Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 29
Filtrer
2.
Am J Cardiol ; 227: 75-82, 2024 Sep 15.
Article de Anglais | MEDLINE | ID: mdl-39059705

RÉSUMÉ

Patients with small aortic annuli (SAAs) are predominantly women. We sought to compare gender-based and propensity-matched outcomes of index transcatheter aortic valve replacement (TAVR) in patients with SAAs. In this retrospective institutional analysis (2012 to 2023), primary stratification was by gender. SAA was defined as an aortic valve annulus diameter <23 mm and the 30-day and 1-year outcomes were compared between the groups. A total of 3,911 patients underwent TAVR. Of those, 661 patients had an SAA, of whom 23.8% were men and 76.2% were women. Propensity matching (1:1) identified 152 pairs. The mean age was 81 years. History of surgical or percutaneous coronary intervention was more prevalent in men (72.4% vs 48%, p <0.001). Men had a higher incidence of postoperative pacemaker implantation (8.6% vs 3.3%, p = 0.05), whereas only women had iliofemoral dissections (4.6% vs 0%, p = 0.007). The rates of moderate (23.0% vs 25.7%) and severe (2.6% vs 0.7%) prosthesis-patient mismatch was not statistically significantly different between the groups (p = 0.364). The 30-day mortality was 0%, whereas the 1-year mortality was 4.3%, with no difference between the groups. An increase in preoperative creatinine was associated with higher risk of death (hazard ratio 1.206, 95% confidence interval 1.025 to 1.418, p = 0.02), whereas gender was not. Kaplan-Meier survival estimates (Log rank, p = 0.768) and cumulative incidence of stroke readmission (p = 0.842) were similar in both groups. In conclusion, the outcomes of TAVR in SAAs do not differ by gender, with safety and efficacy evident in men and women.


Sujet(s)
Sténose aortique , Valve aortique , Score de propension , Remplacement valvulaire aortique par cathéter , Humains , Mâle , Remplacement valvulaire aortique par cathéter/méthodes , Femelle , Études rétrospectives , Sténose aortique/chirurgie , Sujet âgé de 80 ans ou plus , Valve aortique/chirurgie , Facteurs sexuels , Complications postopératoires/épidémiologie , Sujet âgé , Résultat thérapeutique , Taux de survie/tendances , Facteurs de risque
3.
Ann Cardiothorac Surg ; 13(3): 187-205, 2024 May 31.
Article de Anglais | MEDLINE | ID: mdl-38841080

RÉSUMÉ

Background: There is mounting evidence at experienced centers that aortic annular enlargement (AAE) procedures are safe adjuncts to surgical aortic valve replacement (SAVR) that do not increase perioperative morbidity and mortality. This systematic review and meta-analysis aims to assess the impact of AAE procedures on mid-term outcomes after SAVR. Methods: OVID MEDLINE, OVID Embase, and Cochrane Library were searched comprehensively. Comparative studies examining adult patients undergoing SAVR with and without AAE were eligible for inclusion. Studies involving aortic root replacement, Ross procedures, and Ozaki procedures were excluded. The risk of bias was assessed according to Risk Of Bias In Non-randomized Studies of Interventions (ROBINS-I), and the quality of evidence was evaluated according to Grading of Recommendations Assessment, Development and Evaluation (GRADE). Random effects meta-analysis facilitated the quantitative synthesis. Results: A total of 2,765 records were retrieved. After full-text review, 15 eligible studies were identified for data extraction and synthesis. The dataset included a total of 216,654 patients (AAE: 7,967; no AAE: 208,687). Only mid-term outcomes were available. In unmatched and unadjusted studies, perioperative mortality was noted to be higher in the AAE group. However, this difference was not observed in studies with matching or adjusted outcomes. In both the unmatched and unadjusted studies, and the matched and adjusted studies, there were no statistically significant differences identified regarding perioperative stroke, myocardial infarction, or permanent pacemaker implantation. Similarly, there were no statistically significant differences identified in mid-term mortality [hazard ratio (HR), 1.03; 95% confidence interval (CI): 0.95 to 1.11; P=0.49; I2=20% (matched/adjusted studies)], aortic valve reintervention [HR, 0.98; 95% CI: 0.75 to 1.27; P=0.86; I2=0% (matched/adjusted studies)], or heart failure [HR, 1.06; 95% CI: 0.86 to 1.30; P=0.58; I2=25% (matched/adjusted studies)]. Conclusions: SAVR with AAE does not appear to be associated with increased perioperative morbidity or mortality. There is no conclusive indication that AAE enhances mid-term survival, freedom from reoperation, or freedom from heart failure after SAVR.

4.
Am J Cardiol ; 221: 9-18, 2024 06 15.
Article de Anglais | MEDLINE | ID: mdl-38636627

RÉSUMÉ

Patients with small aortic annuli (SAA) pose a challenge in patients undergoing aortic valve replacement because of the potential for prosthesis-patient mismatch (PPM). This study aimed to compare the clinical and hemodynamic outcomes of self-expandable valve (SEV) versus balloon-expandable valve (BEV) transcatheter aortic valve implantation (TAVI) in patients with severe aortic stenosis and SAA. All patients who underwent TAVI for severe native aortic stenosis with a SAA between January 2018 and December 2022 were retrospectively included in the study from a single center. Propensity score matching was performed to balance the baseline characteristics. Bioprosthesis valve dysfunction was based on modified Valve Academic Research Consortium 3 criteria. A total of 1,170 TAVI procedures were performed between 2018 and 2022. After applying the exclusion criteria, 332 patients reported a SAA at computed tomography scan, and the matching created 109 balanced pairs. Echocardiographic data at discharge showed higher mean transvalvular gradients (p <0.001), higher grades of mitral regurgitation (p = 0.029), and lower ejection fraction (p <0.043) in BEVs than SEVs. At follow-up, significant differences favoring the SEV group regarding bioprosthesis valve dysfunction were observed (p = 0.002), especially in terms of severe PPM (p = 0.046) and at least moderate structural valve deterioration (p = 0.040). In conclusion, TAVI in patients with SAA using a BEV was associated with lower valve areas, higher mean pressure gradients, and PPM (including severe) than a SEV. Short- and midterm all-cause and cardiac-related mortality did not differ between the 2 groups. Future randomized studies with extended follow-ups are warranted to validate these outcomes.


Sujet(s)
Sténose aortique , Valve aortique , Bioprothèse , Prothèse valvulaire cardiaque , Hémodynamique , Score de propension , Conception de prothèse , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/méthodes , Mâle , Femelle , Sténose aortique/chirurgie , Sténose aortique/physiopathologie , Hémodynamique/physiologie , Études rétrospectives , Sujet âgé de 80 ans ou plus , Valve aortique/chirurgie , Sujet âgé , Échocardiographie
5.
Heart Lung Circ ; 33(1): 92-98, 2024 Jan.
Article de Anglais | MEDLINE | ID: mdl-38135591

RÉSUMÉ

AIM: The small aortic annulus is a surgical challenge in patients undergoing aortic valve replacement which may lead to patient prosthesis mismatch. Management options include aortic root enlargement, aortic root replacement, and the use of sutureless valves. In this case series, we report our results with aortic root enlargement, sutureless valve implantation, and benchtop modelling of the radial forces exerted. METHODS: Five patients underwent aortic root enlargement and insertion of the Perceval valve as part of the management strategy to enlarge their effective orifice area. We further investigate this strategy with a benchtop model to quantify the radial forces exerted by the Perceval valve on the aortic annulus. Radial and hoop forces on the aortic annulus and inner ring of the Perceval valve were recorded using a Mylar force tester. RESULTS: Five female patients with native annulus between 18mm-20mm underwent root enlargement and insertion of a Perceval S valve. The postoperative course was uncomplicated for all patients except for one who required a permanent pacemaker insertion. Transvalvular pressure gradients remained low at up to 4 years of follow-up (12 mmHg-21 mmHg), with no evidence of paravalvular leak. Benchtop testing demonstrated radial forces exerted at the annulus in all-size Perceval S valves to be within physiological variables, whereas compressive forces required to deform the valves were supraphysiological. CONCLUSIONS: The deployment of a sutureless valve within a surgical enlarged aortic root is a feasible solution in patients with a small aortic root.


Sujet(s)
Sténose aortique , Bioprothèse , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Humains , Femelle , Implantation de valve prothétique cardiaque/méthodes , Aorte thoracique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Sténose aortique/diagnostic , Sténose aortique/chirurgie , Conception de prothèse , Résultat thérapeutique
6.
Expert Rev Cardiovasc Ther ; 21(11): 747-761, 2023.
Article de Anglais | MEDLINE | ID: mdl-37869793

RÉSUMÉ

INTRODUCTION: Small aortic annulus (SAA) poses a challenge in the management of patients with severe aortic stenosis requiring aortic valve replacement - both surgical and transcatheter - since it has been associated with worse clinical outcomes. AREAS COVERED: This review aims to comprehensively summarize the available evidence regarding the management of aortic stenosis in patients with SAA and discuss the current controversies as well as future perspectives in this field. EXPERT OPINION: It is paramount to agree in a common definition for diagnosing and properly treating SAA patients, and for that purpose, multidetector computer tomography is essential. The results of recent trials led to the expansion of transcatheter aortic valve replacement among patients of all the surgical-risk spectrum, and the choice of treatment (transcatheter, surgical) should be based on patient comorbidities, anatomical characteristics, and patient preferences.


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Humains , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Remplacement valvulaire aortique par cathéter/méthodes , Sténose aortique/diagnostic , Sténose aortique/chirurgie , Implantation de valve prothétique cardiaque/méthodes , Résultat thérapeutique , Conception de prothèse
7.
Front Cardiovasc Med ; 10: 1195486, 2023.
Article de Anglais | MEDLINE | ID: mdl-37795479

RÉSUMÉ

Transcatheter aortic valve replacement (TAVR) is a treatment of choice in patients with symptomatic severe aortic valve stenosis (AS) and intermediate-to-high surgical risk. The presence of a small aortic annulus (SAA) has been associated with a higher incidence of prosthesis-patient mismatch (PPM) when surgical aortic valve replacement (sAVR) is performed. TAVR might be a treatment option offering better hemodynamics with a lower incidence of PPM. When a severe AS with a SAA is treated, TAVR-related risk as the coronary obstruction and the annulus rupture, must be also prevented. We present a case of a TAVR in a very small aortic annulus; to our knowledge, this is the smallest native aortic annulus treated percutaneously in a tricuspid stenotic aortic valve with a Self-Expanding Transcatheter Heart Valve (THV) Acurate Neo 2.

8.
Asian Cardiovasc Thorac Ann ; 31(6): 524-532, 2023 Jul.
Article de Anglais | MEDLINE | ID: mdl-37415531

RÉSUMÉ

BACKGROUND: Very few studies provide direct comparisons between aortic root enlargement and sutureless valve implantation in patients with a small aortic annulus who underwent aortic valve replacement. This study aims to provide comparative outcomes between the two in such a subset of patients, through a systematic review and pool analysis. METHODS: The PubMed, Scopus and Embase databases were searched using the appropriate terms. The data from original articles mentioning aortic root enlargement and sutureless valves in a single or comparative study with another group of patients with a small aortic annulus were pooled and analyzed using descriptive statistics. RESULTS: Both cardiopulmonary bypass (68.4 vs. 125.03 min, p < 0.001) and aortic cross-clamp times were significantly shorter in the sutureless valve group, along with a concomitantly higher number of minimally invasive surgeries. The incidence of permanent pacemaker implantation (9.76% vs. 3.16%, p < 0.00001), patient prosthesis mis-match and paravalvular leak was significantly higher in the sutureless valve group. In comparison, the incidence of re-exploration for bleeding was higher in the aortic root enlargement group (5.27% vs. 3.16%, p < 0.02). The two groups had no differences in the duration of hospital stays or mortality. CONCLUSIONS: Sutureless valves demonstrated a comparable hemodynamic outcome with aortic root enlargement in patients with a small aortic annulus. In addition to this, it greatly facilitated minimally invasive surgery. However, the high incidence of pacemaker implantation is still a concern for the widespread recommendation of sutureless valves, especially in young patients with a small aortic annulus.


Sujet(s)
Sténose aortique , Bioprothèse , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Interventions chirurgicales sans suture , Humains , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/étiologie , Implantation de valve prothétique cardiaque/effets indésirables , Aorte thoracique/chirurgie , Résultat thérapeutique , Conception de prothèse , Études rétrospectives , Interventions chirurgicales sans suture/effets indésirables
9.
Indian J Thorac Cardiovasc Surg ; : 1-9, 2023 May 20.
Article de Anglais | MEDLINE | ID: mdl-37359507

RÉSUMÉ

Background: Patient prosthetic mismatch is a serious but avoidable complication of surgical aortic valve replacement (SAVR) complicated by a small aortic annulus. This study aims to compare early and midterm outcomes following aortic valve replacement (AVR) with a mono-leaflet (ML) valve and a bi-leaflet (BL) valve in a small aortic root. Methods and selection: From January 1st, 2017 to December 31st, 2019, 98 patients diagnosed with small aortic root underwent isolated aortic valve replacement with either TTK Chitra valve (Mono-leaflet/ ML group) or St. Jude medical valve (Bi-leaflet/ BL group) of size 17/ 19 mm. Echocardiography was analyzed from medical records and telephonic follow-up. Results: Baseline parameters were comparable. The ML group had 42 patients and the BL group had 56 patients. Aortic cross-clamp time, the incidence of severe patient prosthetic mismatch (p = 0.002) and mean, peak pressure gradients were high in the ML group. Duration of ventilation, intensive care unit (ICU) stay, the incidence of stroke, need for intra-aortic balloon pump, permanent pacemaker, dialysis, and left ventricular mass index in echocardiography were comparable between the two groups postoperatively. There was no early mortality in both group. Survival at the end of 5 years was 57 ± 14.4% in the ML group; 91.8 ± 4% in the BL group (p = 0.005). Univariate and multivariate analysis revealed elderly age as a risk factor for mortality. Conclusion: We conclude that aortic valve replacement without any root widening procedure, using a small-sized mechanical valve provides acceptable early outcomes. Bi-leaflet mechanical valves provide better hemodynamics and survival percentage.

10.
Int Heart J ; 64(3): 487-490, 2023 May 31.
Article de Anglais | MEDLINE | ID: mdl-37197922

RÉSUMÉ

For complex aortic root lesions, the flanged Bentall procedure has more advantages than the traditional one. Here, we report two patients with complex root lesions treated with the flanged Bentall and Cabrol procedure: one was a 25-year-old male with interventricular septal dissection with Behçet's disease, and the other was a 4-year-old female with a very large ascending aortic aneurysm with a small annulus and Loeys-Dietz syndrome. Both patients recovered uneventfully and obtained good short-term results.


Sujet(s)
Maladies de l'aorte , Syndrome de Loeys-Dietz , Mâle , Femelle , Humains , Enfant d'âge préscolaire , Adulte , Aorte thoracique , Résultat thérapeutique , Aorte/imagerie diagnostique , Aorte/chirurgie , Valve aortique
11.
Gen Thorac Cardiovasc Surg ; 71(3): 167-174, 2023 Mar.
Article de Anglais | MEDLINE | ID: mdl-35904726

RÉSUMÉ

OBJECTIVES: This study aimed to evaluate the incidence of patient-prosthesis mismatch (PPM) and degree of left ventricular (LV) mass regression after surgical aortic valve replacement (SAVR) and transcatheter aortic valve replacement (TAVR) in patients with small aortic annulus (defined as annular diameter of ≤ 21 mm). METHODS: We retrospectively analyzed echocardiographic findings in total of 277 patients with aortic stenosis and small aortic annulus (63 underwent SAVR and 214 underwent TAVR) between October 2013 and March 2019. PPM was defined as an effective orifice area index (EOAI) ≤ 0.85 cm2/m2. LV mass regression was evaluated as percentage change in LV mass index (LVMI) from baseline to the 1-year follow-up. RESULTS: The median EOAI before discharge was slightly larger in the TAVR group than in the SAVR group (1.09 vs. 1.07 cm2/m2; P = 0.030). However, the incidence of PPM before discharge (9.4 vs. 12.7%; P = 0.438) and at the 1-year follow-up (11.7 vs. 11.1%; P = 0.901) was similar between groups. Mild or greater paravalvular leakage (PVL) after the procedure was more frequent in the TAVR group (11.7 vs. 0%; P = 0.002). Reduction in LVMI was significantly higher in the SAVR group (19.3 vs. 6.4%; P < 0.001). Multivariate analysis demonstrated that reduction in LVMI was positively associated with higher baseline transaortic pressure gradient (P < 0.001) and higher baseline LVMI (P < 0.001) and negatively associated with older age (P < 0.001) and mild or greater PVL (P < 0.001). CONCLUSIONS: SAVR provides better LV mass regression than TAVR with a comparable rate of PPM in patients with small aortic annulus.


Sujet(s)
Sténose aortique , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Humains , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/méthodes , Implantation de valve prothétique cardiaque/méthodes , Études rétrospectives , Résultat thérapeutique , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Facteurs de risque
12.
Int J Angiol ; 31(2): 120-125, 2022 Jun.
Article de Anglais | MEDLINE | ID: mdl-35833173

RÉSUMÉ

Transcatheter aortic valve replacement has been developed as an emerging technique to treat patients with aortic valve disease. However, safety and outcome data on extremely small transcatheter heart valves (THV) is limited. We aimed to assess hemodynamic profiles and clinical outcome of very small balloon expandable THVs with 20-mm Sapien 3 (SP3). We examined data for all patients who received third-generation SP3 THV at a single hospital. Complications and clinical outcomes were defined based on the VARC-2 criteria. Postoperative prosthesis-patient mismatch (PPM) was defined as indexed effective orifice area (EOA) < 0.85 cm 2 /m 2 . We compared clinical characteristics and outcome between patients with 20-mm ( n = 21), 23-mm ( n = 67), and 26- or 29-mm ( n = 113) sized valves. The 20-mm group included significantly higher number of Asian and female populations with lower body surface area. The baseline CT annular area in the 20-mm group was 316.5 ± 24.9 mm 2 . There was no significant difference between groups in procedural mortality or early safety at 30 days. The higher procedural complication was observed in 20-mm group due to significant differences in minor vascular and bleeding complications. Despite higher post-THV gradients and smaller indexed EOA in 20-mm group, no PPM was observed in 20-mm group. The mortality at 30 days and 1 year in 20-mm group was 4.8% and 16.7%, respectively. The patients who received very small THVs with 20-mm SP3 did not result in PPM and experienced favorable early safety and midterm outcome in our cohort.

13.
J Invasive Cardiol ; 34(6): E433-E441, 2022 06.
Article de Anglais | MEDLINE | ID: mdl-35593541

RÉSUMÉ

BACKGROUND: Patients with small aortic annuli (SAA) are prone to higher post-transcatheter aortic valve replacement (TAVR) transvalvular gradients and development of prosthesis-patient mismatch (PPM). In many patients with SAA, the choice of TAVR valve commonly involves choosing between the 26-mm Medtronic Evolut 2 (ME26) or the 23-mm Edwards Sapien 3 valve (ES23). We compared echocardiographic and clinical outcomes in patients with SAA undergoing TAVR with either valve. METHODS: We queried the Providence St. Joseph Health Society of Thoracic Surgeons/American College of Cardiology Transcatheter Valve Therapy Registry database for patients undergoing TAVR with either the ES23 or ME26 between July 2015 and December 2018 at 11 hospitals. Post-TAVR echocardiographic and clinical results in-hospital, at 1 month, and at 1 year were examined. High gradient (HG) was defined as mean gradient (MG) ≥20 mm Hg. RESULTS: We identified 1162 patients with SAA undergoing TAVR with either the ME26 (n = 233) or ES23 valve (n = 929). Baseline characteristics between groups were similar. At 1 month, the ME26 was associated with a lower MG than the ES23 (7.7 ± 4.7 mm Hg vs 13.1 ± 4.9 mm Hg; P<.001) and moderate or severe PPM (11% and 3% vs 27% and 13%; P<.001). Occurrence of HG at 1 year was lower with the ME26 valve vs the ES23 valve (0% vs 15%; P<.001). In-hospital and follow-up clinical outcomes to 1 year were similar for both groups. CONCLUSION: TAVR in SAA with the ME26 is associated with lower incidence of HG or PPM compared with the ES23. While clinical outcomes at 1 year were similar, the long-term implications of these findings remain unknown.


Sujet(s)
Sténose aortique , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Sténose aortique/diagnostic , Sténose aortique/étiologie , Sténose aortique/chirurgie , Prothèse valvulaire cardiaque/effets indésirables , Humains , Conception de prothèse , Facteurs de risque , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
14.
Eur J Cardiothorac Surg ; 62(3)2022 08 03.
Article de Anglais | MEDLINE | ID: mdl-35380636

RÉSUMÉ

OBJECTIVES: Surgical aortic valve replacement (SAVR) in small annuli carries an elevated risk for the patient-prosthesis mismatch. In this study, we systematically investigated the influence of different implantation techniques including annular enlargement (AE) on the functional result after SAVR in small annuli using a standardized ex vivo model. METHODS: SAVR using the PERIMOUNT Magna Ease® (PME) 21 mm was performed in small porcine aortic roots using 4 implantation techniques: non-everting pledgeted (NE) suture, single interrupted (SI) suture, continuous suture (CS), figure-of-8 (F8) suture, as well as the PME 23 mm after AE using the Nunez method and the NE suture technique (PME23 AE). The effective orifice area (EOA), mean pressure gradient and leakage volume were evaluated using a mock circulation loop in accordance with ISO regulations. RESULTS: Experiments were conducted on 31 porcine aortic roots. PME21 using F8 and PME23 after AE achieved a significantly larger EOA than using NE. PME23 after AE showed a larger EOA than the PME21 using any suture technique, except the F8 [for stroke volume of 74 ml: PME21 NE: 1.68 (1.63-1.72) cm2, PME21 SI: 1.76 (1.68-1.81) cm2 (P = 0.17), PME21 CS: 1.76 (1.65-1.79) cm2 (P = 0.14), PME21 F8: 1.81 (1.70-1.85) cm2 (P = 0.005); PME23 AE: 1.83 (1.73-1.92) cm2 (P < 0.001)]. SI and CS did not result in larger EOA compared with the NE technique. PME21 using SI had a significantly larger leakage volume than using NE and there was no significant difference between other techniques [for stroke volume of 74 ml: PME21 NE: 3.51 (1.85-4.53) ml/stroke, PME21 SI: 6.00 (4.02-7.06) ml/stroke (P < 0.001), PME21 CS: 4.04 (3.60-4.49) ml/stroke (P = 0.10), PME21 F8: 3.16 (1.99-3.62) ml/stroke (P = 0.74), PME23 NE: 2.89 (2.45-4.72) ml/stroke (P = 0.51)]. CONCLUSIONS: The F8 technique with the PME21 achieved a similar EOA as the 1 size larger PME23 using NE after AE. These results suggest that the F8 technique may be an effective surgical modification to improve the haemodynamic result in a small annulus without additional AE.


Sujet(s)
Sténose aortique , Bioprothèse , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Animaux , Valve aortique/chirurgie , Sténose aortique/chirurgie , Implantation de valve prothétique cardiaque/méthodes , Hémodynamique , Conception de prothèse , Techniques de suture , Suidae
15.
Clin Res Cardiol ; 110(12): 1957-1966, 2021 Dec.
Article de Anglais | MEDLINE | ID: mdl-34387736

RÉSUMÉ

BACKGROUND: A small aortic annulus is associated with increased risk of prosthesis-patient mismatch (PPM) after transcatheter aortic valve implantation (TAVI). Whether specific transcatheter heart valve (THV) designs yield superior hemodynamic performance in these small anatomies remains unclear. METHODS: Data from 8411 consecutive patients treated with TAVI from May 2012 to April 2019 at four German centers were retrospectively evaluated. A small aortic annulus was defined as multidetector computed tomography-derived annulus area < 400 mm2. TAVI was performed with a balloon-expanding intra-annular (Sapien-3, n = 288), self-expanding intra-annular (Portico, n = 110), self-expanding supra-annular (Evolut, n = 179 and Acurate-Neo, n = 428) and mechanically expanding infra-annular (Lotus, n = 64) THV according to local practice. PPM was defined as indexed effective orifice area ≤ 0.85cm2/m2. RESULTS: A small annulus was found in 1069 (12.7%) patients. PPM was detected in 38.3% overall with a higher prevalence after implantation of a balloon-expanding intra-annular or mechanically expanding infra-annular THV compared to self-expanding intra- and supra-annular THV. Multivariable analysis linked self-expanding THV (Evolut: Odds ratio [OR] 0.341, Acurate-Neo: OR 0.436, Portico: OR 0.291), postdilatation (OR 0.648) and age (OR 0.968) to lower rates of PPM, while aortic valve calcification was associated with an increased risk (OR 1.001). Paravalvular regurgitation > mild was more frequent after TAVI with self-expanding THV (p = 0.04). CONCLUSION: In this large contemporary multicenter patient population, a substantial number of patients with a small aortic anatomy were left with PPM after TAVI. Self-expanding supra- and intra-annular THV demonstrated superior hemodynamics in these patients at risk, however at the cost of higher rates of residual paravalvular regurgitation.


Sujet(s)
Sténose aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/anatomopathologie , Calcinose/chirurgie , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter/méthodes , Sujet âgé , Sujet âgé de 80 ans ou plus , Valve aortique/chirurgie , Sténose aortique/diagnostic , Calcinose/diagnostic , Femelle , Radioscopie , Humains , Mâle , Tomodensitométrie multidétecteurs , Conception de prothèse , Études rétrospectives , Résultat thérapeutique
16.
Interact Cardiovasc Thorac Surg ; 33(4): 518-524, 2021 10 04.
Article de Anglais | MEDLINE | ID: mdl-34089604

RÉSUMÉ

OBJECTIVES: We investigated the Ozaki procedure using a single interrupted suture technique (SST) and compared this with the standard continuous suture technique (CST) with regard to hydrodynamic valve performance. In addition, both techniques were compared with the native aortic valve (NAV). METHODS: Effective orifice area, mean pressure gradient and leakage volume were evaluated in the NAV as well as after an Ozaki procedure using SST or CST in fresh swine aortic roots using a mock circulation loop. The NAV, SST and CST were evaluated under 4 defined hydrodynamic conditions. RESULTS: Both suture techniques resulted in a similar effective orifice area under all conditions [for stroke volume of 70 ml: SST: 1.50 (1.35-1.87) vs CST: 1.57 (1.41-1.72) cm2, P = 0.8] and there were no significant differences between both suture techniques and the NAV (P > 0.05). Regarding mean pressure gradient, the Ozaki procedure with SST and CST showed no significant differences [7.23 (5.53-8.91) vs 7.04 (6.65-7.60) mmHg, P = 0.72] and there was no significant difference between both suture techniques and the NAV (P > 0.1). In leakage volume, there was no significant difference between SST and CST [4.49 (3.91-4.99) vs CST: 4.23 (3.58-4.87) ml/stroke, P = 0.34]. CONCLUSIONS: The Ozaki procedure with SST performed similarly to that with CST with regard to hydrodynamic performance. Our results suggest that the Ozaki procedure can be performed with SST instead of CST, which may be useful in patients with limited surgical exposure, such as a small annulus.


Sujet(s)
Valve aortique , Prothèse valvulaire cardiaque , Animaux , Aorte/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Humains , Débit systolique , Techniques de suture , Suidae
17.
J Clin Med ; 10(5)2021 Mar 04.
Article de Anglais | MEDLINE | ID: mdl-33806531

RÉSUMÉ

The Trifecta valve has externally mounted leaflets; it differs from classic internally mounted valves (e.g., Carpentier-Edwards [C-E]). We evaluated post-implantation hemodynamics and clinical outcomes of these bioprostheses in small aortic annuli. From January 2015 to April 2019, 490 patients who underwent aortic valve replacement (AVR) were reviewed retrospectively. Altogether, 183 patients received 19 or 21 mm diameter C-E (n = 121) or Trifecta (n = 62) prostheses. To minimize confounding variables, we performed propensity-score matching analysis. The mean transvalvular pressure gradient (TVPG) was significantly lower in the Trifecta than in the C-E group at discharge (12.9 ± 4.8 vs. 15.0 ± 5.3 mmHg, p = 0.044). TVPG change over time was not significantly different between groups (p = 0.357). Left ventricular mass index decreased postoperatively (reduction: C-E, 28.1%; Trifecta, 30.1%, p = 0.879). No late mortality, severe patient-prosthesis mismatch, moderate-to-severe paravalvular leakage, structural valve degeneration, or valve thromboses were observed. Freedom from valve-related events at 3 years were similar for C-E (97.9% ± 2.1%) and Trifecta (97.7% ± 2.2%) patients (log-rank p = 0.993). Bioprosthesis design for small annuli significantly affected TVPG immediately after AVR. However, hemodynamics over time and clinical outcomes did not differ between the two designs.

18.
J Cardiothorac Surg ; 15(1): 174, 2020 Jul 17.
Article de Anglais | MEDLINE | ID: mdl-32680555

RÉSUMÉ

BACKGROUND: Werner's syndrome is an autosomal recessive rare genetic disorder characterized by clinical features suggestive of accelerated aging caused by mutation of the WRN gene. Although some reports exist of aortic valve replacement for aortic stenosis in patients with Werner's syndrome, case using annular patch enlargement for a small aortic annulus are rare. We report herein the rare case of a patient with Werner's syndrome and severe aortic stenosis treated by aortic valve replacement with annular patch enlargement. CASE PRESENTATION: A 55-year-old woman genetically diagnosed with Werner's syndrome suffered from symptomatic severe aortic stenosis with small annulus. Elective aortic valve replacement was performed. Intraoperatively the aortic annulus measured < 16 mm in diameter. Nicks technique for aortic root enlargement using a Hemashield patch was performed and an 18-mm mechanical valve was successfully inserted. After being discharged home her postoperative course was satisfactory for 2 years. CONCLUSIONS: Aortic valve replacement with annular patch enlargement to treat a small aortic annulus in a patient with Werner's syndrome was successful. Treatment strategy must be determined while considering of the patient's age, physical status, and severity of complications.


Sujet(s)
Sténose aortique/diagnostic , Valve aortique , Prothèse valvulaire cardiaque , Syndrome de Werner , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Diagnostic différentiel , Conception d'appareillage , Femelle , Implantation de valve prothétique cardiaque , Humains , Adulte d'âge moyen
19.
Heart Surg Forum ; 23(2): E171-E173, 2020 03 24.
Article de Anglais | MEDLINE | ID: mdl-32364909

RÉSUMÉ

Reconstruction of the aortic root in patients with aortic root aneurysm and small aortic annulus is an intricate surgical procedure. Here, we describe our technique performed in 2 patients, that involved aortic root enlargement with grafting in conjunction with annular implantation of the composite graft with a prosthetic mechanical valve, which allowed us to avoid incompatibility. This novel method offers an alternative combined surgical approach for patients with small aortic annulus and aortic root aneurysm that preserves the structure of the valved conduit at the level of the aortic annulus.


Sujet(s)
Aorte thoracique/chirurgie , Anévrysme de l'aorte thoracique/chirurgie , Valve aortique/chirurgie , Implantation de prothèses vasculaires/méthodes , Implantation de valve prothétique cardiaque/méthodes , Sujet âgé , Aorte thoracique/imagerie diagnostique , Anévrysme de l'aorte thoracique/diagnostic , Valve aortique/imagerie diagnostique , Échocardiographie , Femelle , Humains , Tomodensitométrie
20.
Gen Thorac Cardiovasc Surg ; 68(8): 762-767, 2020 Aug.
Article de Anglais | MEDLINE | ID: mdl-32008187

RÉSUMÉ

OBJECTIVE: At our institution, we actively perform aortic valve neocuspidization (AVNeo) for aortic valve stenosis (AS) with a small annulus. In this report, we aimed to evaluate the midterm outcome of AVNeo for AS with a small annulus. METHODS: From February 2011 to May 2017, we performed AVNeo for AS with a small annulus in 34 patients. Their mean age was 77.0 ± 9.1 years. Preoperative transthoracic echocardiography (TTE) revealed a mean peak pressure gradient average of 84.2 ± 31.1 mmHg. The effective orifice area index (EOAi) was 0.45 ± 0.14 cm2/m2. The mean annulus diameter was 18.4 ± 1.1 mm. Our procedure complies with the three cuspid suturing to the aortic annulus with glutaraldehyde-treated autologous pericardium. RESULTS: There were no conversion to aortic valve replacement and no concomitant annulus enlargement. There were two inhospital mortalities resulting from a noncardiac cause. Three patients underwent reoperation owing to aortic regurgitation (n = 2) and infective endocarditis (n = 1). One patient underwent a pacemaker implantation for complete atrioventricular block. The mean follow-up period was 28.0 ± 22.7 months. Postoperative TTE showed a mean peak pressure gradient average of 18.3 ± 9.4 mmHg and a calculated mean EOAi of 1.18 ± 0.35 cm2/m2. The freedom from reoperation rates were 94.1% and 90.8% at 1 year and 5 years of follow-up, respectively. The overall survival rates were 91.2% and 76.8% at 1 and 5 years of follow-up, respectively. CONCLUSIONS: The midterm outcome of AVNeo for AS with a small annulus was excellent. The long-term outcome and reliability of this procedure must be fully clarified.


Sujet(s)
Sténose aortique/chirurgie , Péricarde/transplantation , Sujet âgé , Sujet âgé de 80 ans ou plus , Sténose aortique/imagerie diagnostique , Survie sans rechute , Échocardiographie , Femelle , Humains , Japon , Mâle , Réintervention
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE