1.
Article de Anglais | MEDLINE | ID: mdl-33612902

RÉSUMÉ

We present the development of a PET insert system for potential simultaneous PET/MR imaging using a 9.4 T small animal MRI scanner to test our system. The detectors of the system adopt a strip-line based multiplexing readout method for SiPM signals. In this readout, multiple SiPM outputs in a row share a common strip-line. The position information about a hit SiPM is encoded in the propagation time difference of the signals arriving at the two ends of the strip-line. The use of strip-lines allows us to place the data acquisition electronics remotely from the detector module to greatly simplify the design of the detector module and minimize the mutual electromagnetic interference. The prototype is comprised of 14 detector modules, each of which consists of an 8x4 LYSO scintillator array (each LYSO crystal is 3x3x10 mm3) coupled to two units of Hamamatsu MPPC arrays (4x4, 3.2 mm pitch) that are mounted on a strip-line board. On the strip-line board, outputs of the 32 SiPMs are routed to 2 strip-lines so that 16 SiPM signals share a strip-line. The detector modules are installed inside a plastic cylindrical supporting structure with an inner and outer diameter of 60 mm and 115 mm, respectively, to fit inside a Bruker BioSpec 9.4 Tesla MR scanner. The axial field of view of the prototype is 25.4 mm. The strip-lines were extended by using 5-meter cables to a sampling data acquisition (DAQ) board placed outside the magnet. The detectors were not shielded in the interest of investigating how they may affect and be affected by the MRI. Experimental tests were conducted to evaluate detection performance, and phantom and animal imaging were carried out to assess the spatial resolution and the MR compatibility of the PET insert. Initial results are encouraging and demonstrate that the prototype insert PET can potentially be used for PET/MR imaging if appropriate shielding will be implemented for minimizing the mutual interference between the PET and MRI systems.

2.
Nucl Instrum Methods Phys Res A ; 830: 119-129, 2016 Sep 11.
Article de Anglais | MEDLINE | ID: mdl-27746514

RÉSUMÉ

A strip-line and waveform sampling based readout is a signal multiplexing method that can efficiently reduce the readout channels while fully exploiting the fast time characteristics of photo-detectors such as the SiPM. We have applied this readout method for SiPM-based time-of-flight (TOF) positron emission tomography (PET) detectors. We have prototyped strip-line boards in which 8 SiPMs (pitch 5.2 mm) are connected by using a single strip-line, and the signals appearing at the ends of the strip-line are acquired by using the DRS4 waveform sampler at a nominal sampling frequency of 1-5 GS/s. Experimental tests using laser and LYSO scintillator are carried out to assess the performance of the strip-line board. Each SiPM position, which is inferred from the arrival time difference of the two signals at the ends of the strip-line, is well identified with 2.6 mm FWHM resolution when the SiPMs are coupled to LYSO crystals and irradiated by a 22Na source. The average energy and coincidence time resolution responding to 511 keV photons are measured to be ~32% and ~510 ps FWHM, respectively, at a 5.0 GS/s DRS4 sampling rate. The results show that the sampling rate can be lowered to 1.5 GS/s without performance degradation. These encouraging initial test results indicate that the strip-line and waveform sampling readout method is applicable for SiPM-based TOF PET development.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE