Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 354
Filtrer
1.
Neurosurg Rev ; 47(1): 307, 2024 Jul 09.
Article de Anglais | MEDLINE | ID: mdl-38980428

RÉSUMÉ

Vestibular schwannomas (VS) are benign intracranial tumors posing significant management challenges. This study aims to compare the outcomes of stereotactic radiosurgery (SRS) and watchful waiting (WW) in the management of newly diagnosed VS, integrating findings from both retrospective and the pioneering V-REX prospective trial. Adhering to PRISMA guidelines, a systematic review was conducted using MEDLINE, Embase, and Cochrane databases. Studies directly comparing SRS with WW for newly diagnosed VS were included. Primary outcomes focused on hearing preservation assessed through the AAO-HNS or Gardner-Robertson hearing classification scales and tumor progression, with secondary outcomes focusing on neurological symptoms, and the need for further treatment. Thirteen studies encompassing 1,635 patients (WW: 891; SRS: 744) were included.While no significant difference was found in serviceable hearing loss at last follow-up (RR = 1.51, [95%CI: 0.98, 2.32], p = 0.06), significant differences favoring WW were observed in pure tone audiometry (PTA) (MD = -13.51 [95%CI: -22.66, -4.37], p = 0.004) and word recognition score (WRS) (MD = 20.48 [95%CI: 9.72, 31.25], p = 0.0002). Analysis of tumor progression indicated no overall significant difference in risk between SRS and WW (RR = 0.40, [95%CI 0.07, 2.40], p = 0.32), but subgroup analysis suggested a lower risk with SRS in certain contexts. The need for further treatments favored SRS (RR = 0.24, [95%CI: 0.07, 0.74], p = 0.007). No significant differences were found in tinnitus and imbalance between the two groups. This comprehensive analysis suggests no marked difference in functional hearing preservation between SRS and WW in managing VS. However, untreated tumors commonly necessitate additional interventions. These findings highlight the need for individualized treatment decisions and underscore the importance of continued monitoring. The study advocates for further prospective trials to refine management strategies for VS.


Sujet(s)
Neurinome de l'acoustique , Radiochirurgie , Observation (surveillance clinique) , Humains , Neurinome de l'acoustique/thérapie , Radiochirurgie/méthodes , Résultat thérapeutique
2.
Article de Anglais | MEDLINE | ID: mdl-39045727

RÉSUMÉ

OBJECTIVE: Hearing loss is a common symptom associated with vestibular schwannoma (VS), either because of the tumor's effects on the cochlear nerve or due to active treatments such as surgery or stereotactic radiosurgery (SRS). Treatment decisions for VS are based on factors including tumor size, hearing status, patient symptoms, and institutional preference. The study aimed to investigate long-term auditory outcomes in VS patients undergoing active treatments with a hearing preservation intent. DATA SOURCES: A systematic literature review was conducted following Preferred Reporting Items for Systematic Reviews and Meta-Analyses guidelines, searching Scopus, Pubmed, and Web of Science databases from inception to January 2024. REVIEW METHODS: Studies meeting inclusion criteria, including a minimum 5-year follow-up and assessment of pre- and posttreatment hearing outcomes, were included. Pooled prevalence estimates for serviceable hearing after SRS and microsurgery were calculated using MetaXL software. Risk of bias assessment was performed with the Risk of Bias in Non-randomized Studies of Interventions tool. RESULTS: Nine studies met the inclusion criteria, with 356 patients included for analysis. The pooled prevalence of maintaining serviceable hearing after SRS at 10 years was 18.1% (95% confidence interval [CI]: 1.7%-43.3%), with wide prediction intervals indicating variability in outcomes. Microsurgery demonstrated a higher prevalence of maintaining long-term serviceable hearing, with a pooled estimate of 74.5% (95% CI: 63.5%-84.1%). CONCLUSION: This systematic review underscores the importance of long-term follow-up in evaluating auditory outcomes in VS treatment. Despite the biases inherent to pretreatment patients selection, hearing preservation microsurgery for sporadic VS removal demonstrated favorable and stable long-term serviceable hearing.

3.
J Clin Med ; 13(14)2024 Jul 19.
Article de Anglais | MEDLINE | ID: mdl-39064270

RÉSUMÉ

Background: Quick and appropriate diagnostics and the use of intraoperative monitoring (IM) of hearing during vestibular schwannoma (VS) resection increase the likelihood of hearing preservation. During surgery, various methods of IM can be used, i.e., auditory brainstem responses (ABRs), transtympanic electrocochleography (TT-ECochG), and direct cochlear nerve action potentials. The aim of the study was to evaluate the prognostic values of IM of hearing using ABR and TT-ECochG in predicting postoperative hearing preservation and to evaluate relationships between them during various stages of surgery. Methods: This retrospective study presents the pre- and postoperative audiological test results and IM of hearing records (TT-ECochG and ABR) in 75 (43 women, 32 men, aged 18-69) patients with diagnosed VS. Results: The preoperative pure tone average hearing threshold was 25.02 dB HL, while after VS resection, it worsened on average by 30.03 dB HL. According to the American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) Hearing Classification, before and after (pre/post) surgery, there were 47/24 patients in hearing class A, 9/8 in B, 2/1 in C, and 17/42 in D. In speech audiometry, the average preoperative speech discrimination score at an intensity of 60 dB SPL was 70.93%, and after VS resection, it worsened to 38.93%. The analysis of electrophysiological tests showed that before the tumor removal the I-V ABR interlatencies was 5.06 ms, and after VS resection, it was 6.43 ms. Conclusions: The study revealed correlations between worse postoperative hearing and changes in intraoperatively measured ABR and TT-ECochG. IM of hearing is very useful in predicting postoperative hearing in VS patients and increases the chance of postoperative hearing preservation in these patients.

4.
Article de Anglais | MEDLINE | ID: mdl-38977480

RÉSUMÉ

BACKGROUND: Preservation of intracochlear structures and residual hearing has become a major concern in modern cochlear implant. Consequently, many efforts have been made to minimize intraoperative trauma, especially while cochlear fenestration and electrode insertion. METHODS: Building on the core concept of "soft surgery", a modified approach, described as diving technique for cochlear implant electrode array insertion is proposed. Steps and technical points are presented with figures, video and review of relevant anatomy. CONCLUSIONS: This novel diving technique is operationally feasible and safe, promising to minimize intraoperative invasion and thus preserve residual hearing in cochlear implant.

5.
Article de Anglais | MEDLINE | ID: mdl-38977479

RÉSUMÉ

PURPOSE: The retrolabyrinthine approach is a surgical method designed to preserve hearing after surgery. When paired with intraoperative monitoring and an endoscope, this approach has demonstrated high rates of postoperative hearing preservation. However, the long-term prognosis of hearing preservation after utilizing this approach for vestibular schwannomas remains unexplored. This study aimed to examine the long-term outcomes of preserved hearing, providing insights into the suitability of the retrolabyrinthine approach for hearing preservation surgery. METHODS: This study included 34 patients with preserved hearing after vestibular schwannoma surgery using the retrolabyrinthine approach at a single center. Long-term hearing prognosis and requirement for additional interventions were retrospectively examined. RESULTS: Immediate after post-operative hearing preservation rate was 71.7%. Among the 34 patients with preserved hearing post-vestibular schwannoma surgery, four (11.8%) required additional interventions. Other patients experienced a gradual deterioration in their hearing status, with an approximate 10 dB decline during the 5-year follow-up; however, a serviceable hearing level persisted long after the surgery in these individuals. CONCLUSIONS: This study indicated the rationale for the retrolabyrinthine approach as a hearing preservation surgery for vestibular schwannomas, emphasizing its long-term hearing prognosis.

6.
Audiol Neurootol ; : 1-11, 2024 Jul 18.
Article de Anglais | MEDLINE | ID: mdl-38981457

RÉSUMÉ

INTRODUCTION: Preservation of residual hearing after cochlear implantation remains challenging. There are several approaches to preserve residual hearing, but the configuration of the implant electrode array seems to play a major role. Lateral wall electrode arrays are seemingly more favorable in this context. To date, there are no experimental data available which correlate the spatial electrode position in the scala tympani with the extent of hearing preservation. METHODS: Based on micro-computed tomography (µCT) imaging data, this study analyses the exact position of a pure silicone electrode array inserted into the cochlea of four guinea pigs. Array position data were correlated with the extent of hearing loss after implantation, measured using auditory brainstem measurements in the frequency range of the area occupied by the electrode array area as well as apical to the array. RESULTS: The use of pure silicone arrays without electrodes resulted in artifact-free, high-resolution µCT images that allowed precise determination of the arrays' positions within the scala tympani. The electrode arrays' locations ranged from peri-modiolar to an anti-modiolar. These revealed a correlation of a lower postoperative hearing loss with a higher spatial proximity to the lateral wall. This correlation was found in the low-frequency range only. A significant correlation between the inter-individual differences in the diameter of the scala tympani and the postoperative hearing loss could not be observed. CONCLUSION: This study demonstrates the importance of the intra-cochlear electrode array's position for the preservation of residual hearing. The advantage of such an electrode array's position approximated to the lateral wall suggests, at least for this type of electrode array applied in the guinea pig, it would be advantageous in the preservation of residual hearing for the apical part of the cochlea, beyond the area occupied by the electrode array.

7.
J Neurooncol ; 169(3): 591-599, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-39073686

RÉSUMÉ

PURPOSE: Limited data provides guidance on the management of vestibular schwannomas (VSs) that have progressed despite primary Gamma Knife radiosurgery (GKRS). The present article reports our long-term experience after repeat GKRS for VS with sustained progression after solely primary GKRS management. METHODS: A retrospective review of 1997 patients managed between 1987 and 2023 was conducted. Eighteen patients had sustained tumor progression after primary GKRS and underwent repeat GKRS. The median repeat GKRS margin dose was 11 Gy (IQR: 11-12), the median tumor volume was 2.0 cc (IQR: 1.3-6.3), and the median cochlear dose in patients with preserved hearing was 3.9 Gy (IQR: 3-4.1). The median time between initial and repeat GKRS was 65 months (IQR: 38-118). RESULTS: The median follow-up was 70 months (IQR: 23-101). After repeat GKRS, two patients had further tumor progression at 4 and 21 months and required partial resection of their tumors. The 10-year actuarial tumor control rate after repeat GKRS was 88%. Facial nerve function was preserved in 13 patients who had House-Brackmann grade 1 or 2 function at the time of repeat GKRS. Two patients with serviceable hearing preservation (Gardner-Robertson grade 1 or 2) at repeat GKRS retained that function afterwards. In patients with tinnitus, vestibular dysfunction, and trigeminal neuropathy, symptoms remained stable or improved for 16/16 patients, 12/15 patients, and 10/12 patients, respectively. One patient developed facial twitching in the absence of tumor growth 21 months after repeat GKRS. CONCLUSIONS: Repeat GKRS effectively controlled tumor growth and preserved cranial nerve outcomes in most patients whose VS had sustained progression after initial primary radiosurgery.


Sujet(s)
Évolution de la maladie , Neurinome de l'acoustique , Radiochirurgie , Humains , Radiochirurgie/méthodes , Radiochirurgie/effets indésirables , Neurinome de l'acoustique/radiothérapie , Neurinome de l'acoustique/chirurgie , Neurinome de l'acoustique/anatomopathologie , Mâle , Femelle , Adulte d'âge moyen , Études rétrospectives , Sujet âgé , Adulte , Études de suivi , Résultat thérapeutique , Réintervention
8.
J Neurosurg ; : 1-10, 2024 Jun 28.
Article de Anglais | MEDLINE | ID: mdl-38941638

RÉSUMÉ

OBJECTIVE: Advancements in microsurgical technique and technology continue to improve outcomes in patients with skull base tumor. The primary cranial nerve eight monitoring systems used in hearing preservation surgery for vestibular schwannomas (VSs) are direct cranial nerve eight monitoring (DCNEM) and auditory brainstem response (ABR), although current guidelines are unable to definitively recommend one over the other due to limited literature on the topic. Thus, further research is needed to determine the utility of DCNEM and ABR. The authors performed a retrospective cohort study and created an interactive model that compares hearing preservation outcomes based on tumor size in patients receiving ABR+DCNEM and ABR-only monitoring. METHODS: Twenty-eight patients received ABR+DCNEM and 72 patients received ABR-only monitoring during VS hearing preservation surgery at a single tertiary academic medical center between January 2008 and November 2022. Inclusion criteria consisted of adult patients with a preoperative American Academy of Otolaryngology-Head and Neck Surgery (AAO-HNS) hearing classification of A or B. Tumor size was measured as the maximal medial to lateral length, including the internal auditory canal component. RESULTS: Overall hearing preservation (word recognition score [WRS] > 0%) was achieved in 31 patients with ABR-only monitoring (43.1%) and in 18 patients with ABR+DCNEM (64.3%). Serviceable hearing preservation (AAO-HNS class A or B) was attained in 19 patients with ABR-only monitoring (26.4%) and in 11 patients with ABR+DCNEM (39.3%). There was no difference in overall hearing preservation between the two groups (p = 0.13). Change in tumor size was not associated with the odds of serviceable hearing preservation for the ABR-only group (p = 0.89); however, for ABR+DCNEM, there was some indication of an interaction between tumor size and the association of ABR+DCNEM versus ABR-only monitoring, with the odds of serviceable hearing preservation at p = 0.089. Furthermore, with ABR+DCNEM, every 0.5-cm increase in tumor size was associated with a decreased odds of serviceable hearing preservation on multivariable analysis (p = 0.05). For both overall and serviceable hearing preservation, a worse preoperative AAO-HNS classification was associated with a decreased odds of preservation (OR 0.43, 95% CI 0.19-0.97, p = 0.042; OR 0.17, 95% CI 0.053-0.55, p = 0.0031, respectively). CONCLUSIONS: The result of this interactive model study proposes that there may be a higher chance of hearing preservation when using ABR+DCNEM rather than ABR alone for smaller tumors, with that relationship reversing as tumor size increases.

9.
Sensors (Basel) ; 24(11)2024 May 22.
Article de Anglais | MEDLINE | ID: mdl-38894099

RÉSUMÉ

Cochlear implants are crucial for addressing severe-to-profound hearing loss, with the success of the procedure requiring careful electrode placement. This scoping review synthesizes the findings from 125 studies examining the factors influencing insertion forces (IFs) and intracochlear pressure (IP), which are crucial for optimizing implantation techniques and enhancing patient outcomes. The review highlights the impact of variables, including insertion depth, speed, and the use of robotic assistance on IFs and IP. Results indicate that higher insertion speeds generally increase IFs and IP in artificial models, a pattern not consistently observed in cadaveric studies due to variations in methodology and sample size. The study also explores the observed minimal impact of robotic assistance on reducing IFs compared to manual methods. Importantly, this review underscores the need for a standardized approach in cochlear implant research to address inconsistencies and improve clinical practices aimed at preserving hearing during implantation.


Sujet(s)
Implantation cochléaire , Implants cochléaires , Humains , Implantation cochléaire/méthodes , Pression , Cochlée/chirurgie , Cochlée/physiologie , Interventions chirurgicales robotisées/méthodes , Robotique/méthodes , Perte d'audition/chirurgie , Perte d'audition/physiopathologie
10.
Trends Hear ; 28: 23312165241252240, 2024.
Article de Anglais | MEDLINE | ID: mdl-38715410

RÉSUMÉ

In recent years, tools for early detection of irreversible trauma to the basilar membrane during hearing preservation cochlear implant (CI) surgery were established in several clinics. A link with the degree of postoperative hearing preservation in patients was investigated, but patient populations were usually small. Therefore, this study's aim was to analyze data from intraoperative extracochlear electrocochleography (ECochG) recordings for a larger group.During hearing preservation CI surgery, extracochlear recordings were made before, during, and after CI electrode insertion using a cotton wick electrode placed at the promontory. Before and after insertion, amplitudes and stimulus response thresholds were recorded at 250, 500, and 1000 Hz. During insertion, response amplitudes were recorded at one frequency and one stimulus level. Data from 121 patient ears were analyzed.The key benefit of extracochlear recordings is that they can be performed before, during, and after CI electrode insertion. However, extracochlear ECochG threshold changes before and after CI insertion were relatively small and did not independently correlate well with hearing preservation, although at 250 Hz they added some significant information. Some tendencies-although no significant relationships-were detected between amplitude behavior and hearing preservation. Rising amplitudes seem favorable and falling amplitudes disadvantageous, but constant amplitudes do not appear to allow stringent predictions.Extracochlear ECochG measurements seem to only partially realize expected benefits. The questions now are: do gains justify the effort, and do other procedures or possible combinations lead to greater benefits for patients?


Sujet(s)
Audiométrie électroencéphalographique , Seuil auditif , Cochlée , Implantation cochléaire , Implants cochléaires , Ouïe , Humains , Audiométrie électroencéphalographique/méthodes , Études rétrospectives , Implantation cochléaire/instrumentation , Femelle , Adulte d'âge moyen , Mâle , Sujet âgé , Adulte , Ouïe/physiologie , Cochlée/chirurgie , Cochlée/physiopathologie , Résultat thérapeutique , Adolescent , Valeur prédictive des tests , Jeune adulte , Enfant , Audiométrie tonale , Sujet âgé de 80 ans ou plus , Enfant d'âge préscolaire , Perte d'audition/diagnostic , Perte d'audition/physiopathologie , Perte d'audition/chirurgie , Perte d'audition/rééducation et réadaptation
11.
Trends Hear ; 28: 23312165241248973, 2024.
Article de Anglais | MEDLINE | ID: mdl-38717441

RÉSUMÉ

To preserve residual hearing during cochlear implant (CI) surgery it is desirable to use intraoperative monitoring of inner ear function (cochlear monitoring). A promising method is electrocochleography (ECochG). Within this project the relations between intracochlear ECochG recordings, position of the recording contact in the cochlea with respect to anatomy and frequency and preservation of residual hearing were investigated. The aim was to better understand the changes in ECochG signals and whether these are due to the electrode position in the cochlea or to trauma generated during insertion. During and after insertion of hearing preservation electrodes, intraoperative ECochG recordings were performed using the CI electrode (MED-EL). During insertion, the recordings were performed at discrete insertion steps on electrode contact 1. After insertion as well as postoperatively the recordings were performed at different electrode contacts. The electrode location in the cochlea during insertion was estimated by mathematical models using preoperative clinical imaging, the postoperative location was measured using postoperative clinical imaging. The recordings were analyzed from six adult CI recipients. In the four patients with good residual hearing in the low frequencies the signal amplitude rose with largest amplitudes being recorded closest to the generators of the stimulation frequency, while in both cases with severe pantonal hearing losses the amplitude initially rose and then dropped. This might be due to various reasons as discussed in the following. Our results indicate that this approach can provide valuable information for the interpretation of intracochlearly recorded ECochG signals.


Sujet(s)
Audiométrie électroencéphalographique , Cochlée , Implantation cochléaire , Implants cochléaires , Humains , Cochlée/chirurgie , Cochlée/physiologie , Cochlée/physiopathologie , Implantation cochléaire/instrumentation , Implantation cochléaire/méthodes , Audiométrie électroencéphalographique/méthodes , Adulte d'âge moyen , Sujet âgé , Mâle , Femelle , Ouïe/physiologie , Adulte , Résultat thérapeutique , Valeur prédictive des tests , Stimulation électrique , Personnes malentendantes/rééducation et réadaptation , Personnes malentendantes/psychologie , Seuil auditif/physiologie
12.
Front Neurol ; 15: 1400455, 2024.
Article de Anglais | MEDLINE | ID: mdl-38711559

RÉSUMÉ

Purpose: The significance of atraumatic electrode array (EA) insertion in cochlear implant (CI) surgery is widely acknowledged, with consensus that forces due to EA insertion are directly correlated with insertion trauma. Unfortunately, the manual perception of these forces through haptic feedback is inherently limited, and techniques for in vivo force measurements to monitor the insertion are not yet available. Addressing this gap, we developed of a force-sensitive insertion tool capable of capturing real-time insertion forces during standard CI surgery. Methods: This paper describes the tool and its pioneering application in a clinical setting and reports initial findings from an ongoing clinical study. Data and experiences from five patients have been evaluated so far, including force profiles of four patients. Results: The initial intraoperative experiences are promising, with successful integration into the conventional workflow. Feasibility of in vivo insertion force measurement and practicability of the tool's intraoperative use could be demonstrated. The recorded in vivo insertion forces show the expected rise with increasing insertion depth. Forces at the end of insertion range from 17.2 mN to 43.6 mN, while maximal peak forces were observed in the range from 44.8 mN to 102.4 mN. Conclusion: We hypothesize that this novel method holds the potential to assist surgeons in monitoring the insertion forces and, thus, minimizing insertion trauma and ensuring better preservation of residual hearing. Future data recording with this tool can form the basis of ongoing research into the causes of insertion trauma, paving the way for new and improved prevention strategies.

13.
Cureus ; 16(4): e58269, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38752103

RÉSUMÉ

When pharmacological treatments are inadequate, facial nerve paralysis from various etiologies, including Bell's palsy, Hunt syndrome, and trauma, often requires surgical intervention. Facial nerve decompression surgery aims to relieve nerve compression and restore function, with preserving hearing function, especially in pediatric cases, being crucial. Conventional methods, like the transmastoid approach, risk affecting auditory function due to ossicle manipulation. Herein, we describe the case of a 12-year-old boy with left facial palsy diagnosed with zoster sine herpete (ZSH) syndrome. Despite medical treatment, the patient's condition did not improve, prompting facial nerve decompression surgery. Employing the intact transmastoid ossicle (ITO) swaying technique, we minimized ossicular manipulation, preserving auditory function while effectively achieving facial nerve decompression. The patient demonstrated improvement postoperatively in auditory and facial nerve functions. Furthermore, audiometric assessments demonstrated no substantial deterioration in hearing thresholds, and the facial nerve function improved from Grade V to Grade II on the House-Brackmann scale. The ITO technique provides a less invasive alternative compared to conventional approaches, lowering the chance of the ossicular chain and the risk of postoperative hearing loss. This case highlights the significance of customized surgical approaches in pediatric facial nerve decompression surgery, resulting in improved patient outcomes. Further research is required to validate the efficacy and safety of this method across various clinical contexts.

14.
Acta Otorhinolaryngol Ital ; 44(Suppl. 1): S86-S93, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38745520

RÉSUMÉ

The aim of this systematic review is to analyse the role of hearing preservation surgery for vestibular schwannoma. The complications and hearing outcomes of the single surgical techniques were investigated and compared with those of less invasive strategies, such as stereotactic radiotherapy and wait and scan policy. This systematic review and meta-analysis was performed according to the PRISMA guidelines. All included studies were published in English between 2000 and 2022. Literature data show that hearing preservation is achieved in less than 25% of patients after surgery and in approximately half of cases after stereotactic radiotherapy, even if data on long-term preservation are currently not available.


Sujet(s)
Neurinome de l'acoustique , Humains , Neurinome de l'acoustique/chirurgie , Perte d'audition/étiologie , Perte d'audition/prévention et contrôle
15.
Cochlear Implants Int ; : 1-9, 2024 May 13.
Article de Anglais | MEDLINE | ID: mdl-38738388

RÉSUMÉ

OBJECTIVES: Evaluate potential effects of calcium channel blockers (CCB) and bisphosphonates (BP) on residual hearing following cochlear implantation. METHODS: Medications of 303 adult hearing preservation (HP) candidates (low frequency pure tone average [LFPTA] of 125, 250, and 500 Hz ≤80 dB HL) were reviewed. Postimplantation LFPTA of patients taking CCBs and BPs were compared to controls matched by age and preimplantation LFPTA. RESULTS: Twenty-six HP candidates were taking a CCB (N = 14) or bisphosphonate (N = 12) at implantation. Median follow-up was 1.37 years (range 0.22-4.64y). Among subjects with initial HP, 29% (N = 2 of 7) CCB users compared to 50% (N = 2 of 4) controls subsequently lost residual hearing 3-6 months later (OR = 0.40, 95% CI = 0.04-4.32, p = 0.58). None of the four BP patients with initial HP experienced delayed loss compared to 50% (N = 2 of 4) controls with initial HP (OR = 0.00, 95% CI = 0.00-1.95, P = 0.43). Two CCB and one BP patients improved to a LFPTA <80 dB HL following initial unaided thresholds that suggested loss of residual hearing. DISCUSSION: There were no significant differences in the odds of delayed loss of residual hearing with CCBs or BPs. CONCLUSION: Further investigation into potential otoprotective adjuvants for maintaining residual hearing following initial successful hearing preservation is warranted, with larger cohorts and additional CCB/BP agents.

16.
J Clin Med ; 13(7)2024 Mar 27.
Article de Anglais | MEDLINE | ID: mdl-38610692

RÉSUMÉ

Background: In order to better understand the pathophysiology of surgically induced hearing loss after vestibular schwannoma (VS) surgery, we postoperatively analyzed the hearing status in a series of patients where hearing was at least partially preserved. Methods: Hearing was assessed through tonal audiometry, speech discrimination score, maximum word recognition score (dissyllabic word lists-MaxIS), otoacoustic emissions (OAEs), and auditory brainstem response (ABR). The magnetic resonance imaging (MRI) tumor characterization was also noted. Results: In a series of 24 patients operated on for VS over 5 years, depending on the results of this triple hearing exploration, we could identify, after surgery, patients with either a myelin alteration or partial damage to the acoustic fibers, others with a likely partial cochlear ischemia, and some with partial cochlear nerve ischemia. One case with persisting OAEs and no preoperative ABR recovered hearing and ABR after surgery. Long follow-up (73 ± 57 months) revealed a mean hearing loss of 30 ± 20 dB with a drastic drop of MaxIS. MRI revealed only 25% of fundus invasion. Conclusion: a precise analysis of hearing function, not only with classic audiometry but also with ABR and OEAs, allows for a better understanding of hearing damage in VS surgery.

17.
Article de Anglais | MEDLINE | ID: mdl-38630273

RÉSUMÉ

INTRODUCTION: Achieving a slow and smooth electrode array insertion is paramount for preserving structural and functional integrity during cochlear implantation. This controlled study evaluates the efficacy of a metronome-guided insertion technique in enhancing the smoothness and speed of electrode array insertions. METHODS: In a prospective cohort study, patients undergoing cochlear implant surgery between 2022 and 2023 with lateral wall electrode arrays were included. Metronome guidance was delivered through an acoustic signal via headphones during electrode array insertion in cochlear implantation and compared to a control group without metronome-guidance. RESULTS: In total, 37 cases were evaluated, including 25 conventional insertions and 12 metronome-guided insertions. The results indicate that metronome-guided insertions were significantly slower (- 0.46 mm/s; p < 0.001) without extending the overall procedure time. This can be attributed to fewer paused sections observed in the metronome-guided technique. Moreover, metronome-guided insertions exhibited superior performance in terms of insertion smoothness and a reduced number of re-gripping events. CONCLUSIONS: The findings support the recommendation for the systematic application of metronome guidance in the manual insertion of cochlear implant electrode arrays, emphasizing its potential to optimize surgical outcomes.

18.
Otolaryngol Head Neck Surg ; 171(2): 530-537, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38545636

RÉSUMÉ

OBJECTIVE: The objective was to determine the effects of older age on hearing preservation after cochlear implantation (CI), and whether steroids improve hearing preservation in older animals. We hypothesized greater hearing preservation would be observed in (1) young animals compared to older animals and (2) older animals receiving steroids compared to no steroids. The secondary objective was to assess levels of fibrosis utilizing optical coherence tomography (OCT). STUDY DESIGN: Experimental Animal Study. SETTING: Laboratory. METHODS: Three groups of guinea pigs: young (YCI; 8.5 ± 0.5 weeks; n = 10), old (OCI; 19.1 ± 1.0 months; n = 9) and old + steroids (OCI+S; 19.1 ± 1.0 months; n = 9) underwent CI. The OCI+S group received a steroid taper over 7 days starting 2 days before surgery to 4 days after. Auditory brainstem response (ABR) measurements were performed preoperatively and postoperatively. OCT imaging was performed to assess cochleae for extent of fibrotic tissue growth in the scala tympani. RESULTS: The YCI group had significantly better hearing preservation as measured by smaller increases in ABR thresholds [mean shift: 2.79 ± 0.66] compared to the OCI group [mean shift = 12.44 ± 5.6]. The OCI+S group had significantly better hearing preservation [2.66 ± 1.50] compared to the OCI group. No significant differences was seen in fibrosis across groups. CONCLUSIONS: Young animals and older animals that received steroids had better hearing after CI than older animals not given steroids, but hearing preservation was not correlated with the level of fibrosis assessed using OCT. This work is the first to investigate differences in hearing preservation by age in an animal model, and supports the protective effects of steroids on hearing preservation in older individuals.


Sujet(s)
Vieillissement , Cochlée , Implantation cochléaire , Tomographie par cohérence optique , Animaux , Cochons d'Inde , Cochlée/effets des médicaments et des substances chimiques , Vieillissement/physiologie , Potentiels évoqués auditifs du tronc cérébral/effets des médicaments et des substances chimiques , Glucocorticoïdes/pharmacologie , Modèles animaux de maladie humaine , Fibrose , Facteurs âges
19.
J Neurol Surg B Skull Base ; 85(2): 123-130, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38449586

RÉSUMÉ

Background Evidence on hearing outcome measures when assessing hearing preservation following stereotactic radiosurgery (SRS) for adults with vestibular schwannoma (VS) has not previously been collated in a structured review. Objective The objective of the present study was to perform a scoping review of the evidence regarding the choice of hearing outcomes and other methodological characteristics following SRS for adults with VS. Methods The protocol was registered in the International Platform of Registered Systematic Review and Meta-Analysis Protocols (INPLASY) and reported according to the Preferred Reporting Items for Systematic Review and Meta-Analyses extension guidelines for scoping reviews. A systematic search of five online databases revealed 1,591 studies, 247 of which met the inclusion criteria. Results The majority of studies ( n = 213, 86%) were retrospective cohort or case series with the remainder ( n = 34, 14%) prospective cohort. Pure-tone audiometry and speech intelligibility were included in 222 (90%) and 158 (64%) studies, respectively, often summarized within a classification scheme and lacking procedural details. Fifty-nine (24%) studies included self-report measures. The median duration of follow-up, when reported, was 43 months (interquartile range: 29, 4-150). Conclusion Evidence on hearing disability after SRS for VS is based on low-quality studies which are inherently susceptible to bias. This review has highlighted an urgent need for a randomized controlled trial assessing hearing outcomes in patients with VS managed with radiosurgery or radiological observation. Similarly, consensus and coproduction of a core outcome set to determine relevant hearing and communication outcome domains is required. This will ensure that patient priorities, including communication abilities in the presence of background noise and reduced participation restrictions, are addressed.

20.
Laryngoscope ; 134(8): 3458-3465, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38381055

RÉSUMÉ

OBJECTIVE: Cochlear implant surgery is guided by principles of atraumatic insertion as to protect the inner ear. Previous studies suggest the potential benefit of steroids in patients undergoing cochlear implantation (CI), although the optimal route of administration has yet to be determined. We aim to systematically review the human studies of hearing and vestibular function preservation in patients undergoing CI receiving perioperative steroids and to discuss their role. DATA SOURCES: Search performed in PubMed, EMBASE, and CENTRAL databases in December 2023. REVIEW METHODS: Studies comparing several methods of steroid delivery and conventional management for patients undergoing CI were identified. Primary outcomes included hearing and vestibular function preservation. Secondary outcomes included reported adverse events, routes of steroid administration, and the presence of a control group without steroid administration. RESULTS: A total of 15 studies (N = 659) met inclusion criteria. Methodology, doses, route of steroid administration, and follow-up duration differed between most studies. Audiometric, vestibular, and hearing preservation (HP) results were inconsistent. In 12 studies, perioperative steroids were associated with either increased HP or vestibular function preservation. Only two studies reported adverse events related to oral corticosteroid therapy. CONCLUSIONS: There is a tendency for perioperative steroids to have a positive impact, at least in the short term, on hearing and vestibular function preservation in CI. Topical corticosteroid therapy appears to have a superior risk-benefit profile. There is a need for future carefully designed randomized controlled trials to determine the ideal route of steroid administration and its real impact in the long term. Laryngoscope, 134:3458-3465, 2024.


Sujet(s)
Implantation cochléaire , Ouïe , Labyrinthe vestibulaire , Humains , Implantation cochléaire/effets indésirables , Implantation cochléaire/méthodes , Glucocorticoïdes/administration et posologie , Glucocorticoïdes/effets indésirables , Ouïe/effets des médicaments et des substances chimiques , Perte d'audition/prévention et contrôle , Perte d'audition/chirurgie , Labyrinthe vestibulaire/effets des médicaments et des substances chimiques
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE