Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 6.278
Filtrer
1.
Talanta ; 279: 126611, 2024 Jul 24.
Article de Anglais | MEDLINE | ID: mdl-39067202

RÉSUMÉ

Peptidyl arginine deiminase 4 (PAD4) plays a critical role in many autoimmune diseases including rheumatoid arthritis. Herein, a trypsin assisted highly immunoassay method was established to determine PAD4 activity and screen potent inhibitors from herbal plants extracts and purified natural products. The method was applied to determine endogenous PAD4 activity in both cell and tissue lysates, as well as the inhibitory effects of 20 herbal plants and 50 purified natural products. The Cinnamomi ramulus extract showed strongest inhibitory potency with IC50 value lower than 5 µg/mL. Meanwhile, pyrroloquinoline quinone (PQQ), widely used as a dietary supplement, was discovered as a promising PAD4 inhibitor with an IC50 value lower than 4 µM. The inhibition kinetic analysis, drug affinity response target stability (DARTS) and molecular docking were performed to confirm the interaction between PQQ and PAD4. This method has great potential for researchers to monitor activities and discover potential inhibitors of PAD4.

2.
Small Methods ; : e2400738, 2024 Jul 31.
Article de Anglais | MEDLINE | ID: mdl-39082595

RÉSUMÉ

Catalytic nanoparticle@metal-organic framework (MOF) composites have attracted significant interest in point-of-care testing (POCT) owing to their prominent catalytic activity. However, the trade-off between high loading efficiency and high catalytic activity remains challenging because high concentrations of nanoparticles tend to cause the misjoining and collapse of the MOFs. Herein, a facile strategy is reported to encapsulate high concentrations of platinum (Pt) nanoparticles into zeolitic imidazolate framework-8 (ZIF-8) using polydopamine (PDA) as a support for Pt@ZIF-8 and as a flexible scaffold for further immobilization of Pt nanoparticles. The resulting composite (Pt@ZIF-8@PDA@Pt) exhibits ultrahigh Pt nanoparticle loading efficiency, exceptional catalytic activity, stability, and a bright colorimetric signal. Following integration with lateral flow immunoassay (LFIA), the detection limits for pre- and post-catalysis detection of B-type natriuretic peptide (NT-proBNP) are 0.18 and 0.015 ng mL-1, respectively, representing a 6-fold and 70-fold improvement compared to gold nanoparticle-based LFIA. Moreover, Pt@ZIF-8@PDA@Pt-based LFIA achieves 100% diagnostic sensitivity for NT-proBNP in a cohort of 184 clinical samples.

3.
Diagnostics (Basel) ; 14(14)2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-39061657

RÉSUMÉ

BACKGROUND: Recently, the investigation of cerebrospinal fluid (CSF) biomarkers for diagnosing human prion diseases (HPD) has garnered significant attention. Reproducibility and accuracy are paramount in biomarker research, particularly in the measurement of total tau (T-tau) protein, which is a crucial diagnostic marker. Given the global impact of the coronavirus disease pandemic, the frequency of measuring this protein using one of the world's fully automated assays, chemiluminescent enzyme immunoassay (CLEA), has increased. At present, the diagnosis and monitoring of neurological diseases mainly rely on traditional methods, but their accuracy and responsiveness are limited. There is limited knowledge of the accuracy of CLEA in tau measurements. We aimed to measure T-tau protein using CLEA and to elucidate its merits and limitations. METHODS: We randomly selected 60 patients with rapidly progressive dementia, using ELISA and CLEA analysis of cerebrospinal fluid specimens. Additionally, we used Western blotting to detect the presence of 14-3-3 protein and employed real-time quaking-induced conversion (RT-QuIC) assays to analyze the same set of samples. Furthermore, we examined the correlation coefficient between ELISA and CLEA results in a subset of 60 samples. Moreover, using CLEA, we evaluated the diurnal reproducibility, storage stability, dilutability, and freeze-thaw effects in three selected samples. RESULTS: In 172 patients, 172 samples were extracted, with each patient providing only one sample, and a total of 88 (35 men and 53 women) tested positive for HPD in the RT-QuIC assay. In contrast, all CSF samples from the remaining 84 patients without HPD (50 men and 34 women) tested negative in the RT-QuIC assay. Both ELISA and CLEA showed perfect sensitivity and specificity (100%) in measuring T-tau protein levels. In addition, ELISA and CLEA are similar in terms of measurement sensitivity and marginal effect of detection extrema. CLEA analysis exhibited instability for certain samples with T-tau protein levels exceeding 2000 pg/mL, leading to low reproducibility during dilution analysis. CONCLUSIONS: Our findings indicate that CLEA outperforms ELISA in terms of diurnal reproducibility, storage stability, and freeze-thaw effects. However, ELISA demonstrated superior performance in the dilution assay. Therefore, it is imperative to develop innovative approaches for the dilution of biomarker samples for CLEA measurements during clinical trials.

4.
Methods Mol Biol ; 2829: 277-286, 2024.
Article de Anglais | MEDLINE | ID: mdl-38951344

RÉSUMÉ

Quantitative immunoassays, such as the traditional enzyme-linked immunosorbent assay (ELISA), are used to determine concentrations of an antigen in a matrix of unknown antigen concentration. Magnetic immunoassays, such as the Luminex xMAP technology, allow for the simultaneous detection of multiple analytes and offer heightened sensitivity, specificity, low sample volume requirements, and high-throughput capabilities. Here, we describe a quantitative immunoassay using the Luminex MAGPIX® System to determine the antigen concentration from liquid samples with unknown concentrations. In detail, we describe a newly developed assay for determining production yields of Drosophila S2-produced Marburg virus (MARV) glycoprotein in insect-cell-culture-derived supernatant. The potential applications of this assay could extend to the quantification of viral antigens in fluids derived from both in vitro and in vivo models infected with live MARV, thereby providing additional applications for virological research.


Sujet(s)
Antigènes viraux , Microsphères , Animaux , Dosage immunologique/méthodes , Antigènes viraux/immunologie , Antigènes viraux/analyse , Marburgvirus/immunologie , Marburgvirus/isolement et purification , Drosophila , Techniques de culture cellulaire/méthodes , Lignée cellulaire , Test ELISA/méthodes
5.
Ann Lab Med ; 2024 Jul 02.
Article de Anglais | MEDLINE | ID: mdl-38953114

RÉSUMÉ

Background: The accurate measurement of α-fetoprotein (AFP) is critical for clinical diagnosis. However, different AFP immunoassays may yield different results. Appropriate AFP reference materials (RMs) were selected and assigned accurate values for applications with external quality assessment (EQA) programs to standardize AFP measurements. Methods: Forty individual clinical samples and six different concentrations of candidate RMs (Can-RMs, L1-L6) were prepared by the Beijing Center for Clinical Laboratories. The Can-RMs were assigned target values by performing five immunoassays, using WHO International Standard 72/225 as a calibrator, and sent to 45 clinical laboratories in Beijing for AFP measurements. The commutability of all RMs was assessed based on CLSI and the International Federation of Clinical Chemistry and Laboratory Medicine (IFCC) approaches. Analytical performance was assessed for compliance based on accuracy (total error, TE), trueness (bias), and precision (CV). Results: The Can-RMs were commutable for all immunoassays using the CLSI approach and for 6 of 10 assay combinations using the IFCC approach. RMs diluted in WHO RM 72/225 were commutable among all assays with the CLSI approach, except for serum matrix (Autolumo vs. Roche analyzer) and diluted water matrix (Abbott vs. Roche/Mindray analyzer), whereas some inconclusive and non-commutable results were found using the IFCC approach. The average pass rates based on the TE, bias, and CV were 91%, 81%, and 95%, respectively. Conclusions: The commutability of the RMs differed between both evaluation approaches. The Can-RMs exhibited good commutability with the CLSI approach, suggesting their suitability for use with that approach as commutable EQA materials with assigned values and for monitoring the performance of AFP measurements.

6.
J Agric Food Chem ; 72(26): 14967-14974, 2024 Jul 03.
Article de Anglais | MEDLINE | ID: mdl-38957086

RÉSUMÉ

Nanobodies (Nbs) serve as powerful tools in immunoassays. However, their small size and monovalent properties pose challenges for practical application. Multimerization emerges as a significant strategy to address these limitations, enhancing the utilization of nanobodies in immunoassays. Herein, we report the construction of a Salmonella-specific fenobody (Fb) through the fusion of a nanobody to ferritin, resulting in a self-assembled 24-valent nanocage-like structure. The fenobody exhibits a 35-fold increase in avidity compared to the conventional nanobody while retaining good thermostability and specificity. Leveraging this advancement, three ELISA modes were designed using Fb as the capture antibody, along with unmodified Nb422 (FbNb-ELISA), biotinylated Nb422 (FbBio-ELISA), and phage-displayed Nb422 (FbP-ELISA) as the detection antibody, respectively. Notably, the FbNb-ELISA demonstrates a detection limit (LOD) of 3.56 × 104 CFU/mL, which is 16-fold lower than that of FbBio-ELISA and similar to FbP-ELISA. Moreover, a fenobody and nanobody sandwich chemiluminescent enzyme immunoassay (FbNb-CLISA) was developed by replacing the TMB chromogenic substrate with luminal, resulting in a 12-fold reduction in the LOD. Overall, the ferritin-displayed technology represents a promising methodology for enhancing the detection performance of nanobody-based sandwich ELISAs, thereby expanding the applicability of Nbs in food detection and other fields requiring multivalent modification.


Sujet(s)
Test ELISA , Ferritines , Salmonella , Anticorps à domaine unique , Ferritines/immunologie , Ferritines/composition chimique , Ferritines/génétique , Anticorps à domaine unique/composition chimique , Anticorps à domaine unique/génétique , Anticorps à domaine unique/immunologie , Salmonella/immunologie , Salmonella/génétique , Test ELISA/méthodes , Limite de détection , Affinité des anticorps , Anticorps antibactériens/immunologie , Dosage immunologique/méthodes
7.
Bioanalysis ; : 1-13, 2024 Jul 03.
Article de Anglais | MEDLINE | ID: mdl-38957926

RÉSUMÉ

Aim: Endogenous interferents can cause nonselectivity in ligand binding pharmacokinetic assays, leading to inaccurate quantification of drug concentrations. We describe the development of a Gyrolab immunoassay to quantify a new modality, CB307 and discuss strategies implemented to overcome matrix effects and achieve selectivity at the desired sensitivity. Results: Matrix effects were mitigated using strategies including increasing minimum required dilution (MRD) and lower limit of quantification, optimization of antibody orientation, assay buffer and solid phase. Conclusion: The strategies described resulted in a selective method for CB307 in disease state matrix that met bioanalytical method validation (BMV) guidance and is currently used to support clinical pharmacokinetic sample analysis in the first-in-human POTENTIA clinical study (NCT04839991) as a secondary clinical end point.


[Box: see text].

8.
Food Chem ; 459: 140419, 2024 Jul 14.
Article de Anglais | MEDLINE | ID: mdl-39024876

RÉSUMÉ

Fluorescent nanoprobes are widely applied in innovate enzyme-linked immunosorbent assays (ELISA) for detection of fluoroquinolones (FQs) residue in foodstuffs. Nevertheless, the complicated synthesis of nanoprobes hampers their practical applications. Herein, a nanomaterial-independent and fluorescent ELISA for sensitive detection of FQs is developed using the Eu-micelles as signal probe. Non-nanostructured Eu-micelles with high quantum yield and stability are facilely synthesized through the assembly of Eu3+ and ligands. Alkaline phosphatase catalyzes hydrolysis of 4-nitrophenyl phosphate to 4-nitrophenol. The fluorescent Eu-micelles can be readily quenched by 4-nitrophenol via static quenching. The signal generation mechanism integrates well with conventional ELISA systems. The established fluorescent ELISA achieves sensitive detection of FQs with a limit of detection of 0.03 µg/kg. The validation results from LC-MS show that the fluorescent ELISA exhibits good accuracy and recoveries. Our study presents a nanomaterial-independent strategy for developing the rapid immunoassay for FQs, which holds good promise for practical applications.

9.
Vet Parasitol Reg Stud Reports ; 53: 101061, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-39025539

RÉSUMÉ

Canine leishmaniosis (CanL) is caused by the protozoal parasite Leishmania infantum, which is transmitted by sand flies in warm climates across the world. Because dogs are considered a primary domestic reservoir for the parasite that causes leishmaniosis in humans, it is important from a One Health perspective that CanL be properly managed. In endemic regions, CanL is a common differential diagnosis in sick dogs because the clinical signs and clinicopathological disorders of the disease are non-specific, variable, and may overlap those of other common conditions. Diagnosis is based on the presence of compatible clinical signs, laboratory abnormalities, and confirmation by serological and parasitological evidence of infection. Here, we describe the performance of a point-of-care (POC) immunoassay that uses recombinant antigens to detect canine anti- L. infantum antibodies in a convenience sample set from a diagnostic laboratory, a group of canine patients with clinical staging, and in apparently healthy dogs from endemic areas. An immunofluorescence antibody test (IFAT) was used as the semiquantitative reference method. In the convenience sample set with high IFAT titers (≥ 1:800), the POC immunoassay demonstrated perfect agreement with IFAT (100%; 90/90). Using samples from dogs staged as either LeishVet Stage 2 or 3 or LeishVet Stage 1, positive agreement of the POC immunoassay with the IFAT was 98.8% (82/83) and 83.8% (31/37), respectively. The negative agreement with IFAT was 98.9% (272/275) in apparently healthy dogs from endemic areas of Greece and Italy. Since the performance of the POC immunoassay was associated with IFAT titer and clinical stage of CanL, the test may help veterinarians when determining if CanL is likely responsible for a patient's clinical picture or when evaluating an apparently healthy patient prior to vaccination.


Sujet(s)
Anticorps antiprotozoaires , Maladies des chiens , Leishmania infantum , Leishmaniose viscérale , Chiens , Animaux , Maladies des chiens/diagnostic , Maladies des chiens/parasitologie , Maladies des chiens/épidémiologie , Leishmania infantum/immunologie , Leishmania infantum/isolement et purification , Leishmaniose viscérale/médecine vétérinaire , Leishmaniose viscérale/diagnostic , Leishmaniose viscérale/épidémiologie , Leishmaniose viscérale/parasitologie , Anticorps antiprotozoaires/sang , Systèmes automatisés lit malade , Technique d'immunofluorescence/médecine vétérinaire , Sensibilité et spécificité , Mâle , Femelle , Maladies endémiques/médecine vétérinaire
10.
J Clin Microbiol ; : e0062924, 2024 Jul 19.
Article de Anglais | MEDLINE | ID: mdl-39028178

RÉSUMÉ

The PATHFAST TB LAM Ag assay is based on a chemiluminescent enzyme immunoassay to quantify lipoarabinomannan (LAM) in sputum within 1 h, and was developed as an alternative to conventional culture methods for monitoring tuberculosis (TB) treatment. This study aimed to evaluate the analytical performance and initial clinical feasibility of using five Mycobacterium tuberculosis variants, 178 non-tuberculous mycobacteria (NTM), 34 upper respiratory and oral cavity microorganisms, 100 sputum specimens from untreated patients, and potential interfering substances, including 27 drugs. The results reveled a single-site repeatability coefficient of variation (CV) of 5.2%-7.0%, and a multi-site reproducibility CV of 7.1%-8.4%. The limit of blank, limit of detection, and limit of quantification were 3.03 pg/mL, 6.67 pg/mL, and 7.44 pg/mL, respectively. Linearity was observed over the analytical measurement range (10.0 pg/mL-50,000 pg/mL), and no hook effect was observed. The assay tended to cross-react with slow-growing NTMs, but not with common upper respiratory and oral cavity microorganisms, except Nocardia asteroides, Nocardia farcinica, and Tsukamurella paurometabola. No interference was observed in the presence of mucin, blood, or major anti-TB, anti-HIV, and anti-pneumonia drugs. Regarding clinical performance, the assay had a sensitivity of 88.8% (95% CI: 80.0%-94.0%) and specificity of 100.0% (95% CI: 83.9%-100.0%) using mycobacterial culture as the reference standard, and a correlation (Spearman's r = -0.770) was observed between LAM concentration and time to detection of culture. These findings show, for the first time, that the PATHFAST TB LAM Ag assay has potential value for monitoring TB treatment.

11.
Curr Res Immunol ; 5: 100080, 2024.
Article de Anglais | MEDLINE | ID: mdl-39026560

RÉSUMÉ

Cytokines regulate periodontal pathogenesis and are relevant estimates of current disease activity. There is sparse information on status of cytokine protein levels in periodontal pocket (gingival) tissues. The current study analysed proteins and transcripts of selected cytokines in varying severity of periodontal disease and elucidated cytokine/cytokine ratios that best indicated periodontal disease severity, in gingival tissues. A total of 92 participants comprising of generalised moderate periodontitis (GMP, n = 18), generalised severe periodontitis (GSP, n = 46) and periodontally healthy controls (PHC, n = 25) were recruited for the study. Interproximal gingival tissue samples were utilised for cytokine protein estimation and mRNA quantification by qRT-PCR and ELISA respectively. Selected key pro and anti-inflammatory cytokines, also representative of various Th subsets were analysed. ROC curve analysis was performed and Youden index was calculated for individual cytokines and pro/anti-inflammatory cytokine ratio to estimate the best indicator of periodontal severity/progression in tissues. IL-1ß, TGF-ß and IFN-γ cytokine protein levels varied significantly (p ≤ 0.05) with severity of periodontal disease between groups. On comparison between deep and shallow sites within same participant, deep sites showed significant elevation of TGF-ß (p ≤ 0.01) and IFN-γ (p ≤ 0.05) and IL-17 cytokines and shallow sites showed elevation of IL-4(p ≤ 0.01) and IL-1ß (p ≤ 0.05) cytokines. Analysis of transcripts showed IFN-γ and IL-1ß transcript predominance in GSP (p = 0.01) compared to PHC. ROC analysis illustrated 97% sensitivity, 93% specificity with Youden index of 90% for IL-1ß cytokine and 81%sensitivity, 79% specificity with a Youden index of 60% for IL-1ß/TGF-ß ratio In periodontal pocket tissue, a lack of distinct predominance of specific cytokines between study groups or between shallow and deep sites affected by periodontal disease was observed. However, ROC analysis of cytokines revealed IL-1ß cytokine and IL-1ß/TGF-ß ratio as promising indicators of periodontal disease severity in gingival tissues.

12.
Forensic Sci Int ; 361: 112153, 2024 Jul 16.
Article de Anglais | MEDLINE | ID: mdl-39029141

RÉSUMÉ

This study aimed to identify if biological material could be detected on the opposite side to deposition on fabric by commonly used presumptive and/or secondary tests. Additionally, this study aimed to ascertain if there is a difference in the DNA quantity and quality from samples obtained from both sides of the same substrate: cotton, polyester, denim, or combined viscose and polyester swatches. Blood, semen, or saliva (25 µL) was deposited on one side of 5 replicates of each fabric type and left for 24 h. Blood swatches were tested using Hemastix® and the ABACard® HemaTrace® immunoassay, semen swatches were tested using acid phosphatase (AP) reagent, the ABACard® p30® immunoassay and hematoxylin and eosin staining, and saliva swatches were tested using Phadebas® paper and the RSID-Saliva™ immunoassay. Both sides of each swatch were separately wet/dry swabbed and subjected to DNA analysis. Blood was able to be detected on the underside of all fabrics using both tests. Semen was able to be detected on the underside of swatches using the presumptive AP test but not p30®, and sperm was rarely observed. Saliva was able to be detected by RSID-Saliva™ but not Phadebas® paper when the underside of swatches were tested. Across all biological materials, DNA was able to be recovered from the top side of all 60 swatches. For the underside, DNA was able to be recovered from 54 swatches. Of the 6 swatches that DNA was unable to be recovered from, one sample was from semen and the rest were from saliva. This study has demonstrated that DNA and components of interest in forensically relevant biological material can be recovered from the opposite side to where it was originally deposited, and that observing biological material and/or DNA on one side of fabric does not definitively indicate direct deposition on that side.

13.
Talanta ; 279: 126576, 2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-39018952

RÉSUMÉ

Herein, we developed a platinum-copper nano-enzyme-linked immunosorbent assay (NLISA) based split diagnostic platform for the ultrasensitive detection of cardiac troponin I (cTnI). The PtCu nanozyme synthesized by one-pot synthesis exhibited ultra-high peroxidase-like activity (35.17 U mg-1), which was about 4.5 times higher than that of the unmodified Pt nanozyme (8.83 U mg-1). Due to the efficient peroxidase-like activity of the copper-platinum complexed nanozyme, transduction and sequential amplification of cTnI biological signals were achieved in combination with a liposome-embedded amplification strategy. The encapsulation efficiency was calculated by introducing a liposomal bilayer model, which showed that the introduction of a single liposomal molecule could amplify the signal up to 870-fold, thus promising a high sensitivity test. Notably, the dynamic response of cTnI was in the range of 0.1-5000 pg mL-1 with an ultra-low detection limit (0.048 pg mL-1). The developed NLISA analysis system provides a new way to discover efficient and sensitive alternatives to ELISA kits, which can meet the practical needs of community healthcare testing conditions and rapid testing in hospitals.

14.
J Pharm Biomed Anal ; 249: 116364, 2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-39047461

RÉSUMÉ

In preclinical protein therapeutic development studies, the emergence of anti-drug antibodies (ADA) can potentially impact drug pharmacokinetics and safety. While immunogenicity assessment is not mandatory in preclinical studies, banking samples can be valuable for interpreting unexpected pharmacological responses. Immunoassays that use generic reagents across different drug molecules can simplify ADA assessment and expedite sample evaluations. This work showcases the ability of the Gyrolab automated immunoassay platform to detect and quantify both drug-free and drug-bound (total) ADAs to monoclonal antibody (mAb) therapeutics in cynomolgus monkey preclinical studies. Compared to the previously reported total ADA ELISA, the Gyrolab assay exhibited a wider signal dynamic range and increased drug tolerance. Similar sensitivity, dynamic range and cut point factors were observed for four therapeutic mAbs of different isotypes using the Gyrolab assay. Here we present a comparison of ADA assays using bridging ELISA, total ADA ELISA and total ADA Gyrolab formats in a cynomolgus monkey study where the subjects were treated with a single dose of a mAb therapeutic. We demonstrate that the total ADA assays detected host ADA responses at earlier time points compared to the bridging ELISA. The Gyrolab assay has the best correlation between signal-to-noise (S/N) and titer over a wide ADA concentration range, highlighting the utility of Gyrolab in S/N reporting of ADA response to eliminate the need for secondary titer assays. Collectively, our results demonstrate that the generic ADA Gyrolab assay minimizes the necessity for extensive assay development and optimization for therapeutic mAbs, streamlining preclinical immunogenicity assessment to enable interpretation of pharmacological data.

15.
J Prev Alzheimers Dis ; 11(4): 823-830, 2024.
Article de Anglais | MEDLINE | ID: mdl-39044490

RÉSUMÉ

BACKGROUND: Blood-based AD biomarkers such as plasma P-tau217 are increasingly used in clinical trials as a screening tool. OBJECTIVES: To assess the utility of an electrochemiluminescence (ECL) immunoassay in predicting brain amyloid PET status in cognitively unimpaired individuals. SETTING: Plasma samples collected at baseline, week 12, and week 240 or endpoint originated from the Anti-Amyloid Treatment in Asymptomatic Alzheimer's Disease (A4) trial and the companion Longitudinal Evaluation of Amyloid Risk and Neurodegeneration (LEARN) study. PARTICIPANTS: Both A4 and LEARN enrolled eligible cognitively unimpaired persons 65 to 85 years. Individuals with elevated brain amyloid PET levels were eligible for the A4 Study, while those without elevated brain amyloid PET levels were eligible for the LEARN Study. INTERVENTION: Participants in the A4 Study received intravenous solanezumab (up to 1600 mg) or placebo every 4 weeks. The LEARN Study is an observational study without intervention. MEASUREMENTS: Plasma P-tau217 concentration levels from A4 Study participants were measured using an ECL immunoassay. Receiver Operating Characteristic (ROC) curve analysis was performed for each biomarker against amyloid positivity, defined by ≥22 CL and ≥ 33 CL. RESULTS: Receiver operating characteristic curve (ROC) analysis indicates high diagnostic value of P-tau217 in individuals with amyloid PET ≥ 20 (Area under the ROC (AUROC): 0.87) and ≥ 33 CL (AUROC: 0.89). Repeated testing with the placebo group taken 12 weeks apart (range: 68 to 143 days) and the LEARN participants taken between 1.4 and 1.75 years resulted in a strong positive correlation (Corr. 0.91 (0.90 to 0.92)). CONCLUSION: An ECL immunoassay testing plasma P-tau217 accurately predicts amyloid PET positivity in cognitively unimpaired individuals. Our future analyses aim to determine if use of this assay may reduce the screening burden of preclinical individuals into anti-amyloid clinical trials.


Sujet(s)
Maladie d'Alzheimer , Marqueurs biologiques , Tomographie par émission de positons , Protéines tau , Humains , Maladie d'Alzheimer/imagerie diagnostique , Maladie d'Alzheimer/sang , Maladie d'Alzheimer/diagnostic , Sujet âgé , Protéines tau/sang , Mâle , Femelle , Marqueurs biologiques/sang , Sujet âgé de 80 ans ou plus , Études longitudinales , Anticorps monoclonaux humanisés/usage thérapeutique , Encéphale/imagerie diagnostique , Encéphale/métabolisme , Peptides bêta-amyloïdes/sang , Peptides bêta-amyloïdes/métabolisme
16.
J Hazard Mater ; 477: 135296, 2024 Jul 22.
Article de Anglais | MEDLINE | ID: mdl-39059293

RÉSUMÉ

A lateral flow immunoassay strip (LFIAS) is one of the most frequently rapid test technologies for carbofuran (CAR). Nevertheless, the LFIAS has a poor quantitative capability and low sensitivity. And, it also requires often complex sample handling steps, making testing time longer. In this study, Fe3O4 nanoparticles were successively modified with MIL-100(Fe)-based metal-organic framework (MOF) and chloroplatinic acid hexahydrate to obtain a core-shell complex of Fe3O4-MOF-Pt. The complex had a peroxidase-mimicking activity catalytic function that enabled signal amplification and sensitivity enhancement. Upon coupling with carbofuran monoclonal antibody (CAR-mAb), the magnetic separation properties of the probe enabled target-specific enrichment. The LFIAS based on Fe3O4-MOF-Pt nanocomposites could detect CAR in the range of 0.25-50 ng mL-1 with a limit of detection (LOD) of 0.15 ng mL-1, enabling colorimetric and catalytic analysis. In addition, the method showed high specificity and stability for detecting CAR in various vegetables, and recovery rates of the spiked samples were 91.40%-102.40%. In conclusion, this study provided one-stop detection of "target enrichment-visual inspection". While lowering the LOD, it reduced the detection time and improved the detection efficiency. The multifunctional Fe3O4-MOF-Pt nanocomposite provides an idea for the construction of novel multifunctional probes to improve the detection performance of conventional LFIAS.

17.
Biosensors (Basel) ; 14(7)2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-39056618

RÉSUMÉ

Misusage of tetracycline (TC) antibiotics residue in animal food has posed a significant threat to human health. Therefore, there is an urgent need to develop highly sensitive and robust assays for detecting TC. In the current study, gold and platinum nanoparticles were deposited on carbon nanotubes (CNTs) through the superposition method (Au@Pt/CNTs-s) and one-pot method (Au@Pt/CNTs-o). Au@Pt/CNTs-s displayed higher enzyme-like activity than Au@Pt/CNTs-o, which were utilized for the development of sensitive magnetic immunoassays. Under the optimized conditions, the limits of detection (LODs) of magnetic immunoassays assisted by Au@Pt/CNTs-s and Au@Pt/CNTs-o against TCs could reach 0.74 ng/mL and 1.74 ng/m, respectively, which were improved 6-fold and 2.5-fold in comparison with conventional magnetic immunoassay. In addition, the measurement of TC-family antibiotics was implemented by this assay, and ascribed to the antibody used that could recognize TC, oxytetracycline, chlortetracycline, and doxycycline with high cross-reactivity. Furthermore, the method showed good accuracy (recoveries, 92.1-114.5% for milk; 88.6-92.4% for pork samples), which also were applied for determination of the targets in real samples. This study provides novel insights into the rapid detection of targets based on high-performance nanocatalysts.


Sujet(s)
Antibactériens , Or , Nanoparticules métalliques , Nanotubes de carbone , Platine , Tétracycline , Nanotubes de carbone/composition chimique , Dosage immunologique/méthodes , Or/composition chimique , Platine/composition chimique , Antibactériens/analyse , Nanoparticules métalliques/composition chimique , Tétracycline/analyse , Animaux , Limite de détection , Techniques de biocapteur , Lait/composition chimique
18.
Biosensors (Basel) ; 14(7)2024 Jul 08.
Article de Anglais | MEDLINE | ID: mdl-39056608

RÉSUMÉ

The demand for accurate and efficient immunoassays calls for the development of precise, high-throughput analysis methods. This paper introduces a novel approach utilizing a weak measurement interface sensor for immunoassays, offering a solution for high throughput analysis. Weak measurement is a precise quantum measurement method that amplifies the weak value of a system in the weak interaction through appropriate pre- and post-selection states. To facilitate the simultaneous analysis of multiple samples, we have developed a chip with six flow channels capable of conducting six immunoassays concurrently. We can perform real-time immunoassay to determine the binding characteristics of spike protein and antibody through real-time analysis of the flow channel images and calculating the relative intensity. The proposed method boasts a simple structure, eliminating the need for intricate nano processes. The spike protein concentration and relative intensity curve were fitted using the Log-Log fitting regression equation, and R2 was 0.91. Utilizing a pre-transformation approach to account for slight variations in detection sensitivity across different flow channels, the present method achieves an impressive limit of detection(LOD) of 0.85 ng/mL for the SARS-CoV-2 the severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) spike protein, with a system standard deviation of 5.61. Furthermore, this method has been successfully verified for monitoring molecular-specific binding processes and differentiating binding capacities.


Sujet(s)
Techniques de biocapteur , COVID-19 , SARS-CoV-2 , Glycoprotéine de spicule des coronavirus , Glycoprotéine de spicule des coronavirus/analyse , Dosage immunologique/méthodes , Humains , COVID-19/diagnostic , COVID-19/virologie , Limite de détection , Tests de criblage à haut débit
19.
Biosensors (Basel) ; 14(7)2024 Jul 21.
Article de Anglais | MEDLINE | ID: mdl-39056631

RÉSUMÉ

Mycotoxins are secondary products produced primarily by fungi and are pathogens of animals and cereals, not only affecting agriculture and the food industry but also causing great economic losses. The development of rapid and sensitive methods for the detection of mycotoxins in food is of great significance for livelihood issues. This study employed an amino-functionalized zirconium luminescent metal-organic framework (LOF) (i.e., UiO-66-NH2). Click chemistry was utilized to assemble UiO-66-NH2 in a controlled manner, generating LOF assemblies to serve as probes for fluorescence-linked immunoassays. The proposed fluoroimmunoassay method for Zearalenone (ZEN) and Fumonisin B1 (FB1) detection based on the UiO-66-NH2 assembled probe (CLICK-FLISA) afforded a linear response range of 1-20 µmol/L for ZEN, 20 µmol/L for FB1, and a very low detection limit (0.048-0.065 µmol/L for ZEN; 0.048-0.065 µmol/L for FB1). These satisfying results demonstrate promising applications for on-site quick testing in practical sample analysis. Moreover, the amino functionalization may also serve as a modification strategy to design luminescent sensors for other food contaminants.


Sujet(s)
Fumonisines , Réseaux organométalliques , Zea mays , Zéaralénone , Fumonisines/analyse , Zéaralénone/analyse , Réseaux organométalliques/composition chimique , Zea mays/composition chimique , Chimie click , Dosage fluoroimmunologique/méthodes , Techniques de biocapteur , Contamination des aliments/analyse , Limite de détection , Mycotoxines/analyse
20.
Toxins (Basel) ; 16(7)2024 Jul 22.
Article de Anglais | MEDLINE | ID: mdl-39057965

RÉSUMÉ

Shiga toxin-producing Escherichia coli (STEC) causes a wide spectrum of diseases including hemorrhagic colitis and hemolytic uremic syndrome (HUS). Previously, we developed a rapid, sensitive, and potentially portable assay that identified STEC by detecting Shiga toxin (Stx) using a B-cell based biosensor platform. We applied this assay to detect Stx2 present in food samples that have been implicated in previous STEC foodborne outbreaks (milk, lettuce, and beef). The STEC enrichment medium, modified Tryptone Soy Broth (mTSB), inhibited the biosensor assay, but dilution with the assay buffer relieved this effect. Results with Stx2a toxoid-spiked food samples indicated an estimated limit of detection (LOD) of ≈4 ng/mL. When this assay was applied to food samples inoculated with STEC, it was able to detect 0.4 CFU/g or 0.4 CFU/mL of STEC at 16 h post incubation (hpi) in an enrichment medium containing mitomycin C. Importantly, this assay was even able to detect STEC strains that were high expressors of Stx2 at 8 hpi. These results indicate that the STEC CANARY biosensor assay is a rapid and sensitive assay applicable for detection of STEC contamination in food with minimal sample processing that can complement the current Food Safety Inspection Service (US) methodologies for STEC.


Sujet(s)
Techniques de biocapteur , Microbiologie alimentaire , Lactuca , Escherichia coli producteur de Shiga-toxine , Escherichia coli producteur de Shiga-toxine/isolement et purification , Techniques de biocapteur/méthodes , Lactuca/microbiologie , Contamination des aliments/analyse , Lait/microbiologie , Animaux , Shiga-toxine-2/analyse , Shiga-toxine-2/génétique , Limite de détection , Viande rouge/microbiologie , Bovins
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE