1.
Methods Protoc ; 7(3)2024 May 23.
Article de Anglais | MEDLINE | ID: mdl-38921825

RÉSUMÉ

Auditory impairment stands as a pervasive global issue, exerting significant effects on individuals' daily functioning and interpersonal engagements. Cochlear implants (CIs) have risen as a cutting-edge solution for severe to profound hearing loss, directly stimulating the auditory nerve with electrical signals. The success of CI procedures hinges on precise pre-operative planning and post-operative evaluation, highlighting the significance of advanced three-dimensional (3D) inner ear reconstruction software. Accurate pre-operative imaging is vital for identifying anatomical landmarks and assessing cochlear deformities. Tools like 3D Slicer, Amira and OTOPLAN provide detailed depictions of cochlear anatomy, aiding surgeons in simulating implantation scenarios and refining surgical approaches. Post-operative scans play a crucial role in detecting complications and ensuring CI longevity. Despite technological advancements, challenges such as standardization and optimization persist. This review explores the role of 3D inner ear reconstruction software in patient selection, surgical planning, and post-operative assessment, tracing its evolution and emphasizing features like image segmentation and virtual simulation. It addresses software limitations and proposes solutions, advocating for their integration into clinical practice. Ultimately, this review underscores the impact of 3D inner ear reconstruction software on cochlear implantation, connecting innovation with precision medicine.

2.
Audiol Neurootol ; 29(3): 239-245, 2024.
Article de Anglais | MEDLINE | ID: mdl-38190811

RÉSUMÉ

OBJECTIVE: The purpose of this study was to compare the originally applied frequency allocation of cochlear implant electrodes assigned by default at the time of activation with a more recent frequency allocation that is anatomy-based by a software called OTOPLAN®. Based on a computed tomography scan of the temporal bone, this software calculates the position of each electrode in the cochlea and its corresponding tonotopic frequency. We also evaluated whether patients with a significant mismatch between these two allocations present poorer speech intelligibility. MATERIALS AND METHODS: Patients who underwent cochlear implantation from 2016 to 2021 at the University Hospital of Liege were included in this retrospective study. We used OTOPLAN® to calculate the tonotopic frequency allocation of each electrode according to its exact position in the cochlear duct. This anatomical frequency mapping was compared with the default frequency mapping at the time of cochlear implant activation. Finally, we compared the mismatch with the patients' auditory performance, represented by the Auditory Capacity Index (ACI). RESULTS: Thirteen patients were included in the study. All patients had a mismatch between the two frequency maps, to a variable extent (200 Hz-1,100 Hz). Frequency shift was significantly inversely correlated with ACI and with the time needed to improve speech intelligibility. CONCLUSION: Our primary results show that patients with a larger mismatch between default frequency mapping and anatomically assigned frequency mapping experience poorer hearing performance and slower adaptation to a cochlear implant.


Sujet(s)
Implantation cochléaire , Implants cochléaires , Logiciel , Humains , Mâle , Femelle , Études rétrospectives , Adulte d'âge moyen , Implantation cochléaire/méthodes , Sujet âgé , Adulte , Perception de la parole/physiologie , Tomodensitométrie , Os temporal/imagerie diagnostique , Os temporal/chirurgie , Intelligibilité de la parole , Ouïe/physiologie , Cochlée/imagerie diagnostique , Cochlée/chirurgie , Sujet âgé de 80 ans ou plus
3.
Audiol Res ; 13(5): 791-801, 2023 Oct 18.
Article de Anglais | MEDLINE | ID: mdl-37887851

RÉSUMÉ

The cochlear implant (CI) is a widely accepted option in patients with severe to profound hearing loss receiving limited benefit from traditional hearing aids. CI surgery uses a default setting for frequency allocation aiming to reproduce tonotopicity, thus mimicking the normal cochlea. One emerging instrument that may substantially help the surgeon before, during, and after the surgery is a surgical planning software product developed in collaboration by CASCINATION AG (Bern, Switzerland) and MED-EL (Innsbruck Austria). The aim of this narrative review is to present an overview of the main features of this otological planning software, called OTOPLAN®. The literature was searched on the PubMed and Web of Science databases. The search terms used were "OTOPLAN", "cochlear planning software" "three-dimensional imaging", "3D segmentation", and "cochlear implant" combined into different queries. This strategy yielded 52 publications, and a total of 31 studies were included. The review of the literature revealed that OTOPLAN is a useful tool for otologists and audiologists as it improves preoperative surgical planning both in adults and in children, guides the intraoperative procedure and allows postoperative evaluation of the CI.

4.
Cureus ; 15(10): e46417, 2023 Oct.
Article de Anglais | MEDLINE | ID: mdl-37794885

RÉSUMÉ

Objectives Preoperative image analysis of skin flap thickness and determining the required magnet strength are important in the management of CI surgery. The primary aim of this study is to analyze the application of OTOPLAN®, a tablet-based otological preplanning tool, in assessing skin flap thickness. The secondary aim was to determine if there is any correlation between the skin flap thickness and the selected magnet strength. Methods Fifty-seven computer tomography (CT) image datasets of temporal bones of cochlear implant (CI) patients were collected. CE marked OTOPLAN® planning otology software was used to load the patient's preoperative images for measuring the skin flap thickness in both axial and coronal views. To standardize the skin flap thickness measurement, the top of the pinna on the side of implantation was taken as the measurement point. Results The mean age of the patients was 7.98 ± 1.54 years. The body mass index (BMI) was not considered in this study. The average skin flap thickness was 4.5 ± 1.2 mm (range: 2-7 mm). The inter-rater reliability test revealed strong agreement between the two reviewers (Cronbach's alpha = 0.90). The majority of the patients were fitted with a magnet strength of 3. A statistically significant positive correlation was observed between the skin flap thickness and the age of the patients (r = 0.69, p = 0.002). Also, between the skin flap thickness and the magnet strength, a strong positive correlation was observed (r = 0.82, p < 0.0001). Conclusions OTOPLAN® is a reliable tool in the measurement of skin flap thickness with little effort. The age and the magnet strength were positively correlated with the skin flap thickness.

5.
J Pers Med ; 13(8)2023 Aug 20.
Article de Anglais | MEDLINE | ID: mdl-37623526

RÉSUMÉ

Otoplan is a surgical planning software designed to assist with cochlear implant surgery. One of its outputs is a recommendation of electrode array type based on imaging parameters. In this retrospective study, we evaluated the differences in auditory outcomes between patients who were implanted with arrays corresponding to those recommended by the Otoplan software versus those in which the array selection differed from the Otoplan recommendation. Pre-operative CT images from 114 patients were imported into the software, and array recommendations were generated. These were compared to the arrays which had actually been implanted during surgery, both in terms of array type and length. As recommended, 47% of patients received the same array, 34% received a shorter array, and 18% received a longer array. For reasons relating to structure and hearing preservation, 83% received the more flexible arrays. Those who received stiffer arrays had cochlear malformations or ossification. A negative, although non-statistically significant correlation was observed between the CNC scores at 12 months and the absolute value of the difference between recommended array and implanted array. In conclusion, clinicians may be slightly biased toward shorter electrode arrays due to their perceived greater ability to achieve full insertion. Using 3D imaging during the pre-operative planning may improve clinicians' confidence to implant longer electrode arrays, where appropriate, to achieve optimum hearing outcomes.

6.
J Pers Med ; 13(5)2023 May 08.
Article de Anglais | MEDLINE | ID: mdl-37240975

RÉSUMÉ

INTRODUCTION: Electrode length selection based on case-related cochlear parameters is becoming a standard pre-operative step for cochlear implantation. The manual measurement of the parameters is often time-consuming and may lead to inconsistencies. Our work aimed to evaluate a novel, automatic measurement method. MATERIALS AND METHODS: A retrospective evaluation of pre-operative HRCT images of 109 ears (56 patients) was conducted, using a development version of the OTOPLAN® software. Inter-rater (intraclass) reliability and execution time were assessed for manual (surgeons R1 and R2) vs. automatic (AUTO) results. The analysis included A-Value (Diameter), B-Value (Width), H-Value (Height), and CDLOC-length (Cochlear Duct Length at Organ of Corti/Basilar membrane). RESULTS: The measurement time was reduced from approximately 7 min ± 2 (min) (manual) to 1 min (AUTO). Cochlear parameters in mm (mean ± SD) for R1, R2 and AUTO, respectively, were A-value: 9.00 ± 0.40, 8.98 ± 0.40 and 9.16 ± 0.36; B-value: 6.81 ± 0.34, 6.71 ± 0.35 and 6.70 ± 0.40; H-value: 3.98 ± 0.25, 3.85 ± 0.25 and 3.76 ± 0.22; and the mean CDLoc-length: 35.64 ± 1.70, 35.20 ± 1.71 and 35.47 ± 1.87. AUTO CDLOC measurements were not significantly different compared to R1 and R2 (H0: Rx CDLOC = AUTO CDLOC: p = 0.831, p = 0.242, respectively), and the calculated intraclass correlation coefficient (ICC) for CDLOC was 0.9 (95% CI: 0.85, 0.932) for R1 vs. AUTO; 0.90 (95% CI: 0.85, 0.932) for R2 vs. AUTO; and 0.893 (95% CI: 0.809, 0.935) for R1 vs. R2. CONCLUSIONS: We observed excellent inter-rater reliability, a high agreement of outcomes, and reduced execution time using the AUTO method.

7.
Cochlear Implants Int ; 24(3): 144-154, 2023 05.
Article de Anglais | MEDLINE | ID: mdl-36617441

RÉSUMÉ

OBJECTIVES: In cochlear implantation, preoperative prediction of electrode position has recently gained increasing attention. Currently, planning is usually done by multislice CT (MSCT). However, flat-panel volume CT (fpVCT) and its secondary reconstructions (fpVCTSECO) allow for more precise visualization of the cochlea. Combined with a newly developed otological planning software, the position of every single contact can be effectively predicted. In this study it was investigated how accurately radiological prediction forecasts the postoperative electrode localization and whether higher image resolution is advantageous. METHODS: Utilizing otological planning software (OTOPLAN®) and different clinical imaging modalities (MSCT, fpVCT and fpVCTSECO) the electrode localization [angular insertion depth (AID)] and respective contact frequencies were predicted preoperatively and examined postoperatively. Furthermore, inter-electrode-distance (IED) and inter-electrode-frequency difference (IEFD) were evaluated postoperatively. RESULTS: Measurements revealed a preoperative overestimation of AID. Corresponding frequencies were also miscalculated. Determination of IED and IEFD revealed discrepancies at the transition from the basal to the middle turn and round window to the basal turn. All predictions and discrepancies were lowest when using fpVCTSECO. CONCLUSION: The postoperative electrode position can be predicted quite accurately using otological planning software. However, because of several potential misjudgments, high-resolution imaging, such as offered by fpVCTSECO, should be used pre- and postoperatively.


Sujet(s)
Implantation cochléaire , Implants cochléaires , Humains , Implantation cochléaire/méthodes , Cochlée/imagerie diagnostique , Cochlée/chirurgie , Tomodensitométrie à faisceau conique , Logiciel
8.
Indian J Otolaryngol Head Neck Surg ; 74(4): 575-581, 2022 Dec.
Article de Anglais | MEDLINE | ID: mdl-36514425

RÉSUMÉ

To study the postoperative visualisation of the electrode array insertion angle through transcanal Veria approach in both round window and cochleostomy techniques. Retrospective study. Tertiary care centre. 26 subjects aged 2-15 years implanted with a MED-EL STANDARD electrode array (31.5 mm) through Veria technique were selected. 16 had the electrode insertion through the round window, 10 through anteroinferior cochleostomy. DICOM files of postoperative computer tomography (CT) scans were collected and analysed using the OTOPLAN 3.0 software. Examined parameters were cochlear duct length, average angle of insertion depth. Pearson's Correlation Test was utilized for statistical analysis. Average cochlear duct length was 38.12 mm, ranging from 34.2 to 43 mm. Average angle of insertion depth was 666 degrees through round window insertion and 670 degrees through cochleostomy insertion. Pearson's correlation showed no significant difference in average angle of insertion depth between subjects with cochleostomy and round window insertion. Detailed study on the OTOPLAN software has established that there remains no difference between round window insertion or cochleostomy insertion when it comes to electrode array position and placement in the scala tympani. It is feasible to perform round window insertion and cochleostomy insertion through transcanal Veria approach as this technique provides good visualisation. Supplementary Information: The online version contains supplementary material available at 10.1007/s12070-022-03228-5.

9.
HNO ; 70(10): 769-777, 2022 Oct.
Article de Allemand | MEDLINE | ID: mdl-35970933

RÉSUMÉ

BACKGROUND: Cochlear duct length (CDL) is subject to significant individual variation. In the context of cochlear implantation, adapting the electrode array length to the CDL is of potential interest, as it has been associated with improvements in both speech recognition and sound quality. Using a tablet-based software package, it is possible to measure CDL at the level of the organ of Corti (CDLOC) to select appropriate electrode array lengths based on individual cochlear anatomy. OBJECTIVE: To identify effects of imaging modality and rater background on CDL estimates. METHODS: Magnetic resonance imaging (MRI) and flat-panel volume CT (fpVCT) scans of 10 patients (20 cochleae) were analyzed using the OTOPLAN software package (MED-EL, Innsbruck, Austria). Raters were an otorhinolaryngology (ORL) specialist, an ORL resident, and an audiologist. To analyze effects of rater background and imaging modality on CDL measurements, linear mixed models were constructed. RESULTS: Measurements showed mean CDLOC(fpVCT) = 36.69 ± 1.78 mm and CDLOC(MRI) = 36.81 ± 1.87 mm. Analyses indicated no significant effect of rater background (F(2, 105) = 0.84; p = 0.437) on CDL estimates. Imaging modality, on the other hand, significantly affected CDL (F (1, 105) = 20.70; p < 0.001), whereby estimates obtained using MRI were 0.89 mm larger than those obtained using fpVCT. CONCLUSION: No effect of rater background on CDL estimates could be identified, suggesting that comparable measurements could be obtained by personnel other than specially trained neurootologists. While imaging modality (fpVCT vs. MRI) did impact CDL results, the difference was small and of questionable clinical significance.


Sujet(s)
Implantation cochléaire , Implants cochléaires , Cochlée/imagerie diagnostique , Cochlée/chirurgie , Conduit cochléaire/anatomie et histologie , Conduit cochléaire/chirurgie , Implantation cochléaire/méthodes , Humains , Logiciel , Tomodensitométrie/méthodes
10.
Cochlear Implants Int ; 23(2): 59-69, 2022 Mar.
Article de Anglais | MEDLINE | ID: mdl-34590531

RÉSUMÉ

OBJECTIVE: To assess whether the pre-operative electrode to cochlear duct length ratio (ECDLR), is associated with post-operative speech recognition outcomes. STUDY DESIGN: A retrospective chart review study. SETTING: Tertiary referral center. PATIENTS: The study included sixty-one adult CI recipients with a pre-operative computed tomography scan and a speech recognition test 12 months after implantation. INTERVENTIONS: The average of two raters' cochlear duct length (CDL) measurements and the length of the recipient's cochlear implant electrode array formed the basis for the electrode-to-cochlear duct length ratio (ECLDR). Speech recognition tests were compared as a function of ECDLR and electrode array length itself. MAIN OUTCOME MEASURES: The relationship between ECDLR and percent correct on speech recognition tests. RESULTS: A second order polynomial regression relating ECDLR to percent correct on the CNC words speech recognition test was statistically significant, as was a fourth order polynomial regression for the AzBio Quiet test. In contrast, there was no statistically significant relationship between speech recognition scores and electrode array length. CONCLUSIONS: ECDLR values can be statistically associated to speech-recognition outcomes. However, these ECDLR values cannot be predicted by the electrode length alone, and must include a measure of CDL.


Sujet(s)
Implantation cochléaire , Implants cochléaires , Perception de la parole , Adulte , Conduit cochléaire , Implantation cochléaire/méthodes , Humains , Études rétrospectives , Parole , Résultat thérapeutique
11.
Eur Arch Otorhinolaryngol ; 279(4): 1851-1861, 2022 Apr.
Article de Anglais | MEDLINE | ID: mdl-34050805

RÉSUMÉ

PURPOSE: In cochlear implantation, thorough preoperative planning together with measurement of the cochlear duct length (CDL) assists in choosing the correct electrode length. For measuring the CDL, different techniques have been introduced in the past century along with the then available technology. A tablet-based software offers an easy and intuitive way to visualize and analyze the anatomy of the temporal bone, its proportions and measure the CDL. Therefore, we investigated the calculation technique of the CDL via a tablet-based software on our own cohort retrospectively. METHODS: One hundred and eight preoperative computed tomography scans of the temporal bone (slice thickness < 0.7 mm) of already implanted FLEX28™ and FLEXSOFT™ patients were found eligible for analysis with the OTOPLAN software. Measurements were performed by two trained investigators independently. CDL, angular insertion depth (AID), and cochlear coverage were calculated and compared between groups of electrode types, sex, sides, and age. RESULTS: Mean CDL was 36.2 ± 1.8 mm with significant differences between sex (female: 35.8 ± 0.3 mm; male: 36.5 ± 0.2 mm; p = 0.037), but none concerning side or age. Differences in mean AID (FLEX28: 525.4 ± 46.4°; FLEXSOFT: 615.4 ± 47.6°), and cochlear coverage (FLEX28: 63.9 ± 5.6%; FLEXSOFT: 75.8 ± 4.3%) were significant (p < 0.001). CONCLUSION: A broad range of CDL was observed with significant larger values in male, but no significant differences concerning side or age. Almost every cochlea was measured longer than 31.0 mm. Preoperative assessment aids in prevention of complications (incomplete insertion, kinking, tipfoldover), attempt of atraumatic insertion, and addressing individual necessities (hearing preservation, cochlear malformation). The preferred AID of 720° (two turns of the cochlea) was never reached, opening the discussion for the requirement of longer CI-electrodes versus a debatable audiological benefit for the patient in his/her everyday life.


Sujet(s)
Implantation cochléaire , Implants cochléaires , Cochlée/imagerie diagnostique , Cochlée/chirurgie , Conduit cochléaire , Implantation cochléaire/méthodes , Femelle , Humains , Mâle , Études rétrospectives , Logiciel , Os temporal/imagerie diagnostique , Os temporal/chirurgie
12.
Front Surg ; 8: 741401, 2021.
Article de Anglais | MEDLINE | ID: mdl-34820415

RÉSUMÉ

The HEARO cochlear implantation surgery aims to replace the conventional wide mastoidectomy approach with a minimally invasive direct cochlear access. The main advantage of the HEARO access would be that the trajectory accommodates the optimal and individualized insertion parameters such as type of cochlear access and trajectory angles into the cochlea. To investigate the quality of electrode insertion with the HEARO procedure, the insertion process was inspected under fluoroscopy in 16 human cadaver temporal bones. Prior to the insertion, the robotic middle and inner ear access were performed through the HEARO procedures. The status of the insertion was analyzed on the post-operative image with Siemens Artis Pheno (Siemens AG, Munich, Germany). The completion of the full HEARO procedure, including the robotic inner ear access and fluoroscopy electrode insertion, was possible in all 16 cases. It was possible to insert the electrode in all 16 cases through the drilled tunnel. However, one case in which the full cochlea was not visible on the post-operative image for analysis was excluded. The post-operative analysis of the electrode insertion showed an average insertion angle of 507°, which is equivalent to 1.4 turns of the cochlea, and minimal and maximal insertion angles were recorded as 373° (1 cochlear turn) and 645° (1.8 cochlear turn), respectively. The fluoroscopy inspection indicated no sign of complications during the insertion.

SÉLECTION CITATIONS