Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 103
Filtrer
1.
Sensors (Basel) ; 24(14)2024 Jul 20.
Article de Anglais | MEDLINE | ID: mdl-39066102

RÉSUMÉ

The aim of this study was to develop a sustainable electromagnetic prototype to detect the interior deterioration of walls in buildings in order to mitigate uncertainty as it is a challenge to observe the interior state of walls without utilising destructive procedures. The method used was experimental, developmental and quantitative in its approach. The inductance, electric current, modulated frequency and power of the electromagnetic field were used to penetrate the constructed specimens, which were built of materials such as concrete, brick, adobe, plaster and fine sand and had walls with a thickness of less than 300 millimetres. The results show that the optimum value of the magnetic field was 0.18 µT, which was sufficient to penetrate 150 mm with densities between 1.0 and 2.4 g/cm3 and porosities between 11 and 60%. The current and wave each had a coefficient of determination R2 = 0.8914, and the average inductance value was 184 µH, which was established with an air core of radius 9.75 cm and with 19 turns with AWG-25 wire. The frequency-modulated signal ranged in the audible zone between 10 and 22 kHz. The presented prototype detects the interior deterioration of the walls of the building, and the signal is reflected on a metallic guide on the opposite side of the wall with a reading error of 5%. The use of this prototype does not represent a risk to the operator or the environment.

2.
J Xray Sci Technol ; 32(4): 1163-1175, 2024.
Article de Anglais | MEDLINE | ID: mdl-38943421

RÉSUMÉ

BACKGROUND: Typical propagation-based X-ray phase contrast imaging (PB-PCI) experiments using polyenergetic sources are tested in very ideal conditions: low-energy spectrum (mainly characteristic X-rays), small thickness and homogeneous materials considered weakly absorbing objects, large object-to-detector distance, long exposure times and non-clinical detector. OBJECTIVE: Explore PB-PCI features using boundary conditions imposed by a low power polychromatic X-ray source (X-ray spectrum without characteristic X-rays), thick and heterogenous materials and a small area imaging detector with high low-detection radiation threshold, elements commonly found in a clinical scenario. METHODS: A PB-PCI setup implemented using a microfocus X-ray source and a dental imaging detector was characterized in terms of different spectra and geometric parameters on the acquired images. Test phantoms containing fibers and homogeneous materials with close attenuation characteristics and animal bone and mixed soft tissues (bio-sample models) were analyzed. Contrast to Noise Ratio (CNR), system spatial resolution and Kerma values were obtained for all images. RESULTS: Phase contrast images showed CNR up to 15% higher than conventional contact images. Moreover, it is better seen when large magnifications (>3) and object-to-detector distances (>13 cm) were used. The influence of the spectrum was not appreciable due to the low efficiency of the detector (thin scintillator screen) at high energies. CONCLUSIONS: Despite the clinical boundary condition used in this work, regarding the X-ray spectrum, thick samples, and detection system, it was possible to acquire phase contrast images of biological samples.


Sujet(s)
Fantômes en imagerie , Animaux , Rayons X , Humains
3.
Sensors (Basel) ; 24(8)2024 Apr 10.
Article de Anglais | MEDLINE | ID: mdl-38676026

RÉSUMÉ

This work presents a novel multielectrode array (MEA) to quantitatively assess the dose enhancement factor (DEF) produced in a medium by embedded nanoparticles. The MEA has 16 nanocrystalline diamond electrodes (in a cell-culture well), and a single-crystal diamond divided into four quadrants for X-ray dosimetry. DEF was assessed in water solutions with up to a 1000 µg/mL concentration of silver, platinum, and gold nanoparticles. The X-ray detectors showed a linear response to radiation dose (r2 ≥ 0.9999). Overall, platinum and gold nanoparticles produced a dose enhancement in the medium (maximum of 1.9 and 3.1, respectively), while silver nanoparticles produced a shielding effect (maximum of 37%), lowering the dose in the medium. This work shows that the novel MEA can be a useful tool in the quantitative assessment of radiation dose enhancement due to nanoparticles. Together with its suitability for cells' exocytosis studies, it proves to be a highly versatile device for several applications.


Sujet(s)
Diamant , Électrodes , Or , Nanoparticules métalliques , Diamant/composition chimique , Nanoparticules métalliques/composition chimique , Or/composition chimique , Argent/composition chimique , Platine/composition chimique , Dose de rayonnement , Humains , Rayons X , Nanoparticules/composition chimique
4.
Animals (Basel) ; 13(24)2023 Dec 07.
Article de Anglais | MEDLINE | ID: mdl-38136810

RÉSUMÉ

Terrorist organizations have compelled security authorities of every nation to make an increasingly significant commitment toward mitigating the risk of mass casualties and severe financial and property damages. As a result, various security measures have been implemented, including the use of advanced equipment and an uptick in intelligence activities. One of the most effective tools that has yielded outstanding results is the use of explosive detection dogs (EDDs). The nature of EDDs demands a high level of sensitivity given the inherent danger and severity of real threat situations that may involve the risk of explosion. Moreover, the operating procedures for EDDs are unique and distinguishable from other forms of detection. We conducted a review to ensure a comprehensive understanding of the subject, highlighting the EDDs' personality profile, selection, training methods, performance, and employment, incorporating insights from diverse fields, conducting an analysis, and presenting a perspective on using EDDs to prevent explosion threats.

5.
6.
Biosensors (Basel) ; 13(8)2023 Aug 17.
Article de Anglais | MEDLINE | ID: mdl-37622912

RÉSUMÉ

Overweight and obesity promote diabetes and heart disease onset. Triglycerides are key biomarkers for cardiovascular disease, strokes, and other health issues. Scientists have devised methods and instruments for the detection of these molecules in liquid samples. In this study, an enzymatic biosensor was developed using an Arduino-based microfluidic platform, wherein a lipolytic enzyme was immobilized on an ethylene-vinyl acetate polymer through physical adsorption. This low-cost optical biosensor employed a spectrophotometric transducer and was assessed in liquid samples to indirectly detect triglycerides and fatty acids using p-nitrophenol as an indicator. The average triglyceride level detected in the conducted experiments was 47.727 mg/dL. The biosensor exhibited a percentage of recovery of 81.12% and a variation coefficient of 0.791%. Furthermore, the biosensor demonstrated the ability to detect triglyceride levels without the need for sample dilution, ranging from 7.6741 mg/dL to 58.835 mg/dL. This study successfully developed an efficient and affordable enzymatic biosensor prototype for triglyceride and fatty acid detection. The lipolytic enzyme immobilization on the polymer substrate provided a stable and reproducible detection system, rendering this biosensor an exciting option for the detection of these molecules.


Sujet(s)
Microfluidique , Infarctus du myocarde , Humains , Adsorption , Acides gras , Polymères
7.
Sensors (Basel) ; 23(12)2023 Jun 07.
Article de Anglais | MEDLINE | ID: mdl-37420570

RÉSUMÉ

Recently, the Gini index detector (GID) has been proposed as an alternative for data-fusion cooperative spectrum sensing, being mostly suitable for channels with line-of-sight or dominant multi-path components. The GID is quite robust against time-varying noise and signal powers, has the constant false-alarm rate property, can outperform many the state-of-the-art robust detectors, and is one of the simplest detectors developed so far. The modified GID (mGID) is devised in this article. It inherits the attractive attributes of the GID, yet with a computational cost far below the GID. Specifically, the time complexity of the mGID obeys approximately the same run-time growth rate of the GID, but has a constant factor approximately 23.4 times smaller. Equivalently, the mGID takes approximately 4% of the computation time spent to calculate the GID test statistic, which brings a huge reduction in the latency of the spectrum sensing process. Moreover, this latency reduction comes with no performance loss with respect to the GID.

8.
J Chromatogr A ; 1699: 463995, 2023 Jun 21.
Article de Anglais | MEDLINE | ID: mdl-37146373

RÉSUMÉ

This work presents a methodology for polycyclic aromatic hydrocarbons (PAHs) trapping from vehicular emissions using an in-tube extraction device (IT-FEx). Trapping selectivity studies were conducted, evaluating the interaction profile between the aromatic compounds and the polymeric phase (composed of polydimethylsiloxane and internal to the IT-FEx devices), as in an aqueous equilibrium system (25 min of sampling), and as in gaseous dynamic phase (30 s of sampling), regarding a qualitative evaluation. The adsorption profiles were similar, with greater affinity for medium-sized PAHs (four aromatic rings) than for the smaller (one to three rings) and larger (five to six rings). The device was attached to a vehicle emission sampler to evaluate the qualitative emission of diesel-powered vehicles. Certain PAHs, such as phenanthrene, fluoranthene, benz[a]anthracene, chrysene, benzo[b]fluoranthene, and benzo[k]fluoranthene, were effectively trapped by the IT-FEx device and detected by the GC-BID analysis. Finally, it was possible to develop a process that combined the steps of sample preparation and instrumental analysis, using the IT-FEx device and applying it to the gaseous matrix in the dynamic phase; until then, little was elucidated regarding the use of this apparatus. This sampling device, combined with analysis by gas chromatography with a barrier ionization discharge detector (GC-BID), is a powerful tool for identifying many compounds from vehicular emissions and does not require solvents in sample preparation.


Sujet(s)
Hydrocarbures aromatiques polycycliques , Hydrocarbures aromatiques polycycliques/analyse , Emissions des véhicules/analyse , Chromatographie en phase gazeuse
9.
Toxicol Rep ; 10: 647-658, 2023.
Article de Anglais | MEDLINE | ID: mdl-37250532

RÉSUMÉ

Total mercury and fatty acids contents were determined in muscles of croaker, snapper, dolphinfish, blue marlin, and shark, from different markets in the Metropolitan District of Quito, Ecuador. Fifty-five samples were collected and analyzed for total mercury using cold vapor atomic fluorescence spectrometry, and the fatty acids were analyzed using gas chromatography equipped with a flame ionization detector. The lowest total mercury levels were found in snapper [0.041 µg·g-1 wet weight (ww)] while blue marlin showed the highest (5.883 µg·g-1 ww). EPA + DHA ranged from 1.0 mg·g-1 in snapper to 2.4 mg·g-1 in shark. A high omega-3/omega-6 ratio was found for all fish types; however, the HQEFA for the benefit-risk ratio was above 1, suggesting an evident risk to human health. Based on our results, consumption of croaker and dolphinfish is recommended up to one serving per week, considering the importance of EFAs intake and avoiding fish with elevated MeHg content. Therefore, Ecuadorian authorities could enhance public standards for seafood safety and develop consumer advice for pregnant women and young children to determine good fish choices or those to avoid.

10.
Crit Rev Anal Chem ; 53(3): 614-633, 2023.
Article de Anglais | MEDLINE | ID: mdl-34510975

RÉSUMÉ

The barrier discharge ionization detector (BID) is one of the latest detection technologies used in gas chromatography (GC). 306 papers from 2012 to 2021 with GC-BID analyses were considered. An overview of the main applications with the BID, considering the trends for the most common analyses, explored compounds, extraction methods, and comparative studies with other detectors is shown. Interest in BID applications has grown, and the number of publications reflects this. Despite having the potential to analyze different compounds, gases are more explored, mainly H2, CH4, and CO. The BID should be further explored for water analysis, as studies show its good performance in larger quantities and at the level of traces. Most of the determinations of these compounds were applied in studies focused on CO2 reduction (by photocatalysis or electro-reduction) and biogas (for CH4). BID is effective for determinations on the order of mmol to µmol. Headspace extraction (HS) is most often applied BID analysis. Reduced dynamic range and nonlinear response to carbon mass are some disadvantages to BID. On the other hand, the BID has a signal-to-noise ratio (S/N) 100 times higher than thermal conductivity detector (TCD) (for inorganic gases and water), a high linear sensitivity for dodecane (LOD less than 1.0 pgC/sec) and other compounds (being able to reach µg/L). Combined with simple extraction methods such as HS, the BID allows quick and simple analysis with great sensitivity, in addition, it is a good alternative for the analysis of inorganic gases and water compared to usual detectors.


Sujet(s)
Gaz , Eau , Carbone , Chromatographie en phase gazeuse/méthodes , Gaz/composition chimique , Méthane/composition chimique , Monoxyde de carbone/composition chimique
11.
Food Chem ; 405(Pt B): 134853, 2023 Mar 30.
Article de Anglais | MEDLINE | ID: mdl-36435108

RÉSUMÉ

Chocolate is widely consumed worldwide and its market grows every year, with emerging demands for new high-quality products. However, this product is susceptible to contamination with polycyclic aromatic hydrocarbons (PAHs), representing a risk for humans. In this study, a methodology for the evaluation of benzo[a]pyrene, benzo[a]anthracene, benzo[b]fluoranthene and chrysene in chocolate by high performance liquid chromatography was validated. The occurrence, dietary exposure, and health risks of 4 PAHs in 38 commercial chocolate samples was investigated. The methodology demonstrated adequate accuracy and precision, with recovery (95.25 %-108.12 %) and relative standard deviation (0.14 %-5.83 %). Benzo[a]pyrene and the ∑4 PAHs concentrations varied between 1.09 and 10.42 µg/kg and 8.38-41.58 µg/kg, respectively. The results of risk assessment suggest low potential health risk for chocolate consumers, considering the margin of exposure (MOE) and the incremental life cancer risk (ILCR) values.


Sujet(s)
Cacaoyer , Chocolat , Hydrocarbures aromatiques polycycliques , Humains , Benzo[a]pyrène , Brésil
12.
Ciênc. anim. bras. (Impr.) ; 24: e, 2023. graf
Article de Anglais | LILACS-Express | VETINDEX | ID: biblio-1513991

RÉSUMÉ

Abstract An estrous-detection patch was used to determine the optimum timing for STAI and the necessity of GnRH at STAI on a 7-day CO-Synch+CIDR protocol. Crossbred beef cows (n=216) were stratified into the following treatment groups: CTRL=TAI (n=67) at 72 h post CIDR removal, or TRT=STAI (n=149) at 72 or 84 h post CIDR removal. All females received GnRH (100 mcg) plus a CIDR on d0, PGF2α, CIDR removal, and an Estrotect estrous-detector patch on d7. At 72 h post-CIDR removal, a patch score was assigned (PS1<50% removed; PS2>50% removed) to all females. Cows in the CTRL group were administered a second GnRH (100 mcg) at 72 h TAI. Cows in the TRT group with PS2 were not administered GnRH. At 84 h, the remaining TRT group cows were given a second PS; cows with PS1 received a GnRH (100 mcg), and cows with PS2 were not administered. Results: The TAI pregnancy rates were similar (P=0.81) between the CTRL (45.6%) and TRT (44.8%) groups. Pregnancy rates tended to be higher (P=0.07) for cows with PS2 (50.3%) than for those with PS1 (29.4%). However, by extending TAI to 84 h in unresponsive cows, 82.0% of TRT cows did not receive a second injection of GnRH at TAI. It was concluded that the estrous detector patches reduced the percentage of cows that required GnRH at TAI without compromising pregnancy rates. The estrous detector patches significantly reduced the number of cows that received a second GnRH injection at TAI.


Resumo Um adesivo de detecção de estro foi usado como ferramenta para determinar o momento ideal para a inseminação artificial em tempo dividido (STAI) e a necessidade de injeção de hormônio liberador de gonadotrofinas (GnRH) no 7º dia do protocolo CO-Sinc + CIDR sem comprometer as taxas de prenhez. As vacas eram cruzadas, multíparas e lactantes (Angus x Charolês, n=216) e foram estratificadas por idades (5,9 2.5 anos), BW (581 67kg), BCS (5,3 0,8; 1-9), intervalo entre partos (78,5 15,5 dias). O grupo de tratamento CTRL = IAT (n=67) foi inseminado após 72 h após a remoção do CIDR; já no grupo tratamento TRT= IATP (n=149) as vacas foram inseminadas 72 ou 84 h após a remoção do CIDR. Todas as fêmeas receberam GnRH (100 mcg I.M.), mais um CIDR (1,38 g de progesterone) no D0, no D7 foi realizado a retirada do CIDR, aplicação de PGF2α (25 mcg I.M.) e colocação do adesivo detector de cio. Após 72 h da remoção do CIDR, uma pontuação foi atribuída ao adesivo (OS1<50% removido; OS2> 50% removido) de todas as fêmeas. As vacas do grupo CTRL receberam a segunda injeção de GnRH (100 mcg I.M.) às 72 h na IAT. Vacas do grupo TRT com OS2 não receberam GnRH. Às 84 h as vacas restantes do grupo TRT receberam um segundo OS, aquelas com OS1 receberam GnRH (100 mcg I.M.) e as vacas com OS2 não receberam GnRH. Amostras de sangue para concentração de progesterona foram coletadas nos D-11 e D-0 para determinar o percentual de vacas ciclando. Os dados foram analisados utilizando-se o Proc Genmod, tendo o tratamento e o técnico de IA como efeitos fixos, o touro como efeito aleatório e o BW, BCS, idade e IBP como covariáveis. Resultados: as taxas de gravidez da IAT foram semelhantes (P= 0,81) entre os grupos CTRL (45,6%) e TRT (44,8%). As taxas de prenhez tenderam a ser maiores (P=0,07) para vacas com OS2 (50,3%) do que para aquelas com OS1 (29,4%). No entanto, ao estender a IAT para 84 horas em vacas não responsivas, 82,0% das vacas TRT não receberam uma segunda aplicação de GnRH na IAT. Concluiu-se que os adesivos detectores de estro reduziram a porcentagem de vacas que necessitaram de GnRH na IAT sem comprometer as taxas de prenhez. Os adesivos de detecção de estro reduziram significativamente o número de vacas que receberam uma segunda injeção de GnRH na IAT.

13.
Phys Med Biol ; 67(21)2022 10 20.
Article de Anglais | MEDLINE | ID: mdl-36179707

RÉSUMÉ

Objective.In cities situated at high-altitude, the measured x-ray spectra are required to calculate the absorbed dose to water in radiobiology and medical dosimetry because of the air-density effect. This work aims to measure, in a high-altitude city, a set of x-ray spectra from an x-ray tube with tungsten anode generated at potentials of the M-series x-ray beams from NIST in the range of 20 and 150 kV as well as other beam qualities that have been characterized and used for dosimetry study in our group called W-series. To also measure some spectra of mammography interest in the energy range of 25 and 35 kV using additional filtration of rhodium (Rh), molybdenum (Mo) and silver (Ag).Approach.A tungsten anode x-ray tube with potential between 10 to and 160 kV was used. A high-purity germanium (HPGe) detector associated with a DSPEC Jr 2.0TMdigital signal processing module has been used for the spectra measurements. Prior the spectra measurements, the HPGe detector has been characterized and calibrated using several radioactive sources. Mainresults.The M80 spectrum was compared to a mathematically filtered beam from Physicalisch Technische Bundesanstalt corresponding to the same potential finding a difference of 0.7% in the average energy. So, the mathematically filtered beam from PTB matches very well our M80 beam. The beams M80, M100 and M120 were also compared with calculations for the corresponding kilovoltage from an executable that calculates x-ray spectra from tungsten anode x-ray tubes in the energy range between 40 to 300 kV called SpekCalc. The SpekCalc reproduces qualitatively the experimental spectra, but not quantitatively, mainly for M100 and M120 beams.Significance.These spectra can be used to simulate the patient dose as well as image quality using Monte Carlo (MC) codes or to evaluate the absorbed dose in dosimetry studies.


Sujet(s)
Germanium , Radiologie , Rhodium , Humains , Rayons X , Tungstène , Molybdène , Argent , Mammographie/méthodes , Méthode de Monte Carlo , Eau
14.
Appl Radiat Isot ; 188: 110399, 2022 Oct.
Article de Anglais | MEDLINE | ID: mdl-35970115

RÉSUMÉ

This paper describes the use of gamma ray spectrometry in the study of rock samples from the Irati Formation, Paraná sedimentary basin, São Paulo State, Brazil. This technique allowed to measure the natural radiation emitted by 40K, as well the radionuclides belonging to the decay series of 238U (eU = 226Ra = 214Bi) and 232Th (eTh = 228Th = 208Tl) which occur in the analyzed samples. Four gamma ray spectrometers have been utilized for comparing the results obtained: a portable sodium iodide [NaI(Tl)] scintillation detector (Digidart), a handheld bismuth germanate oxide (BGO) detector and two bench NaI(Tl) crystals, differing in their geometry (Planar and Well types). This study involved the calibration of the spectrometers, except in the case of the BGO that is factory calibrated. Afterwards, gamma ray analysis was done for 122 rock samples colleted at Partecal Quarry located at Assistência District, Rio Claro city, which have been of interest for the oil and gas sector. For comparison purposes, the obtained datasets were subjected to different statistical tests, including the analysis of variance (ANOVA) that proved to be of great value for checking the differences of the mean concentration values of eU, eTh and K. The results pointed out several factors that affect the gamma ray analysis for the natural radioelements uranium, thorium, and potassium such as the samples size, shape and geometry, detector type, shielding and counting time. These factors are of difficult control in order to get reliable radiometric measurements by this technique.


Sujet(s)
Contrôle des radiations , Uranium , Brésil , Rayons gamma , Contrôle des radiations/méthodes , Spectrométrie gamma/méthodes , Thorium/analyse , Uranium/analyse
15.
Eur Arch Otorhinolaryngol ; 279(12): 5885-5895, 2022 Dec.
Article de Anglais | MEDLINE | ID: mdl-35763084

RÉSUMÉ

PURPOSE: In the present study, a new procedure to perform automatic audiometry using multifrequency Auditory Steady-State Response (ASSR) is proposed. METHODS: The automatic audiometry procedure consists of detecting the presence of multifrequency ASSR in real-time using the sequential test strategy and by adjusting the stimulus intensity independently. The ASSR audiometric thresholds of 18 adult volunteers with normal hearing were determined by automatically (four simultaneous frequencies per ear) at modulation frequencies in the 80 Hz range. The exam time and the difference between ASSR thresholds and pure-tone behavioural hearing thresholds were estimated as performance measures. RESULTS: The results showed that automatic audiometry can reduce the number of intensity levels used to obtain the ASSR threshold by up to 58% when compared to audiometry without using the techniques applied in automatic audiometry. In addition, the average of the difference between ASSR thresholds and Pure-Tone Behavioural Hearing thresholds was around 19 dB, which is similar to the results reported in similar studies. CONCLUSIONS: The audiometric procedure proposed in this study is fully automatic, i.e., does not require any human supervision throughout the exam, and is able to significantly reduce the conventional exam time.


Sujet(s)
Audiométrie électroencéphalographique , Ouïe , Adulte , Humains , Audiométrie tonale/méthodes , Audiométrie électroencéphalographique/méthodes , Seuil auditif/physiologie , Ouïe/physiologie , Bénévoles , Potentiels évoqués auditifs du tronc cérébral/physiologie , Stimulation acoustique
16.
Curr Res Food Sci ; 5: 878-885, 2022.
Article de Anglais | MEDLINE | ID: mdl-35647558

RÉSUMÉ

In this study, the effects of different concentrations of pea protein concentrate (PPC) in the physical properties, porosity features, and oxidative stability of maltodextrin-based spray-dried microparticles containing orange essential oil (OEO, rich in limonene) were evaluated. The use of PPC resulted in spray-dried microparticles with encapsulation efficiencies of about 99 wt%, without visible pores, and relatively high glass transition temperature (66,4 °C) at Aw âˆ¼ 0.3. The nitrogen adsorption and positron annihilation lifetime spectroscopy measurements showed that the increase of PPC concentration from 2.4 to 4.8 wt% (g of PPC/100 g of emulsion) did not affect the porosity features of the microparticles. These results were confirmed by the profiles of OEO retention and limonene oxide production, which were similar for both samples throughout four weeks of storage. Based on these results, we verified that the lower amount of PPC we tested can effectively protect the OEO during storage, showing that a relatively cheaper orange flavor powder can be produced using less protein.

17.
J Tradit Complement Med ; 12(2): 123-130, 2022 Mar.
Article de Anglais | MEDLINE | ID: mdl-35528477

RÉSUMÉ

BACKGROUND AND AIM: Echinodorus macrophyllus (Kunth.) Micheli is popularly used for acute and chronic inflammatory conditions. The anti-inflammatory activity was previously demonstrated for its flavonoid-enriched fractions. The aim of this work assessed the antinociceptive properties of both aqueous extract and its fractions. EXPERIMENTAL PROCEDURE: The antinociceptive activity was determined by acetic acid-induced writhing, formalin test, tail immersion test, hot-plate test, xylene-induced ear edema methods, and the evaluation of its mechanism was performed in the writhing model. The aqueous extract of Echinodorus macrophyllus (AEEm) was fractionated, yielding Fr20, and Fr40. Fr40 composition was determined by HPLC-DAD-ESI-MS. RESULTS AND CONCLUSION: Fr20 (all doses) and Fr40 (100 mg/kg) reduced the nociception in the tail-flick model. Both fractions increased the percentage of maximum possible effect with 25 mg/kg, in the hot-plate assay, at 60 min, while AEEm reduced pain only with 50 and 100 mg/kg. There was a reduction in xylene-edema index, with Fr40 (25 mg/kg), AEEm (50 mg/kg) and Fr20 (50 mg/kg). All doses of AEEm, Fr20, and Fr40 reduced both phases of the formalin model. In the abdominal contortion model, Fr40 presented the highest activity, reducing 96% of contortions and its antinociceptive mechanism was evaluated. The results indicated the involvement of NO and adrenergic activation pathways. The main components of Fr40 are swertisin, swertiajaponin, isoorientin 7,3'-dimethyl ether, swertisin-O-rhamnoside, isoorientin, isovitexin, isovitexin-Orhamnoside, and isovitexin-7-O-glucoside. The aqueous extract of E. macrophyllus leaves and its fractions exhibited significant analgesic effect, mediated through both peripheral and central mechanisms being considered a potentially antinociceptive drug.

18.
Radiol Case Rep ; 17(6): 2058-2062, 2022 Jun.
Article de Anglais | MEDLINE | ID: mdl-35464793

RÉSUMÉ

Double right coronary artery (RCA) is an extremely uncommon anomaly that is mostly detected incidentally in patients undergoing coronary angiography. It can be a benign and isolated anomaly or associated with other congenital abnormalities, mostly other coronary anomalies. Although atherosclerosis and myocardial ischemia have been frequently reported in patients with double RCA, this likely reflects that the patients were evaluated for chest pain rather than the predisposition to atherosclerosis in double RCA. Paralleling the increased awareness of this entity and the availability of non-invasive and cost-effective imaging of the coronary arteries, the diagnosis of double RCA has increased recently. Here, we present a case of double RCA diagnosed by coronary computed tomographic angiography, and provide a mini-review on the demography, anatomic variants, and clinical significance of double RCA.

19.
Phytopathology ; 112(7): 1513-1523, 2022 Jul.
Article de Anglais | MEDLINE | ID: mdl-35050679

RÉSUMÉ

The facultative biotrophic basidiomycete Sporisorium scitamineum causes smut disease in sugarcane. This study applied an assay to identify S. scitamineum candidate effectors (CEs) with plant immunity suppression activities by delivering them into Nicotiana benthamiana cells via the type-three secretion system of Pseudomonas fluorescens EtHAn. Six CEs were individually cloned into the pEDV6 vector and expressed by P. fluorescens EtHAn for translocation into the plant cells. Three CEs (g1052, g3890, and g5159) could suppress pattern-triggered immunity (PTI) responses with high reproducibility in different coinfiltration experiments with P. syringae pv. tomato DC3000. In addition, three CEs (g1052, g4549, and g5159) were also found to be AvrB-induced suppressors of effector-triggered immunity (ETI), demonstrating for the first time that S. scitamineum can defeat both PTI and ETI responses. A transcriptomic analysis at different stages of infection by the smut fungus of three sugarcane cultivars with contrasting responses to the pathogen revealed that suppressors g1052, g3890, g4549, and g5159 were induced at the early stage of infection. By contrast, the two CEs (g2666 and g6610) that did not exhibit suppression activities expressed only at the late stage of infection. Moreover, genomic structures of the CEs and searches for orthologs in other smut species suggested duplication events and further divergence in CEs evolution of S. scitamineum. Thus, the transient assay applied here demonstrated the potential of pEDV6 and P. fluorescens EtHAn as biological tools for identifying plant immune suppressors from S. scitamineum.


Sujet(s)
Basidiomycota , Saccharum , Ustilaginales , Protéines bactériennes/génétique , Systèmes bactériens de sécrétion/métabolisme , Régulation de l'expression des gènes végétaux , Maladies des plantes/microbiologie , Protéines végétales/génétique , Protéines végétales/métabolisme , Reproductibilité des résultats , Saccharum/génétique , Ustilaginales/métabolisme
20.
Dentomaxillofac Radiol ; 51(3): 20210340, 2022 Mar 01.
Article de Anglais | MEDLINE | ID: mdl-34520241

RÉSUMÉ

OBJECTIVES: A systematic review was performed to analyze the current evidence on three-dimensional (3D) computed tomography (CT) superimposition protocols used to assess dentomaxillofacial changes after orthognathic and orthofacial surgery. Accuracy, reproducibility, and efficiency were evaluated. METHODS: The search was divided into Main Search (PubMed, EMBASE, Cochrane Library, LILACS, and SciELO), Grey Literature search (Google Scholar and Open Grey), and Manual search. Thirteen studies were included. Of these, 10 reported data on accuracy, 10 on reproducibility and five on efficiency. Seven proposed or evaluated methods of voxel-based superimposition, three focused on the surface-based technique, one compared surface- and voxel-based superimposition protocols, one used the maximum mutual information algorithm, and one described a landmark-based superimposition method. Cone-beam computed tomography (CBCT) was the most common imaging technique, being used in 10 studies. RESULTS: The accuracy of most methods was high, showing mean differences smaller than voxels' dimensions, ranging between 0.05 and 1.76 mm for translational accuracy, and 0.10-1.09° for rotational accuracy. The overall reproducibility was considered good as demonstrated by the small mean error (range: 0.01-0.26 mm) and high correlation coefficients (range: 0.53-1.00). Timing to complete virtual superimposition techniques ranged between a few seconds up to 40 min. CONCLUSIONS: Voxel-based superimposition protocols presented the highest accuracy and reproducibility. Moreover, superimposition protocols that used automated processes and involved only one software were the most efficient.


Sujet(s)
Chirurgie orthognathique , Protocoles cliniques , Tomodensitométrie à faisceau conique/méthodes , Os de la face , Humains , Imagerie tridimensionnelle/méthodes , Reproductibilité des résultats
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE