Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 7 de 7
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Adv Sci (Weinh) ; : e2309027, 2024 Sep 09.
Article de Anglais | MEDLINE | ID: mdl-39250329

RÉSUMÉ

Current methods for therapeutic drug monitoring (TDM) have a long turnaround time as they involve collecting patients' blood samples followed by transferring the samples to medical laboratories where sample processing and analysis are performed. To enable real-time and minimally invasive TDM, a microneedle (MN) biosensor to monitor the levels of two important antibiotics, vancomycin (VAN) and gentamicin (GEN) is developed. The MN biosensor is composed of a hydrogel MN (HMN), and an aptamer-functionalized flexible (Flex) electrode, named HMN-Flex. The HMN extracts dermal interstitial fluid (ISF) and transfers it to the Flex electrode where sensing of the target antibiotics happens. The HMN-Flex performance is validated ex vivo using skin models as well as in vivo in live rat animal models. Data is leveraged from the HMN-Flex system to construct pharmacokinetic profiles for VAN and GEN and compare these profiles with conventional blood-based measurements. Additionally, to track pH and monitor patient's response during antibiotic treatment, an HMN is developed that employs a colorimetric method to detect changes in the pH, named HMN-pH assay, whose performance has been validated both in vitro and in vivo. Further, multiplexed antibiotic and pH detection is achieved by simultaneously employing the HMN-pH and HMN-Flex on live animals.

2.
Adv Mater ; 36(32): e2402009, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38847967

RÉSUMÉ

Diabetic ketoacidosis (DKA), a severe complication of type 1 diabetes (T1D), is triggered by production of large quantities of ketone bodies, requiring patients with T1D to constantly monitor their ketone levels. Here, a skin-compatible hydrogel microneedle (HMN)-continuous ketone monitoring (HMN-CKM) device is reported. The sensing mechanism relies on the catechol-quinone chemistry inherent to the dopamine (DA) molecules that are covalently linked to the polymer structure of the HMN patch. The DA serves the dual-purpose of acting as a redox mediator for measuring the byproduct of oxidation of 3-beta-hydroxybutyrate (ß-HB), the primary ketone bodies; while, also facilitating the formation of a crosslinked HMN patch. A universal approach involving pre-oxidation and detection of the generated catechol compounds is introduced to correlate the sensor response to the ß-HB concentrations. It is further shown that real-time tracking of a decrease in ketone levels of T1D rat model is possible using the HMN-CKM device, in conjunction with a data-driven machine learning model that considers potential time delays.


Sujet(s)
Dopamine , Électrodes , Hydrogels , Dopamine/analyse , Animaux , Rats , Hydrogels/composition chimique , Aiguilles , Cétones/composition chimique , Catéchols/composition chimique , Catéchols/analyse , Techniques de biocapteur/instrumentation , Techniques de biocapteur/méthodes , Acidocétose diabétique/diagnostic , Acide 3-hydroxy-butyrique/composition chimique , Diabète de type 1/sang , Oxydoréduction , Diabète expérimental
3.
Adv Mater ; 36(35): e2313743, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38752744

RÉSUMÉ

Continuous monitoring of clinically relevant biomarkers within the interstitial fluid (ISF) using microneedle (MN)-based assays, has the potential to transform healthcare. This study introduces the Wearable Aptalyzer, an integrated system fabricated by combining biocompatible hydrogel MN arrays for ISF extraction with an electrochemical aptamer-based biosensor for in situ monitoring of blood analytes. The use of aptamers enables continuous monitoring of a wide range of analytes, beyond what is possible with enzymatic monitoring. The Wearable Aptalyzer is used for real-time and multiplexed monitoring of glucose and lactate in ISF. Validation experiments using live mice and rat models of type 1 diabetes demonstrate strong correlation between the measurements collected from the Wearable Aptalyzer in ISF and those obtained from gold-standard techniques for blood glucose and lactate, for each analyte alone and in combination. The Wearable Aptalyzer effectively addresses the limitations inherent in enzymatic detection methods as well as solid MN biosensors and the need for reliable and multiplexed bioanalytical monitoring in vivo.


Sujet(s)
Techniques de biocapteur , Techniques électrochimiques , Acide lactique , Aiguilles , Dispositifs électroniques portables , Animaux , Techniques de biocapteur/instrumentation , Techniques de biocapteur/méthodes , Souris , Acide lactique/analyse , Acide lactique/sang , Rats , Techniques électrochimiques/instrumentation , Techniques électrochimiques/méthodes , Aptamères nucléotidiques/composition chimique , Glucose/analyse , Glycémie/analyse , Liquide extracellulaire/composition chimique , Diabète de type 1/sang , Diabète de type 1/diagnostic
4.
Angew Chem Int Ed Engl ; 62(21): e202301624, 2023 05 15.
Article de Anglais | MEDLINE | ID: mdl-36946837

RÉSUMÉ

Point-of-care testing (POCT) of clinical biomarkers is critical to health monitoring and timely treatment, yet biosensing assays capable of detecting biomarkers without the need for costly external equipment and reagents are limited. Blood-based assays are, specifically, challenging as blood collection is invasive and follow-upprocessing is required. Here, we report a versatile assay that employs hydrogel microneedles (HMNs) to extract interstitial fluid (ISF), in a minimally invasive manner integrated with graphene oxide-nucleic acid (GO.NA)-based fluorescence biosensor to sense the biomarkers of interest in situ. The HMN-GO.NA assay is supplemented with a portable detector, enabling a complete POCT procedure. Our system could successfully measure four clinically important biomarkers (glucose, uric acid (UA), insulin, and serotonin) ex vivo, in addition, to accurately detecting glucose and UA in vivo.


Sujet(s)
Techniques de biocapteur , Acides nucléiques , Hydrogels , Glucose , Marqueurs biologiques , Sondes d'acide nucléique
5.
Adv Healthc Mater ; 12(1): e2202362, 2023 01.
Article de Anglais | MEDLINE | ID: mdl-36183355

RÉSUMÉ

Continuous glucose meters (CGMs) have tremendously boosted diabetes care by emancipating millions of diabetic patients' need for repeated self-testing by pricking their fingers every few hours. However, CGMs still suffer from major deficiencies regarding accuracy, precision, and stability. This is mainly due to their dependency on an enzymatic detection mechanism. Here a low-cost hydrogel microneedle (HMN)-CGM assay fabricated using swellable dopamine (DA)-hyaluronic acid (HA) hydrogel for glucose interrogation in dermal interstitial fluid (ISF) is introduced. Platinum and silver nanoparticles are synthesized within the 3D porous hydrogel scaffolds for nonenzymatic electrochemical sensing of the glucose. Incorporation of a highly water dispersible conductive polymer, poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS) enhances the electrical properties of HMN array, making the patch suitable as the working electrode of the sensor. The in vitro and ex vivo characterization of this newly developed HMN patch is fully studied. The performance of the HMN-CGM for real-time measurement of glucose is also shown using a rat model of type 1 diabetes. The device introduces the first HMN-based assay for tracking important disease biomarkers and expect to pave the way for next generation of polymeric-based sensors.


Sujet(s)
Glucose , Nanoparticules métalliques , Animaux , Rats , Glucose/composition chimique , Hydrogels , Argent
6.
Small ; 18(45): e2200201, 2022 11.
Article de Anglais | MEDLINE | ID: mdl-36166698

RÉSUMÉ

Conventional microneedles (MNs) have been extensively reported and applied toward a variety of biosensing and drug delivery applications. Hydrogel forming MNs with the added ability to electrically track health conditions in real-time is an area yet to be explored. The first conductive hydrogel microneedle (HMN) electrode that is capable of on-needle pH detection with no postprocessing required is presented here. The HMN array is fabricated using a swellable dopamine (DA) conjugated hyaluronic acid (HA) hydrogel, and is embedded with poly(3,4-ethylenedioxythiophene):polystyrene sulfonate (PEDOT:PSS) to increase conductivity. The catechol-quinone chemistry intrinsic to DA is used to measure pH in interstitial fluid (ISF). The effect of PEDOT:PSS on the characteristics of the HMN array such as swelling capability and mechanical strength is fully studied. The HMN's capability for pH measurement is first demonstrated using porcine skin equilibrated with different pH solutions ranging from 3.5 to 9. Furthermore, the HMN-pH meter is capable of in vivo measurements with a 93% accuracy compared to a conventional pH probe meter. This HMN technology bridges the gap between traditional metallic electrochemical biosensors and the direct extraction of ISF, and introduces a platform for the development of polymeric wearable sensors capable of on-needle detection.


Sujet(s)
Hydrogels , Aiguilles , Suidae , Animaux , Conductivité électrique , Électrodes , Concentration en ions d'hydrogène
7.
ACS Sens ; 7(8): 2387-2399, 2022 08 26.
Article de Anglais | MEDLINE | ID: mdl-35866892

RÉSUMÉ

Analyzing interstitial fluid (ISF) via microneedle (MN) devices enables patient health monitoring in a minimally invasive manner and in point-of-care settings. However, most MN-based diagnostic approaches require complicated fabrication processes and postprocessing of the extracted ISF or are limited to detection of electrochemically active biomarkers. Here, we show on-needle measurement of target analytes by integrating hydrogel microneedles with aptamer probes as the recognition elements. Fluorescently tagged aptamer probes are chemically attached to the hydrogel matrix using a simple and novel approach, while a cross-linked patch is formed. For reagentless detection, we employ a strand displacement strategy where fluorophore-conjugated aptamers are hybridized with a DNA competitor strand conjugated to a quencher molecule. The assay is utilized for rapid (2 min) measurement of glucose, adenosine triphosphate, l-tyrosinamide, and thrombin ex vivo. Furthermore, the system enables specific and sensitive quantification of rising and falling concentrations of glucose in an animal model of diabetes to track hypoglycemia, euglycemia, and hyperglycemia conditions. Our assay can be applied for rapid measurement of a diverse range of biomarkers, proteins, or small molecules, introducing a generalizable platform for biomolecule quantification, and has the potential to improve the quality of life of patients who are in need of close monitoring of biomarkers of health and disease.


Sujet(s)
Hydrogels , Qualité de vie , Animaux , Marqueurs biologiques , Fluorescence , Glucose , Oligonucléotides
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE