Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 1.440
Filtrer
1.
Sci Data ; 11(1): 806, 2024 Jul 20.
Article de Anglais | MEDLINE | ID: mdl-39033239

RÉSUMÉ

Lower limb amputation is a medical intervention which causes motor disability and may compromise quality of life. Several factors determine patients' health outcomes, including an appropriate prosthetic provision and an effective rehabilitation program, necessitating a thorough quantitative observation through different data sources. In this context, the role of interoperability becomes essential, facilitating the reuse of real-world data through the provision of structured and easily accessible databases. This study introduces a comprehensive 10-year dataset encompassing clinical features, mobility measurements, and prosthetic knees of 1006 trans-femoral amputees during 1962 hospital stays for rehabilitation. The dataset is made available in both comma-separated values (CSV) format and HL7 Fast Healthcare Interoperability Resources (FHIR)-based representation, ensuring broad utility and compatibility for researchers and healthcare practitioners. This initiative contributes to advancing community understanding of post-amputation rehabilitation and underscores the significance of interoperability in promoting seamless data sharing for meaningful insights into healthcare outcomes.


Sujet(s)
Amputation chirurgicale , Humains , Amputation chirurgicale/rééducation et réadaptation , Membres artificiels , Amputés/rééducation et réadaptation , Fémur/chirurgie , Collecte de données
2.
Article de Anglais | MEDLINE | ID: mdl-38980789

RÉSUMÉ

Transfemoral amputation is a debilitating condition that leads to long-term mobility restriction and secondary disorders that negatively affect the quality of life of millions of individuals worldwide. Currently available prostheses are not able to restore energetically efficient and functional gait, thus, recently, the alternative strategy to inject energy at the residual hip has been proposed to compensate for the lack of energy of the missing leg. Here, we show that a portable and powered hip exoskeleton assisting both the residual and intact limb induced a reduction of walking energy expenditure in four individuals with above-knee amputation. The reduction of the energy expenditure, quantified using the Physiological Cost Index, was in the range [-10, -17]% for all study participants compared to walking without assistance, and between [-2, -24]% in three out of four study participants compared to walking without the device. Additionally, all study participants were able to walk comfortably and confidently with the hip exoskeleton overground at both their self-selected comfortable and fast speed without any observable alterations in gait stability. The study findings confirm that injecting energy at the hip level is a promising approach for individuals with above-knee amputation. By reducing the energy expenditure of walking and facilitating gait, a hip exoskeleton may extend mobility and improve locomotor training of individuals with above-knee amputation, with several positive implications for their quality of life.


Sujet(s)
Amputation chirurgicale , Amputés , Membres artificiels , Métabolisme énergétique , Dispositif d'exosquelette , Hanche , Marche à pied , Humains , Marche à pied/physiologie , Mâle , Adulte , Amputation chirurgicale/rééducation et réadaptation , Amputés/rééducation et réadaptation , Adulte d'âge moyen , Démarche/physiologie , Femelle , Phénomènes biomécaniques , Conception de prothèse , Genou
3.
PLoS One ; 19(7): e0307523, 2024.
Article de Anglais | MEDLINE | ID: mdl-39042623

RÉSUMÉ

BACKGROUND: Little is known about which outcome domains characterise meaningful recovery following prosthetic rehabilitation and should be measured. Our previous qualitative work developed a conceptual model of outcome domains which are meaningful to patients. This qualitative synthesis aims to develop that model by exploring views and experiences of recovery captured in the limb loss literature, and use these to produce a second iteration of the model describing outcome domains of importance following prosthetic rehabilitation from the patient's perspective. METHODS: Systematic searches were conducted using CINAHL, Psychinfo and Web of Science from 2011 to early 2023. Studies with a qualitative design focusing on views and experiences of lower limb prosthetic users were eligible for inclusion. Quality was assessed using the CASP tool. 'Best Fit' framework synthesis was used to synthesise the evidence and develop the conceptual model. RESULTS: 40 studies were included, describing the experiences of 539 participants. Data supported the pre-existing conceptual model and led to development of four of the five domains. The newly named ECLIPSE model describes meaningful outcome domains as 1) Being able to participate in important activities and roles, 2) Participating in the way I want to, 3) My prosthesis works for me, 4) If I am in pain, I can manage it, and 5) I am able to accept my new normal. Studies came from 15 countries showing good coverage of high-income settings. Few participants from low-and-middle-income countries were included, it is unclear if the ECLIPSE model describes outcome domains of importance in these settings. CONCLUSIONS: This synthesis provides a rigorous foundation for understanding outcome domains of importance following lower limb prosthetic rehabilitation from the patient's perspective. The ECLIPSE model is an accessible representation of recovery which could direct rehabilitation programmes, as well as inform the evaluation of prosthetic care through the selection of outcome measures.


Sujet(s)
Amputation chirurgicale , Membres artificiels , Membre inférieur , Humains , Amputation chirurgicale/rééducation et réadaptation , Membre inférieur/chirurgie , Amputés/rééducation et réadaptation , Modèles théoriques
4.
Article de Anglais | MEDLINE | ID: mdl-39018213

RÉSUMÉ

Prosthetic hands have significant potential to restore the manipulative capabilities and self-confidence of amputees and enhance their quality of life. However, incompatibility between prosthetic devices and residual limbs can lead to secondary injuries such as skin pressure ulcers and restricted joint motion, contributing to a high prosthesis abandonment rate. To address these challenges, this study introduces a data-driven design framework (D3Frame) utilizing a multi-index optimization method. By incorporating motion/ pressure data, as well as clinical criteria such as pain threshold/ tolerance, from various anatomical sites on the residual limbs of amputees, this framework aims to optimize the structural design of the prosthetic socket, including the Antecubital Channel (AC), Lateral Epicondylar Region Contour (LC), Medial Epicondylar Region Contour (MC), Olecranon Region Contour (OC), Lateral Flexor/ Extensor Region (LR), and Medial Flexor/ Extensor Region (MR). Experiments on five forearm amputees verified the improved adaptability of the optimized socket compared to traditional sockets under three load conditions. The experimental results revealed a modest score enhancement on standard clinical scales and reduced muscle fatigue levels. Specifically, the percent effort of muscles and slope value of mean/ median frequency decreased by 19%, 70%, and 99% on average, respectively, and the average values of mean/ median frequency in the motion cycle both increased by approximately 5%. The proposed D3Frame in this study was applied to optimize the structural aspects of designated regions of the prosthetic socket, offering the potential to aid prosthetists in prosthesis design and, consequently, augmenting the adaptability of prosthetic devices.


Sujet(s)
Amputés , Membres artificiels , Main , Conception de prothèse , Humains , Amputés/rééducation et réadaptation , Mâle , Adulte , Algorithmes , Adulte d'âge moyen , Moignons d'amputation/physiopathologie , Femelle
5.
Sci Rep ; 14(1): 16521, 2024 07 17.
Article de Anglais | MEDLINE | ID: mdl-39019986

RÉSUMÉ

Ankle push-off power plays an important role in healthy walking, contributing to center-of-mass acceleration, swing leg dynamics, and accounting for 45% of total leg power. The majority of existing passive energy storage and return prostheses for people with below-knee (transtibial) amputation are stiffer than the biological ankle, particularly at slower walking speeds. Additionally, passive devices provide insufficient levels of energy return and push-off power, negatively impacting biomechanics of gait. Here, we present a clinical study evaluating the kinematics and kinetics of walking with a microprocessor-controlled, variable-stiffness ankle-foot prosthesis (945 g) compared to a standard low-mass passive prosthesis (Ottobock Taleo, 463 g) with 7 study participants having unilateral transtibial amputation. By modulating prosthesis stiffness under computer control across walking speeds, we demonstrate that there exists a stiffness that increases prosthetic-side energy return, peak power, and center-of-mass push-off work, and decreases contralateral limb peak ground reaction force compared to the standard passive prosthesis across all evaluated walking speeds. We demonstrate a significant increase in center-of-mass push-off work of 26.1%, 26.2%, 29.6% and 29.9% at 0.75 m/s, 1.0 m/s, 1.25 m/s, and 1.5 m/s, respectively, and a significant decrease in contralateral limb ground reaction force of 3.1%, 3.9%, and 3.2% at 1.0 m/s, 1.25 m/s, and 1.5 m/s, respectively. This study demonstrates the potential for a quasi-passive microprocessor-controlled variable-stiffness prosthesis to increase push-off power and energy return during gait at a range of walking speeds compared to a passive device of a fixed stiffness.


Sujet(s)
Membres artificiels , Conception de prothèse , Marche à pied , Humains , Phénomènes biomécaniques , Mâle , Femelle , Marche à pied/physiologie , Adulte , Adulte d'âge moyen , Vitesse de marche/physiologie , Démarche/physiologie , Amputés/rééducation et réadaptation
6.
J Neuroeng Rehabil ; 21(1): 119, 2024 Jul 13.
Article de Anglais | MEDLINE | ID: mdl-39003459

RÉSUMÉ

The ankle-foot prosthesis aims to compensate for the missing motor functions by fitting the motion characteristics of the human ankle, which contributes to enabling the lower-limb amputees to take care of themselves and improve mobility in daily life. To address the problems of poor bionic motion of the ankle-foot prosthesis and the lack of natural interaction among the patient, prosthesis, and the environment, we developed a complex reverse-rolling conjugate joint based on the human ankle-foot structure and motion characteristics, the rolling joint was used to simulate the rolling-sliding characteristics of the knee joint. Meanwhile, we established a segmental dynamics model of the prosthesis in the stance phase, and the prosthetic structure parameters were obtained with the optimal prosthetic structure dimensions and driving force. In addition, a carbon fiber energy-storage foot was designed based on the human foot profile, and the dynamic response of its elastic strain energy at different thicknesses was simulated and analyzed. Finally, we integrated a bionic ankle-foot prosthesis and experiments were conducted to verify the bionic nature of the prosthetic joint motion and the energy-storage characteristics of the carbon fiber prosthetic foot. The proposed ankle-foot prosthesis provides ambulation support to assist amputees in returning to social life normally and has the potential to help improve clinical viability to reduce medical rehabilitation costs.


Sujet(s)
Cheville , Membres artificiels , Bionique , Pied , Conception de prothèse , Humains , Cheville/physiologie , Pied/physiologie , Amputés/rééducation et réadaptation , Articulation talocrurale/physiologie , Phénomènes biomécaniques
7.
J Neuroeng Rehabil ; 21(1): 117, 2024 Jul 13.
Article de Anglais | MEDLINE | ID: mdl-39003469

RÉSUMÉ

BACKGROUND: Falls due to stumbling are prevalent for transfemoral prosthesis users and may lead to increased injury risk. This preliminary case series analyzes the transfemoral prosthesis user stumble recovery response to highlight key deficits in current commercially-available prostheses and proposes potential interventions to improve recovery outcomes. METHODS: Six transfemoral prosthesis users were perturbed on their prosthetic limb at least three times while walking on a treadmill using obstacle perturbations in early, mid and late swing. Kinematic data were collected to characterize the response, while fall rate and key kinematic recovery metrics were used to assess the quality of recovery and highlight functional deficits in current commercially-available prostheses. RESULTS: Across all participants, 13 (54%) of the 24 trials resulted in a fall (defined as > 50% body-weight support) with all but one participant (83%) falling at least once and two participants (33%) falling every time. In contrast, in a previous study of seven young, unimpaired, non-prosthesis users using the same experimental apparatus, no falls occurred across 190 trials. For the transfemoral prosthesis users, early swing had the highest rate of falling at 64%, followed by mid-swing at 57%, and then late swing at 33%. The trend in falls was mirrored by the kinematic recovery metrics (peak trunk angle, peak trunk angular velocity, forward reach of the perturbed limb, and knee angle at ground contact). In early swing all four metrics were deficient compared to non-prosthesis user controls. In mid swing, all but trunk angular velocity were deficient. In late swing only forward reach was deficient. CONCLUSION: Based on the stumble recovery responses, four potential deficiencies were identified in the response of the knee prostheses: (1) insufficient resistance to stance knee flexion upon ground contact; (2) insufficient swing extension after a perturbation; (3) difficulty initiating swing flexion following a perturbation; and (4) excessive impedance against swing flexion in early swing preventing the potential utilization of the elevating strategy. Each of these issues can potentially be addressed by mechanical or mechatronic changes to prosthetic design to improve quality of recovery and reduce the likelihood a fall.


Sujet(s)
Chutes accidentelles , Membres artificiels , Humains , Chutes accidentelles/prévention et contrôle , Membres artificiels/effets indésirables , Mâle , Femelle , Phénomènes biomécaniques , Adulte , Adulte d'âge moyen , Marche à pied/physiologie , Fémur/physiologie , Amputés/rééducation et réadaptation , Démarche/physiologie
8.
Biomed Mater Eng ; 35(4): 401-414, 2024.
Article de Anglais | MEDLINE | ID: mdl-38995767

RÉSUMÉ

BACKGROUND: The prosthetic foot is an essential component of the prosthetic limb used by people who suffer from amputation. The prosthetic foot or limb is expensive in developing countries and cannot be used by most people with special needs. OBJECTIVE: In this study, an uncomplicated prosthetic foot is designed that can be manufactured at low costs using 3D printer technology and can be provided to a wide range of amputees. The foot was designed using CAD software and analyzed using ANSES. METHODS: Carbon fiber material was chosen to be suitable for the manufacturing process using 3D printer technology. The selected material was tested in tensile and fatigue tests to determine its mechanical properties. The numerical analysis was carried out assuming the use of an artificial foot by a patient weighing 85 kg. RESULTS: The results showed that the material proposed for manufacturing has good mechanical properties for this application. The results of the engineering analysis also showed that the model has successfully passed the design process and is reliable for use by amputees. CONCLUSION: The success model designed in this study in the numerical analysis process gives reliability to the use of this design to manufacture the prosthetic foot.


Sujet(s)
Membres artificiels , Simulation numérique , Pied , Impression tridimensionnelle , Conception de prothèse , Humains , Résistance à la traction , Conception assistée par ordinateur , Amputés/rééducation et réadaptation , Fibre de carbone/composition chimique , Test de matériaux , Analyse des éléments finis , Contrainte mécanique
9.
J Neuroeng Rehabil ; 21(1): 128, 2024 Jul 31.
Article de Anglais | MEDLINE | ID: mdl-39085954

RÉSUMÉ

BACKGROUND: Systems that capture motion under laboratory conditions limit validity in real-world environments. Mobile motion capture solutions such as Inertial Measurement Units (IMUs) can progress our understanding of "real" human movement. IMU data must be validated in each application to interpret with clinical applicability; this is particularly true for diverse populations. Our IMU analysis method builds on the OpenSim IMU Inverse Kinematics toolkit integrating the Versatile Quaternion-based Filter and incorporates realistic constraints to the underlying biomechanical model. We validate our processing method against the reference standard optical motion capture in a case report with participants with transfemoral amputation fitted with a Percutaneous Osseointegrated Implant (POI) and without amputation walking over level ground. We hypothesis that by using this novel pipeline, we can validate IMU motion capture data, to a clinically acceptable degree. RESULTS: Average RMSE (across all joints) between the two systems from the participant with a unilateral transfemoral amputation (TFA) on the amputated and the intact sides were 2.35° (IQR = 1.45°) and 3.59° (IQR = 2.00°) respectively. Equivalent results in the non-amputated participant were 2.26° (IQR = 1.08°). Joint level average RMSE between the two systems from the TFA ranged from 1.66° to 3.82° and from 1.21° to 5.46° in the non-amputated participant. In plane average RMSE between the two systems from the TFA ranged from 2.17° (coronal) to 3.91° (sagittal) and from 1.96° (transverse) to 2.32° (sagittal) in the non-amputated participant. Coefficients of Multiple Correlation (CMC) results between the two systems in the TFA ranged from 0.74 to > 0.99 and from 0.72 to > 0.99 in the non-amputated participant and resulted in 'excellent' similarity in each data set average, in every plane and at all joint levels. Normalized RMSE between the two systems from the TFA ranged from 3.40% (knee level) to 54.54% (pelvis level) and from 2.18% to 36.01% in the non-amputated participant. CONCLUSIONS: We offer a modular processing pipeline that enables the addition of extra layers, facilitates changes to the underlying biomechanical model, and can accept raw IMU data from any vendor. We successfully validate the pipeline using data, for the first time, from a TFA participant using a POI and have proved our hypothesis.


Sujet(s)
Amputation chirurgicale , Membres artificiels , Humains , Phénomènes biomécaniques , Amputation chirurgicale/rééducation et réadaptation , Fémur/chirurgie , Ostéo-intégration/physiologie , Mâle , Étude de validation de principe , Amputés/rééducation et réadaptation , Marche à pied/physiologie , Adulte , Prothèse à ancrage osseux
10.
Prosthet Orthot Int ; 48(3): 337-343, 2024 Jun 01.
Article de Anglais | MEDLINE | ID: mdl-38857166

RÉSUMÉ

BACKGROUND: Hip- and pelvic-level amputations are devastating injuries that drastically alter patient function and quality of life. This study examined the experience of military beneficiaries with a hip- or pelvic-level amputation to better characterize their challenges and specific needs and to optimize treatment in the future. METHODS: We conducted a retrospective review of the Military Health System and identified 118 patients with a history of one or more amputation(s) at the hip or pelvic level between October 2001 and September 2017. Surviving participants (n = 97) were mailed a letter which explained the details of the study and requested participation in a telephonic interview. A total of six individuals (one female, five males) participated in structured interviews. RESULTS: The study group included four participants with hip disarticulations and two participants with hemipelvectomies (one internal, one external). All six participants reported significant challenges with activities related to prosthetic use, mobility, residual limb health, pain, gastrointestinal and genitourinary function, psychiatric health, and sexual function. CONCLUSIONS: These interviews highlight the unique needs of individuals with hip- and pelvic-level amputations and may improve access to higher echelons of care that would enhance the function and quality of life for these participants.


Sujet(s)
Membres artificiels , Personnel militaire , Qualité de vie , Humains , Mâle , Femelle , Études rétrospectives , Adulte , Adulte d'âge moyen , Personnel militaire/psychologie , Amputation chirurgicale/rééducation et réadaptation , Amputation chirurgicale/psychologie , Hémipelvectomie , Amputés/psychologie , Amputés/rééducation et réadaptation , États-Unis , Pelvis
11.
Sci Rep ; 14(1): 13456, 2024 06 12.
Article de Anglais | MEDLINE | ID: mdl-38862558

RÉSUMÉ

The agonist-antagonist myoneural interface (AMI) is an amputation surgery that preserves sensorimotor signaling mechanisms of the central-peripheral nervous systems. Our first neuroimaging study investigating AMI subjects conducted by Srinivasan et al. (2020) focused on task-based neural signatures, and showed evidence of proprioceptive feedback to the central nervous system. The study of resting state neural activity helps non-invasively characterize the neural patterns that prime task response. In this study on resting state functional magnetic resonance imaging in AMI subjects, we compared functional connectivity in patients with transtibial AMI (n = 12) and traditional (n = 7) amputations (TA). To test our hypothesis that we would find significant neurophysiological differences between AMI and TA subjects, we performed a whole-brain exploratory analysis to identify a seed region; namely, we conducted ANOVA, followed by t-test statistics to locate a seed in the salience network. Then, we implemented a seed-based connectivity analysis to gather cluster-level inferences contrasting our subject groups. We show evidence supporting our hypothesis that the AMI surgery induces functional network reorganization resulting in a neural configuration that significantly differs from the neural configuration after TA surgery. AMI subjects show significantly less coupling with regions functionally dedicated to selecting where to focus attention when it comes to salient stimuli. Our findings provide researchers and clinicians with a critical mechanistic understanding of the effect of AMI amputation on brain networks at rest, which has promising implications for improved neurorehabilitation and prosthetic control.


Sujet(s)
Amputation chirurgicale , Imagerie par résonance magnétique , Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Repos/physiologie , Tibia/chirurgie , Tibia/physiopathologie , Encéphale/physiopathologie , Encéphale/imagerie diagnostique , Encéphale/physiologie , Neurophysiologie/méthodes , Amputés/rééducation et réadaptation , Cartographie cérébrale/méthodes
12.
J Biomech ; 170: 112177, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38838496

RÉSUMÉ

This study investigates the differences in peak plantar pressure between the amputated and intact limbs of transfemoral amputees when walking outdoors. Ten non-amputees (aged 24.4 ± 2.0 years, 176.9 ± 2.5 cm, 72.3 ± 7.9 kg) and six transfemoral amputees (48.5 ± 6.3 years, 173.8 ± 4.2 cm, 82.0 ± 11.9 kg) participated in the study. Over approximately 1.6 km, the participants encountered various obstacles, including stairs, uneven surfaces, hills, and level ground, both indoors and outdoors. Throughout the walking session, the peak plantar pressure in both feet was monitored using wearable insole sensors. For all terrains, the percentage asymmetry was determined. Significant changes in peak plantar pressure asymmetry were found between the intact and amputated limbs, particularly when walking on level ground indoors, uneven terrains, descending stairs, and on steep slopes outdoors (all p < 0.05). These findings highlight the greater peak plantar pressure asymmetry in transfemoral amputees when walking outside. In addition, this study revealed that not all terrains contribute uniformly to this asymmetry.


Sujet(s)
Amputés , Pied , Pression , Marche à pied , Humains , Marche à pied/physiologie , Amputés/rééducation et réadaptation , Mâle , Adulte , Adulte d'âge moyen , Pied/physiologie , Femelle , Phénomènes biomécaniques , Fémur/chirurgie , Fémur/physiologie , Membres artificiels , Jeune adulte
13.
PLoS One ; 19(6): e0299155, 2024.
Article de Anglais | MEDLINE | ID: mdl-38917074

RÉSUMÉ

Factors associated with upper limb prosthesis adoption are not well understood. In this study, we explored how prosthesis usability experience relates to the extent of prosthesis adoption through the development of a structural equation model (SEM). First, items related to prosthesis usability were developed and refined using cognitive testing and pilot testing and employed in a survey of 402 prosthesis users (mean age 61.7 (sd 14.4), 77.1% Veterans). The SEM examined two unidimensional latent constructs: Prosthesis Usability Experience and Prosthesis Adoption-and each had multiple measured indicators. SEMs tested direct as well as moderating and mediating effects between the latent constructs and covariates related to demographics and prosthesis type. SEM found a significant positive association between Prosthesis Usability Experience and Extent of Prosthesis Adoption. Several covariates had direct effects on prosthesis adoption: 1) Extent of Prosthesis Adoption was lower for those with transhumeral and shoulder amputation, and higher for those with bilateral amputation, compared to the reference group with unilateral transradial amputation and 2) Myoelectric multiple degree of freedom (multi-DOF) prosthesis use was associated with lower Extent of Prosthesis Adoption, compared to body-powered prosthesis use. Myoelectric multi-DOF use also modified the effect of Prosthesis Usability Experience on Extent of Prosthesis Adoption. For those with bilateral ULA, the strength of the relationship between Prosthesis Usability Experience and Extent of Prosthesis Adoption was reduced. Findings suggest that in order to increase prosthesis adoption, prosthetics developers and rehabilitation providers should focus on implementing strategies to improve prosthesis usability experience. New Prosthesis Usability Experience measures could be used to identify persons at greater risk for poor prosthesis adoption and target interventions to increase prosthesis use.


Sujet(s)
Membres artificiels , Membre supérieur , Humains , Membres artificiels/psychologie , Mâle , Femelle , Adulte d'âge moyen , Membre supérieur/chirurgie , Membre supérieur/physiopathologie , Sujet âgé , Analyse de structure latente , Conception de prothèse , Amputation chirurgicale/rééducation et réadaptation , Amputation chirurgicale/psychologie , Amputés/psychologie , Amputés/rééducation et réadaptation , Adulte , Enquêtes et questionnaires
14.
Int J Rehabil Res ; 47(3): 158-163, 2024 Sep 01.
Article de Anglais | MEDLINE | ID: mdl-38881492

RÉSUMÉ

High-energy expenditure during walking is one of the most important limiting factors for lower limb amputees. Although several physical training methods have been proposed to reduce energy expenditure, little is known about the effects of high-intensity interval training in lower limb amputees. This study aimed to test the effects of a 6-week high-intensity interval training protocol in subjects with lower limb amputation on walking distance, physiological cost of walking, and functional mobility. A quasi-experimental pre and post-study included 13 subjects with lower limb amputation. They performed 12 sessions of a high-intensity interval training protocol with a frequency of 2 days/week for 6 weeks. Walking distance, physiological cost of walking, and functional mobility before and after the training protocol were assessed. Walking distance increased from 204.48 to 229.09 m ( P  = 0.003), physiological cost of walking decreased from 0.66 to 0.31 beats/m ( P  = 0.001), and functional mobility improved from 30.38 to 33.61 points ( P  = 0.001). High-intensity interval training improved walking distance, physiological cost of walking, and functional mobility in subjects with lower limb amputation.


Sujet(s)
Amputés , Entrainement fractionné de haute intensité , Membre inférieur , Marche à pied , Humains , Mâle , Adulte d'âge moyen , Femelle , Amputés/rééducation et réadaptation , Marche à pied/physiologie , Adulte , Membre inférieur/chirurgie , Métabolisme énergétique/physiologie , Sujet âgé , Amputation chirurgicale/rééducation et réadaptation
15.
Gait Posture ; 112: 59-66, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38744022

RÉSUMÉ

BACKGROUND: Transhumeral (TH) limb loss leads to loss of body mass and reduced shoulder range of motion. Despite most owning a prosthesis, prosthesis abandonment is common. The consequence of TH limb loss and prosthesis use and disuse during gait may be compensation in the upper body, contributing to back pain or injury. Understanding the impact of not wearing a TH prosthesis on upper body asymmetries and spatial-temporal aspects of gait will inform how TH prosthesis use and disuse affects the body. RESEARCH QUESTION: Does TH limb loss alter upper body asymmetries and spatial-temporal parameters during gait when wearing and not wearing a prosthesis compared to able-bodied controls? METHODS: Eight male TH limb loss participants and eight male control participants completed three gait trials at self-selected speeds. The TH limb loss group performed trials with and without their prosthesis. Arm swing, trunk angular displacement, trunk-pelvis moment, and spatial-temporal aspects were compared using non-parametric statistical analyses. RESULTS: Both TH walking conditions showed greater arm swing in the intact limb compared to the residual (p≤0.001), resulting in increased asymmetry compared to the control group (p≤0.001). Without the prosthesis, there was less trunk flexion and lateral flexion compared to the control group (p≤0.001). Maximum moments between the trunk and pelvis were higher in the TH group than the control group (p≤0.05). Spatial-temporal parameters of gait did not differ between the control group and either TH limb loss condition. SIGNIFICANCE: Prosthesis use affects upper body kinematics and kinetics, but does not significantly impact spatial-temporal aspects of gait, suggesting these are compensatory actions. Wearing a prosthesis helps achieve more normative upper body kinematics and kinetics than not wearing a prosthesis, which may help limit back pain. These findings emphasize the importance of encouraging at least passive use of prostheses for individuals with TH limb loss.


Sujet(s)
Membres artificiels , Démarche , Humains , Mâle , Phénomènes biomécaniques , Démarche/physiologie , Adulte , Amplitude articulaire/physiologie , Humérus/physiologie , Adulte d'âge moyen , Amputés/rééducation et réadaptation , Membre supérieur/physiologie , Études cas-témoins
16.
Article de Anglais | MEDLINE | ID: mdl-38739519

RÉSUMÉ

Intuitive regression control of prostheses relies on training algorithms to correlate biological recordings to motor intent. The quality of the training dataset is critical to run-time regression performance, but accurately labeling intended hand kinematics after hand amputation is challenging. In this study, we quantified the accuracy and precision of labeling hand kinematics using two common training paradigms: 1) mimic training, where participants mimic predetermined motions of a prosthesis, and 2) mirror training, where participants mirror their contralateral intact hand during synchronized bilateral movements. We first explored this question in healthy non-amputee individuals where the ground-truth kinematics could be readily determined using motion capture. Kinematic data showed that mimic training fails to account for biomechanical coupling and temporal changes in hand posture. Additionally, mirror training exhibited significantly higher accuracy and precision in labeling hand kinematics. These findings suggest that the mirror training approach generates a more faithful, albeit more complex, dataset. Accordingly, mirror training resulted in significantly better offline regression performance when using a large amount of training data and a non-linear neural network. Next, we explored these different training paradigms online, with a cohort of unilateral transradial amputees actively controlling a prosthesis in real-time to complete a functional task. Overall, we found that mirror training resulted in significantly faster task completion speeds and similar subjective workload. These results demonstrate that mirror training can potentially provide more dexterous control through the utilization of task-specific, user-selected training data. Consequently, these findings serve as a valuable guide for the next generation of myoelectric and neuroprostheses leveraging machine learning to provide more dexterous and intuitive control.


Sujet(s)
Algorithmes , Membres artificiels , Électromyographie , Main , Humains , Électromyographie/méthodes , Phénomènes biomécaniques , Mâle , Femelle , Adulte , Main/physiologie , Reproductibilité des résultats , Amputés/rééducation et réadaptation , , Conception de prothèse , Mouvement/physiologie , Jeune adulte , Volontaires sains , Dynamique non linéaire
17.
J Vasc Surg ; 80(2): 529-536, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38777159

RÉSUMÉ

BACKGROUND: Studies suggest that ambulation after major lower extremity amputation (LEA) is low and mortality after LEA is high. Successful prosthetic fitting after LEA has a significant quality of life benefit; however, it is unclear if there are benefits in post-LEA mortality. Our objective was to examine a contemporary cohort of patients who underwent LEA and determine if there is an association between fitting for a prosthetic and mortality. METHODS: We reviewed all patients who underwent LEA between 2015 and 2022 at two academic health care systems in a large metropolitan city. The exposure of interest was prosthetic fitting after LEA. The primary outcomes were mortality within 1 and 3 years of follow-up. Ambulation after LEA was defined as being ambulatory with or without an assistive device. Patients with prior LEA were excluded. Extended Cox models with time-dependent exposure were used to evaluate the association between prosthetic fitting and mortality at 1 and 3 years of follow-up. RESULTS: Among 702 patients who underwent LEA, the mean (SD) age was 64.3 (12.6) years and 329 (46.6%) were fitted for prosthetic. The study population was mostly male (n = 488, 69.5%), predominantly non-Hispanic Black (n = 410, 58.4%), and nearly one-fifth were non-ambulatory before LEA (n = 139 [19.8%]). Of note, 14.3% of all subjects who were nonambulatory at some point after LEA, and 28.5% of patients not ambulatory preoperatively were eventually ambulatory after LEA. The rate of death among those fitted for a prosthetic was 12.0/100 person-years at 1 year and 5.8/100 person-years at 3 years of follow-up; among those not fitted for a prosthetic, the rate of death was 55.7/100 person-years and 50.7/100 person-years at 1 and 3 years of follow-up, respectively. After adjusting for several sociodemographic data points, comorbidities, pre- or post- coronavirus disease 2019 pandemic timeframe, and procedural factors, prosthetic fitting is associated with decreased likelihood of mortality within 1 year of follow-up (adjusted hazard ratio, 0.24; 95% confidence interval, 0.14-0.40) as well as within 3 years (adjusted hazard ratio, 0.40; 95% confidence interval, 0.29-0.55). CONCLUSIONS: Prosthetic fitting is associated with improved survival, and preoperative functional status does not always predict postoperative functional status. Characterizing patient, surgical, and rehabilitation factors associated with receipt of prosthetic after LEA may improve long-term survival in these patients. Process measures employed by the Department of Veterans Affairs, such as prosthetic department evaluation of all amputees, may represent a best practice.


Sujet(s)
Amputation chirurgicale , Membres artificiels , Essayage de prothèse , Humains , Mâle , Femelle , Adulte d'âge moyen , Amputation chirurgicale/mortalité , Sujet âgé , Études rétrospectives , Facteurs de risque , Membre inférieur/vascularisation , Membre inférieur/chirurgie , Facteurs temps , Amputés/rééducation et réadaptation , COVID-19/mortalité , Appréciation des risques , Résultat thérapeutique
18.
Medicina (Kaunas) ; 60(5)2024 May 09.
Article de Anglais | MEDLINE | ID: mdl-38792967

RÉSUMÉ

Background and Objectives: mortality and morbidity due to cardiovascular causes are frequently experienced in amputees. Research on the effects of chronic exercise on biomarkers and cardiac damage indicators in these individuals is limited. The aim of this study was to investigate the effects of a core training program on brain natriuretic-related peptide, as well as hematological and biochemical parameters in amputee soccer players. Materials and Methods: The participants were randomly allocated to the following two groups: a core exercise group (CEG) and a control group (CG). While the CG continued routine soccer training, the CEG group was included in a core exercise program different from this group. During the study, routine hemogram parameters of the participants, various biochemical markers, and the concentration of brain natriuretic-related peptide (NT-pro-BNP) were analyzed. Results: after the training period, notable improvements in various hematological parameters were observed in both groups. In the CEG, there were significant enhancements in red blood cell count (RBC), hematocrit (HCT), mean corpuscular hemoglobin concentration (MCHC), and mean corpuscular hemoglobin (MCH) values. Similarly, the CG also showed substantial improvements in RBC, HCT, mean corpuscular volume (MCV), MCHC, MCH, red cell distribution width-standard deviation (RDW-SD), platelet-to-lymphocyte ratio (PLCR), mean platelet volume (MPV), and platelet distribution width (PDW). Moreover, in the CEG, serum triglycerides (TG) and maximal oxygen uptake (MaxVO2) exhibited significant increases. Conversely, TG levels decreased in the CG, while high-density lipoprotein (HDL), low-density lipoprotein (LDL), and MaxVO2 levels demonstrated substantial elevations. Notably, the N-terminal pro-brain natriuretic peptide (BNP) levels did not undergo significant changes in either the CEG or the CG following the core exercise program (p > 0.05). However, in the CEG, a meaningful positive correlation was observed between NT-pro-BNP and creatine kinase (CK) levels before and after the core exercise program. Conclusions: the findings emphasized the potential benefits of core training in enhancing specific physiological aspects, such as erythrocyte-related parameters and lipid metabolism, as well as aerobic capacity. Furthermore, the observed correlation between NT-pro-BNP and CK levels in the CEG provides intriguing insights into the unique physiological adaptations of amputee athletes.


Sujet(s)
Amputés , Athlètes , Exercice physique , Peptide natriurétique cérébral , Fragments peptidiques , Humains , Peptide natriurétique cérébral/sang , Mâle , Athlètes/statistiques et données numériques , Adulte , Exercice physique/physiologie , Fragments peptidiques/sang , Amputés/rééducation et réadaptation , Marqueurs biologiques/sang , Football/physiologie , Hématocrite/méthodes , Index érythrocytaires/physiologie
19.
J Rehabil Med ; 56: jrm34141, 2024 May 21.
Article de Anglais | MEDLINE | ID: mdl-38770700

RÉSUMÉ

OBJECTIVE: To describe and evaluate the combination of osseointegration and nerve transfers in 3 transhumeral amputees. DESIGN: Case series. PATIENTS: Three male patients with a unilateral traumatic transhumeral amputation. METHODS: Patients received a combination of osseointegration and targeted muscle reinnervation surgery. Rehabilitation included graded weight training, range of motion exercises, biofeedback, table-top prosthesis training, and controlling the actual device. The impairment in daily life, health-related quality of life, and pain before and after the intervention was evaluated in these patients. Their shoulder range of motion, prosthesis embodiment, and function were documented at a 2- to 5-year follow-up. RESULTS: All 3 patients attended rehabilitation and used their myoelectric prosthesis on a daily basis. Two patients had full shoulder range of motion with the prosthesis, while the other patient had 55° of abduction and 45° of anteversion. They became more independent in their daily life activities after the intervention and incorporated their prosthesis into their body scheme to a high extent. CONCLUSION: These results indicate that patients can benefit from the combined procedure. However, the patients' perspective, risks of the surgical procedures, and the relatively long rehabilitation procedure need to be incorporated in the decision-making.


Sujet(s)
Amputés , Membres artificiels , Transfert nerveux , Ostéo-intégration , Amplitude articulaire , Humains , Mâle , Ostéo-intégration/physiologie , Adulte , Amputés/rééducation et réadaptation , Transfert nerveux/méthodes , Amplitude articulaire/physiologie , Bionique , Résultat thérapeutique , Muscles squelettiques , Adulte d'âge moyen , Humérus/chirurgie , Qualité de vie , Amputation traumatique/rééducation et réadaptation , Amputation traumatique/chirurgie , Activités de la vie quotidienne
20.
Sci Rep ; 14(1): 11168, 2024 05 15.
Article de Anglais | MEDLINE | ID: mdl-38750086

RÉSUMÉ

It is essential that people with limb amputation maintain proper prosthetic socket fit to prevent injury. Monitoring and adjusting socket fit, for example by removing the prosthesis to add prosthetic socks, is burdensome and can adversely affect users' function and quality-of-life. This study presents results from take-home testing of a motor-driven adaptive socket that automatically adjusted socket size during walking. A socket fit metric was calculated from inductive sensor measurements of the distance between the elastomeric liner surrounding the residual limb and the socket's inner surface. A proportional-integral controller was implemented to adjust socket size. When tested on 12 participants with transtibial amputation, the controller was active a mean of 68% of the walking time. In general, participants who walked more than 20 min/day demonstrated greater activity, less doff time, and fewer manual socket size adjustments for the adaptive socket compared with a locked non-adjustable socket and a motor-driven socket that participants adjusted with a smartphone application. Nine of 12 participants reported that they would use a motor-driven adjustable socket if it were available as it would limit their socket fit issues. The size and weight of the adaptive socket were considered the most important variables to improve.


Sujet(s)
Amputation chirurgicale , Membres artificiels , Conception de prothèse , Tibia , Marche à pied , Humains , Mâle , Femelle , Adulte d'âge moyen , Tibia/chirurgie , Adulte , Essayage de prothèse/méthodes , Sujet âgé , Amputés/rééducation et réadaptation , Qualité de vie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE