Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 315
Filtrer
1.
Odontology ; 112(1): 138-147, 2024 Jan.
Article de Anglais | MEDLINE | ID: mdl-37097420

RÉSUMÉ

The aim of this study was to assess the fracture behavior of molar teeth restored with MOD inlays made of experimental short fiber-reinforced CAD/CAM composite block (SFRC CAD) before and after cyclic fatigue aging. Standardized MOD cavities were prepared on 60 intact mandibular molars. Three groups of CAD/CAM made inlay restorations (Cerasmart 270, Enamic, and SFRC CAD) were fabricated (n = 20/group). All restorations were luted with self-adhesive dual-cure resin cement (G-Cem One). Half of restored teeth per each group (n = 10) were quasi-statically loaded until fracture without aging. The other half underwent cyclic fatigue aging for 500,000 cycles (Fmax = 150 N) before being loaded quasi-statically until fracture. Then, the fracture type was visually inspected. The microstructure and elemental content of CAD/CAM materials were assessed using SEM and EDS. Two-way analysis of variance (ANOVA) was used to statistically examine the data, and it was followed by the Tukey HSD test (α = 0.05). ANOVA demonstrated that both material type and aging had a significant effect (p < 0.05) on the load-bearing capacity values of the restorations. Teeth restored with SFRC CAD showed significantly the highest (p < 0.05) load-bearing capacity (2535 ± 830 N) after fatigue aging among all groups. SEM images showed the ability of short fibers in SFRC CAD composite to redirect and hinder crack propagation. With regard to fracture mode, Enamic group revealed 85% of catastrophic failure (vs. 45% and 10% for Cerasmart 270 and SFRC CAD, respectively). Large MOD cavities on molar teeth were most favorably restored with SFRC CAD inlays, yielding the highest load-bearing capacity and more restorable failures.


Sujet(s)
Caries dentaires , Inlays , Humains , Inlays/méthodes , Résines composites/composition chimique , Analyse du stress dentaire , Molaire , Conception assistée par ordinateur , Test de matériaux
2.
Shanghai Kou Qiang Yi Xue ; 31(3): 300-304, 2022 Jun.
Article de Chinois | MEDLINE | ID: mdl-36204961

RÉSUMÉ

PURPOSE: To investigate the short-term and long-term effects of all-ceramic onlay on restoration of premolars and its influence on dental function. METHODS: Ninety-five premolars receiving root canal treatment in People's Hospital of Peking University from January 2017 to January 2018 were enrolled, and randomly divided into two groups based on different repairing methods. Patients in the control group (n=47) received full crown restoration, while patients in the experimental group(n=48) received all-ceramic onlay restoration. The success, survival and failure rates of the teeth were compared. The United States Public Health Service(USPHS) and occlusal function of the prosthesis were compared 6, 12 and 36 months after treatment. The data were processed using SPSS 19.0 software package. RESULTS: The success and survival rate of the experimental group were higher than those of the control group, but without significant difference (P>0.05). The morphology, marginal integrity, marginal coloration, surface texture, secondary caries, gingival health and proximal contacts showed no significant difference between the two groups 12 months after treatment(P>0.05). Thirty-six months after treatment, the marginal integrity, marginal coloration and surface texture showed no significant difference between the two groups (P>0.05), while the morphology, secondary caries, gingival health and proximal contacts were significantly better in the experimental group than in the control group (P<0.05). The occlusal function between the affected side and contralateral side of both groups showed no significant difference 6, 12 and 36 months after treatment(P>0.05). CONCLUSIONS: All-ceramic onlay restoration of premolars has high success and survival rate, and good short-term and long-term restoration effect, which is beneficial to improve the occlusal function of the affected teeth.


Sujet(s)
Porcelaine dentaire , Inlays , Prémolaire , Céramiques , Échec de restauration dentaire , Humains , Inlays/méthodes , Traitement de canal radiculaire
3.
Oral Health Prev Dent ; 20(1): 271-278, 2022 Jun 28.
Article de Anglais | MEDLINE | ID: mdl-35762363

RÉSUMÉ

PURPOSE: Conservative restorations of endodontically treated premolars have yielded mixed results. The present study aimed to compare fracture resistance of endodontically treated premolars with Class II mesial-occlusal cavity preparations, restored with either Smart Dentin Replacement (SDR; Dentsply Sirona) material, Biodentine (Septodont) or ceramic inlays. MATERIALS AND METHODS: Thirty-two extracted premolars were randomly divided into four equal groups (n = 8): Group 1 served as a control group with teeth left intact; teeth in the remaining three groups received root canal treatment followed by a mesio-occlusal cavity preparation. These crowns were restored with: Biodentine in group 2, SDR in group 3 and ceramic inlays in group 4. A computer-controlled Instron universal testing machine subjected all specimens to compressive load until failure. Force at failure and fracture mode (above or below the cementoenamel junction) were recorded. The data were analysed using Fisher's exact test and one-way ANOVA followed by the post-hoc Tukey's test. Statistical significance was set at p < 0.05. RESULTS: The lowest mean load at failure was recorded for the inlay group. Loads at failure were statistically significantly higher for teeth restored with Biodentine than with SDR (p = 0.012) and ceramic inlays (p = 0.007). There were no statistically significant differences between the groups in terms of fracture mode (p = 0.440). CONCLUSION: Endodontically treated premolars with mesial-occlusal cavity preparation restored with Biodentine were more resistant to fracture than those restored with either SDR or ceramic inlays. Biodentine may prove a promising material to restore endodontically treated teeth with one missing proximal wall.


Sujet(s)
Fractures dentaires , Dent dévitalisée , Prémolaire , Résines composites , Porcelaine dentaire , Dentine , Humains , Inlays/méthodes , Test de matériaux , Fractures dentaires/prévention et contrôle , Dent dévitalisée/thérapie
4.
Swiss Dent J ; 132(7-8): 482-489, 2022 07 11.
Article de Anglais | MEDLINE | ID: mdl-35477221

RÉSUMÉ

This study aimed to evaluate the effect of immediate dentin sealing (IDS) on the fracture strength of ceramic onlays when compared with delayed dentin sealing (DDS). Twenty extracted human maxillary premolars were randomly divided into 2 groups according to the dentin sealing technique (n=10). A standardized mesio-occlusal-distal cavity was prepared with reduction of the palatal cusp. The dentin surfaces of the IDS group were immediately sealed after finishing the preparation (before taking impressions, temporization, and 14-day storage at 37°C) using a bonding system (ALL-BOND 3®, ALL-BOND 3® RESIN) and flowable composite (Te-Econom Flow). Impressions were made and temporary restorations were fabricated using PRO-V FILL®. The wax patterns were milled and the onlays were fabricated by heat-pressing technique (IPS e.max Press). After bonding the final restorations with resin cement (Variolink N), the specimens were thermocycled. Fracture strength was measured using a universal testing machine (Testometric M350-10KN) at 1 mm/min until failure occurred. Student's t-test was used to evaluate the results of the fracture strength test. The failure mode was examined using a stereomicroscope. The mean fracture strength in the IDS group (1335 ± 335 N) was statistically significantly higher than that for the DDS group (931 ± 274 N) (p < 0.05). Fracture of the restoration with a small portion of the tooth was the most frequent mode of failure. Within the limitation of this in vitro study, there was an improvement in the fracture strength of ceramic onlays with the use of IDS. However, the ceramic onlays were strong enough to withstand the physiological mastication force in both groups.


Sujet(s)
Collage dentaire , Inlays , Céramiques , Collage dentaire/méthodes , Porcelaine dentaire , Analyse du stress dentaire , Dentine , Résistance à la flexion , Humains , Inlays/méthodes , Test de matériaux , Céments résine
5.
São José dos Campos; s.n; 2021. 89 p. il., graf., tab..
Thèse de Portugais | BBO - Ondontologie | ID: biblio-1255009

RÉSUMÉ

Este estudo avaliou o efeito da elevação da margem gengival (DME) e dos materiais restauradores (cerâmica vítrea reforçada por leucita [C] vs. resina composta indireta [R]) no comportamento de fadiga e distribuição de tensão de molares superiores com margens proximais com 2 mm de profundidade restauradas com inlays mesio-ocluso-distal (MOD). Para isso, 52 terceiros molares humanos extraídos foram distribuídos aleatoriamente em quatro grupos (n = 13): C; DME + C; R; e DME + R. Restaurações do tipo inlay foram confeccionados no CAD-CAM e cimentadas adesivamente em todos os dentes. O comportamento em fadiga foi avaliado com o ensaio de vida acelerada stepwise stress (10.000 ciclos/step; step=50 N; 20 Hz; carga inicial=200 N). As cargas e o número de ciclos de falha em fadiga foram analisados com ANOVA de 2 fatores e teste de Tukey (p <0,05), também foram realizados gráficos de sobrevivência de Kaplan-Meier. A distribuição de tensões foi avaliada utilizando a análise por elementos finitos. Os modelos foram considerados isotrópicos, lineares, homogêneos e apresentaram contatos colados. Uma carga axial (400 N) foi aplicada à superfície oclusal. A distribuição de tensões foi analisada com o critério de tensão principal máxima. Para o comportamento em fadiga, não houve diferença para o fator DME (p> 0,05). Para o fator material restaurador, a carga e o número de ciclos para falha foram estatisticamente maiores nos grupos R (p <0,05). A análise por elementos finitos mostrou que os inlays de resina composta concentraram mais tensões na estrutura do dente, enquanto os inlays de cerâmica concentraram mais tensões na restauração. Falhas não reparáveis foram mais frequentes nos grupos de inlays de resina composta. Foi possível concluir que a DME não foi prejudicial para o comportamento em fadiga e na distribuição de tensão. As inlays de resina composta foram mais resistentes ao teste de fadiga, embora o modo de falha tenha sido mais agressivo(AU)


Objectives: This study evaluated the effect of deep margin elevation (DME) and restorative materials (leucite-reinforced glass-ceramics [C] vs. indirect resin composite [R]) on the fatigue behavior and stress distribution of upper molars with 2-mm deep proximal margins restored with MOD-inlay. Methods: Fiftytwo extracted human third molars were randomly assigned into four groups (n=13): C; DME+C; R; and DME+R. Inlays were fabricated in CAD-CAM and bonded to all teeth. The fatigue behavior was assessed with the stepwise stress test (10,000 cycles/step; step=50N; 20 Hz; initial load=200 N). Fatigue failure loads and number of cycles were analyzed with 2-way ANOVA and Tukey's test (p<0.05) and Kaplan-Meier survival plots. The stress distribution was assessed with finite element analysis. The models were considered isotropic, linear, homogeneous, and presented bonded contacts. A tripod axial load (400 N) was applied to the occlusal surface. The stress distribution was analyzed with the maximum principal stress criterion. Results: For fatigue, there was no difference for DME factor (p>.05). For the material factor, the load and number of cycles for failure were statistically higher in the R groups (p<.05). The finite element analysis showed that resin composite inlays concentrated more stress in the tooth structure, while ceramic inlays concentrated more stress in the restoration. Non-reparable failures were more frequent in the resin composite inlays groups. Conclusions: DME was not negative for fatigue and biomechanical behaviors. Resin composite inlays were more resistant to the fatigue test, although the failure mode was more aggressive(AU)


Sujet(s)
Échec de restauration dentaire/classification , Résines composites/administration et posologie , Analyse des éléments finis/statistiques et données numériques , Porcelaine dentaire/synthèse chimique , Inlays/méthodes
6.
Scanning ; 2019: 1289570, 2019.
Article de Anglais | MEDLINE | ID: mdl-31741697

RÉSUMÉ

The aim of this study was to evaluate the accuracy of two intraoral scanners used in the dental office. A molar fixed in a typodont was prepared for a ceramic onlay. The preparation was scanned using a high-resolution scanner (reference scanner) and saved as stereolithography (STL) format. The prepared resin molar was scanned again using the intraoral scanners, and all the scans were saved as well in STL format. All STL files were compared using metrology software (Geomagic Control X). Overlapping the meshes allowed the assessment of the scans in terms of trueness and precision. Based on the results of this study, the differences of trueness and precision between the intraoral scanners were minimal.


Sujet(s)
Mémorisation et recherche des informations/normes , Microscopie confocale/méthodes , Molaire/imagerie diagnostique , Tomographie par cohérence optique/méthodes , Céramiques/composition chimique , Humains , Inlays/méthodes , Lasers , Microscopie confocale/instrumentation , Microscopie confocale/normes , Résines synthétiques/composition chimique , Logiciel , Tomographie par cohérence optique/instrumentation , Tomographie par cohérence optique/normes
7.
Article de Espagnol | BINACIS | ID: biblio-1096323

RÉSUMÉ

La restauración con sistema de endoposte de fibra mediante técnica de individualización o anatómica es conocida desde hace tiempo. Se presenta una alternativa para ser realizada de manera semidirecta mediante la confección de un modelo flexible translúcido que permite reducir algunos inconvenientes de la técnica directa de individualización. El material empleado para el modelo es un material de bajo costo y accesible para cualquier profesional que desee emplear esta alternativa de restauración. (AU)


Anatomical or individualized fiber post technique has been used for many years now. An alternative is presented to be done chairside with a flexible and translucid model obtained that allows to reduce some drawbacks of the direct anatomical technique. The material used is less expensive than other options and might be used by any professional that want to learn this technique. (AU)


Sujet(s)
Humains , Mâle , Fibres minérales , Restaurations dentaires permanentes/tendances , Incisive , Inlays/méthodes , Restaurations dentaires permanentes/méthodes , Odontologie/méthodes , Réparation de restauration dentaire/méthodes
8.
Br Dent J ; 225(3): 223-228, 2018 08 10.
Article de Anglais | MEDLINE | ID: mdl-30072789

RÉSUMÉ

Aims: To evaluate whether bonded resin composite restorations can effectively immobilise the tooth segments in teeth with a synthesised crack under loading, by exploring the impact of the restoration type (direct versus indirect composite resin) and restoration design (inlay versus onlay) on the fatigue resistance. Methods: Sound human third molars underwent large mesio-occluso-distal preparations and a groove was cut to simulate a crack. Standardised procedures were adopted and measures were taken during teeth selection so that systematic error and methodology bias were minimised. The teeth were randomly assigned to four groups. The specimens were submitted to cyclic loading and loaded until fracture or to a maximum of 185,000 cycles. The failure mode was recorded. Results: No failure was observed in 'direct' groups up to the 1000 N force. Survival analysis revealed statistically significant higher survival rates for 'direct' groups compared to 'indirect' groups (χ2 = 11.352, df = 1, p = 0.001) while there was no significant difference between 'inlay' and 'onlay' groups (χ2 = 0.015, df = 1, p = 0.901) (pooled data). Conclusions: Within the limitations of this in-vitro study, it can be concluded that the direct composite resin restorations sufficiently protected the cracked teeth regardless of the cavity design. As there was no statistically significant difference in survival rates between inlays and onlays it is not possible to favour one design type over the other.


Sujet(s)
Résines composites , Inlays/méthodes , Fractures dentaires/thérapie , Préparation de cavité dentaire , Analyse du stress dentaire , Humains , Inlays/effets indésirables
9.
J Appl Oral Sci ; 26: e20180004, 2018.
Article de Anglais | MEDLINE | ID: mdl-30133672

RÉSUMÉ

Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from leucite ceramic; BD- conventional onlay preparation with boxes made from lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); NBL- conservative onlay preparation with boxes made from lithium disilicate glass ceramic cuspal deformation (µS) was measured at 100 N and at maximum fracture load using strain gauge. Fracture resistance (N) was measured using a compression test, and the fracture mode was recorded. Finite element analysis was used to evaluate the stress distribution by modified von Mises stress criteria. The tooth strain and fracture resistance data were analyzed using the Tukey test and two-way ANOVA, and the fracture mode was analyzed by the chi-square test (α=0.05). Results The leucite ceramic resulted in higher tooth deformation at 100 N and lower tooth deformation at the maximum fracture load than the lithium disilicate ceramic (P<0.001). The lithium disilicate ceramic exhibited higher fracture resistance than the leucite ceramic (P<0.001). The conservative onlay resulted in higher fracture strength for lithium disilicate ceramic. Finite element analysis results showed the conventional cavity preparation resulted in higher stress concentration in the ceramic restoration and remaining tooth than the conservative onlay preparation. The conservative onlays exhibited increased fracture resistance, reduced stress concentration and more favorable fracture modes. Conclusion Molars restored with lithium disilicate CAD-CAM ceramic onlays exhibited higher fracture resistance than molars restored with leucite CAD-CAM ceramic onlays.


Sujet(s)
Silicates d'aluminium/composition chimique , Céramiques/composition chimique , Conception assistée par ordinateur , Préparation de cavité dentaire/méthodes , Porcelaine dentaire/composition chimique , Inlays/méthodes , Fractures dentaires , Résines acryliques/composition chimique , Analyse de variance , Résines composites/composition chimique , Échec de restauration dentaire , Analyse du stress dentaire , Module d'élasticité , Analyse des éléments finis , Humains , Test de matériaux , Molaire , Polyuréthanes/composition chimique , Valeurs de référence , Reproductibilité des résultats , Statistique non paramétrique
10.
Odovtos (En línea) ; 20(2): 17-29, May.-Aug. 2018. graf
Article de Anglais | LILACS, BBO - Ondontologie | ID: biblio-1091443

RÉSUMÉ

Abstract Clinical research and in vitro laboratory tests have enabled the development and improvement of dental ceramics. Comprehension of the physical and mechanical properties of this material is essential, in order to ensure a functional, aesthetic and long-lasting posterior ceramic restoration. The clinical protocol for onlay preparation involves important considerations in treatment planning, such as selection of the restorative material, biomechanical design, color selection, dental substrates conditioning and adhesive cementation. This article discusses a brief review on the topic and a case presentation in which a posterior tooth was rehabilitated with an IPS Empress Esthetic® ceramic onlay.


Resumen La investigación clínica y las pruebas de laboratorio in vitro han permitido el desarrollo de los materiales cerámicos en odontología. La comprensión de las propiedades físicas y mecánicas de este material es esencial para asegurar una restauración funcional, estética y duradera. El protocolo clínico para la preparación de un onlay implica consideraciones importantes en la planificación del tratamiento, tales como la selección del material restaurador, diseño biomecánico, selección de color, acondicionamiento de sustratos dentales y cementación adhesiva. Este artículo discute una breve revisión sobre el tema y una presentación de caso en la que un diente posterior fue rehabilitado con una restauración indirecta tipo Onlay.


Sujet(s)
Humains , Femelle , Adulte , Cimentation , Restaurations dentaires permanentes/méthodes , Inlays/méthodes
11.
Gen Dent ; 66(4): 51-55, 2018.
Article de Anglais | MEDLINE | ID: mdl-29964249

RÉSUMÉ

This in vitro study evaluated the marginal microleakage of composite inlays luted with 3 different cement systems. The null hypothesis was that the luting materials would not influence dye penetration, showing the same degree of microleakage. Thirty-six sound molars were selected, mesio-occlusodistal cavities were prepared, and the teeth were randomly divided into 3 groups (n = 12). Composite resin inlay restorations were made and cemented using a dual-curing resin cement (Calibra), a light-curing flowable composite (Charisma Flow), or a self-adhesive resin cement (RelyX Unicem). The restored teeth were subjected to fatigue cycles and immersed in 0.5% basic fuchsin dye for 24 hours. Two orthogonal cuts were made to enable evaluation of dye penetration at the cervical and occlusal margins. The sections were evaluated with a 4-point scale ranging from 0 (no penetration) to 3 (penetration up to the cavity floor [occlusal margins] or axial wall [cervical margins]). The Calibra and Charisma Flow groups showed greater microleakage, notably at the cervical margins, whereas RelyX Unicem specimens showed the least dye penetration. Significant differences were found between the Calibra and Charisma Flow groups and between the Charisma Flow and RelyX Unicem groups (P < 0.05). No statistically significant differences were detected between the Calibra and RelyX Unicem groups. The microleakage associated with the flowable composite was significantly greater than that associated with both resin cements, results that discourage its use for luting of Class II composite inlays.


Sujet(s)
Percolation dentaire/étiologie , Inlays/effets indésirables , Résines composites/effets indésirables , Résines composites/usage thérapeutique , Ciments dentaires/usage thérapeutique , Échec de restauration dentaire , Humains , Techniques in vitro , Inlays/méthodes , Molaire/chirurgie , Céments résine/effets indésirables , Céments résine/usage thérapeutique
12.
Niger J Clin Pract ; 21(6): 687-691, 2018 Jun.
Article de Anglais | MEDLINE | ID: mdl-29888712

RÉSUMÉ

OBJECTIVE: The purpose of this study was to evaluate the fracture resistance and failure modes of onlay restorations prepared with different preparation designs. MATERIALS AND METHODS: A total of 42 extracted, mandibular first molars (36, 46) were used and divided into six groups according to preparation design, as follows 1A: Anatomic preparation of cusps/rounded shoulder margin/occlusal groove; 1B: Flat preparation of cusps/rounded shoulder margin/occlusal groove; 2A: Anatomical preparation of cusps/occlusal groove; 2B: Flat preparation of cusps/occlusal groove; 3A: Complete anatomical reduction of cusps/rounded shoulder margin; 3B: Complete flat reduction of cusps/rounded shoulder margin groups; intact tooth: No preparation. Onlays were constructed with 0.5-mm copings of Zirconia ceramic. The copings were veneered with porcelain (IPS e. max Ceram). All samples were subjected to fracture resistance testing. Data were analyzed with Kruskal-Wallis and Bonferroni-Dunn tests. RESULTS: Fracture resistance varied significantly according to preparation design. Among the anatomic occlusal preparation designs, fracture resistance was significantly lower in Group 3 when compared to Groups 1 and 2 (P < 0.05). Among the flat occlusal preparation designs, fracture resistance was significantly higher in Group 1 when compared to Groups 2 and 3 (P < 0.05). CONCLUSION: Preparation design affected the fracture resistance of onlay restorations. Cavities with flat occlusal preparation designs, a groove and shoulder margins (1B) resulted in the highest fracture resistance, whereas teeth prepared with a complete reduction of cusps and shoulder margins (3A) had the lowest fracture resistance.


Sujet(s)
Céramiques , Préparation de cavité dentaire/méthodes , Porcelaine dentaire/composition chimique , Inlays/méthodes , Fractures dentaires/prévention et contrôle , Zirconium , Cimentation/méthodes , Céramiques/composition chimique , Caries dentaires , Humains , Molaire , Préparation préprothétique de dent/méthodes
13.
J Prosthet Dent ; 120(3): 396-402, 2018 Sep.
Article de Anglais | MEDLINE | ID: mdl-29551386

RÉSUMÉ

STATEMENT OF PROBLEM: Factors that may affect the marginal adaptation of computer-aided design and computer-aided manufacturing (CAD-CAM) restorations include preparation design, impression technique, and CAD-CAM system. The influence of impression technique and preparation design on CAD-CAM partial coverage restorations has not been fully addressed. PURPOSE: The purpose of this in vitro study was to investigate the influence of direct and indirect digital scanning techniques and 2 preparation designs on the marginal adaptation of CAD-CAM onlays. MATERIAL AND METHODS: Two mesio-occlusal buccal onlay preparations with reduction of the mesiobuccal cusp were made: conventional preparation (CP) with a 1.2-mm modified shoulder margin and modified preparation (MP) flat cuspal reduction without shoulder. Virtual models were generated from each preparation by using a digital scanner (BlueCam; Dentsply Sirona) from the plastic teeth (direct digital scan) or from the stone dies (indirect digital scan). Onlays were designed using a CAD-CAM system (CEREC 4.0; Dentsply Sirona), and nanoceramic resin blocks (Lava Ultimate Restorative; 3M ESPE) were milled using the CEREC MCX milling machine. Marginal discrepancy was evaluated using an optical stereomicroscope at ×25 magnification in 18 locations distributed along the margins of the preparation. The data were analyzed by using 3-way ANOVA followed by the Tukey HSD test (α=.05). RESULTS: CP presented a statistically significant reduced average marginal adaptation (59 ±50 µm) than did MP (69 ±58 µm) (P<.001). The Tukey HSD test showed the presence of a significantly larger marginal discrepancy in the mesial and buccal locations of MP when compared with CP. Regarding impression techniques, the buccal location presented the smallest average marginal discrepancy in restorations fabricated with indirect impression when compared with direct impression (42 ±33 µm and 60 ±39 µm) (P<.001). CONCLUSIONS: The results showed that conventional preparation with a modified shoulder margin presented improved marginal adaptation compared with modified preparation with flat cuspal reduction. Direct and indirect digital scanning techniques produced restorations within a clinically acceptable range; however, the indirect scanning technique resulted in the fabrication of restorations with superior marginal adaptation on the buccal location.


Sujet(s)
Conception assistée par ordinateur , Technique de prise d'empreinte , Adaptation marginale (odontologie) , Conception de prothèse dentaire/méthodes , Inlays/méthodes , Préparation préprothétique de dent/méthodes , Humains
14.
Braz Oral Res ; 32: e005, 2018 Feb 01.
Article de Anglais | MEDLINE | ID: mdl-29412222

RÉSUMÉ

Optical coherence tomography (OCT) has generally been used as a nondestructive technique to evaluate integrities of composite restorations. We investigated marginal and internal adaptations of ceramic inlay restorations with OCT and compared them to results with the silicone replica technique. Round-shaped class I cavities were prepared on 16 human maxillary first premolar teeth. Ceramic inlays were fabricated. Silicone replicas from inlays were obtained and sectioned to measure marginal and internal adaptations with a stereomicroscope (Leica Dfc 295, Bensheim, Germany). Inlays were cemented on respective teeth. Marginal and internal adaptations were then measured with the OCT system (Thorlabs, New Jersey, USA) in 200- µm intervals. Replica and OCT measurements were compared with independent samples t-tests. A paired t-test was used to evaluate the marginal and internal adaptations of each group (p < 0.05). Marginal and internal adaptations were 100.97 ± 31.36 and 113.94 ± 39.75 µm, respectively, using the replica technique and 28.97 ± 17.86 and 97.87 ± 21.83 µm, respectively, using OCT. The differences between the techniques were significant (p = 0.00 and p = 0.01, respectively). On evaluation within the groups, internal adaptation values were found to be significantly higher than the marginal adaptation values for the replica technique (p = 0.00) and OCT (p = 0.00). Therefore, the replica and OCT techniques showed different results, with higher values of marginal and internal adaptation found with the replica technique. Marginal and internal adaptation values of ceramic inlays, whether measured by replica or OCT techniques, were within clinically acceptable limits.


Sujet(s)
Céramiques/composition chimique , Adaptation marginale (odontologie) , Inlays/méthodes , Techniques des répliques/méthodes , Tomographie par cohérence optique/méthodes , Humains , Test de matériaux , Normes de référence , Valeurs de référence , Reproductibilité des résultats , Céments résine/composition chimique , Propriétés de surface
15.
Oral Maxillofac Surg ; 22(1): 65-69, 2018 Mar.
Article de Anglais | MEDLINE | ID: mdl-29313149

RÉSUMÉ

CONTEXT: Cranioplasty is a frequently performed procedure that uses a variety of reconstruction materials and techniques. In this technical note, we present refinements of computer-aided design-computer-aided manufacturing inlay cranioplasty. OBJECTIVE, DESIGN, AND SETTING: In an attempt to decrease complications related to polyether-ether-ketone (PEEK) cranioplasty, we gradually made changes to implant design and cranioplasty techniques. These changes include under-contouring of the implant and the use of segmented plates for large defects, microplate fixation for small temporal defects, temporal shell implants to reconstruct the temporalis muscle, and perforations to facilitate the drainage of blood and cerebrospinal fluid and serve as fixation points. RESULTS: From June 2016 to June 2017, 18 patients underwent cranioplasty, and a total of 31 PEEK and titanium implants were inserted. All implants were successful. CONCLUSIONS: These changes to implant design and cranioplasty techniques facilitate the insertion and fixation of patient-specific cranial implants and improve esthetic outcomes.


Sujet(s)
Conception assistée par ordinateur , Inlays/méthodes , Cétones , Polyéthylène glycols , Crâne/chirurgie , Benzophénones , Plaques orthopédiques , Esthétique , Polymères
16.
Dent Mater ; 34(4): 587-597, 2018 Apr.
Article de Anglais | MEDLINE | ID: mdl-29366492

RÉSUMÉ

OBJECTIVE: To compare mechanical performance and enamel-crack propensity of direct, semi-direct, and CAD/CAM approaches for large MOD composite-resin restorations. METHODS: 45 extracted maxillary molars underwent standardized slot-type preparation (5-mm depth and bucco-palatal width) including immediate dentin sealing (Optibond FL) for the inlays (30 teeth). Short-fiber reinforced composite-resin (EverX Posterior covered by Gradia Direct Posterior) was used for the direct approach, Gradia Direct Posterior for the semi-direct, and Cerasmart composite resin blocks for CAD/CAM inlays. All inlays were adhesively luted with light-curing composite-resin (preheated Gradia Direct Posterior). Shrinkage-induced enamel cracks were tracked by transillumination photography. Cyclic axial isometric chewing (5-Hz) was simulated, starting with a load of 200N (5000 cycles), followed by stages of 400, 600, 800, 1000, 1200, and 1400N (maximum 30,000 cycles each) until fracture or to a maximum of 185,000 cycles. Survived specimens were subjected to cyclic-load-to-failure test at 30-degree angle on the palatal cusp. RESULTS: Only small shrinkage-induced cracks were found in 47% of the direct restorations compared to 7% and 13% of semi-direct and CAD/CAM inlays, respectively. Survival to accelerated fatigue was similar for all three groups (Kaplan-Meier p>.05) and ranged between 87% (direct) and 93% (semi-direct and CAD/CAM). Cyclic-load-to-failure tests did not yield significant differences either (Life Table analysis, p>.05) with median values of 1675N for CAD/CAM inlays, 1775N for fiber-reinforced direct restorations and 1900N for semi-direct inlays. SIGNIFICANCE: All three restorative techniques yielded excellent mechanical performance above physiological masticatory loads. Direct restorations performed as good as inlays when a short-fiber reinforced composite-resin base was used.


Sujet(s)
Résines composites/composition chimique , Restaurations dentaires permanentes/méthodes , Inlays/méthodes , Conception assistée par ordinateur , Émail dentaire/composition chimique , Matériaux dentaires/composition chimique , Échec de restauration dentaire , Analyse du stress dentaire , Humains , Techniques in vitro , Test de matériaux , Molaire , Céments résine , Propriétés de surface , Transillumination
17.
J. appl. oral sci ; 26: e20180004, 2018. tab, graf
Article de Anglais | LILACS, BBO - Ondontologie | ID: biblio-954510

RÉSUMÉ

Abstract Objective This study aimed to evaluate the effect of the cavity preparation and ceramic type on the stress distribution, tooth strain, fracture resistance and fracture mode of human molar teeth restored with onlays. Material and Methods Forty-eight molars were divided into four groups (n=12) with assorted combinations of two study factors: BL- conventional onlay preparation with boxes made from leucite ceramic (IPS-Empress CAD, Ivoclar Vivadent); NBL- conservative onlay preparation without boxes made from leucite ceramic; BD- conventional onlay preparation with boxes made from lithium disilicate glass ceramic (IPS e.max CAD, Ivoclar Vivadent); NBL- conservative onlay preparation with boxes made from lithium disilicate glass ceramic cuspal deformation (µS) was measured at 100 N and at maximum fracture load using strain gauge. Fracture resistance (N) was measured using a compression test, and the fracture mode was recorded. Finite element analysis was used to evaluate the stress distribution by modified von Mises stress criteria. The tooth strain and fracture resistance data were analyzed using the Tukey test and two-way ANOVA, and the fracture mode was analyzed by the chi-square test (α=0.05). Results The leucite ceramic resulted in higher tooth deformation at 100 N and lower tooth deformation at the maximum fracture load than the lithium disilicate ceramic (P<0.001). The lithium disilicate ceramic exhibited higher fracture resistance than the leucite ceramic (P<0.001). The conservative onlay resulted in higher fracture strength for lithium disilicate ceramic. Finite element analysis results showed the conventional cavity preparation resulted in higher stress concentration in the ceramic restoration and remaining tooth than the conservative onlay preparation. The conservative onlays exhibited increased fracture resistance, reduced stress concentration and more favorable fracture modes. Conclusion Molars restored with lithium disilicate CAD-CAM ceramic onlays exhibited higher fracture resistance than molars restored with leucite CAD-CAM ceramic onlays.


Sujet(s)
Humains , Céramiques/composition chimique , Conception assistée par ordinateur , Préparation de cavité dentaire/méthodes , Porcelaine dentaire/composition chimique , Silicates d'aluminium/composition chimique , Inlays/méthodes , Polyuréthanes/composition chimique , Valeurs de référence , Fractures dentaires , Résines acryliques/composition chimique , Test de matériaux , Reproductibilité des résultats , Analyse de variance , Statistique non paramétrique , Résines composites/composition chimique , Échec de restauration dentaire , Analyse des éléments finis , Analyse du stress dentaire , Module d'élasticité , Molaire
18.
Braz. oral res. (Online) ; 32: e005, 2018. tab, graf
Article de Anglais | LILACS | ID: biblio-889474

RÉSUMÉ

Abstract Optical coherence tomography (OCT) has generally been used as a nondestructive technique to evaluate integrities of composite restorations. We investigated marginal and internal adaptations of ceramic inlay restorations with OCT and compared them to results with the silicone replica technique. Round-shaped class I cavities were prepared on 16 human maxillary first premolar teeth. Ceramic inlays were fabricated. Silicone replicas from inlays were obtained and sectioned to measure marginal and internal adaptations with a stereomicroscope (Leica Dfc 295, Bensheim, Germany). Inlays were cemented on respective teeth. Marginal and internal adaptations were then measured with the OCT system (Thorlabs, New Jersey, USA) in 200- μm intervals. Replica and OCT measurements were compared with independent samples t-tests. A paired t-test was used to evaluate the marginal and internal adaptations of each group (p < 0.05). Marginal and internal adaptations were 100.97 ± 31.36 and 113.94 ± 39.75 μm, respectively, using the replica technique and 28.97 ± 17.86 and 97.87 ± 21.83 μm, respectively, using OCT. The differences between the techniques were significant (p = 0.00 and p = 0.01, respectively). On evaluation within the groups, internal adaptation values were found to be significantly higher than the marginal adaptation values for the replica technique (p = 0.00) and OCT (p = 0.00). Therefore, the replica and OCT techniques showed different results, with higher values of marginal and internal adaptation found with the replica technique. Marginal and internal adaptation values of ceramic inlays, whether measured by replica or OCT techniques, were within clinically acceptable limits.


Sujet(s)
Humains , Céramiques/composition chimique , Adaptation marginale (odontologie) , Inlays/méthodes , Techniques des répliques/méthodes , Tomographie par cohérence optique/méthodes , Test de matériaux , Normes de référence , Valeurs de référence , Reproductibilité des résultats , Céments résine/composition chimique , Propriétés de surface
19.
Oper Dent ; 42(5): E134-E138, 2017.
Article de Anglais | MEDLINE | ID: mdl-28829930

RÉSUMÉ

Although rare, subcutaneous air emphysema can occur during dental procedures such as endodontic treatment, surgical extractions, and preparing a tooth for an indirect or direct dental restoration. We report the development of a subcutaneous air emphysema that was introduced through the periodontal ligament of an untreated premolar after the use of an air syringe to dry the tooth.


Sujet(s)
Prémolaire/chirurgie , Équipement dentaire pour grandes vitesses/effets indésirables , Emphysème sous-cutané/étiologie , Humains , Inlays/effets indésirables , Inlays/méthodes , Mâle , Maxillaire , Adulte d'âge moyen , Bouche
20.
J Am Dent Assoc ; 148(9): 671-676, 2017 09.
Article de Anglais | MEDLINE | ID: mdl-28366225

RÉSUMÉ

BACKGROUND AND OVERVIEW: Besides indirect use in the laboratory and direct use for restorations, composites can be used in semidirect procedures. The authors describe the semidirect composite restoration technique by using a flexible die for large lesions in posterior teeth. CASE DESCRIPTION: The authors present illustrations of the clinical steps and the outcomes immediately after the procedures. The authors placed chairside inlay, onlay, and overlay composite restorations. The final esthetic outcome, along with function and anatomic form recovery, demonstrated that this might be a viable cost-effective alternative technique to laboratory-fabricated indirect restorations. CONCLUSIONS AND PRACTICAL IMPLICATIONS: Clinicians can restore large preparations in posterior teeth successfully with semidirect composite restorations in a single appointment by using the flexible die technique, resulting in satisfactory function and esthetic outcome.


Sujet(s)
Résines composites/usage thérapeutique , Restaurations dentaires permanentes/méthodes , Adulte , Technique de prise d'empreinte , Humains , Inlays/méthodes , Adulte d'âge moyen , Molaire/chirurgie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...