU. The 95% CIs of the FDP/DD and Fib/DD ratios were calculated. Six abnormal DD results were found according to the 95% CIs. For verification, we performed multiple dilutions, compared the results with those of other instruments, and tested the addition of heterophilic blocking reagent (HBR). RESULTS: The median and 95% CI of the FDP/DD ratio were 3.76 and 2.25-8.15 in group A, 5.63 and 2.86-10.58 in group B, 10.23 and 0.91-47.71 in groups C, respectively. For the Fib/DD ratio, the 95% CIs was 0.02-2.21 in group A, 0.68-8.15 in group B, and 3.82-55.27 in groups C. Six abnormal results were identified after multiple dilutions, by comparison with other detection systems, and after HBR addition. CONCLUSIONS: The FDP/DD ratio is more reliable for identifying false results. If the FDP/DD ratio falls outside the 95% CI, it should be verified by different methods.


Sujet(s)
Produits de dégradation de la fibrine et du fibrinogène/analyse , Immunoturbidimétrie/méthodes , Adulte , Artéfacts , Intervalles de confiance , Faux positifs , Femelle , Humains , Immunoturbidimétrie/normes , Mâle , Adulte d'âge moyen , Grossesse , Thrombose veineuse/sang
2.
J Clin Lab Anal ; 33(2): e22687, 2019 Feb.
Article de Anglais | MEDLINE | ID: mdl-30320416

RÉSUMÉ

BACKGROUND: Heterophilic antibodies are still an important source of interference in immunoassays, but reports of interference with D-dimers are rare. Are D-dimer level abnormalities, found in the clinic, caused by heterophilic antibodies as well, or are other mechanisms involved? We will elaborate on this issue through two different examples in this article. METHODS: Serum from two patients with significantly elevated levels of D-dimers were measured and compared by different methods, diluted, and dealt with heterophilic antibody blockers. At the same time, to retrieve the interference, we focused on the cause of D-dimer false positives and made a systematic review of the literature. RESULTS: The D-dimer values were normal (0.49 and 0.15 µg/mL) detected with different testing method and decreased after addition of heterophilic antibody blocking reagent. According to literature data, there were 66.7% (4/6) references showed the interference were heterophilic antibody. CONCLUSIONS: The influence of heterophilic antibodies on the measurement of D-dimers remains a big challenge. Different measuring instruments and methods may have significant differences in the measurement of D-dimers. By using a combination of instrumental methods for measuring, incorporating heterophilic antibody blockers, and combining with clinical performance and imaging data, most of the interference can be eliminated.


Sujet(s)
Anticorps hétérophiles/composition chimique , Anticorps hétérophiles/métabolisme , Produits de dégradation de la fibrine et du fibrinogène , Dosage immunologique/normes , Sujet âgé , Sujet âgé de 80 ans ou plus , Anticorps hétérophiles/sang , Femelle , Produits de dégradation de la fibrine et du fibrinogène/analyse , Produits de dégradation de la fibrine et du fibrinogène/composition chimique , Produits de dégradation de la fibrine et du fibrinogène/métabolisme , Humains , Dosage immunologique/méthodes , Reproductibilité des résultats
3.
Guang Pu Xue Yu Guang Pu Fen Xi ; 35(6): 1715-8, 2015 Jun.
Article de Chinois | MEDLINE | ID: mdl-26601396

RÉSUMÉ

The trace element of Manganese element in the agricultural farm (Anhui Huaiyuan Nongkang) soil was quantitatively analyzed by Laser-induced breakdown spectroscopy. The line of 403.1 nm was selected as the analysis line of Mn. The matrix element of Fe in soil was chosen as the internal calibration element and the analysis line was 407.2 nm. Ten soil samples were used to construct calibration curves with traditional method and internal standard method, and four soil samples were selected as test samples. The experimental results showed that the fitting correlation coefficient (r) is 0.954 when using the traditional method, the maximum relative error of the measurement samples is 5.72%, and the detection limit of Mn in soil is 93 mg x kg(-1). While using the internal standard method to construct the calibration curve, the fitting correlation coefficient (r) is 0.983, the relative error of measurement samples is reduced to 4.1%, and the detection limit of Mn in soil is 71 mg x kg(-1). The result indicates that LIBS technique can be used to detect trace element Mn in soil. In a certain extent, the internal standard method can improve the accuracy of measurement.