Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 19 de 19
Filtrer
1.
J Biophotonics ; 17(8): e202400139, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38934100

RÉSUMÉ

The combination of polydioxanone (PDO) threads with other technologies has garnered significant interest for rejuvenation purposes. Photobiomodulation (PBM) has the potential to improve patient comfort and recovery after minimally invasive rejuvenation protocols and also contribute to the overall efficacy of these procedures, fostering an integrative approach to cutaneous rejuvenation. The objective os this work was to investigate concurrent application of PDO threads and red LED PBM on glabellar static wrinkles, in a parallel randomized sham-controlled trial. Forty individuals with Glogau aging classification levels 3 and 4, static glabellar wrinkles, and no significant comorbidities received PDO threads applied along glabellar line. Effective PBM group received 1.35 J and 630 nm red LED light punctually along threads, twice weekly for nine sessions over 30 days. The outcome measures were swelling assessment, dermal thickness and PDO thread degradation via linear ultrasound. No swelling was detected 24 h post-PDO thread application, hindering PBM effect assessment. PDO threads induced dermal thickening; no added effect with PBM. No significant difference in thread hydrolysis between groups, though some ultrasound records inconclusive on thread presence. The absence of swelling may stem from various factors, including the timing of post-procedure swelling assessment, operator proficiency in thread application, and procedural characteristics. No evidence supports the notion that PBM augments dermal thickening, however other light parameters should be studied. Insufficient data to demonstrate PBM's effectiveness in controlling post-procedure swelling. Combination of PBM with PDO thread application doesn't enhance dermal thickening, nor accelerate thread degradation at the parameters used here.


Sujet(s)
Photothérapie de faible intensité , Polydioxanone , Vieillissement de la peau , Humains , Polydioxanone/composition chimique , Vieillissement de la peau/effets des radiations , Femelle , Adulte d'âge moyen , Méthode en double aveugle , Mâle , Adulte , Sujet âgé , Rajeunissement
2.
Skin Res Technol ; 30(4): e13681, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38584576

RÉSUMÉ

OBJECTIVE: Safe, effective, and biocompatible minimally invasive procedures with the potential to stimulate collagen production have been made to recover dermal thickness and skin quality. The main of this animal model experiment was to observe the effect of poly-L-lactic acid (PLLA) and polydioxanone (PDO) biostimulators in collagen I and III after hypodermal injection. METHODOLOGY: Sixteen adult female rats (Wistar) were randomized into four groups and had dorsal treatment with: G1: hypodermic subcision (HS) only; G2: HS and PLLA hypodermic injection (HI), G3: HS and PDO HI; G4: Control, with no treatment. RESULTS: In histochemical, it was observed hypodermal and dermal tissue in more organized thickness in G3 and in G4 when compared to G1 and G2. There was few difference in G1 compared to G4. The tissue of G2 showed irregularities in the arrangement of collagen fibers, less defined structure and lower distribution of type I collagen compared to the other groups. There is a greater tendency for the proportions of type III collagen among tissues treated with both biostimulators (G2 and G3). PLLA and PDO had relatively similar percentages of collagen when compared to G4. The amount of type I collagen was higher in tissues treated with subcision, while type III collagen was higher in tissues treated with both biostimulators. CONCLUSION: G3 showed better performance in collagen production, although small, when compared with G2.


Sujet(s)
Collagène de type I , Polydioxanone , Polyesters , Rats , Femelle , Animaux , Polydioxanone/pharmacologie , Collagène de type III , Rat Wistar , Collagène
3.
Tissue Eng Part C Methods ; 30(3): 102-112, 2024 Mar.
Article de Anglais | MEDLINE | ID: mdl-38271574

RÉSUMÉ

The aim of this study was to assess the bone regeneration potential of a polydioxanone (PDO) scaffold together with recombinant human bone morphogenetic protein-2 (rhBMP-2) for the reconstruction of large bone defect. In total, 24 male rats (6 months old) were subjected to bilateral femoral stabilization using titanium plates to create a 2 mm gap, and reconstruction using rhBMP-2 (Infuse®; 3.25 µg). The bone defects were covered with PDO (PDO group), or with titanium mesh (Ti group). Animals were euthanized on days 14 and 60. Simultaneously, 16 rats received PDO and Ti in their dorsum for the purpose of biocompatibility analysis at 3, 5, 7, and 10 days postoperatively. X-ray densitometry showed a higher density in the PDO group on day 14. On day 60, coverage of the bone defect with PDO showed a larger quantity of newly formed bone than that found for the Ti group, a lower inflammatory infiltrate value, and a more significant number of blood vessels on day 14. By immunohistochemical assessment, runt-related transcription factor 2 (RUNX2) and osteocalcin (OCN) showed higher labeling on day 14 in the PDO group. On day 60, bone morphogenetic protein-2 (BMP-2) showed higher labeling in the PDO group, whereas Ti showed higher labeling for osteoprotegerin, nuclear factor kappa B ligand-activating receptor, RUNX2, and OCN. Furthermore, biocompatibility analysis showed a higher inflammatory response in the Ti group. The PDO scaffold enhanced bone regeneration when associated with rhBMP-2 in rat femur reconstruction. Impact statement Regeneration of segmental bone defects is a difficult task, and several techniques and materials have been used. Recent advances in the production of synthetic polymers, such as polydioxanone (PDO), produced by three-dimensional printing, have shown distinct characteristics that could improve tissue regeneration even in an important bone defect. The present preclinical study showed that PDO membranes used as scaffolds to carry recombinant human bone morphogenetic protein-2 (rhBMP-2) improved bone tissue regeneration by more than 8-fold when compared with titanium mesh, suggesting that PDO membranes could be a feasible and useful material for use in guided bone regeneration. (In English, viable is only used for living creatures capable of sustaining life.


Sujet(s)
Sous-unité alpha 1 du facteur CBF , Polydioxanone , Mâle , Rats , Humains , Animaux , Nourrisson , Polydioxanone/pharmacologie , Titane , Protéine morphogénétique osseuse de type 2/pharmacologie , Facteur de croissance transformant bêta/pharmacologie , Régénération osseuse , Protéines recombinantes/pharmacologie , Fémur/imagerie diagnostique
4.
Membranes (Basel) ; 13(12)2023 Dec 14.
Article de Anglais | MEDLINE | ID: mdl-38132911

RÉSUMÉ

Dehiscence in surgeries involving membranes often leads to bacterial contamination, hindering the healing process. This study assessed bacterial colonization on various membrane materials. Polydioxanone (PDO) membranes, with thicknesses of 0.5 mm and 1 mm, and a collagen membrane were examined. Packages containing polystyrene pins were crafted using these membranes, attached to 24-well plates, and exposed to oral bacteria from supra and subgingival biofilm. After a week's anaerobic incubation, biofilm formation was evaluated using the DNA-DNA hybridization test. Statistical analysis employed the Kruskal-Wallis test with Dunn's post hoc test. The biofilm on the polystyrene pins covered by the 0.5 mm PDO membrane showed a higher count of certain pathogens. The collagen membrane had a greater total biofilm count on its inner surface compared to both PDO membranes. The external collagen membrane face had a higher total biofilm count than the 0.5 mm PDO membrane. Furthermore, the 1 mm PDO membrane exhibited a greater count of specific pathogens than its 0.5 mm counterpart. In conclusion, the collagen membrane presented more biofilm and pathogens both internally and on its inner surface.

5.
Rev. Ciênc. Saúde ; 13(4): 46-51, Dezembro 2023.
Article de Anglais, Portugais | LILACS | ID: biblio-1526801

RÉSUMÉ

Este estudo relata um caso de flacidez abdominal após 3 gestações no qual foi utilizada a técnica de fios de polidioxanona (PDO) lisos e espiculados, técnica ainda não descrita na literatura paratratarestaqueixa.Apacientefoiacompanhadapor90dias,ehouvemelhoradaabertura da prega umbilical, do tônus da pele, de densidade dérmica e da flacidez tissular após 60 dias. Neste período, a paciente declarou estar totalmente satisfeita e foiestabelecidaaaltadotratamento.Comestepresenterelatodecasopodemosconcluirquea terapia combinada de fios de PDO parafusos e fios de PDO espiculados (Sculpt®) apresentam resultados muito expressivos em relação a qualidade da pele promovendo melhora visível na flacidez tissular


Thisstudyreportsacaseofabdominalflaccidityafterthreepregnancies,inwhichthetechnique ofsmoothandspiculatedpolydioxanonethreadswasused,atechniquenotyetdescribedinthe literature to treat this complaint. The patient was followed up for 90 days, but there was an improvement in the opening of the umbilical fold, skin tone, increase in dermal density and especially a reduction in tissue flaccidity in 60 days. During this period, the patient declared thatshewascompletelysatisfied,anddischargefromtreatmentwasestablished.Withthiscase report, we can conclude that the combined therapy of PDO threads screws and PDO threads spiculated (Sculpt®) presentvery expressive results about the quality of the skin, promoting a visible improvement in tissue flaccidity


Sujet(s)
Humains , Présentations de cas , Abdomen , Hypotonie musculaire
6.
Polymers (Basel) ; 15(4)2023 Feb 09.
Article de Anglais | MEDLINE | ID: mdl-36850154

RÉSUMÉ

Guided bone regeneration (GBR) is an approach that induces osteopromotion through the regenerative membranes. These barriers exhibit bioactive behavior and mechanical function. Polydioxanone is a synthetic option, already used in medicine and dentistry, with good results in bone regeneration. This study aimed to evaluate bone repair in critical defects in rat calvaria using a polydioxanone membrane (Plenum® Guide) compared with a commercially available collagen-based membrane (Bio-Gide®). The bone defects were filled with Plenum® Osshp, a synthetic bone graft, hydroxyapatite:ß-tricalcium phosphate, 70:30%, Group PG (Plenum® Guide + Plenum® Osshp), and Group BG (Geistlich Bio-Gide® + Plenum® Osshp). The specimens were submitted to immunohistochemical (RUNX2 and OPN), gene expression (RUNX2, IBSP, and VEGF), histometric, and microtomography analyses after 07, 15, 30, and 60 days postoperative. PG group showed greater immunolabeling area for RUNX2 and OPN, higher gene expression of VEGF (3.15 ± 0.85), and IBSP (24.9 ± 0.59). However, there was no statistical difference between groups in the histometric analysis regarding the percentage of connective tissue PG (0.83 ± 0.45), BG (0.70 ± 0.34), neoformed bone PG (0.60 ± 0.4), BG (0.65 ± 0.51), and remaining biomaterial PG (0.84 ± 0.31), BG (0.91 ± 0.33). In addition, there was no statistical difference between groups by micro-CT analysis. The absorbable-synthetic membrane, Plenum® Guide, is an effective membrane for guided bone regeneration.

7.
J Cutan Aesthet Surg ; 16(4): 325-334, 2023.
Article de Anglais | MEDLINE | ID: mdl-38314369

RÉSUMÉ

Introduction: We propose a new facial lifting protocol using polydioxanone (PDO) threads embedded in acetyl hexapeptide-8 (Argireline [Arg]). We assume that Arg reinforces the effects of PDO threads, as it is a mimetic of botulinum toxin. Because the PDO suture is hydrolyzable, this assumption is analyzed by instrumental analysis. Objective: To demonstrate the capacity of the PDO suture as a system for the controlled release of acetyl hexapeptide-8 to apply in deep wrinkles of the upper third. Materials and Methods: Three segments of 1-cm long 21G PDO threads immersed in 1 mL of Arg. PDO threads were observed under an optical, electron microscope at 24, 48, and 72 h later. They were also weighed before and after being soaked in Arg, and employing ultraviolet (UV)-visible spectroscopy, the release rate of Arg from the PDO suture was measured. Finally, was insert the thread PDO-Arg following a protocol designed especially for deep static wrinkles in the upper third. Results: The electronic weighing revealed that the PDO thread enjoys capillarity by the peptide, doubling its weight every 24 h. UV spectra revealed that PDO thread is a well-controlled release system for Arg, allowing its sustained release for 1 h. Optical and electronic photomicrographs confirm the swelling of the PDO thread by absorbing Arg by its capillarity, but this hydrophilicity does not lead to its premature physical degradation. Conclusions: The PDO thread system with Arg is an intelligent bioactive system useful in facial harmonization. It recommend conduct clinical trial to verify his superior lifting effect.

8.
Polymers (Basel) ; 15(1)2022 Dec 21.
Article de Anglais | MEDLINE | ID: mdl-36616379

RÉSUMÉ

This study evaluated the bioactivity of 3D-printed ß-tricalcium phosphate (ß-TCP) scaffolds or hydroxyapatite (HA) scaffolds associated with polydioxanone (PDO) membrane (Plenum® Guide) for guided bone regeneration in rats. Fifty-four rats were divided into three groups (n = 18 animals): autogenous bone + PDO membrane (Auto/PG); 3D-printed ß-TCP + PDO membrane (TCP/PG); and 3D-printed HA + PDO membrane (HA/PG). A surgical defect in the parietal bone was made and filled with the respective scaffolds and PDO membrane. The animals were euthanized 7, 30, and 60 days after the surgical procedure for micro-CT, histomorphometric, and immunolabeling analyses. Micro-CT showed an increase in trabecular thickness and a decrease in trabecular separation, even with similar bone volume percentages between TCP/PG and HA/PG vs. Auto/PG. Histometric analysis showed increased bone formation at 30 days in the groups compared to 7 days postoperatively. Immunolabeling analysis showed an increase in proteins related to bone formation at 30 days, and both groups showed a similar immunolabeling pattern. This study concludes that 3D-printed scaffolds associated with PDO membrane (Plenum® Guide) present similar results to autogenous bone for bone regeneration.

9.
Araçatuba; s.n; 2022. 82 p. ilus, graf.
Thèse de Portugais | LILACS, BBO - Ondontologie | ID: biblio-1444755

RÉSUMÉ

O objetivo deste trabalho foi analisar o potencial bioativo de um "scaffold" de Polidioxanona (PDO) com associação da rhBMP-2, nas reconstruções após simulação de ressecção óssea em fêmures de ratos. Para tanto, 24 ratos, machos, adultos, com 6 meses de idade, foram submetidos a ressecção e reconstrução dos fêmures bilateralmente. Inicialmente foi realizada a estabilização com fixação de placas e parafusos de titânio do sistema 1.5mm e em seguida a confecção de um "gap" de 2mm. A reconstrução foi realizada com rhBMP-2 (Infuse) carreada em esponja de colágeno (3,25 µg), tendo uma malha de titânio, para o grupo Titânio (n=24 fêmures) (grupo controle), atuando como um arcabouço. E para o grupo PDO (n=24 fêmures) (grupo teste), a reconstrução foi realizada também com a rhBMP-2 carreada em uma esponja de colágeno (3,25 µg), envolvido por um "scaffold" de PDO. Desses animais, 16 (2 por tempo) receberam em seu dorso, no plano subcutâneo, um fragmento do mesmo material testado em seu fêmur, para análise de biocompatibilidade, que foram removidos sob anestesia local, junto de fragmento do tecido subcutâneo adjacente, aos 3, 5, 7 e 10 dias para análise. Os animais foram submetidos à eutanásia (n=6 por grupo) nos períodos de 14 e 60 dias após a cirurgia de reconstrução tiveram seus órgãos de metabolização (cérebro, rim, fígado e músculo) removidos para análise anatomopatológica e seus fêmures também foram removidos, reduzidos, radiografados para análise da densitometria radiográfica posteriormente os fêmures passaram por descalcificação e em seguida todas as peças foram submetidas ao processamento para obtenção de lâminas com cortes de 5 µm de espessura, para avaliação histológica, com avaliação da área óssea neoformada e perfil inflamatório e para análise imunohistoquimica através das proteínas Runx2, OPG, RANKL, OCN e BMP2. Todos os dados quantitativos foram submetidos ao teste ANOVA-2 fatores e quando p< 0,05, o pós-teste Tukey foi realizado. Os resultados da densitometria radiográfica demonstraram maior densidade para o grupo PDO, especialmente no período de 14 dias (p< 0,05). Na análise histológica observou-se reparo mais favorável para o grupo PDO, especialmente aos 60 dias quando comparado ao Titânio, com diferença estatística significativa (p = 0.002) bem como menor infiltrado inflamatório e maior número de vasos sanguíneos aos 14 dias. Com relação as imunomarcações, BMP-2 não apresentou marcações para Titânio e dados expressivos para PDO, com diferença significativamente estatística aos 60 dias (p< 0.05). OPG e RANKL mostraram maior marcação para titânio, principalmente aos 60 dias (p< 0.05). Já Runx2 e OCN apresentaram resultados superiores para PDO aos 14 dias, entretanto, aos 60 dias titânio demonstrou maior expressão. A análise de biocompatibilidade mostrou maior processo inflamatório para o grupo titânio. Os órgãos de metabolização apresentaram aspectos de higidez dentro da normalidade para ambos grupos. Os resultados deste trabalho demonstram um padrão reparacional mais favorável à associação do "Scaffold" de PDO com a rhBMP-2, quando comparado a reconstrução com malha de titânio(AU)


The objective of this work was to analyze the bioactive potential of a Polydioxanone (PDO) scaffold with rhBMP-2 association, in reconstructions after simulating bone resection in rat femurs. Therefore, 24 male, adult rats, aged 6 months, underwent resection and reconstruction of the femurs bilaterally. Initially, stabilization was performed with fixation of titanium plates and screws of the 1.5mm system and then a 2mm gap was created. The reconstruction was performed with rhBMP-2 (Infuse) loaded in a collagen sponge (3.25 µg), with a titanium mesh, for the Titanium group (n=24 femurs) (control group), acting as a scaffold. And for the PDO group (n=24 femurs) (test group), the reconstruction was also performed with rhBMP-2 carried in a collagen sponge (3.25 µg), surrounded by a PDO scaffold. Of these animals, 16 (2 per time) received on their back, in the subcutaneous plane, a fragment of the same material tested in their femur, for biocompatibility analysis, which was removed under local anesthesia, together with a fragment of the adjacent subcutaneous tissue, at 3, 5, 7 and 10 days for analysis. The animals were euthanized (n=6 per group) in the periods of 14 and 60 days after the reconstruction surgery, had their metabolizing organs (brain, kidney, liver, and muscle) removed for anatomopathological analysis and their femurs were also removed, reduced, radiographed for analysis of radiographic densitometry later the femurs underwent decalcification and then all the pieces were submitted to processing to obtain 5 µm thick slices for histological evaluation, with the evaluation of the newly formed bone area and inflammatory profile and for immunohistochemical analysis through Runx2, OPG, RANKL, OCN, and BMP2 proteins. All quantitative data were submitted to the 2-way ANOVA test and when p< 0.05, the Tukey post-test was performed. The results of radiographic densitometry showed higher density for the PDO group, especially in the 14-day period (p< 0.05). In the histological analysis, a more favorable repair was observed for the PDO group, especially at 60 days when compared to Titanium, with a statistically significant difference (p = 0.002), as well as a lower inflammatory, infiltrate and a greater number of blood vessels at 14 days. Regarding immunostaining, BMP-2 did not show staining for Titanium and expressive data for PDO, with a statistically significant difference at 60 days (p< 0.05). OPG and RANKL showed higher staining for titanium, mainly at 60 days (p< 0.05). On the other hand, Runx2 and OCN showed superior results for PDO at 14 days, however, at 60 days titanium showed greater expression. The biocompatibility analysis showed a greater inflammatory process for the titanium group. The metabolizing organs presented aspects of health within the normal range for both groups. The results of this work demonstrate a more favorable repair pattern for the association of the PDO scaffold with rhBMP-2, when compared to reconstruction with titanium mesh(AU)


Sujet(s)
Animaux , Rats , Régénération osseuse , Protéine morphogénétique osseuse de type 2 , Polymères , Rat Wistar , Protéines morphogénétiques osseuses
10.
Polymers (Basel) ; 13(11)2021 May 21.
Article de Anglais | MEDLINE | ID: mdl-34064251

RÉSUMÉ

Resorbable synthetic and natural polymer-based membranes have been extensively studied for guided tissue regeneration. Alloplastic biomaterials are often used for tissue regeneration due to their lower immunoreactivity when compared with allogeneic and xenogeneic materials. Plenum® Guide is a synthetic membrane material based on polydioxanone (PDO), whose surface morphology closely mimics the extracellular matrix. In this study, Plenum® Guide was compared with collagen membranes as a barrier material for bone-tissue regeneration in terms of acute and subchronic systemic toxicity. Moreover, characterizations such as morphology, thermal analysis (Tm = 107.35 °C and crystallinity degree = 52.86 ± 2.97 %, final product), swelling (thickness: 0.25 mm ≅ 436% and 0.5 mm ≅ 425% within 24 h), and mechanical tests (E = 30.1 ± 6.25 MPa; σ = 3.92 ± 0.28 MPa; ε = 287.96 ± 34.68%, final product) were performed. The in vivo results revealed that the PDO membranes induced a slightly higher quantity of newly formed bone tissue than the control group (score: treated group = 15, control group = 13) without detectable systemic toxicity (clinical signs and evaluation of the membranes after necropsy did not result in differences between groups, i.e., non-reaction -> tissue-reaction index = 1.3), showing that these synthetic membranes have the essential characteristics for an effective tissue regeneration. Human adipose-derived stem cells (hASCs) were seeded on PDO membranes; results demonstrated efficient cell migration, adhesion, spread, and proliferation, such that there was a slightly better hASC osteogenic differentiation on PDO than on collagen membranes. Hence, Plenum® Guide membranes are a safe and efficient alternative for resorbable membranes for tissue regeneration.

11.
J Cutan Aesthet Surg ; 12(2): 145-148, 2019.
Article de Anglais | MEDLINE | ID: mdl-31413486

RÉSUMÉ

Recently, some clinicians have proposed implanting polydioxanone (PDO) threads imbibed in hyaluronic acid (HA), arguing that this may reinforce the lifting effects. However, this is controversial because PDO sutures are hydrophilic and the presence of HA could increase the rate of hydrolysis. The aim of this study was to demonstrate the degradation of PDO lifting threads in HA through ultramicroscopy. It was a qualitative research and preclinical trial. Three, 1-cm-long, segments of 23-G PDO threads were immersed in 1.5-mL non-crosslinked HA in previously labeled, sterile microcentrifuge tubes. These were observed by ultramicroscopy at 4× and 10× after 24, 48, and 72 h. Microphotographs taken after 24 h show structural changes in the fibers, presenting an increase in interlaminar spaces and dilution of violet pigmentation. At 48 h, degradation continues. PDO hygroscopy is observed as aqueous content between the peripheral layers and the central core of the thread. At 72 h, as the pigment is released, larger empty spaces are observed in the central column of the thread, and there is disorganization of the peripheral fibrils with fraying all along the fiber. HA induces rapid biodegradation of the PDO thread by hydrolysis beginning 24 h after contact of the thread with the biomaterial. The non-crosslinked HA is a powerful catalyzing agent for hydrolytic degradation of the PDO thread, because this thread is highly hydrophilic. Clinically, embedding PDO threads in HA accelerates biodegradation of the suture.

12.
Medwave ; 19(1): e7575, 2019 Jan 31.
Article de Espagnol, Anglais | MEDLINE | ID: mdl-31100753

RÉSUMÉ

We present the case of a female patient with complications from superficial implantation of polydioxanone spiculated threads in the facial middle third. The manifestations were edema, ecchymosis, superficial palpation of the thread and skin plication. For the treatment we propose a novel protocol of clinical degradation of polydioxanone threads, using hyaluronic acid injecting it into the implantation area of the polydioxanone threads. Non-cross linked hyaluronic acid was infiltrated along the path of the thread. The follow-up at seven, 21 and 45 days showed decreased edema, folds and skin irregularities due to wire traction and attenuation of secondary rhytides. A sample of the thread in hyaluronic acid was observed in a laminar flow campaign evidencing degradation at 72 hours. Administering hyaluronic acid was effective in inducing clinical biodegradation of the thread suggesting that non-crosslinked hyaluronic acid is a powerful catalyst for the hydrolytic degradation of polydioxanone.


Se expone el caso de una paciente remitida por complicaciones posteriores a la implantación superficial en el tercio medio facial de hilos de polidioxanona espiculados. Presentaba edema, equimosis, palpación superficial del hilo y plicación dérmica. Para el tratamiento planteamos un novedoso protocolo de degradación clínica de hilos de polidioxanona, empleando ácido hialurónico inyectándolo en el área de su implantación. Se infiltró ácido hialurónico no reticulado en el trayecto a lo largo del recorrido del hilo. El seguimiento a los siete, 21 y 45 días evidenció disminución del edema, de los pliegues e irregularidades dérmicas por la tracción del hilo y atenuación de rítides secundarias. Una muestra del hilo en ácido hialurónico fue observado en campana de flujo laminar evidenciándose degradación a las 72 horas. Administrar ácido hialurónico fue efectivo para inducir la biodegradación clínica del hilo. La hipótesis derivada sugiere que el ácido hialurónico no reticulado es un poderoso catalizador de la degradación hidrolítica de la polidioxanona.


Sujet(s)
Acide hyaluronique/composition chimique , Polydioxanone/effets indésirables , Rhytidoplastie/effets indésirables , Adulte , Femelle , Études de suivi , Humains , Microscopie/méthodes , Polydioxanone/composition chimique , Rhytidoplastie/méthodes , Vieillissement de la peau
13.
Medwave ; 19(1)2019.
Article de Anglais, Espagnol | LILACS | ID: biblio-980833

RÉSUMÉ

Se expone el caso de una paciente remitida por complicaciones posteriores a la implantación superficial en el tercio medio facial de hilos de polidioxanona espiculados. Presentaba edema, equimosis, palpación superficial del hilo y plicación dérmica. Para el tratamiento planteamos un novedoso protocolo de degradación clínica de hilos de polidioxanona, empleando ácido hialurónico inyectándolo en el área de su implantación. Se infiltró ácido hialurónico no reticulado en el trayecto a lo largo del recorrido del hilo. El seguimiento a los siete, 21 y 45 días evidenció disminución del edema, de los pliegues e irregularidades dérmicas por la tracción del hilo y atenuación de rítides secundarias. Una muestra del hilo en ácido hialurónico fue observado en campana de flujo laminar evidenciándose degradación a las 72 horas. Administrar ácido hialurónico fue efectivo para inducir la biodegradación clínica del hilo. La hipótesis derivada sugiere que el ácido hialurónico no reticulado es un poderoso catalizador de la degradación hidrolítica de la polidioxanona.


We present the case of a female patient with complications from superficial implantation of polydioxanone spiculated threads in the facial middle third. The manifestations were edema, ecchymosis, superficial palpation of the thread and skin plication. For the treatment we propose a novel protocol of clinical degradation of polydioxanone threads, using hyaluronic acid injecting it into the implantation area of the polydioxanone threads. Non-cross linked hyaluronic acid was infiltrated along the path of the thread. The follow-up at seven, 21 and 45 days showed decreased edema, folds and skin irregularities due to wire traction and attenuation of secondary rhytides. A sample of the thread in hyaluronic acid was observed in a laminar flow campaign evidencing degradation at 72 hours. Administering hyaluronic acid was effective in inducing clinical biodegradation of the thread suggesting that non-crosslinked hyaluronic acid is a powerful catalyst for the hydrolytic degradation of polydioxanone.


Sujet(s)
Humains , Femelle , Adulte , Rhytidoplastie/effets indésirables , Polydioxanone/effets indésirables , Acide hyaluronique/composition chimique , Rhytidoplastie/méthodes , Vieillissement de la peau , Études de suivi , Polydioxanone/composition chimique , Microscopie/méthodes
14.
J. coloproctol. (Rio J., Impr.) ; 37(4): 263-267, Oct.-Dec. 2017. tab, graf
Article de Anglais | LILACS | ID: biblio-894008

RÉSUMÉ

ABSTRACT Introduction: Intestinal anastomosis is a surgical practice constantly realized by surgeons worldwide. When the option is to perform manual anastomosis, which is still widely used for its low cost, the question arises as to the best material to be applied. Objective: To compare polydioxanone and polyglactin threads for healing and tensile strength in intestinal anastomosis in rats. Method: We used 25 rats Wistar; after anesthesia, in groups A and B (10 rats each), laparotomy was performed, transection of the ileum at 5 and 10 cm proximally to the ileocecal valve; in group A, anastomosis was performed with 4 separate extra mucosal sutures with polidioxanone; in group B, anastomosis was performed with polyglactin; in group C (5 rats), laparotomy and manipulation of the ileum were performed. After 21 days, the animals were anesthetized and submitted to euthanasia. The specimens were sent for histopathological study and tensile strength analysis. Statistical analysis was performed using the Turkey and Student's t tests, with a significance of p < 0.05. Results: The results showed that in the tensile strength analysis, there were no significant differences between them. The histological analysis showed significant differences between the cicatrization pattern, where polydioxanone caused less fibrosis than polyglactin. Conclusion: Polydioxanone caused less fibrosis than polyglactin in intestinal anastomoses of rats.


RESUMO Introdução: Anastomose intestinal é uma prática cirúrgica constantemente realizada pelos cirurgiões em todo o mundo. Quando a opção é a anastomose manual - um procedimento ainda amplamente empregado, graças a seu baixo custo - coloca-se o problema de saber qual é o melhor material a ser aplicado. Objetivo: Comparar fios de polidioxanona e poliglactina quanto à cicatrização e resistência à tração em anastomoses intestinais em ratos. Método: Utilizamos 25 ratos Wistar; depois da anestesia, foi realizada laparotomia nos grupos A e B (10 ratos cada), com transecção do íleo a 5 e 10 centímetros proximalmente à válvula ileocecal; no grupo A, a anastomose foi realizada com 4 suturas de mucosa separadas com uso de polidioxanona; no grupo B, a anastomose foi realizada com poliglactina; no grupo C (5 ratos), foi realizada apenas a laparotomia e manipulação do íleo. Transcorridos 21 dias, os ratos foram anestesiados e submetidos à eutanásia. Os espécimes foram enviados para estudo histopatológico e análise de resistência à tração. A análise estatística foi efetuada com a aplicação dos testes de Tukey e de t de Student, com significância de p < 0,05. Resultados: Os resultados demonstraram que, na análise de resistência à tração, não foram observadas diferenças significativas entre os materiais. A análise histológica revelou diferenças significativas entre padrões de cicatrização, em que polidioxanona causou menos fibrose versus poliglactina. Conclusão: Polidioxanona causou menos fibrose versus poliglactina em anastomoses intestinais realizadas em ratos.


Sujet(s)
Animaux , Rats , Polyglactine 910 , Polydioxanone , Intestin grêle/chirurgie , Résistance à la traction , Cicatrisation de plaie , Anastomose chirurgicale , Rat Wistar
15.
Full dent. sci ; 8(32): 102-110, 2017. ilus
Article de Portugais | BBO - Ondontologie | ID: biblio-948153

RÉSUMÉ

Diversas técnicas de rejuvenescimento têm sido a alternativa terapêutica de pacientes que buscam por um rejuvenescimento facial. O lifting facial com o uso de fios de sustentação é uma técnica minimamente invasiva e apresenta ótimos resultados pós-operatórios. Para isso, materiais reabsorvíveis têm sido preferencialmente usados. Entre eles, citamos o fio de polidioxanona (PDO), um polímero sintético, biodegradável e com baixa reação inflamatória entre o tecido e o fio. Fornece suporte e estimula os tecidos das áreas ao redor do defeito estético através da produção de colágeno, assim, neutralizando os efeitos do envelhecimento. Este trabalho tem como finalidade mostrar as mudanças ocasionadas após a inserção do fio na face química e fisicamente, relatar um caso em que o fio de polidioxanona foi utilizado na harmonização facial e apresentar suas vantagens, desvantagens e indicações (AU).


Several techniques of rejuvenation have been a therapeutic alternative for patients who seek facial rejuvenation. The facelift with the use of support threads is a minimally invasive technique that provides excellent postoperative results. For this, resorbable materials have been preferably used. Between them, we quote the polydioxanona thread (PDO), a synthetic and biodegradable polymer and a low inflammable reaction between the tissue and the thread which provides the support and stimulates the tissues of the areas around the aesthetic defect for the production of collagen, neutralizing the effects of aging. This work aims to show how the changes caused due to the insertion of the thread on the face chemically and physically, report a case which the polydioxanone thread was used in facial harmonization, and then present its advantages, disadvantages, and indications (AU).


Sujet(s)
Humains , Femelle , Adulte d'âge moyen , Réadaptation , Rajeunissement , Polydioxanone , Dentisterie esthétique , Brésil , Vieillissement de la peau
16.
Rev. bras. cir. plást ; 31(4): 516-521, 2016. ilus, tab
Article de Anglais, Portugais | LILACS | ID: biblio-827438

RÉSUMÉ

Introduction: Plication of the rectus abdominis muscle is an important step in remodeling the abdomen in abdominoplasties. It can be performed using several types of threads with interrupted or continuous sutures, according to the surgeon's preferences. Few studies in the literature compared the different plication techniques in abdominoplasties. The present study aimed to compare continuous anchored suture with polydioxanone (PDS) with interrupted nylon suture regarding surgical time, relapse, and costs and discuss the advantages and disadvantages of each method. Methods: A randomized clinical trial in which 30 patients were enrolled for each of the two groups, 15 with continuous suture and 15 with interrupted suture, was conducted. The plication time was compared between the groups using the Student's t-test. Between 10 and 12 months postoperatively, all patients underwent ultrasonography for investigating diastasis recurrence. Results: Continuous suture decreased the plication time by almost 40% when compared to the interrupted suture (p < 0.001), without affecting the esthetic outcome. The PDS used in the continuous suture implied higher costs than those with the nylon threads used in the interrupted suture. No recurrence was found on the postoperative control ultrasonography results. Conclusion: Continuous suture reduced the plication time by almost 40% (p < 0.001) when compared to interrupted suture. Despite being associated with higher costs, PDS seems to be a good alternative to non-absorbable sutures, such as nylon threads, in plications of the rectus abdominis, since it is a more biocompatible material.


Introdução: A plicatura do músculo reto abdominal é um passo importante no remodelamento do abdômen nas abdominoplastias. Ela pode ser realizada com vários tipos de fios e com suturas interrompidas ou contínuas, de acordo com as preferências do cirurgião. Poucos estudos na literatura compararam diferentes técnicas de plicatura nas abdominoplastias. O objetivo do estudo é comparar a sutura contínua ancorada com polidioxanona (PDS) com a sutura interrompida com náilon quanto ao tempo cirúrgico, recidiva, custos e discutir vantagens de desvantagens de cada método. Métodos: Ensaio clínico randomizado no qual 30 pacientes foram arroladas para cada um dos grupos, 15 sutura contínua e 15 sutura interrompida. O tempo de plicatura foi comparado entre os grupos utilizando-se o teste t de Student. Entre 10 a 12 meses de pós-operatório, todas as pacientes foram submetidas à ecografia em busca de recidivas da diástase. Resultados: A sutura contínua diminuiu em quase 40% o tempo de plicatura quando comparada à sutura interrompida (p < 0,001), sem prejuízo no resultado estético. O PDS utilizado na sutura contínua implicou maiores custos que os fios de náilon utilizados na sutura interrompida. Nenhuma recidiva foi encontrada na ecografia de controle no pós-operatório. Conclusão: A sutura contínua quando comparada à sutura interrompida foi capaz de reduzir o tempo de plicatura em quase 40% (p < 0,001). A utilização do PDS, apesar dos maiores custos, parece ser uma boa alternativa às suturas com fios não absorvíveis como o náilon nas plicaturas do músculo reto abdominal, uma vez que se trata de um fio de maior biocompatibilidade.


Sujet(s)
Humains , Femelle , Adulte d'âge moyen , Sujet âgé , Histoire du 21ème siècle , Récidive , Matériaux de suture , Techniques de suture , Essai contrôlé randomisé , Polydioxanone , Muscle droit de l'abdomen , Abdomen , Amylases , Nylons , Matériaux biocompatibles , Matériaux biocompatibles/analyse , Matériaux biocompatibles/usage thérapeutique , Techniques de suture/normes , Polydioxanone/usage thérapeutique , Muscle droit de l'abdomen/chirurgie , Abdominoplastie , Abdominoplastie/méthodes , Abdomen/chirurgie , Amylases/usage thérapeutique , Nylons/analyse , Nylons/normes
17.
Int. arch. otorhinolaryngol. (Impr.) ; 18(2): 92-107, Apr-Jun/2014.
Article de Anglais | LILACS | ID: lil-711680

RÉSUMÉ

Introduction: Several surgical techniques emphasizing sutures on the lower lateral cartilage have been studied by surgeons as instruments to improve nasal tip remodeling. It is already known that the domal divergence angle and its definition angle can be modified by lateral intercrural suture (LIS). Techniques for measuring these structures are not yet standardized. Objectives: Assess the efficacy of LIS using polydioxanone 4–0 absorbable thread by interdomal distance and systematize the LIS technique to improve nasal tip definition. Materials and Methods: This prospective study measured and analyzed interdomal distances measured preoperatively and perioperatively compared with 3- and 6-month postoperative measurements. Results: LIS was efficient on reducing interdomal distances. Conclusion: LIS is statistically safe and efficient and has low morbidity when utilized in patients with mild to moderate deformities, because it reduces the domal divergence angle, effectively sustaining the nasal tip...


Sujet(s)
Humains , Femelle , Adulte , Procédures chirurgicales du nez , Rhinoplastie , Techniques de suture
18.
Int Arch Otorhinolaryngol ; 18(2): 92-107, 2014 Apr.
Article de Anglais | MEDLINE | ID: mdl-25992073

RÉSUMÉ

Introduction Several surgical techniques emphasizing sutures on the lower lateral cartilage have been studied by surgeons as instruments to improve nasal tip remodeling. It is already known that the domal divergence angle and its definition angle can be modified by lateral intercrural suture (LIS). Techniques for measuring these structures are not yet standardized. Objectives Assess the efficacy of LIS using polydioxanone 4-0 absorbable thread by interdomal distance and systematize the LIS technique to improve nasal tip definition. Materials and Methods This prospective study measured and analyzed interdomal distances measured preoperatively and perioperatively compared with 3- and 6-month postoperative measurements. Results LIS was efficient on reducing interdomal distances. Conclusion LIS is statistically safe and efficient and has low morbidity when utilized in patients with mild to moderate deformities, because it reduces the domal divergence angle, effectively sustaining the nasal tip.

19.
Acta cir. bras. ; 18(5)2003.
Article de Portugais | VETINDEX | ID: vti-448499

RÉSUMÉ

PURPOSE: To assess the arterial suture, comparing continuous and interrupted techniques, in abdominal aorta of growing rabbbits, using two types of suture material: Polypropylene 7-0 (nonabsorbable) and Polydioxanone 7-0 (absorbable). METHODS: Groups: GI - Control, without arterial suture; GII - Polypropylene, Interrupted technique; GIII - Polipropilene, Continuous technique; GIV - Polydioxanone, Interrupted technique and GV - Polydioxanone, Continuous technique. Each group was subdivided in four Moments of Euthanasia , according with the number of days after surgery: 7 , 14 , 30 and 60 days. The following itens were assessed: weight, arterial diameters and pulse, stenosis, thrombosis, tissue adherence at the suture line, aortography, suture material visibility, suture line healling visibility and microscopic study. RESULTS: a) after 60 days, the suture line site had a significant growing in all groups; b) interrupted technique result less suture line stenosis in surgical act and in euthanasia c) the difference between groups showed in the microscopic study, was transitory, not pesisting after 60 days post surgery; CONCLUSION: Polydioxanone is better than polypropylene for suture in growing artery, not causing (or causing little) restriction to the growing of the suture line, even though using continuous technique.


OBJETIVO: Observar o comportamento da sutura arterial em aortas abdominais de coelhos em crescimento, comparando-se as técnicas contínua e com pontos separados, empregando-se dois tipos de fios: Polipropilene 7-0 (inabsorvível) e Polidioxanone 7-0 (absorvível). MÉTODOS: Grupos: GI - Controle (sem sutura); GII - Polipropilene, Pontos Separados; GIII - Polipropilene, Contínua; GIV - Polidioxanone, Pontos Separados e GV - Polidioxanone, Contínua. Cada grupo foi subdividido em quatro Momentos de Eutanásia: aos 7, 14, 30 e 60 dias de pós-operatório. Foram avaliados: peso dos animais, diâmetros e pulsos arteriais, estenose, trombose, aderências, aortografia, visibilidade do fio, cicatrização e microscopia. RESULTADOS: a) após 60 dias, o local da linha de sutura cresceu de forma significativa em todos os grupos; b) a técnica de sutura com pontos separados causou menor estenose da linha de sutura, observada tanto no ato cirúrgico, como na eutanásia dos animais; c) no exame histopatológico, as diferenças encontradas entre grupos foram transitórias, não persistindo após 60 dias de pós-operatório. CONCLUSÃO: O polidioxanone mostrou ser a melhor opção, entre os dois fios, para sutura de artérias em crescimento, pois causa pouca ou nenhuma restrição ao crescimento arterial na linha de sutura, mesmo quando se emprega a técnica contínua.

SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE