1.
Clin Oral Investig ; 28(9): 482, 2024 Aug 12.
Article de Anglais | MEDLINE | ID: mdl-39128981

RÉSUMÉ

OBJECTIVES: To analyze the differences in cusp height on radiographs, establishing proportional relationships between cusp and alveolar bone crest (ABC) measurements. The goal of this study was to develop a correction coefficient by considering this proportion. MATERIALS AND METHODS: Twenty-one artificial teeth, molars and premolars, and bovine ribs were used. Interproximal radiographs were taken with the aid of a positioner. The vertical angles used were: 0°, + 5°, and + 10°, and processed using three spatial resolutions measured in line pairs per mm (lp/mm): 20, 25 and 40. The Perio filter was applied to each image, in addition to the original one. Combinations of angle, resolution, and filter were made. Eighteen images were analyzed by three specialists, resulting in 252 measurements for each evaluator, totaling 756 measurements. RESULTS: The overall variability of the measurements can be explained mainly by the variation in tooth anatomy. The 0° 25 lp/mm Perio filter method was the closest one to the actual clinical scenario for both cusps and ABC. The correction factor managed to explain 71.45% of the errors. CONCLUSIONS: The variation in vertical angulation interferes with cusp and ABC measurements, and the angulation at 0º and spatial resolution of 25 lp/mm showed better results. The use of correction coefficients allowed approaching actual measurement values. CLINICAL RELEVANCE: More accurate ABC height measurements are essential even in radiographic exams that do not meet the standard of excellence because the need to repeat radiographic exams is then eliminated.


Sujet(s)
Processus alvéolaire , Projets pilotes , Animaux , Processus alvéolaire/imagerie diagnostique , Processus alvéolaire/anatomie et histologie , Bovins , Radiographie dentaire , Côtes/imagerie diagnostique , Côtes/anatomie et histologie , Humains , Techniques in vitro , Couronne dentaire/imagerie diagnostique , Couronne dentaire/anatomie et histologie
2.
Clin Oral Investig ; 28(3): 161, 2024 Feb 21.
Article de Anglais | MEDLINE | ID: mdl-38381269

RÉSUMÉ

OBJECTIVE: To assess the impact of enhancement filters on the formation of halo artifacts in radiographs of dental implants obtained with a complementary metal oxide semiconductor (CMOS) system. METHODS: Digital radiographs of dental implants placed in dry human mandibles were processed with the Noise Reduction smoothing filter, as well as the Sharpen 1, Sharpen 4, and Sharpen UM high-pass filters available in the CLINIVIEW™ software (Instrumentarium Dental, Tuusula, Finland). Subjective analysis involved evaluating the left, right, and apical surfaces of each implant for the presence of much, few, or no halo. The objective analysis involved measurement of the halo area using the Trainable Weka Segmentation plugin (ImageJ, National Institutes of Health, Bethesda, MD, USA). Data were analyzed using Friedman's test (subjective analysis) and ANOVA (objective analysis) (α = 5%). RESULTS: In the subjective evaluation, the Sharpen 4 filter produced more radiographs with much halo present, and in the objective evaluation, a bigger halo area when compared to the original images and the Noise Reduction filter for all surfaces (p < 0.05). CONCLUSIONS: When evaluating dental implants, priority should be given to original images and those enhanced with smoothing filters since they exhibit fewer halo artifacts. CLINICAL RELEVANCE: Post-processing tools, such as enhancement filters, may improve the image quality and assist some diagnostic tasks. However, little is known regarding the impact of enhancement filters in halo formation on CMOS systems, which have been increasingly used in dental offices.


Sujet(s)
Artéfacts , Implants dentaires , États-Unis , Humains , Interface os-implant , Oxydes , Semiconducteurs
3.
J Imaging Inform Med ; 37(1): 145-150, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-38343236

RÉSUMÉ

To assess the effect of digital enhancement on the image quality of radiographs obtained with photostimulable phosphor (PSP) plates partially damaged by ambient light. Radiographs of an aluminum step wedge were obtained using the VistaScan and Express systems. Half of the PSP plates was exposed to ambient light for 0, 10, 30, 60, or 90 s before being scanned. The resulting radiographs were exported with and without digital enhancement. Metrics for brightness, contrast, and contrast-to-noise ratio (CNR) were derived, and the ratio of each metric between the exposed-to-light and non-exposed-to-light halves of the radiographs was calculated. The resulting ratios of the radiographs with digital enhancement were subtracted from those without digital enhancement and compared among each other. For the VistaScan system, digital enhancement partially restored brightness, contrast, and CNR. For the Express system, digital enhancement only restored CNR and not the impact of ambient light on brightness and contrast. Specifically, digital enhancement restored 23.48% of brightness for the VistaScan, while percentages below 1% were observed for the Express. Digital enhancement restored 53.25% of image contrast for the VistaScan and 5.79% for the Express; 40.71% of CNR was restored for the VistaScan, and 35% for the Express. Digital enhancement can partially restore the damage caused by ambient light on the brightness and contrast of PSP-based radiographs obtained with the VistaScan, as well as on CNR for the VistaScan and Express systems. The exposure of PSP plates to light can lead to unnecessary retakes and increased patient exposure to X-rays.

4.
Braz. dent. j ; Braz. dent. j;34(4): 150-157, July-Aug. 2023. tab, graf
Article de Anglais | LILACS-Express | LILACS, BBO - Ondontologie | ID: biblio-1520332

RÉSUMÉ

Abstract This study aimed to assess the influence of the file format on the image quality parameters (image noise, brightness, and uniformity) of periapical radiographs acquired with different digital systems. Radiographic images of an acrylic phantom were acquired with two digital systems - Digora Toto and Express, and exported into five different file formats - TIFF, BMP, DICOM, PNG, and JPEG. Image noise, image brightness (mean of gray values), and image uniformity (standard deviation of gray values) were evaluated in all images. A two-way analysis of variance with Tukey's test as a post-hoc test was used to compare the results, considering the file formats and radiographic systems as the studied factors. A significance level of 5% was adopted for all analyses. The DICOM image file format presented lower image noise, higher brightness (higher mean gray values), and greater image uniformity (p<0.001) than the other file formats, which did not differ from each other for both digital radiography systems (p>0.05). The Express system revealed lower image noise and greater image uniformity than the Digora Toto system regardless of the image file format (p<0.001). Moreover, the Express showed higher brightness than the Digora Toto for all image file formats (p<0.001), except for the DICOM image file format, which did not significantly differ between the digital radiography systems tested (p>0.05). The DICOM image file format showed lower image noise, higher brightness, and greater image uniformity than the other file formats (TIFF, BMP, PNG, and JPEG) in both digital radiography systems tested.


Resumo Este estudo teve como objetivo avaliar a influência do formato do arquivo nos parâmetros de qualidade de imagem (ruído de imagem, brilho e uniformidade) de radiografias periapicais adquiridas com diferentes sistemas digitais. As imagens radiográficas de um fantoma de acrílico foram adquiridas com dois sistemas digitais - Digora Toto e Express, e exportadas em cinco formatos de arquivo diferentes - TIFF, BMP, DICOM, PNG e JPEG. O ruído da imagem, o brilho da imagem (média dos valores de cinza) e a uniformidade da imagem (desvio padrão dos valores de cinza) foram avaliados em todas as imagens. A análise de variância (ANOVA) bidirecional com o teste post-hoc de Tukey foi aplicada para comparar os resultados, considerando os formatos de arquivo e os sistemas radiográficos como os fatores estudados. Um nível de significância de 5% foi adotado para todas as análises. O formato de arquivo de imagem DICOM apresentou menor ruído de imagem, maior brilho (maiores valores médios de cinza) e maior uniformidade de imagem (p<0,001) do que os outros formatos de arquivo, que não diferiram entre si para ambos os sistemas de radiografia digital (p>0,05). O sistema Express apresentou menor ruído de imagem e maior uniformidade de imagem que o sistema Digora Toto, independentemente do formato do arquivo de imagem (p<0,001). Além disso, o Express mostrou maior brilho do que o Digora Toto para todos os formatos de arquivo de imagem (p<0,001), exceto para o formato de arquivo de imagem DICOM, que não diferiu significativamente entre os sistemas de radiografia digital testados (p>0,05). O formato de arquivo de imagem DICOM mostrou menor ruído de imagem, maior brilho e maior uniformidade de imagem do que os outros formatos de arquivo (TIFF, BMP, PNG e JPEG) em ambos os sistemas de radiografia digital testados.

5.
Medisan ; 27(4)ago. 2023.
Article de Espagnol | LILACS, CUMED | ID: biblio-1514569

RÉSUMÉ

Durante las últimas décadas el proceso de obtención de imágenes médicas digitales ha avanzado tecnológicamente, de tal modo que estas se han vuelto indispensables en el reconocimiento de numerosas enfermedades y en la aplicación de diferentes terapéuticas; sin embargo, la implementación de la radiología digital constituye un reto para los profesionales de esta rama que no posean una completa preparación, por lo que es necesario desarrollar estrategias coherentes para facilitar su uso. En este trabajo se ofrecen algunas consideraciones teóricas sobre la radiografía digital como medio diagnóstico, lo cual supone un cambio en el ejercicio de los profesionales de esta especialidad, quienes requieren actualizar sus conocimientos en relación con esta técnica, con el fin de perfeccionar su desempeño y establecer diagnósticos certeros que conduzcan a tratamientos eficaces, y así lograr el bienestar y la calidad de vida de la población.


During the last decades the process of obtaining digital medical images has advanced technologically, in such a way that they have become indispensable in the recognition of numerous diseases and in the application of different treatments; however, the implementation of digital radiography constitutes a challenge for professionals in this branch who do not have a complete training, so it is necessary to develop coherent strategies to facilitate its use. This paper offers some theoretical considerations about digital radiography as a diagnostic means, which implies a change in the practice of professionals in this specialty, who need to update their knowledge in relation to this technique, in order to get better their performance and establish accurate diagnoses that lead to effective treatments, and thus achieve the welfare and quality of life in the population.

6.
Int. j. morphol ; 41(4): 1101-1106, ago. 2023. ilus, tab
Article de Espagnol | LILACS | ID: biblio-1514325

RÉSUMÉ

La investigación tuvo como objetivo determinar la influencia de la morfología externa de la raíz de primeros premolares superiores en la existencia de sobreestimación radiográfica durante la preparación para poste. Con este fin se realizó un estudio transversal in vitro, donde 60 premolares superiores uniradiculares fueron instrumentadas con fresas Gates Glidden y Pesso de calibre 1, 2 y 3. Seguidamente se obtuvieron imágenes radiográficas digitales de cada pieza dentaria mediante un aparato posicionador a una distancia constante en sentido vestíbulo lingual, asimismo se realizaron imágenes tomográficas volumétricas de las muestras. En ambas técnicas imagenológicas se midió el espesor a mesial y distal de las piezas. La sobreestimación fue calculada mediante la diferencia de la medida tomográfica menos la radiográfica. Los resultados indicaron que en ambas paredes radiculares hubo diferencia significativa entre las medidas radiográficas y tomográficas (p<0,05), encontrándose en la pared distal diferencias altamente significativas (p<0,001); además se evidenció que la sobreestimación radiográfica fue mayor en la pared distal. El estudio concluyó que existe sobreestimación radiográfica en premolares superiores durante la preparación para poste de un 20,42 % en promedio, siendo la pared distal la estructura que presenta mayor sobreestimación.


SUMMARY: he investigation´s objective was to determine the influence of external morphology of the root of upper first premolars in the existence of radiographic overestimation during preparation for post. An in vitro cross-sectional study was carried out, where 60 single-rooted upper premolars were instrumented with burs. Gates Glidden and Pesso of caliber 1, 2 and 3, then, digital radiographic images of each dental piece were obtained by means of a positioning device at a constant distance in the buccolingual direction; volumetric tomographic images of the samples were also performed. In both imaging techniques, the mesial and distal thickness of the pieces was measured. The overestimation was calculated by the difference of the tomographic measurement minus the radiographic one. The results indicated that in both root walls there was a significant difference between the radiographic and tomographic measurements (p<0.05), with highly significant differences being found in the distal wall (p<0.001); In addition, it was evidenced that the radiographic overestimation was greater in the distal wall. The study concluded that there is radiographic overestimation in upper premolars during post preparation of 20.42% on average, with the distal wall being the structure that presents the greatest overestimation.


Sujet(s)
Humains , Prémolaire/imagerie diagnostique , Préparation de dent , Cavité pulpaire de la dent/imagerie diagnostique , Tomodensitométrie à faisceau conique , Prémolaire/anatomie et histologie , Amélioration d'image radiographique , Études transversales , Restauration coronoradiculaire , Préparation de canal radiculaire , Cavité pulpaire de la dent/anatomie et histologie
7.
Article de Espagnol | LILACS-Express | LILACS | ID: biblio-1559919

RÉSUMÉ

Se presenta el caso de una paciente femenina de 52 años, raza blanca, enfermera de profesión, con antecedentes patológicos personales de hipertensión arterial compensada y tratamiento regular. Manifestó dolor en el hombro derecho y se remitió del Servicio de Ortopedia a la consulta de Medicina Natural y Tradicional del Hospital Clínico Quirúrgico "Lucía Íñiguez Landín". Dos años atrás le habían diagnosticado bursitis subacromial calcificada y había recibido varios tratamientos, pero sin mejoría. Se le corroboró el diagnóstico mediante radiografía digital y ultrasonido. El tratamiento con acupuntura redujo el tamaño de las calcificaciones y alivió los síntomas. La novedad del caso radica en la pertinencia del uso de la acupuntura en el tratamiento de esta patología.


It is presented the case of a female patient of 52 years, white skin, nurse by profession, with a personal pathological history of compensated arterial hypertension and regular treatment. She showed pain in the right shoulder and was referred to the Natural and Traditional Medicine clinic of the "Lucía Íñiguez Landín" Clinical Surgical Hospital. For two years she had been diagnosed with calcific subacromial bursitis and had received several treatments, but without obtaining improvement. The diagnosis was confirmed by digital radiography and ultrasound. Acupuncture treatment reduced the size of calcifications and alleviated symptoms. The novelty of the case lies in the relevance of the use of acupuncture in the treatment of this pathology.

8.
BMC Oral Health ; 23(1): 221, 2023 04 17.
Article de Anglais | MEDLINE | ID: mdl-37069535

RÉSUMÉ

BACKGROUND: External root resorption (ERR) has a multifactorial etiology and is difficult to diagnose, which means that is continues to be of research interest. This work mainly aims to determine whether external root resorption can be differentially detected in root-filled versus non-endodontically treated teeth using digital periapical radiography (DPR) and cone-beam computed tomography (CBCT). METHODS: The Checklist for Reporting In-vitro Studies (CRIS) guidelines were followed throughout this study. This experiment highlights the preparation and generation of standardized synthetic teeth measured on three-dimensional records converted into Digital Imaging and Communication on Medicine (DICOM) file format. Twelve replicate maxillary incisors were randomized into two groups: (G1) six non-endodontically treated, and (G2) six endodontically treated teeth. In both groups, actual tooth lengths of all specimens were measured and compared with measurements obtained using DPR and CBCT. Simulated ERR lesions [0.12, 0.18, 0.20 mm × 0.5 mm depth in the mesial, distal and palatal apical regions] were created progressively, radiographic images were recorded, and 24 DPRs and 96 CBCTs were obtained in total. Eight blinded, previously calibrated researchers made a total of 1920 measurements (using Horos Software). Data were analyzed using the Shapiro-Wilk, ANOVA, Kruskal-Wallis and Wilcoxon rank post-hoc tests [Bonferroni correction in multiple comparison tests (p < 0.05)]. RESULTS: ICC values for intra- and inter-examiner agreement were appropriate. DPR overestimated ERR detection compared to the actual and CBCT measurements [Mean diff = 0.765 and 0.768, respectively]. CBCT diagnosis of ERR lesions in specimens without root canal treatment was significantly more accurate than DPR diagnoses on both non-endodontically and endodontically-treated specimens [p = 0.044; p = 0.037, respectively]. There was an 18.5% reduction in sensitivity in all DPR diagnoses made on endodontic teeth versus those made on non-endodontically treated teeth. For the smallest ERR lesions, this sensitivity was even more marked, with 27.8 and 25% less sensitivity, respectively. CONCLUSIONS: The results of this study highlight that both CBCT and DPR are good diagnostic methods for ERR. Nevertheless, root canal filling material influences diagnostic capability in ERR. The clinical significance was that the presence of intracanal material reduces the detection and diagnosis of ERR by DPR in teeth with root canal treatment.


Sujet(s)
Produits d'obturation des canaux radiculaires , Rhizalyse , Humains , Tomodensitométrie à faisceau conique/méthodes , Radiographie numérisée dentaire/méthodes , Produits d'obturation des canaux radiculaires/usage thérapeutique , Traitement de canal radiculaire/méthodes , Rhizalyse/imagerie diagnostique , Incisive/imagerie diagnostique
9.
Braz. dent. j ; Braz. dent. j;34(1): 39-44, Jan.-Feb. 2023. tab, graf
Article de Anglais | LILACS-Express | LILACS, BBO - Ondontologie | ID: biblio-1420574

RÉSUMÉ

Abstract The study aimed to assess the influence of excessive use of a photostimulable phosphor plate (PSP) on the density, image noise, and contrast of radiographs. For that, radiographs of an acrylic block were acquired with a PSP of the Express intraoral system to assess the density and image noise. Initially, five images were obtained and exported (first group). After 400 exposures to X-rays and scannings of PSP, other five images were obtained and exported (second group). The same procedure was done after 800 (third group), 1200 (fourth group), 1600 (fifth group), and 2000 acquisitions (sixth group), resulting in 30 images to be evaluated. The mean and standard deviation of the gray values were calculated for the images using the ImageJ software. For contrast analysis, radiographs of an aluminum step-wedge were acquired with a new PSP following the same acquisition intervals. The percentage of contrast variation was calculated. Another two unused PSP receptors were employed to evaluate the method's reproducibility. The comparison of the results among the acquisition groups was performed with one-way Analysis of Variance (α=0.05). Intraclass Correlation Coefficient (ICC) assessed the reproducibility of the receptors. Image noise did not differ among the groups (p>0.05). There was a slight increase in density after 400 acquisitions and a slight difference in contrast for all acquisition groups without a pattern of increase or decrease (p<0.05). ICC showed excellent reliability for the methods. Therefore, excessive PSP use slightly affected the radiograph's density and contrast.


Resumo Objetivou-se avaliar a influência do uso excessivo de uma placa de fósforo fotoestimulável (PSP) na densidade, ruído e contraste das radiografias. Foram adquiridas radiografias de um bloco de acrílico com uma PSP do sistema intraoral Express para avaliar a densidade e o ruído da imagem. Inicialmente, cinco imagens foram obtidas e exportadas (primeiro grupo). Após 400 exposições aos raios X e escaneamentos, outras cinco imagens foram obtidas e exportadas (segundo grupo). O mesmo procedimento foi feito após 800 (terceiro grupo), 1200 (quarto grupo), 1600 (quinto grupo) e 2000 aquisições (sexto grupo), resultando em 30 imagens a serem avaliadas. A média e o desvio padrão dos valores de cinza foram calculados para as imagens usando o software ImageJ. Para análise de contraste, foram adquiridas radiografias de uma escala de alumínio com uma nova PSP seguindo os mesmos intervalos de aquisição. A porcentagem de variação do contraste foi calculada. Outras duas PSP sem uso prévio foram utilizadas para avaliar a reprodutibilidade dos métodos. A comparação dos resultados entre os grupos de aquisição foi realizada pela Análise de Variância one-way (α=0,05). O Coeficiente de Correlação Intraclasse (ICC) avaliou a reprodutibilidade dos receptores. O ruído da imagem não diferiu entre os grupos (p>0,05). Houve um leve aumento na densidade após 400 aquisições e uma pequena diferença no contraste para todos os grupos de aquisição sem padrão de aumento ou diminuição (p<0,05). O ICC mostrou excelente confiabilidade para os métodos. Portanto, o uso excessivo da PSP afetou levemente a densidade e o contraste radiográfico.

10.
Oral Radiol ; 39(1): 53-58, 2023 01.
Article de Anglais | MEDLINE | ID: mdl-35218461

RÉSUMÉ

OBJECTIVE: To evaluate whether the automatic exposure compensation in the presence of high-density materials can affect the measurement of alveolar bone level. METHODS: Thirty regions of seven dry skulls and six mandibles were radiographed with and without a high-density material, using two digital radiographic technologies: photostimulable phosphor plate (PSP, Digora Optime) and sensor (CMOS, Digora Toto), totaling 120 images. The distances from the cement-enamel junction to the alveolar bone crest were measured using cone-beam computed tomography (CBCT) images to represent the reference standard. The same measurements of alveolar bone level and the average of the pixel values of the image were evaluated on the radiographs. Paired t test compared the average pixel values and alveolar bone-level measurements between images with and without high-density material. One-way analysis of variance compared the difference between radiographic and CBCT measurements (α = 0.05). RESULTS: The high-density material reduced the pixel values in PSP (p = 0.002) and CMOS (p < 0.001) technologies, demonstrating the AEC functioning in both technologies. There was no difference in bone-level measurements between the images without and with the high-density material for both technologies (p ≥ 0.091), or between the tomographic and radiographic measurements (p ≥ 0.319). CONCLUSION: In the presence of high-density material, the automatic exposure compensation reduces the average pixel values of the images (i.e., images get darker), but does not influence the radiographic measurements of alveolar bone level.


Sujet(s)
Processus alvéolaire , Radiographie numérisée dentaire , Radiographie numérisée dentaire/méthodes , Processus alvéolaire/imagerie diagnostique , Tomodensitométrie à faisceau conique , Mandibule/imagerie diagnostique
11.
Acta odontol. Colomb. (En linea) ; 13(1): 26-39, 20230000. ilus, ilus, tab, tab
Article de Espagnol | LILACS | ID: biblio-1425208

RÉSUMÉ

Objetivo: establecer la relación entre el diagnóstico histopatológico de sacos foliculares de terceros molares y la medida radiográfca estandarizada en radiografía panorámica digital. Métodos: se llevó a cabo un estudio descriptivo en el que se incluyeron 28 sacos foliculares de terceros molares. Dos observadores midieron la radiolucidez pericoronal en radiografías panorámicas digitales usando un método estandarizado y se calculó el índice de correlación intraclase. Se estableció un diagnóstico radiográfco según la medida del saco, con <2.5 mm como el límite para sacos foliculares normales. Dicho diagnóstico fue comparado con el respectivo diagnóstico histopatológico. Se calculó sensibilidad y especifcidad; se aplicó la prueba de chi-cuadrado, exacta de Fisher y, fnalmente, el índice Kappa. Resultados: se obtuvo un alto grado de acuerdo entre los observadores. La prueba radiográfca tuvo una baja sensibilidad (0.27) y especifcidad (0.6) y no se encontró diferencia estadísticamente signifcativa entre estos. Conclusiones: la ausencia de hallazgos radiográfcos no implica ausencia de enfermedad. Además, no se puede establecer relación entre la presencia de quistes dentígeros y radiolucidez ≥ 2.5 mm en radiografía panorámica digital.


Objective: To establish the relationship between the histopathological diagnosis of follicular sacs of third molars and the standardized radiographic measurement in digital panoramic radiography. Methods: This was a descriptive study in which 28 follicular sacs of third molars were included. In digital panoramic radiographs two observers measured the pericoronal radiolucency using a standardized method and the intraclass correlation index was calculated. A radiographic diagnosis was established according to the size of the sac, with <2.5mm being the limit for normal follicular sacs. This diagnosis was compared with the respective histopathological diagnosis. Sensitivity and specifcity were calculated; the chi-square test, Fisher's exact test and fnally the Kappa index were applied. Results: A high degree of agreement was obtained among the observers. The radiographic test had a low sensitivity (0.27) and specifcity (0.6) and no statistically signifcant diference was found between these. Conclusions: The absence of radiographic fndings does not imply absence of disease, furthermore, no relationship can be established between the presence of dentigerous cysts and radiolucency ≥ 2.5 mm in digital panoramic radiography.


Sujet(s)
Humains , Adulte , Kyste dentigère , Dent de sagesse , Anatomopathologie , Radiographie panoramique , Kystes
12.
Odovtos (En línea) ; 24(3)dic. 2022.
Article de Anglais | LILACS, SaludCR | ID: biblio-1406166

RÉSUMÉ

Abstract The aim of this study was to assess the use of digital dental radiology in Brazil, by focusing on the use of image receptors, imaging exams and digital image enhancement tools, also assessing the methods of professional image transfer. Questionnaires were distributed in person on dental meetings and digitally via messaging (WhatsApp®) and mailings list. The sample of this cross-sectional study consisted of 478 questionnaires. Most participants were woman (n=315, 65.9%), with average age of 33.8±9.2 years. Descriptive and frequency analysis was performed. Chi-square and Fisher's exact tests were used (α=0.05). Most dentists worked at shared dental clinics (34.7%) and use digital image receptors (51.1%), but a representative percentage (48.9%) still exclusively use radiographic films. Photostimulable phosphor plate is the most used digital image receptor. Among extraoral exams, panoramic radiography (PAN) is the most used. Regarding dental specialties, oral radiologists and oral and maxillofacial surgeons mostly use cone-beam computed tomography (p<0.001). Most dentists who use digital systems make use of digital image enhancement tools (87.8%), mainly contrast, zoom, brightness and measurements. The most common method of professional image transfer (professional-professional and professional-patiens) is by email, with few dentists using online app and social media (26%). Therefore, while most Brazilian dentists use digital imaging systems, a significant percentage still exclusively use radiographic films. The most extraoral imaging exams used is PAN. Regarding image enhancement tools, brightness and contrast adjustments, zoom and measurements are the most applied. Finally, dentists generally use email for professional image transfer.


Resumen El objetivo de este estudio fue evaluar uso de la radiología dental digital en Brasil, centrándose en uso de receptores de imagen, exámenes de imágenes y herramientas de mejora de imagen digital, evaluando también los métodos de transferencia de imagen profesional. Cuestionarios se distribuyeron de forma presencial en reuniones odontológicas y de forma digital a través de mensajería (WhatsApp®) y lista de correo. Muestra de este estudio transversal estuvo compuesta por 478 cuestionarios. Mayoría de los participantes eran mujeres (n=315, 65,9%), con edad promedio de 33,8±9,2 años. Se realizó un análisis descriptivo y de frecuencias. Se utilizaron las pruebas Chi-cuadrado y exacta de Fisher (α=0,05). La mayoría de los odontólogos trabajaban en clínicas dentales compartidas (34,7%) y utilizan receptores de imágenes digitales (51,1%), pero un porcentaje representativo (48,9%) todavía utiliza exclusivamente películas radiográficas. Placa de fósforo fotoestimulable es el receptor de imagen digital más utilizado. Entre los exámenes extraorales, la radiografía panorámica (PAN) es la más utilizada. En cuanto a las especialidades odontológicas, los radiólogos orales y los cirujanos orales y maxilofaciales utilizan mayoritariamente la tomografía computarizada de haz cónico (p<0,001). Mayoría de los odontólogos que utilizan sistemas digitales utilizan herramientas de mejora de imagen digital (87,8%), principalmente contraste, zoom, brillo y medidas. Método más común de transferencia de imágenes profesionales (profesional-profesional y profesional-pacientes) es por correo electrónico, con pocos dentistas que utilizan aplicaciones en línea y redes sociales (26%). Por lo tanto, mientras que la mayoría de dentistas brasileños utilizan sistemas de imágenes digitales, un porcentaje significativo aún utiliza exclusivamente películas radiográficas. Examen de imagen extraoral más utilizado es el PAN. En cuanto a las herramientas de mejora de imagen, los ajustes de brillo y contraste, el zoom y las medidas son las más aplicadas. Finalmente, los dentistas generalmente usan el correo electrónico para la transferencia de imágenes profesionales.


Sujet(s)
Amélioration d'image radiographique/tendances , Systèmes d'information de radiologie , Brésil , Imagerie diagnostique
13.
Clin Oral Investig ; 26(7): 4743-4752, 2022 Jul.
Article de Anglais | MEDLINE | ID: mdl-35267096

RÉSUMÉ

OBJECTIVES: To evaluate the influence of digital filters of intraoral radiographic systems on the diagnosis of simulated internal and external root resorptions and image quality. MATERIALS AND METHODS: Internal root resorption (IRR) and external root resorption (ERR) were simulated in 34 teeth. For image acquisition, two radiographic systems were used: Digora Toto and VistaScan. All filters available in these systems were applied. Three observers scored the detection of root resorptions in a 5-point scale. The noise and the contrast-to-noise ratio (CNR) were calculated. The area under ROC curve, sensitivity, specificity, and accuracy were obtained. One-way ANOVA with Tukey's post hoc tests compared the diagnostic values, noise, and CNR between the filters (α = 0.05). RESULTS: For ERR, there were no significant differences in diagnostic values between the filters tested for both systems. For IRR, Original and Noise Reduction filters presented higher sensitivity than the Sharpen2 filter for images from Digora Toto, with no differences between the other groups. For VistaScan, there were no significant differences of diagnostic values between the groups studied. Noise values differed among the filters of both systems. The CNR of the filters differed only for the bone region for Digora Toto, while for VistaScan, both tooth and bone regions differed. CONCLUSIONS: Despite promoting changes in pixel intensities and affecting the noise level of the radiographic images, the digital filters of Digora Toto and VistaScan systems do not affect the diagnosis of internal or external root resorptions. CLINICAL RELEVANCE: Digital filters are common tools in digital radiographic systems and may be used by the professional without impairment in root resorptions diagnosis.


Sujet(s)
Rhizalyse , Humains , Courbe ROC , Radiographie numérisée dentaire/méthodes , Rhizalyse/imagerie diagnostique , Racine dentaire
14.
J Digit Imaging ; 35(3): 654-659, 2022 06.
Article de Anglais | MEDLINE | ID: mdl-35166971

RÉSUMÉ

To evaluate the diagnostic accuracy of caries and periapical lesions on a monitor with and without DICOM part 14: grayscale standard display function (DICOM-GSDF) calibration under different ambient light conditions. Forty digital bitewing radiographs were selected, with or without radiographic images of carious lesions and forty digital periapical radiographs with or without periapical lesions were selected from archives of the Radiology Department at the University Hospital of the Federal University of Sergipe. The gold standard radiographic images were determined through consensus between two radiologists with more than 15 and 30 years of experience. The selected radiographs were evaluated on a LG LED monitor with and without DICOM-GSDF calibration under different ambient light conditions: Lx1 (low ambient lighting), Lx2 (moderate ambient lighting) and Lx3 (high ambient lighting). Kappa (Kw) values determined that evaluator 1 showed almost perfect agreement for all devices, while evaluator 2 presented a substantial agreement for all devices. Monitors with and without DICOM-GSDF calibration have similar accuracy values. The three ambient light conditions analyzed have similar accuracy and can be used for caries lesions diagnosis (p > 0.05); however, the best diagnostic accuracy of periapical lesions was found in Lx 2. The displays with and without DICOM-GSDF calibration studied in this research have similar accuracy and can be used to evaluate digital radiographs without changing the diagnostic capacity. The different ambient lighting conditions did not influence the evaluation of caries lesions. The best diagnostic accuracy of periapical lesions was found in moderate ambient lighting.


Sujet(s)
Susceptibilité à la carie dentaire , Radiographie numérisée dentaire , Calibrage , Humains , Éclairage
15.
BMC Med Imaging ; 22(1): 4, 2022 01 05.
Article de Anglais | MEDLINE | ID: mdl-34983424

RÉSUMÉ

BACKGROUND: This study aimed to investigate the effect of automatic exposure compensation (AEC) of intraoral radiographic systems on the gray values of dental tissues in images acquired with or without high-density material in the exposed region using different exposure times and kilovoltages. The influence of the distance of the high-density material was also investigated. METHODS: Radiographs from the molar region of two mandibles were obtained using the RVG 6100 and the Express systems, operating at 60 and 70 kV and 0.06, 0.10, and 0.16 s. Subsequently, a titanium implant was inserted in the premolar's socket and other images were acquired. Using the ImageJ software, two regions of interest were determined on the enamel, coronary dentine, root dentine, and pulp of the first and second molars to obtain their gray values. RESULTS: In the RVG 6100, the implant did not affect the gray values (p > 0.05); the increase in kV decreased it in all tissues (p < 0.05), and the exposure time affected only the root dentine and pulp. In the Express, only enamel and coronary dentine values changed (p < 0.05), decreasing with the implant presence and/or with the increase in exposure factors. The distance of the implant did not affect the results (p > 0.05). CONCLUSIONS: AEC's performance varies between the radiographic systems. Its effect on the gray values depends not only on the presence or absence of high-density material but also on the kV and exposure time used.


Sujet(s)
Traitement d'image par ordinateur/méthodes , Radiographie numérisée dentaire/méthodes , Émail dentaire/imagerie diagnostique , Pulpe dentaire/imagerie diagnostique , Dentine/imagerie diagnostique , Humains , Mandibule/imagerie diagnostique
16.
Dentomaxillofac Radiol ; 51(4): 20210314, 2022 May 01.
Article de Anglais | MEDLINE | ID: mdl-34767483

RÉSUMÉ

OBJECTIVES: This study aimed to evaluate the impact of enhancement filters in detecting small simulated internal root resorptions (IRR). METHODS:: Forty-two extracted human teeth were sectioned, connected, and stored in a dry human jaw and X-rayed with photostimulable phosphor plates (PSPs), composing the control group (CG). In the middle-third of the root canals, IRR lesions were simulated using Da Silveira protocol. Later, the specimens were X-rayed to create the test group (TG). All images acquired were exported with seven enhancement filters plus the original image. Three examiners used a five-point Likert scale to evaluate the images regarding the presence/absence of IRR. Diagnostic efficacy was assessed from sensitivity and specificity results. Comparison among filters was performed by using receiver operating characteristic (ROC) curve analysis. RESULTS:: Moderate values of Kappa interexaminer (0.403-0.620) and high values of Kappa intraexaminer (0.757-0.915) were observed. The best performance occurred in the CG (p < 0.05). Original images presented the greatest sensitivity and area under the ROC curve (0.595-0.750), while the Endo filter presented the greatest specificity (0.952). Inversion and Pseudo-3D images produced the greatest doubt in the diagnosis, significant for CG with the Pseudo-3D filter (p < 0.05). CONCLUSIONS:: The Original and 'Endo' filters should be chosen as it offers greater diagnostic ability and allows more confidence during the evaluation.


Sujet(s)
Rhizalyse , Humains , Courbe ROC , Radiographie , Radiographie numérisée dentaire/méthodes , Rhizalyse/imagerie diagnostique , Sensibilité et spécificité
17.
Dentomaxillofac Radiol ; 51(4): 20210404, 2022 May 01.
Article de Anglais | MEDLINE | ID: mdl-34860568

RÉSUMÉ

OBJECTIVES: To assess the dynamic range and enhancement ability of radiographs acquired with contemporary digital systems. METHODS: Five repeated periapical radiographs of human mandibles with an aluminium step-wedge were acquired using two sensor-based and three photostimulable phosphor plate-based systems and an X-ray unit at ten exposure times 0.020, 0.032, 0.063, 0.080, 0.100, 0.200, 0.320, 0.400, 0.500, and 0.630 s. All images had their brightness and contrast enhanced by two experienced oral and maxillofacial radiologists in consensus and were exported as both the original and enhanced file formats. Mean grey values were obtained from the aluminium steps and tabulated with their corresponding thicknesses for each exposure time, digital radiographic system, and file format. Images with saturated steps were excluded and the mean grey values from the remaining images were averaged to assess image brightness and the angular coefficient of the linear trendlines was generated from the relationship between mean grey values and their corresponding aluminium thicknesses to assess image contrast. Brightness and contrast values were compared using two-way ANOVA with post-hoc Tukey (α = 0.05). RESULTS: Photostimulable phosphor plate-based digital radiographic systems had a broader dynamic range. Longer exposure times produced original images with lower brightness and variable contrast (p < 0.05). Subjective enhancement significantly increased or reduced brightness and/or contrast in some systems (p < 0.05). CONCLUSIONS: Contemporary digital radiographic systems present different dynamic ranges and exposure-related brightness and contrast. Image enhancement may be a valuable tool at slightly suboptimal exposure times.


Sujet(s)
Aluminium , Radiographie numérisée dentaire , Humains , Mandibule , Amélioration d'image radiographique/méthodes , Radiographie numérisée dentaire/méthodes
18.
Oral Radiol ; 38(4): 452-458, 2022 10.
Article de Anglais | MEDLINE | ID: mdl-34626307

RÉSUMÉ

OBJECTIVE: To evaluate the influence of the file format of digital periapical radiographs on the diagnosis of vertical root fracture (VRF). STUDY DESIGN: Periapical radiographic images of 34 single-rooted teeth-19 with VRF, and 15 without VRF were acquired using two digital systems-Digora Toto, and Digora Optime, and exported into four different file formats-TIFF, BMP, PNG, and JPEG, totaling 272 radiographs. The radiographs were assessed by five examiners for the detection of VRF, using a 5-point scale (1-definitely absent; 2-probably absent; 3-uncertain; 4-probably present; 5-definitely present). Diagnostic values of area under the ROC curve, specificity, and sensitivity for the diagnosis of VRF were calculated. The results were compared by two-way Analysis of Variance with post hoc Tukey's test. The intra- and inter-examiner agreements were measured by the Kappa test. The significance level was set at 5% for all analyses. RESULTS: The values of intra-examiner agreement varied from moderate (0.56) to almost perfect (0.81), while the values of inter-examiner agreement varied from fair (0.29) to moderate (0.60). The image file format did not influence the diagnostic values for VRF for any of the radiographic systems tested (p > 0.05). Digora Toto had significantly greater values of area under the ROC curve than Digora Optime for all file formats (p = 0.001). CONCLUSION: The image file format of periapical radiographs does not influence the diagnosis of VRF, regardless of the digital radiography system.


Sujet(s)
Fractures dentaires , Humains , Quinoléinium, composés , Radiographie , Radiographie numérisée dentaire/méthodes , Thiazoles , Fractures dentaires/imagerie diagnostique , Racine dentaire/imagerie diagnostique
19.
Oral Radiol ; 38(3): 356-362, 2022 07.
Article de Anglais | MEDLINE | ID: mdl-34529235

RÉSUMÉ

OBJECTIVES: To investigate the performance of radiographic systems with automatic exposure compensation (AEC) on the caries diagnosis in images acquired with different exposure parameters and in the presence of high-density material. Also, the image quality was assessed. METHODS: Forty posterior teeth (80 proximal surfaces) were radiographed using a phosphor plate and a CMOS system. Images were acquired with different exposure times (0.06, 0.10 and 0.16 s) and kilovoltages (60 and 70kVp), in the absence and presence of high-density material in the X-rayed region (control and high-density groups). Five radiologists assessed the caries using a 5-point scale. Diagnostic values were compared using two-way ANOVA. RESULTS: For both radiographic systems, there were no significant differences in the area under the ROC curve (0.60-0.73), sensitivity (0.79-0.87) and specificity (0.29-0.48) between the control and high-density groups, exposure times or kilovoltages (p > 0.05). For image quality, scores assigned to the control and high-density groups were similar in each exposure protocol in both systems. CONCLUSIONS: The presence of high-density material, exposure time and kilovoltage did not affect the caries diagnosis in any of the systems tested. It is recommended to use protocols with lower doses to reduce the patient's exposure.


Sujet(s)
Susceptibilité à la carie dentaire , Radiographie numérisée dentaire , Humains , Biais de l'observateur , Courbe ROC , Radiographie , Radiographie numérisée dentaire/méthodes
20.
Oral Radiol ; 38(2): 234-239, 2022 04.
Article de Anglais | MEDLINE | ID: mdl-34195932

RÉSUMÉ

OBJECTIVE: To evaluate the diagnostic efficacy of the combined assessment of the original radiographic image with the Invert or Emboss digital enhancement filters in periapical radiographs obtained with different horizontal projection angles in the detection of simulated dental root fracture. MATERIALS AND METHODS: Thirty-four single-rooted teeth were selected, out of which 17 teeth were subjected to root fracture. Each tooth was individually placed in an empty socket of a dry human maxilla or mandible and X-rayed following the paralleling technique at three horizontal projections: mesial, right angle, distal. Then, the Invert and Emboss enhancement filters were applied. Five examiners independently evaluated all the images and rated the fractures using a 5-point scale. Weighted kappa test assessed the intra- and interexaminer agreements. Diagnostic values were calculated and the areas under the receiver operating characteristic curve (AUC) were compared using two-way ANOVA with Tukey test as post hoc (α = 0.05). RESULTS: The inter- and intraexaminer agreement ranged from moderate to almost perfect and from substantial to almost perfect, respectively. Diagnostic values were considerably high for all conditions with no significant difference between the AUC values (p > 0.05). CONCLUSIONS: The combined use of the original radiographic image with the Invert or Emboss digital enhancement filters in periapical radiographs obtained with different projection angles did not influence the detection of simulated dental root fracture.


Sujet(s)
Radiographie numérisée dentaire , Dent , Tomodensitométrie à faisceau conique , Humains , Radiographie , Radiographie numérisée dentaire/méthodes , Racine dentaire/imagerie diagnostique