Résultats 1 - 19 de 19
Filtrer
1.
Rev Assoc Med Bras (1992) ; 64(4): 330-338, 2018 Apr.
Article de Anglais | MEDLINE | ID: mdl-30133612

RÉSUMÉ

OBJECTIVE: The current study was aimed to examine intra-individual variation on indicators of bone health in addition to whole-body plus appendicular tissue measurements using two concurrent assessments based on pencil beam and fan beam dual energy X-ray absorptiometry (DXA) systems in adult athletes from several sports. METHOD: Thirty-two male participants (27.6±10.1 years) were measured on anthropometry including multifrequency bioelectric impedance and air-displacement plethysmography. Bone mineral content (BMC), bone area, fat and lean soft tissue were derived using pencil beam (Lunar DPX-MD+) and fan beam (Lunar iDXA) absorptiometry. Bone mineral density (BMD) was obtained for the femoral neck, trochanter and triangle of ward. Finally, the right thigh was defined as a region of interest (ROI). Analyses comprised intra-class correlation (ICC), Effect size (d) from mean differences of repeated measurements, coefficient of variation (CV). RESULTS: ICC were >0.900 for all measurements. Intra-individual differences were large for BMC (d=1,312; CV=2,7%), bone area (d=1,761; CV=2,7%), fat tissue (d=1,612; CV=11%) and all indicators of appendicular lean soft tissue (d=1,237-1687; CV=2,0-4,1%). A very large difference (d=4,014; CV=8.4%) was diagnosed for lean soft tissue of the ROI. CONCLUSION: Although differences among concurrent instruments for BMC and bone area, the effect size of mean differences was negligible for BMD. Fat and lean soft tissue derived from DXA should be interpreted as reference values (not criterion) due to equipment-related variation, more apparently in the ROI values.


Sujet(s)
Absorptiométrie photonique/instrumentation , Athlètes , Composition corporelle , Densité osseuse , Os et tissu osseux/imagerie diagnostique , Adolescent , Adulte , Anthropométrie , Études transversales , Impédance électrique , Humains , Mâle , Adulte d'âge moyen , Pléthysmographie/méthodes , Valeurs de référence , Reproductibilité des résultats , Statistique non paramétrique , Jeune adulte
2.
Rev. Assoc. Med. Bras. (1992, Impr.) ; Rev. Assoc. Med. Bras. (1992, Impr.);64(4): 330-338, Apr. 2018. tab, graf
Article de Anglais | LILACS | ID: biblio-956459

RÉSUMÉ

SUMMARY OBJECTIVE: The current study was aimed to examine intra-individual variation on indicators of bone health in addition to whole-body plus appendicular tissue measurements using two concurrent assessments based on pencil beam and fan beam dual energy X-ray absorptiometry (DXA) systems in adult athletes from several sports. METHOD: Thirty-two male participants (27.6±10.1 years) were measured on anthropometry including multifrequency bioelectric impedance and air-displacement plethysmography. Bone mineral content (BMC), bone area, fat and lean soft tissue were derived using pencil beam (Lunar DPX-MD+) and fan beam (Lunar iDXA) absorptiometry. Bone mineral density (BMD) was obtained for the femoral neck, trochanter and triangle of ward. Finally, the right thigh was defined as a region of interest (ROI). Analyses comprised intra-class correlation (ICC), Effect size (d) from mean differences of repeated measurements, coefficient of variation (CV) RESULTS: ICC were >0.900 for all measurements. Intra-individual differences were large for BMC (d=1,312; CV=2,7%), bone area (d=1,761; CV=2,7%), fat tissue (d=1,612; CV=11%) and all indicators of appendicular lean soft tissue (d=1,237-1687; CV=2,0-4,1%). A very large difference (d=4,014; CV=8.4%) was diagnosed for lean soft tissue of the ROI. CONCLUSION: Although differences among concurrent instruments for BMC and bone area, the effect size of mean differences was negligible for BMD. Fat and lean soft tissue derived from DXA should be interpreted as reference values (not criterion) due to equipment-related variation, more apparently in the ROI values.


RESUMO OBJETIVO: O presente estudo examinou a concordância entre os indicadores de saúde óssea e composição tecidual resultantes da aplicação de equipamentos concorrentes de absorciometria de raios X de dupla energia (DXA). MÉTODO: A amostra (n = 32), com 27,6 ± 10,1 anos de idade avaliados antropometricamente, inclui impedância bioelétrica com multifrequência e pletismografia de ar deslocado. O conteúdo mineral ósseo (CMO), a área de tecido ósseo, o tecido magro e o tecido gordo de corpo inteiro foram obtidos considerando o modo pencil beam (Lunar DPX-MD+) e o fan beam (Lunar iDXA). Para cada um dos equipamentos, foi efetuado um scanner proximal do fêmur, sendo produzida informação sobre a densidade mineral óssea (DMO) do colo, nomeadamente triângulo de Ward, trocanter e haste. Na fase de processamento, foi definida uma região de interesse (ROI; coxa direita). As análises compreenderam a diferença de médias de medidas repetidas com cálculo da magnitude de efeitos (d), coeficiente de correlação intraclasse (CCI), coeficiente de variação (CV). RESULTADOS: Foram obtidos CCI>0,900 para todas as medidas, com diferenças intraindividuais largas apenas para CMO (d = 1,312; CV = 2,7%), área de tecido ósseo (d = 1,761; CV = 2,7%), tecido gordo total (d = 1,612; CV = 11%) e tecido magro em todos os segmentos (d = 1,237-1,687; CV = 2,0-41%). A massa magra da ROI apresentou uma variaçāo intraindividual muito larga (d = 4,014; CV = 8,4%). CONCLUSÃO: Foram encontradas diferenças negligenciáveis para a DMO de corpo todo. As medidas de massa gorda e massa magra obtidas por DXA nāo devem ser tidas como critério, mas antes como referenda, muito especialmente quando se delimita uma ROI.


Sujet(s)
Humains , Mâle , Adolescent , Adulte , Jeune adulte , Composition corporelle , Os et tissu osseux/imagerie diagnostique , Absorptiométrie photonique/instrumentation , Densité osseuse , Athlètes , Adulte d'âge moyen , Pléthysmographie/méthodes , Valeurs de référence , Anthropométrie , Études transversales , Reproductibilité des résultats , Impédance électrique , Statistique non paramétrique
3.
Arch Endocrinol Metab ; 61(4): 354-360, 2017.
Article de Anglais | MEDLINE | ID: mdl-28977210

RÉSUMÉ

OBJECTIVES: To analyze the role of moderate-to-vigorous physical activity (MVPA) in mediating the relationship between central adiposity and immune and metabolic profile in postmenopausal women. MATERIALS AND METHODS: Cross-sectional study comprising 49 postmenopausal women (aged 59.26 ± 8.32 years) without regular physical exercise practice. Body composition was measured by dual-energy X-ray absorptiometry. Fasting blood samples were collected for assessment of nonesterified fatty acids, tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6), adiponectin, insulin and estimation of insulin resistance (HOMA-IR). Physical activity level was assessed with an accelerometer (Actigraph GTX3x) and reported as a percentage of time spent in sedentary behavior and MVPA. All analyses were performed using the software SPSS 17.0, with a significance level set at 5%. RESULTS: Sedentary women had a positive relationship between trunk fat and IL-6 (rho = 0.471; p = 0.020), and trunk fat and HOMA-IR (rho = 0.418; p = 0.042). Adiponectin and fat mass (%) were only positively correlated in physically active women (rho = 0.441; p = 0.027). Physically active women with normal trunk fat values presented a 14.7% lower chance of having increased HOMA-IR levels (ß [95%CI] = 0.147 [0.027; 0.811]). CONCLUSIONS: The practice of sufficient levels of MVPA was a protective factor against immunometabolic disorders in postmenopausal women.


Sujet(s)
Exercice physique , Interleukine-6/sang , Obésité abdominale/sang , Post-ménopause/métabolisme , Graisse abdominale/métabolisme , Absorptiométrie photonique/instrumentation , Adiponectine/sang , Adiposité , Sujet âgé , Composition corporelle , Études transversales , Jeûne/sang , Acides gras/sang , Femelle , Hormone folliculostimulante/sang , Humains , Insulinorésistance , Adulte d'âge moyen , Post-ménopause/sang , Facteurs de protection , Mode de vie sédentaire
4.
Arch. endocrinol. metab. (Online) ; 61(4): 354-360, July-Aug. 2017. tab, graf
Article de Anglais | LILACS | ID: biblio-887572

RÉSUMÉ

ABSTRACT Objectives To analyze the role of moderate-to-vigorous physical activity (MVPA) in mediating the relationship between central adiposity and immune and metabolic profile in postmenopausal women. Materials and methods Cross-sectional study comprising 49 postmenopausal women (aged 59.26 ± 8.32 years) without regular physical exercise practice. Body composition was measured by dual-energy X-ray absorptiometry. Fasting blood samples were collected for assessment of nonesterified fatty acids, tumor necrosis factor-α (TNF-α), interleukin-6 (IL-6), adiponectin, insulin and estimation of insulin resistance (HOMA-IR). Physical activity level was assessed with an accelerometer (Actigraph GTX3x) and reported as a percentage of time spent in sedentary behavior and MVPA. All analyses were performed using the software SPSS 17.0, with a significance level set at 5%. Results Sedentary women had a positive relationship between trunk fat and IL-6 (rho = 0.471; p = 0.020), and trunk fat and HOMA-IR (rho = 0.418; p = 0.042). Adiponectin and fat mass (%) were only positively correlated in physically active women (rho = 0.441; p = 0.027). Physically active women with normal trunk fat values presented a 14.7% lower chance of having increased HOMA-IR levels (β [95%CI] = 0.147 [0.027; 0.811]). Conclusions The practice of sufficient levels of MVPA was a protective factor against immunometabolic disorders in postmenopausal women.


Sujet(s)
Humains , Femelle , Adulte d'âge moyen , Sujet âgé , Exercice physique , Interleukine-6/sang , Post-ménopause/métabolisme , Obésité abdominale/sang , Composition corporelle , Insulinorésistance , Absorptiométrie photonique/instrumentation , Études transversales , Jeûne/sang , Post-ménopause/sang , Graisse abdominale/métabolisme , Adiponectine/sang , Adiposité , Acides gras/sang , Mode de vie sédentaire , Facteurs de protection , Hormone folliculostimulante/sang
5.
Braspen J ; 32(2): 119-124, abr.-jun. 2017.
Article de Portugais | LILACS | ID: biblio-848143

RÉSUMÉ

Introdução: O tipo de atividade física (AF) pode influenciar a relação entre esta e a densidade mineral óssea (DMO). Desta forma, o objetivo do presente estudo é avaliar a relação entre diferentes tipos de AF e DMO em adultos. Método: Estudo transversal realizado com amostra de conveniência (n=208 indivíduos de 20 a 59 anos) de Pelotas, RS. A DMO (g/cm2) foi avaliada por absorciometria de raios-X de dupla energia (DXA) e a prática de caminhada e AF de intensidades moderada e vigorosa no lazer foram avaliadas por meio da respectiva seção da versão longa do Questionário Internacional de Atividade Física (IPAQ). A associação entre a DMO e os diferentes tipos de AF foi avaliada por regressão linear. Resultados: Em torno de 67% dos participantes atendiam à recomendação de ≥150 min/sem de AF. Não houve diferença estatisticamente significativa nas medidas da DMO entre indivíduos com maior ou menor tempo semanal em prática de caminhada, AF de intensidade moderada e vigorosa, isoladamente. Porém, foi observado um aumento, com margem inferior do intervalo de confiança no limite da significância, na DMO de indivíduos do segundo tercil de tempo gasto em AF total ­ 160-300 min/sem (ß=0,025 IC95%=0,001; 0,049), quando comparados ao grupo menos ativo. Conclusão: O estudo não encontrou associação entre DMO e a prática de caminhada e AF de intensidade moderada e vigorosa, podendo haver uma relação com o total acumulado de AF por semana, entre indivíduos que atendem à recomendação de AF, mas não são altamente ativos.(AU)


Introduction: Type of physical activity (PA) can influence the relationship between it and bone mineral density (BMD). Thus, the aim of the current study is evaluate the relationship between different types of PA and BMD in adults. Methods: Cross-sectional study using a convenience sample (n=208 individuals from 20 to 59 years old) in Pelotas, RS. BMD (g/cm2) was measured by dual energy X-ray absorptiometry (DXA) and time spent in walking and moderate and vigorous PA during the leisure-time was evaluated by the International Physical Activity Questionnaire in the long version. Association between BMD and types of PA was evaluated by linear regression analyses. Results: About 67% out of the subjects reached the recommendation of ≥150 min/week of PA during the leisure-time. There was no statistically significant difference in the BMD among individuals with higher or lower weekly time spent in walking, moderate or vigorous PA. However, a slightly difference was observed in BMD from subjects in the second tertile of time spent in any activity ­ 160-300 min/week (ß=0.025 IC95%=0.001; 0.049), in comparison to individuals in the first tertile of PA. Conclusion: There was no statistical association of walking, moderate and vigorous PA alone with BMD. It is possible a relationship between the total amount weekly spent in any PA in individuals who reached the PA recommendation but were not highly active.(AU)


Sujet(s)
Humains , Adulte , Adulte d'âge moyen , Composition corporelle , Densité osseuse , Activité motrice , Absorptiométrie photonique/instrumentation , Études transversales/instrumentation , Marche à pied
6.
J. pediatr. (Rio J.) ; J. pediatr. (Rio J.);89(6): 567-574, nov.-dez. 2013. tab
Article de Portugais | LILACS | ID: lil-697131

RÉSUMÉ

OBJETIVO: determinar a capacidade preditiva de quatro equipamentos distintos de bioimpedância elétrica (BIA) na avaliação de adolescentes, com e sem a realização de protocolo. MÉTODOS: estudo transversal realizado com 215 adolescentes de 10 a 14 anos, de ambos os sexos, avaliados através da antropometria e da composição corporal pelo DEXA e por quatro equipamentos distintos de BIA, com e sem protocolo. Foram utilizados os testes estatísticos: Kolmogorov-Smirnov, do Qui-quadrado, t-Student ou Mann-Whitney, Kruskal-Wallis, Wilcoxon e Índice Kappa. Foram construídas curvas ROC e calculados os valores de sensibilidade, especificidade e preditivos positivo e negativo. RESULTADOS: dos adolescentes, 44,2% apresentaram excesso de gordura corporal. A BIA tetrapolar, equipada com oito eletrodos táteis, demonstrou-se mais sensível e com resultados mais próximos ao DEXA (AUC = 0,964 com protocolo e AUC = 0,973 sem protocolo, p < 0,001), apresentando, também, maior concordância (k = 0,67 com protocolo, e k = 0,63 sem protocolo, p < 0,001). A avaliação sem protocolo foi semelhante ao DEXA na maioria das situações investigadas (p > 0,05). CONCLUSÃO: a BIA é um instrumento capaz de predizer distrofias relacionadas à gordura corporal de adolescentes. Na impossibilidade de realização do protocolo, seus resultados podem ser úteis em estudos populacionais.


OBJECTIVE: this study was performed to determine the predictive capacity of four different bioelectrical impedance analysis (BIA) devices in the assessment of adolescents, with and without a protocol. METHODS: a cross-sectional study was performed with 215 adolescents aged 10 to 14 years, of both genders, evaluated through anthropometry and body composition by dual energy X-ray absorptiometry (DXA) and by four different BIA devices, with and without a protocol. The following tests were used: Kolmogorov-Smirnov's, chi-squared, Student's t or Mann-Whitney's, Kruskal-Wallis's, Wilcoxon's, and kappa index. The ROC curves were constructed and the sensitivity, specificity, and positive and negative predictive values were calculated. RESULTS: of the 215 adolescents, 44.2% had excessive body fat. The tetrapolar BIA device equipped with eight tactile electrodes showed more sensitivity and results that were closer to those obtained by DXA (area under the ROC curve [AUC] = 0.964 with protocol and AUC = 0.973 without protocol, p < 0.001), as well as greater agreement (k = 0.67 with protocol and k = 0.63 without protocol, p < 0.001). The evaluation without protocol was similar to that by DXA in most investigated situations (p > 0.05). CONCLUSION: BIA is capable of predicting alterations in adolescents' body composition. When it is impossible to perform the assessment with a protocol, its results may be useful in population studies.


Sujet(s)
Adolescent , Enfant , Femelle , Humains , Mâle , Absorptiométrie photonique/instrumentation , Adiposité/physiologie , Composition corporelle/physiologie , Protocoles cliniques/normes , Impédance électrique , Indice de masse corporelle , Loi du khi-deux , Études transversales , Valeur prédictive des tests , Statistique non paramétrique
7.
J Pediatr (Rio J) ; 89(6): 567-74, 2013.
Article de Anglais | MEDLINE | ID: mdl-24035874

RÉSUMÉ

OBJECTIVE: this study was performed to determine the predictive capacity of four different bioelectrical impedance analysis (BIA) devices in the assessment of adolescents, with and without a protocol. METHODS: a cross-sectional study was performed with 215 adolescents aged 10 to 14 years, of both genders, evaluated through anthropometry and body composition by dual energy X-ray absorptiometry (DXA) and by four different BIA devices, with and without a protocol. The following tests were used: Kolmogorov-Smirnov's, chi-squared, Student's t or Mann-Whitney's, Kruskal-Wallis's, Wilcoxon's, and kappa index. The ROC curves were constructed and the sensitivity, specificity, and positive and negative predictive values were calculated. RESULTS: of the 215 adolescents, 44.2% had excessive body fat. The tetrapolar BIA device equipped with eight tactile electrodes showed more sensitivity and results that were closer to those obtained by DXA (area under the ROC curve [AUC] = 0.964 with protocol and AUC = 0.973 without protocol, p < 0.001), as well as greater agreement (k = 0.67 with protocol and k = 0.63 without protocol, p < 0.001). The evaluation without protocol was similar to that by DXA in most investigated situations (p > 0.05). CONCLUSION: BIA is capable of predicting alterations in adolescents' body composition. When it is impossible to perform the assessment with a protocol, its results may be useful in population studies.


Sujet(s)
Absorptiométrie photonique/instrumentation , Adiposité/physiologie , Composition corporelle/physiologie , Protocoles cliniques/normes , Impédance électrique , Adolescent , Indice de masse corporelle , Loi du khi-deux , Enfant , Études transversales , Femelle , Humains , Mâle , Valeur prédictive des tests , Statistique non paramétrique
8.
Rev Sci Instrum ; 82(12): 125105, 2011 Dec.
Article de Anglais | MEDLINE | ID: mdl-22225247

RÉSUMÉ

Bones are the support of the body. They are composed of many inorganic compounds and other organic materials that all together can be used to determine the mineral density of the bones. The bone mineral density is a measure index that is widely used as an indicator of the health of the bone. A typical manner to evaluate the quality of the bone is a densitometry study; a dual x-ray absorptiometry system based study that has been widely used to assess the mineral density of some animals' bones. However, despite the success stories of utilizing these systems in many different applications, it is a very expensive method that requires frequent calibration processes to work properly. Moreover, its usage in small species applications (e.g., rodents) has not been quite demonstrated yet. Following this argument, it is suggested that there is a need for an instrument that would perform such a task in a more reliable and economical manner. Therefore, in this paper we explore the possibility to develop a new, affordable, and reliable single x-ray absorptiometry system. The method consists of utilizing a single x-ray source, an x-ray image sensor, and a computer platform that all together, as a whole, will allow us to calculate the mineral density of the bone. Utilizing an x-ray transmission theory modified through a version of the Lambert-Beer law equation, a law that expresses the relationship among the energy absorbed, the thickness, and the absorption coefficient of the sample at the x-rays wavelength to calculate the mineral density of the bone can be advantageous. Having determined the parameter equation that defines the ratio of the pixels in radiographies and the bone mineral density [measured in mass per unit of area (g/cm(2))], we demonstrated the utility of our novel methodology by calculating the mineral density of Wistar rats' femur bones.


Sujet(s)
Absorptiométrie photonique/instrumentation , Densité osseuse , Animaux , Bovins , Femelle , Fémur/imagerie diagnostique , Fémur/physiologie , Radiographie , Rats , Rat Wistar , Facteurs temps
9.
J Appl Oral Sci ; 18(4): 390-6, 2010.
Article de Anglais | MEDLINE | ID: mdl-20835575

RÉSUMÉ

OBJECTIVES: To produce a copper (Cu) stepwedge with aluminum (Al) equivalent mean gray values (MGV). MATERIAL AND METHODS: The thicknesses of Cu steps that were equivalent to those of the Al were formulated using the X-ray attenuation properties of the materials. The Al and fabricated Cu stepwedges were radiographed, but the MGVs of the Cu stepwedge were mismatching to those of the Al. Using a mathematical function to adjust the pixel MGV of Cu stepwedge to those of the Al, new Cu stepwedges were created. In vitro iterations were performed until best approximation to Al was reached. RESULTS: The MGV of the Cu stepwedges fabricated by formularization were different than those of Al (p=0.001). Iteration method led to MGV similar to those of the Al stepwedge (p=0.207). CONCLUSIONS: Construction of a Cu stepwedge according to the basic rules of radiophysic failed to result in a stepwedge with similar radiodensity values to those of Al stepwedge. Further studies may use the formularization method only for prototype Cu wedge production, but consecutive iterations shall be compassed to obtain the best approximation to Al MGV.


Sujet(s)
Absorptiométrie photonique/instrumentation , Aluminium/composition chimique , Cuivre/composition chimique , Radiographie panoramique/instrumentation , Algorithmes , Humains , Traitement d'image par ordinateur/méthodes , Phénomènes optiques , Dose de rayonnement , Radiographie panoramique/normes , Normes de référence , Spectrophotométrie atomique , Propriétés de surface , Film radiographique/normes
10.
J. appl. oral sci ; J. appl. oral sci;18(4): 390-396, July-Aug. 2010. ilus, graf, tab
Article de Anglais | LILACS | ID: lil-557110

RÉSUMÉ

OBJECTIVES: To produce a copper (Cu) stepwedge with aluminum (Al) equivalent mean gray values (MGV). MATERIAL AND METHODS: The thicknesses of Cu steps that were equivalent to those of the Al were formulated using the X-ray attenuation properties of the materials. The Al and fabricated Cu stepwedges were radiographed, but the MGVs of the Cu stepwedge were mismatching to those of the Al. Using a mathematical function to adjust the pixel MGV of Cu stepwedge to those of the Al, new Cu stepwedges were created. In vitro iterations were performed until best approximation to Al was reached. RESULTS: The MGV of the Cu stepwedges fabricated by formularization were different than those of Al (p=0.001). Iteration method led to MGV similar to those of the Al stepwedge (p=0.207). CONCLUSIONS: Construction of a Cu stepwedge according to the basic rules of radiophysic failed to result in a stepwedge with similar radiodensity values to those of Al stepwedge. Further studies may use the formularization method only for prototype Cu wedge production, but consecutive iterations shall be compassed to obtain the best approximation to Al MGV.


Sujet(s)
Humains , Absorptiométrie photonique/instrumentation , Aluminium/composition chimique , Cuivre/composition chimique , Radiographie panoramique/instrumentation , Algorithmes , Traitement d'image par ordinateur/méthodes , Phénomènes optiques , Dose de rayonnement , Normes de référence , Radiographie panoramique/normes , Spectrophotométrie atomique , Propriétés de surface , Film radiographique/normes
11.
Phys Med Biol ; 51(9): 2307-20, 2006 May 07.
Article de Anglais | MEDLINE | ID: mdl-16625044

RÉSUMÉ

Radiological contrast-to-noise ratio (CNR) is evaluated in subtracted images of microcalcifications in breast tissue. CNR is calculated for dual-kVp subtraction combining beams available in a Senographe 2000D, assuming single breast compression. Spectra were obtained from Boone et al (1997 Med. Phys. 24 1863-73), and the study was limited to lowest 25 kV Mo/Mo and highest 40 kV Rh/Rh beams, for 2.58 x 10(-4) C kg(-1) (1R) total exposure. For a standard case combining 25 kVp Mo/Mo and 40 kVp Rh/Rh beams, predicted maximum CNR for 300 microm calcification in 5 cm thick, 50% glandular, breast is about 1.2, below Rose's criterion for visualization. Total mean glandular doses are about 2.5 cGy for a standard case. The effect that input factors might have on predictions has been evaluated. Choice between alternative spectra can affect CNR by 50%. Assumed calcification composition leads to differences of 67% in calculated CNR, and assumed breast tissue composition can alter CNR by 45%; these results are weakly dependent on calcification or breast thickness, or on the assumed fraction of glandular tissue. CNR values are related to detected spectra effective energy. Calculations predict that above 37 kVp Mo/Mo beams are more energetic than Rh/Rh at the same kVp, due to beam hardening.


Sujet(s)
Absorptiométrie photonique/instrumentation , Algorithmes , Mammographie/instrumentation , Amélioration d'image radiographique/instrumentation , Amélioration d'image radiographique/méthodes , Interprétation d'images radiographiques assistée par ordinateur/méthodes , Absorptiométrie photonique/méthodes , Conception d'appareillage , Analyse de panne d'appareillage , Humains , Mammographie/méthodes , Reproductibilité des résultats , Sensibilité et spécificité
12.
J Pediatr ; 143(1): 81-8, 2003 Jul.
Article de Anglais | MEDLINE | ID: mdl-12915829

RÉSUMÉ

OBJECTIVE: Most studies that use total body dual energy x-ray absorptiometry (DEXA) in children rely on areal bone mineral density (BMD=bone mineral content [BMC]/bone area [BA]) and compare the output with age- and sex-specific normative data. Because this approach is prone to size-related misinterpretation, this study focuses on the interrelations among BMC, body size (height), and lean tissue mass (LTM). STUDY DESIGN: This cross-sectional study presents normative total body LTM data in relation to height and BMC for 459 healthy white subjects (249 female), 3 to 30 years of age. Guidelines for DEXA interpretation in children are provided and illustrated for patients with growth hormone deficiency (n=5) and anorexia nervosa (n=5). RESULTS: LTM/height tended to be greater in male than in girls. The BMC/LTM ratio was greater in female than in boys (P<.001), even after adjustment for age and height. Sex-specific reference curves were created for LTM/height, the BMC/LTM ratio, BA/height, and BMC/BA. CONCLUSIONS: We recommend that total body DEXA in children should be interpreted in 4 steps: (1) BMD or BMC/age, (2) height/age, (3) LTM/height, and (4) BMC/LTM ratio for height. This allows differentiation of the origin of a low BMD or BMC/age, for example, short stature and primary, secondary, and mixed bone defects.


Sujet(s)
Absorptiométrie photonique/instrumentation , Troubles de la croissance/diagnostic , Interprétation d'images assistée par ordinateur/instrumentation , Adolescent , Adulte , Répartition par âge , Taille , Indice de masse corporelle , Densité osseuse/physiologie , Enfant , Enfant d'âge préscolaire , Études transversales , Femelle , Troubles de la croissance/épidémiologie , Humains , Mâle , Répartition par sexe
13.
Phys Med Biol ; 48(23): 3851-63, 2003 Dec 07.
Article de Anglais | MEDLINE | ID: mdl-14703162

RÉSUMÉ

The application of the dual photon absorptiometry (DPA) technique, using gadolinium-153 as the photon source, to evaluate the bone mineral density (BMD) of the third metacarpal bone of horses is presented. The radiation detector was implemented with a NaI(TI) scintillator coupled to a 14 stage photomultiplier. A modular mechanical system allows the position of the prototype to be adjusted in relation to the animal. A moveable carrier makes it possible to scan the third metacarpal with a velocity adjustable between 1 and 12 mm s(-1), in steps of 1 mm s(-1), for a total distance of 250 mm. The prototype was evaluated with a phantom of the third metacarpal bone made of perspex and aluminium, and in vitro with a transverse slice of the third metacarpal bone of a horse. The tests showed that the prototype has an accuracy and precision of, approximately, 10% and 6%, respectively, for a 6 s acquisition time. Preliminary studies carried out in three foals from birth to one year of age indicated that the prototype is well suited to in vivo and in situ analysis of the BMD of the third metacarpal bones of horses, making it possible to evaluate the changes of BMD levels on a monthly basis. Also, results indicated an exponential behaviour of the BMD curve during the first year of life of the studied horses.


Sujet(s)
Absorptiométrie photonique/instrumentation , Absorptiométrie photonique/médecine vétérinaire , Densité osseuse/physiologie , Gadolinium , Equus caballus/physiologie , Métacarpe/imagerie diagnostique , Métacarpe/physiologie , Absorptiométrie photonique/méthodes , Vieillissement/physiologie , Animaux , Conception d'appareillage , Analyse de panne d'appareillage/méthodes , Études de faisabilité , Fantômes en imagerie , Projets pilotes , Radio-isotopes , Scintigraphie , Reproductibilité des résultats , Sensibilité et spécificité
14.
Bauru; s.n; 1999. 88 p. ilus, tab, graf.
Thèse de Portugais | LILACS, BBO - Ondontologie | ID: lil-256160

RÉSUMÉ

O presente trabalho teve o objetivo de analisar a utilizaçäo das Densidade Radiográfica (DR), e Densidades Radiográfica invertidas (DRi), como substituto das Densidades Oticas (DO). As diferentes medidas foram executadas a partir da utilizaçäo de tiras de filmes extra-bucais XK-1, que foram expostas no sensitômetro MRA com 0,5 segundo. As tiras foram processadas em soluçöes processadoras RP X-OMAT da Kodak, na processadora automática DU PONT T-4, nas temperaturas de 27ºC, 29ºC, 31ºC e 34ºC. Para se avaliar a DO utilizou-se o fotodensitômetro MRA e para a avaliaçäo das Densidades Radiográficas escaneou-se as tiras de filmes com o escaner Scanjet da HP 4C/T e utilizou-se o software Digora for Windows 1.51 que forneceu os dados que puderam ser comparados para avaliaçäo da soluçäo de processamento radiográfico quanto a atividade, uso e degradaçäo da mesma em diferentes processamentos. Os resultados mostraram que a DO teve maior número de processamentos superiores a média nas temperaturas de 31ºC e 34ºC, mostrando que os processamentos foram mais eficientes. A avaliaçäo da DR e DRi revelou que em todas as temperaturas os processamentos apresentaram um equilíbrio de resultados e que foram menos discrepantes na variaçäo dos resultados...


Sujet(s)
Absorptiométrie photonique , Absorptiométrie photonique/instrumentation , Diagnostic buccal/méthodes , Radiologie , Radiologie/instrumentation , Technologie radiologique/classification , Technologie radiologique/instrumentation , Technologie radiologique/méthodes , Film radiographique/statistiques et données numériques
15.
Bauru; s.n; 1999. 113 p. ilus, tab, graf.
Thèse de Portugais | LILACS, BBO - Ondontologie | ID: lil-250831

RÉSUMÉ

Este trabalho teve o objetivo de analisar a utilizaçäo das Densidades Radiográfica (D.R) e Radiográfica invertida (D.Ri), obtidas pelo uso do "software"de imagem Adobe Photoshop 4.0, para substituir a Densidade Óptica (D.O) na avaliaçäo dos filmes e soluçöes de processamento. Utilizamos tiras de filmes extrabucais TMS-1 que após serem expostas no sensitômetro MRA por 0,5 segundo, foram processadas na soluçäo RP X-OMAT da Kodak na processadora automática CRONEX T4 da DU PONT, nas temperaturas de 27ºC, 29ºC, 31ºC e 34ºC. Utilizamos o fotodensitômetro M R A para avaliar a Densidade Óptica (D.O). Para analisar a Densidade Rdaiográfica (D.R) e Densidade Radiográfica invertida (D.Ri), as tiras de filmes foram escaneadas (Scanjet HP 4C/T), e utilizamos o "software" Adobe Photoshop 4.0, para a obtençäo dos resultados (D.R e D.Ri). Esses dados serviram para avaliar a soluçäo de processamento radiográfica, quanto a sua atividade, degradaçäo e uso em diferentes temperaturas. A análise dos resultados demonstrou que os processamentos foram mais eficientes nas temperaturas de 31º e 34ºC. Em relaçäo à Densidade Óptica quando comparada à Densidade Radiográfica e Densidade Radiográfica invertida, observamos que estas demonstraram maior equilíbrio e resultados menos discrepantes. A análise estatística dos resultados obtidos pela correlaçäo de Pearson, demonstrou em relaçäo à Densidade Óptica, alta correlaçäo em todas as temperaturas avaliadas e uma correlaçäo ainda maior nas temperaturas de 31ºC e 34ºC quando comparamos com a Densidade Radiográfica e Densidade Radiográfica invertida...


Sujet(s)
Absorptiométrie photonique , Absorptiométrie photonique/classification , Absorptiométrie photonique/instrumentation , Film radiographique/classification , Film radiographique/normes , Radiographie numérisée dentaire/classification , Radiographie numérisée dentaire/instrumentation , Radiographie numérisée dentaire/méthodes , Interprétation d'images radiographiques assistée par ordinateur , Validation de logiciel , Logiciel/classification
16.
Rev Med Chil ; 126(1): 56-62, 1998 Jan.
Article de Espagnol | MEDLINE | ID: mdl-9629755

RÉSUMÉ

Dual energy x-ray absorptiometry (DEXA) is one of the most widely used methods for bone mineral density (BMD), total body mass (TBM), total body fat (TBF), percentage of total body fat (%TBF) and total body fat-free mass (TBFFM) measurements. We investigated the in vitro and in vivo accuracy and precision of DEXA in repeated measurements of a lumbar spine phantom and in 30 healthy volunteers. Based on precision, the minimal significant variability (MSV) at 95% confidence level between 2 measurements of the same object or subject was calculated. In vitro accuracy and MSV were 99.8 and 0.9% respectively. In vivo indexes were 99.4 and 0.9% for whole-body BMD, 98.6 and 2% for lumbar spine BMD, 96.6 and 4.8% for femoral neck BMD, 98 and 2.8% for major trochanter BMD, 96 and 5.7% for Ward's triangle BMD, 99.5 and 0.7% for TBM, 98 and 2.9% for TBF, 97.9 and 3% for %TBF and 99 and 1.4% for TBFFM. Our findings indicate that DEXA is a very reliable instrument and in order to be 95% confident of a real change between 2 scans a difference of at least the calculated MSV must be measured.


Sujet(s)
Absorptiométrie photonique/normes , Densité osseuse , Contrôle de qualité , Absorptiométrie photonique/instrumentation , Tissu adipeux/imagerie diagnostique , Adulte , Indice de masse corporelle , Intervalles de confiance , Femelle , Humains , Mâle , Adulte d'âge moyen , Fantômes en imagerie , Reproductibilité des résultats , Rachis/imagerie diagnostique
17.
Rev. méd. Chile ; 126(1): 56-62, ene. 1998. tab
Article de Espagnol | LILACS | ID: lil-210410

RÉSUMÉ

Dual energy x-ray absorptiometry (DEXA) is one of the most widely used methods for bone mineral density (BMD), total body mass (TBM), total body fat (TBF), percentage of total body ft (TBF) and total body fat-free mass (TBFFM) measurements. We investigated the in vitro and vivo accuracy and precision of DEXA in repeated measurements of a lumbar espine phantom and in 30 healthy volunteers. Based on precision, the minimal significant variability (MSV) at 95 por ciento confidence level between 2 measurement of the same object or subject was calculated. In vitro accuracy and MSV were 99.8 and 0.9 por ciento respectively. In vivo indexes were 99.4 and 0.9 percent for whole-body BMD. 98.6 and 2 percent for lumbar spine BMD, 96.6 and 4.8 percent for femoral neck BMD, 98 and 2.8 percent for major trochanter BMD, 96 and 5,7 percent for Ward's triangle BMD, 99.5 and 0.7 percent for TBM, 98 and 2.9 percent for TBF, 97.9 and 3 percent for TBF and 99 and 1.4 percent for TBFFM. Our fIndings indicate that DEXA is a very reliable instrument and in order to be 95 percent confident of a real change between 2 scans a difference of at least the calculated MSV must be measured


Sujet(s)
Humains , Femelle , Mâle , Adulte , Adulte d'âge moyen , Ostéoporose/diagnostic , Absorptiométrie photonique , Densité osseuse/physiologie , Absorptiométrie photonique/instrumentation , Anthropométrie , Composition corporelle/physiologie
18.
J Pediatr ; 127(5): 819-22, 1995 Nov.
Article de Anglais | MEDLINE | ID: mdl-7472845

RÉSUMÉ

Treatment of adults with gonadotropin releasing hormone analogs has resulted in rapid loss in bone mineral density (BMD). We measured lumbar and femoral neck BMD by dual-energy x-ray absorptiometry during 2 years of depot leuprolide therapy in 13 girls (mean age, 7.5 years; mean bone age, 10.9 years). At baseline, BMD was elevated for age and concordant with the advanced skeletal age. During therapy with gonadotropin releasing hormone analog, BMD values increased and BMD standard deviation scores for age and skeletal age did not change.


Sujet(s)
Densité osseuse/effets des médicaments et des substances chimiques , Puberté précoce/traitement médicamenteux , Absorptiométrie photonique/instrumentation , Absorptiométrie photonique/méthodes , Absorptiométrie photonique/statistiques et données numériques , Détermination de l'âge à partir du squelette , Enfant , Enfant d'âge préscolaire , Préparations à action retardée , Femelle , Humains , Leuprolide/administration et posologie , Leuprolide/effets indésirables , Études longitudinales , Puberté précoce/physiopathologie , Facteurs temps
19.
Calcif Tissue Int ; 57(3): 165-8, 1995 Sep.
Article de Anglais | MEDLINE | ID: mdl-8574930

RÉSUMÉ

To assess the usefulness of the measurement of the os calcis by ultrasound, a method that probably reflects bone quality as well as density, we have studied 54 women with hip fracture of the proximal femur and a control group. Ultrasound evaluation of the os calcis [broadband ultrasound attenuation (BUA), speed of the sound (SOS), and a combined index ("stiffness")], and bone mineral density (BMD) determination over the proximal femur by dual X-ray absorptiometry (DXA) were performed. Weight, BMD, and ultrasound values in the hip fracture patients were significantly lower than controls (P < 0.001). The Z-scores for BUA and stiffness were not different than that for femoral neck, Ward's triangle or trochanteric BMD (between -1.7 and -1.5). The odds ratios determined by receiver-operating characteristics (ROC) analysis were greater at the femoral neck (25.1) and BUA (24.4). Intermediate values were found at stiffness (16.9), Ward's triangle (12.8), and trochanter (11.1), and lower values were obtained at SOS (4.2). In turn, patients with trochanteric hip fractures had a significantly lower femoral neck and Ward's triangle BMD, stiffness, and BUA than patients with cervical hip fractures. Comparing a subgroup of 30 women with hip fractures without vertebral fractures with an age-matched group of 87 women with osteoporotic vertebral fractures, both groups were of similar weight and BMD but all ultrasound values were significantly lower in the hip fractures compared with vertebral fracture patients (P < 0.05 - P < 0.01).(ABSTRACT TRUNCATED AT 250 WORDS)


Sujet(s)
Absorptiométrie photonique/méthodes , Fractures de la hanche/imagerie diagnostique , Absorptiométrie photonique/instrumentation , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Vieillissement , Poids , Densité osseuse , Femelle , Humains , Adulte d'âge moyen , Sensibilité et spécificité , Échographie