Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 510
Filtrer
1.
Arq. bras. cardiol ; Arq. bras. cardiol;121(8): e20230771, ago. 2024. tab, graf
Article de Portugais | LILACS-Express | LILACS | ID: biblio-1568816

RÉSUMÉ

Resumo Fundamento A frequência cardíaca (FC) na insuficiência cardíaca com fração de ejeção reduzida (ICFEr) e ritmo sinusal apresenta valor prognóstico. Entretanto, o método de mensuração é debatido na literatura. Objetivos Comparar em pacientes com ICFEr e ritmo sinusal a FC no Holter com três eletrocardiogramas de repouso: ECG1, ECG2 e ECG3. Metodologia Estudo transversal com 135 pacientes portadores de insuficiência cardíaca com fração de ejeção ≤ 40% e ritmo sinusal. A FC foi avaliada por ECG e Holter. Análises incluíram o coeficiente de correlação intraclasse (CCI), regressão robusta, raiz do erro quadrático médio, Bland-Altman e a área sobre a curva ROC. Adotou-se nível de significância de 0,05 e o ajuste de Bonferroni-Holm para minimizar erros tipo I. Resultados As medianas [intervalo interquartil] de idade e fração de ejeção foram de 65 anos [16] e 30% [11], respectivamente. O CCI dos 3 ECG foi de 0,922 (intervalo de confiança de 95%: 0,892; 0,942). Os coeficientes de regressão robusta para ECG1 e ECG3 foram 0,20 (intervalo de confiança de 95%: 0,12; 0,29) e 0,21 (intervalo de confiança de 95%: 0,06; 0,36). O R2 robusto foi de 0,711 (intervalo de confiança de 95%: 0,628; 0,76). Na análise de concordância de Bland-Altman, os limites de concordância foram de −17,0 (intervalo de confiança de 95%: −19,0; −15,0) e 32,0 (intervalo de confiança de 95%: 30,0; 34,0). A área sob a curva ROC foi de 0,896 (intervalo de confiança de 95%: 0,865; 0,923). Conclusão A FC do ECG mostrou alta concordância com a FC do Holter, validando seu uso clínico em pacientes com ICFEr e ritmo sinusal. Contudo, a concordância foi subótima em um terço dos pacientes com FC inferior a 70 bpm pelo ECG, devendo ser considerada a realização de Holter neste contexto.


Abstract Background Heart rate (HR) has shown prognostic value in patients with heart failure with reduced ejection fraction (HFrEF) and sinus rhythm. However, the method of measurement is debated in the literature. Objectives To compare HR on Holter with 3 resting electrocardiograms (ECG1, ECG2, and ECG3) in patients with HFrEF and sinus rhythm. Methods This was a cross-sectional study with 135 patients with heart failure with ejection fraction ≤ 40% and sinus rhythm. HR was assessed by ECG and Holter. Analyses included intraclass correlation coefficient (ICC), robust regression, root mean squared error, Bland-Altman, and area under the receiver operating characteristic (ROC) curve. A significance level of 0.05 and Bonferroni-Holm adjustment were adopted to minimize type I errors. Results The median [interquartile range] age and ejection fraction were 65 years [16] and 30% [11], respectively. The ICC of the 3 ECGs was 0.922 (95% confidence interval: 0.892; 0.942). The robust regression coefficients for ECG1 and ECG3 were 0.20 (95% confidence interval: 0.12; 0.29) and 0.21 (95% confidence interval: 0.06; 0.36). The robust R2 was 0.711 (95% confidence interval: 0.628; 0.76). In the Bland-Altman agreement analysis, the limits of agreement were −17.0 (95% confidence interval: −19.0; −15.0) and 32.0 (95% confidence interval: 30.0; 34.0). The area under the ROC curve was 0.896 (95% confidence interval: 0.865; 0.923). Conclusion The HR on ECG showed high agreement with the HR on Holter, validating its clinical use in patients with HFrEF and sinus rhythm. However, agreement was suboptimal in one third of patients with HR below 70 bpm on ECG; thus, 24-hour Holter monitoring should be considered in this context.

2.
J Electrocardiol ; 85: 7-15, 2024.
Article de Anglais | MEDLINE | ID: mdl-38810594

RÉSUMÉ

INTRODUCTION: The electrocardiogram (ECG) is a valuable tool for interpreting ventricular repolarization. This article aims to broaden the diagnostic scope beyond the conventional ischemia-centric approach, integrating an understanding of pathophisiological influences on ST-T wave changes. METHODS: A review was conducted on the physiological underpinnings of ventricular repolarization and the pathophisiological processes that can change ECG patterns. The research encompassed primary repolarization abnormalities due to uniform variations in ventricular action potential, secondary changes from electrical or mechanical alterations, and non-ischemic conditions influencing ST-T segments. RESULTS: Primary T waves are characterized by symmetrical waves with broad bases and variable QT intervals, indicative of direct myocardial action potential modifications due to ischemia, electrolyte imbalances, and channelopathies. Secondary T waves are asymmetric and often unassociated with significant QT interval changes, suggesting depolarization alterations or changes in cardiac geometry and contractility. CONCLUSION: We advocate for a unified ECG analysis, recognizing primary and secondary ST-T changes, and their clinical implications. Our proposed analytical framework enhances the clinician's ability to discern a wide array of cardiac conditions, extending diagnostic accuracy beyond myocardial ischemia.


Sujet(s)
Électrocardiographie , Humains , Troubles du rythme cardiaque/physiopathologie , Troubles du rythme cardiaque/diagnostic , Système de conduction du coeur/physiopathologie , Potentiels d'action
3.
Ann Noninvasive Electrocardiol ; 29(3): e13116, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38627955

RÉSUMÉ

PURPOSE: Acquired QT prolongation is frequent and leads to a higher mortality rate in critically ill patients. KardiaMobile 1L® (KM1L) is a portable, user-friendly single lead, mobile alternative to conventional 12-lead electrocardiogram (12-L ECG) that could be more readily available, potentially facilitating more frequent QTc assessments in intensive care units (ICU); however, there is currently no evidence to validate this potential use. METHODS: We conducted a prospective diagnostic test study comparing QT interval measurement using KM1L with conventional 12-L ECG ordered for any reason in patients admitted to an ICU. We compared the mean difference using a paired t-test, agreement using Bland-Altman analysis, and Lin's concordance coefficient, numerical precision (proportion of QT measurements with <10 ms difference between KM1L and conventional 12-L ECG), and clinical precision (concordance for adequate discrimination of prolonged QTc). RESULTS: We included 114 patients (61.4% men, 60% cardiovascular etiology of hospitalization) with 131 12-L ECG traces. We found no statistical difference between corrected QT measurements (427 ms vs. 428 ms, p = .308). Lin's concordance coefficient was 0.848 (95% CI 0.801-0.894, p = .001). Clinical precision was excellent in males and substantial in females (Kappa 0.837 and 0.781, respectively). Numerical precision was lower in patients with vasoactive drugs (-13.99 ms), QT-prolonging drugs (13.84 ms), antiarrhythmic drugs (-12.87 ms), and a heart rate (HR) difference of ≥5 beats per minute (bpm) between devices (-11.26 ms). CONCLUSION: Our study validates the clinical viability of KM1L, a single-lead mobile ECG device, for identifying prolonged QT intervals in ICU patients. Caution is warranted in patients with certain medical conditions that may affect numerical precision.


Sujet(s)
Électrocardiographie , Syndrome du QT long , Mâle , Femelle , Humains , Maladie grave , Études prospectives , Syndrome du QT long/diagnostic , Rythme cardiaque/physiologie
4.
Front Cardiovasc Med ; 11: 1265089, 2024.
Article de Anglais | MEDLINE | ID: mdl-38682099

RÉSUMÉ

Deep brain stimulation (DBS) is an interdisciplinary and reversible therapy that uses high-frequency electrical stimulation to correct aberrant neural pathways in motor and cognitive neurological disorders. However, the high frequency of the waves used in DBS can interfere with electrical recording devices (e.g., electrocardiogram, electroencephalogram, cardiac monitor), creating artifacts that hinder their interpretation. The compatibility of DBS with these devices varies and depends on factors such as the underlying disease and the configuration of the neurostimulator. In emergencies where obtaining an electrocardiogram is crucial, the need for more consensus on reducing electrical artifacts in patients with DBS becomes a significant challenge. Various strategies have been proposed to attenuate the artifact generated by DBS, such as changing the DBS configuration from monopolar to bipolar, temporarily deactivating DBS during electrocardiographic recording, applying frequency filters both lower and higher than those used by DBS, and using non-standard leads. However, the inexperience of medical personnel, variability in DBS models, or the lack of a controller at the time of approach limit the application of these strategies. Current evidence on their reproducibility and efficacy is limited. Due to the growing elderly population and the rising utilization of DBS, it is imperative to create electrocardiographic methods that are easily accessible and reproducible for general physicians and emergency services.

5.
Diagnostics (Basel) ; 14(6)2024 Mar 12.
Article de Anglais | MEDLINE | ID: mdl-38535021

RÉSUMÉ

Numerous papers report the efficiency of the automatic interpretation capabilities of commercial algorithms. Unfortunately, these algorithms are proprietary, and academia has no means of directly contributing to these results. In fact, nothing at the same stage of development exists in academia. Despite the extensive research in ECG signal processing, from signal conditioning to expert systems, a cohesive single application for clinical use is not ready yet. This is due to a serious lack of coordination in the academic efforts, which involve not only algorithms for signal processing, but also the signal acquisition equipment itself. For instance, the different sampling rates and the different noise levels frequently found in the available signal databases can cause severe incompatibility problems when the integration of different algorithms is desired. Therefore, this work aims to solve this incompatibility problem by providing the academic community with a diagnostic-grade electrocardiograph. The intention is to create a new standardized ECG signals database in order to address the automatic interpretation problem and create an electrocardiography system that can fully assist clinical practitioners, as the proprietary systems do. Achieving this objective is expected through an open and coordinated collaboration platform for which a webpage has already been created.

6.
An. Fac. Med. (Perú) ; 85(1): 62-65, ene.-mar. 2024. graf
Article de Espagnol | LILACS-Express | LILACS | ID: biblio-1556802

RÉSUMÉ

RESUMEN El neumotórax espontáneo es una entidad poco frecuente, y es poco frecuente su asociación con los cambios electrocardiográficos. En estos casos, las anormalidades más frecuentes son la elevación del segmento ST, la inversión de la onda T y la pobre progresión de la onda R en derivaciones precordiales. Presentamos el caso de un varón de 25 años quien presentó un neumotórax espontáneo izquierdo, a su ingreso el paciente tuvo un electrocardiograma con infradesnivel en el segmento ST en derivaciones inferiores, hallazgos que resolvieron posterior al tratamiento del neumotórax con una toracotomía.


ABSTRACT Spontaneous pneumothorax is a rare entity, and its association with electrocardiographic changes is infrequent. In these cases, the most frequent abnormalities are ST-segment elevation, T-wave inversion and poor R wave progression in precordial leads. We present the case of a 25-year-old man who experienced a left spontaneous pneumothorax secondary to a subpleural bleb. Upon admission, his electrocardiogram revealed ST-segment depression in the inferior leads and aVF. These findings resolved following management of pneumothorax through thoracotomy.

8.
Front Biosci (Landmark Ed) ; 29(1): 46, 2024 01 24.
Article de Anglais | MEDLINE | ID: mdl-38287805

RÉSUMÉ

BACKGROUND: Cardiovascular diseases (CVDs) are the leading cause of women's mortality, linked to aging and reduced estrogen during menopause. Estrogen replacement therapy (ERT) is suggested for CVDs prevention. Yet, its timing initiation remains contentious. Thus, we aimed to evaluate the effect of early and late estrogen therapy on cardiac function and lipid metabolism in ovariectomized old female Wistar rats. METHODS: Fifty randomized female Wistar rats were included in 5 groups (n = 10, 18 months old): (1) Sham, (2) 10 weeks post ovariectomy (Ovx-10 w), (3) 10 weeks post Ovx + early estrogen replacement therapy (Ovx 10 w-early ERT), (4) 20 weeks post Ovx (Ovx-20 w) and (5) Ovx 20 w-late ERT. Three days (early ERT) or 10 weeks (late ERT) after surgery 17-ß estradiol was given (5 µg/kg/day), and 10 weeks after the start of ERT, we assessed cardiac function by echocardiography, electrocardiography, and cardiac catheterization. Estradiol, cholesterol, triglyceride (TG), high-density lipoprotein (HDL) and low-density lipoprotein (LDL) levels were determined. Cardiac histology was performed with Masson's staining. RESULTS: Ovariectomy (Ovx) increases left ventricle internal systolic diameter (0.4 vs 0.3 cm, *p = 0.020) and decreases shortening fraction (40 vs 54 %, *p = 0.030) regardless of therapy. ERT prevents the increase in left ventricle mass after 10 weeks post-Ovx and the ejection fractionreduction after 20 weeks. Lower P wave amplitudes (18.8 vs 24.2 ms, *p = 0.013) were found in the Ovx-20 w group. A longer duration of the QRS complex after 20 weeks post-Ovx with and without ERT was found (32.5 and 32.1 vs 28.3 ms, *p = 0.003; *p = 0.007). Diastolic blood pressure was higher 20 weeks post-Ovx (86 vs 76 mmHg, *p = 0.047), regardless of ERT. The left ventricle (LV) -dP/dt was decreased in Ovx groups without ERT (-750 vs -1320 mmHg, *p = 0.034). An increase in LV collagen deposition was found in the Ovx 10 w group vs Sham (9.58 vs 4.54 %, *p = 0.028). Early ERT avoids the increase in body weight, cholesterol and LDL caused by Ovx. CONCLUSIONS: Ovariectomy causes time-dependent alterations in lipid metabolism, morphology, electrical activity, and heart contractile function. Early but not late ERT prevents some of these effects.


Sujet(s)
Oestrogénothérapie substitutive , Cardiopathies , Humains , Rats , Animaux , Femelle , Nourrisson , Rat Wistar , Ovariectomie , Oestradiol/pharmacologie , Vieillissement , Pression sanguine , Oestrogènes , Cholestérol
10.
Arq. bras. cardiol ; Arq. bras. cardiol;121(1): e20230098, jan. 2024. tab, graf
Article de Portugais | LILACS-Express | LILACS | ID: biblio-1533731

RÉSUMÉ

Resumo Fundamento Pacientes com idade superior a 50 anos requerem quatro vezes mais intervenções cirúrgicas que o grupo mais jovem. Muitas diretrizes recomendam a realização do eletrocardiograma pré-operatório nessa faixa etária. Objetivos Determinar a importância do ECG pré-operatório em pacientes com idade superior a 50 anos e com classificação de risco cirúrgico ASA I e II. Métodos Foram recrutados pacientes com idade superior a 50 anos, sem comorbidades, submetidos à intervenção cirúrgica sob anestesia geral. Os pacientes foram randomizados para a realização (grupo A n=214) ou não (grupo B n=213) do ECG pré-operatório. Foram analisadas as variáveis: sexo, idade, resultado do ECG, da radiografia do tórax e dos exames laboratoriais, risco cirúrgico, duração do procedimento, eventos adversos e mortalidade intra-hospitalar. O nível de significância estatística adotado foi de 5%. Resultados Houve ocorrência de desfechos adversos em 23 (5,4%) pacientes, com um número significante de eventos adversos nos pacientes do sexo masculino (OR=7,91, IC95% 3,3-18,90, p<0,001) e naqueles com intervenções de maior porte cirúrgico (OR=30,02, IC95% 4,01-224,92, p<0,001). Não houve diferença entre os grupos que realizaram ou não o ECG (OR=1,59, IC95% 0,67-3,75, p=0,289). As demais variáveis não mostraram diferenças significantes. Na regressão logística multivariada o sexo masculino (OR=6,49; IC95% 2,42-17,42, p<0,001) e o porte cirúrgico (OR=22,62; IC95% 2,95-173,41, p=0,002) foram preditores independentes de desfechos adversos, enquanto realizar ou não ECG (OR=1,09; IC95% 0,41-2,90, p=0,867) permaneceu sem significância estatística. Conclusões Os resultados sugerem que o ECG pré-operatório não foi capaz de predizer aumento do risco de desfechos adversos nos pacientes estudados, durante a fase hospitalar.


Abstract Background Patients aged over 50 years require four times more surgical interventions than younger groups. Many guidelines recommend the performance of preoperative electrocardiogram (ECG) in this population. Objectives To determine the value of preoperative ECG in patients aged over 50 years and classified as ASA I-II (surgical risk). Methods Patients older than 50 years, without comorbidities, who underwent surgical intervention and general anesthesia were included in the study. Patients were randomized to undergo ECG (group A, n=214) or not (group B, n=213) in the preoperative period. The following variables were analyzed: sex, age, ECG, chest x-ray and laboratory tests results, surgical risk, surgery duration, adverse events and in-hospital mortality. The level of significance was set at 5%. Results Adverse outcomes were reported in 23 (5.4%) patients, with a significant number of adverse events in male patients (OR=7.91 95%CI 3.3-18.90, p<0.001) and in those undergoing major surgeries (OR=30.02 95%CI 4.01-224.92, p<0.001). No differences were observed between patients who underwent ECG and those who did not (OR=1.59, 95%CI, 0.67-3.75, p=0.289). No significant differences were found in the other variables. In multivariate logistic regression, male sex (OR = 6.49; 95%CI 2.42-17.42, p<0.001) and major surgery (OR=22.62; 95%CI 2.95-173.41, p=0.002) were independent predictors of adverse outcomes, whereas undergoing (or not) ECG (OR=1.09; IC95% 0.41-2.90, p=0.867) remained without statistical significance. Conclusion Our findings suggest that preoperative ECG could not predict an increased risk of adverse outcomes in our study population during the hospital phase.

11.
J Pediatr ; 265: 113814, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-37918518

RÉSUMÉ

OBJECTIVES: To assess whether right atrial enlargement (RAE) on electrocardiogram (ECG) correlates with true RAE on echocardiogram in previously healthy young patients and to understand which patients with RAE on ECG may warrant additional testing. STUDY DESIGN: A single-center, retrospective review of previously healthy young patients with (1) ECGs that were read as RAE by a pediatric cardiologist and (2) echocardiograms obtained within 90 days of the ECG. ECGs were reviewed to confirm RAE and determine which leads met criteria. The echocardiograms were then reviewed and RA measurements with z scores obtained. A z score >2 was considered positive for RAE on echocardiogram. RESULTS: In total, 162 patients with median age 10.8 years were included in the study. A total of 23 patients had true RAE on echocardiogram, giving a positive predictive value (PPV) of 14%. In patients <1 year of age, the PPV increased to 35%. In patients older than 1 year, the PPV was low at 7%. Patients with true RAE were more likely to meet criteria for RAE in the anterior precordial leads (V1-V3) (48% vs 5%, P < .001) and meet criteria for right ventricular hypertrophy (22% vs 6%, P = .023). CONCLUSION: Our findings show that RAE on ECG has a low PPV for RAE on echocardiogram in previously healthy young patients. The highest yield for RAE on echocardiogram was observed in patients who were <1 year of age, had RAE in the anterior precordial leads, or displayed right ventricular hypertrophy on ECG.


Sujet(s)
Électrocardiographie , Hypertrophie ventriculaire droite , Enfant , Humains , Hypertrophie ventriculaire droite/imagerie diagnostique , Cardiomégalie/imagerie diagnostique , Échocardiographie , Études rétrospectives
12.
Int. j. cardiovasc. sci. (Impr.) ; 37: e20220179, 2024. tab, graf
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1534612

RÉSUMÉ

Abstract Background: People with haemophilia (PwH) are living longer. Therefore, they can develop atherosclerotic cardiovascular disease (ASCVD). Electrocardiogram (ECG) alterations may be a sign of initial ASCVD before the occurrence of symptoms. Objective: To describe the prevalence of resting ECG alterations among PwH adults asymptomatic for ASCVD. Methods: PwH aged ≥ 30 years without previous ASCVD events were considered for the analysis. Resting ECG traces were analysed according to international reference values and the Brazilian Longitudinal Adult Health Study (ELSA-Brasil) results for asymptomatic Brazilian men. Based on the established normal values and using the QT index, we further described the altered ECGs as minor or major changes, according to the Minnesota Code. Differences between prevalences were evaluated by Pearson's χ2 test. Differences between medians were evaluated by the Mann-Whitney U test. A p-value < 0.05 was accepted as statistically significant. Results: A total of 64 PwH were included in the study. Median age was 44 years (interquartile range 35-52). Most patients had haemophilia A (81%) and 47% were severe. The prevalence of obesity, systemic arterial hypertension (SAH), diabetes mellitus (DM), and dyslipidaemia were 16%, 56%, 14%, and 72%, respectively. All the PwH had sinus rhythm, except for one, who had an implanted pacemaker due to idiopathic third-degree atrioventricular block. Altered ECGs were found in 25% and 30% of PwH, according to established criteria and ELSA-Brasil criteria, respectively. Major changes were found in eight (13%) PwH according to the Minnesota Code, including two ECGs with ischaemia-like wall inactivity. Conclusions: The prevalence of altered ECG varied from 25% to 30% among asymptomatic PwH.

13.
Int. j. cardiovasc. sci. (Impr.) ; 37: e20230105, 2024. tab, graf
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1534624

RÉSUMÉ

Abstract Background A recently identified viral illness called coronavirus disease 2019 (COVID-19) is spreading quickly. Numerous cardiovascular issues such as arrhythmias and electrocardiogram (ECG) alterations have been linked to COVID-19. Objective In this investigation, we compared ECG indicators of depolarization and repolarization heterogeneity between symptomatic individuals who complained of palpitations and chest discomfort following COVID-19 and those who did not. Methods In this prospective case-control study, 56 post-COVID-19 patients who did not have any symptoms of chest discomfort or palpitations were included in the control group and compared with a study group comprising 73 post-COVID-19 patients who presented at the outpatient clinic with complaints of chest pain and palpitation. Electrocardiographic (ECG) measures were used to assess depolarization and repolarization of the ventricles. These measures included the Tpeak-Tend (Tp-e) interval, QT dispersion (QTd), Tp-e/QT ratio, Tp-e/QTc ratio, frontal QRS-T (fQRS-T) angle, and fragmented QRS (FQRS). Two cardiologists recorded the patients' ECG data. A statistically significant result was defined as a p value less than 0.05. Results The results of multivariate analysis including FQRS, Tp-e interval, Tp-e/QT, and Tp-e/cQT showed that presence of FQRS (OR: 6.707, 95% CI: 1.733-25.952; p = 0.006) was an independent predictor of symptomatic post-COVID -19 patients. Conclusion In our study, FQRS was found to be significantly higher in symptomatic post-COVID-19 patients than in non-symptomatic post-COVID-19 patients, while Tp-e interval was found to be lower.

14.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);70(2): e20230742, 2024. tab
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1529382

RÉSUMÉ

SUMMARY OBJECTIVE: Sudden unexpected death in epilepsy is the most common cause of death in young patients with epilepsy. The aim of this study was to evaluate changes in interictal electrocardiogram parameters and sympathetic skin responses as markers of autonomic dysfunction in patients with epilepsy and to determine their effects on the type and duration of epilepsy, frequency of seizures, and responses to treatment. METHODS: A total of 97 patients with epilepsy and 94 healthy controls were recruited. We recorded their clinical and demographic characteristics and analyzed sympathetic skin response latency and amplitude, electrocardiogram recordings, and seven cardiac rhythm parameters: P-wave duration, PR segment, QRS duration, QT interval, QT interval distribution, Tpe duration, and Tpe/QT interval ratio. RESULTS: P-wave durations, T-wave durations, QT and QT interval durations, and Tpe and sympathetic skin response latency were significantly longer among patients with epilepsy than the controls, and their heart rate was significantly lower. However, sympathetic skin response latency and heart rate were negatively correlated, and T-wave duration, QT duration, QT interval duration, and Tpe were positively correlated. CONCLUSION: Our results from interictal electrocardiograms indicate clinically significant arrhythmias among patients with epilepsy and the correlation of such arrhythmias with sympathetic skin responses. Thus, noninvasive tests that evaluate the autonomic system should be used to predict the risk of sudden unexpected death in epilepsy among patients with epilepsy.

15.
Arq. bras. cardiol ; Arq. bras. cardiol;121(5): e20230733, 2024. graf
Article de Portugais | LILACS-Express | LILACS, SESSP-IDPCPROD, Sec. Est. Saúde SP | ID: biblio-1563909

RÉSUMÉ

Resumo Embora o modelo existente de classificação do infarto agudo do miocárdio (IAM) em IAMCSST e IAMSSST tenha sido benéfico, considera-se hoje que ele falha em abordar a complexidade das síndromes coronarianas agudas. O estudo tem como objetivo examinar o atual paradigma IAMCSST-IAMSSST e defender um modelo mais detalhado, chamado de oclusão coronariana aguda (OCA) e Ausência de Oclusão Coronária Aguda (NOCA), para um diagnóstico e um manejo do IAM mais precisos. Realizou-se uma análise abrangente da literatura médica existente, com foco nas limitações do modelo IAMCSST-IAMSSST. O estudo também descreve uma nova abordagem diagnóstica para pacientes apresentando do torácica nos departamentos de emergência. O modelo IAMCSST-IAMSSST tradicional falha em prover um diagnóstico preciso e um tratamento efetivo, principalmente na identificação de oclusões da artéria coronária. O modelo OCA-NOCA é mais preciso em termos anatômicos e fisiológicos, e apoiado por pesquisa clínica extensa e opiniões de especialistas. Ele destaca a necessidade de rápida realização de eletrocardiogramas (ECGs) e terapias de reperfusão para casos suspeitos de OCA, visando melhorar os desfechos dos pacientes. O modelo OCA-NOCA abre um novo caminho para pesquisas e aplicações clínicas futuras. Ele defende um entendimento mais abrangente dos mecanismos subjacentes das síndromes coronarianas agudas, levando a planos individualizados de tratamentos. Espera-se que essa nova abordagem incite novos debates e pesquisas acadêmicas, principalmente na área de cardiologia no Brasil, com o objetivo de aumentar a precisão diagnóstica e a eficácia do tratamento de pacientes com IAM.


Abstract Although the existing framework for classifying acute myocardial infarction (AMI) into STEMI and NSTEMI has been beneficial, it is now considered to be falling short in addressing the complexity of acute coronary syndromes. The study aims to scrutinize the current STEMI-NSTEMI paradigm and advocate for a more nuanced framework, termed as occlusion myocardial infarction (OMI) and non-occlusion myocardial infarction (NOMI), for a more accurate diagnosis and management of AMI. A comprehensive analysis of existing medical literature was conducted, with a focus on the limitations of the STEMI-NSTEMI model. The study also outlines a new diagnostic approach for patients presenting with chest pain in emergency settings. The traditional STEMI-NSTEMI model falls short in diagnostic precision and effective treatment, especially in identifying acute coronary artery occlusions. The OMI-NOMI framework offers a more anatomically and physiologically accurate model, backed by a wealth of clinical research and expert opinion. It underscores the need for quick ECG assessments and immediate reperfusion therapies for suspected OMI cases, aiming to improve patient outcomes. The OMI-NOMI framework offers a new avenue for future research and clinical application. It advocates for a more comprehensive understanding of the underlying mechanisms of acute coronary syndromes, leading to individualized treatment plans. This novel approach is expected to ignite further scholarly debate and research, particularly in the Brazilian cardiology sector, with the goal of enhancing diagnostic accuracy and treatment effectiveness in AMI patients.

17.
Arq. bras. cardiol ; Arq. bras. cardiol;121(2): e20230483, 2024. tab, graf
Article de Portugais | LILACS-Express | LILACS | ID: biblio-1557002

RÉSUMÉ

Resumo Fundamento: Distrofia Muscular de Duchenne (DMD) é uma doença neuromuscular hereditária rara. O acometimento cardíaco inicial pode ser assintomático. Portanto, a avaliação por métodos não invasivos pode auxiliar sua abordagem. Objetivos: Analisar o eletrocardiograma (ECG) e a variabilidade da frequência cardíaca (VFC) do grupo com DMD, e comparar com a do grupo controle pareado por idade. Métodos: Estudo prospectivo com 27 pacientes masculinos com DMD (idade de 11,9 anos) que foram submetidos à avaliação clínica, ECG, ecocardiograma e Holter. ECG (aumento de 200%) foi avaliado por dois observadores independentes. VFC foi feita no domínio do tempo (24 h) e da frequência na posição supina e sentada. O grupo saudável foi de nove pacientes (11,0 anos). Um valor de p < 0,05 foi considerado estatisticamente significante. Resultados: A média da fração de ejeção (FE) foi de 60% (34 a 71%). O coeficiente de Kappa para as medidas do ECG variou de 0,64 a 1,00. Foram verificados aumento da relação R/S em V1 em 25,9%, onda Q patológica em 29,6% e QRS fragmentado em 22,2% em regiões inferior/lateral alta, este com correlação negativa com FE (p = 0,006). Houve baixa VFC, sem influência de nenhuma variável, inclusive tratamento. Com a mudança da posição, houve aumento da FC (p = 0,004), porém não houve alteração da VFC. A relação LF/HF foi de 2,7 na DMD e de 0,7 no controle (p = 0,002). Conclusões: Nos participantes com DMD, as ondas R proeminentes em V1 e alterações nas regiões inferior/lateral alta ocorreram em quase 30% dos casos. Houve menor tônus vagal sem influência das variáveis idade, fração de ejeção, dispersão do QT e tratamento. Apesar do aumento da FC, não houve resposta adequada da VFC com a mudança de posição.


Abstract Background: Duchenne Muscular Dystrophy (DMD) is a rare inherited neuromuscular disease. At first, cardiac involvement may be asymptomatic. Therefore, assessing patients using non-invasive methods can help detect any changes. Objectives: Analyze the electrocardiogram (ECG) test and heart rate variability (HRV) of the DMD group and compare the information with that of the age-matched control group. Methods: A prospective study with 27 male patients with DMD (11.9 years old), who underwent clinical evaluation, ECG, echocardiogram, and Holter monitoring. ECG (200% increase) was assessed by two independent observers. HRV was measured over time (24 h) and in the frequency domain, in the supine and sitting positions. The healthy group consisted of nine patients (11.0 years old). A value of p < 0.05 was considered statistically significant. Results: The mean ejection fraction (EF) was 60% (34 to 71%). The Kappa coefficient for ECG measurements ranged from 0.64 to 1.00. An increase in the R/S ratio in V1 was observed in 25.9% of the subjects, pathological Q wave in 29.6%, and fragmented QRS in 22.2% in inferior/high lateral regions, with a negative correlation with EF (p = 0.006). There was low HRV, without the influence of any variable, including treatment. With the change in position, there was an increase in HR (p = 0.004), but there was no change in HRV. The LF/HF ratio was 2.7 in the DMD group and 0.7 in the control group (p = 0.002). Conclusions: In DMD subjects, prominent R waves in V1 and changes in the inferior/high lateral regions occurred in almost 30% of the cases. Lower vagal tone was observed without the influence of the variables age, ejection fraction, QT dispersion, and treatment. Despite the increase in HR, there was no adequate HRV response to the change in position.

18.
Arq. bras. cardiol ; Arq. bras. cardiol;121(2): e20230653, 2024. tab, graf
Article de Portugais | LILACS-Express | LILACS | ID: biblio-1557012

RÉSUMÉ

Resumo Fundamento: As ferramentas de telecardiologia são estratégias valiosas para melhorar a estratificação de risco. Objetivo: Objetivamos avaliar a acurácia da tele-eletrocardiografia (ECG) para predizer anormalidades no ecocardiograma de rastreamento na atenção primária. Métodos: Em 17 meses, 6 profissionais de saúde em 16 unidades de atenção primária foram treinados em protocolos simplificados de ecocardiografia portátil. Tele-ECGs foram registrados para diagnóstico final por um cardiologista. Pacientes consentidos com anormalidades maiores no ECG pelo código de Minnesota e uma amostra 1:5 de indivíduos normais foram submetidos a um questionário clínico e ecocardiograma de rastreamento interpretado remotamente. A doença cardíaca grave foi definida como doença valvular moderada/grave, disfunção/hipertrofia ventricular, derrame pericárdico ou anormalidade da motilidade. A associação entre alterações maiores do ECG e anormalidades ecocardiográficas foi avaliada por regressão logística da seguinte forma: 1) modelo não ajustado; 2) modelo 1 ajustado por idade/sexo; 3) modelo 2 mais fatores de risco (hipertensão/diabetes); 4) modelo 3 mais história de doença cardiovascular (Chagas/cardiopatia reumática/cardiopatia isquêmica/AVC/insuficiência cardíaca). Foram considerados significativos valores de p < 0,05. Resultados: No total, 1.411 pacientes realizaram ecocardiograma, sendo 1.149 (81%) com anormalidades maiores no ECG. A idade mediana foi de 67 anos (intervalo interquartil de 60 a 74) e 51,4% eram do sexo masculino. As anormalidades maiores no ECG se associaram a uma chance 2,4 vezes maior de doença cardíaca grave no ecocardiograma de rastreamento na análise bivariada (OR = 2,42 [IC 95% 1,76 a 3,39]) e permaneceram significativas (p < 0,001) após ajustes no modelo 2 (OR = 2,57 [IC 95% 1,84 a 3,65]), modelo 3 (OR = 2,52 [IC 95% 1,80 a 3,58]) e modelo 4 (OR = 2,23 [IC 95% 1,59 a 3,19]). Idade, sexo masculino, insuficiência cardíaca e doença cardíaca isquêmica também foram preditores independentes de doença cardíaca grave no ecocardiograma. Conclusões: As anormalidades do tele-ECG aumentaram a probabilidade de doença cardíaca grave no ecocardiograma de rastreamento, mesmo após ajustes para variáveis demográficas e clínicas.


Abstract Background: Tele-cardiology tools are valuable strategies to improve risk stratification. Objective: We aimed to evaluate the accuracy of tele-electrocardiography (ECG) to predict abnormalities in screening echocardiography (echo) in primary care (PC). Methods: In 17 months, 6 health providers at 16 PC units were trained on simplified handheld echo protocols. Tele-ECGs were recorded for final diagnosis by a cardiologist. Consented patients with major ECG abnormalities by the Minnesota code, and a 1:5 sample of normal individuals underwent clinical questionnaire and screening echo interpreted remotely. Major heart disease was defined as moderate/severe valve disease, ventricular dysfunction/hypertrophy, pericardial effusion, or wall-motion abnormalities. Association between major ECG and echo abnormalities was assessed by logistic regression as follows: 1) unadjusted model; 2) model 1 adjusted for age/sex; 3) model 2 plus risk factors (hypertension/diabetes); 4) model 3 plus history of cardiovascular disease (Chagas/rheumatic heart disease/ischemic heart disease/stroke/heart failure). P-values < 0.05 were considered significant. Results: A total 1,411 patients underwent echo; 1,149 (81%) had major ECG abnormalities. Median age was 67 (IQR 60 to 74) years, and 51.4% were male. Major ECG abnormalities were associated with a 2.4-fold chance of major heart disease on echo in bivariate analysis (OR = 2.42 [95% CI 1.76 to 3.39]), and remained significant after adjustments in models (p < 0.001) 2 (OR = 2.57 [95% CI 1.84 to 3.65]), model 3 (OR = 2.52 [95% CI 1.80 to3.58]), and model 4 (OR = 2.23 [95%CI 1.59 to 3.19]). Age, male sex, heart failure, and ischemic heart disease were also independent predictors of major heart disease on echo. Conclusions: Tele-ECG abnormalities increased the likelihood of major heart disease on screening echo, even after adjustments for demographic and clinical variables.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE