Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 15.249
Filtrer
1.
Article de Anglais | MEDLINE | ID: mdl-38966509

RÉSUMÉ

Streptococcus canis is an uncommon human pathogen, but documented infections have been mostly associated with exposure to dogs. There are only five documented cases of endocarditis secondary to streptococcus canis, with all cases except one documenting exposure to a canine. We present a 74-year-old male with a history of Type 2 diabetes mellitus, CKD 3, moderate aortic stenosis and remote exposure to agent orange, who was found to have Streptococcus canis native valve endocarditis without exposure to a dog. To the best of our knowledge this case is the first case of endocarditis linked to feline exposure.

2.
Front Cardiovasc Med ; 11: 1370736, 2024.
Article de Anglais | MEDLINE | ID: mdl-38966752

RÉSUMÉ

Rothia dentocariosa is a conditionally pathogenic bacterium that may cause infective endocarditis (IE) in selected patients and give rise to a variety of clinical complications, albeit it is not a common IE pathogen. We present the case of a patient diagnosed with Rothia dentocariosa-associated IE secondary to influenza B and thrombocytopenic purpura. The blood culture revealed Rochebacterium caries, cardiac ultrasound detected vegetation, while brain and spleen abscesses manifested and progressively deteriorated. Despite a suboptimal response to anti-infective therapy, the patient ultimately underwent aortic valve replacement. Discharge from the hospital was achieved upon control of the brain abscess and spleen abscess.

3.
Cureus ; 16(6): e61757, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38975519

RÉSUMÉ

We present a rare instance of aortic root abscess and septic embolic stroke due to Haemophilus parainfluenza in a 75-year-old male patient who had undergone a recent transcatheter aortic valve replacement. The patient initially presented with generalized weakness and altered mental status. Blood cultures grew Haemophilus parainfluenza. Brain imaging showed multiple infarcts with some areas of hemorrhagic conversion. Echocardiography demonstrated an aortic root abscess as well as vegetation on the tricuspid valve. Surgical correction was deemed high risk; hence, management involved intravenous (IV) antibiotics, resulting in the resolution of both symptoms and the abscess.

4.
Eur Heart J ; 2024 Jul 08.
Article de Anglais | MEDLINE | ID: mdl-38976370

RÉSUMÉ

BACKGROUND AND AIMS: Valve interstitial cells (VICs) undergo a transition to intermediate state cells before ultimately transforming into the osteogenic cell population, which is a pivotal cellular process in calcific aortic valve disease (CAVD). Herein, this study successfully delineated the stages of VIC osteogenic transformation and elucidated a novel key regulatory role of lumican (LUM) in this process. METHODS: Single-cell RNA-sequencing (scRNA-seq) from nine human aortic valves was used to characterize the pathological switch process and identify key regulatory factors. The in vitro, ex vivo, in vivo, and double knockout mice were constructed to further unravel the calcification-promoting effect of LUM. Moreover, the multi-omic approaches were employed to analyse the molecular mechanism of LUM in CAVD. RESULTS: ScRNA-seq successfully delineated the process of VIC pathological transformation and highlighted the significance of LUM as a novel molecule in this process. The pro-calcification role of LUM is confirmed on the in vitro, ex vivo, in vivo level, and ApoE-/-//LUM-/- double knockout mice. The LUM induces osteogenesis in VICs via activation of inflammatory pathways and augmentation of cellular glycolysis, resulting in the accumulation of lactate. Subsequent investigation has unveiled a novel LUM driving histone modification, lactylation, which plays a role in facilitating valve calcification. More importantly, this study has identified two specific sites of histone lactylation, namely, H3K14la and H3K9la, which have been found to facilitate the process of calcification. The confirmation of these modification sites' association with the expression of calcific genes Runx2 and BMP2 has been achieved through ChIP-PCR analysis. CONCLUSIONS: The study presents novel findings, being the first to establish the involvement of lumican in mediating H3 histone lactylation, thus facilitating the development of aortic valve calcification. Consequently, lumican would be a promising therapeutic target for intervention in the treatment of CAVD.

5.
Article de Anglais | MEDLINE | ID: mdl-38980286

RÉSUMÉ

This study elucidates the efficacy and outcomes of a minimally invasive aortic valve replacement via a right anterior mini-thoracotomy, emphasizing its potential to minimize surgical trauma and expedite recovery while maintaining procedural integrity comparable to that of a traditional full sternotomy. This video tutorial demonstrates a successful aortic valve replacement procedure using the right anterior mini-thoracotomy approach, characterized by the absence of sutureless valves and specialized instruments. The detailed surgical procedure includes specific steps to optimize visibility and access through strategic incisions and rib dislocations, adhering to "the box principle" for effective exposure of the aortic valve. This video tutorial suggests that a right anterior mini-thoracotomy is a viable, cost-effective alternative to a conventional sternotomy for aortic valve replacement, offering significant patient benefits without compromising long-term valve function or safety. The broader implications for patient selection and surgical techniques highlight the need for meticulous preoperative planning and anatomical assessment to maximize the potential of a right anterior mini-thoracotomy in clinical practice.


Sujet(s)
Valve aortique , Implantation de valve prothétique cardiaque , Interventions chirurgicales mini-invasives , Thoracotomie , Humains , Thoracotomie/méthodes , Interventions chirurgicales mini-invasives/méthodes , Implantation de valve prothétique cardiaque/méthodes , Valve aortique/chirurgie , Mâle , Femelle , Sujet âgé , Sternotomie/méthodes , Résultat thérapeutique , Sténose aortique/chirurgie
6.
Thorac Cardiovasc Surg Rep ; 13(1): e23-e24, 2024 Jan.
Article de Anglais | MEDLINE | ID: mdl-38962470

RÉSUMÉ

Symptoms of papillary fibroelastomas are often related to thromboembolic events but are rarely caused by a mechanical impairment of blood supply by the tumor itself. We describe a case of a papillary fibroelastoma in a 91-year-old female patient leading to a cardiac arrest through intermittent occlusion of the left coronary artery.

7.
Cureus ; 16(6): e61563, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38962646

RÉSUMÉ

The de Winter electrocardiogram (ECG) pattern, marked by upsloping ST depression in leads V2-V6, ST elevation in lead aVR, and tall symmetric T waves, typically indicates left anterior descending artery (LAD) occlusion. Traditionally linked to LAD occlusion, it is rare in severe aortic stenosis and the Bezold-Jarisch reflex (BJR). We report an 83-year-old man with severe aortic stenosis who developed hypotension due to bleeding and exhibited the de Winter ECG pattern. This case highlights how severe aortic stenosis and BJR can lead to significant hemodynamic instability and ischemic ECG changes, resolving after hemodynamic stabilization.

8.
Article de Anglais | MEDLINE | ID: mdl-38965018

RÉSUMÉ

BACKGROUND: Left ventricular (LV) structural and functional changes have been reported in patients with aortic stenosis (AS) who have undergone transcatheter aortic valve implantation (TAVI); however, the relationship between change in LV structure and systolic function and tissue characteristics assessed via cardiovascular magnetic resonance imaging (CMRI) post-TAVI has been not fully elucidated. This study aimed to investigate this relationship in patients with severe AS who underwent TAVI and CMRI. METHODS: In this retrospective study, 65 patients who underwent TAVI and CMRI at the 6-month follow-up were analyzed. The relationship between percent changes in LV end-diastolic volume (LVEDV), LV end-systolic volume (LVESV), LV ejection fraction (LVEF), and LV mass (LVM) (⊿LVEDV, ⊿LVESV, ⊿LVEF, and ⊿LVM) and those in the native T1 value (⊿native T1) was analyzed using a correlation analysis. Moreover, extracellular volume fraction (ECV) value changes were analyzed. RESULTS: The ⊿native T1 significantly decreased from 1292.8 (1269.9-1318.4) ms at pre-TAVI to 1282.3 (1262.6-1310.2) ms at the 6-month follow-up (P = 0.022). A significant positive correlation between ⊿LVEDV, ⊿LVESV, and ⊿LVM and ⊿native T1 (r = 0.351, P = 0.004; r = 0.339, P = 0.006; r = 0.261, P = 0.035, respectively) and a tendency toward a negative correlation between ⊿LVEF and ⊿native T1 (r = -0.237, P = 0.058) were observed. The ECV value increased significantly from 26.7 % (25.3-28.3) to 28.2 % (25.7-30.5) (P = 0.002). CONCLUSIONS: The decrease in native T1 might be associated with LV reverse remodeling. Evaluating structural and functional changes using CMRI may be useful for patient management.

9.
Article de Anglais | MEDLINE | ID: mdl-38984656

RÉSUMÉ

More than mild paravalvular leak (PVL) following transcatheter aortic valve implantation (TAVI) is associated with a twofold increase in all-cause mortality, heart failure hospitalizations, and the need for reintervention. Successfully addressing PVL in TAVIs is more challenging than in surgical valves. The arterial-arterial (A-A) rail technique emerges as a valuable strategy for post-TAVI PVL closure, enhancing success rates by enabling the effective use of lower-profile vascular plug devices. When standard approach is ineffective, generating an A-A loop for post-TAVI PVL closure is probably the most recommended strategy to ensure procedural success.

10.
Article de Anglais | MEDLINE | ID: mdl-38972614

RÉSUMÉ

IMPORTANCE: Guidelines recommend the use of Dobutamine stress echocardiography (DSE) in patients with low-gradient aortic stenosis (AS) and left ventricular ejection fraction (LVEF) <50%. However, a paucity exists in DSE data when LVEF>35%. OBJECTIVE: To examine the diagnostic accuracy of DSE, in patients with low-gradient AS with a wide range of LVEF and to examine the interaction between the diagnostic accuracy of DSE and LVEF. DESIGN, SETTING AND PARTICIPANTS: Patients with mean-gradient<40 mmHg, AVA<1.0 cm2, and stroke volume index≤35 mL/m2 undergoing DSE and Cardiac Computer Tomography (C-CT) were identified from three prospectively collected patient cohorts, and stratified according to LVEF; LVEF<35%, LVEF 35-50% & LVEF>50%. EXPOSURE: DSE and C-CT was performed on patients with low-gradient AS MAIN OUTCOMES AND MEASURES: Severe AS was defined as AVC score ≥2000 AU among men, and ≥1200 AU for women on C-CT. RESULTS: Of 221 patients included in the study, 78 (35%) presented with LVEF<35%, 67 (30%) with LVEF 35-50%, and 76 (34%) with LVEF>50%. Mean-gradient and Vmax during DSE showed significantly diagnostic heterogeneity between LVEF groups, being most precise when LVEF<35% (both AUC=0.90), albeit with optimal thresholds of 30 mmHg & 377 cm/s, and a limited diagnostic yield in patients with LVEF≥35% (AUC=0.67 & 0.66 in LVEF 35-50% and AUC=0.65 & 0.60 in LVEF≥50%). Using guideline thresholds led to a sensitivity/specificity of 49%/84% for all patients with LVEF<50%. CONCLUSION AND RELEVANCE: While DSE is safe and leads to an increase in stroke volume in patients with low-gradient AS regardless of LVEF, the association between DSE gradients and AS severity assessed by C-CT demonstrates important heterogeneity depending on LVEF, with highest accuracy in patients with LVEF<35%.

11.
Front Cardiovasc Med ; 11: 1427930, 2024.
Article de Anglais | MEDLINE | ID: mdl-38957329

RÉSUMÉ

Background: Right anterior mini thoracotomy (RAMT) for aortic valve replacement (AVR) is a minimally invasive procedure that avoids sternotomy. Herein, we report the outcomes of patients who underwent redo-cardiac via a RAMT approach for AVR. Methods: This case series reports the clinical outcomes of 14 consecutive redo operations, done in Calgary (Canada) and Gdansk (Poland) between 2020 and 2023. Primary outcomes were 30-day mortality and disabling stroke. Secondary outcomes included surgical times, hemodynamics, permanent pacemaker implantation (PPM), length of ICU and hospital stay, new post-operative atrial fibrillation (POAF), post-operative blood transfusion, incidence of acute respiratory distress syndrome (ARDS), rate of continuous renal replacement therapy (CRRT) and/or dialysis, and chest tube output in the first 12-hours after surgery. Results: Nine patients were male, and the mean age was 64.36 years. There were no deaths, while one patient had a disabling stroke postoperatively. Mean cardiopulmonary bypass and cross clamp-times were 136 min and 90 min, respectively. Three patients needed a PPM, 3 patients needed blood transfusions, and 2 developed new onset POAF. Median lengths of ICU and hospital stays were 2 and 12 days, respectively. There was no incidence of paravalvular leak greater than trace and the average transvalvular mean gradient was 12.23 mmHg. Conclusion: The number of patients requiring redo-AVR is increasing. Redo-sternotomy may not be feasible for many patients. This study suggests that the RAMT approach is a safe alternative to redo-sternotomy for patients that require an AVR.

12.
Cureus ; 16(4): e58540, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38957831

RÉSUMÉ

The aim of this meta-analysis was to determine the effect of pulmonary hypertension (PH) on survival in patients undergoing transcatheter aortic valve replacement (TAVR). The present study was conducted according to the guidelines of Preferred Reporting of Systematic Review and Meta-Analysis (PRISMA). We conducted a comprehensive search of electronic databases including PubMed/MEDLINE, Embase, Cochrane Library, and Web of Science from January 1, 2015, to March 10, 2024. Outcomes assessed in this meta-analysis included early and late all-cause mortality and cardiovascular mortality. Total 15 studies were integrated into the pooled analysis to assess the impact of PH on outcomes among patients undergoing TAVR, comprising a total sample size of 35,732 individuals. The pooled prevalence of PH stood at 52.57% (n=18,767). Predominantly, the studies were conducted in the United States (n=6), followed by Germany (n=3), with one study each from Japan, Italy, Switzerland, Brazil, Poland, and Australia. Pooled analysis showed that risk of short-term mortality was greater in patients with PH compared to patients without PH (risk ratio (RR): 1.46, 95% CI: 1.19 to 1.80). Risk of long-term mortality was greater in patients with PH (RR: 1.42, 95% CI: 1.29 to 1.55). Risk of cardiovascular mortality was also greater in patients with PH compared to patients without PH (RR: 1.66, 95% CI: 1.36 to 2.02). We advocate for further research to address gaps in understanding different types of PH and their impacts on mortality and cardiovascular outcomes.

13.
Article de Anglais | MEDLINE | ID: mdl-38960283

RÉSUMÉ

OBJECTIVE: The selection of valve prostheses for patients undergoing surgical aortic valve replacement (SAVR) remains controversial. In this study, we compared the long-term outcomes of patients undergoing aortic valve replacement with biological or mechanical aortic valve prostheses. METHODS: We evaluated late results among 5,762 patients aged 45-74 years who underwent biological or mechanical aortic valve replacement with or without concomitant coronary artery bypass from 1989 to 2019 at four medical centers. The Cox proportional hazards model was used to compare late survival; the age-dependent effect of prosthesis type on long-term survival was evaluated by an interaction term between age and prosthesis type. Incidences of stroke, major bleeding, and reoperation on the aortic valve following the index procedure were compared between prosthesis groups. RESULTS: Overall, 61% (n=3,508) of patients received a bioprosthesis. The 30-day mortality rate was 1.7% (n=58) in the bioprosthesis group and 1.5% (n=34) in the mechanical group (P=0.75). During a mean follow-up of 9.0 years, the adjusted risk of mortality was higher in the bioprosthesis group (HR=1.30, P<0.001). The long-term survival benefit associated with mechanical prosthesis persisted until 70 years of age. Bioprosthesis (vs mechanical prosthesis) was associated with a similar risk of stroke (P=0.20), lower risk of major bleeding (P<0.001), and higher risk of reoperation (P<0.001). CONCLUSIONS: Compared to bioprostheses, mechanical aortic valves are associated with a lower adjusted risk of long-term mortality in patients aged 70 years or younger. Patients <70 years old undergoing SAVR should be informed of the potential survival benefit of mechanical valve substitutes.

15.
Eur Heart J ; 2024 Jul 02.
Article de Anglais | MEDLINE | ID: mdl-38953786

RÉSUMÉ

BACKGROUND AND AIMS: Physical activity has proven effective in preventing atherosclerotic cardiovascular disease, but its role in preventing degenerative valvular heart disease (VHD) remains uncertain. This study aimed to explore the dose-response association between moderate to vigorous physical activity (MVPA) volume and the risk of degenerative VHD among middle-aged adults. METHODS: A full week of accelerometer-derived MVPA data from 87 248 UK Biobank participants (median age 63.3, female: 56.9%) between 2013 and 2015 were used for primary analysis. Questionnaire-derived MVPA data from 361 681 UK Biobank participants (median age 57.7, female: 52.7%) between 2006 and 2010 were used for secondary analysis. The primary outcome was the diagnosis of incident degenerative VHD, including aortic valve stenosis (AS), aortic valve regurgitation (AR), and mitral valve regurgitation (MR). The secondary outcome was VHD-related intervention or mortality. RESULTS: In the accelerometer-derived MVPA cohort, 555 incident AS, 201 incident AR, and 655 incident MR occurred during a median follow-up of 8.11 years. Increased MVPA volume showed a steady decline in AS risk and subsequent AS-related intervention or mortality risk, levelling off beyond approximately 300 min/week. In contrast, its association with AR or MR incidence was less apparent. The adjusted rates of AS incidence (95% confidence interval) across MVPA quartiles (Q1-Q4) were 11.60 (10.20, 13.20), 7.82 (6.63, 9.23), 5.74 (4.67, 7.08), and 5.91 (4.73, 7.39) per 10 000 person-years. The corresponding adjusted rates of AS-related intervention or mortality were 4.37 (3.52, 5.43), 2.81 (2.13, 3.71), 1.93 (1.36, 2.75), and 2.14 (1.50, 3.06) per 10 000 person-years, respectively. Aortic valve stenosis risk reduction was also observed with questionnaire-based MVPA data [adjusted absolute difference Q4 vs. Q1: AS incidence, -1.41 (-.67, -2.14) per 10 000 person-years; AS-related intervention or mortality, -.38 (-.04, -.88) per 10 000 person-years]. The beneficial association remained consistent in high-risk populations for AS, including patients with hypertension, obesity, dyslipidaemia, and chronic kidney disease. CONCLUSIONS: Higher MVPA volume was associated with a lower risk of developing AS and subsequent AS-related intervention or mortality. Future research needs to validate these findings in diverse populations with longer durations and repeated periods of activity monitoring.

16.
Ann Med Surg (Lond) ; 86(7): 4005-4014, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38989160

RÉSUMÉ

Background: Aortic valve replacement (AVR) is a common procedure for aortic valve pathologies, particularly in the elderly. While traditional open AVR is established, minimally invasive techniques aim to reduce morbidity and enhance treatment outcomes. The authors' meta-analysis compares these approaches with conventional sternotomy, offering insights into short and long-term mortality and postoperative results. This study provides valuable evidence for informed decision-making between conventional and minimally invasive approaches for AVR. Materials and methods: Till August 2023, PubMed, Embase, and MEDLINE databases were searched for randomized controlled trials (RCT) and propensity score matched (PSM) studies comparing minimally invasive approaches [mini-sternotomy (MS) and right mini-thoracotomy (RMT)] with full sternotomy (FS) for AVR. Various outcomes were analyzed, including mortality rates, bypass and clamp times, length of hospital stay, and complications. Risk ratios (RR) and the weighted mean differences (WMD) with corresponding 95% CIs were calculated using Review Manager. Results: Forty-eight studies were included having 17 269 patients in total. When compared to FS, there was no statistically significant difference in in-hospital mortality in MS (RR:0.80; 95% CI:0.50-1.27; I2=1%; P=0.42) and RMT (RR:0.70; 95% CI:0.36-1.35; I2=0%; P=0.29). FS was also linked with considerably longer cardiopulmonary bypass duration than MS (MD:8.68; 95% CI:5.81-11.56; I2=92%; P=0.00001). The hospital length of stay was determined to be shorter in MS (MD:-0.58; 95% CI:-1.08 to -0.09; I2=89%; P=0.02) with no statistically significant difference in RMT (MD:-0.67; 95% CI:-1.42 to 0.08; I2=84%; P=0.08) when compared to FS. Conclusions: While mortality rates were comparable in minimally invasive approaches and FS, analysis shows that MS, due to fewer respiratory and renal insufficiencies, as well as shorter hospital and ICU stay, may be a safer approach than both RMT and FS.

17.
Ann Med Surg (Lond) ; 86(7): 4060-4074, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38989187

RÉSUMÉ

Background: Aortic stenosis (AS) is a common heart condition categorized into congenital and acquired forms. Transcatheter aortic valve replacement (TAVR) is an innovative method for AS management, and two valve types, self-expanding valves (SEV) and balloon-expandable valves (BEV), are used in TAVR. The objective of this study is to compare the clinical outcomes associated with balloon-expandable and self-expandable valves in transcatheter aortic valve replacement. Methods: The researchers conducted a comprehensive meta-analysis following PRISMA guidelines and AMSTAR-2 tool. The methodology involved a systematic literature search, strict eligibility criteria, unbiased study selection, meticulous data extraction, quality assessment, and rigorous statistical analysis. Results: Our analysis included twenty-six papers and 26 553 patients. BEV exhibited significant advantages over SEV in overall mortality across 21 studies, particularly in perioperative and 30-day assessments. However, no substantial disparities emerged between the two valve types in stroke incidence. BEV demonstrated notable benefits in reducing hospitalization rates across 6 studies and significantly fewer instances of permanent pacemaker implantations across 19 studies, particularly evident in the perioperative setting. Other secondary outcomes like bleeding, acute kidney injury, and myocardial infarction showcased non-significant differences between BEV and SEV. Conclusion: The analysis indicates that BEV may offer benefits in specific aspects of TAVR outcomes, but further research is needed to fully understand the factors influencing patient outcomes and mortality in TAVR procedures.

18.
Oxf Med Case Reports ; 2024(7): omae065, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38989505

RÉSUMÉ

This report discusses a rare case of delayed migration of a Sapien 3 Ultra Resilia (S3UR) valve following transcatheter aortic valve implantation. An 81-year-old Japanese woman had a borderline aortic annular size of 20-23 mm according to the manufacturer's size chart. We chose to implant a smaller S3UR of 20 mm with an 80/20 depth ratio to allow for a second intervention, ensuring good hemodynamics and minimizing paravalvular leak. The patient initially had a favorable outcome despite an accidental 50/50 depth ratio during implantation. On postoperative day 3, the S3UR migrated into the left ventricular outflow tract. Emergency surgical aortic valve replacement was performed to retrieve the migrated valve. Use of the S3UR has led to a growing preference for smaller valve sizes. However, the risk of migration should be recognized. When an accidental 50/50 depth ratio implantation is encountered, post-dilation or second valve implantation should be performed immediately.

19.
Thromb Res ; 241: 109094, 2024 Jul 06.
Article de Anglais | MEDLINE | ID: mdl-38991494

RÉSUMÉ

BACKGROUND: Severe aortic stenosis (sAS) is associated with acquired von Willebrand syndrome (AVWS) by loss of high-molecular-weight multimers (HMWM) of von Willebrand factor (VWF), potentially resulting in perioperative bleeding. Analysis of VWF multimers remains challenging. Recently, the new, rapid Hydragel 5 assay has been developed, using electrophoretic protein separation for dividing VWF-multimers into low (LMWM), intermediate (IMWM), and HMWM, the hemostatically active part of VWF. Here, we evaluated its impact on predicting blood loss in presence of AVWS after surgical aortic valve replacement (SAVR). METHODS: We prospectively examined 52 patients (age: 68 ± 7 years; 54 % male) admitted to SAVR. They were divided in two groups (A: normal VWF, n = 28; B: abnormal VWF, n = 24, defined as VWF-activity/antigen (VWF:Ac/Ag)-ratio < 0.7 and/or HMWM loss). Blood samples and echocardiographic data were collected before, seven days and three months after SAVR. Blood loss and transfusions were recorded. RESULTS: Baseline characteristics and clinical data were similar in both groups. HMWM loss was present in 38.5 % of all patients. HMWM, the VWF:Ac/Ag- and HMWM/(IMWM+LMWM)-ratios were significantly decreased preoperatively in group B but normalized after SAVR. Bleeding, re-thoracotomy and transfusion rates were comparable. HMWM loss was inversely correlated with the peak aortic gradient (Pmax) and positively with the aortic valve area (AVA), while HMWM/(IMWM+LMWM)-ratio negatively correlated with the mean aortic gradient (Pmean). CONCLUSION: HMWM and HMWM/(IMWM+LMWM)-ratio inversely correlate with severity of AS and normalize after SAVR. The Hydragel-5 assay's might be valuable for routine diagnostics to assess bleeding risk and postoperative normalization of AS and VWF abnormalities in SAVR patients.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE