Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 15 de 15
Filtrer
1.
Article de Anglais | MEDLINE | ID: mdl-38874625

RÉSUMÉ

PURPOSE: Tibia plafond or pilon fractures present a high level of complexity, making their surgical management challenging. Three-Dimensional Virtual Planning (3DVP) can assist in preoperative planning to achieve optimal fracture reduction. This study aimed to assess the symmetry of the left and right tibial plafond and whether left-right mirroring can reliably be used. METHODS: Bilateral CT scans of the lower limbs of 75 patients without ankle problems or prior fractures of the lower limb were included. The CT images were segmented to create 3D surface models of the tibia. Subsequently, the left tibial models were mirrored and superimposed onto the right tibia models using a Coherent Point Drift surface matching algorithm. The tibias were then cut to create bone models of the distal tibia with a height of 30 mm, and correspondence points were established. The Euclidean distance was calculated between correspondence points and visualized in a boxplot and heatmaps. The articulating surface was selected as a region of interest. RESULTS: The median left-right difference was 0.57 mm (IQR, 0.38 - 0.85 mm) of the entire tibial plafond and 0.53 mm (IQR, 0.37 - 0.76 mm) of the articulating surface. The area with the greatest left-right differences were the medial malleoli and the anterior tubercle of the tibial plafond. CONCLUSION: The tibial plafond exhibits a high degree of bilateral symmetry. Therefore, the mirrored unfractured tibial plafond may be used as a template to optimize preoperative surgical reduction using 3DVP techniques in patients with pilon fractures.

2.
Am J Sports Med ; 51(14): 3724-3731, 2023 12.
Article de Anglais | MEDLINE | ID: mdl-37960850

RÉSUMÉ

BACKGROUND: Medial patellofemoral ligament (MPFL) reconstruction is associated with high complication rates because of graft overloading from incorrect graft positioning. To improve clinical outcomes, it is crucial to gain a better understanding of MPFL elongation patterns. PURPOSE: To assess MPFL length changes in healthy knees from 0° to 90° of dynamic flexion and their relationship with anatomic parameters of the patellofemoral joint. STUDY DESIGN: Descriptive laboratory study. METHODS: Dynamic computed tomography scans of an active flexion-extension-flexion movement in 115 knees from 63 healthy participants were evaluated to construct knee joint models. Using these models, the MPFL length was measured as the shortest wrapping path from the Schöttle point on the femur to 3 insertion points on the superomedial border of the patella (proximal, central, and distal). MPFL length changes (%) relative to the length in full extension were calculated, and their correlations with the tibial tuberosity-trochlear groove distance, Caton-Deschamps index, and lateral trochlear inclination were analyzed. RESULTS: The proximal fiber was the longest in full extension and progressively decreased to a median length of -6.0% at 90° of flexion. The central fiber exhibited the most isometric pattern during knee flexion, showing a median maximal decrease of 2.8% relative to the full extension length and no evident elongation. The distal fiber first slightly decreased in length but increased at deeper flexion angles. The median overall length changes were 4.6, 4.7, and 5.7 mm for the proximal, central, and distal patellar insertion, respectively. These values were either not or very weakly correlated with the tibial tuberosity-trochlear groove distance, Caton-Deschamps index, and lateral trochlear inclination when the anatomic parameters were within the healthy range. CONCLUSION: The median MPFL length changed by approximately 5 mm between 0° and 90° of flexion. Proximally, the length continuously decreased, indicating slackening behavior. Distally, the length increased at deeper flexion angles, indicating tightening behavior. CLINICAL RELEVANCE: In MPFL reconstruction techniques utilizing the Schöttle point to establish the femoral insertion, one should avoid distal patellar insertion, as it causes elongation of the ligament, which may increase the risk for complications due to overloading.


Sujet(s)
Luxation patellaire , Articulation fémoropatellaire , Humains , Articulation du genou/imagerie diagnostique , Articulation du genou/chirurgie , Ligaments articulaires/imagerie diagnostique , Ligaments articulaires/chirurgie , Articulation fémoropatellaire/imagerie diagnostique , Articulation fémoropatellaire/chirurgie , Fémur/imagerie diagnostique , Fémur/chirurgie , Patella/chirurgie , Tomodensitométrie , Luxation patellaire/chirurgie
3.
J Pers Med ; 13(2)2023 Jan 31.
Article de Anglais | MEDLINE | ID: mdl-36836512

RÉSUMÉ

Although several models for the prediction of surgical complications after primary total hip or total knee replacement (THA and TKA, respectively) are available, only a few models have been externally validated. The aim of this study was to externally validate four previously developed models for the prediction of surgical complications in people considering primary THA or TKA. We included 2614 patients who underwent primary THA or TKA in secondary care between 2017 and 2020. Individual predicted probabilities of the risk for surgical complication per outcome (i.e., surgical site infection, postoperative bleeding, delirium, and nerve damage) were calculated for each model. The discriminative performance of patients with and without the outcome was assessed with the area under the receiver operating characteristic curve (AUC), and predictive performance was assessed with calibration plots. The predicted risk for all models varied between <0.01 and 33.5%. Good discriminative performance was found for the model for delirium with an AUC of 84% (95% CI of 0.82-0.87). For all other outcomes, poor discriminative performance was found; 55% (95% CI of 0.52-0.58) for the model for surgical site infection, 61% (95% CI of 0.59-0.64) for the model for postoperative bleeding, and 57% (95% CI of 0.53-0.61) for the model for nerve damage. Calibration of the model for delirium was moderate, resulting in an underestimation of the actual probability between 2 and 6%, and exceeding 8%. Calibration of all other models was poor. Our external validation of four internally validated prediction models for surgical complications after THA and TKA demonstrated a lack of predictive accuracy when applied in another Dutch hospital population, with the exception of the model for delirium. This model included age, the presence of a heart disease, and the presence of a disease of the central nervous system as predictor variables. We recommend that clinicians use this simple and straightforward delirium model during preoperative counselling, shared decision-making, and early delirium precautionary interventions.

4.
Eur J Trauma Emerg Surg ; 49(1): 69-74, 2023 Feb.
Article de Anglais | MEDLINE | ID: mdl-35829733

RÉSUMÉ

PURPOSE: This study aims to investigate the symmetry of the left and right tibial plateau in young healthy individuals to determine whether left-right mirroring can be reliably used to optimize preoperative 3D virtual planning for patients with tibial plateau fractures. METHODS: One hundred healthy subjects, without previous knee surgery, severe knee trauma, or signs of osteoarthritis were included for a previous dynamic imaging study of the knee. The subjects underwent a CT scan, scanning the left and right knee with a slice thickness of 0.8 mm. 3D surface models of the femur, patella, and tibia were created using a convolutional neural network. The 3D models of the left and right tibias were exported to MATLAB © and the tibias were mirrored. The mirrored tibias were superimposed on the contralateral tibia using a coherent point drift surface matching algorithm. Correspondence points on both surfaces were established, the mean root squared distance was calculated and visualized in a boxplot and heatmaps. RESULTS: The overall mean difference between correspondence points on the left and right tibial plateau is 0.6276 ± 0.0343 mm. The greatest differences between correspondence points were seen around two specific surfaces on the outside of the tibial plateau; where the distal tibia was cut 15 mm below the tibial plateau and around the tibiofibular joint. CONCLUSIONS: The differences between the left and right tibial plateau are small and therefore, we can be confident that the mirrored contralateral, unfractured, tibial plateau can be used as a template for 3D virtual preoperative planning for young patients without previous damage to the knee.


Sujet(s)
Tibia , Fractures du tibia , Humains , Tibia/imagerie diagnostique , Fractures du tibia/imagerie diagnostique , Fractures du tibia/chirurgie , Articulation du genou/imagerie diagnostique , Articulation du genou/chirurgie , Fémur , Patella
5.
J Exp Orthop ; 9(1): 91, 2022 Sep 07.
Article de Anglais | MEDLINE | ID: mdl-36071256

RÉSUMÉ

PURPOSE: The aim of this study was to determine whether a flexible medial meniscus prosthesis is more capable of sharing loads with the direct tibiofemoral cartilage contact than the stiffer first-generation prosthesis. Additionally, the effect of the prosthesis on the tibial pressure distribution after total meniscectomy was investigated. METHODS: In an artificial knee joint, the relative amounts of load transferred through both meniscus prostheses and the direct tibiofemoral contact were assessed with pressure-sensitive sensors. Additionally, six cadaveric knee joints were loaded in a physiological environment. Tibial contact pressures were measured with an intact native meniscus, after total meniscectomy and after implantation of the second-generation meniscus prosthesis. RESULTS: Whereas the first generation of the meniscus prosthesis transferred virtually all the load from femur to tibia, the second-generation prosthesis allowed for load sharing with the direct tibiofemoral contact. No differences in load sharing were found between the native meniscus and the second-generation meniscus prosthesis. The prosthesis decreased peak and mean pressures on the medial tibial cartilage compared to meniscectomy. No significant differences in pressure were found between the native meniscus and the meniscus prosthesis. CONCLUSIONS: The second-generation meniscus prosthesis presented in this study can share loads with the direct tibiofemoral contact, a characteristic that the first-generation prosthesis did not have. The flexible meniscus prosthesis significantly reduces the contact pressures on the medial tibial plateau after total meniscectomy. Although the biomechanical performance of the native meniscus could not be reproduced completely, the meniscus prosthesis may have the potential to relieve post-meniscectomy pain symptoms.

6.
BMJ Open ; 12(8): e062065, 2022 08 24.
Article de Anglais | MEDLINE | ID: mdl-36002218

RÉSUMÉ

OBJECTIVE: The aim of this study was to develop prediction models for patients with total hip arthroplasty (THA) and total knee arthroplasty (TKA) to predict the risk for surgical complications based on personal factors, comorbidities and medication use. DESIGN: Retrospective cohort study. SETTING: Tertiary care in outpatient clinic of university medical centre. PARTICIPANTS: 3776 patients with a primary THA or TKA between 2004 and 2018. PRIMARY AND SECONDARY OUTCOME MEASURES: Multivariable logistic regression models were developed for primary outcome surgical site infection (SSI), and secondary outcomes venous thromboembolism (VTE), postoperative bleeding (POB), luxation, delirium and nerve damage (NER). RESULTS: For SSI, age, smoking status, body mass index, presence of immunological disorder, diabetes mellitus, liver disease and use of non-steroidal anti-inflammatory drugs were included. An area under the receiver operating characteristic curve (AUC) of 71.9% (95% CI=69.4% to 74.4%) was found. For this model, liver disease showed to be the strongest predictor with an OR of 10.7 (95% CI=2.4 to 46.6). The models for POB and NER showed AUCs of 73.0% (95% CI=70.7% to 75.4%) and 76.6% (95% CI=73.2% to 80.0%), respectively. For delirium an AUC of 85.9% (95% CI=83.8% to 87.9%) was found, and for the predictive algorithms for luxation and VTE we found least favourable results (AUC=58.4% (95% CI=55.0% to 61.8%) and AUC=66.3% (95% CI=62.7% to 69.9%)). CONCLUSIONS: Discriminative ability was reasonable for SSI and predicted probabilities ranged from 0.01% to 51.0%. We expect this to enhance shared decision-making in considering THA or TKA since current counselling is predicated on population-based probability of risk, rather than using personalised prediction. We consider our models for SSI, delirium and NER appropriate for clinical use when taking underestimation and overestimation of predicted risk into account. For VTE and POB, caution concerning overestimation exceeding a predicted probability of 0.08 for VTE and 0.05 for POB should be taken into account. Furthermore, future studies should evaluate clinical impact and whether the models are feasible in an external population.


Sujet(s)
Arthroplastie prothétique de hanche , Arthroplastie prothétique de genou , Délire avec confusion , Thromboembolisme veineux , Arthroplastie prothétique de hanche/effets indésirables , Arthroplastie prothétique de genou/effets indésirables , Délire avec confusion/complications , Humains , Pays-Bas/épidémiologie , Complications postopératoires/épidémiologie , Complications postopératoires/étiologie , Hémorragie postopératoire/épidémiologie , Études rétrospectives , Facteurs de risque , Infection de plaie opératoire/étiologie , Thromboembolisme veineux/épidémiologie , Thromboembolisme veineux/étiologie
7.
J Orthop Surg Res ; 16(1): 337, 2021 May 25.
Article de Anglais | MEDLINE | ID: mdl-34034788

RÉSUMÉ

BACKGROUND: A trochlear osteotomy aims to restore patellar stability in patients with recurrent patellar instability and trochlear dysplasia. The age of patients at time of surgery could be a relevant factor which influences outcome. We hypothesized that lower age at time of surgery is associated with better patient-reported outcomes. METHODS: A retrospective study was conducted on patients with patellar instability and trochlear dysplasia. Patients were contacted by phone for informed consent and were then asked to complete online patient-reported outcome measurements (PROMs). The PROMs consisted of the Kujala Knee Score (KKS) (Kujala et al., Arthroscopy 9(2):159-63, 1993; Kievit et al. Knee Surg Sports Traumatol Arthrosc. 21(11):2647-53, 2013), the Short Form 36-item health survey (SF-36v1) (Ware, Med Care 73-83, 1992; Aaronson et al., J Clin Epidemiol. 51(11):1055-68, 1998), and visual analog scale (VAS) scoring pain, instability, disability, and satisfaction on a 0-100 scale. Multivariable linear regression models were used to study the effect of age on the PROM scores. RESULTS: For this study, 125 surgical procedures in 113 patients were included. Mean VAS pain at rest was 19 and at activity 38; mean Kujala score was 73. Multivariable regression analysis revealed that age at the time of surgery was correlated with VAS pain at rest, with a 0.95 increase of VAS score (scale 0-100) for every year of age. Recurrence of instability was observed in 13 (10%) knees. CONCLUSION: In this cross-sectional study, pain scores of 113 patients who have undergone a lateral facet elevating trochlear osteotomy for patellar instability were reported. Age at time of surgery was correlated with an increased pain score at rest with an average of 9.5 points (scale 0-100) for every 10 years of age. Age at time of surgery was not correlated with overall satisfaction.


Sujet(s)
Instabilité articulaire/chirurgie , Ostéotomie/méthodes , Mesure de la douleur , Articulation fémoropatellaire/chirurgie , Adolescent , Adulte , Facteurs âges , Enfant , Études transversales , Femelle , Humains , Mâle , Adulte d'âge moyen , Mesures des résultats rapportés par les patients , Études rétrospectives , Jeune adulte
8.
Orthop Traumatol Surg Res ; 106(5): 957-961, 2020 Sep.
Article de Anglais | MEDLINE | ID: mdl-32753356

RÉSUMÉ

BACKGROUND: A tibial tubercle osteotomy (TTO) is a commonly performed procedure in young and active patients with patellofemoral complaints. Previous small patient series demonstrated a relatively high risk of complications, which appear to be technique dependent. The purpose of this large case series is to quantify the risk of procedure specific postoperative complications related to a uniform self-centering TTO technique in a large cohort, performed by two different surgeons in one center. HYPOTHESIS: We hypothesize that non-union or fracture occurs in less than 1% of the procedures. PATIENTS AND METHODS: Five hundred and twenty-nine knees in four hundred and forty-seven patients who underwent a self-centering TTO with at least one year of follow-up were included. We performed a retrospective cohort review. Tibial fracture, osteotomy non-union, neurovascular complications, infection and wound complications that required surgical intervention were defined as major complications, miscellaneous complications were defined minor. RESULTS: The major finding in this study is the low incidence of non-union (0.6%) and tibial fracture (0.4%). In total 9 (1.7%) major complications were reported. Minor complications included superficial wound infection in five patients, two patients had a venous thrombo-embolism (VTE). CONCLUSION: A self-centering TTO is a relatively safe technique with a low number of non-union and fracture. LEVEL OF EVIDENCE: Level IV, retrospective cohort study.


Sujet(s)
Articulation fémoropatellaire , Humains , Incidence , Ostéotomie , Études rétrospectives , Tibia/chirurgie , Résultat thérapeutique
9.
Arch Orthop Trauma Surg ; 140(12): 1867-1872, 2020 Dec.
Article de Anglais | MEDLINE | ID: mdl-32112160

RÉSUMÉ

INTRODUCTION: In patients with recurrent patellar dislocations, a tibial tubercle osteotomy (TTO) can be indicated to correct patella alta or an increased trochlear groove-tibial tubercle distance. Several surgical techniques are described. Previous studies emphasize that detaching osteotomies results in devascularisation, which can lead to non-union and tibial shaft fractures. The aim of this study was to report the complication rates directly related to the surgical technique of a V-shaped TTO, where the tubercle is completely released from its periosteum using a step-cut osteotomy. METHODS: The retrospective case series comprised a large cohort of 263 knees with patella alta in 203 patients who underwent a V-shaped TTO, with or without additional realignment procedures, between March 2004 and October 2017. Data were obtained from available patient files. Complications were defined as minor or major. RESULTS: Thirteen major complications were registered (4.9%) including two tibial fractures (0.75%) and one non-union (0.37%). Five complications (1.9%) were defined as minor. Removal of the screws because of irritation or pain was seen in 22 cases (8.2%). CONCLUSION: A V-shaped TTO is a safe procedure. The presumed higher risk for tibial fractures or pseudo-arthrosis could not be confirmed.


Sujet(s)
Ostéotomie/méthodes , Luxation patellaire/chirurgie , Complications postopératoires/épidémiologie , Tibia/chirurgie , Fractures du tibia/épidémiologie , Adolescent , Adulte , Enfant , Femelle , Fractures non consolidées/épidémiologie , Humains , Instabilité articulaire/chirurgie , Mâle , Adulte d'âge moyen , Articulation fémoropatellaire/chirurgie , Période postopératoire , Récidive , Études rétrospectives , Jeune adulte
10.
Knee Surg Sports Traumatol Arthrosc ; 28(6): 1919-1931, 2020 Jun.
Article de Anglais | MEDLINE | ID: mdl-31392368

RÉSUMÉ

PURPOSE: Recurrent patellofemoral instability is a common knee injury in skeletally immature patients. Many surgical techniques have been described in the literature, all with different success rates. Purpose of this study was to perform a systematic review and meta-analysis of the available literature to assess recurrent patellofemoral instability rates after surgical treatment using MPFL reconstruction techniques and other soft tissue realignment techniques in skeletally immature patients. METHODS: PubMed, Embase, Web of Science, and The Cochrane Library were searched to identify all original articles concerning the surgical treatment for patellofemoral instability in skeletally immature patients and that reported post-operative recurrent patellofemoral instability rates. Subsequently a risk of bias assessment was conducted and a meta-analysis was performed on reported post-operative recurrent patellofemoral instability rates after MPFL reconstruction techniques and other soft tissue realignment techniques. RESULTS: Of the 21 eligible studies (448 knees in 389 patients), 10 studies reported on MPFL reconstruction techniques using different grafts and fixation techniques and 11 reported on other soft tissue realignment procedures. In total, 62 of the 448 (13.8%) treated knees showed recurrent patellofemoral instability during follow-up. The overall pooled recurrent patellofemoral instability rate was estimated to be 0.08 (95% CI 0.02-0.16). For MPFL reconstruction techniques, the pooled recurrent patellofemoral instability rate was estimated to be 0.02 (95% CI 0.00-0.09). For the other soft tissue realignment techniques, the pooled rate was estimated to be 0.15 (95% CI 0.04-0.31). No statistically significant difference in recurrent patellofemoral instability rates between MPFL reconstruction techniques and other soft tissue realignment techniques were found (n.s.). There was a large variation in treatment effects over different settings, including what effect is to be expected in future patients. CONCLUSION: This systematic review and meta-analysis found that recurrent patellofemoral instability rates after MPFL reconstruction techniques are in the range of instability rates after other soft tissue realignment techniques. The clinical relevance of this study is that it provides clinicians with the best currently available evidence on recurrent patellofemoral instability rates after surgical treatment for patellofemoral instability in skeletally immature patients. LEVEL OF EVIDENCE: IV.


Sujet(s)
Instabilité articulaire/chirurgie , Luxation patellaire/chirurgie , Articulation fémoropatellaire/chirurgie , Humains , Instabilité articulaire/physiopathologie , Ligaments articulaires/chirurgie , Complications postopératoires , Période postopératoire , Récidive , Résultat thérapeutique
11.
Knee Surg Sports Traumatol Arthrosc ; 26(11): 3377-3385, 2018 Nov.
Article de Anglais | MEDLINE | ID: mdl-29560510

RÉSUMÉ

PURPOSE: When downsizing the femoral component to prevent mediolateral overhang, notching of the anterior femoral cortex may occur, which could be solved by flexing the femoral component. In this study, we investigated the effect of flexion of the femoral component on patellar tendon moment arm, patellofemoral forces and kinematics in posterior-referencing CR-TKA. Our hypothesis was that flexion of the femoral component increases the patellar tendon moment arm, reduces the patellofemoral forces and provides stable kinematics. METHODS: A validated musculoskeletal model of CR-TKA was used. The flexion of the femoral component was increased in four steps (0°, 3°, 6°, 9°) using posterior referencing, and different alignments were analysed in combination with three implant sizes (3, 4, 5). A chair-rising trial was analysed using the model, while simultaneously estimating quadriceps muscle force, patellofemoral contact force, tibiofemoral and patellofemoral kinematics. RESULTS: Compared to the reference case (size 4 and 0° flexion), for every 3° of increase in flexion of the femoral component the patellar tendon moment arm increased by 1% at knee extension. The peak quadriceps muscle force and patellofemoral contact force decreased by 2%, the patella shifted 0.8 mm more anteriorly and the remaining kinematics remained stable, with knee flexion. With the smaller size, the patellar tendon moment arm decreased by 6%, the quadriceps muscle force and patellofemoral contact force increased by 8 and 12%, and the patellar shifted 5 mm more posteriorly. Opposite trends were found with the bigger size. CONCLUSION: Flexing the femoral component with posterior referencing reduced the patellofemoral contact forces during a simulated chair-rising trial with a patient-specific musculoskeletal model of CR-TKA. There seems to be little risk when flexing and downsizing the femoral component, compared to when using a bigger size and neutral alignment. These findings provide relevant information to surgeons who wish to prevent anterior notching when downsizing the femoral component.


Sujet(s)
Arthroplastie prothétique de genou/méthodes , Simulation numérique , Prothèse de genou , Articulation fémoropatellaire/physiologie , Conception de prothèse , Phénomènes biomécaniques , Humains , Ligaments articulaires/physiologie , Ligament patellaire/physiologie , Muscle quadriceps fémoral/physiologie , Amplitude articulaire/physiologie
12.
J Arthroplasty ; 33(5): 1546-1551, 2018 05.
Article de Anglais | MEDLINE | ID: mdl-29306574

RÉSUMÉ

BACKGROUND: Postoperative urinary retention (POUR) appears to be a common complication in lower limb joint arthroplasty; however, reports on its incidence vary. There is no general consensus on its definition and there is no scientific evidence on treatment principles. We performed a prospective observational study to establish the incidence of POUR and its risk factors, including the preoperative postvoid residual urine volume and the perioperative fluid balance, in fast-track total joint arthroplasty (TJA). The preoperative residual urine volume and the perioperative fluid balance have not been studied in previous literature in the context of TJA and POUR. METHODS: Three hundred eighty-one patients who underwent TJA of the lower limb were observed on developing POUR according to our local treatment protocol. Data on possible risk factors for POUR were collected including the perioperative fluid balance and the preoperative residual urine volume. RESULTS: In total, 46.3% of patients were catheterized. A preoperative postvoid urine retention is a significant predictor of catheterization for postoperative residual urine (P = .03). Spinal anesthesia was correlated with urinary retention (P = .01). There was no cause-effect relationship between POUR and the perioperative fluid balance. CONCLUSION: This study underlines POUR as a common complication in fast-track lower limb arthroplasty, with spinal anesthesia as a risk factor. A higher preoperative residual urine volume leads to higher postoperative residual volume, but not to a higher change in urinary retention. Increased perioperative fluid administration is not correlated with the incidence of POUR. Furthermore, there seems to be little rationale for monitoring residual urine volume both preoperatively and postoperatively.


Sujet(s)
Arthroplastie prothétique de hanche/effets indésirables , Arthroplastie prothétique de genou/effets indésirables , Complications postopératoires/épidémiologie , Cathétérisme urinaire/statistiques et données numériques , Rétention d'urine/étiologie , Rachianesthésie/effets indésirables , Femelle , Humains , Incidence , Mâle , Période postopératoire , Études prospectives , Facteurs de risque , Vessie urinaire
13.
Knee Surg Sports Traumatol Arthrosc ; 26(9): 2841-2857, 2018 Sep.
Article de Anglais | MEDLINE | ID: mdl-29210022

RÉSUMÉ

PURPOSE: Trochleoplasty aims to restore patellar stability. Various techniques have been described and almost all authors report successful results. However, the procedure has a significant risk of complications. Purpose of this study was to perform a systematic review and meta-analysis of the available literature to assess the rate of complications after the various techniques used for trochleoplasty procedures. MATERIALS AND METHODS: MEDLINE, EMBASE, Web of Science and Cochrane Library databases were searched. Studies on patients with recurrent patellar instability treated with a trochleoplasty with or without additional procedure, and reported complications were included. The primary outcome was the rate of complications per technique. A meta-analysis was performed whenever three or more studies per surgical technique could be included. RESULTS: The selection process resulted in 20 studies included for analysis. A lateral facet elevating trochlear osteotomy was reported by two studies, ten studies reported on a Bereiter trochleoplasty, five on a Dejour trochleoplasty, one on an arthroscopic technique, one on a 'modified' technique and one on a recession wedge trochleoplasty. Meta-analysis showed that proportion of recurrent dislocation was 0.04 (95% CI 0.02-0.07) for Bereiter trochleoplasty and 0.02 (95% CI 0-0.08) for Dejour trochleoplasty. These proportions were 0.06 (95% CI 0.02-0.13) and 0.09 (95% CI 0.03-0.27) for recurrent instability, 0.07 (95% CI 0.02-0.19) and 0.12 (95% CI 0.00-0.91) for patellofemoral osteoarthritis and 0.08 (95% CI 0.04-0.14) and 0.20 (95% CI 0.11-0.32) for further surgery respectively. CONCLUSION: This study demonstrates that the complications after a Bereiter and Dejour trochleoplasty including additional procedures are in the range of those of other patellar stabilizing procedures. For four other techniques, no meta-analysis could be performed. The clinical relevance of this study is that it provides clinicians with the best currently available evidence on the rate of complications after trochleoplasty procedures. This can be helpful in the process of deciding whether or not to perform such a procedure, and can be used to better inform patients about the advantages and disadvantages of different trochleoplasty procedures. LEVEL OF EVIDENCE: Level IV.


Sujet(s)
Fémur/chirurgie , Instabilité articulaire/chirurgie , Patella/chirurgie , Luxation patellaire/chirurgie , Humains , Gonarthrose/complications , Ostéotomie/méthodes
14.
Knee Surg Sports Traumatol Arthrosc ; 26(5): 1540-1548, 2018 May.
Article de Anglais | MEDLINE | ID: mdl-28500391

RÉSUMÉ

PURPOSE: In total knee arthroplasty (TKA), the posterior tibial slope is not always reconstructed correctly, and the knee ligaments may become too tight in flexion. To release a tight flexion gap, surgeons can increase the posterior tibial slope using two surgical resection techniques: the anterior tibial cortex (ACR) or the centre of tibial plateau (CPR) referencing. It is not known how this choice affects the knee laxity and function during activities of daily living. The aim of this study was to investigate the effect of tibial slope on knee laxity, kinematics and forces during a squatting activity using computer simulation techniques. We hypothesised that the effects depend on the referencing technique utilised. METHODS: A validated musculoskeletal model of TKA was used. Knee laxity tests were simulated in flexion and extension. Then, a squat motion was simulated to calculate: movement of the tibiofemoral joint (TFJ) contact points and patello-femoral joint (PFJ) contact force. All analyses were repeated with more anterior (-3°), neutral (0°), and more posterior tibial slope (+3°, +6°, +9°), and with two referencing techniques (ACR, CPR). RESULTS: Knee laxities increased dramatically with more posterior slope with the ACR technique (up to 400%), both in flexion and in extension. The CPR technique, instead, had much smaller effects (up to 42% variations). During squatting, more slope with the ACR technique resulted in larger movements of the TFJ contact point. The PFJ contact force decreased considerably with more slope with the CPR technique (12% body weight reduction every 3° more posterior slope), thanks to the preservation of the patellar height and quadriceps-femur load sharing. CONCLUSION: ACR technique alters considerably the knee laxity, both in flexion and extensions, and surgeons should be cautious about its use. More slope with CPR technique induces more favourable TFJ kinematics and loading of the knee extensor apparatus and does not substantially alter knee laxity. Preferably, the tibial slope resection should be pre-planned thoroughly and performed using CPR technique as accurately as possible. Surgeons can directly translate the results of this study into the clinical practice.


Sujet(s)
Arthroplastie prothétique de genou , Simulation numérique , Articulation du genou/physiologie , Tibia/anatomie et histologie , Activités de la vie quotidienne , Sujet âgé , Phénomènes biomécaniques , Fémur/chirurgie , Humains , Articulation du genou/chirurgie , Ligaments articulaires/chirurgie , Patella/chirurgie , Articulation fémoropatellaire/chirurgie , Muscle quadriceps fémoral/physiologie , Amplitude articulaire , Tibia/chirurgie
15.
Knee Surg Sports Traumatol Arthrosc ; 21(11): 2647-53, 2013 Nov.
Article de Anglais | MEDLINE | ID: mdl-24026342

RÉSUMÉ

PURPOSE: To translate and validate the Kujala Anterior Knee Pain Scale (AKPS) in patients who have undergone total knee arthroplasty (TKA) or unicompartmental knee arthroplasty (UKA) and evaluate the internal consistency, construct validity and ceiling or floor effect. METHODS: After standard forward and backward translation was performed, 302 patients who have received a TKA or UKA filled out the AKPS together with Hospital for Special Surgery (HSS) patella score, visual analogue score (VAS) for pain, the Oxford 12-item questionnaire and the SF-36 at follow-up. The internal consistency was tested using Cronbach's α coefficient. The construct validity was assessed using Spearman's rank correlation (R) to test for correlations between the AKPS and VAS HSS, HSS patella score, VAS month, Oxford 12-item questionnaire and SF-36 subscales. Ceiling or floor effects are given in percentage of patients giving a maximum or minimum score. RESULTS: The internal reliability of the AKPS is acceptable with a Cronbach's α of 0.81 in patients after TKA or UKA. A high correlation was found between the AKPS and the Oxford 12-item questionnaire (R = 0.81). Moderate correlations were found with the VAS month (R = 0.63), HSS patella score (R = 0.51) and SF-36 subscales physical functioning (R = 0.59), role-physical (R = 0.59), bodily pain (R = 0.57). Other correlations were poor, therefore indicating a good convergent and divergent validity. Ceiling effects were observed for the HSS patella score (31 %), VAS HSS (51 %), VAS pain (19 %), SF36-RP (46 %), SF36-RE (80 %) and SF36-BP (24 %). No ceiling or floor effect was found for the AKPS, Oxford 12-item and the other SF36 domains. CONCLUSIONS: The AKPS appears to be reliable and valid in patients after knee arthroplasty, with no ceiling and floor effects, and can be used to assess anterior knee pain in patient who underwent joint replacement surgery.


Sujet(s)
Arthralgie/chirurgie , Arthroplastie prothétique de genou , Articulation du genou/chirurgie , Gonarthrose/chirurgie , Enquêtes et questionnaires , Humains , Pays-Bas , Reproductibilité des résultats , Traductions
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...