1.
Article de Anglais | MEDLINE | ID: mdl-39161109

RÉSUMÉ

INTRODUCTION: Modern cardiovascular implantable electronic devices (CIEDs) have mechanisms that prevent damage from external electric shocks, and malfunction following accidental electrocution is rare. However, the effects of lightning injuries in patients with CIEDs are uncertain. CASE PRESENTATION: A 74-year-old man with a dual-chamber pacemaker due to complete heart block was struck by a lightning while farming. He had no serious injury at the time and sought medical evaluation 1 month later, when he presented with asymptomatic bradycardia. Device interrogation suggested major battery and lead damage, requiring extraction and subsequent placement of a new pacing system. DISCUSSION: While a previous report depicted pacing threshold elevation without extensive device impairment, our patient presented with major damage to the whole pacing system. The factors contributing to these divergent outcomes are unclear. Differences in injury mechanism, pacemaker model, and the pattern of electric current dispersion within the device may each play a part in this discrepancy.

2.
Curr Cardiol Rep ; 26(8): 789-799, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38869811

RÉSUMÉ

BACKGROUND: Leadless pacemakers (LPs) are promising alternatives to traditional transvenous pacemakers (TVPs), but their comparative effectiveness and safety in clinical outcomes remain uncertain. METHODS: We systematically searched PubMed, Embase, Scopus, Cochrane, and ClinicalTrials.gov for studies comparing LPs and TVPs. A restricted maximum likelihood random-effects model was used for all outcomes. Heterogeneity was assessed using I2 statistics. We performed a subgroup analysis with studies with multivariate-adjusted data. RESULTS: We included 21 studies involving 47,229 patients, of whom 12,199 (25.8%) underwent LP implantation. Compared with TVPs, LPs were associated with a significantly lower risk of overall complications (OR 0.61; 95% CI 0.45-0.81; p < 0.01), dislodgement (OR 0.34; 95% CI 0.20-0.56; p < 0.01), and pneumothorax (OR 0.27; 95% CI 0.16-0.46; p < 0.01). No significant difference in all-cause mortality was observed in the overall analysis (OR 1.43; 95% CI 0.65-3.15; p = 0.35) and in studies with multivariate-adjusted data (OR 1.34; 95% CI 0.65-2.78; p = 0.43). However, LPs were associated with a higher risk of pericardial effusion (OR 2.47; 95% CI 1.39-4.38; p < 0.01) and cardiac tamponade (OR 3.75; 95% CI 2.41-5.83; p < 0.01). LPs also demonstrated a lower pacing capture threshold (MD -0.19 V; 95% CI [-0.23 V]-[-0.16 V]; p < 0.01), but no significant difference in impedance (MD 32.63 ohms; 95% CI [-22.50 ohms]-[87.76 ohms]; p = 0.25). CONCLUSIONS: These findings suggest that LPs were associated with lower overall complication rates and similar effectiveness to TVPs. However, randomized controlled trials are warranted to validate these results.


Sujet(s)
Pacemaker , Humains , Troubles du rythme cardiaque/thérapie , Entraînement électrosystolique/effets indésirables , Conception d'appareillage , Complications postopératoires , Résultat thérapeutique
3.
Rev. Fac. Med. UNAM ; 67(3): 22-31, may.-jun. 2024. tab, graf
Article de Espagnol | LILACS-Express | LILACS | ID: biblio-1569543

RÉSUMÉ

Resumen El diagnóstico electrocardiográfico de infarto agudo de miocardio (IAM) en el paciente con marcapasos siempre ha sido un problema en la práctica clínica, provocando retrasos en el manejo y peores desenlaces clínicos. Aunque el bloqueo completo de rama izquierda (BCRI) y la estimulación del ventrículo derecho pueden producir anomalías en el electrocardiograma (ECG), cambios morfológicos específicos a menudo permiten el diagnóstico de IAM o un infarto antiguo. Reporte de caso: Paciente de 76 años con antecedente de implante de marcapasos definitivo por bloqueo auriculoventricular de 3° grado, que ingresó por dolor precordial. A su ingreso hemodinámicamente estable, pero con ECG que muestra ritmo de marcapasos con BCRI cumpliendo Sgarbossa 2 puntos (elevación discordante del segmento ST > 5 mm en derivaciones V1 a V3) y relación ST/S < -0.25 en derivaciones V3-V4. Laboratorios con elevación de troponinas, integrándose diagnóstico de IAM y pasando a angiografía coronaria urgente. Se documentó lesión en arteria coronaria descendente anterior y se implantó stent liberador de fármaco angiográficamente exitoso. Se egresó estable, asintomático y con manejo farmacológico para prevención secundaria. Conclusión: La identificación por ECG de un IAM en pacientes portadores de marcapasos es fundamental para iniciar terapia de reperfusión. Las recomendaciones de las guías cambian constantemente, pero un algoritmo que utiliza la inestabilidad hemodinámica y los criterios de Sgarbossa modificados (CSM) para decidir el manejo de estos pacientes pudiera ser una herramienta con una alta sensibilidad y permitirá a los médicos tener la mejor toma de decisiones sin esperar resultados de laboratorio. Los CSM, que son más sensibles que los criterios originales, continúan siendo útiles en el diagnóstico de IAM. Los médicos deben elegir cuidadosamente el límite de CSM apropiado (relación ST/T -0.20 y -0.25) de acuerdo con cada caso.


Abstract The electrocardiographic diagnosis of acute myocardial infarction (AMI) in patients with pacemakers has always been a problem in clinical practice, causing delays in management and worse clinical outcomes. Although complete left bundle branch block (LBBB) and right ventricular pacing can produce electrocardiogram (ECG) abnormalities, specific morphological changes often allow the diagnosis of AMI or an old infarction. Case report: A 76-year-old patient with history of permanent pacemaker implantation due to a 3rd-degree atrioventricular block was admitted for chest pain. Upon admission, he was hemodynamically stable but with ECG showing pacemaker rhythm with LBBB fulfilling 2 points of Sgarbossa criteria (discordant elevation of the ST segment > 5 mm in leads V1 to V3) and ST/S ratio < -0.25 in leads V3-V4. Laboratories showed elevated troponins, integrating diagnosis of AMI, and moving on to urgent coronary angiography. A lesion on the anterior descending coronary artery was documented, and a drug-eluting stent was successfully implanted. The patient was discharged stable, asymptomatic, and with pharmacological management for secondary prevention. Conclusion: ECG identification of an AMI in patients with pacemakers is essential to initiate reperfusion therapy. Guideline recommendations are constantly changing, but an algorithm that uses hemodynamic instability and the modified Sgarbossa criteria (MSC) to decide these patients' management could be a high-sensitivity tool and allow physicians to make the best decisions without waiting for laboratory results. MSC, which are more sensitive than the original criteria, continue to be helpful in the diagnosis of AMI. Clinicians should carefully choose the appropriate MSC cut-off (ST/T Ratio -0.20 and -0.25) on a case-by-case basis.

4.
J Innov Card Rhythm Manag ; 15(4): 5829-5837, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38715549

RÉSUMÉ

Permanent right ventricular apical pacing deteriorates cardiac systolic function in some patients. We investigated an alternative site for permanent pacemaker (PPM) lead positioning with the goal of achieving more physiological pacing. A total of 132 patients with bradyarrhythmias underwent PPM implantation at the right ventricular outflow tract (RVOT) with conventional active-fixation leads. A real-time cross-correlation analysis (CCA) was performed using the Synchromax® software (EXO Health, Seattle, WA, USA) to determine the optimal site for ventricular lead implantation based on the cardiac synchrony index. The follow-up period ranged from 6-36 months, and the following parameters were assessed: pacing capture threshold, lead stability, and the need for lead repositioning. Adequate parameters were achieved in 129 patients (98%), and there were no procedure-related complications. At follow-up, no leads were dislodged, pacing thresholds remained stable, and no lead required repositioning. Using real-time CCA as an intraoperative parameter during PPM implantation at the septal RVOT helps to achieve cardiac synchrony in the vast majority of cases. This technique is a simple, effective, and safe way to simplify and standardize PPM implantation at the RVOT.

6.
Arq. bras. cardiol ; Arq. bras. cardiol;121(4): e20230386, abr.2024. tab, graf
Article de Portugais | LILACS-Express | LILACS | ID: biblio-1557037

RÉSUMÉ

Resumo Fundamento O uso de marca-passos cardíacos artificiais tem crescido constantemente, acompanhando o envelhecimento populacional. Objetivos Determinar as taxas de readmissões hospitalares e complicações após implante de marca-passo ou troca de gerador de pulsos e avaliar o impacto desses eventos nos custos anuais do tratamento sob a perspectiva do Sistema Único de Saúde (SUS). Métodos Registro prospectivo, com dados derivados da prática clínica assistencial, coletados na hospitalização índice e durante os primeiros 12 meses após o procedimento cirúrgico. O custo da hospitalização índice, do procedimento e do seguimento clínico foram estimados de acordo com os valores reembolsados pelo SUS e analisados ao nível do paciente. Modelos lineares generalizados foram utilizados para estudar fatores associados ao custo total anual do tratamento, adotando-se um nível de significância de 5%. Resultados No total, 1.223 pacientes consecutivos foram submetidos a implante inicial (n= 634) ou troca do gerador de pulsos (n= 589). Foram observados 70 episódios de complicação em 63 pacientes (5,1%). A incidência de readmissões hospitalares em um ano foi de 16,4% (IC 95% 13,7% - 19,6%) após implantes iniciais e 10,6% (IC 95% 8,3% - 13,4%) após trocas de geradores. Doença renal crônica, histórico de acidente vascular encefálico, tempo de permanência hospitalar, necessidade de cuidados intensivos pós-operatórios, complicações e readmissões hospitalares mostraram um impacto significativo sobre o custo anual total do tratamento. Conclusões Os resultados confirmam a influência da idade, comorbidades, complicações pós-operatórias e readmissões hospitalares como fatores associados ao incremento do custo total anual do tratamento de pacientes com marca-passo.


Abstract Background The use of artificial cardiac pacemakers has grown steadily in line with the aging population. Objectives To determine the rates of hospital readmissions and complications after pacemaker implantation or pulse generator replacement and to assess the impact of these events on annual treatment costs from the perspective of the Unified Health System (SUS). Methods A prospective registry, with data derived from clinical practice, collected during index hospitalization and during the first 12 months after the surgical procedure. The cost of index hospitalization, the procedure, and clinical follow-up were estimated according to the values reimbursed by SUS and analyzed at the patient level. Generalized linear models were used to study factors associated with the total annual treatment cost, adopting a significance level of 5%. Results A total of 1,223 consecutive patients underwent initial implantation (n=634) or pulse generator replacement (n=589). Seventy episodes of complication were observed in 63 patients (5.1%). The incidence of hospital readmissions within one year was 16.4% (95% CI 13.7% - 19.6%) after initial implants and 10.6% (95% CI 8.3% - 13.4%) after generator replacements. Chronic kidney disease, history of stroke, length of hospital stays, need for postoperative intensive care, complications, and hospital readmissions showed a significant impact on the total annual treatment cost. Conclusions The results confirm the influence of age, comorbidities, postoperative complications, and hospital readmissions as factors associated with increased total annual treatment cost for patients with pacemakers.

8.
Heart Rhythm O2 ; 5(2): 85-94, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-38545328

RÉSUMÉ

Background: Leadless pacing has recently emerged as a promising therapy. The impact of frailty on the prognosis of these patients is currently unknown. Objective: The purpose of this study was to assess the association between frailty and clinical outcomes in patients undergoing leadless pacemaker implantation. Methods: We included adult patients who underwent leadless pacemaker implantation using the National Inpatient Sample from 2017 to 2019. Frailty was evaluated using the Hospital Frailty Risk Score and stratified into low, intermediate, and high risk. Primary outcomes were in-hospital mortality and any complication (vascular, pericardial, pneumothorax, infectious, or device related), and secondary outcomes were the length of hospital stay and total charges. Results: A total of 16,825 patients were included in the final analysis, with 62% at intermediate or high risk of frailty. There was a higher risk of in-hospital mortality in patients at high (adjusted risk ratio [aRR] 6.37, 95% confidence interval [CI] 3.31-12.26) or intermediate (aRR 5.15, 95% CI 3.04-8.72) risk of frailty compared with those at low risk. Similarly, those at high or intermediate risk of frailty had higher total expenses and stayed in the hospital longer. Patients with a high (aRR 1.14, 95% CI 0.71-1.81) or intermediate (aRR 1.19, 95% CI 0.94-1.51) risk of frailty had a similar risk of any complication as patients with a low risk. Conclusion: Frailty was common in patients undergoing leadless pacemaker implantation. Higher levels of frailty were a strong predictor of in-hospital mortality, length of hospital stay, and hospital charges, except for any complication.

9.
J Cardiovasc Electrophysiol ; 35(4): 641-650, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38240356

RÉSUMÉ

BACKGROUND: Cardioneuroablation (CNA) is a novel therapeutic approach for functional bradyarrhythmias, specifically neurocardiogenic syncope or atrial fibrillation, achieved through endocardial radiofrequency catheter ablation of vagal innervation, obviating the need for pacemaker implantation. Originating in the nineties, the first series of CNA procedures was published in 2005. Extra-cardiac vagal stimulation (ECVS) is employed as a direct method for stepwise denervation control during CNA. OBJECTIVE: This study aimed to compare the long-term follow-up outcomes of patients with severe cardioinhibitory syncope undergoing CNA with and without denervation confirmation via ECVS. METHOD: A cohort of 48 patients, predominantly female (56.3%), suffering from recurrent syncope (5.1 ± 2.5 episodes annually) that remained unresponsive to clinical and pharmacological interventions, underwent CNA, divided into two groups: ECVS and NoECVS, consisting of 34 and 14 cases, respectively. ECVS procedures were conducted with and without atrial pacing. RESULTS: Demographic characteristics, left atrial size, and ejection fraction displayed no statistically significant differences between the groups. Follow-up duration was comparable, with 29.1 ± 15 months for the ECVS group and 31.9 ± 20 months for the NoECVS group (p = .24). Notably, syncope recurrence was significantly lower in the ECVS group (two cases vs. four cases, Log Rank p = .04). Moreover, the Hazard ratio revealed a fivefold higher risk of syncope recurrence in the NoECVS group. CONCLUSION: This study demonstrates that concluding CNA with denervation confirmation via ECVS yields a higher success rate and a substantially reduced risk of syncope recurrence compared to procedures without ECVS confirmation.


Sujet(s)
Syncope vagale , Humains , Femelle , Mâle , Syncope vagale/diagnostic , Syncope vagale/chirurgie , Syncope , Atrium du coeur , Bradycardie/chirurgie , Nerf vague/chirurgie
10.
Pacing Clin Electrophysiol ; 47(1): 36-44, 2024 01.
Article de Anglais | MEDLINE | ID: mdl-38041423

RÉSUMÉ

INTRODUCTION: Transvenous temporary pacemaker (TvTP) implantation is a critical procedure often performed under time limitations, playing a crucial role in patient survival. However, the amount of training provided for resident cardiologists is variable, due to the availability of patients. Thus, the use of simulators for this cardiologic procedure could be used as training tools. OBJECTIVE: The present study aimed to develop a simulator system for TvTP implantation based on electrograms, called ETTIS (Electrogram-guided Transvenous Temporary-pacemaker Implantation Simulator), and to evaluate its educational potential and cardiology residents' perceived learning efficacy as a training tool. METHODOLOGY: The development of the ETTIS involved three stages: (1) Adaptation of an anatomical mannequin; (2) Design and manufacture of electronic circuits and software capable of identifying the catheter contact site within the heart chambers and reproducing electrograms in both surfaces (mode-on) and intracavitary (mode-off); (3) To evaluate its educational potential, a modified Likert questionnaire was administered to nine cardiology experts. Additionally, to evaluate the perceived learning efficacy, another modified Likert questionnaire was given to six cardiology residents both before and after training with the ETTIS. Descriptive statistics with measures of position and dispersion were employed, and the weighted Kappa test was used for agreement analysis. RESULTS: A high rate of acceptance (over 90%) was found among experts who evaluated the ETTIS. The cardiology residents showed significant self-perceived learning gains, as evidenced by a lack of agreement between their responses to a questionnaire before and after training. CONCLUSION: The ETTIS is a promising tool for medical training, displaying both educational potential and efficacy. It has been shown to be effective in learning a variety of skills, including cardiac catheterization and electrophysiology. Additionally, the ETTIS is highly engaging and allows cardiology residents to practice in a safe and controlled environment.


Sujet(s)
Cardiologues , Internat et résidence , Pacemaker , Humains , Enquêtes et questionnaires , Prothèses et implants , Compétence clinique
11.
Pacing Clin Electrophysiol ; 47(1): 101-105, 2024 01.
Article de Anglais | MEDLINE | ID: mdl-37158275

RÉSUMÉ

Coronary artery lesions related to pacemaker implantation are rare complications. With the increasing adoption of the technique of permanent transseptal pacing of the left bundle branch area pacing (LBBAP), an increase in the incidence of these complications may be expected. We report two cases of coronary lesions after permanent transeptal pacing of the LBBAP: the first with a small coronary artery fistula, and the second with an extrinsic coronary compression. Both complications occurred with stylet-driven pacing leads with extendable helix. In the first case, since the shunt volume was small and no major complications were reported, the patient was treated conservatively with good outcome. The second case required lead repositioning due to acute decompensated heart failure.


Sujet(s)
Défaillance cardiaque , Septum interventriculaire , Humains , Entraînement électrosystolique/effets indésirables , Entraînement électrosystolique/méthodes , Vaisseaux coronaires , Électrocardiographie/méthodes , Système de conduction du coeur , Défaillance cardiaque/étiologie , Défaillance cardiaque/prévention et contrôle , Faisceau de His , Résultat thérapeutique
12.
Article de Anglais | MEDLINE | ID: mdl-37002418

RÉSUMÉ

Living organisms display molecular, physiological and behavioral rhythms synchronized with natural environmental cycles. Understanding the interaction between environment, physiology and behavior requires taking into account the complexity of natural habitats and the diversity of behavioral and physiological adaptations. Brachyhypopomus gauderio is characterized by the emission of electric organ discharges (EOD), with a very stable rate modulated by social and environmental cues. The nocturnal arousal in B. gauderio coincides with a melatonin-dependent EOD rate increase. Here, we first show a daily cycle in both the EOD basal rate (EOD-BR) and EOD-BR variability of B. gauderio in nature. We approached the understanding of the role of melatonin in this natural behavior through both behavioral pharmacology and in vitro assays. We report, for the first time in gymnotiformes, a direct effect of melatonin on the pacemaker nucleus (PN) in in vitro preparation. Melatonin treatment lowered EOD-BR in freely moving fish and PN basal rate, while increasing the variability of both. These results show that melatonin plays a key role in modulating the electric behavior of B. gauderio through its effect on rate and variability, both of which must be under a tight temporal regulation to prepare the animal for the challenging nocturnal environment.


Sujet(s)
Poisson électrique , Gymnotiformes , Mélatonine , Animaux , Poisson électrique/physiologie , Mélatonine/pharmacologie , Gymnotiformes/physiologie , Organe électrique/physiologie , Comportement animal/physiologie
14.
Belo Horizonte; s.n; 2024. 67 p. ilus.
Thèse de Portugais | LILACS | ID: biblio-1566141

RÉSUMÉ

Fundamento: A cardiomiopatia chagásica (CCh) é responsável pelo implante de marcapasso (MP) em muitos pacientes, tendo sido associada a prognóstico adverso. Objetivos: Comparar o prognóstico da população chagásica e não chagásica submetida ao implante de MP e ressincronizador cardíaco. Métodos: Estudo observacional, retrospectivo, que analisou coorte de pacientes submetidos a implante desses dispositivos, em centro terciário, de Outubro 2007 a Dezembro de 2017, comparando o grupo de pacientes chagásicos com os não-chagásicos. O desfecho primário foi a mortalidade por qualquer causa, enquanto os desfechos secundários foram a ocorrência de internação e o desfecho combinado internação e morte. Resultados: Um total de 911 pacientes foram incluídos, sendo que 23,4% apresentavam CCh. Em análise de Cox ajustada por sexo e idade, a doença de Chagas (dCh) não esteve associada ao risco aumentado de morte (HR: 1,14, IC:95%, 0,86-1,51, p=0,365), internação (HR: 0,79, IC:95%, 0,61-1,04, p=0,09) ou desfecho combinado morte e internação (HR: 0,90, IC:95%, 0,72-1,12, p=0,49). Conclusões: A dCh não se associou ao aumento do risco de morte, internação, ou desfecho combinado morte e internação, mesmo após ajuste para sexo e idade. Trabalhos semelhantes ainda não foram publicados na literatura vigente considerando-se especificamente a população chagásica portadora de dispositivos cardíacos, e novos estudos são necessários para se confirmar esses achados


Background: Chagas cardiomyopathy (ChCC) is responsible for the implantation of pacemaker (PM) in many patients and has been associated with an adverse prognosis. Objectives: To compare the prognosis of the chagasic and non-chagasic population undergoing PM and cardiac resynchronizer implantation. Methods: Observational, retrospective study, which analyzed a cohort of patients who underwent implantation of these devices, in a tertiary center, from October 2007 to December 2017, comparing the group of chagasic with non-chagasic patients. The primary outcome was mortality from any cause, while the secondary outcomes were the occurrence of hospitalization and the combined outcome of hospitalization and death. Results: A total of 911 patients were included, of which 23.4% had ChCC. In a Cox analysis adjusted for sex and age, Chagas disease (ChD) was not associated with an increased risk of death (HR: 1.14, CI:95%, 0.86-1.51, p=0.365), hospitalization (HR: 0.79, CI:95%, 0.61-1.04, p=0.09) or combined outcome of death and hospitalization (HR: 0.90, CI:95%, 0.72-1 .12, p=0.49). Conclusions: ChD was not associated with an increased risk of death, hospitalization, or combined outcome of death and hospitalization, even after adjustment for sex and age. Similar studies have not yet been published in the current literature specifically considering the chagasic population with cardiac devices, and new studies are needed to confirm these findings.


Sujet(s)
Pacemaker , Entraînement électrosystolique , Cardiomyopathie associée à la maladie de Chagas , Pronostic , Études rétrospectives , Dissertation universitaire , Centres de soins tertiaires
15.
Eur Heart J Suppl ; 25(Suppl H): H1-H17, 2023 Dec.
Article de Anglais | MEDLINE | ID: mdl-38046890

RÉSUMÉ

Bradycardia, a condition characterized by an abnormally slow heart rate, poses significant challenges in terms of diagnosis and treatment. While it is a concern world-wide, low- and middle-income countries (LMICs) face substantial barriers in accessing appropriate bradycardia therapy. This article aims to explore the global aetiology and incidence of bradycardia, compare the prevalence and management of the condition in high-income countries versus LMICs, identify the key reasons behind the disparities in access to bradycardia therapy in LMICs, and emphasize the urgent need to address these disparities to ensure equitable healthcare on a global scale.

16.
Arch. cardiol. Méx ; Arch. cardiol. Méx;93(4): 398-404, Oct.-Dec. 2023. tab, graf
Article de Anglais | LILACS-Express | LILACS | ID: biblio-1527716

RÉSUMÉ

Abstract Objective: The objective of the study was to establish the prognostic value of CSNRT regarding the necessity for pacemaker implantation in patients with atrial flutter (AFL) post-ablation. Methods: This prospective cohort study, conducted at the National Institute of Cardiology "Ignacio Chavez" in Mexico City, assessed patients who had undergone ablation procedures to correct AFL, posterior to which an autonomic blockade was performed, and CSNRT was measured. Results: The sample for this investigation was 40 patients. These were subdivided into two study groups depending on their requirement of pacemaker implant post-ablation (Pacemaker P, No Pacemaker NP). Sinus node (SN) dysfunction was diagnosed in 13 (32.5%) of the 40 participants, 10 (71.43%) of which required a pacemaker implant, while only 4 participants (28.57%) with normal SN function required pacemakers. Ten out of the 14 patients (71.43%) who required a pacemaker had an elevated CSNRT > 500 ms (p ≤ 0.01). Post-ablation CSNRT mean was 383.54 ms ± 67.96 ms in the NP group versus 1972.57 ms ± 3423.56 ms in the P group. Furthermore, SN pause in the P group had a mean of 1.86 s ± 0.96 s versus the NP group with 1.196 s ± 0.52 s. Conclusion: CSNRT has the potential to be a quantitative prognostic tool for the assessment of future pacemaker implants in patients with AFL post-ablation. This could aid in the timely diagnosis of sinus node dysfunction, which could, in the long run, result in the reduction of cardiac functional capacity loss due to cardiac remodeling.


Resumen Objetivo: Establecer el valor pronóstico del TRNSC basado en la necesidad de marcapasos en pacientes diagnosticados con aleteo atrial, pos-ablación. Métodos: Este cohorte prospectivo, realizado en el Instituto Nacional de Cardiología "Ignacio Chávez" en la Ciudad de México, evaluó pacientes sometidos a ablación para corregir el aleteo atrial; se midió el TRNSC post bloqueo autonómico. Resultados: La muestra de 40 pacientes se subdividió en 2 grupos según su requerimiento de marcapasos posterior a la ablación (P y NP). Se diagnosticó disfunción del nodo sinusal en 13 participantes (32.5%), de los cuales 10 (71.43%) requirieron marcapasos en comparación a 4 (28.57%) con función normal. En el grupo P la pausa del nodo sinusal post-ablación tuvo una media de 1.86 ± 0.96 s versus el grupo NP con 1.196 ± 0.52 s. En relación con el TRNSC, el grupo NP tuvo una media de 383.54 ± 67.96 ms vs. 1972.57 ± 3423.56 ms en el grupo P. 10 pacientes (25%) obtuvieron un TRNSC > 500 ms, de los cuales 100% requirieron marcapasos; de los 14 pacientes que requirieron marcapasos 10 (71.43%) tenían un TRNSC elevado (p ≤ 0.01). Conclusiones: El TRNSC tiene el potencial de ser una herramienta de pronóstico cuantitativo para la necesidad de futuros implantes de marcapasos en pacientes con disfunción del nodo sinusal, resultado de aleteo atrial pos-ablación. Esto podría ayudar a diagnosticar más temprano una disfunción del nodo sinusal, resultando en la reducción de la pérdida a largo plazo de la función cardíaca como efecto de la remodelación.

18.
Cancers (Basel) ; 15(21)2023 Oct 29.
Article de Anglais | MEDLINE | ID: mdl-37958380

RÉSUMÉ

Cancer is the abnormal proliferation of physiologically inadequate cells. Studies have identified the cardiac pacemaker pocket as a site of rare neoplasms. To evaluate the clinical outcomes, treatment, prognosis, and individualized management of tumors originating in the cardiac pacemaker pocket, a systematic review was conducted using case reports and case series available in the PubMed/Medline, Science Direct, Cochrane Central, LILACS, and Scientific Electronic Library Online (Scielo) databases. Pacemaker pocket tumors affected patients with a mean age of 72.9 years, with a higher incidence in males (76.9%, n = 10). The average time for neoplasm development was 4.4 years (54.07 months). The most prevalent model was Medtronic (38.4%, n = 5), with titanium (83.3%) being the most common metal composition. Chemotherapy was the most performed procedure among patients (38.4%), followed by radiation therapy (38.4%) and surgical tumor resection (30.7%). Six analyzed cases (46.1%) resulted in death, and four patients (30.7%) achieved a cure. Patients with pacemakers should be routinely evaluated for the occurrence of malignant tumors at the site of device implantation.

19.
Arch Cardiol Mex ; 93(4): 398-404, 2023.
Article de Anglais | MEDLINE | ID: mdl-37972358

RÉSUMÉ

OBJECTIVE: The objective of the study was to establish the prognostic value of CSNRT regarding the necessity for pacemaker implantation in patients with atrial flutter (AFL) post-ablation. METHODS: This prospective cohort study, conducted at the National Institute of Cardiology "Ignacio Chavez" in Mexico City, assessed patients who had undergone ablation procedures to correct AFL, posterior to which an autonomic blockade was performed, and CSNRT was measured. RESULTS: The sample for this investigation was 40 patients. These were subdivided into two study groups depending on their requirement of pacemaker implant post-ablation (Pacemaker P, No Pacemaker NP). Sinus node (SN) dysfunction was diagnosed in 13 (32.5%) of the 40 participants, 10 (71.43%) of which required a pacemaker implant, while only 4 participants (28.57%) with normal SN function required pacemakers. Ten out of the 14 patients (71.43%) who required a pacemaker had an elevated CSNRT > 500 ms (p ≤ 0.01). Post-ablation CSNRT mean was 383.54 ms ± 67.96 ms in the NP group versus 1972.57 ms ± 3423.56 ms in the P group. Furthermore, SN pause in the P group had a mean of 1.86 s ± 0.96 s versus the NP group with 1.196 s ± 0.52 s. CONCLUSION: CSNRT has the potential to be a quantitative prognostic tool for the assessment of future pacemaker implants in patients with AFL post-ablation. This could aid in the timely diagnosis of sinus node dysfunction, which could, in the long run, result in the reduction of cardiac functional capacity loss due to cardiac remodeling.


OBJETIVO: Establecer el valor pronóstico del TRNSC basado en la necesidad de marcapasos en pacientes diagnosticados con aleteo atrial, pos-ablación. MÉTODOS: Este cohorte prospectivo, realizado en el Instituto Nacional de Cardiología "Ignacio Chávez" en la Ciudad de México, evaluó pacientes sometidos a ablación para corregir el aleteo atrial; se midió el TRNSC post bloqueo autonómico. RESULTADOS: La muestra de 40 pacientes se subdividió en 2 grupos según su requerimiento de marcapasos posterior a la ablación (P y NP). Se diagnosticó disfunción del nodo sinusal en 13 participantes (32.5%), de los cuales 10 (71.43%) requirieron marcapasos en comparación a 4 (28.57%) con función normal. En el grupo P la pausa del nodo sinusal post-ablación tuvo una media de 1.86 ± 0.96 s versus el grupo NP con 1.196 ± 0.52 s. En relación con el TRNSC, el grupo NP tuvo una media de 383.54 ± 67.96 ms vs. 1972.57 ± 3423.56 ms en el grupo P. 10 pacientes (25%) obtuvieron un TRNSC > 500 ms, de los cuales 100% requirieron marcapasos; de los 14 pacientes que requirieron marcapasos 10 (71.43%) tenían un TRNSC elevado (p ≤ 0.01). CONCLUSIONES: El TRNSC tiene el potencial de ser una herramienta de pronóstico cuantitativo para la necesidad de futuros implantes de marcapasos en pacientes con disfunción del nodo sinusal, resultado de aleteo atrial pos-ablación. Esto podría ayudar a diagnosticar más temprano una disfunción del nodo sinusal, resultando en la reducción de la pérdida a largo plazo de la función cardíaca como efecto de la remodelación.


Sujet(s)
Fibrillation auriculaire , Flutter auriculaire , Ablation par cathéter , Pacemaker , Humains , Noeud sinuatrial/chirurgie , Flutter auriculaire/diagnostic , Flutter auriculaire/chirurgie , Études prospectives , Électrocardiographie , Maladie du sinus/diagnostic , Maladie du sinus/thérapie , Fibrillation auriculaire/chirurgie , Résultat thérapeutique
20.
MethodsX ; 11: 102454, 2023 Dec.
Article de Anglais | MEDLINE | ID: mdl-37920872

RÉSUMÉ

Data quality monitoring plays a crucial role in multicenter prospective registries. By maintaining high data accuracy, completeness, and consistency, researchers can improve the overall quality and reliability of the registry data, enabling meaningful conclusions and supporting evidence-based decisions. The purpose of the present study was to evaluate data quality metrics (completeness, accuracy, and temporal plausibility) of a Multicenter Registry of Cardiac Implantable Electronic Devices (CIEDs) and to perform a direct data audit of a random sample of records to assess the agreement levels with the source documents. The CIED Registry was a prospective, multicenter, real-world observational study carried out from January 2020 to December 2022 in five designated centers across Sao Paulo, Brazil. We assessed the data quality of the CIED Registry by using two distinct approaches:•Dynamic data monitoring using features of the REDCap (Research Electronic Data Capture) software, including data reports and data quality rules•Direct data audit in which information from a random sample of 10 % of cases from the coordinating center was compared with original source documents Our findings suggest that the methodological approach applied to the CIED Registry resulted in high data completeness, accuracy, temporal plausibility, and excellent agreement levels with the source documents.