Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 6 de 6
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
J Dent ; 147: 105125, 2024 08.
Article de Anglais | MEDLINE | ID: mdl-38876251

RÉSUMÉ

OBJECTIVE: To compare the clinical periodontal parameters of teeth restored with a single ceramic crown, with and without crown lengthening procedure. METHODS: This prospective, longitudinal, controlled, and single-blinded clinical trial involved 22 patients with a total of forty-one teeth with ceramic crowns. The teeth were divided into two groups: test (n = 21), comprising teeth rehabilitated post crown-lengthening surgery, and control (n = 20), comprising teeth rehabilitated without crown-lengthening surgery. Plaque index (PI), gingival index (GI), probing depth (PD), bleeding on probing (BoP), and clinical attachment level (CAL) were compared between groups (surgically treated and non-surgically treated) and within each group for each type of site (treated -tt; adjacent - ad; and nonadjacent - nad). Additionally, gingival phenotype (GP), gingival recession (GR), and keratinized tissue width (KTW) were also assessed post- restoration. Statistical analyses used a significance level set at 5 %. RESULTS: PI, GI, and BoP were reduced, but no statistically significant differences were observed within each group or between groups for most follow-up periods. CAL of the TT sites was consistently higher in the test group, and PD was also higher in the test group (p < 0.05), except at T3. adPD, nadPD, adCAL, and nadCAL demonstrated no significant differences between groups and periods. A significant association was identified between GP and the occurrence of GR, with the thick-flat phenotype demonstrating less association with GR, regardless of whether crown lengthening was performed or not. CONCLUSION: Crown-lengthening surgery in rehabilitated teeth does not significantly affect PI and GI after 12 months. Although crown-lengthening surgery affected PD and CAL in TT sites, it did not affect adjacent and non-adjacent sites. CLINICAL RELEVANCE: These findings emphasize the importance of considering individual patient factors and the potential impact on periodontal tissues when planning crown-lengthening surgery. Clinicians must have a comprehensive understanding of the dynamics of the periodontal tissues involved in restorative treatments to optimize the procedure, increase success rates, and minimize potential complications.


Sujet(s)
Élongation coronaire , Couronnes , Indice de plaque dentaire , Indice parodontal , Humains , Études prospectives , Femelle , Mâle , Adulte , Élongation coronaire/méthodes , Adulte d'âge moyen , Méthode en simple aveugle , Récession gingivale/chirurgie , Céramiques/composition chimique , Études longitudinales , Gencive/chirurgie , Perte d'attache parodontale/chirurgie , Porcelaine dentaire/composition chimique , Jeune adulte , Poche parodontale/chirurgie
2.
Clin Oral Investig ; 27(5): 2207-2220, 2023 May.
Article de Anglais | MEDLINE | ID: mdl-36933047

RÉSUMÉ

OBJECTIVE: To evaluate the thermocycling effect of 3D-printed resins on flexural strength, surface roughness, microbiological adhesion, and porosity. MATERIALS AND METHODS: 150 bars (8 × 2 × 2 mm) and 100 blocks (8 × 8 × 2 mm) were made and divided into 5 groups, according to two factors: "material" (AR: acrylic resin, CR: composite resin, BIS: bis-acryl resin, CAD: CAD/CAM resin, and PRINT: 3D-printed resin) and "aging" (non-aged and aged - TC). Half of them were subjected to thermocycling (10,000 cycles). The bars were subjected to mini-flexural strength (σ) test (1 mm/min). All the blocks were subjected to roughness analysis (Ra/Rq/Rz). The non-aged blocks were subjected to porosity analysis (micro-CT; n = 5) and fungal adherence (n = 10). Data were statistically analyzed (one-way ANOVA, two-way ANOVA; Tukey's test, α = 0.05). RESULTS: For σ, "material" and "aging" factors were statistically significant (p < 0.0001). The BIS (118.23 ± 16.26A) presented a higher σ and the PRINT group (49.87 ± 7.55E) had the lowest mean σ. All groups showed a decrease in σ after TC, except for PRINT. The CRTC showed the lowest Weibull modulus. The AR showed higher roughness than BIS. Porosity revealed that the AR (1.369%) and BIS (6.339%) presented the highest porosity, and the CAD (0.002%) had the lowest porosity. Cell adhesion was significantly different between the CR (6.81) and CAD (6.37). CONCLUSION: Thermocycling reduced the flexural strength of most provisional materials, except for 3D-printed resin. However, it did not influence the surface roughness. The CR showed higher microbiological adherence than CAD group. The BIS group reached the highest porosity while the CAD group had the lowest values. CLINICAL RELEVANCE: 3D-printed resins are promising materials for clinical applications because they have good mechanical properties and low fungal adhesion.


Sujet(s)
Résines acryliques , Résistance à la flexion , Test de matériaux , Microtomographie aux rayons X , Propriétés de surface , Conception assistée par ordinateur , Impression tridimensionnelle , Couronnes
3.
Clin Oral Investig ; 26(11): 6753-6763, 2022 Nov.
Article de Anglais | MEDLINE | ID: mdl-35980474

RÉSUMÉ

OBJECTIVE: To evaluate the effect of different acid etching time and bonding agent (silane and/or adhesive system) on biaxial flexural strength and physico-chemical properties of a lithium disilicate ceramic. MATERIAL AND METHODS: One hundred twenty ceramic discs were made and divided into 8 groups (n = 15) according to factors "etching time" (20 and 120 s) with hydrofluoric acid (HF) and "bonding agent" (C, no bonding agent; S, silane, A, adhesive; and SA, silane + adhesive). After surface treatment, a resin cement layer was applied to the surface and all specimens were subjected to biaxial flexural strength (BFS) test with treated surfaces loaded in tension (1 mm/min). The Weibull analyses and complementary analyses were also performed. Statistical analysis was done with 2-way ANOVA and the Tukey test (α = 0.05). RESULTS: ANOVA revealed that the factors "etching time" (p = 0.0003) and "bonding agent" (p = 0.007) were statistically significant. In the overall analysis, the HF120S group (272.02 ± 35.30A MPa) presented significantly higher BFS than that of HF120C (218.45 ± 17.15CD MPa) and HF20S (228.40 ± 37.83BCDMPa). On the other hand, the HF20A group (208.92 ± 31.16D MPa) had significantly lower BFS than HF120S (272.02 ± 35.30A), HF120A (254.42 ± 26.87ABC) and HF120SA (259.30 ± 36.55AB) groups (Tukey). The Weibull modulus (m) of all groups was significantly different from each other (p = 0.000). CONCLUSIONS: Regardless of etching time, the application of silane alone is sufficient to increase the flexural strength of glass ceramic, eliminating the need for the application of adhesive systems. Moreover, if only silane or adhesive is applied, 120-s HF application should increase the flexural resistance of the lithium disilicate ceramic. CLINICAL SIGNIFICANCE: Applications of adhesive systems after silanization can be suppressed from the surface treatment protocol of glass ceramics, since it does not improve their mechanical strength.


Sujet(s)
Collage dentaire , Résistance à la flexion , Silanes/composition chimique , Mordançage à l'acide/méthodes , Collage dentaire/méthodes , Ciments dentaires , Propriétés de surface , Test de matériaux , Porcelaine dentaire/composition chimique , Céramiques/composition chimique , Céments résine/composition chimique , Acide fluorhydrique/composition chimique
4.
Clin Oral Investig ; 26(6): 4479-4486, 2022 Jun.
Article de Anglais | MEDLINE | ID: mdl-35435492

RÉSUMÉ

OBJECTIVE: The aim of this study was to evaluate the effect of four different finishing procedures on the fatigue strength of a fully stabilized zirconia (5Y-FSZ) material. MATERIALS AND METHODS: Disc-shaped specimens of a 5Y-FSZ (Katana UTML, Kuraray Noritake) were made (ISO 6872-2015), grinded with 600- and 1200-grit silicon carbide paper, sintered as recommended, and randomly assigned into four groups according to the finishing technique: C (control, as-sintered), P (polished with polishing rubbers), G (glaze application - powder/liquid technique), and PG (polished with polishing rubbers + glaze application - powder/liquid). Then fatigue strength (staircase method), X-ray diffraction (XRD), and scanning electron microscopy (SEM) analyses were performed. RESULTS: The C group presented the lowest fatigue strength, while the PG group presented the highest. The P and G groups presented intermediate behavior, presenting similar statistical results. XRD showed similar crystalline phase patterns for all groups. SEM images revealed some changes in the zirconia surface, with the P group presenting some scratches on the surface, while the scratches in the PG group were filled with the glaze material. CONCLUSION: None of the techniques analyzed in this study impaired the fatigue strength of fully stabilized zirconia. Importantly, the polishing rubbers combined with glaze application (PG group) improved its fatigue strength. CLINICAL RELEVANCE: The polishing rubbers followed by glaze application improve the fatigue strength in ultra-translucent zirconia.


Sujet(s)
Test de matériaux , Zirconium , Céramiques/composition chimique , Polissage dentaire , Humains , Microscopie électronique à balayage , Poudres , Propriétés de surface , Zirconium/composition chimique
5.
Clin Oral Investig ; 26(1): 889-900, 2022 Jan.
Article de Anglais | MEDLINE | ID: mdl-34448074

RÉSUMÉ

OBJECTIVE: To investigate the influence of different finishing/polishing techniques and in situ aging on the flexural strength (σ), surface roughness, and Candida albicans adherence of 5 mol% yttria-stabilized zirconia (ultratranslucent zirconia). MATERIALS AND METHODS: A total of 120 zirconia bars (Prettau Anterior, Zirkonzahn) with dimensions of 8 × 2 × 0.5 mm were divided into 8 groups (n = 15) according to two factors: "in situ aging" (non-aged and aged (A)) and "finishing/polishing" (control (C), diamond rubber polishing (R), coarse grit diamond bur abrasion (B), and coarse grit diamond bur abrasion + diamond rubber polishing (BR)). Half of the samples from each group were subjected to a 60-day in situ aging by fixing the bars into cavities prepared in the posterior region of the base of complete or partial dentures of 15 patients. The samples were then subjected to the mini flexural (σ) test (1 mm/min). A total of 40 zirconia blocks (5 × 5 × 2 mm) were prepared and subjected to roughness (Ra) analyses and fungal adherence and complementary analyses (X-ray diffraction (XRD) and scanning electron microscopy (SEM)). The data of mean σ (MPa) and roughness Ra (µm) were statistically analyzed by two-way and one-way ANOVA, respectively, and Tukey's test. The Weibull analysis was performed for σ data. The fungal adhesion (Log CFU/mL) data were analyzed by Kruskal-Wallis tests. RESULTS: For flexural resistance, the "finishing/polishing" factor was statistically significant (P = 0.0001); however, the "in situ aging" factor (P = 0.4458) was not significant. The non-aged (507.3 ± 115.7 MPa) and aged (487.6 ± 118.4 MPa) rubber polishing groups exhibited higher mean σ than the other techniques. The non-aged (260.2 ± 43.3 MPa) and aged (270.1 ± 48.8 MPa) bur abrasion groups presented lower σ. The coarse-grit diamond bur abrasion group (1.82 ± 0.61 µm) presented the highest roughness value (P = 0.001). Cell adhesion was not different among groups (P = 0.053). Group B presented the most irregular surface and the highest roughness Ra of 0.61 m. CONCLUSIONS: The finishing of ultratranslucent zirconia might be preferably done with a diamond rubber polisher. Moreover, the protocols used did not interfere with Candida albicans adhesion. CLINICAL RELEVANCE: Coarse-grit diamond burs might be avoided for finishing ultratranslucent monolithic zirconia, which might be preferably performed with a diamond rubber polisher.


Sujet(s)
Candida albicans , Résistance à la flexion , Céramiques , Polissage dentaire , Humains , Test de matériaux , Microscopie électronique à balayage , Propriétés de surface , Zirconium
6.
J Mater Sci Mater Med ; 32(6): 69, 2021 Jun 12.
Article de Anglais | MEDLINE | ID: mdl-34117934

RÉSUMÉ

To investigate the impact of radiotherapy on surface properties of restorative dental materials. A conventional resin composite-CRC (Aura Enamel), a bulk-fill resin composite-BFRC (Aura Bulk-fill), a conventional glass ionomer cement-CGIC (Riva self cure), and a resin-modified glass ionomer cement-RMGIC (Riva light cure) were tested. Forty disc-shaped samples from each material (8 mm diameter × 2 mm thickness) (n = 10) were produced according to manufacturer directions and then stored in water distilled for 24 h. Surface wettability (water contact angle), Vickers microhardness, and micromorphology through scanning electron microscopy (SEM) before and after exposition to ionizing radiation (60 Gy) were obtained. The data were statistically evaluated using the two-way ANOVA and Tukey posthoc test (p < 0.05). Baseline and post-radiation values of contact angles were statistically similar for CRC, BFRC, and RMGIC, whilst post-radiation values of contact angles were statistically lower than baseline ones for CGIC. Exposition to ionizing radiation statistically increased the microhardness of CRC, and statistically decreased the microhardness of CGIC. The surface micromorphology of all materials was changed post-radiation. Exposure to ionizing radiation negatively affected the conventional glass ionomer tested, while did not alter or improved surface properties testing of the resin composites and the resin-modified glass ionomer cement tested.


Sujet(s)
Matériaux dentaires , Tumeurs de la bouche/radiothérapie , Rayonnement ionisant , Radiothérapie/effets indésirables , Radiothérapie/méthodes , Résines synthétiques , Résines acryliques , Résines composites , Ciment ionomère au verre , Humains , Test de matériaux , Microscopie électronique à balayage , Céments résine , Silice , Contrainte mécanique , Propriétés de surface
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE