Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 1.981
Filtrer
2.
Magn Reson Imaging Clin N Am ; 32(4): 593-613, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322350

RÉSUMÉ

Breast tumors remain a complex and prevalent health burden impacting millions of individuals worldwide. Challenges in treatment arise from the invasive nature of traditional surgery and, in malignancies, the complexity of treating metastatic disease. The development of noninvasive treatment alternatives is critical for improving patient outcomes and quality of life. This review aims to explore the advancements and applications of focused ultrasound (FUS) technology over the past 2 decades. FUS offers a promising noninvasive, nonionizing intervention strategy in breast tumors including primary breast cancer, fibroadenomas, and metastatic breast cancer.


Sujet(s)
Tumeurs du sein , Imagerie interventionnelle par résonance magnétique , Humains , Tumeurs du sein/imagerie diagnostique , Femelle , Imagerie interventionnelle par résonance magnétique/méthodes , Région mammaire/imagerie diagnostique , Ablation par ultrasons focalisés de haute intensité/méthodes , Imagerie par résonance magnétique/méthodes , Échographie interventionnelle/méthodes
3.
Magn Reson Imaging Clin N Am ; 32(4): 615-628, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322351

RÉSUMÉ

Magnetic resonance-guided focused ultrasound surgery (MRgFUS) appears to be an effective and safe treatment for uterine fibroids and adenomyosis, particularly in women who wish to preserve fertility. In abdominal wall endometriosis and painful recurrent gynecologic malignancies, MRgFUS can relieve pain, but more research is needed. There is no widespread reimbursement due to the lack of large prospective or randomized controlled trials comparing MRgFUS with standard therapy.


Sujet(s)
Imagerie interventionnelle par résonance magnétique , Humains , Femelle , Imagerie interventionnelle par résonance magnétique/méthodes , Maladies de l'appareil génital féminin/imagerie diagnostique , Maladies de l'appareil génital féminin/chirurgie , Ablation par ultrasons focalisés de haute intensité/méthodes , Chirurgie assistée par ordinateur/méthodes , Léiomyome/imagerie diagnostique , Léiomyome/chirurgie
4.
Magn Reson Imaging Clin N Am ; 32(4): 629-640, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322352

RÉSUMÉ

Prostate cancer (PCa) is a prevalent malignancy in men, and the management of localized disease has evolved significantly in recent years. Focal therapy, wherein the biopsy confirmed site of tumor with margins is treated leaving the remaining gland intact, has emerged as a promising strategy for treating localized clinically significant PCa, minimizing side effects associated with radical therapies. We present the technical aspects, a summary of the most relevant evidence to date on the performance and safety of this technique, and the characteristic MR imaging findings during treatment, in the early posttreatment period and in the long term.


Sujet(s)
Imagerie interventionnelle par résonance magnétique , Tumeurs de la prostate , Humains , Tumeurs de la prostate/imagerie diagnostique , Tumeurs de la prostate/thérapie , Mâle , Imagerie interventionnelle par résonance magnétique/méthodes , Prostate/imagerie diagnostique , Imagerie par résonance magnétique/méthodes
5.
Magn Reson Imaging Clin N Am ; 32(4): 661-672, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322355

RÉSUMÉ

MR-guided focused ultrasound (FUS) represents a promising alternative for patients with chronic neuropathic who have failed medical management and other treatment options. Early single-center experience with chronic neuropathic pain and trigeminal neuralgia has demonstrated favorable long-term outcomes. Excellent safety profile with low risk of motor and sensory complications and so far anecdotal permanent neurologic deficits make FUS a powerful tool to treat patients who are otherwise hopeless. Neuromodulation may be the most influential factor driving outcomes and studies devised to detect neuroplasticity will be critical to guide such therapies.


Sujet(s)
Douleur chronique , Thalamus , Humains , Douleur chronique/imagerie diagnostique , Douleur chronique/chirurgie , Thalamus/imagerie diagnostique , Thalamus/chirurgie , Imagerie interventionnelle par résonance magnétique/méthodes , Névralgie/imagerie diagnostique , Névralgie/chirurgie , Névralgie/thérapie
6.
Magn Reson Imaging Clin N Am ; 32(4): 651-659, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322354

RÉSUMÉ

Focused ultrasound ablation achieves selective thermal lesioning of the thalamic and basal ganglia targets using real-time MR imaging guidance. It is US Food and Drug Administration-approved to treat essential tremor and Parkinson's disease tremor, fluctuations, and dyskinesias. Patients often seek focused ultrasound treatment because symptom relief is immediate, and hardware implantation is not required. This review summarizes the current and potential future application of focused ultrasound ablation to treat movement disorders. We also discuss the ongoing research optimizing the technique of focused ultrasound ablation to improve long-term efficacy and minimize the risk of side effects.


Sujet(s)
Ablation par ultrasons focalisés de haute intensité , Troubles de la motricité , Humains , Troubles de la motricité/imagerie diagnostique , Ablation par ultrasons focalisés de haute intensité/méthodes , Imagerie interventionnelle par résonance magnétique/méthodes
7.
Magn Reson Imaging Clin N Am ; 32(4): 673-679, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322356

RÉSUMÉ

Malignant gliomas (MGs) are the most common primary brain tumors in adults. Despite recent advances in understanding the biology and potential therapeutic vulnerabilities of MGs, treatment options remain limited as the delivery of drugs is often impeded by the blood-brain barrier (BBB), and safe, complete surgical resection may not always be possible, especially for deep-seated tumors. In this review, the authors highlight emerging applications for MR imaging-guided focused ultrasound (MRgFUS) as a noninvasive treatment modality for MGs. Specifically, the authors discuss MRgFUS's potential role in direct tumor cell killing, opening the BBB, and modulating antitumor immunity.


Sujet(s)
Tumeurs du cerveau , Gliome , Humains , Gliome/imagerie diagnostique , Gliome/thérapie , Tumeurs du cerveau/imagerie diagnostique , Tumeurs du cerveau/thérapie , Imagerie interventionnelle par résonance magnétique/méthodes , Imagerie par résonance magnétique/méthodes , Ablation par ultrasons focalisés de haute intensité/méthodes , Encéphale/imagerie diagnostique
8.
Magn Reson Imaging Clin N Am ; 32(4): 641-650, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322353

RÉSUMÉ

MR-guided focused ultrasound (MRgFUS) has a wide range of musculoskeletal applications. Some indications are well validated, specifically the treatment of painful osseous metastases and osteoid osteoma. Others are only beginning to be studied, such as the treatment of painful facet, sacroiliac, and knee joints. MRgFUS of soft tissue lesions also shows promise, particularly in patients whom alternative modalities are not feasible or may result in significant morbidity. Ongoing and future research will illuminate the full potential for MRgFUS in the treatment of musculoskeletal conditions.


Sujet(s)
Imagerie interventionnelle par résonance magnétique , Maladies ostéomusculaires , Humains , Maladies ostéomusculaires/imagerie diagnostique , Maladies ostéomusculaires/thérapie , Imagerie interventionnelle par résonance magnétique/méthodes , Ablation par ultrasons focalisés de haute intensité/méthodes , Appareil locomoteur/imagerie diagnostique , Tumeurs osseuses/imagerie diagnostique
9.
Magn Reson Imaging Clin N Am ; 32(4): 705-715, 2024 Nov.
Article de Anglais | MEDLINE | ID: mdl-39322359

RÉSUMÉ

MR-guided focused ultrasound (MRgFUS) allows for the incisionless treatment of intracranial lesions in an outpatient setting. While this is currently approved for the surgical treatment of essential tremor and Parkinson's disease, advancements in imaging and ultrasound technology are allowing for the expansion of treatment indications to other intracranial diseases. In addition, these advancements are also making MRgFUS treatments easier, safer, and more efficacious.


Sujet(s)
Imagerie interventionnelle par résonance magnétique , Humains , Imagerie interventionnelle par résonance magnétique/méthodes , Ablation par ultrasons focalisés de haute intensité/méthodes , Encéphalopathies/imagerie diagnostique , Encéphalopathies/chirurgie , Encéphale/imagerie diagnostique , Encéphale/chirurgie , Échographie interventionnelle/méthodes , Chirurgie assistée par ordinateur/méthodes
12.
Arq Neuropsiquiatr ; 82(8): 1-7, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-39187258

RÉSUMÉ

BACKGROUND: The magnetic resonance imaging-guided focused ultrasound (MRgFUS) has emerged as an innovative treatment for patients with medically refractory essential tremor (ET). OBJECTIVE: This retrospective observational study aims to present the results of the first five patients with medically refractory ET who underwent MRgFUS treatment at this pioneering medical unit in Portugal. METHODS: We conducted a retrospective chart review for the first five patients who underwent unilateral MRgFUS thalamotomy of the ventral intermediate (Vim) nucleus to treat medically refractory ET at our medical unit. RESULTS: The mean patient age was 65.4 (26-84) years, and 60% were male. All patients had a family history of ET. The mean duration of disease was 17.4 years (range 10-24 years), and their dominant hand was the right. According to personal preference, the thalamotomy was performed on the left side in four patients, and on the right side in one. The MRgFUS thalamotomy led to significant improvements in both the clinical rating scale for tremor (CRST) score, by 62%, and the CRST composite score for the treated hand, by 73%. All patients experienced improvements in functionality and quality of life, by 52%. No severe adverse events were observed, and those that did occur during and following the procedure were mild and transient. CONCLUSION: The initial results from Portugal's first MRgFUS medical unit indicate promising outcomes, with improvement in quality of life, as well as mild and temporary adverse events These findings contribute to the growing body of literature supporting the efficacy and safety of MRgFUS as a viable treatment option for patients with medication-resistant ET.


ANTECEDENTES: A talomotomia por ultrassons focados - guiada por imagem de ressonância magnética (MRgFUS) surgiu recentemente como um tratamento inovador para pacientes com tremor essencial (TE) refratário ao tratamento médico. OBJETIVO: Este estudo observacional retrospectivo tem como objetivo apresentar os resultados dos primeiros cinco pacientes com TE refratário à medicação submetidos ao tratamento com MRgFUS numa unidade médica pioneira em Portugal. MéTODOS: Realizamos uma revisão retrospectiva dos dados clínicos dos cinco primeiros pacientes submetidos a talamotomia MRgFUS unilateral do núcleo ventral intermédio (Vim) para tratamento do TE medicamente refratário em nossa unidade médica. RESULTADOS: A idade média dos pacientes era de 65,4 (26­84) anos, e 60% eram do sexo masculino. Todos os pacientes tinham história familiar de TE. A duração média da doença foi de 17,4 anos, e todos eram destros. De acordo com a preferência individual, em 4 pacientes, a talamotomia foi realizada no lado esquerdo, e em um, no lado direito. A talamotomia por MRgFUS levou a melhorias significativas tanto na pontuação da escala de classificação clínica para tremor (CRST), de 62%, e na pontuação composta da CRST para a mão tratada, de 73%. Todos os pacientes apresentaram melhorias na funcionalidade e na qualidade de vida, de 52%. Não foram observados efeitos adversos graves e os que ocorreram durante e após o procedimento foram ligeiros e transitórios. CONCLUSãO: Os resultados iniciais da primeira unidade médica MRgFUS de Portugal indicam melhorias na qualidade de vida dos pacientes, com efeitos adversos ligeiros e transitórios. Estes dados reforçam a evidência crescente sobre a eficácia e segurança da talamotomia por MRgFUS como opção viável para pacientes com TE resistente à medicação.


Sujet(s)
Tremblement essentiel , Humains , Mâle , Tremblement essentiel/chirurgie , Tremblement essentiel/imagerie diagnostique , Études rétrospectives , Sujet âgé , Adulte d'âge moyen , Femelle , Adulte , Sujet âgé de 80 ans ou plus , Résultat thérapeutique , Portugal , Thalamus/chirurgie , Thalamus/imagerie diagnostique , Imagerie interventionnelle par résonance magnétique , Imagerie par résonance magnétique , Reproductibilité des résultats , Échographie interventionnelle/méthodes
13.
Radiol Med ; 129(9): 1412-1423, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-39154318

RÉSUMÉ

PURPOSE: To investigate whether MRI-guided transrectal laser ablation is safe and effective for the treatment of lower urinary tract symptoms caused by BPH. MATERIALS AND METHODS: This single-center retrospective cohort study evaluated men who underwent MRI-guided transrectal laser ablation for BPH between February 2017 and July 2021. Age, prostate-specific antigen, prostate volume, prior surgical BPH treatments if any, International Prostate Symptom Score (IPSS) and Sexual Health Inventory of Men (SHIM) were collected. The primary outcome measures assessed were change in IPSS and SHIM 6, 12 and 24 months after laser ablation and adverse events. RESULTS: Fifty-two patients were included, having completed at least one follow-up survey. The mean patient age was 62.9 ± 5.7 years, and mean prostate volume was 80.2 ± 39.2 cc. Eighteen patients (34.6%) had received a prior BPH treatment. The IPSS scores dropped an average of 16.7 ± 7.0 (p < 0.001), 16.9 ± 7.5 (p < 0.001) and 17.1 ± 7.2 (p < 0.001) points from baseline at 6, 12 and 24 months, respectively. There was no statistically significant difference in IPSS score drop between patients who had received a prior BPH procedure and those who had not (p = 0.628). The SHIM scores showed a statistically insignificant increase at all time points. Nineteen patients (36.5%) reported a complication. There were 12 grade II complications (23%) and seven grade I complications (13.5%). There were no grade III or higher complications. CONCLUSION: Transrectal MRI-guided focal laser ablation is safe and effective for the treatment of lower urinary tract symptoms caused by BPH, with a significant improvement in symptom severity after 2 years.


Sujet(s)
Thérapie laser , Hyperplasie de la prostate , Humains , Mâle , Hyperplasie de la prostate/chirurgie , Hyperplasie de la prostate/imagerie diagnostique , Études rétrospectives , Adulte d'âge moyen , Thérapie laser/méthodes , Sujet âgé , Résultat thérapeutique , Symptômes de l'appareil urinaire inférieur/étiologie , Symptômes de l'appareil urinaire inférieur/chirurgie , Imagerie interventionnelle par résonance magnétique/méthodes , Imagerie par résonance magnétique/méthodes
14.
Int Braz J Urol ; 50(5): 616-628, 2024.
Article de Anglais | MEDLINE | ID: mdl-39106117

RÉSUMÉ

PURPOSE: To compare transperineal (TP) vs transrectal (TR) magnetic resonance imaging (MRI) and transrectal ultrasound (TRUS) fusion-guided prostate biopsy (PBx) in a large, ethnically diverse and multiracial cohort. MATERIALS AND METHODS: Consecutive patients who underwent multiparametric (mp) MRI followed by TP or TR TRUS-fusion guided PBx, were identified from a prospective database (IRB #HS-13-00663). All patients underwent mpMRI followed by 12-14 core systematic PBx. A minimum of two additional target-biopsy cores were taken per PIRADS≥3 lesion. The endpoint was the detection of clinically significant prostate cancer (CSPCa; Grade Group, GG≥2). Statistical significance was defined as p<0.05. RESULTS: A total of 1491 patients met inclusion criteria, with 480 undergoing TP and 1011 TR PBx. Overall, 11% of patients were Asians, 5% African Americans, 14% Hispanic, 14% Others, and 56% White, similar between TP and TR (p=0.4). For PIRADS 3-5, the TP PBx CSPCa detection was significantly higher (61% vs 54%, p=0.03) than TR PBx, but not for PIRADS 1-2 (13% vs 13%, p=1.0). After adjusting for confounders on multivariable analysis, Black race, but not the PBx approach (TP vs TR), was an independent predictor of CSPCa detection. The median maximum cancer core length (11 vs 8mm; p<0.001) and percent (80% vs 60%; p<0.001) were greater for TP PBx even after adjusting for confounders. CONCLUSIONS: In a large and diverse cohort, Black race, but not the biopsy approach, was an independent predictor for CSPCa detection. TP and TR PBx yielded similar CSPCa detection rates; however the TP PBx was histologically more informative.


Sujet(s)
Biopsie guidée par l'image , Prostate , Tumeurs de la prostate , Échographie interventionnelle , Humains , Mâle , Tumeurs de la prostate/anatomopathologie , Tumeurs de la prostate/imagerie diagnostique , Biopsie guidée par l'image/méthodes , Adulte d'âge moyen , Sujet âgé , Échographie interventionnelle/méthodes , Prostate/anatomopathologie , Prostate/imagerie diagnostique , Périnée , Imagerie interventionnelle par résonance magnétique/méthodes , Grading des tumeurs , Imagerie par résonance magnétique multiparamétrique/méthodes , Reproductibilité des résultats
15.
Radiol Imaging Cancer ; 6(5): e240009, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-39212524

RÉSUMÉ

Purpose To compare diffusion-weighted imaging (DWI) with thermal dosimetry as a noncontrast method to predict ablation margins in individuals with prostate cancer treated with MRI-guided focused ultrasound (MRgFUS) ablation. Materials and Methods This secondary analysis of a prospective trial (ClinicalTrials.gov no. NCT01657942) included 17 participants (mean age, 64 years ± 6 [SD]; all male) who were treated for prostate cancer using MRgFUS in whom DWI was performed immediately after treatment. Ablation contours from computed thermal dosimetry and DWI as drawn by two blinded radiologists were compared against the reference standard of ablation assessment, posttreatment contrast-enhanced nonperfused volume (NPV) contours. The ability of each method to predict the ablation zone was analyzed quantitively using Dice similarity coefficients (DSCs) and mean Hausdorff distances (mHDs). Results DWI revealed a hyperintense rim at the margin of the ablation zone. While DWI accurately helped predict treatment margins, thermal dose contours underestimated the extent of the ablation zone compared with the T1-weighted NPV imaging reference standard. Quantitatively, contour assessment between methods showed that DWI-drawn contours matched postcontrast NPV contours (mean DSC = 0.84 ± 0.05 for DWI, mHD = 0.27 mm ± 0.13) better than the thermal dose contours did (mean DSC = 0.64 ± 0.12, mHD = 1.53 mm ± 1.20) (P < .001). Conclusion This study demonstrates that DWI, which can visualize the ablation zone directly, is a promising noncontrast method that is robust to treatment-related bulk motion compared with thermal dosimetry and correlates better than thermal dosimetry with the reference standard T1-weighted NPV. Keywords: Interventional-Body, Ultrasound-High-Intensity Focused (HIFU), Genital/Reproductive, Prostate, Oncology, Imaging Sequences, MRI-guided Focused Ultrasound, MR Thermometry, Diffusionweighted Imaging, Prostate Cancer ClinicalTrials.gov Identifier no. NCT01657942 Supplemental material is available for this article. © RSNA, 2024.


Sujet(s)
Imagerie par résonance magnétique de diffusion , Tumeurs de la prostate , Sujet âgé , Humains , Mâle , Adulte d'âge moyen , Imagerie par résonance magnétique de diffusion/méthodes , Ablation par ultrasons focalisés de haute intensité/méthodes , Imagerie interventionnelle par résonance magnétique/méthodes , Études prospectives , Prostate/imagerie diagnostique , Prostate/chirurgie , Tumeurs de la prostate/imagerie diagnostique , Tumeurs de la prostate/chirurgie
16.
Curr Cardiol Rep ; 26(9): 903-910, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-39023800

RÉSUMÉ

PURPOSE OF REVIEW: Cardiovascular magnetic resonance (CMR) imaging excels in providing detailed three-dimensional anatomical information together with excellent soft tissue contrast and has already become a valuable tool for diagnostic evaluation, electrophysiological procedure (EP) planning, and therapeutical stratification of atrial or ventricular rhythm disorders. CMR-based identification of ablation targets may significantly impact existing concepts of interventional electrophysiology. In order to exploit the inherent advantages of CMR imaging to the fullest, CMR-guided ablation procedures (EP-CMR) are justly considered the ultimate goal. RECENT FINDINGS: Electrophysiological cardiovascular magnetic resonance (EP-CMR) interventional procedures have more recently been introduced to the CMR armamentarium: in a single-center series of 30 patients, an EP-CMR guided ablation success of 93% has been reported, which is comparable to conventional ablation outcomes for typical atrial flutter and procedure and ablation time were also reported to be comparable. However, moving on from already established workflows for the ablation of typical atrial flutter in the interventional CMR environment to treatment of more complex ventricular arrhythmias calls for technical advances regarding development of catheters, sheaths and CMR-compatible defibrillator equipment. CMR imaging has already become an important diagnostic tool in the standard clinical assessment of cardiac arrhythmias. Previous studies have demonstrated the feasibility and safety of performing electrophysiological interventional procedures within the CMR environment and fully CMR-guided ablation of typical atrial flutter can be implemented as a routine procedure in experienced centers. Building upon established workflows, the market release of new, CMR-compatible interventional devices may finally enable targeting ventricular arrhythmias.


Sujet(s)
Ablation par cathéter , Imagerie interventionnelle par résonance magnétique , Humains , Ablation par cathéter/méthodes , Imagerie interventionnelle par résonance magnétique/méthodes , Techniques électrophysiologiques cardiaques/méthodes , Troubles du rythme cardiaque/imagerie diagnostique , Troubles du rythme cardiaque/thérapie
17.
Clin Breast Cancer ; 24(7): 597-603, 2024 Oct.
Article de Anglais | MEDLINE | ID: mdl-39013683

RÉSUMÉ

INTRODUCTION: MRI-guided biopsy is the standard of care for breast imaging findings seen only by MRI. Although a non-zero false-negative rate of MRI-guided breast biopsy has been reported by multiple studies, there are varied practice patterns for imaging follow-up after a benign concordant MRI guided biopsy. This study assessed the outcomes of benign concordant MRI-guided biopsies at a single institution. PATIENTS AND METHODS: This IRB-approved, retrospective study included patients with MRI-guided biopsies of breast lesions from November 1, 2014, to August 31, 2020. Only image-concordant breast lesions with benign histopathology and those follow up with MRI imaging or excision were included in the study. RESULTS: Out of 275 lesions in 216 patients that met the inclusion criteria, 274 lesions were followed with MRI (range, 5-79 months; average, 25.5 months) and showed benign or stable features upon follow-up. One out of 275 lesions (0.4%), a 6 mm focal nonmass enhancement, was ultimately found to represent malignancy after initial MRI-guided biopsy yielded fibrocystic changes. The lesion was stable at a 6-month follow-up MRI but increased in size at 18 months. Repeat biopsy by ultrasound guidance yielded invasive ductal carcinoma (IDC) and ductal carcinoma in situ (DCIS). CONCLUSION: Breast MRI-guided biopsy has a low false-negative rate. Our single malignancy from a total of 275 lesions gives a false negative rate of 0.4%. This data also supports a longer follow-up interval than the commonly performed 6-month follow-up, in order to assess for interval change.


Sujet(s)
Tumeurs du sein , Biopsie guidée par l'image , Imagerie par résonance magnétique , Humains , Femelle , Études rétrospectives , Biopsie guidée par l'image/méthodes , Tumeurs du sein/anatomopathologie , Tumeurs du sein/imagerie diagnostique , Adulte d'âge moyen , Adulte , Sujet âgé , Imagerie par résonance magnétique/méthodes , Région mammaire/anatomopathologie , Région mammaire/imagerie diagnostique , Région mammaire/chirurgie , Imagerie interventionnelle par résonance magnétique/méthodes , Études de suivi , Sujet âgé de 80 ans ou plus , Jeune adulte , Faux négatifs
18.
Eur J Radiol ; 178: 111602, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-38991285

RÉSUMÉ

INTRODUCTION: The non-perfused volume divided by total fibroid load (NPV/TFL) is a predictive outcome parameter for MRI-guided high-intensity focused ultrasound (MR-HIFU) treatments of uterine fibroids, which is related to long-term symptom relief. In current clinical practice, the MR-HIFU outcome parameters are typically determined by visual inspection, so an automated computer-aided method could facilitate objective outcome quantification. The objective of this study was to develop and evaluate a deep learning-based segmentation algorithm for volume measurements of the uterus, uterine fibroids, and NPVs in MRI in order to automatically quantify the NPV/TFL. MATERIALS AND METHODS: A segmentation pipeline was developed and evaluated using expert manual segmentations of MRI scans of 115 uterine fibroid patients, screened for and/or undergoing MR-HIFU treatment. The pipeline contained three separate neural networks, one per target structure. The first step in the pipeline was uterus segmentation from contrast-enhanced (CE)-T1w scans. This segmentation was subsequently used to remove non-uterus background tissue for NPV and fibroid segmentation. In the following step, NPVs were segmented from uterus-only CE-T1w scans. Finally, fibroids were segmented from uterus-only T2w scans. The segmentations were used to calculate the volume for each structure. Reliability and agreement between manual and automatic segmentations, volumes, and NPV/TFLs were assessed. RESULTS: For treatment scans, the Dice similarity coefficients (DSC) between the manually and automatically obtained segmentations were 0.90 (uterus), 0.84 (NPV) and 0.74 (fibroid). Intraclass correlation coefficients (ICC) were 1.00 [0.99, 1.00] (uterus), 0.99 [0.98, 1.00] (NPV) and 0.98 [0.95, 0.99] (fibroid) between manually and automatically derived volumes. For manually and automatically derived NPV/TFLs, the mean difference was 5% [-41%, 51%] (ICC: 0.66 [0.32, 0.85]). CONCLUSION: The algorithm presented in this study automatically calculates uterus volume, fibroid load, and NPVs, which could lead to more objective outcome quantification after MR-HIFU treatments of uterine fibroids in comparison to visual inspection. When robustness has been ascertained in a future study, this tool may eventually be employed in clinical practice to automatically measure the NPV/TFL after MR-HIFU procedures of uterine fibroids.


Sujet(s)
Apprentissage profond , Ablation par ultrasons focalisés de haute intensité , Léiomyome , Tumeurs de l'utérus , Humains , Femelle , Léiomyome/imagerie diagnostique , Léiomyome/thérapie , Tumeurs de l'utérus/imagerie diagnostique , Tumeurs de l'utérus/thérapie , Ablation par ultrasons focalisés de haute intensité/méthodes , Imagerie par résonance magnétique/méthodes , Adulte , Reproductibilité des résultats , Charge tumorale , Adulte d'âge moyen , Résultat thérapeutique , Imagerie interventionnelle par résonance magnétique/méthodes , Utérus/imagerie diagnostique , Utérus/anatomopathologie
19.
Cancer Imaging ; 24(1): 81, 2024 Jul 01.
Article de Anglais | MEDLINE | ID: mdl-38956721

RÉSUMÉ

BACKGROUND: Numerous studies have shown that magnetic resonance imaging (MRI)-targeted biopsy approaches are superior to traditional systematic transrectal ultrasound guided biopsy (TRUS-Bx). The optimal number of biopsy cores to be obtained per lesion identified on multiparametric MRI (mpMRI) images, however, remains a matter of debate. The aim of this study was to evaluate the incremental value of additional biopsy cores in an MRI-targeted "in-bore"-biopsy (MRI-Bx) setting. PATIENTS AND METHODS: Two hundred and forty-five patients, who underwent MRI-Bx between June 2014 and September 2021, were included in this retrospective single-center analysis. All lesions were biopsied with at least five biopsy cores and cumulative detection rates for any cancer (PCa) as well as detection rates of clinically significant cancers (csPCa) were calculated for each sequentially labeled biopsy core. The cumulative per-core detection rates are presented as whole numbers and as proportion of the maximum detection rate reached, when all biopsy cores were considered. CsPCa was defined as Gleason Score (GS) ≥ 7 (3 + 4). RESULTS: One hundred and thirty-two of 245 Patients (53.9%) were diagnosed with prostate cancer and csPCa was found in 64 (26.1%) patients. The first biopsy core revealed csPCa/ PCa in 76.6% (49/64)/ 81.8% (108/132) of cases. The second, third and fourth core found csPCa/ PCa not detected by previous cores in 10.9% (7/64)/ 8.3% (11/132), 7.8% (5/64)/ 5.3% (7/132) and 3.1% (2/64)/ 3% (4/132) of cases, respectively. Obtaining one or more cores beyond the fourth biopsy core resulted in an increase in detection rate of 1.6% (1/64)/ 1.5% (2/132). CONCLUSION: We found that obtaining five cores per lesion maximized detection rates. If, however, future research should establish a clear link between the incidence of serious complications and the number of biopsy cores obtained, a three-core biopsy might suffice as our results suggest that about 95% of all csPCa are detected by the first three cores.


Sujet(s)
Biopsie guidée par l'image , Tumeurs de la prostate , Humains , Mâle , Tumeurs de la prostate/anatomopathologie , Tumeurs de la prostate/imagerie diagnostique , Études rétrospectives , Sujet âgé , Biopsie guidée par l'image/méthodes , Adulte d'âge moyen , Prostate/anatomopathologie , Prostate/imagerie diagnostique , Imagerie par résonance magnétique/méthodes , Biopsie au trocart/méthodes , Grading des tumeurs , Imagerie interventionnelle par résonance magnétique/méthodes , Imagerie par résonance magnétique multiparamétrique/méthodes
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE