Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 100
Filtrer
1.
Curr Urol ; 18(2): 155-158, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-39176290

RÉSUMÉ

Urinary leak is one of the most significant complications after partial nephrectomy. In case of persistent urine leaks, placement of a ureteral stent is effective but not always sufficient. This study included 5 patients with persistent urinary leak after partial nephrectomy. The patients underwent flexible ureteroscopy wherein we identified the damaged calyx. Subsequently, we performed percutaneous puncture targeting the distal end of the endoscope at this calyx and installed a nephrostomy tube. Then, the endoscope was removed, and the ureter was drained with a stent. Ureteral stenting ensures elimination of urinary leak in most patients after partial nephrectomy. In patients with persistent urinary leak, retrograde endoscopic percutaneous drainage of the pelvicalyceal system is the method of choice because it allows for rapid and effective treatment of urinary fistulas.

2.
BMC Urol ; 24(1): 149, 2024 Jul 18.
Article de Anglais | MEDLINE | ID: mdl-39026274

RÉSUMÉ

OBJECTIVES: To compare the clinical efficacy and safety of single-use and reusable digital flexible ureteroscopy for the treatment of lower pole stones. METHODS: We enrolled 135 patients underwent reusable flexible ureteroscopy (FURS) and 78 patients underwent single-use digital FURS. Demographic, clinical variables, anatomical parameters of the lower calyx and perioperative indicators were compared in the two groups. RESULTS: Thirty-six patients in the infundibuloureter angle (IPA) < 45° subgroup had a mini-percutaneous nephrolithotomy (mini-PCNL), including 25 patients in the reusable FURS group and 11 patients in the single-use FURS group. The demographic and clinical variables in the two FURS groups were comparable. There was no statistical difference in the success rate of stone searching (P > 0.05). In terms of the success rate of lithotripsy, there was also no statistical difference in the IPA ≥ 45° subgroup (P > 0.05), whereas single-use FURS was superior in the IPA < 45° subgroup (χ2 = 6.513, P = 0.011). The length of the working fiber in the reusable FURS and single-use FURS groups was 3.20 ± 0.68 mm and 1.75 ± 0.47 mm, respectively (t = 18.297, P < 0.05). The use of a stone basket in the reusable FURS (31/135, 23.0%) was significantly higher than that in the single-use FURS (8/78, 10.3%) (χ2 = 5.336, P = 0.021). Compared with the reusable FURS group, the single-use FURS group had shorter operation times (P < 0.05) and higher stone-free rate (SFR) (χ2 = 4.230, P = 0.040). There was no statistical difference in the intraoperative transfer of mini-PCNL and postoperative complications between the two groups (P > 0.05). CONCLUSIONS: Single-use and reusable FURS are alternative methods for removal of lower pole stones (i.e., 2 cm or less). Single-use FURS has a high success rate of lithotripsy, shorter operation time, and high stone-free rate.


Sujet(s)
Réutilisation de matériel , Calculs rénaux , Urétéroscopes , Urétéroscopie , Humains , Urétéroscopie/méthodes , Urétéroscopie/instrumentation , Mâle , Femelle , Études rétrospectives , Calculs rénaux/chirurgie , Adulte d'âge moyen , Adulte , Études cas-témoins , Résultat thérapeutique , Conception d'appareillage , Matériel jetable , Sujet âgé
3.
Trials ; 25(1): 455, 2024 Jul 04.
Article de Anglais | MEDLINE | ID: mdl-38965611

RÉSUMÉ

BACKGROUND: Lithiasis is a common and recurrent disease. Flexible ureteroscopy (fURS) is the cornerstone of laser treatment of kidney stones. Kidney stones destruction requires its laser pulverization into small fragments in order to remove them through the ureter or improve their spontaneous expulsion along the urinary tract. However, most of the time, all the micro-fragments and dust created cannot be extracted using our surgical tools and may stay intra-renally at the end of the procedure. Adjuvant treatments (such as forced diuresis, inversion or mechanical pressure) were previously described to improve the expulsion of stone fragments after extra-corporeal shock wave lithotripsy. Nevertheless, the impact of adjuvant treatment after fURS remains unclear and mainly theoretical. OBJECTIVE: The primary objective is to show that the injection of 40 mg of furosemide in slow intravenous during 10 min, after the procedure, increases the stone-free rate 3 months after a fURS for destruction of kidney stones with laser. METHODS/DESIGN: The study will be a two-parallel group randomized, controlled, multicentric trial with a blinding evaluation. Nine French departments of urology will participate. Patients will be randomized in 2 groups: the experimental group (injection of 40 mg of furosemide at the end of the surgery) and a control one (usual care). Patients will be followed up for 3 months (± 2 weeks) after the surgery. Then, we will perform a low dose abdomino-pelvic CT scan. The primary outcome is the stone-free rate at 3 months. A centralized review of the images will be performed by two specialized radiologists, in a blind and crossed way to allow a homogenization of the results. The secondary outcomes will include the rate of early post-operative urinary tract infection (UTI), the evaluation of post-operative pain, and the safety of the use of furosemide in patients treated by fURS for renal stone laser destruction. As secondary objectives, it is also planned to look at the effect of the prescription of an alpha-blocker as usual treatment on stone-free rate and to assess the agreement between the imaging analysis of the urologist and the specialized radiologist. DISCUSSION: Lithiasis is a public health problem. It affects about 10% of the general population. This prevalence is increasing (multiplied by 3 in 40 years), partly due to changes in the population's eating habits over the years. The lithiasis patient is a patient with a chronic disease requiring annual follow-up and who may suffer from multiple recurrences, with a recurrence rate at 5 years of 50%. Recurrences are partly due to residual fragments left in the kidneys at the end of the operation. Other risk factors for recurrence include dietary hygiene and the presence of an associated metabolic disease. The metabolic blood and urine tests recommended by the Association Française d'Urologie (AFU) can be used to manage these last two problems. As far as residual fragments are concerned, their presence leads to an early recurrence of stones because they form the bed for a new aggregation of crystals in the kidneys. Being able to reduce the rate of residual fragments in patients with the use of furosemide at the end of the intervention therefore seems essential in the management of recurrences in our patients. This will also improve our patients' quality of life. Indeed, lithiasis disease leads to chronic pain associated with acute pain that motivates consultations to the emergency for specialized management. This study is the first to evaluate the impact of forced diuresis with the use of furosemide on the stone-free rate after a fURS for destruction of kidney stone with laser. TRIAL REGISTRATION: ClinicalTrials.gov Identifier: NCT05916963 , first received: 22 June 2023. EU Clinical Trials Register EudraCT Number: 2022-502890-40-00.


Sujet(s)
Furosémide , Calculs rénaux , Études multicentriques comme sujet , Essais contrôlés randomisés comme sujet , Urétéroscopie , Humains , Furosémide/administration et posologie , Furosémide/usage thérapeutique , Calculs rénaux/chirurgie , Calculs rénaux/thérapie , Urétéroscopie/méthodes , Urétéroscopie/effets indésirables , Résultat thérapeutique , Diurétiques/usage thérapeutique , Facteurs temps , Lithotritie par laser/méthodes , Lithotritie par laser/effets indésirables , France , Diurèse/effets des médicaments et des substances chimiques , Urétéroscopes
4.
J Endourol ; 2024 Jul 29.
Article de Anglais | MEDLINE | ID: mdl-39001824

RÉSUMÉ

Introduction: Several complications of retrograde intrarenal surgery have been attributed to inadvertent increases in intrarenal pressure. We recently described the development of an innovative isoprenaline-eluting guidewire (IsoWire). The objective of this study was to investigate the impact of this IsoWire on the intrarenal pressure and evaluate its safety. Materials and Methods: This study was performed in 17 renal units using a porcine model. As controls, the intrarenal pressure, heart rate, and mean arterial pressure were measured for a duration of six minutes with a standard guidewire placed in the renal pelvis. For the experiment, the conventional guidewire was substituted with the IsoWire and the same parameters were measured. Blood samples were taken at one-minute intervals to measure plasma isoprenaline levels. This procedure was repeated on the opposite side. Results: The mean intrarenal pressure reduction was 29% (95% CI: 13%-53%). The mean isoprenaline effect time was 174 seconds. No changes in heart rate (p = .908) or mean arterial pressure (p = .749) were recorded after IsoWire insertion. Plasma isoprenaline levels were below the quantitation threshold. Isoprenaline concentrations in the plasma were below the quantification threshold. Ureteroscopy revealed no ureteral lesions. Conclusions: The IsoWire demonstrated a safe and effective reduction of intrarenal pressure. Additional research is necessary to determine whether ureteral smooth muscle relaxation generated by isoprenaline facilitates easier insertion of a ureteral access sheath, decreases the incidence of ureteral access sheath related ureteral lesions, or even encourage the practice of sheathless retrograde intrarenal surgery.

5.
World J Clin Cases ; 12(21): 4483-4490, 2024 Jul 26.
Article de Anglais | MEDLINE | ID: mdl-39070817

RÉSUMÉ

BACKGROUND: Renal stones ranging 20-40 mm are very common in China. Although no large-sample clinical studies have confirmed the clinical efficacy and safety of this method, there is also a lack of comparative data with traditional treatment. AIM: To investigate the clinical efficacy of flexible ureteroscopy (FURS) and percutaneous nephrolithotomy (PCNL) by postoperative stone clearance and changes in soluble vascular cell adhesion molecule 1 (sVCAM-1) and kidney injury molecule 1 (KIM-1) levels in patients with large kidney stones (> 2 cm in diameter). METHODS: This single-center observational study was performed at a Chinese hospital between January 1, 2021, and October 30, 2023. All 250 enrolled patients were diagnosed with large kidney stones (> 2 cm) and divided into a FURS group (n = 145) and a PCNL group (n = 105) by the surgical method. The FURS group was treated with flexible ureteroscopy and the PCNL group was treated with percutaneous nephrolithotomy. The operation time, time to palinesthesia, intraoperative blood loss, drop in hemoglobin, length of hospital stay, stone clearance rate, and complications were recorded in the two groups. Preoperative and postoperative serum sVCAM-1 levels, erythrocyte sedimentation rate (ESR), urine KIM-1 levels, preoperative and postoperative pain visual analog scale (VAS) and Wisconsin Stone Quality of Life Questionnaire (WISQOL) scores were also documented. RESULTS: All 250 eligible patients completed the follow-up. There were no significant differences in baseline characteristics between the two groups (P > 0.05). The operation time in the FURS group was significantly greater than that in the PCNL group. The time to ambulation, intraoperative blood loss, decrease in hemoglobin, and length of hospital stay were significantly lower in the FURS group than in the PCNL group. The FURS group also had a significantly higher stone clearance rate and a lower incidence of postoperative complications. There was no significant difference in antibiotic use between the groups. Postoperative serum sVCAM-1 levels, urine KIM-1 levels, and VAS scores were lower in the FURS group than in the PCNL group, but postoperative ESR and WISQOL scores were greater in the FURS group than in the PCNL group. CONCLUSION: FURS demonstrated superior clinical efficacy in treating large kidney stones (> 2 cm in diameter) compared PCNL. It not only improved the postoperative stone clearance rate and reduced complications and recovery time but also positively affected serum SCM-1, ESR, and urine KIM-1 levels, subsequent improvement of patient quality of life.

6.
Urolithiasis ; 52(1): 92, 2024 Jun 17.
Article de Anglais | MEDLINE | ID: mdl-38884642

RÉSUMÉ

The purpose of this review is to analyze the trend in optical features and flexibility changes of flexible ureteroscopes over the past decades, and determine the correlation of individual parameters with release period as well as with dimensional parameters. Flexible ureteroscopes mentioned in the literature or those commercially available were searched. To minimize the search bias, the instruments were grouped by release date time-periods of < 2000 year, 2000-2009, 2010-2019, and 2020 onwards. The final review included only those instrument models for which data on minimum and maximum depth of field, field of view, direction of view, and deflection degree had been determined. The correlation among features investigated as well as with release period was also determined. 61 models of flexible ureteroscopes (27 fibreoptic and 34 digital scopes) were included. Among the different features investigated among fiberoptic endoscopes, minimum depth of field positively and negatively correlated with channel size and field of view, respectively, whereas maximum depth of view and field of view positively correlated with overall shaft and deflection degree, respectively. Up and down deflection strongly correlated with each other and both were negatively proportional to the distal tip size. For the digital endoscopes, minimum depth of field negatively and positively correlated with distal tip size and working length, respectively. Maximum depth of field positively correlated with field of view, whereas the latter was negatively proportional to the overall shaft. As for the fiberoptic counterparts, up and down deflection strongly correlated with each other. Field of view, up and down deflection of fiberoptic flexible ureteroscopes, were significantly increased among fiberoptic and digital endoscopes over decades. As flexible ureteroscopy technology has evolved, there has been a trend towards increasing field of view with up and down deflection. Given the importance of scope ergonomics, one aspect of this popularity is the improvement of optical characteristics and deflection degree, which significantly correlates with the release period.


Sujet(s)
Conception d'appareillage , Urétéroscopes , Humains , Technologie des fibres optiques , Rein/imagerie diagnostique , Rein/chirurgie , Urétéroscopie/instrumentation , Urétéroscopie/tendances
8.
J Endourol ; 2024 Jul 01.
Article de Anglais | MEDLINE | ID: mdl-38874939

RÉSUMÉ

Objective: Sepsis is the most serious complication of flexible ureteroscopy (F-URS) and laser lithotripsy. We assessed the influence of positive stone culture (SC) on major infectious complications (sepsis, septic shock). Methods: This prospective study enrolled adult patients deemed suitable for F-URS and laser lithotripsy from nine centers (January 2022-August 2023). Inclusion criteria were as follows: kidney stone(s), preoperative midstream urine culture (MSUC), stone(s) assessed at computed tomography scan, and SC. Exclusion criteria were as follows: bilateral procedures, ureteral stones, and children. Group 1 included patients with sterile SC. Group 2 included patients with positive SC. Data are presented as median (interquartile range). A multivariable logistic regression analysis was performed to evaluate factors associated with having a positive SC. Results: In total, 293 patients were included. Median age was 51.0 (24) years. There were 167 (57.0%) males. Group 2 included 32 (2.5%) patients. Group 2 patients were significantly older [75.0 (14) vs 51.0 (23) years, p = 0.02]. Stone features were similar. Major infectious complications were higher in Group 2 (15.6% vs 0.4%). One patient died because of sepsis in Group 2. Two out of 6 (33.3%) patients with major infectious complications had the same pathogen in MSUC and SC. In the multivariable regression analysis, diabetes (OR 3.23), symptomatic urinary infections within 3 months before operation (OR 4.82) and preoperative stent/nephrostomy (OR 2.92) were factors significantly associated with higher odds of positive SC. Conclusions: Patients with positive SC have a higher incidence of major infectious complications after F-URS lithotripsy. SC should be performed whenever feasible because there is a poor correlation between MSUC and SC.

9.
Urolithiasis ; 52(1): 89, 2024 Jun 14.
Article de Anglais | MEDLINE | ID: mdl-38874782

RÉSUMÉ

To investigate the feasibility of conventional (basketing + dusting) and Moses (pop-dusting) holmium lasers during flexible ureteroscopy (FURS) in the treatment of 2-3 cm renal calculi and to compare the efficiency and safety of the two methods, a total of 230 patients with 2-3 cm kidney stones who underwent FURS were randomly divided into the conventional group and the Moses group. The mode of lithotripsy in the conventional group was fragmentation and dusting. The mode of lithotripsy in the Moses group was dusting and pop-dusting. Clinical and perioperative variables and complications were compared between the two cohorts. Multivariate analyses of factors contributing to the stone-free rate (SFR) and operation time were performed. No statistically significant differences were found in the demographics, renal stone-related data, SFR, or complications between the cohorts. The laser energy was higher in the Moses cohort than in the conventional cohort (119.3 ± 15.2 vs. 92.8 ± 15.1 kJ; P < 0.001), and the operation time was shorter in the Moses cohort than in the conventional cohort (99.5 ± 18.9 vs. 105.3 ± 13.7 min; P = 0.009). When there was isolated stone, the operation time was shorter in the Moses cohort than in the conventional cohort (99.6 ± 17.5 vs. 111.4 ± 10.7 min; P < 0.001), while there was no significant difference between the two cohorts when there were multiple stones (99.5 ± 20 vs. 101.2 ± 14 min; P = 0.415). Multivariate analyses found that an increase in stone volume can decrease the SFR and prolong the operation time, and use of a Moses laser can shorten the operation time. Both holmium laser modes during FURS can effectively treat 2-3 cm renal calculi. The Moses mode is recommended as the first choice for the treatment of isolated 2-3 cm renal stones. When treating multiple stones, the efficiency of these two laser modalities is the same. TRIAL REGISTRATION: ChiCTR2200056091.


Sujet(s)
Calculs rénaux , Lasers à solide , Lithotritie par laser , Durée opératoire , Urétéroscopie , Humains , Urétéroscopie/méthodes , Urétéroscopie/effets indésirables , Urétéroscopie/instrumentation , Calculs rénaux/chirurgie , Lasers à solide/usage thérapeutique , Femelle , Mâle , Adulte d'âge moyen , Lithotritie par laser/méthodes , Lithotritie par laser/instrumentation , Lithotritie par laser/effets indésirables , Adulte , Résultat thérapeutique , Études de faisabilité , Sujet âgé
10.
World J Urol ; 42(1): 294, 2024 May 05.
Article de Anglais | MEDLINE | ID: mdl-38704777

RÉSUMÉ

PURPOSE: To date, no study has evaluated effects of varying brightness settings on image quality from flexible ureteroscopes submerged in saline. The aim was to evaluate blackout and whiteout occurrences in an in-vitro kidney calyx model. MATERIAL AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed enclosed pink in-vitro kidney calyx model submerged in saline. Endoscopic images were captured with ureteroscope tip placed at 5 mm,10 mm and 20 mm distances. The complete range of brightness settings and video capture modes were evaluated for each scope. Distribution of brightness on a grayscale histogram of images was analyzed (scale range 0 to 255). Blackout and whiteout were defined as median histogram ranges from 0 to 35 and 220 to 255, respectively (monitor image too dark or too bright for the human eye, respectively). RESULTS: Blackout occurred with the P7, Pusen 7.5F, 9.2F and WiScope at all distances, and V3 at 20 mm - with lowest brightness settings. Whiteout occurred with Flex-X2s, V3 and P7 at 5 mm and 10 mm, as well as with V3 and P7 at 20 mm - mostly with highest brightness settings. The Flex-Xc had neither blackout nor whiteout at all settings and distances. CONCLUSION: Blackout or whiteout of images is an undesirable property that was found for several scopes, possibly impacting diagnostic and therapeutic purposes during ureteroscopy. These observations form a guide to impact a urologist's choice of instruments and settings.


Sujet(s)
Urétéroscopes , Urétéroscopie , Humains , Conception d'appareillage , Éclairage , Flexibilité , Calices rénaux
11.
Diagnostics (Basel) ; 14(10)2024 May 16.
Article de Anglais | MEDLINE | ID: mdl-38786332

RÉSUMÉ

The ureteral access sheath (UAS) has been a boon and a bane in flexible ureteroscopy (FURS), with its merits and demerits well established. Its design and dimensions were instrumental in reshaping the way flexible scopes were used and were key adjuncts to establishing retrograde intrarenal surgery (RIRS) as a standard of care in the endourological management of renal stones. With the ever-changing landscape of RIRS over the decades shaped by technological advancements in lasers and flexible scopes, the UAS has also continuously evolved. The utility of suction in endourology has recently changed the way RIRS is performed and is a game changer for FURS outcomes. With strong clinical and experimental evidence to support its use, the UAS has undergone a transformative change in the recent past, with its ability to monitor intrarenal pressure and provide a superior vacuum-cleaner effect that improves the trifecta of RIRS, namely an improved single-stage stone-free rate (SFR), minimise complications, and reduce reinterventions. Our comprehensive review outlines the key clinical and experimental evidence and traces the developments that were key to modifying the traditional UAS into a flexible and navigable suction ureteric access sheath (FANS) and highlights how the design and modifications, in turn, influence the ability to push the boundaries of RIRS.

13.
World J Urol ; 42(1): 298, 2024 May 06.
Article de Anglais | MEDLINE | ID: mdl-38709327

RÉSUMÉ

PURPOSE: The aim of the study was to evaluate illumination properties in an in-vitro kidney calyx model in saline. DESIGN AND METHODS: We evaluated a series of contemporary flexible ureteroscopes including the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, as well as OTU WiScope using a 3D-printed closed pink kidney calyx model, submerged in saline. A spectrometer was used for illuminance and color temperature measurements at different openings located at center (direct light), 45° (direct and indirect light) and 90°(indirect light) to the axis of the scope. RESULTS: Maximum illuminance was at the center opening for all scopes (range: 284 to 12,058 lx at 50% brightness and 454 to 11,871 lx at 100% brightness settings). The scope with the highest center illuminance (Flex-Xc) was 26 times superior to the scope with the lowest illuminance (Pusen 7.5Fr) at 100% brightness setting. For each scope, there was a peripheral illuminance drop ranging from - 43 to - 92% at 50% brightness and - 43% to - 88% at 100% brightness settings, respectively (all p < 0.01). Highest drop was for the P7 and the Pusen 9.2F. All scopes had illuminance skew, except the V3. All scopes had a warm color temperature. CONCLUSION: Illumination properties vary between ureteroscopes in an enclosed cavity in saline, and differs at center vs 45° and 90° positions within scopes. Peripheral illuminance drop can be as high as - 92%, which is undesirable. This may affect the choice of ureteroscope and light brightness settings used in surgery by urologists.


Sujet(s)
Conception d'appareillage , Rein , Éclairage , Urétéroscopes , Modèles anatomiques , Humains
14.
J Clin Med ; 13(9)2024 Apr 24.
Article de Anglais | MEDLINE | ID: mdl-38731026

RÉSUMÉ

New suction endoscopes, ureteral access sheaths (UAS) and catheters aim to improve the efficacy of flexible ureteroscopy and optimize its safety. Suction UAS with non-flexible tips have shown promising results, especially in maintaining low intrarenal pressure, but also in removing small debris and reducing the "snow globe" effect. In addition, suctioning UAS with a flexible tip offers the advantage of being able to be navigated through the pyelocaliceal system to where the laser lithotripsy is performed. It can also remove small stone fragments when the flexible ureteroscope is retracted, using the Venturi effect. Direct in-scope suction (DISS) involves aspirating dust and small stone debris through the working channel of a flexible ureteroscope, thus regulating intrarenal pressure and improving visibility. Steerable aspiration catheters are other devices designed to increase stone clearance of the pyelocaliceal system. They are inserted under fluoroscopic guidance into every calyx after retraction of the flexible ureteroscope, alternating irrigation and aspiration to remove dust and small gravels. Combining flexible-tip suction UAS and the DISS technique may offer some advantages worth evaluating. The advantage of using these instruments to achieve a low intrarenal pressure was demonstrated. The true practical impact on the long-term stone-free status is a matter requiring further studies.

15.
Urol Int ; : 1-5, 2024 May 16.
Article de Anglais | MEDLINE | ID: mdl-38754402

RÉSUMÉ

INTRODUCTION: The aim of this study was to evaluate the safety and efficacy of flexible ureteroscopy using a tip-flexible pressure-controlling ureteral access sheath (TFPC-UAS) for renal stones in children. METHODS: Consecutive patients aged 5-18 years with renal stones of diameter 1-3 cm were enrolled between January 2022 and November 2023 at Ganzhou People's Hospital. The patients were treated with flexible ureteroscopy using the TFPC-UAS. The renal pelvic pressure (RPP) parameters were set as follows: control value at -10 mm Hg to 5 mm Hg, warning value at 20 mm Hg, and limit value at 30 mm Hg. The infusion flow rate was set to 100-120 mL/min. A holmium laser (276 µm) was used to fragment the stone at 2.0-2.5 J/pulse with a frequency of 20-30 pulses/s. The cases were analyzed for RPP, operative time, stone-free rate, and complications. RESULTS: A total of 21 consecutive patients were included. Two patients were switched to percutaneous nephrolithotomy owing to sheath placement failure. The RPP was -4.6 ± 2.1 mm Hg. The mean operative time was 56.5 ± 17.1 min. The postoperative hospitalization time was 1.5 ± 0.3 days. The stone-free rates at 1 day and 1 month after surgery were 81.0% and 85.7%, respectively. Residual stones in 2 patients were cleared after extracorporeal shockwave lithotripsy. Three cases of Clavien I complications and one case of Clavien II complications occurred. No major complications (Clavien grade III-V) were observed. CONCLUSIONS: Flexible ureteroscopy with a TFPC-UAS is safe and effective for renal stones in children.

16.
Eur Urol Focus ; 2024 May 23.
Article de Anglais | MEDLINE | ID: mdl-38789313

RÉSUMÉ

BACKGROUND AND OBJECTIVE: The aim of this study was to evaluate the stone-free status (SFS) rate and complications after flexible ureteroscopy (fURS) for treatment of renal stones using a flexible and navigable suction (FANS) ureteral access sheath. METHODS: Data for adults undergoing fURS in 25 centers worldwide were prospectively collected (August 2023 to January 2024). Exclusion criteria were abnormal renal anatomy and ureteral stones. All patients had computed tomography scans before and within 30 d after fURS with a FANS ureteral access sheath. SFS was defined as follows: grade A, zero fragments; grade B, a single fragment ≤2 mm; grade C, a single fragment 2.1-4 mm; and grade D, single/multiple fragments >4 mm. Data for continuous variables are presented as the median and interquartile range (IQR). Multivariable logistic regression was performed to evaluate predictors of grade A SFS. KEY FINDINGS AND LIMITATIONS: The study enrolled 394 patients (59.1% male) with a median age of 49 yr (IQR 36-61). The median stone volume was 1260 mm3 (IQR 706-1800). Thulium fiber laser (TFL) was used in 45.9% of cases and holmium laser in the rest. The median lasing time was 18 min (IQR 11-28) and the median operative time was 49 min (IQR 37-70). One patient required a blood transfusion and 3.3% of patients had low-grade fever. No patient developed sepsis. Low-grade ureteral injury occurred in eight patients (2%). The grade A SFS rate was 57.4% and the grade A + B SFS rate was 97.2%, while 2.8% of patients had grade C or D SFS. Eleven patients underwent repeat fURS. Multivariable analysis revealed that a stone volume of 1501-3000 mm3 (odds ratio 0.50) and of >3000 mm3 (odds ratio 0.29) were significantly associated with lower probability of grade A SFS, while TFL use was associated with higher SFS probability (odds ratio 1.83). Limitations include the lack of a comparative group. CONCLUSIONS AND CLINICAL IMPLICATIONS: fURS using a FANS ureteral access sheath resulted in a high SFS rate with negligible serious adverse event and reintervention rates. PATIENT SUMMARY: We looked at 30-day results for patients undergoing telescopic laser treatment for kidney stones using a special type of vacuum-assisted sheath to remove stone fragments. We found a high stone-free rate with minimal complications.

17.
World J Urol ; 42(1): 355, 2024 May 26.
Article de Anglais | MEDLINE | ID: mdl-38796790

RÉSUMÉ

PURPOSE: Illumination characteristics of flexible ureteroscopes have been evaluated in air, but not in saline, the native operative medium for endourology. The aim was to evaluate light properties of contemporary ureteroscopes in air versus saline, light distribution analysis, and color temperature. METHODS: We evaluated the Storz Flex-Xc and Flex-X2s, Olympus V3 and P7, Pusen 7.5F and 9.2F, and OTU WiScope using a 3D printed black target board in-vitro model submerged in saline. A spectrometer was used for lux and color temperature measurements at different opening locations. RESULTS: Illuminance was higher in saline compared to air (5679 vs. 5205 lx with Flex-Xc, p = 0.02). Illuminance in saline differed between ureteroscopes (ANOVA p < 0.001), with highest for the Flex-Xc at 100% brightness setting (5679 lx), followed by Pusen 9.2F (5280 lx), Flex-X2s (4613 lx), P7 (4371 lx), V3 (2374 lx), WiScope (582 lx) and finally Pusen 7.5F (255 lx). The same ranking was found at 50% brightness setting, with the highest ureteroscope illuminance value 34 times that of the scope with lowest illuminance. Most scopes had maximum illuminance off center, with skewness. Three scopes had two light sources, with one light source for all other scopes. Inter-scope comparisons revealed significant differences of color temperature (ANOVA p < 0.001). CONCLUSION: The study demonstrates the presence of inhomogeneous light spread as well as large differences in illumination properties of ureteroscopes, possibly impacting on the performance of individual scopes in vivo. Additionally, the study suggests that future studies on illumination characteristics of flexible ureteroscopes should ideally be done in saline, and no longer in air.


Sujet(s)
Conception d'appareillage , Éclairage , Urétéroscopes , Urétéroscopie , Lumière , Humains , Solution physiologique salée , Couleur
18.
Arab J Urol ; 22(3): 166-170, 2024.
Article de Anglais | MEDLINE | ID: mdl-38818257

RÉSUMÉ

Purpose: To determine predictors for missing trifecta in patients who underwent flexible ureteroscopy (FURS) for treatment of renal and upper ureteric calculi. Patients and Methods: The data of adult patients with renal or upper ureteral stones who underwent FURS from June 2021 through December 2022 were retrospectively reviewed. Stone-free status (no residual stones > 3 mm) was evaluated after 3 months with non-contrast CT. Modified Clavien classification was used to grade complications. A stone-free status after a single intervention of FURS without complications was defined as trifecta. Patients were divided into two groups (trifecta and non-trifecta). Risk factors for missing trifecta were compared between both groups using univariate and multivariate analyses. Results: Three hundred twenty-three patients with mean age 48.9 ± 13 years and mean stone length 16 ± 5.9 mm were included. The trifecta criteria were applicable for 250 patients (71%). On multivariate analysis, risk factors for missing trifecta were stone multiplicity (OR: 3.326, 95%CI: 1.933-5.725) and non-experienced surgeons (OR: 1.819, 95%CI: 1.027-3.220). Conclusions: Multiple stones and performance of FURS by non-experienced surgeons are the independent risk factors for missing trifecta of FURS.

20.
World J Urol ; 42(1): 233, 2024 Apr 13.
Article de Anglais | MEDLINE | ID: mdl-38613608

RÉSUMÉ

PURPOSE: This study aimed to evaluate the ability of Kidney Stone Calculator (KSC), a flexible ureteroscopy surgical planning software, to predict the lithotripsy duration with both holmium:YAG (Ho:YAG) and thulium fiber laser (TFL). METHODS: A multicenter prospective study was conducted from January 2020 to April 2023. Patients with kidney or ureteral stones confirmed at non-contrast computed tomography and treated by flexible ureteroscopy with laser lithotripsy were enrolled. "Kidney Stone Calculator" provided stone volume and subsequent lithotripsy duration estimation using three-dimensional segmentation of the stone on computed tomography and the graphical user interface for laser settings. The primary endpoint was the quantitative and qualitative comparison between estimated and effective lithotripsy durations. Secondary endpoints included subgroup analysis (Ho:YAG-TFL) of differences between estimated and effective lithotripsy durations and intraoperative outcomes. Multivariate analysis assessed the association between pre- and intraoperative variables and these differences according to laser source. RESULTS: 89 patients were included in this study, 43 and 46 in Ho:YAG and TFL groups, respectively. No significant difference was found between estimated and effective lithotripsy durations (27.37 vs 28.36 min, p = 0.43) with a significant correlation (r = + 0.89, p < 0.001). Among groups, this difference did not differ (p = 0.68 and 0.07, respectively), with a higher correlation between estimated and effective lithotripsy durations for TFL compared to Ho:YAG (r = + 0.95, p < 0.001 vs r = + 0.81, p < 0.001, respectively). At multivariate analysis, the difference was correlated with preoperative (volume > 2000 mm3 (Ho:YAG), 500-750 mm3 SV and calyceal diverticulum (TFL)), operative (fragmentation setting (p > 0.001), and basket utilization (p = 0.05) (Ho:YAG)) variables. CONCLUSION: KSC is a reliable tool for predicting the lithotripsy duration estimation during flexible ureteroscopy for both Ho:YAG and TFL. However, some variables not including laser source may lead to underestimating this estimation.


Sujet(s)
Calculs rénaux , Lithotritie , Calculs urétéraux , Humains , Holmium , Thulium , Urétéroscopie , Études prospectives , Calculs rénaux/chirurgie , Lasers
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE