1.
Arch Bone Jt Surg ; 10(9): 806-811, 2022 Sep.
Article de Anglais | MEDLINE | ID: mdl-36246023

RÉSUMÉ

The treatment of culture-negative periprosthetic joint infections (CN PJI) of the hip represents complex entities. We, as a result of this, report on 12 cases. Irrigation and debridement (I&D) with implant retention were performed in acute cases and two-stage revisions in chronic infections. Combined antibiotic therapy was administered in all cases for 12 weeks. Infection control was achieved in all patients with an infection-free rate of 100% at 7.5 years of average follow-up.

2.
J Arthroplasty ; 36(7S): S80-S87, 2021 07.
Article de Anglais | MEDLINE | ID: mdl-33610405

RÉSUMÉ

BACKGROUND: Dual mobility (DM) articulations were introduced for total hip arthroplasty to reduce the risk of instability for patients who have a high risk of dislocation. The use of DM constructs in both primary and revision total hip arthroplasty has been steadily increasing, leading to concerns regarding potential risks of fretting corrosion, polyethylene wear, metal release, and failure due to component positioning. METHODS: A total of 56 retrieved DM constructs were collected. The inner and outer polyethylene liner surfaces were assessed for 7 damage mechanisms, and fretting corrosion was evaluated for the femoral stem, head, and modular liner. Three polyethylene liners with the greatest amounts of embedded debris were examined using scanning electron microscopy. Energy-dispersive X-ray spectroscopy was used to determine the elemental content of the debris. Acetabular cup orientation was analyzed radiographically using the EBRA (Einzel-Bild-Roentgen-Analyse) method. RESULTS: The devices were revised most frequently for infection (36%), loosening (21%), and instability/dislocation (18%). The most common polyethylene damage mechanisms were scratching, pitting, burnishing, and embedded debris, and no difference in total damage was found between primary and revision cases. Scanning electron microscopy/energy-dispersive X-ray spectroscopy revealed that debris morphology and composition were consistent with porous titanium coating, resulting from cup loosening or broken screws and augments. A total of 71% and 50% of the constructs were determined to be within the Lewinnek safe zone for inclination and anteversion, respectively. CONCLUSION: The most notable mechanisms of surface damage were due to third-body debris, especially for the polyethylene surfaces which articulate against cobalt-chromium femoral heads and acetabular liners. Scratching of the femoral head and the metal liner from this debris may support the clinical use of ceramic for DM bearing surfaces in the future.


Sujet(s)
Arthroplastie prothétique de hanche , Prothèse de hanche , Arthroplastie prothétique de hanche/effets indésirables , Corrosion , Prothèse de hanche/effets indésirables , Humains , Polyéthylène , Conception de prothèse , Défaillance de prothèse
3.
Lasers Med Sci ; 33(9): 1933-1940, 2018 Dec.
Article de Anglais | MEDLINE | ID: mdl-29909435

RÉSUMÉ

When conservative treatments fail, hip osteoarthritis (OA), a chronic degenerative disease characterized by cartilage wear, progressive joint deformity, and loss of function, can result in the need for a total hip arthroplasty (THA). Surgical procedures induced tissue trauma and incite an immune response. Photobiomodulation therapy (PBMt) using low-level laser therapy (LLLT) and/or light-emitting diode therapy (LEDT) has proven effective in tissue repair by modulating the inflammatory process and promoting pain relief. Therefore, the aim of this study was to analyze the immediate effect of PBMt on inflammation and pain of patients undergoing total hip arthroplasty. The study consisted of 18 post-surgical hip arthroplasty patients divided into two groups (n = 9 each) placebo and active PBMt who received one of the treatments in a period from 8 to 12 h following THA surgery. PBMt (active or placebo) was applied using a device consisting of nine diodes (one super-pulsed laser of 905 nm, four infrared LEDs of 875 nm, and four red LEDs 640 nm, 40.3 J per point) applied to 5 points along the incision. Visual analog scale (VAS) and blood samples for analysis of the levels of the cytokines TNF-α, IL-6, and IL-8 were recorded before and after PBMt application. The values for the visual analog scale as well as those in the analysis of TNF-α and IL-8 serum levels decreased in the active PBMt group compared to placebo-control group (p < 0.05). No decrease was observed for IL-6 levels. We conclude that PBMt is effective in decreasing pain intensity and post-surgery inflammation in patients receiving total hip arthroplasty.


Sujet(s)
Douleur aigüe/radiothérapie , Arthroplastie prothétique de hanche/effets indésirables , Inflammation/radiothérapie , Photothérapie de faible intensité , Sujet âgé , Femelle , Humains , Interleukine-6/métabolisme , Mâle , Mesure de la douleur , Placebo , Facteur de nécrose tumorale alpha/métabolisme