Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 1 de 1
Filtrer
Plus de filtres











Base de données
Gamme d'année
1.
Clin Transl Oncol ; 26(2): 424-433, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-37395988

RÉSUMÉ

INTRODUCTION: To guarantee treatment reproducibility and stability, immobilization devices are essential. Additionally, surface-guided radiation therapy (SGRT) serves as an accurate complement to frameless stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) by aiding patient positioning and real-time monitoring, especially when non-coplanar fields are in use. At our institute, we have developed a surface-guided SRS (SG-SRS) workflow that incorporates our innovative open-face mask (OM) and mouth bite (MB) to guarantee a precise and accurate dose delivery. METHODS: This study included 40 patients, and all patients were divided into closed mask (CM) and open-face mask (OM) groups according to different positioning flow. Cone beam computed tomography (CBCT) scans were performed, and the registration results were recorded before and after the treatment. Then Bland-Altman method was used to analyze the consistency of AlignRT-guided positioning errors and CBCT scanning results in the OM group. The error changes between 31 fractions in one patient were recorded to evaluate the feasibility of monitoring during treatment. RESULTS: The median of translation error between stages of the AlignRT positioning process was (0.03-0.07) cm, and the median of rotation error was (0.20-0.40)°, which were significantly better than those of the Fraxion positioning process (0.09-0.11) cm and (0.60-0.75)°. The mean bias values between the AlignRT guided positioning errors and CBCT were 0.01 cm, - 0.07 cm, 0.03 cm, - 0.30°, - 0.08° and 0.00°. The 31 inter-fractional errors of a single patient monitored by SGRT were within 0.10 cm and 0.50°. CONCLUSIONS: The application of the SGRT with an innovative open-face mask and mouth bite device could achieve precision positioning accuracy and stability, and the accuracy of the AlignRT system exhibits excellent constancy with the CBCT gold standard. The non-coplanar radiation field monitoring can provide reliable support for motion management in fractional treatment.


Sujet(s)
Tumeurs du cerveau , Radiochirurgie , Radiothérapie guidée par l'image , Humains , Radiochirurgie/méthodes , Positionnement du patient , Tumeurs du cerveau/imagerie diagnostique , Tumeurs du cerveau/radiothérapie , Tumeurs du cerveau/chirurgie , Reproductibilité des résultats , Masques , Radiothérapie guidée par l'image/méthodes , Encéphale , Tomodensitométrie à faisceau conique/méthodes , Planification de radiothérapie assistée par ordinateur/méthodes
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE