Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 732
Filtrer
1.
Sci Rep ; 14(1): 12615, 2024 06 01.
Article de Anglais | MEDLINE | ID: mdl-38824217

RÉSUMÉ

Standard clinical practice to assess fetal well-being during labour utilises monitoring of the fetal heart rate (FHR) using cardiotocography. However, visual evaluation of FHR signals can result in subjective interpretations leading to inter and intra-observer disagreement. Therefore, recent studies have proposed deep-learning-based methods to interpret FHR signals and detect fetal compromise. These methods have typically focused on evaluating fixed-length FHR segments at the conclusion of labour, leaving little time for clinicians to intervene. In this study, we propose a novel FHR evaluation method using an input length invariant deep learning model (FHR-LINet) to progressively evaluate FHR as labour progresses and achieve rapid detection of fetal compromise. Using our FHR-LINet model, we obtained approximately 25% reduction in the time taken to detect fetal compromise compared to the state-of-the-art multimodal convolutional neural network while achieving 27.5%, 45.0%, 56.5% and 65.0% mean true positive rate at 5%, 10%, 15% and 20% false positive rate respectively. A diagnostic system based on our approach could potentially enable earlier intervention for fetal compromise and improve clinical outcomes.


Sujet(s)
Cardiotocographie , Apprentissage profond , Rythme cardiaque foetal , Rythme cardiaque foetal/physiologie , Humains , Grossesse , Femelle , Cardiotocographie/méthodes , , Surveillance de l'activité foetale/méthodes , Traitement du signal assisté par ordinateur , Foetus
2.
BMJ Open Qual ; 13(2)2024 Jun 05.
Article de Anglais | MEDLINE | ID: mdl-38839395

RÉSUMÉ

OBJECTIVES: In many countries, the healthcare sector is dealing with important challenges such as increased demand for healthcare services, capacity problems in hospitals and rising healthcare costs. Therefore, one of the aims of the Dutch government is to move care from in-hospital to out-of-hospital care settings. An example of an innovation where care is moved from a more specialised setting to a less specialised setting is the performance of an antenatal cardiotocography (aCTG) in primary midwife-led care. The aim of this study was to assess the budget impact of implementing aCTG for healthy pregnant women in midwife-led care compared with usual obstetrician-led care in the Netherlands. METHODS: A budget impact analysis was conducted to estimate the actual costs and reimbursement of aCTG performed in midwife-led care and obstetrician-led care (ie, base-case analysis) from the Dutch healthcare perspective. Epidemiological and healthcare utilisation data describing both care pathways were obtained from a prospective cohort, survey and national databases. Different implementation rates of aCTG in midwife-led care were explored. A probabilistic sensitivity analysis was conducted to estimate the uncertainty surrounding the budget impact estimates. RESULTS: Shifting aCTG from obstetrician-led care to midwife-led-care would increase actual costs with €311 763 (97.5% CI €188 574 to €426 072) and €1 247 052 (97.5% CI €754 296 to €1 704 290) for implementation rates of 25% and 100%, respectively, while it would decrease reimbursement with -€7 538 335 (97.5% CI -€10 302 306 to -€4 559 661) and -€30 153 342 (97.5% CI -€41 209 225 to -€18 238 645) for implementation rates of 25% and 100%, respectively. The sensitivity analysis results were consistent with those of the main analysis. CONCLUSIONS: From the Dutch healthcare perspective, we estimated that implementing aCTG in midwife-led care may increase the associated actual costs. At the same time, it might lower the healthcare reimbursement.


Sujet(s)
Budgets , Cardiotocographie , Profession de sage-femme , Humains , Femelle , Pays-Bas , Grossesse , Profession de sage-femme/statistiques et données numériques , Profession de sage-femme/économie , Profession de sage-femme/méthodes , Cardiotocographie/méthodes , Cardiotocographie/statistiques et données numériques , Cardiotocographie/économie , Cardiotocographie/normes , Budgets/statistiques et données numériques , Budgets/méthodes , Adulte , Études prospectives , Prise en charge prénatale/statistiques et données numériques , Prise en charge prénatale/économie , Prise en charge prénatale/méthodes
3.
Women Birth ; 37(4): 101619, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38754249

RÉSUMÉ

BACKGROUND: A variety of technologies are used to monitor fetal wellbeing in labour. Different types of fetal monitoring devices impact women's experiences of labour and birth. AIM: This review aims to understand how continuous electronic fetal monitoring (CEFM) influences women's experiences, with a focus on sense of control, active decision-making and mobility. METHODS: A systematic search of the literature was conducted. Findings from qualitative, quantitative and mixed methods studies were analysed to provide a review of current evidence. FINDINGS: Eighteen publications were included. The findings were synthesised into three themes: 'Feeling reassured versus anxious about the welfare of their baby', 'Feeling comfortable and free to be mobile versus feeling uncomfortable and restricted', and 'Feeling respected and empowered to make decisions versus feeling depersonalised with minimal control '. Women experienced discomfort and a lack of mobility as a result of some CEFM technologies. They often felt anxious and had mixed feelings about their baby's welfare whilst these were in use. Some women valued the data produced by CEFM technologies about the welfare of their baby. Many women experienced a sense of depersonalisation and lack of control whilst CEFM technologies were used. DISCUSSION: Fetal monitoring technologies influence women's experiences of labour both positively and negatively. Wireless devices were associated with the most positive response as they enabled greater freedom of movement. CONCLUSION: The design of emerging fetal monitoring technologies should incorporate elements which foster freedom of movement, are comfortable and provide women with a sense of choice and control. The implementation of fetal monitoring that enables these elements should be prioritised by health professionals.


Sujet(s)
Surveillance de l'activité foetale , Travail obstétrical , Femelle , Humains , Grossesse , Cardiotocographie/méthodes , Prise de décision , Pays développés , Surveillance de l'activité foetale/méthodes , Travail obstétrical/psychologie , Femmes enceintes/psychologie
4.
J Perinat Med ; 52(6): 597-603, 2024 Jul 26.
Article de Anglais | MEDLINE | ID: mdl-38682857

RÉSUMÉ

OBJECTIVES: To compare characteristics of labor, cardiotocography traces, and maternal and neonatal outcomes, in a cohort of pregnancies at term complicated by maternal intrapartum pyrexia, with or without a histologic diagnosis of chorioamnionitis. METHODS: This is a retrospective case-control study including pregnancies at term with detection of maternal intrapartum pyrexia, delivered between January 2020 and June 2021. Cardiotocography traces were entirely evaluated, since admission till delivery, and classified according to the International Federation of Obstetrics and Gynecology (FIGO) guideline. Maternal and neonatal outcomes were also recorded as secondary outcomes. Placentas have been studied according to the Amniotic Fluid Infection Nosology Committee. RESULTS: Forty four patients met the inclusion criteria and were included in the study cohort. There was a significant association between the use of oxytocin augmentation in labor and the histologic diagnosis of chorioamnionitis. A significative recurrence of loss and/or absence of accelerations at the point of pyrexia was also documented in women with histological chorioamnionitis compared to the others. CONCLUSIONS: Chorioamnionitis appears to be associated with myometrial disfunction, as suggested by the increased use of oxytocin augmentation during active labor of women at term with intrapartum pyrexia and histologic diagnosis of chorioamnionitis.


Sujet(s)
Cardiotocographie , Chorioamnionite , Fièvre , Humains , Femelle , Chorioamnionite/diagnostic , Grossesse , Études cas-témoins , Cardiotocographie/méthodes , Adulte , Études rétrospectives , Fièvre/diagnostic , Fièvre/étiologie , Ocytocine/administration et posologie , Nouveau-né
6.
Comput Methods Programs Biomed ; 249: 108145, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38582038

RÉSUMÉ

BACKGROUND AND OBJECTIVE: Obstetricians use Cardiotocography (CTG), which is the continuous recording of fetal heart rate and uterine contraction, to assess fetal health status. Deep learning models for intelligent fetal monitoring trained on extensively labeled and identically distributed CTG records have achieved excellent performance. However, creation of these training sets requires excessive time and specialist labor for the collection and annotation of CTG signals. Previous research has demonstrated that multicenter studies can improve model performance. However, models trained on cross-domain data may not generalize well to target domains due to variance in distribution among datasets. Hence, this paper conducted a multicenter study with Deep Semi-Supervised Domain Adaptation (DSSDA) for intelligent interpretation of antenatal CTG signals. This approach helps to align cross-domain distribution and transfer knowledge from a label-rich source domain to a label-scarce target domain. METHODS: We proposed a DSSDA framework that integrated Minimax Entropy and Domain Invariance (DSSDA-MMEDI) to reduce inter-domain gaps and thus achieve domain invariance. The networks were developed using GoogLeNet to extract features from CTG signals, with fully connected, softmax layers for classification. We designed a Dynamic Gradient-driven strategy based on Mutual Information (DGMI) to unify the losses from Minimax Entropy (MME), Domain Invariance (DI), and supervised cross-entropy during iterative learning. RESULTS: We validated our DSSDA model on two datasets collected from collaborating healthcare institutions and mobile terminals as the source and target domains, which contained 16,355 and 3,351 CTG signals, respectively. Compared to the results achieved with deep learning networks without DSSDA, DSSDA-MMEDI significantly improved sensitivity and F1-score by over 6%. DSSDA-MMEDI also outperformed other state-of-the-art DSSDA approaches for CTG signal interpretation. Ablation studies were performed to determine the unique contribution of each component in our DSSDA mechanism. CONCLUSIONS: The proposed DSSDA-MMEDI is feasible and effective for alignment of cross-domain data and automated interpretation of multicentric antenatal CTG signals with minimal annotation cost.


Sujet(s)
Cardiotocographie , Surveillance de l'activité foetale , Grossesse , Femelle , Humains , Cardiotocographie/méthodes , Entropie , Surveillance de l'activité foetale/méthodes , Contraction utérine , Rythme cardiaque foetal/physiologie
9.
Int J Gynaecol Obstet ; 166(2): 859-870, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38441244

RÉSUMÉ

OBJECTIVE: To identify new parameters predicting fetal acidemia. METHODS: A retrospective case-control study in a cohort of deliveries from a tertiary referral hospital-based cohort deliveries in Zaragoza, Spain between 2018 and 2021 was performed. To predict fetal acidemia, the NICHD categorizations and non-NICHD parameters were analyzed in the electronic fetal monitoring (EFM). Those included total reperfusion time, total deceleration area and the slope of the descending limb of the fetal heart rate of the last deceleration curve. The accuracy of the parameters was evaluated using the specificity for (80%, 85%, 90%, 95%) sensitivity and the area under the receiver operating characteristic curve (AUC). RESULTS: A total of 10 362 deliveries were reviewed, with 224 cases and 278 controls included in the study. The NICHD categorizations showed reasonable discriminatory ability (AUC = 0.727). The non-NICHD parameters measured during the 30-min fetal monitoring, total deceleration area (AUC = 0.807, 95% CI: 0.770, 0.845) and total reperfusion time (AUC = 0.750, 95% CI: 0.707, 0.792), exhibited higher discriminatory ability. The slope of the descending limb of the fetal heart rate of the last deceleration curve had the best AUC value (0.853, 95% CI: 0.816, 0.889). The combination of total deceleration area or total reperfusion time with the slope demonstrated high discriminatory ability (AUC = 0.908, 95% CI: 0.882, 0.933; specificities of 71.6% and 72.7% for a sensitivity of 90%). CONCLUSIONS: The slope of the descending limb of the fetal heart rate of the last deceleration curve is the strongest predictor of fetal acidosis, but its combination with the total reperfusion time shows better clinical utility.


Sujet(s)
Acidose , Cardiotocographie , Maladies foetales , Rythme cardiaque foetal , Humains , Femelle , Grossesse , Rythme cardiaque foetal/physiologie , Acidose/diagnostic , Études rétrospectives , Études cas-témoins , Cardiotocographie/méthodes , Maladies foetales/diagnostic , Adulte , Décélération , Espagne , Courbe ROC , Surveillance de l'activité foetale/méthodes , Sensibilité et spécificité
10.
Midwifery ; 132: 103978, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38555829

RÉSUMÉ

BACKGROUND: The purpose of cardiotocograph (CTG) usage is to detect any alterations in fetal heart rate (FHR) early before they are prolonged and profound. However, the use of CTG machines on a routine basis is not an evidence-supported practice. There is no Jordanian study that assesses the midwives' attitudes toward this machine. This study aimed to identify Jordanian midwives' attitudes towards the use of cardiotocograph (CTG) machines in labor units, alongside examining the relationships between midwives' personal sociodemographic characteristics and such attitudes. METHODS: A descriptive research design was used to identify Jordanian midwives' attitudes towards the use of CTG machines in both public and private labor units in Jordan. Data were collected using the valid and reliable tool designed by Sinclair (2001), and these were used to identify midwives' attitudes towards CTG usage. A total of 329 midwives working in the labor units of governmental and private hospitals in the center and north of Jordan participated in the study from May to July 2022. RESULTS: The total mean score for the attitude scale was M = 3.14 (SD = 0.83). More than half of the sample (N = 187, 58.4 %) demonstrated a mean score greater than 3.14, however, which indicates generally positive attitudes toward CTG usage in labor units. Midwives working in private hospitals and those holding Bachelor's degrees had more positive attitudes toward the use of CTG machines. CONCLUSION: This study provides new insights into the attitudes of Jordanian midwives towards CTG use in labor units. These suggest that it is critical to conduct training courses for registered midwives to help them develop and/or regain confidence and competence with respect to various key aspects of intrapartum care, including intermittent auscultation and the appropriate use of CTG.


Sujet(s)
Attitude du personnel soignant , Cardiotocographie , Humains , Jordanie , Femelle , Cardiotocographie/méthodes , Cardiotocographie/statistiques et données numériques , Cardiotocographie/normes , Adulte , Enquêtes et questionnaires , Grossesse , Infirmières sages-femmes/psychologie , Infirmières sages-femmes/statistiques et données numériques , Adulte d'âge moyen , Profession de sage-femme/méthodes , Profession de sage-femme/statistiques et données numériques
11.
Comput Biol Med ; 172: 108220, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38489990

RÉSUMÉ

INTRODUCTION: Uterine contractions during labour constrict maternal blood flow and oxygen delivery to the developing baby, causing transient hypoxia. While most babies are physiologically adapted to withstand such intrapartum hypoxia, those exposed to severe hypoxia or with poor physiological reserves may experience neurological injury or death during labour. Cardiotocography (CTG) monitoring was developed to identify babies at risk of hypoxia by detecting changes in fetal heart rate (FHR) patterns. CTG monitoring is in widespread use in intrapartum care for the detection of fetal hypoxia, but the clinical utility is limited by a relatively poor positive predictive value (PPV) of an abnormal CTG and significant inter and intra observer variability in CTG interpretation. Clinical risk and human factors may impact the quality of CTG interpretation. Misclassification of CTG traces may lead to both under-treatment (with the risk of fetal injury or death) or over-treatment (which may include unnecessary operative interventions that put both mother and baby at risk of complications). Machine learning (ML) has been applied to this problem since early 2000 and has shown potential to predict fetal hypoxia more accurately than visual interpretation of CTG alone. To consider how these tools might be translated for clinical practice, we conducted a review of ML techniques already applied to CTG classification and identified research gaps requiring investigation in order to progress towards clinical implementation. MATERIALS AND METHOD: We used identified keywords to search databases for relevant publications on PubMed, EMBASE and IEEE Xplore. We used Preferred Reporting Items for Systematic Review and Meta-Analysis for Scoping Reviews (PRISMA-ScR). Title, abstract and full text were screened according to the inclusion criteria. RESULTS: We included 36 studies that used signal processing and ML techniques to classify CTG. Most studies used an open-access CTG database and predominantly used fetal metabolic acidosis as the benchmark for hypoxia with varying pH levels. Various methods were used to process and extract CTG signals and several ML algorithms were used to classify CTG. We identified significant concerns over the practicality of using varying pH levels as the CTG classification benchmark. Furthermore, studies needed to be more generalised as most used the same database with a low number of subjects for an ML study. CONCLUSION: ML studies demonstrate potential in predicting fetal hypoxia from CTG. However, more diverse datasets, standardisation of hypoxia benchmarks and enhancement of algorithms and features are needed for future clinical implementation.


Sujet(s)
Cardiotocographie , Travail obstétrical , Femelle , Humains , Grossesse , Cardiotocographie/méthodes , Hypoxie foetale/diagnostic , Rythme cardiaque foetal/physiologie , Contraction utérine
12.
J Obstet Gynecol Neonatal Nurs ; 53(3): e10-e48, 2024 05.
Article de Anglais | MEDLINE | ID: mdl-38363241

RÉSUMÉ

Intermittent auscultation (IA) is an evidence-based method of fetal surveillance during labor for birthing people with low-risk pregnancies. It is a central component of efforts to reduce the primary cesarean rate and promote vaginal birth (American College of Obstetricians and Gynecologists, 2019; Association of Women's Health, Obstetric and Neonatal Nurses, 2022a). The use of intermittent IA decreased with the introduction of electronic fetal monitoring, while the increased use of electronic fetal monitoring has been associated with an increase of cesarean births. This practice monograph includes information on IA techniques; interpretation and documentation; clinical decision-making and interventions; communication; education, staffing, legal issues; and strategies to implement IA.


Sujet(s)
Surveillance de l'activité foetale , Rythme cardiaque foetal , Humains , Femelle , Grossesse , Rythme cardiaque foetal/physiologie , Surveillance de l'activité foetale/méthodes , Auscultation cardiaque/méthodes , Auscultation/méthodes , Cardiotocographie/méthodes , Cardiotocographie/normes
13.
Nurs Womens Health ; 28(2): e1-e39, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38363259

RÉSUMÉ

Intermittent auscultation (IA) is an evidence-based method of fetal surveillance during labor for birthing people with low-risk pregnancies. It is a central component of efforts to reduce the primary cesarean rate and promote vaginal birth (American College of Obstetricians and Gynecologists, 2019; Association of Women's Health, Obstetric and Neonatal Nurses, 2022a). The use of intermittent IA decreased with the introduction of electronic fetal monitoring, while the increased use of electronic fetal monitoring has been associated with an increase of cesarean births. This practice monograph includes information on IA techniques; interpretation and documentation; clinical decision-making and interventions; communication; education, staffing, legal issues; and strategies to implement IA.


Sujet(s)
Surveillance de l'activité foetale , Travail obstétrical , Grossesse , Nouveau-né , Femelle , Humains , Surveillance de l'activité foetale/méthodes , Rythme cardiaque foetal , Auscultation/méthodes , Cardiotocographie/méthodes
14.
Eur J Obstet Gynecol Reprod Biol ; 295: 75-85, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38340594

RÉSUMÉ

OBJECTIVE: To assess whether artificial intelligence, inspired by clinical decision-making procedures in delivery rooms, can correctly interpret cardiotocographic tracings and distinguish between normal and pathological events. STUDY DESIGN: A method based on artificial intelligence was developed to determine whether a cardiotocogram shows a normal response of the fetal heart rate to uterine activity (UA). For a given fetus and given the UA and previous FHR, the method predicts a fetal heart rate response, under the assumption that the fetus is still in good condition and based on how that specific fetus has responded so far. We hypothesize that this method, when having only learned from fetuses born in good condition, is incapable of predicting the response of a compromised fetus or an episode of transient fetal distress. The (in)capability of the method to predict the fetal heart rate response would then yield a method that can help to assess fetal condition when the obstetrician is in doubt. Cardiotocographic data of 678 deliveries during labor were selected based on a healthy outcome just after birth. The method was trained on the cardiotocographic data of 548 fetuses of this group to learn their heart rate response. Subsequently it was evaluated on 87 fetuses, by assessing whether the method was able to predict their heart rate responses. The remaining 43 cardiotocograms were segment-by-segment annotated by three experienced gynecologists, indicating normal, suspicious, and pathological segments, while having access to the full recording and neonatal outcome. This future knowledge makes the expert annotations of a quality that is unachievable during live interpretation. RESULTS: The comparison between abnormalities detected by the method (only using past and present input) and the annotated CTG segments by gynecologists (also looking at future input) yields an area under the curve of 0.96 for the distinction between normal and pathological events in majority-voted annotations. CONCLUSION: The developed method can distinguish between normal and pathological events in near real-time, with a performance close to the agreement between three gynecologists with access to the entire CTG tracing and fetal outcome. The method has a strong potential to support clinicians in assessing fetal condition in clinical practice.


Sujet(s)
Maladies foetales , Travail obstétrical , Grossesse , Femelle , Nouveau-né , Humains , Cardiotocographie/méthodes , Intelligence artificielle , Travail obstétrical/physiologie , Prise en charge prénatale , Rythme cardiaque foetal/physiologie
15.
BMC Pregnancy Childbirth ; 24(1): 136, 2024 Feb 14.
Article de Anglais | MEDLINE | ID: mdl-38355457

RÉSUMÉ

BACKGROUND: While the effectiveness of cardiotocography in reducing neonatal morbidity is still debated, it remains the primary method for assessing fetal well-being during labor. Evaluating how accurately professionals interpret cardiotocography signals is essential for its effective use. The objective was to evaluate the accuracy of fetal hypoxia prediction by practitioners through the interpretation of cardiotocography signals and clinical variables during labor. MATERIAL AND METHODS: We conducted a cross-sectional online survey, involving 120 obstetric healthcare providers from several countries. One hundred cases, including fifty cases of fetal hypoxia, were randomly assigned to participants who were invited to predict the fetal outcome (binary criterion of pH with a threshold of 7.15) based on the cardiotocography signals and clinical variables. After describing the participants, we calculated (with a 95% confidence interval) the success rate, sensitivity and specificity to predict the fetal outcome for the whole population and according to pH ranges, professional groups and number of years of experience. Interobserver agreement and reliability were evaluated using the proportion of agreement and Cohen's kappa respectively. RESULTS: The overall ability to predict a pH level below 7.15 yielded a success rate of 0.58 (95% CI 0.56-0.60), a sensitivity of 0.58 (95% CI 0.56-0.60) and a specificity of 0.63 (95% CI 0.61-0.65). No significant difference in the success rates was observed with respect to profession and number of years of experience. The success rate was higher for the cases with a pH level below 7.05 (0.69) and above 7.20 (0.66) compared to those falling between 7.05 and 7.20 (0.48). The proportion of agreement between participants was good (0.82), with an overall kappa coefficient indicating substantial reliability (0.63). CONCLUSIONS: The use of an online tool enabled us to collect a large amount of data to analyze how practitioners interpret cardiotocography data during labor. Despite a good level of agreement and reliability among practitioners, the overall accuracy is poor, particularly for cases with a neonatal pH between 7.05 and 7.20. Factors such as profession and experience level do not present notable impact on the accuracy of the annotations. The implementation and use of a computerized cardiotocography analysis software has the potential to enhance the accuracy to detect fetal hypoxia, especially for ambiguous cardiotocography tracings.


Sujet(s)
Cardiotocographie , Hypoxie foetale , Grossesse , Nouveau-né , Femelle , Humains , Cardiotocographie/méthodes , Hypoxie foetale/diagnostic , Biais de l'observateur , Reproductibilité des résultats , Études transversales , Rythme cardiaque foetal
16.
Int J Gynaecol Obstet ; 166(2): 580-595, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38287690

RÉSUMÉ

BACKGROUND: The use of cardiotocography (CTG) to improve neonatal outcomes is controversial. The medical settings, subjects, utilizations, and interpretation guidelines of CTG are unclear for low- and middle-income countries (LMICs). OBJECTIVES: To assess and review CTG use for studies identified in LMICs and provide insights on the potential for effective use of CTG to improve maternal and neonatal outcomes. SEARCH STRATEGY: The databases Medline, CINAHL, EMBASE, and Cochrane Central Register of Controlled Trials (CENTRAL) were searched for published and unpublished literature through September 2023. SELECTION CRITERIA: Publications were identified which were conducted in LMICs, based on the World Bank list of economies for 2019; targeting pregnant women in childbirth; and focusing on the utilization of CTG and neonatal outcomes. DATA COLLECTION AND ANALYSIS: Publications were screened, and duplicates were removed. A scoping review was conducted using PRISMA-ScR guidelines. RESULTS: The searches generated 1157 hits, of which 67 studies were included in the review. In the studies there was considerable variation and ambiguity regarding the study settings, target populations, utilizations, timing, frequency, and duration of CTG. While cesarean section rates were extensively investigated as an outcome of studies of CTG itself and the effect of additional techniques on CTG, other clinically significant outcomes, including neonatal mortality, were not well reported. CONCLUSIONS: Variations and ambiguities were found in the use of CTG in LMICs. Due to the limited amount of evidence, studies are needed to examine CTG availability in the context of LMICs.


Sujet(s)
Cardiotocographie , Pays en voie de développement , Travail obstétrical , Humains , Grossesse , Femelle , Cardiotocographie/méthodes , Césarienne/statistiques et données numériques , Nouveau-né , Rythme cardiaque foetal , Issue de la grossesse
17.
Acta Obstet Gynecol Scand ; 103(5): 980-991, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38229258

RÉSUMÉ

INTRODUCTION: In clinical practice, fetal heart rate monitoring is performed intermittently using Doppler ultrasound, typically for 30 minutes. In case of a non-reassuring heart rate pattern, monitoring is usually prolonged. Noninvasive fetal electrocardiography may be more suitable for prolonged monitoring due to improved patient comfort and signal quality. This study evaluates the performance and patient experience of four noninvasive electrocardiography devices to assess candidate devices for prolonged noninvasive fetal heart rate monitoring. MATERIAL AND METHODS: Non-critically sick women with a singleton pregnancy from 24 weeks of gestation were eligible for inclusion. Fetal heart rate monitoring was performed during standard care with a Doppler ultrasound device (Philips Avalon-FM30) alone or with this Doppler ultrasound device simultaneously with one of four noninvasive electrocardiography devices (Nemo Fetal Monitoring System, Philips Avalon-Beltless, Demcon Dipha-16 and Dräger Infinity-M300). Performance was evaluated by: success rate, positive percent agreement, bias, 95% limits of agreement, regression line, root mean square error and visual agreement using FIGO guidelines. Patient experience was captured using a self-made questionnaire. RESULTS: A total of 10 women were included per device. For fetal heart rate, Nemo performed best (success rate: 99.4%, positive percent agreement: 94.2%, root mean square error 5.1 BPM, bias: 0.5 BPM, 95% limits of agreement: -9.7 - 10.7 BPM, regression line: y = -0.1x + 11.1) and the cardiotocography tracings obtained simultaneously by Nemo and Avalon-FM30 received the same FIGO classification. Comparable results were found with the Avalon-Beltless from 36 weeks of gestation, whereas the Dipha-16 and Infinity-M300 performed significantly worse. The Avalon-Beltless, Nemo and Infinity-M300 closely matched the performance of the Avalon-FM30 for maternal heart rate, whereas the performance of the Dipha-16 deviated more. Patient experience scores were higher for the noninvasive electrocardiography devices. CONCLUSIONS: Both Nemo and Avalon-Beltless are suitable devices for (prolonged) noninvasive fetal heart rate monitoring, taking their intended use into account. But outside its intended use limit of 36 weeks' gestation, the Avalon-Beltless performs less well, comparable to the Dipha-16 and Infinity-M300, making them currently unsuitable for (prolonged) noninvasive fetal heart rate monitoring. Noninvasive electrocardiography devices appear to be preferred due to greater comfort and mobility.


Sujet(s)
Cardiotocographie , Mesure de la fréquence cardiaque , Grossesse , Femelle , Humains , Cardiotocographie/méthodes , Surveillance de l'activité foetale/méthodes , Électrocardiographie , Rythme cardiaque foetal/physiologie , Évaluation des résultats des patients
18.
Am J Obstet Gynecol ; 230(4): 379.e1-379.e12, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38272284

RÉSUMÉ

BACKGROUND: Intrapartum cardiotocographic monitoring of fetal heart rate by abdominal external ultrasound transducer without simultaneous maternal heart rate recording has been associated with increased risk of early neonatal death and other asphyxia-related neonatal outcomes. It is unclear, however, whether this increase in risk is independently associated with fetal surveillance method or is attributable to other factors. OBJECTIVE: This study aimed to compare different fetal surveillance methods and their association with adverse short- and long-term fetal and neonatal outcomes in a large retrospective cohort of spontaneous term deliveries. STUDY DESIGN: Fetal heart rate and maternal heart rate patterns were recorded by cardiotocography during labor in spontaneous term singleton cephalic vaginal deliveries in the Hospital District of Helsinki and Uusimaa, Finland between October 1, 2005, and September 30, 2023. According to the method of cardiotocography monitoring at birth, the cohort was divided into the following 3 groups: women with ultrasound transducer, women with both ultrasound transducer and maternal heart rate transducer, and women with internal fetal scalp electrode. Umbilical artery pH and base excess values, low 1- and 5-minute Apgar scores, need for intubation and resuscitation, neonatal intensive care unit admission for asphyxia, neonatal encephalopathy, and early neonatal death were used as outcome variables. RESULTS: Among the 213,798 deliveries that met the inclusion criteria, the monitoring type was external ultrasound transducer in 81,559 (38.1%), both external ultrasound transducer and maternal heart rate recording in 62,268 (29.1%), and fetal scalp electrode in 69,971 (32.7%) cases, respectively. The rates of both neonatal encephalopathy (odds ratio, 1.48; 95% confidence interval, 1.08-2.02) and severe acidemia (umbilical artery pH <7.00 and/or umbilical artery base excess ≤-12.0 mmol/L) (odds ratio, 2.03; 95% confidence interval, 1.65-2.50) were higher in fetuses of women with ultrasound transducer alone compared with those of women with concurrent external fetal and maternal heart rate recording. Monitoring with ultrasound transducer alone was also associated with increased risk of neonatal intubation for resuscitation (odds ratio, 1.22; 95% confidence interval, 1.03-1.44). A greater risk of severe neonatal acidemia was observed both in the ultrasound transducer (odds ratio, 2.78; 95% confidence interval, 2.23-3.48) and concurrent ultrasound transducer and maternal heart rate recording (odds ratio, 1.37; 95% confidence interval, 1.05-1.78) groups compared with those monitored with fetal scalp electrodes. No difference in risk of neonatal encephalopathy was found between newborns monitored with concurrent ultrasound transducer and maternal heart rate recording and those monitored with fetal scalp electrodes. CONCLUSION: The use of external ultrasound transducer monitoring of fetal heart rate without simultaneous maternal heart rate recording is associated with higher rates of neonatal encephalopathy and severe neonatal acidemia. We suggest that either external fetal heart rate monitoring with concurrent maternal heart rate recording or internal fetal scalp electrode be used routinely as a fetal surveillance tool in term deliveries.


Sujet(s)
Encéphalopathies , Maladies néonatales , Mort périnatale , Grossesse , Nouveau-né , Femelle , Humains , Cardiotocographie/méthodes , Études rétrospectives , Asphyxie , Rythme cardiaque foetal/physiologie
19.
Acta Obstet Gynecol Scand ; 103(3): 437-448, 2024 Mar.
Article de Anglais | MEDLINE | ID: mdl-38093630

RÉSUMÉ

INTRODUCTION: ST waveform analysis (STAN) was introduced as an adjunct to cardiotocography (CTG) to improve neonatal and maternal outcomes. The aim of the present study was to quantify the efficacy of STAN vs CTG and assess the quality of the evidence using GRADE. MATERIAL AND METHODS: We performed systematic literature searches to identify randomized controlled trials and assessed included studies for risk of bias. We performed meta-analyses, calculating pooled risk ratio (RR) or Peto odds ratio (OR). We also performed post hoc trial sequential analyses for selected outcomes to assess the risk of false-positive results and the need for additional studies. RESULTS: Nine randomized controlled trials including 28 729 women were included in the meta-analysis. There were no differences between the groups in operative deliveries for fetal distress (10.9 vs 11.1%; RR 0.96; 95% confidence interval [CI] 0.82-1.11). STAN was associated with a significantly lower rate of metabolic acidosis (0.45% vs 0.68%; Peto OR 0.66; 95% CI 0.48-0.90). Accordingly, 441 women need to be monitored with STAN instead of CTG alone to prevent one case of metabolic acidosis. Women allocated to STAN had a reduced risk of fetal blood sampling compared with women allocated to conventional CTG monitoring (12.5% vs 19.6%; RR 0.62; 95% CI 0.49-0.80). The quality of the evidence was high to moderate. CONCLUSIONS: Absolute effects of STAN were minor and the clinical significance of the observed reduction in metabolic acidosis is questioned. There is insufficient evidence to state that STAN as an adjunct to CTG leads to important clinical benefits compared with CTG alone.


Sujet(s)
Acidose , Cardiotocographie , Grossesse , Nouveau-né , Femelle , Humains , Cardiotocographie/méthodes , Essais contrôlés randomisés comme sujet , Souffrance foetale/diagnostic , Électrocardiographie/méthodes , Acidose/diagnostic , Acidose/prévention et contrôle , Surveillance de l'activité foetale/méthodes , Rythme cardiaque foetal
20.
Aust N Z J Obstet Gynaecol ; 64(1): 77-79, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-37702257

RÉSUMÉ

Monitoring the fetal heartbeat underpins assessment of fetal wellbeing in labour. Although commonly employed in clinical practice, shortcomings remain. A recent review of clinical practice guidelines highlights the variation in definitions of the fetal heart rate that will lead to differences in interpretation. Will intrapartum care be improved by greater consensus around clinical practice guidelines through rationalisation or refinement of guidelines, or will the future see this technique replaced by more accurate forms of fetal monitoring?


Sujet(s)
Cardiotocographie , Travail obstétrical , Grossesse , Femelle , Humains , Cardiotocographie/méthodes , Mesure de la fréquence cardiaque , Surveillance de l'activité foetale/méthodes , Prévision , Rythme cardiaque foetal
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...