Résultats 1 - 20 de 954
Filtrer
1.
Front Digit Health ; 6: 1337667, 2024.
Article de Anglais | MEDLINE | ID: mdl-38946728

RÉSUMÉ

Introduction: Heart rate variability biofeedback (HRVB) is a well-studied intervention known for its positive effects on emotional, cognitive, and physiological well-being, including relief from depressive symptoms. However, its practical use is hampered by high costs and a lack of trained professionals. Smartphone-based HRVB, which eliminates the need for external devices, offers a promising alternative, albeit with limited research. Additionally, premenstrual symptoms are highly prevalent among menstruating individuals, and there is a need for low-cost, accessible interventions with minimal side effects. With this pilot study, we aim to test, for the first time, the influence of smartphone-based HRVB on depressive and premenstrual symptoms, as well as anxiety/stress symptoms and attentional control. Methods: Twenty-seven participants with above-average premenstrual or depressive symptoms underwent a 4-week photoplethysmography smartphone-based HRVB intervention using a waitlist-control design. Laboratory sessions were conducted before and after the intervention, spaced exactly 4 weeks apart. Assessments included resting vagally mediated heart rate variability (vmHRV), attentional control via the revised attention network test (ANT-R), depressive symptoms assessed with the BDI-II questionnaire, and stress/anxiety symptoms measured using the DASS questionnaire. Premenstrual symptomatology was recorded through the PAF questionnaire if applicable. Data analysis employed linear mixed models. Results: We observed improvements in premenstrual, depressive, and anxiety/stress symptoms, as well as the Executive Functioning Score of the ANT-R during the intervention period but not during the waitlist phase. However, we did not find significant changes in vmHRV or the Orienting Score of the ANT-R. Discussion: These findings are promising, both in terms of the effectiveness of smartphone-based HRVB and its potential to alleviate premenstrual symptoms. Nevertheless, to provide a solid recommendation regarding the use of HRVB for improving premenstrual symptoms, further research with a larger sample size is needed to replicate these effects.

3.
Sensors (Basel) ; 24(11)2024 May 22.
Article de Anglais | MEDLINE | ID: mdl-38894093

RÉSUMÉ

Pulse oximeters are widely used in hospitals and homes for measurement of blood oxygen saturation level (SpO2) and heart rate (HR). Concern has been raised regarding a possible bias in obtaining pulse oximeter measurements from different fingertips and the potential effect of skin pigmentation (white, brown, and dark). In this study, we obtained 600 SpO2 measurements from 20 volunteers using three UK NHS-approved commercial pulse oximeters alongside our custom-developed sensor, and used the Munsell colour system (5YR and 7.5YR cards) to classify the participants' skin pigmentation into three distinct categories (white, brown, and dark). The statistical analysis using ANOVA post hoc tests (Bonferroni correction), a Bland-Altman plot, and a correlation test were then carried out to determine if there was clinical significance in measuring the SpO2 from different fingertips and to highlight if skin pigmentation affects the accuracy of SpO2 measurement. The results indicate that although the three commercial pulse oximeters had different means and standard deviations, these differences had no clinical significance.


Sujet(s)
Doigts , Oxymétrie , Saturation en oxygène , Pigmentation de la peau , Humains , Oxymétrie/méthodes , Oxymétrie/instrumentation , Pigmentation de la peau/physiologie , Doigts/vascularisation , Doigts/physiologie , Saturation en oxygène/physiologie , Mâle , Adulte , Femelle , Oxygène/sang , Oxygène/métabolisme , Rythme cardiaque/physiologie , Jeune adulte
4.
Phlebology ; : 2683555241258308, 2024 Jun 18.
Article de Anglais | MEDLINE | ID: mdl-38887802

RÉSUMÉ

BACGROUND: Impaired venous return is observed in healthcare professionals who spend long periods standing and sitting. This descriptive cross-sectional study was conducted to evaluate varicose vein-related risk factors, exercise health beliefs, and venous refill time in healthcare professionals working in operating rooms and outpatient clinics by photoplethysmography. METHOD: The study sample consisted of 100 healthcare professionals without a diagnosis of peripheral venous insufficiency. Data were collected using a descriptive characteristics form, the Health Belief Model Scale for Exercise, the Short-Form McGill Pain Questionnaire, and photoplethysmography. RESULT: This study found that OR nurses had shorter venous refill times and experienced more pain due to prolonged standing, despite their high health beliefs about exercise. CONCLUSION: Healthcare professionals working in operating rooms should be screened for venous insufficiency and trained regarding the practices to prevent venous insufficiency, such as lying down, elevating legs, and using elastic stockings.

5.
Zhongguo Yi Liao Qi Xie Za Zhi ; 48(3): 285-292, 2024 May 30.
Article de Chinois | MEDLINE | ID: mdl-38863095

RÉSUMÉ

PPG (photoplethysmography) holds significant application value in wearable and intelligent health devices. However, during the acquisition process, PPG signals can generate motion artifacts due to inevitable coupling motion, which diminishes signal quality. In response to the challenge of real-time detection of motion artifacts in PPG signals, this study analyzed the generation and significant features of PPG signal interference. Seven features were extracted from the pulse interval data, and those exhibiting notable changes were filtered using the dual-sample Kolmogorov-Smirnov test. The real-time detection of motion artifacts in PPG signals was ultimately based on decision trees. In the experimental phase, PPG signal data from 20 college students were collected to formulate the experimental dataset. The experimental results demonstrate that the proposed method achieves an average accuracy of (94.07±1.14)%, outperforming commonly used motion artifact detection algorithms in terms of accuracy and real-time performance.


Sujet(s)
Algorithmes , Artéfacts , Arbres de décision , Photopléthysmographie , Traitement du signal assisté par ordinateur , Photopléthysmographie/méthodes , Humains , Déplacement
6.
Biomedicines ; 12(6)2024 May 25.
Article de Anglais | MEDLINE | ID: mdl-38927384

RÉSUMÉ

Intradialytic hypotension (IDH) is a severe complication of hemodialysis (HD) with a significant impact on morbidity and mortality. In this study, we used a wearable device for the continuous monitoring of hemodynamic vitals to detect hemodynamic changes during HD and attempted to identify IDH. End-stage kidney disease patients were continuously monitored 15 min before starting the session and until 15 min after completion of the session, measuring heart rate (HR), noninvasive cuffless systolic and diastolic blood pressure (SBP and DBP), stroke volume (SV), cardiac output (CO), and systemic vascular resistance (SVR). Data were analyzed retrospectively and included comparing BP measured by the wearable devices (recorded continuously every 5 s) and the cuff-based devices. A total of 98 dialysis sessions were included in the final analysis, and IDH was identified in 22 sessions (22.5%). Both SBP and DBP were highly correlated (r > 0.62, p < 0.001 for all) between the wearable device and the cuff-based measurements. Based on the continuous monitoring, patients with IDH had earlier and more profound reductions in SBP and DBP during the HD treatment. In addition, nearly all of the advanced vitals differed between groups. Further studies should be conducted in order to fully understand the potential of noninvasive advanced continuous monitoring in the prediction and prevention of IDH events.

7.
Comput Biol Med ; 177: 108677, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38833800

RÉSUMÉ

Intracranial pressure (ICP) is commonly monitored to guide treatment in patients with serious brain disorders such as traumatic brain injury and stroke. Established methods to assess ICP are resource intensive and highly invasive. We hypothesized that ICP waveforms can be computed noninvasively from three extracranial physiological waveforms routinely acquired in the Intensive Care Unit (ICU): arterial blood pressure (ABP), photoplethysmography (PPG), and electrocardiography (ECG). We evaluated over 600 h of high-frequency (125 Hz) simultaneously acquired ICP, ABP, ECG, and PPG waveform data in 10 patients admitted to the ICU with critical brain disorders. The data were segmented in non-overlapping 10-s windows, and ABP, ECG, and PPG waveforms were used to train deep learning (DL) models to re-create concurrent ICP. The predictive performance of six different DL models was evaluated in single- and multi-patient iterations. The mean average error (MAE) ± SD of the best-performing models was 1.34 ± 0.59 mmHg in the single-patient and 5.10 ± 0.11 mmHg in the multi-patient analysis. Ablation analysis was conducted to compare contributions from single physiologic sources and demonstrated statistically indistinguishable performances across the top DL models for each waveform (MAE±SD 6.33 ± 0.73, 6.65 ± 0.96, and 7.30 ± 1.28 mmHg, respectively, for ECG, PPG, and ABP; p = 0.42). Results support the preliminary feasibility and accuracy of DL-enabled continuous noninvasive ICP waveform computation using extracranial physiological waveforms. With refinement and further validation, this method could represent a safer and more accessible alternative to invasive ICP, enabling assessment and treatment in low-resource settings.


Sujet(s)
Apprentissage profond , Électrocardiographie , Unités de soins intensifs , Pression intracrânienne , Photopléthysmographie , Traitement du signal assisté par ordinateur , Humains , Pression intracrânienne/physiologie , Mâle , Femelle , Adulte d'âge moyen , Adulte , Photopléthysmographie/méthodes , Électrocardiographie/méthodes , Sujet âgé , Monitorage physiologique/méthodes
8.
Comput Methods Programs Biomed ; 253: 108251, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38824806

RÉSUMÉ

BACKGROUND & OBJECTIVES: Measurement of blood pressure (BP) in ambulatory patients is crucial for at high-risk cardiovascular patients. A non-obtrusive, non-occluding device that continuously measures BP via photoplethysmography will enable long-term ambulatory assessment of BP. The aim of this study is to validate the metasense 2PPG cuffless wearable design for continuous BP estimation without ECG. METHODS: A customized high-speed electronic optical sensor architecture with laterally spaced reflectance pulse oximetry was designed into a simple unobtrusive low-power wearable in the form of a watch. 78 volunteers with a mean age of 32.72 ± 7.4 years (21 to 64), 51% male, 49% female were recruited with ECG-2PPG signals acquired. The fiducial features of the 2PPG morphologies were then attributed to the estimator. A 9-1 K-fold cross-validation was applied in the ML. RESULTS: The correlation for PTT-SBP was 0.971 and for PTT-DBP was 0.954. The mean absolute error was 3.167±1.636 mmHg for SBP and 6.4 ± 3.9 mm Hg for DBP. The ambulatory estimate for SBP and DBP for an individual over 3 days with 8-hour recordings was 0.70-0.81 for SBP and 0.42-0.51 for DBP with a ± 2.65 mmHg for SBP and ±2.02 mmHg for DBP. For SBP, 98% of metasense measurements were within 15 mm Hg and for DBP, 91% of metasense measurements were within 10 mmHg CONCLUSIONS: The metasense device provides continuous, non-invasive BP estimations that are comparable to ambulatory BP meters. The portability and unobtrusiveness of this device, as well as the ability to continuously measure BP could one day enable long-term ambulatory BP measurement for precision cardiovascular therapeutic regimens.


Sujet(s)
Mesure de la pression artérielle , Photopléthysmographie , Dispositifs électroniques portables , Humains , Photopléthysmographie/instrumentation , Photopléthysmographie/méthodes , Femelle , Mâle , Adulte , Adulte d'âge moyen , Mesure de la pression artérielle/instrumentation , Mesure de la pression artérielle/méthodes , Pression sanguine , Jeune adulte , Conception d'appareillage , Reproductibilité des résultats , Électrocardiographie/instrumentation
9.
Phlebology ; : 2683555241260542, 2024 Jun 13.
Article de Anglais | MEDLINE | ID: mdl-38868949

RÉSUMÉ

INTRODUCTION: Endovenous ablation may not always be necessary for every patient with chronic venous insufficiency who has an indication for endovenous ablation. This study investigates whether compression stockings and Daflon® can be as effective for some patients with CEAP two in chronic venous insufficiency. METHODS: In this study, 137 patients who had endovenous ablation indication received plethysmographical hemodynamic tests and were divided into two groups. Group 1 had normal venous hemodynamics and received compression stockings and Daflon®. Group 2 had abnormal function and received laser ablation. All patients were reevaluated after 6 months. RESULTS: The study showed that there was no statistically significant difference between Groups 1 and 2 in the 6th month measurements after the treatments. CONCLUSION: As a result, we do not find it appropriate and do not recommend that every patient with complaints of chronic venous insufficiency and an indication for endovenous ablation undergo ablation without evaluating lower extremity venous hemodynamics.

10.
ACS Appl Mater Interfaces ; 16(24): 31399-31406, 2024 Jun 19.
Article de Anglais | MEDLINE | ID: mdl-38836799

RÉSUMÉ

Layered perovskites, a novel class of two-dimensional (2D) layered materials, exhibit versatile photophysical properties of great interest in photovoltaics and optoelectronics. However, their instability to environmental factors, particularly water, has limited their utility. In this study, we introduce an innovative solution to the problem by leveraging the unique properties of natural beeswax as a protective coating of 2D-fluorinated phenylethylammonium lead iodide perovskite. These photodetectors show outstanding figures of merit, such as a responsivity of >2200 A/W and a detectivity of 2.4 × 1018 Jones. The hydrophobic nature of beeswax endows the 2D perovskite sensors with an unprecedented resilience to prolonged immersion in contaminated water, and it increases the lifespan of devices to a period longer than one year. At the same time, the biocompatibility of the beeswax and its self-cleaning properties make it possible to use the very same turbidity sensors for healthcare in photoplethysmography and monitor the human heartbeat with clear systolic and diastolic signatures. Beeswax-enabled multipurpose optoelectronics paves the way to sustainable electronics by ultimately reducing the need for multiple components.


Sujet(s)
Composés du calcium , Oxydes , Titane , Cires , Composés du calcium/composition chimique , Titane/composition chimique , Oxydes/composition chimique , Cires/composition chimique , Humains , Surveillance de l'environnement/instrumentation , Surveillance de l'environnement/méthodes , Plomb/composition chimique , Plomb/analyse
11.
Front Physiol ; 15: 1398904, 2024.
Article de Anglais | MEDLINE | ID: mdl-38915780

RÉSUMÉ

Arterial compliance (AC) plays a crucial role in vascular aging and cardiovascular disease. The ability to continuously estimate aortic AC or its surrogate, pulse pressure (PP), through wearable devices is highly desirable, given its strong association with daily activities. While the single-site photoplethysmography (PPG)-derived arterial stiffness indices show reasonable correlations with AC, they are susceptible to noise interference, limiting their practical use. To overcome this challenge, our study introduces a noise-resistant indicator of AC: Katz's fractal dimension (KFD) of PPG signals. We showed that KFD integrated the signal complexity arising from compliance changes across a cardiac cycle and vascular structural complexity, thereby decreasing its dependence on individual characteristic points. To assess its capability in measuring AC, we conducted a comprehensive evaluation using both in silico studies with 4374 virtual human data and real-world measurements. In the virtual human studies, KFD demonstrated a strong correlation with AC (r = 0.75), which only experienced a slight decrease to 0.66 at a signal-to-noise ratio of 15dB, surpassing the best PPG-morphology-derived AC measure (r = 0.41) under the same noise condition. In addition, we observed that KFD's sensitivity to AC varied based on the individual's hemodynamic status, which may further enhance the accuracy of AC estimations. These in silico findings were supported by real-world measurements encompassing diverse health conditions. In conclusion, our study suggests that PPG-derived KFD has the potential to continuously and reliably monitor arterial compliance, enabling unobtrusive and wearable assessment of cardiovascular health.

12.
Sensors (Basel) ; 24(12)2024 Jun 16.
Article de Anglais | MEDLINE | ID: mdl-38931686

RÉSUMÉ

Photoplethysmography (PPG) is widely utilized in wearable healthcare devices due to its convenient measurement capabilities. However, the unrestricted behavior of users often introduces artifacts into the PPG signal. As a result, signal processing and quality assessment play a crucial role in ensuring that the information contained in the signal can be effectively acquired and analyzed. Traditionally, researchers have discussed signal quality and processing algorithms separately, with individual algorithms developed to address specific artifacts. In this paper, we propose a quality-aware signal processing mechanism that evaluates incoming PPG signals using the signal quality index (SQI) and selects the appropriate processing method based on the SQI. Unlike conventional processing approaches, our proposed mechanism recommends processing algorithms based on the quality of each signal, offering an alternative option for designing signal processing flows. Furthermore, our mechanism achieves a favorable trade-off between accuracy and energy consumption, which are the key considerations in long-term heart rate monitoring.


Sujet(s)
Algorithmes , Rythme cardiaque , Photopléthysmographie , Traitement du signal assisté par ordinateur , Photopléthysmographie/méthodes , Rythme cardiaque/physiologie , Humains , Monitorage physiologique/méthodes , Dispositifs électroniques portables
13.
Sensors (Basel) ; 24(12)2024 Jun 19.
Article de Anglais | MEDLINE | ID: mdl-38931747

RÉSUMÉ

The development of non-contact techniques for monitoring human vital signs has significant potential to improve patient care in diverse settings. By facilitating easier and more convenient monitoring, these techniques can prevent serious health issues and improve patient outcomes, especially for those unable or unwilling to travel to traditional healthcare environments. This systematic review examines recent advancements in non-contact vital sign monitoring techniques, evaluating publicly available datasets and signal preprocessing methods. Additionally, we identified potential future research directions in this rapidly evolving field.


Sujet(s)
Signes vitaux , Humains , Signes vitaux/physiologie , Monitorage physiologique/méthodes , Traitement du signal assisté par ordinateur
14.
Ann Transl Med ; 12(3): 46, 2024 Jun 10.
Article de Anglais | MEDLINE | ID: mdl-38911566

RÉSUMÉ

Background: Advancements in medical technologies have led to the development of contact-free methods of haemodynamic monitoring such as remote photoplethysmography (rPPG). rPPG uses video cameras to interpret variations in skin colour related to blood flow, which are analysed to generate vital signs readings. rPPG potentially ameliorates problems like fretfulness and fragile skin contact associated with conventional probes in children. While rPPG has been validated in adults, no prior validation has been performed in children. Methods: A two-phased prospective cross-sectional single-centre study was conducted from January to April 2023 to evaluate the feasibility, acceptability, and accuracy of obtaining heart rate (HR), respiratory rate (RR) and oxygen saturation (SpO2) using rPPG in children, compared to the current standard of care. In Phase 1, we recruited patients ≤16 years from the neonatal and paediatric wards. We excluded preterm neonates with gestational age <35 weeks and newborns <24 hours old. The rPPG webcam was positioned 30 cm from the face. After 1 minute of facial scanning, readings generated were compared with pulse oximetry for HR and SpO2, and manual counting for RR. Correlation and Bland-Altman analyses were performed. In Phase 2, we focused on the population in whom there was potential correlation between rPPG and the actual vital signs. Results: Ten neonates and 28 children aged 5 to 16 years were recruited for Phase 1 (765 datapoints). All patients were haemodynamically stable and normothermic. Patients and caregivers showed high acceptability to rPPG. rPPG values were clinically discrepant for children <10 years. For those ≥10 years, moderate correlation was observed for HR, with Spearman's correlation coefficient (Rs) of 0.50 [95% confidence intervals (CI): 0.42, 0.57]. We performed Phase 2 on 23 patients aged 12 to 16 years (559 datapoints). Strong correlation was observed for HR with Rs=0.82 (95% CI: 0.78, 0.85). There was weak correlation for SpO2 and RR (Rs=-0.25 and -0.02, respectively). Conclusions: Our study showed that rPPG is acceptable and feasible for neonates and children aged 5 to 16 years, and HR values in older children aged 12 to 16 years correlated well with the current standard. The rPPG algorithms need to be further refined for younger children, and for obtaining RR and SpO2 in all children. If successful, rPPG will provide a viable contact-free alternative for assessing paediatric vital signs, with potential use in remote monitoring and telemedicine.

15.
Sensors (Basel) ; 24(12)2024 Jun 10.
Article de Anglais | MEDLINE | ID: mdl-38931550

RÉSUMÉ

The remote monitoring of vital signs via wearable devices holds significant potential for alleviating the strain on hospital resources and elder-care facilities. Among the various techniques available, photoplethysmography stands out as particularly promising for assessing vital signs such as heart rate, respiratory rate, oxygen saturation, and blood pressure. Despite the efficacy of this method, many commercially available wearables, bearing Conformité Européenne marks and the approval of the Food and Drug Administration, are often integrated within proprietary, closed data ecosystems and are very expensive. In an effort to democratize access to affordable wearable devices, our research endeavored to develop an open-source photoplethysmographic sensor utilizing off-the-shelf hardware and open-source software components. The primary aim of this investigation was to ascertain whether the combination of off-the-shelf hardware components and open-source software yielded vital-sign measurements (specifically heart rate and respiratory rate) comparable to those obtained from more expensive, commercially endorsed medical devices. Conducted as a prospective, single-center study, the research involved the assessment of fifteen participants for three minutes in four distinct positions, supine, seated, standing, and walking in place. The sensor consisted of four PulseSensors measuring photoplethysmographic signals with green light in reflection mode. Subsequent signal processing utilized various open-source Python packages. The heart rate assessment involved the comparison of three distinct methodologies, while the respiratory rate analysis entailed the evaluation of fifteen different algorithmic combinations. For one-minute average heart rates' determination, the Neurokit process pipeline achieved the best results in a seated position with a Spearman's coefficient of 0.9 and a mean difference of 0.59 BPM. For the respiratory rate, the combined utilization of Neurokit and Charlton algorithms yielded the most favorable outcomes with a Spearman's coefficient of 0.82 and a mean difference of 1.90 BrPM. This research found that off-the-shelf components are able to produce comparable results for heart and respiratory rates to those of commercial and approved medical wearables.


Sujet(s)
Rythme cardiaque , Photopléthysmographie , Fréquence respiratoire , Traitement du signal assisté par ordinateur , Logiciel , Dispositifs électroniques portables , Humains , Photopléthysmographie/méthodes , Photopléthysmographie/instrumentation , Fréquence respiratoire/physiologie , Rythme cardiaque/physiologie , Mâle , Femelle , Monitorage physiologique/méthodes , Monitorage physiologique/instrumentation , Adulte , Études prospectives , Algorithmes
16.
Comput Methods Programs Biomed ; 254: 108283, 2024 Jun 10.
Article de Anglais | MEDLINE | ID: mdl-38901273

RÉSUMÉ

BACKGROUND AND OBJECTIVE: Detection of the dicrotic notch (DN) within a cardiac cycle is essential for assessment of cardiac output, calculation of pulse wave velocity, estimation of left ventricular ejection time, and supporting feature-based machine learning models for noninvasive blood pressure estimation, and hypotension, or hypertension prediction. In this study, we present a new algorithm based on the iterative envelope mean (IEM) method to detect automatically the DN in arterial blood pressure (ABP) and photoplethysmography (PPG) waveforms. METHODS: The algorithm was evaluated on both ABP and PPG waveforms from a large perioperative dataset (MLORD dataset) comprising 17,327 patients. The analysis involved a total of 1,171,288 cardiac cycles for ABP waveforms and 3,424,975 cardiac cycles for PPG waveforms. To evaluate the algorithm's performance, the systolic phase duration (SPD) was employed, which represents the duration from the onset of the systolic phase to the DN in the cardiac cycle. Correlation plots and regression analysis were used to compare the algorithm against marked DN detection, while box plots and Bland-Altman plots were used to compare its performance with both marked DN detection and an established DN detection technique (second derivative). The marking of the DN temporal location was carried out by an experienced researcher using the help of the 'find_peaks' function from the scipy Python package, serving as a reference for the evaluation. The marking was visually validated by both an engineer and an anesthesiologist. The robustness of the algorithm was evaluated as the DN was made less visually distinct across signal-to-noise ratios (SNRs) ranging from -30 dB to -5 dB in both ABP and PPG waveforms. RESULTS: The correlation between SPD estimated by the algorithm and that marked by the researcher is strong for both ABP (R2(87,343) =0.99, p<.001) and PPG (R2(86,764) =0.98, p<.001) waveforms. The algorithm had a lower mean error of DN detection (s): 0.0047 (0.0029) for ABP waveforms and 0.0046 (0.0029) for PPG waveforms, compared to 0.0693 (0.0770) for ABP and 0.0968 (0.0909) for PPG waveforms for the established 2nd derivative method. The algorithm has high rate of detectability of DN detection for SNR of >= -9 dB for ABP waveforms and >= -12 dB for PPG waveforms indicating robust performance in detecting the DN when it is less visibly distinct. CONCLUSION: Our proposed IEM- based algorithm can detect DN in both ABP and PPG waveforms with low computational cost, even in cases where it is not distinctly defined within a cardiac cycle of the waveform ('DN-less signals'). The algorithm can potentially serve as a valuable, fast, and reliable tool for extracting features from ABP and PPG waveforms. It can be especially beneficial in medical applications where DN-based features, such as SPD, diastolic phase duration, and DN amplitude, play a significant role.

17.
JMIR Cancer ; 10: e51210, 2024 Jun 20.
Article de Anglais | MEDLINE | ID: mdl-38900505

RÉSUMÉ

BACKGROUND: Exercise intensity (eg, target heart rate [HR]) is a fundamental component of exercise prescription to elicit health benefits in cancer survivors. Despite the validity of chest-worn monitors, their feasibility in community and unsupervised exercise settings may be challenging. As wearable technology continues to improve, consumer-based wearable sensors may represent an accessible alternative to traditional monitoring, offering additional advantages. OBJECTIVE: The purpose of this study was to examine the agreement between the Polar H10 chest monitor and Fitbit Inspire HR for HR measurement in breast cancer survivors enrolled in the intervention arm of a randomized, pilot exercise trial. METHODS: Participants included breast cancer survivors (N=14; aged 38-72 years) randomized to a 12-week aerobic exercise program. This program consisted of three 60-minute, moderate-intensity walking sessions per week, either in small groups or one-on-one, facilitated by a certified exercise physiologist and held at local community fitness centers. As originally designed, the exercise prescription included 36 supervised sessions at a fitness center. However, due to the COVID-19 pandemic, the number of supervised sessions varied depending on whether participants enrolled before or after March 2020. During each exercise session, HR (in beats per minute) was concurrently measured via a Polar H10 chest monitor and a wrist-worn Fitbit Inspire HR at 5 stages: pre-exercise rest; midpoint of warm-up; midpoint of exercise session; midpoint of cool-down; and postexercise recovery. The exercise physiologist recorded the participant's HR from each device at the midpoint of each stage. HR agreement between the Polar H10 and Fitbit Inspire HR was assessed using Lin concordance correlation coefficient (rc) with a 95% CI. Lin rc ranges from 0 to 1.00, with 0 indicating no concordance and 1.00 indicating perfect concordance. Relative error rates were calculated to examine differences across exercise session stages. RESULTS: Data were available for 200 supervised sessions across the sample (session per participant: mean 13.33, SD 13.7). By exercise session stage, agreement between the Polar H10 monitor and the Fitbit was highest during pre-exercise seated rest (rc=0.76, 95% CI 0.70-0.81) and postexercise seated recovery (rc=0.89, 95% CI 0.86-0.92), followed by the midpoint of exercise (rc=0.63, 95% CI 0.55-0.70) and cool-down (rc=0.68, 95% CI 0.60-0.74). The agreement was lowest during warm-up (rc=0.39, 95% CI 0.27-0.49). Relative error rates ranged from -3.91% to 3.09% and were greatest during warm-up (relative error rate: mean -3.91, SD 11.92%). CONCLUSIONS: The Fitbit overestimated HR during peak exercise intensity, posing risks for overexercising, which may not be safe for breast cancer survivors' fitness levels. While the Fitbit Inspire HR may be used to estimate exercise HR, precautions are needed when considering participant safety and data interpretation. TRIAL REGISTRATION: Clinicaltrials.gov NCT03980626; https://clinicaltrials.gov/study/NCT03980626?term=NCT03980626&rank=1.

18.
Biosensors (Basel) ; 14(5)2024 May 16.
Article de Anglais | MEDLINE | ID: mdl-38785725

RÉSUMÉ

Peripheral artery disease (PAD) is a common circulatory disorder characterized by the accumulation of fats, cholesterol, and other substances in the arteries that restrict blood flow to the extremities, especially the legs. The ankle brachial index (ABI) is a highly reliable and valid non-invasive test for diagnosing PAD. However, the traditional method has limitations. These include the time required, the need for Doppler equipment, the training of clinical staff, and patient discomfort. PWV refers to the speed at which an arterial pressure wave propagates along the arteries, and this speed is conditioned by arterial elasticity and stiffness. To address these limitations, we have developed a system that uses electrocardiogram (ECG) and photoplethysmography (PPG) signals to calculate pulse wave velocity (PWV). We propose determining the ABI based on this calculation. Validation was performed on 22 diabetic patients, and the results demonstrate the accuracy of the system, maintaining a margin of ±0.1 compared with the traditional method. This confirms the correlation between PWV and ABI and positions this technique as a promising alternative to overcome some of the limitations of the conventional method.


Sujet(s)
Index de pression systolique cheville-bras , Photopléthysmographie , Analyse de l'onde de pouls , Humains , Maladie artérielle périphérique/diagnostic , Maladie artérielle périphérique/physiopathologie , Électrocardiographie , Mâle , Femelle , Adulte d'âge moyen
19.
Eur Heart J Digit Health ; 5(3): 335-343, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38774367

RÉSUMÉ

Aims: Elevated blood pressure (BP) is a key risk factor in cardiovascular diseases. However, obtaining reliable and reproducible BP remains a challenge. This study, therefore, aimed to evaluate a novel cuffless wristband, based on photoplethysmography (PPG), for continuous BP monitoring. Methods and results: Predictions by a PPG-guided algorithm were compared to arterial BP measurements (in the sub-clavian artery), obtained during cardiac catheterization. Eligible patients were included and screened based on AAMI/European Society of Hypertension (ESH)/ISO Universal Standard requirements. The machine learning-based BP algorithm required three cuff-based initialization measurements in combination with ∼100 features (signal-derived and patient demographic-based). Ninety-seven patients and 420 samples were included. Mean age, weight, and height were 67.1 years (SD 11.1), 83.4 kg (SD 16.1), and 174 cm (SD 10), respectively. Systolic BP was ≤100 mmHg in 48 samples (11%) and ≥160 mmHg in 106 samples (25%). Diastolic BP was ≤70 mmHg in 222 samples (53%) and ≥85 mmHg in 99 samples (24%). The algorithm showed mean errors of ±3.7 mmHg (SD 4.4 mmHg) and ±2.5 mmHg (SD 3.7 mmHg) for systolic and diastolic BP, respectively. Similar results were observed across all genders and skin colours (Fitzpatrick I-VI). Conclusion: This study provides initial evidence for the accuracy of a PPG-based BP algorithm in combination with a cuffless wristband across a range of BP distributions. This research complies with the AAMI/ESH/ISO Universal Standard, however, further research is required to evaluate the algorithms performance in light of the remaining European Society of Hypertension recommendations. Clinical trial registration: www.clinicaltrials.gov, NCT05566886.

20.
Eur Heart J Digit Health ; 5(3): 379-383, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38774368

RÉSUMÉ

Aims: Invasive haemodynamic monitoring of heart failure (HF) is used to detect deterioration in an early phase thereby preventing hospitalizations. However, this invasive approach is costly and presently lacks widespread accessibility. Hence, there is a pressing need to identify an alternative non-invasive method that is reliable and more readily available. In this pilot study, we investigated the relation between wrist-derived photoplethysmography (PPG) signals and the invasively measured pulmonary capillary wedge pressure (PCWP). Methods and results: Fourteen patients with aortic valve stenosis who underwent transcatheter aortic valve replacement with concomitant right heart catheterization and PPG measurements were included. Six unique features of the PPG signals [heart rate, heart rate variability, systolic amplitude (SA), diastolic amplitude, crest time (CT), and large artery stiffness index (LASI)] were extracted. These features were used to estimate the continuous PCWP values and the categorized PCWP (low < 12 mmHg vs. high ≥ 12 mmHg). All PPG features resulted in regression models that showed low correlations with the invasively measured PCWP. Classification models resulted in higher performances: the model based on the SA and the model based on the LASI both resulted in an area under the curve (AUC) of 0.86 and the model based on the CT resulted in an AUC of 0.72. Conclusion: These results demonstrate the capability to non-invasively classify patients into clinically meaningful categories of PCWP using PPG signals from a wrist-worn wearable device. To enhance and fully explore its potential, the relationship between PPG and PCWP should be further investigated in a larger cohort of HF patients.