Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 593
Filtrer
1.
J Cardiovasc Electrophysiol ; 35(8): 1656-1662, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38924288

RÉSUMÉ

INTRODUCTION: Access site complications remain common following atrial fibrillation (AF) catheter ablation. Femoral vascular closure devices (VCDs) reduce time to hemostasis compared with manual compression, although large-scale data comparing clinical outcomes between the two approaches are lacking. METHODS: Two cohorts of patients undergoing AF ablation were identified from 36 healthcare organizations using a global federated research network (TriNetX): those receiving a VCD for femoral hemostasis, and those not receiving a VCD. A 1:1 propensity score matching (PSM) model based on baseline characteristics was used to create two comparable cohorts. The primary outcome was a composite of all-cause mortality, vascular complications, bleeding events, and need for blood transfusion. Outcomes were assessed during early (within 7 days of ablation) and extended follow-up (within 8-30 days of ablation). RESULTS: After PSM, 28 872 patients were included (14 436 in each cohort). The primary composite outcome occurred less frequently in the VCD cohort during early (1.97% vs. 2.60%, odds ratio (OR) 0.76, 95% confidence interval (CI) 0.65-0.88; p < .001) and extended follow-up (1.15% vs. 1.43%, OR 0.80, 95% CI 0.65-0.98; p = .032). This was driven by a lower rate of vascular complications during early follow-up in the VCD cohort (0.83% vs. 1.26%, OR 0.66, 95% CI 0.52-0.83; p < .001), and fewer bleeding events during early (0.90% vs. 1.23%, OR 0.73, 95% CI 0.58-0.92; p = .007) and extended follow-up (0.36% vs. 0.59%, OR 0.61, 95% CI 0.43-0.86; p = .005). CONCLUSION: Following AF ablation, femoral venous hemostasis with a VCD was associated with reduced complications compared with hemostasis without a VCD.


Sujet(s)
Fibrillation auriculaire , Ablation par cathéter , Veine fémorale , Techniques d'hémostase , Ponctions , Dispositifs de fermeture vasculaire , Humains , Fibrillation auriculaire/chirurgie , Fibrillation auriculaire/diagnostic , Fibrillation auriculaire/physiopathologie , Mâle , Femelle , Ablation par cathéter/effets indésirables , Adulte d'âge moyen , Résultat thérapeutique , Sujet âgé , Facteurs temps , Techniques d'hémostase/instrumentation , Techniques d'hémostase/effets indésirables , Facteurs de risque , Études rétrospectives , Cathétérisme périphérique/effets indésirables , Appréciation des risques , Hémorragie/étiologie , Hémorragie/prévention et contrôle
2.
World Neurosurg ; 188: e305-e311, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38796148

RÉSUMÉ

OBJECTIVE: Puncture-site complications in interventional radiology sometimes cause severe conditions. Vascular closure devices play an important role in preventing puncture-site complications. Vascular closure devices are divided into 2 types, the directly suturing or clipping type (active approximators) and adherent sealant types (passive approximators). However, which types of vascular closure device are the safest and most effective for achieving hemostasis remains unclear. We analyzed the efficacy of each type of vascular closure device and risk factors for puncture-site complications. METHODS: This study investigated 327 consecutive cases of neuroendovascular surgery using a transfemoral procedure during a 2-year study period. Passive approximators (Angioseal [St Jude Medical, Saint Paul, MN] and Exoseal [Cordis Corporation, Miami, FL]) were mainly used in the first half and active approximators (Perclose [Abbot Vascular, Santa Clara, CA]) in the second. We compared groups and estimated risk factors for puncture-site complications. RESULTS: All procedures were successful. Comparing groups with and without puncture-site complications, use of passive approximators and ≥3 antithrombotic medications tended to be more frequent and distance from skin to femoral artery and body mass index tended to be lower in the group with complications without significance. The cutoff for femoral artery depth calculated from a receiver operating characteristic curve was 16.43 mm. Multivariate analysis revealed ≥3 antithrombotic medications (P = 0.002, OR 15.29, 95% CI 2.76-85.76) and passive approximator use in patients with femoral artery depth <16.43 mm (P < 0.001, OR 17.08, 95% CI 2.95-57.80) were significantly higher in the group with puncture-site complications. CONCLUSIONS: Passive approximator use in patients with shallow femoral artery depth increases puncture-site complications in neuroendovascular treatment.


Sujet(s)
Procédures endovasculaires , Artère fémorale , Ponctions , Dispositifs de fermeture vasculaire , Humains , Artère fémorale/chirurgie , Mâle , Femelle , Adulte d'âge moyen , Sujet âgé , Ponctions/effets indésirables , Procédures endovasculaires/effets indésirables , Procédures endovasculaires/méthodes , Adulte , Facteurs de risque , Études rétrospectives , Sujet âgé de 80 ans ou plus
4.
Circ Cardiovasc Interv ; 17(6): e013842, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38708595

RÉSUMÉ

BACKGROUND: An increasing number of interventional procedures require large-sheath technology (>12F) with a favorable outcome with endovascular rather than open surgical access. However, vascular complications are a limitation for the management of these patients. This trial aimed to determine the effectiveness and safety of the Cross-Seal suture-mediated vascular closure device in obtaining hemostasis at the target limb access site following interventional procedures using 8F to 18F procedural sheaths. METHODS: The Cross-Seal IDE trial (Investigational Device Exemption) was a prospective, single-arm, multicenter study in subjects undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheaths. The primary efficacy end point was time to hemostasis at the target limb access site. The primary safety end point was freedom from major complications of the target limb access site within 30 days post procedure. RESULTS: A total of 147 subjects were enrolled between August 9, 2019, and March 12, 2020. Transcatheter aortic valve replacement was performed in 53.7% (79/147) and percutaneous endovascular abdominal/thoracic aortic aneurysm repair in 46.3% (68/147) of subjects. The mean sheath ID was 15.5±1.8 mm. The primary effectiveness end point of time to hemostasis was 0.4±1.4 minutes. An adjunctive intervention was required in 9.2% (13/142) of subjects, of which 2.1% (3/142) were surgical and 5.6% (8/142) endovascular. Technical success was achieved in 92.3% (131/142) of subjects. Freedom from major complications of the target limb access site was 94.3% (83/88). CONCLUSIONS: In selected patients undergoing percutaneous endovascular procedures utilizing 8F to 18F ID procedural sheath, Cross-Seal suture-mediated vascular closure device achieved favorable effectiveness and safety in the closure of the large-bore arteriotomy. REGISTRATION: URL: https://www.clinicaltrials.gov; Unique identifier: NCT03756558.


Sujet(s)
Procédures endovasculaires , Techniques d'hémostase , Techniques de suture , Dispositifs de fermeture vasculaire , Humains , Études prospectives , Mâle , Femelle , Sujet âgé , Techniques d'hémostase/instrumentation , Techniques d'hémostase/effets indésirables , Résultat thérapeutique , Facteurs temps , Techniques de suture/effets indésirables , Techniques de suture/instrumentation , Procédures endovasculaires/effets indésirables , Procédures endovasculaires/instrumentation , Sujet âgé de 80 ans ou plus , Conception d'appareillage , Ponctions , Cathétérisme périphérique/effets indésirables , Cathétérisme périphérique/instrumentation , Hémorragie/prévention et contrôle , Hémorragie/étiologie , Adulte d'âge moyen , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/instrumentation , Facteurs de risque , Anévrysme de l'aorte abdominale/chirurgie , Anévrysme de l'aorte abdominale/imagerie diagnostique , Implantation de prothèses vasculaires/effets indésirables , Implantation de prothèses vasculaires/instrumentation , Anévrysme de l'aorte thoracique/chirurgie , Anévrysme de l'aorte thoracique/imagerie diagnostique
5.
Ann Vasc Surg ; 105: 125-131, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38588952

RÉSUMÉ

BACKGROUND: Endovascular aortic surgery is increasingly becoming the standard treatment. Percutaneous access preclosing systems appear to be effective and notably the Proglide (PG). We aimed to prospectively assess the clinical effectiveness of combining ultrasound-guided femoral puncture with ultrasound-guided PG deployment. METHODS: Our single-center study consecutively included patients managed at a tertiary center from May to September 2023, undergoing endovascular aortic surgery. The placement of PG was performed under ultrasound guidance. Preoperative patient characteristics were evaluated using preoperative computed tomography scans. Clinical and technical success were defined, respectively, as the ability to achieve complete hemostasis confirmed by ultrasound 48 hr postprocedure and as the successful placement of a PG under ultrasound guidance contributing to final hemostasis. RESULTS: Twenty patients were included over a 6-month period, totaling 34 common femoral arteries (CFAs). Fourteen were male, with an average age of 72.8 ± 8.2 years. Among the 34 CFA, CFA had diameter of 12.05 ± 2.4 mm and a depth of 38.0 ± 13.4 mm. The mean introducer sheath diameter was 6.2 ± 1.5 mm with a sheath to femoral artery ratio of 0.54 ± 0.18. Successful Proglide placement under ultrasound guidance was achieved in 100% of cases. No PG failure occurred. Clinical and technical success were, respectively, of 95% and 100%. One small pseudoaneurysm was observed at 48 hr treated medically. No CFA access reintervention was required. CONCLUSIONS: The technique of ultrasound-guided PG deployment in aortic surgery is a safe and effective method for achieving hemostasis. It effectively prevents PG failures at a lower cost.


Sujet(s)
Procédures endovasculaires , Artère fémorale , Techniques d'hémostase , Ponctions , Échographie interventionnelle , Humains , Mâle , Procédures endovasculaires/effets indésirables , Procédures endovasculaires/instrumentation , Femelle , Sujet âgé , Artère fémorale/imagerie diagnostique , Artère fémorale/chirurgie , Résultat thérapeutique , Études prospectives , Techniques d'hémostase/instrumentation , Techniques d'hémostase/effets indésirables , Sujet âgé de 80 ans ou plus , Adulte d'âge moyen , Cathétérisme périphérique/effets indésirables , Dispositifs de fermeture vasculaire , Hémostatiques/administration et posologie , Hémostatiques/usage thérapeutique , Facteurs temps
6.
Catheter Cardiovasc Interv ; 103(7): 1125-1137, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38639140

RÉSUMÉ

BACKGROUND: Despite the use of two crossed Perclose ProGlide™ (Abbott Vascular Devices) is the most widespread technique to close the main arterial access in transfemoral transcatheter aortic valve implantation (TF-TAVI), the safest and most effective strategy still remains much debated. AIMS: The aim of the present study was to evaluate the performance of a single Perclose ProGlide suture-mediated closure device to obtain femoral hemostasis after sheathless implantation of self-expanding transcatheter heart valves through their 14 F-equivalent fix delivery systems. METHODS: This prospective observational study included 439 patients undergoing TF-TAVI at the "Montevergine" Clinic of Mercogliano, Italy. All patients underwent hemostasis of the large-bore access using a single Perclose ProGlide with preclose technique, after sheathless implantation of self-expanding transcatheter heart valves through 14 F-equivalent fix delivery systems. A multidetector computed tomography analysis of size, tortuosity, atherosclerotic, and calcification burdens of the ilio-femoral access route was made by a dedicated corelab. Vascular complications (VCs), percutaneous closure device (PCD) failure, and bleedings were adjudicated by a clinical events committee. RESULTS: A total of 81 different VCs were observed in 60 patients (13.7%); among these, 41 (5% of patients) were categorized as major. PCD failure occurred in 14 patients (3.2%). At the logistic regression analysis, no predictors of PCD failure have been identified. CONCLUSION: This registry suggests that the use of a single suture-mediated closure device could be considered a safe and efficient technique to achieve access site hemostasis in patients undergoing TF-TAVI through 14 F-equivalent fix delivery systems.


Sujet(s)
Cathétérisme périphérique , Artère fémorale , Techniques d'hémostase , Ponctions , Techniques de suture , Remplacement valvulaire aortique par cathéter , Dispositifs de fermeture vasculaire , Humains , Artère fémorale/imagerie diagnostique , Mâle , Femelle , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Études prospectives , Sujet âgé de 80 ans ou plus , Résultat thérapeutique , Cathétérisme périphérique/effets indésirables , Sujet âgé , Techniques d'hémostase/instrumentation , Techniques d'hémostase/effets indésirables , Techniques de suture/effets indésirables , Techniques de suture/instrumentation , Facteurs de risque , Facteurs temps , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Italie , Conception d'appareillage , Sténose aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/physiopathologie , Hémorragie/étiologie , Hémorragie/prévention et contrôle
7.
Europace ; 26(5)2024 May 02.
Article de Anglais | MEDLINE | ID: mdl-38647070

RÉSUMÉ

AIMS: Simplified ablation technologies for pulmonary vein isolation (PVI) are increasingly performed worldwide. One of the most common complications following PVI are vascular access-related complications. Lately, venous closure systems (VCSs) were introduced into clinical practice, aiming to reduce the time of bed rest, to increase the patients' comfort, and to reduce vascular access-related complications. The aim of the present study is to compare the safety and efficacy of using a VCS to achieve haemostasis following single-shot PVI to the actual standard of care [figure-of-eight suture and manual compression (MC)]. METHODS AND RESULTS: This is a prospective, multicentre, randomized, controlled, open-label trial performed at three German centres. Patients were randomized 1:1 to undergo haemostasis either by means of VCS (VCS group) or of a figure-of-eight suture and MC (F8 group). The primary efficacy endpoint was the time to ambulation, while the primary safety endpoint was the incidence of major periprocedural adverse events until hospital discharge. A total of 125 patients were randomized. The baseline characteristics were similar between the groups. The VCS group showed a shorter time to ambulation [109.0 (82.0, 160.0) vs. 269.0 (243.8, 340.5) min; P < 0.001], shorter time to haemostasis [1 (1, 2) vs. 5 (2, 10) min; P < 0.001], and shorter time to discharge eligibility [270 (270, 270) vs. 340 (300, 458) min; P < 0.001]. No major vascular access-related complication was reported in either group. A trend towards a lower incidence of minor vascular access-related complications on the day of procedure was observed in the VCS group [7 (11.1%) vs. 15 (24.2%); P = 0.063] as compared to the control group. CONCLUSION: Following AF ablation, the use of a VCS results in a significantly shorter time to ambulation, time to haemostasis, and time to discharge eligibility. No major vascular access-related complications were identified. The use of MC and a figure-of-eight suture showed a trend towards a higher incidence of minor vascular access-related complications.


Sujet(s)
Fibrillation auriculaire , Ablation par cathéter , Veines pulmonaires , Techniques de suture , Humains , Fibrillation auriculaire/chirurgie , Femelle , Mâle , Adulte d'âge moyen , Ablation par cathéter/effets indésirables , Ablation par cathéter/méthodes , Études prospectives , Veines pulmonaires/chirurgie , Techniques de suture/effets indésirables , Sujet âgé , Résultat thérapeutique , Allemagne , Facteurs temps , Dispositifs de fermeture vasculaire , Lever précoce , Techniques d'hémostase/instrumentation
8.
Vasc Endovascular Surg ; 58(6): 588-594, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38477544

RÉSUMÉ

OBJECTIVES: Manual compression (MC) or vascular closure devices (VCDs) are used to achieve hemostasis after percutaneous transluminal angioplasty (PTA). However, limited data on the comparative safety and effectiveness of VCDs vs MC in patients with end-stage renal disease (ESRD) undergoing PTA are available. Accordingly, this study compared the safety and effectiveness of VCD and MC in patients with ESRD undergoing PTA. METHODS: This single-center retrospective cohort study included the data of patients with ESRD undergoing peripheral intervention at Chang Gung Memorial Hospital, Taiwan, from January 1, 2019, to June 30, 2022. The patients were divided into VCD and MC groups. The primary endpoint was a composite of puncture site complications, including acute limb ischemia, marked hematoma, pseudoaneurysm, and puncture site bleeding requiring blood transfusion. RESULTS: We included 264 patients with ESRD undergoing PTA, of whom 60 received a VCD and 204 received MC. The incidence of puncture site complications was 3.3% in the VCD group and 4.4% in the MC group (hazard ratio: .75; 95% confidence interval: .16-3.56 L P = 1.000), indicating no significant between-group difference. CONCLUSION: VCDs and MC had comparable safety and effectiveness for hemostasis in patients with ESRD undergoing peripheral intervention.


Sujet(s)
Techniques d'hémostase , Défaillance rénale chronique , Maladie artérielle périphérique , Ponctions , Dispositifs de fermeture vasculaire , Humains , Mâle , Femelle , Études rétrospectives , Sujet âgé , Techniques d'hémostase/instrumentation , Techniques d'hémostase/effets indésirables , Défaillance rénale chronique/thérapie , Défaillance rénale chronique/diagnostic , Défaillance rénale chronique/complications , Adulte d'âge moyen , Résultat thérapeutique , Maladie artérielle périphérique/thérapie , Maladie artérielle périphérique/imagerie diagnostique , Taïwan , Facteurs de risque , Facteurs temps , Pression , Hémorragie/étiologie , Sujet âgé de 80 ans ou plus , Appréciation des risques
9.
Catheter Cardiovasc Interv ; 103(5): 771-781, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38451155

RÉSUMÉ

BACKGROUND: ProGlide is a percutaneous suture-mediated closure device used in arterial and venous closure following percutaneous intervention. Risk of vascular complications from use, particularly related to failure in hemostasis, or acute vessel closure, remains significant and often related to improper suture deployment. We describe a technique of ultrasound-guided ProGlide deployment in transfemoral transcatheter aortic valve implantation (TF-TAVI). AIMS: The aim of this study is to assess vascular outcomes for ultrasound-guided deployment of ProGlide vascular closure devices in patients undergoing TF-TAVI. METHODS: We collected relevant clinical data of patients undergoing TAVI in a large volume centre. PRIMARY OUTCOME: main access Valve Academic Research Consortium 3 (VARC-3) major vascular complication. SECONDARY OUTCOME: any major/minor VARC-3 vascular complication, its type (bleed or ischemia), and treatment required (medical, percutaneous, or surgical). We performed inverse weighting propensity score analysis to compare the population undergoing ultrasound-guided versus conventional ProGlide deployment for main TAVI access. Ultrasound technique for ProGlide insertion was performed as described below. RESULTS: Five hundred and seventeen patients undergoing TF-TAVI were included. PRIMARY OUTCOME: In 126 (ultrasound-guided) and 391 (conventional ProGlide insertion), 0% versus 1.8% (p < 0.001) had a major VARC-3 vascular complication, respectively. SECONDARY OUTCOME: 0.8% (one minor VARC-3 bleed) vs 4.1% (13 bleeds and three occlusions) had any VARC-3 vascular complication (major and minor) (p < 0.001). Surgical treatment of vascular complication was required in 0.8% versus 1.3% (p = NS). CONCLUSIONS: Ultrasound-guided deployment of ProGlide for vascular closure reduced the risk of major vascular complications in a large population undergoing TAVI.


Sujet(s)
Sténose aortique , Remplacement valvulaire aortique par cathéter , Dispositifs de fermeture vasculaire , Humains , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/complications , Études de cohortes , Artère fémorale/imagerie diagnostique , Artère fémorale/chirurgie , Résultat thérapeutique , Hémorragie/étiologie , Comportement de réduction des risques , Échographie interventionnelle/effets indésirables , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie
10.
Catheter Cardiovasc Interv ; 103(4): 650-659, 2024 03.
Article de Anglais | MEDLINE | ID: mdl-38407552

RÉSUMÉ

BACKGROUND: Vascular complications increase morbidity and mortality in transcatheter aortic valve replacement (TAVR). Data involving suture-based percutaneous vascular closure devices (VCDs) have been extensive. Although promising, data regarding the efficacy and safety of the MANTA VCD (Teleflex) are scarce. We sought to assess the safety and effectiveness of the MANTA device in a real-life unselected cohort of patients undergoing transfemoral-TAVR (TF-TAVR). METHODS: This single-center retrospective observational study included a cohort of consecutive patients with severe aortic stenosis (AS) treated by our team using TAVR between January 2020 to December 2022. The primary outcome measure was access-related major and minor vascular complications according to the Valve Academic Research Consortium (VARC-3) definition criteria. RESULTS: From January 2020 to December 2022, a total of 347 patients underwent TF-TAVR were treated using the MANTA 18 Fr VCD system for vascular closure. Mean age was 82.4 ± 6.1 years (56-98 years). There were no significant differences in preoperative and procedural characteristics between patients with and without VCD-related major vascular complications. Access site-related major and minor vascular complications occurred in 20 of 347 patients (5.7%). Overall, major vascular complications occurred in 5 patients (1.4%) and device failure was seen in 17 patients (4.9%). CONCLUSION: This French real world evaluation of large-bore arteriotomy closure in TF-TAVR indicated that MANTA VCD is a feasible alternative with an acceptable low rate of access-site-related complications.


Sujet(s)
Cathétérisme périphérique , Remplacement valvulaire aortique par cathéter , Dispositifs de fermeture vasculaire , Humains , Sujet âgé , Sujet âgé de 80 ans ou plus , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique , Cathétérisme périphérique/effets indésirables , Ponctions
11.
Cardiovasc Revasc Med ; 62: 60-65, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38184452

RÉSUMÉ

PURPOSE: Mechanical circulatory support (MCS) using a venoarterial extracorporeal membrane oxygenation (VA-ECMO) device or a catheter-type heart pump (Impella) is critical for the rescue of patients with severe cardiogenic shock. However, these MCS devices require large-bore cannula access (14-Fr and larger) at the femoral artery or vein, which often requires surgical decannulation. METHODS: In this retrospective study, we evaluated post-closure method using a percutaneous suture-mediated vascular closure system, Perclose ProGlide/ProStyle (Abbott Vascular, Lake Bluff, IL, Perclose), as an alternative procedure for MCS decannulation. Closure of 83 Impella access sites and 68 VA-ECMO access sites performed using Perclose or surgical method between January 2018 and March 2023 were evaluated. RESULTS: MCS decannulation using Perclose was successfully completed in all access sites without surgical hemostasis. The procedure time of ProGlide was shorter than surgical decannulation for both Impella and VA-ECMO (13 min vs. 50 min; p < 0.001, 21 min vs. 65 min; p < 0.001, respectively). There were no significant differences in the 30-day survival rate and major adverse events by decannulation including arterial dissection requiring endovascular treatment, hemorrhage requiring a large amount of red blood cell transfusion, and access site infection. CONCLUSION: Our results suggest that the post-closure technique using the percutaneous suture-mediated closure system appears to be a safe and effective method for large-bore MCS decannulation.


Sujet(s)
Cathétérisme périphérique , Oxygénation extracorporelle sur oxygénateur à membrane , Dispositifs d'assistance circulatoire , Techniques d'hémostase , Ponctions , Dispositifs de fermeture vasculaire , Humains , Études rétrospectives , Mâle , Femelle , Résultat thérapeutique , Adulte d'âge moyen , Sujet âgé , Oxygénation extracorporelle sur oxygénateur à membrane/effets indésirables , Oxygénation extracorporelle sur oxygénateur à membrane/instrumentation , Facteurs temps , Techniques d'hémostase/instrumentation , Techniques d'hémostase/effets indésirables , Cathétérisme périphérique/effets indésirables , Cathétérisme périphérique/instrumentation , Ablation de dispositif/effets indésirables , Techniques de suture/instrumentation , Techniques de suture/effets indésirables , Artère fémorale , Choc cardiogénique/thérapie , Choc cardiogénique/mortalité , Choc cardiogénique/physiopathologie , Choc cardiogénique/diagnostic , Facteurs de risque , Hémorragie/étiologie , Hémorragie/prévention et contrôle
12.
J Vasc Surg ; 79(3): 569-576, 2024 Mar.
Article de Anglais | MEDLINE | ID: mdl-37923021

RÉSUMÉ

OBJECTIVE: The MANTA device is a plug-based vascular closure device (VCD) designed for large bore femoral arterial access site closure. It showed promising results in transcatheter aortic valve replacement cases. In this study, we report our results and evaluate the MANTA VCD in percutaneous endovascular aortic aneurysm repair (pEVAR). METHODS: All data of consecutive patients who underwent an elective pEVAR between October 2018 and December 2022 were retrospectively reviewed. In all patients at least one common femoral artery was intended to close with the MANTA VCD. Depending on the sheath size, the 14Fr or 18Fr MANTA VCD was used. On the preoperative computed tomography scan, the diameter of the common femoral artery (CFA) was measured and the amount of calcification based on the Peripheral Arterial Calcium Scoring System (PACSS) was scored. Primary outcome was procedural technical success. Procedural technical success was defined as placement of the MANTA closure device resulting in vascular closure with patent CFA, without requiring immediate open or endovascular surgery. The secondary outcomes were access site complications requiring reintervention and all-cause mortality at 30-day follow-up. RESULTS: In total, 152 consecutive patients underwent pEVAR with 291 common femoral artery closure procedures with the Manta VCD. Mean age was 74.1 ± 6.4 years, with a mean body mass index of 27.7 ± 4.4 kg/m2. The mean diameter of the CFA was 10.5 ± 1.9 mm. In 52.6% of the cases, there were no calcification on the preoperative computed tomography scan. The 18Fr and 14Fr Manta VCD were used 169 and 122 times, respectively. The technical success rate was 96.6%. Major vascular complications were reported in 4.5% of the cases, without any death-related events. CONCLUSIONS: This single-center retrospective cohort study analyzed the procedural technical success, major vascular complications and all-cause mortality at 30-day follow-up of the MANTA vascular closure device in 152 pEVAR patients with 291 common femoral artery closure procedures. The technical success rate was 96,6%. Major vascular complications were reported in 4.5% of the cases, without any death related events. We concluded that the MANTA device is a safe and feasible option with a high rate of technical success in patients undergoing pEVAR.


Sujet(s)
Anévrysme de l'aorte , Procédures endovasculaires , Dispositifs de fermeture vasculaire , Humains , Sujet âgé , Sujet âgé de 80 ans ou plus , Procédures endovasculaires/effets indésirables , Techniques d'hémostase , Études rétrospectives , Résultat thérapeutique , Anévrysme de l'aorte/imagerie diagnostique , Anévrysme de l'aorte/chirurgie , Artère fémorale/imagerie diagnostique , Artère fémorale/chirurgie
13.
EuroIntervention ; 20(1): 66-74, 2024 Jan 01.
Article de Anglais | MEDLINE | ID: mdl-37800723

RÉSUMÉ

BACKGROUND: Randomised controlled trials of ultrasound (US)-guided transfemoral access (TFA) for coronary procedures have shown mixed results. AIMS: We aimed to compare US-guided versus non-US-guided TFA from randomised data in an individual participant-level data (IPD) meta-analysis. METHODS: We completed a systematic review and an IPD meta-analysis of all randomised controlled trials comparing US-guided versus non-US-guided TFA for coronary procedures. We performed a one-stage mixed-model meta-analysis using the intention-to-treat population from included trials. The primary outcome was a composite of major vascular complications or major bleeding within 30 days. RESULTS: A total of 2,441 participants (1,208 US-guided, 1,233 non-US-guided) from 4 randomised clinical trials were included. The mean age was 65.5 years, 27.0% were female, and 34.5% underwent a percutaneous coronary intervention. The incidence of major vascular complications or major bleeding (34/1,208 [2.8%] vs 55/1,233 [4.5%]; odds ratio [OR] 0.61, 95% confidence interval [CI]: 0.39-0.94; p=0.026) was lower in the US-guided TFA group. In the prespecified subgroup of participants who received a vascular closure device, those randomised to US-guided TFA experienced a reduction in the primary outcome (2.1% vs 5.6%; OR 0.36, 95% CI: 0.19-0.69), while no benefit for US guidance was observed in the subgroup without vascular closure devices (4.1% vs 3.3%; OR 1.21, 95% CI: 0.65-2.26; interaction p=0.009). CONCLUSIONS: In participants undergoing coronary procedures by TFA, US guidance decreased the composite outcome of major vascular complications or bleeding and may be especially helpful when using vascular closure devices.


Sujet(s)
Intervention coronarienne percutanée , Dispositifs de fermeture vasculaire , Humains , Femelle , Sujet âgé , Mâle , Hémorragie/étiologie , Intervention coronarienne percutanée/effets indésirables , Échographie/effets indésirables , Dispositifs de fermeture vasculaire/effets indésirables , Artère fémorale/imagerie diagnostique , Résultat thérapeutique , Artère radiale
14.
EuroIntervention ; 20(6): e354-e362, 2024 Mar 18.
Article de Anglais | MEDLINE | ID: mdl-37982158

RÉSUMÉ

BACKGROUND: Despite transcatheter aortic valve implantation (TAVI) having become a routine procedure, access site bleeding and vascular complications are still a concern which contribute to procedure-related morbidity and mortality. AIMS: The TAVI-MultiCLOSE study aimed to assess the safety and efficacy of a new vascular closure algorithm for percutaneous large-bore arterial access closure following transfemoral (TF)-TAVI. METHODS: All consecutive TF-TAVI cases in which the MultiCLOSE vascular closure algorithm was used were prospectively included in a multicentre, observational study. This stepwise algorithm entails the reinsertion of a 6-8 Fr sheath (primary access) following the initial preclosure with one or two suture-based vascular closure devices (VCDs). This provides the operator with the opportunity to perform a quick and easy angiographic control and tailor the final vascular closure with either an additional suture- or plug-based VCD, or neither of these. RESULTS: Among 630 patients who underwent TF-TAVI utilising the MultiCLOSE algorithm, complete arterial haemostasis was achieved in 616 patients (98%). VCD failure occurred in 14 patients (2%), treated with either balloon inflation (N=1), covered stent (N=12) or surgical repair (N=1). Overall, this vascular closure approach resulted in a minor and major vascular complication rate of 2.2% and 0.6%, respectively. At 30 days, only one new minor vascular complication (0.2%) was noted. In-hospital and 30-day all-cause mortality rates were 0.2% and 1.0%, respectively. CONCLUSIONS: Use of the MultiCLOSE vascular closure algorithm was demonstrated to contribute to an easy, safe, efficacious and durable vascular closure after TF-TAVI, resulting in a major vascular complication rate of less than 1%.


Sujet(s)
Sténose aortique , Remplacement valvulaire aortique par cathéter , Dispositifs de fermeture vasculaire , Humains , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Artère fémorale/chirurgie , Hémorragie/étiologie , Hémorragie/prévention et contrôle , Techniques d'hémostase/effets indésirables , Remplacement valvulaire aortique par cathéter/méthodes , Résultat thérapeutique , Dispositifs de fermeture vasculaire/effets indésirables
15.
J Vasc Surg ; 79(4): 740-747.e2, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38056701

RÉSUMÉ

BACKGROUND: Percutaneous access and use of vascular closure devices facilitate thoracic endovascular aortic repair (TEVAR) procedures during local anesthesia and allow immediate detection of signs of spinal ischemia. However, the very large bore access (usually ≥22F sheath) associated with TEVAR increases the risk of vascular complications. In this study, we sought to define the safety and feasibility of two percutaneous femoral artery closure devices during TEVAR, in terms of access site vascular complications and major, life-threatening, or fatal bleeding (≥major) within 48 hours. Access site vascular complications were defined as technical failure of vascular closure or later formation of pseudoaneurysm. METHODS: From March 2010 to December 2022, 199 transfemoral TEVAR were performed at Helsinki University Central Hospital, Finland. We retrospectively categorized these into three groups, based on surgeon preference for the access technique and femoral artery closure method: (1) surgical cut-down and vessel closure, n = 85 (42.7%), (2) percutaneous access and vascular closure with suture-based ProGlide, n = 56 (28.1%), or (3) percutaneous access and vascular closure with ultrasound-guided plug-based MANTA, n = 58 (29.1%). The primary outcome measure was technical success of vascular closure and access site vascular complications during index hospitalization. Secondary outcome measures were ≥major bleeding, early mortality, and hospital stay. RESULTS: The technical success rate was 97.6% vs 91.1% vs 93.1% for surgical cut-down, ProGlide, and MANTA, respectively (P = .213). The rate of access site vascular complication was 3.5% vs 8.9% vs 10.3%, respectively (P = .290), with two pseudoaneurysms detected postoperatively and conservatively managed in the MANTA group. The vascular closure method was not associated with increased risk of ≥major bleeding, early mortality, or hospital stay on univariate analysis. Predictors for ≥major bleeding after TEVAR in multivariable analysis were urgent procedure (odds ratio: 2.8, 95% confidence interval: 1.4-5.5; P = .003) and simultaneous aortic branch revascularization (odds ratio: 2.7, 95% confidence interval: 1.3-5.4; P = .008). CONCLUSIONS: In this study, the technical success rates of the percutaneous techniques demonstrated their feasibility during TEVAR. However, the number of access site complications for percutaneous techniques was higher compared with open approach, although the difference was not statistically significant. In the lack of evidence, the safety of the new MANTA plug-based vascular closure for TEVAR warrants further investigation.


Sujet(s)
Cathétérisme périphérique , Procédures endovasculaires , Dispositifs de fermeture vasculaire , Humains , Réparation endovasculaire d'anévrysme , Études rétrospectives , Résultat thérapeutique , Hémorragie/étiologie , Hémorragie/chirurgie , Artère fémorale/imagerie diagnostique , Artère fémorale/chirurgie , Techniques d'hémostase/effets indésirables , Cathétérisme périphérique/effets indésirables
16.
Catheter Cardiovasc Interv ; 103(1): 160-168, 2024 01.
Article de Anglais | MEDLINE | ID: mdl-38059295

RÉSUMÉ

BACKGROUND: New vascular closure devices (VCD) are being introduced for achieving hemostasis after transcatheter aortic valve implantation (TAVI). However, no safety or efficacy data have been published compared to other contemporary VCD. AIM: To compare the safety and efficacy of suture-based Perclose Prostyle as compared to plug-based MANTA device. METHODS: A total of 408 consecutive TAVI patients from two high volume TAVI centers were included in the present study. Patients were grouped according to VCD: Prostyle versus MANTA. Propensity score matching (PSM) and multivariable analysis were utilized to compare clinical endpoints between the two groups. The primary endpoint was any vascular complication (VC) according to VARC-3 criteria. RESULTS: After PSM, a total of 264 patients were analyzed, of them 132 in each group. Overall baseline characteristics of the two groups were comparable. Primary end-point was similar between MANTA as compared to Prostyle (16.7% vs. 15.3% respectively, p = 0.888). The main driver for VC among MANTA group were minor vascular complications (15.2%). Conversely, minor and major VC contributed equally to the primary endpoint among Prostyle group (7.6%) (p = 0.013). No outcome predictors were identified in multivariate analysis. CONCLUSIONS: VCD for transfemoral TAVI using the new-generation Prostyle device or the MANTA device achieved comparable VARC-3 VC rates.


Sujet(s)
Sténose aortique , Cathétérisme périphérique , Remplacement valvulaire aortique par cathéter , Dispositifs de fermeture vasculaire , Humains , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique , Artère fémorale/imagerie diagnostique , Artère fémorale/chirurgie , Cathétérisme périphérique/effets indésirables , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Techniques d'hémostase/effets indésirables
17.
Curr Probl Cardiol ; 49(1 Pt C): 102114, 2024 Jan.
Article de Anglais | MEDLINE | ID: mdl-37802172

RÉSUMÉ

Femoral access site-related bleeding represent a prognostically impactful issue in interventional cardiology. The impact of a combined use of ultrasound guidance for femoral access and vascular closure device deployment for arteriotomy closure in femoral artery procedures on bleeding complications is still largely unknown. A systematic review was conducted on Pubmed (Medline), Cochrane library and Biomed Central databases between March and April 2023. A total of 9 studies have been selected, of namely 4 registries, 4 prospective studies and one randomized clinical trial. A systematic use of US guidance to access femoral artery resulted feasible and not time consuming, reduced venipuncture and increased first attempt success. Combination of US guidance and deployment of VCD's had the capacity to further decrease vascular and bleeding combination, especially in those patients at a higher risk of post-procedural bleeding. Ultrasound can be easily used during closure device deployment to reduce device failure and major vascular complications.


Sujet(s)
Procédures endovasculaires , Dispositifs de fermeture vasculaire , Humains , Artère fémorale , Études prospectives , Études de faisabilité , Dispositifs de fermeture vasculaire/effets indésirables , Hémorragie/étiologie , Résultat thérapeutique , Procédures endovasculaires/effets indésirables , Procédures endovasculaires/méthodes , Essais contrôlés randomisés comme sujet
18.
J Vet Cardiol ; 51: 124-137, 2024 Feb.
Article de Anglais | MEDLINE | ID: mdl-38128418

RÉSUMÉ

INTRODUCTION/OBJECTIVES: Manual compression has been standard of care for maintaining hemostasis after percutaneous endovascular intervention, but can be time-consuming and associated with vascular complications. Alternative closure methods include the figure-of-eight suture (Z-stitch) and vascular closure device (VCD) techniques. We hypothesized that compared to manual compression, Z-stitch and VCD would significantly reduce time-to-hemostasis after transvenous access, and the proportion of dogs with vascular patency would not differ significantly among treatments. ANIMALS: Forty-six client-owned dogs undergoing percutaneous transvenous interventional procedures. MATERIALS AND METHODS: Dogs with vessel diameter <5 mm were randomized to undergo manual compression or Z-stitch, while those with vessel diameter ≥5 mm were randomized to undergo manual compression, Z-stitch, or VCD. Time-to-hemostasis, bleeding scores, presence of vascular patency one day and two to three months post-procedure, and complications were recorded. Data are presented as median (95% confidence interval). RESULTS: In all 46 dogs, the right external jugular vein was used. Time-to-hemostasis was significantly shorter in the Z-stitch (2.1 [1.8-2.9] minutes) compared to VCD (8.6 [6.1-11.8] minutes; P<0.001) and manual compression (10.0 [10.0-20.0] minutes; P<0.001) groups. Time-to-hemostasis was significantly shorter in the VCD vs. manual compression (P=0.027) group. Bleeding scores were significantly greater at 5 and 10 min (P<0.001 and 0.013, respectively) in manual compression, compared to Z-stitch group. There was no difference in the proportion of dogs with vascular patency between groups (P=0.59). CONCLUSIONS: Z-stitch and VCD are effective venous hemostasis methods after percutaneous transvenous intervention, with Z-stitch providing the most rapid time-to-hemostasis. Both Z-stitch and VCD techniques have low complication rates and effectively maintain vascular patency.


Sujet(s)
Maladies des chiens , Techniques d'hémostase , Hémorragie postopératoire , Dispositifs de fermeture vasculaire , Procédures de chirurgie vasculaire , Animaux , Chiens , Maladies des chiens/chirurgie , Artère fémorale/chirurgie , Techniques d'hémostase/effets indésirables , Techniques d'hémostase/médecine vétérinaire , Résultat thérapeutique , Dispositifs de fermeture vasculaire/médecine vétérinaire , Dispositifs de fermeture vasculaire/effets indésirables , Procédures de chirurgie vasculaire/effets indésirables , Procédures de chirurgie vasculaire/instrumentation , Procédures de chirurgie vasculaire/méthodes , Hémorragie postopératoire/prévention et contrôle , Hémorragie postopératoire/médecine vétérinaire
19.
Am J Crit Care ; 32(6): 421-428, 2023 11 01.
Article de Anglais | MEDLINE | ID: mdl-37907375

RÉSUMÉ

BACKGROUND: Bed rest duration following deployment of a vascular closure device after transfemoral left-sided cardiac catheterization is not standardized. Despite research supporting reduced bed rest, many hospitals require prolonged bed rest. Delayed ambulation is associated with back pain, urine retention, difficulty eating, and longer stay. OBJECTIVE: To study length of stay, safety, and opportunity cost savings of reduced bed rest at a large urban hospital. METHODS: A single-site 12-week study of 1-hour bed rest after transfemoral cardiac catheterizations using vascular closure devices. Results were compared with historical controls treated similarly. RESULTS: The standard bed rest group included 295 patients (207 male, 88 female; mean [SD] age, 64.4 [8.6] years). The early ambulation group included 260 patients (188 male, 72 female; mean [SD] age, 64 [9.3] years). The groups had no significant difference in age (t634 = 1.18, P = .21) or sex (χ12=0.2, P = .64). Three patients in the standard bed rest group and 1 in the early ambulation group had hematomas (P = .36). The stay for diagnostic cardiac catheterizations was longer in the standard bed rest group (mean [SD], 220.7 [55.2] minutes) than in the early ambulation group (mean [SD], 182.1 [78.5] minutes; t196 = 4.06; P < .001). Stay for percutaneous coronary interventions was longer in the standard bed rest group (mean [SD], 400.2 [50.8] minutes) than in the early ambulation group (mean [SD], 381.6 [54.7] minutes; t262 = 2.86; P = .005). CONCLUSION: Reduced bed rest was safe, shortened stays, and improved efficiency by creating opportunity cost savings.


Sujet(s)
Dispositifs de fermeture vasculaire , Humains , Mâle , Femelle , Adulte d'âge moyen , Alitement , Cathétérisme cardiaque , Hématome , Lever précoce
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE