Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 5 de 5
Filtrer
Plus de filtres










Base de données
Gamme d'année
1.
Med Eng Phys ; 125: 104119, 2024 03.
Article de Anglais | MEDLINE | ID: mdl-38508799

RÉSUMÉ

OBJECTIVES: The cementless Oxford Unicompartmental Knee Replacement (OUKR) tibial component relies on an interference fit to achieve initial fixation. The behaviour at the implant-bone interface is not fully understood and hence modelling of implants using Finite Element (FE) software is challenging. With a goal of exploring alternative implant designs with lower fracture risk and adequate fixation, this study aims to investigate whether optimisation of FE model parameters could accurately reproduce experimental results of a pull-out test which assesses fixation. MATERIALS AND METHODS: Finite element models of implants with three methods of fixation (standard keel, small keel, and peg) in a bone analogue foam block were created, in which implants were modelled using an analytical rigid definition and the foam block was modelled as a homogenous linear isotropic material. The total interference and elastic slip were varied in these models and optimised by comparing simulated and experimental results of pull-out tests for two (standard and peg) implant geometries. Then the optimised interference and elastic slip were validated by comparing simulated and experimental data of a third (small keel) implant geometry. RESULTS: The optimisation of parameters established an interference of 0.16 mm and an elastic slip of 0.20 mm as most suitable for modelling the experimental force-displacement plots during pull-out. This combination of parameters accurately reproduced the experimental results of the small keel geometry. The maximum pull-out forces from the FE models were consistent with experimental data for each implant design. CONCLUSIONS: This study shows that experimental pull-out tests can be accurately modelled using adjusted interference values and non-linear friction and outlines a method for determining these parameters. This study demonstrates that complex problems in modelling implant behaviour can be addressed with relatively simple models. This can potentially lead to the development of implants with reduced risk of failure.


Sujet(s)
Arthroplastie prothétique de genou , Prothèse de genou , Analyse des éléments finis , Conception de prothèse , Tibia/chirurgie
2.
J Clin Med ; 12(4)2023 Feb 20.
Article de Anglais | MEDLINE | ID: mdl-36836231

RÉSUMÉ

The number of unicompartmental knee replacements (UKR) is increasing. Alongside various advantages, the revision rate of cemented UKR is higher compared to total knee arthroplasty (TKR). In contrast, cementless fixation shows reduced revision rates, compared to the cemented UKR. However, most of the recent literature is based on designer-dependent studies. In this retrospective, single-center cohort study, we investigated patients who underwent cementless Oxford UKR (OUKR) between 2012 and 2016 in our hospital with a minimum follow-up of five years. Clinical outcome was evaluated using the OKS, AKSS-O, AKSS-F, FFbH-OA, UCLA, SF-36, EQ-5D-3L, FJS, ROM, pain, and satisfaction measures. Survival analysis was performed with reoperation and revision as endpoints. We included 201 patients (216 knees) for clinical evaluation. All outcome parameters increased significantly from pre- to postoperative stages. The five-year survival rate was 96.1% for revision surgery and 94.9% for reoperation. The main reasons for revision were the progression of osteoarthritis, inlay dislocation, and tibial overstuffing. Two iatrogenic tibial fractures appeared. Cementless OUKR shows excellent clinical outcome and high survival rates after five years. The tibial plateau fracture in cementless UKR represents a serious complication and requires modification of the surgical technique.

3.
J Clin Med ; 9(5)2020 May 14.
Article de Anglais | MEDLINE | ID: mdl-32423118

RÉSUMÉ

(1) Background: Studies show several advantages of unicompartmental knee replacement (UKR) over total knee replacements (TKR), whereas registry based revision rates of UKR are significantly higher than for TKA. Registry data report lower revision rates for cementless UKR compared to cemented UKR. The aim of this study was to assess clinical and radiological results of cementless Oxford UKR (OUKR) in an independent cohort. (2) Methods: This retrospective cohort study examines a consecutive series of 228 cementless OUKR. Clinical outcome was measured using functional scores (Oxford Knee Score (OKS), American Knee Society Score (AKSS), Hannover Functional Ability Questionnaire for Osteoarthritis (FFbH-OA), range of motion (ROM)), pain and satisfaction. Radiographs were analyzed regarding the incidence of radiolucent lines (RL), implant positioning, and their possible impact on clinical outcome. (3) Results: At a mean follow-up of 37.1 months, the two and three year revision free survival-rates were 97.5% and 96.9%. Reasons for revision surgery were progression of osteoarthritis, inlay dislocation and pain. All clinical outcome scores showed a significant improvement from pre- to postoperative. The incidence of RL around the implant was highest within the first year postoperatively (36%), and decreased (5%) within the second year. Their presence was not correlated with inferior clinical outcome. Implant positioning showed no influence on clinical outcome. (4) Conclusion: Cementless OUKR showed excellent clinical outcome and survival rates, with reliable osteointegration. Neither the incidence of radiolucent lines nor implant positioning were associated with inferior clinical outcome.

4.
BMC Musculoskelet Disord ; 19(1): 18, 2018 01 17.
Article de Anglais | MEDLINE | ID: mdl-29343231

RÉSUMÉ

BACKGROUND: Physical activity and regular participation in recreational sports gain importance in patients' lifestyle after knee arthroplasty. Cementless unicompartimental Knee replacement with the Oxford System has been introduced into clinical routine. Currently there is no data reporting on the physical activity, return to sports rate and quality of live after medial cementless Oxford Unicompartimental Knee Replacement (OUKR). METHODS: This retrospective cohort study reports on the functional outcome of the first 27 consecutive patients (30 knees) that were consecutively treated with a cementless medial OUKR between 2007 and 2009 in our hospital. Physical activity and quality of life were measured using the Tegner-Score, the UCLA-Activity Score, the Schulthess Clinical Activity Questionnaire and the SF-36 Score. The patients' satisfaction with the outcome was measured using a visual analogue scale. RESULTS: Mean age at surgery was 62.5 years. Patients showed a rapid recovery with 17 out of 27 patients returning to sports within 3 months, 24 within 6 months after surgery. The Return-to-activity-rate was 100%. 10 out of 27 patients showed a high activity level (UCLA ≥7 points) with a mean postoperative UCLA-Score of 6.1 points. CONCLUSIONS: Patients recover rapidly after cementless OUKR with a return to sports rate of 100% and patients are able to participate in high impact sports disciplines.


Sujet(s)
Activités de la vie quotidienne , Arthroplastie prothétique de genou/méthodes , Exercice physique/physiologie , Récupération fonctionnelle/physiologie , Activités de la vie quotidienne/psychologie , Sujet âgé , Arthroplastie prothétique de genou/psychologie , Ciments osseux , Études de cohortes , Exercice physique/psychologie , Femelle , Humains , Mâle , Adulte d'âge moyen , Études rétrospectives , Facteurs temps
5.
Arch Orthop Trauma Surg ; 137(7): 1011-1017, 2017 Jul.
Article de Anglais | MEDLINE | ID: mdl-28439705

RÉSUMÉ

PURPOSE: Cemented unicompartmental knee replacement (UKR) has proven excellent long-term survival rates and functional scores in Price et al. (Clin Orthop Relat Res 435:171-180, 2005), Price and Svard (Clin Orthop Relat Res 469(1):174-179, 2011) and Murray et al. (Bone Joint Surg Br 80(6):983-989, 1998). The main causes for revision, aseptic loosening and pain of unknown origin might be addressed by cementless UKR in Liddle et al. (Bone Joint J 95-B(2):181-187, 2013), Pandit et al. (J Bone Joint Surg Am 95(15):1365-1372, 2013), National Joint Registry for England, Wales and Northern Ireland: 10th Annual Report 2013 ( http://www.njrcentre.org.uk/njrcentre/Portals/0/Documents/England/Reports/10th_annual_report/NJR%2010th%20Annual%20Report%202013%20B.pdf , 2013), Swedish Knee Arthroplasty Register: Annual Report 2013 ( http://www.myknee.se/pdf/SKAR2013_Eng.pdf , 2013). METHODS: This single-centre retrospective cohort study reports the 5-year follow-up results of our first 30 consecutively implanted cementless Oxford UKR (OUKR). Clinical outcome was measured using the OKS, AKSS, range of movement and level of pain (visual analogue scale). The results were compared to cemented OUKR in a matched-pair analysis. RESULTS: Implant survival was 89.7%. One revision each was performed due to tibial fracture, progression of osteoarthritis (OA) and inlay dislocation. The 5-year survival rate of the cementless group was 89.7% and of the cemented group 94.1%. Both groups showed excellent postoperative clinical scores. CONCLUSIONS: Cementless fixation shows good survival rates and clinical outcome compared to cemented fixation.


Sujet(s)
Prothèse de genou , Gonarthrose/chirurgie , Conception de prothèse , Sujet âgé , Arthroplastie prothétique de genou/méthodes , Ciments osseux , Études de cohortes , Femelle , Études de suivi , Allemagne , Humains , Mâle , Mesure de la douleur , Douleur postopératoire , Enregistrements , Études rétrospectives
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE