Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 4.000
Filtrer
1.
J Cardiothorac Surg ; 19(1): 329, 2024 Jun 12.
Article de Anglais | MEDLINE | ID: mdl-38867224

RÉSUMÉ

Iatrogenic aortic regurgitation secondary to leaflet injury is a rare complication of mitral valve surgery. For the first time, we report a patient who had progressive aortic regurgitation due to non-coronary leaflet perforation after robotic mitral valve repair and required aortic valve repair 18 months after this initial surgery. As in our case, aortic regurgitation after mitral valve surgery may remain undiagnosed on intraoperative transesophageal echocardiography or undetected until the patient's discharge due to gradual enlargement of very small perforations over the postoperative course.


Sujet(s)
Insuffisance aortique , Échocardiographie transoesophagienne , Maladie iatrogène , Insuffisance mitrale , Valve atrioventriculaire gauche , Interventions chirurgicales robotisées , Humains , Valve atrioventriculaire gauche/chirurgie , Interventions chirurgicales robotisées/effets indésirables , Insuffisance mitrale/chirurgie , Insuffisance aortique/chirurgie , Insuffisance aortique/étiologie , Mâle , Complications postopératoires/étiologie , Complications postopératoires/chirurgie , Implantation de valve prothétique cardiaque/effets indésirables , Femelle
2.
Catheter Cardiovasc Interv ; 103(7): 1093-1100, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38690931

RÉSUMÉ

BACKGROUND: As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates. AIMS: The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR. METHODS: PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups. RESULTS: The total patients' mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was -1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively. CONCLUSIONS: TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.


Sujet(s)
Insuffisance aortique , Valve aortique , Prothèse valvulaire cardiaque , Conception de prothèse , Récupération fonctionnelle , Remplacement valvulaire aortique par cathéter , Humains , Mâle , Femelle , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Insuffisance aortique/physiopathologie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Sujet âgé , Résultat thérapeutique , Sujet âgé de 80 ans ou plus , Valve aortique/chirurgie , Valve aortique/physiopathologie , Valve aortique/imagerie diagnostique , Études rétrospectives , Facteurs temps , Facteurs de risque , Adulte d'âge moyen , Complications postopératoires/étiologie , Hémodynamique
3.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38577923

RÉSUMÉ

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Sujet(s)
, Insuffisance aortique , Valve aortique , Implantation de prothèses vasculaires , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Humains , Mâle , /chirurgie , /imagerie diagnostique , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Insuffisance aortique/physiopathologie , Adulte d'âge moyen , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/instrumentation , Résultat thérapeutique , Implantation de prothèses vasculaires/instrumentation , Implantation de prothèses vasculaires/effets indésirables , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Conception de prothèse , Prothèse vasculaire , Anévrysme de l'aorte thoracique/chirurgie , Anévrysme de l'aorte thoracique/imagerie diagnostique , Anévrysme de l'aorte/chirurgie , Anévrysme de l'aorte/imagerie diagnostique , Aortographie
4.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38577931

RÉSUMÉ

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Sujet(s)
Sténose aortique , Valve aortique , Prothèse valvulaire cardiaque , Hémodynamique , Conception de prothèse , Enregistrements , Remplacement valvulaire aortique par cathéter , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Valve aortique/chirurgie , Valve aortique/physiopathologie , Valve aortique/imagerie diagnostique , Insuffisance aortique/physiopathologie , Insuffisance aortique/étiologie , Insuffisance aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/physiopathologie , Sténose aortique/imagerie diagnostique , Complications postopératoires , Études prospectives , Récupération fonctionnelle , Facteurs de risque , Espagne , Facteurs temps , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
5.
Cardiovasc Pathol ; 71: 107648, 2024.
Article de Anglais | MEDLINE | ID: mdl-38649123

RÉSUMÉ

This case report presents a 20-year-old male patient initially diagnosed with infective endocarditis, later correctly identified as Behçet's syndrome. The patient's complex clinical presentation, including chest pain, aortic dilation, severe aortic regurgitation, and aortic root abscess, posed significant diagnostic and therapeutic challenges. Despite initial misdiagnosis and treatment difficulties, the patient's condition significantly improved with appropriate immunosuppressive therapy, underscoring the potential for successful management of this complex condition. This case serves as a valuable reminder of the diagnostic challenges posed by Behçet's syndrome and the importance of considering this condition in patients presenting with symptoms suggestive of infective endocarditis.


Sujet(s)
Maladie de Behçet , Erreurs de diagnostic , Immunosuppresseurs , Humains , Maladie de Behçet/diagnostic , Maladie de Behçet/traitement médicamenteux , Mâle , Jeune adulte , Immunosuppresseurs/usage thérapeutique , Endocardite/diagnostic , Endocardite/thérapie , Endocardite/traitement médicamenteux , Résultat thérapeutique , Diagnostic différentiel , Insuffisance aortique/chirurgie , Insuffisance aortique/diagnostic , Insuffisance aortique/étiologie , Valeur prédictive des tests
6.
Tex Heart Inst J ; 51(1)2024 Apr 30.
Article de Anglais | MEDLINE | ID: mdl-38686682

RÉSUMÉ

Quadricuspid aortic valve is a rare congenital cardiac anomaly with an incidence of 0.008% to 0.043%. Its clinical course varies depending on cusp anatomy, function, and associated cardiac malformations. It frequently progresses to aortic valve regurgitation that may require surgical valve replacement. Detection has shifted from incidental discovery during autopsies or cardiac surgeries in the early 20th century to various cardiac imaging methods in recent decades. In addition to contributing to the literature, this report supports the use of transesophageal echocardiography more liberally to detect aortic valve abnormalities. The case presents a 48-year-old female patient with an incidentally discovered quadricuspid aortic valve.


Sujet(s)
Insuffisance aortique , Valve aortique , Échocardiographie transoesophagienne , Cardiopathies congénitales , Résultats fortuits , Humains , Femelle , Valve aortique/malformations , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Adulte d'âge moyen , Échocardiographie transoesophagienne/méthodes , Insuffisance aortique/chirurgie , Insuffisance aortique/diagnostic , Insuffisance aortique/étiologie , Cardiopathies congénitales/diagnostic , Cardiopathies congénitales/chirurgie , Cardiopathies congénitales/imagerie diagnostique , Valeur prédictive des tests , Implantation de valve prothétique cardiaque , Échocardiographie-doppler couleur
7.
EuroIntervention ; 20(6): e363-e375, 2024 03 18.
Article de Anglais | MEDLINE | ID: mdl-38506737

RÉSUMÉ

BACKGROUND: There is a lack of comparative data on transcatheter aortic valve implantation (TAVI) in degenerated surgical prostheses (valve-in-valve [ViV]). AIMS: We sought to compare outcomes of using two self-expanding transcatheter heart valve (THV) systems for ViV. METHODS: In this retrospective multicentre registry, we included consecutive patients undergoing transfemoral ViV using either the ACURATE neo/neo2 (ACURATE group) or the Evolut R/PRO/PRO+ (EVOLUT group). The primary outcome measure was technical success according to Valve Academic Research Consortium (VARC)-3. Secondary outcomes were 30-day all-cause mortality, device success (VARC-3), coronary obstruction (CO) requiring intervention, rates of severe prosthesis-patient mismatch (PPM), and aortic regurgitation (AR) ≥moderate. Comparisons were made after 1:1 propensity score matching. RESULTS: The study cohort comprised 835 patients from 20 centres (ACURATE n=251; EVOLUT n=584). In the matched cohort (n=468), technical success (ACURATE 92.7% vs EVOLUT 88.9%; p=0.20) and device success (69.7% vs 73.9%; p=0.36) as well as 30-day mortality (2.8% vs 1.6%; p=0.392) were similar between the two groups. The mean gradients and rates of severe PPM, AR ≥moderate, or CO did not differ between the groups. Technical and device success were higher for the ACURATE platform among patients with a true inner diameter (ID) >19 mm, whereas a true ID ≤19 mm was associated with higher device success - but not technical success - among Evolut recipients. CONCLUSIONS: ViV TAVI using either ACURATE or Evolut THVs showed similar procedural outcomes. However, a true ID >19 mm was associated with higher device success among ACURATE recipients, whereas in patients with a true ID ≤19 mm, device success was higher when using Evolut.


Sujet(s)
Insuffisance aortique , Bioprothèse , Occlusion coronarienne , Remplacement valvulaire aortique par cathéter , Humains , Cathéters , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Valves cardiaques , Enregistrements , Remplacement valvulaire aortique par cathéter/effets indésirables
8.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article de Anglais | MEDLINE | ID: mdl-38544298

RÉSUMÉ

Pure aortic regurgitation and dilation of aortic annulus are the most significant risk factors for the failure of pulmonary autograft after the Ross procedure. Aortic annuloplasty has a positive effect on the durability of the autograft. Previously, we described a technique for external annuloplasty with dedicated CORONEO ring. In the present manuscript, we suggest the sizing of annuloplasty based on the diameter of pulmonary autograft annulus.


Sujet(s)
Insuffisance aortique , Sténose aortique , Valve du tronc pulmonaire , Humains , Autogreffes , Transplantation autologue/effets indésirables , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/chirurgie , Insuffisance aortique/étiologie , Sténose aortique/chirurgie , Réintervention/effets indésirables , Valve du tronc pulmonaire/transplantation , Résultat thérapeutique , Études de suivi
9.
Eur J Cardiothorac Surg ; 65(4)2024 Mar 29.
Article de Anglais | MEDLINE | ID: mdl-38489836

RÉSUMÉ

OBJECTIVES: After staged reconstruction for hypoplastic left heart syndrome, the neoaortic root tends to dilate, and the incidence of significant neoaortic valve insufficiency increases with time. This study aimed to evaluate the mid-term outcomes of the neoaortic root geometries and valve function after chimney reconstruction in the Norwood procedure. METHODS: Between 2013 and 2021, 20 consecutive patients who underwent chimney reconstruction during the Norwood procedure for hypoplastic left heart syndrome and its variants in our institution were enrolled. The actual diameters of the following points were measured, and Z-scores were calculated based on the normal aortic root geometries using the long axis view of echocardiography at the pre-Norwood stage and the lateral view of angiography at pre-Glenn, pre-Fontan, post-Fontan and follow-up (age 5-6 years) stages: neoaortic valve annulus; sinus of Valsalva; sinotubular junction; and ascending aorta just proximal to the anastomosis to the aortic arch. The degree of neoaortic valve regurgitation was evaluated by echocardiography at each stage. RESULTS: The median follow-up period was 3.9 years. Neoaortic roots after chimney reconstruction were spared from progressive dilation over time. With growth, the conical configuration of the neoaortic roots was preserved without geometrical distortion. The Z-scores of the annulus, sinus of Valsalva, sinotubular junction and ascending aorta ranged roughly from 4 to 6, 4 to 6, 2 to 4 and 0 to 2, respectively. All neoaortic valves at each stage had mild or no regurgitation. CONCLUSIONS: Chimney reconstruction prevented neoaortic root dilation and avoided significant neoaortic valve regurgitation in the mid-term. These neoaortic dimensions with smooth flow profiles in the neoaorta after chimney reconstruction may have contributed to the current results. Further studies are needed to clarify the long-term outcomes.


Sujet(s)
Insuffisance aortique , Hypoplasie du coeur gauche , Procédures de Norwood , Humains , Enfant d'âge préscolaire , Enfant , Hypoplasie du coeur gauche/chirurgie , Résultat thérapeutique , Procédures de Norwood/effets indésirables , Aorte/chirurgie , Échocardiographie , Insuffisance aortique/chirurgie , Insuffisance aortique/étiologie , Études de suivi , Études rétrospectives
11.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38532517

RÉSUMÉ

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Sujet(s)
Valve aortique , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Adulte d'âge moyen , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/physiopathologie , Insuffisance aortique/chirurgie , Insuffisance aortique/étiologie , Prothèse vasculaire , Implantation de prothèses vasculaires/instrumentation , Implantation de prothèses vasculaires/effets indésirables , Entraînement électrosystolique , Implantation de valve prothétique cardiaque/instrumentation , Implantation de valve prothétique cardiaque/effets indésirables , Défaillance de prothèse , Récupération fonctionnelle , Appréciation des risques , Facteurs de risque , Facteurs temps , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
12.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38533653

RÉSUMÉ

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Sujet(s)
Insuffisance aortique , Valvuloplastie par ballonnet , Modèles animaux de maladie humaine , Hémodynamique , Animaux , Hémodynamique/effets des médicaments et des substances chimiques , Insuffisance aortique/physiopathologie , Insuffisance aortique/étiologie , Insuffisance aortique/imagerie diagnostique , Sus scrofa , Valve aortique/physiopathologie , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Conception d'appareillage , Récupération fonctionnelle , Maladie aigüe , Sondes cardiaques , Facteurs temps , Indice de gravité de la maladie , Fonction ventriculaire gauche/effets des médicaments et des substances chimiques
14.
Kyobu Geka ; 77(3): 206-209, 2024 Mar.
Article de Japonais | MEDLINE | ID: mdl-38465492

RÉSUMÉ

We report a case of bioprosthetic valve dysfunction and acute aortic valve regurgitation. The case was a 75-year-old female who had sudden onset chest pain. ST-segment depression in several leads on electrocardiogram( ECG) suggested acute coronary syndrome. Coronary angiography showed no significant stenosis in coronary arteries. Transesophageal echocardiography revealed severe aortic regurgitation, suggesting that angina was caused by myocardial ischemia associated with acute aortic regurgitation. She was diagnosed as having bioprosthetic valve dysfunction, and underwent redo aortic valve replacement. One leaflet of the bioprosthetic valve was torn along the stent post and caused bioprosthetic valve dysfunction. Failed bioprosthetic valve was removed and replaced by a mechanical valve.


Sujet(s)
Insuffisance aortique , Bioprothèse , Implantation de valve prothétique cardiaque , Prothèse valvulaire cardiaque , Femelle , Humains , Sujet âgé , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Thorax , Prothèse valvulaire cardiaque/effets indésirables , Douleur thoracique/étiologie , Bioprothèse/effets indésirables , Implantation de valve prothétique cardiaque/effets indésirables
15.
Lancet ; 403(10435): 1451-1459, 2024 Apr 13.
Article de Anglais | MEDLINE | ID: mdl-38552656

RÉSUMÉ

BACKGROUND: Surgery remains the only recommended intervention for patients with native aortic regurgitation. A transcatheter therapy to treat patients at high risk for mortality and complications with surgical aortic valve replacement represents an unmet need. Commercial transcatheter heart valves in pure aortic regurgitation are hampered by unacceptable rates of embolisation and paravalvular regurgitation. The Trilogy transcatheter heart valve (JenaValve Technology, Irvine, CA, USA) provides a treatment option for these patients. We report outcomes with transfemoral transcatheter aortic valve implantation (TAVI) in patients with pure aortic regurgitation using this dedicated transcatheter heart valve. METHODS: The ALIGN-AR trial is a prospective, multicentre, single-arm study. We recruited symptomatic patients (aged ≥18 years) with moderate-to-severe or severe aortic regurgitation at high risk for mortality and complications after surgical aortic valve replacement at 20 US sites for treatment with the Trilogy transcatheter heart valve. The 30-day composite primary safety endpoint was compared for non-inferiority with a prespecified performance goal of 40·5%. The primary efficacy endpoint was 1-year all-cause mortality compared for non-inferiority with a performance goal of 25%. This trial is registered with ClinicalTrials.gov, NCT04415047, and is ongoing. FINDINGS: Between June 8, 2018, and Aug 29, 2022, we screened 346 patients. We excluded 166 (48%) patients and enrolled 180 (52%) patients with symptomatic aortic regurgitation deemed high risk by the heart team and independent screening committee assessments. The mean age of the study population was 75·5 years (SD 10·8), and 85 (47%) were female, 95 (53%) were male, and 131 (73%) were White. Technical success was achieved in 171 (95%) patients. At 30 days, four (2%) deaths, two (1%) disabling strokes, and two (1%) non-disabling strokes occurred. Using standard Valve Academic Research Consortium-2 definitions, the primary safety endpoint was achieved, with events occurring in 48 (27% [97·5% CI 19·2-34·0]) patients (pnon-inferiority<0·0001), with new pacemaker implantation in 36 (24%) patients. The primary efficacy endpoint was achieved, with mortality in 14 (7·8% [3·3-12·3]) patients at 1 year (pnon-inferiority<0·0001). INTERPRETATION: This study shows the safety and effectiveness of treating native aortic regurgitation using a dedicated transcatheter heart valve to treat patients with symptomatic moderate-to-severe or severe aortic regurgitation who are at high risk for mortality or complications after surgical aortic valve replacement. The observed short-term clinical and haemodynamic outcomes are promising as are signs of left ventricular remodelling, but long-term follow-up is necessary. FUNDING: JenaValve Technology.


Sujet(s)
Insuffisance aortique , Sténose aortique , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Adolescent , Adulte , Sujet âgé , Femelle , Humains , Mâle , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Sténose aortique/chirurgie , Études prospectives , Conception de prothèse , Facteurs de risque , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
16.
Glob Heart ; 19(1): 16, 2024.
Article de Anglais | MEDLINE | ID: mdl-38344744

RÉSUMÉ

Background: Acute rheumatic fever (ARF) with carditis can lead to the development of rheumatic heart disease in children and young adults. Objective: This study aimed to investigate the manifestations of rheumatic carditis, clinically significant regression of valvular regurgitation as assessed by echocardiography, and the independent predictors of mitral regurgitation (MR) improvement after rheumatic carditis in Thai children. Method: Children diagnosed with rheumatic carditis during 2005-2020 at Siriraj Hospital (Bangkok, Thailand) were retrospectively enrolled. Trivial, and mild regurgitation were grouped as non-clinically significant (NCS) regurgitation. Valvular regression was defined moderate-severe regurgitation improving to NCS regurgitation. Results: Eighty-one patients (mean age: 10 years, range: 8-12 years) were included. At presentation, 59 (72.8%) patients had combined mitral regurgitation (MR) and aortic regurgitation (AR), 20 (24.6%) patients had MR alone, and 2 (2.4%) patients had AR alone. Concerning severity, 28 (34.6%) and 30 (37%) patients presented with severe and moderate MR, respectively. Severe and moderate AR was found in 9 (11.1%) and 16 (19.8%) patients, respectively. At the one-year follow-up, 43.4% of moderate-severe MR, and 41.7% of moderate-severe AR improved to NCS regurgitation. Multivariate analysis revealed high erythrocyte sedimentation rate (ESR) (p = 0.01) and severe carditis (p = 0.05) at presentation to be independent predictors of MR improvement. Conclusion: Thai children with rheumatic carditis had a high incidence of valvular regurgitation; however, the valvular damage was improved in most patients. High ESR and severe carditis independently predict MR improvement.


Sujet(s)
Insuffisance aortique , Valvulopathies , Insuffisance mitrale , Myocardite , Rhumatisme articulaire aigu , Rhumatisme cardiaque , Enfant , Jeune adulte , Humains , Rhumatisme cardiaque/complications , Rhumatisme cardiaque/épidémiologie , Insuffisance mitrale/épidémiologie , Insuffisance mitrale/complications , Thaïlande/épidémiologie , Myocardite/épidémiologie , Études rétrospectives , Insuffisance aortique/épidémiologie , Insuffisance aortique/diagnostic , Insuffisance aortique/étiologie
17.
Eur Heart J Cardiovasc Imaging ; 25(7): 929-936, 2024 Jun 28.
Article de Anglais | MEDLINE | ID: mdl-38306632

RÉSUMÉ

AIMS: To compare the novel 2D multi-velocity encoding (venc) and 4D flow acquisitions with the standard 2D flow acquisition for the assessment of paravalvular regurgitation (PVR) after transcatheter aortic valve replacement (TAVR) using cardiac magnetic resonance (CMR)-derived regurgitant fraction (RF). METHODS AND RESULTS: In this prospective study, patients underwent CMR 1 month after TAVR for the assessment of PVR, for which 2D multi-venc and 4D flow were used, in addition to standard 2D flow. Scatterplots and Bland-Altman plots were used to assess correlation and visualize agreement between techniques. Reproducibility of measurements was assessed with intraclass correlation coefficients. The study included 21 patients (mean age ± SD 80 ± 5 years, 9 men). The mean RF was 11.7 ± 10.0% when standard 2D flow was used, 10.6 ± 7.0% when 2D multi-venc flow was used, and 9.6 ± 7.3% when 4D flow was used. There was a very strong correlation between the RFs assessed with 2D multi-venc and standard 2D flow (r = 0.88, P < 0.001), and a strong correlation between the RFs assessed with 4D flow and standard 2D flow (r = 0.74, P < 0.001). Bland-Altman plots revealed no substantial bias between the RFs (2D multi-venc: 1.3%; 4D flow: 0.3%). Intra-observer and inter-observer reproducibility for 2D multi-venc flow were 0.98 and 0.97, respectively, and 0.92 and 0.90 for 4D flow, respectively. CONCLUSION: Two-dimensional multi-venc and 4D flow produce an accurate quantification of PVR after TAVR. The fast acquisition of the 2D multi-venc sequence and the free-breathing acquisition with retrospective plane selection of the 4D flow sequence provide useful advantages in clinical practice, especially in the frail TAVR population.


Sujet(s)
Insuffisance aortique , IRM dynamique , Remplacement valvulaire aortique par cathéter , Humains , Mâle , Remplacement valvulaire aortique par cathéter/effets indésirables , Femelle , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Insuffisance aortique/physiopathologie , Études prospectives , Sujet âgé de 80 ans ou plus , Sujet âgé , IRM dynamique/méthodes , Sténose aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/physiopathologie , Reproductibilité des résultats , Vitesse du flux sanguin , Complications postopératoires/imagerie diagnostique , Indice de gravité de la maladie , Études de cohortes
18.
J Am Heart Assoc ; 13(4): e033289, 2024 Feb 20.
Article de Anglais | MEDLINE | ID: mdl-38362873

RÉSUMÉ

BACKGROUND: The management of mixed aortic valve disease (MAVD), defined as the concomitant presence of aortic stenosis (AS) and aortic regurgitation, remains a clinical challenging. The present study assessed the impact of transcatheter aortic valve replacement (TAVR) on cardiac geometry and prognosis in patients with MAVD. METHODS AND RESULTS: A retrospective multicenter TAVR registry was conducted, including patients who underwent TAVR for severe symptomatic AS between January 2015 and March 2019. Patients were subdivided into 2 groups according to concomitant presence of moderate or more severe aortic regurgitation as the MAVD group, and with mild or less severe aortic regurgitation as the isolated AS group. The primary outcome was a composite of cardiovascular death and rehospitalization due to cardiovascular causes. A total of 1742 patients (isolated AS, 1522 patients; MAVD, 220 patients) were included (84.0±5.2 years). Although MAVD exhibited significantly larger left ventricular volumes and higher left ventricular mass index at the TAVR procedure than isolated AS (respectively, P<0.001), MAVD showed a greater improvement of left ventricular volumes and left ventricular mass index after TAVR (respectively, P≤0.001). During a median follow-up of 747 days, 301 patients achieved the primary event. The prognosis post-TAVR was comparable between the 2 groups (log-rank P=0.65). Even after adjustment using propensity score matching to reduce the potential bias between the 2 groups, similar results were obtained for the entire cohort. CONCLUSIONS: Despite more advanced cardiac remodeling in MAVD at the time of TAVR compared with isolated AS, a greater improvement of cardiac reverse remodeling was found in MAVD, and the prognosis following TAVR was comparable between the 2 groups.


Sujet(s)
Insuffisance aortique , Sténose aortique , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/méthodes , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/chirurgie , Insuffisance aortique/étiologie , Résultat thérapeutique , Facteurs de risque , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/étiologie , Pronostic , Études rétrospectives , Indice de gravité de la maladie , Fonction ventriculaire gauche
20.
Circ J ; 88(5): 663-671, 2024 Apr 25.
Article de Anglais | MEDLINE | ID: mdl-38325819

RÉSUMÉ

BACKGROUND: Complications arising from transcatheter closure of perimembranous ventricular septal defects (pmVSD) in children, such as residual shunts and aortic regurgitation (AR), have been observed. However, the associated risk factors remain unclear. This study identified risk factors linked with residual shunts and AR following transcatheter closure of pmVSD in children aged 2-12 years.Methods and Results: The medical records of 63 children with pmVSD and a pulmonary-to-systemic blood flow ratio <2.0 who underwent transcatheter closure between 2011 and 2018 were analyzed with a minimum 3-year follow-up. The success rate of transcatheter closure was 98.4%, with no emergency surgery, permanent high-degree atrioventricular block, or mortality. Defects ≥4.5 mm had significantly higher odds of persistent residual shunt (odds ratio [OR] 6.85; P=0.03). The use of an oversize device (≥1.5 mm) showed a trend towards reducing residual shunts (OR 0.23; P=0.06). Age <4 years (OR 27.38; 95% confidence interval [CI] 2.33-321.68) and perimembranous outlet-type VSD (OR 11.94, 95% CI 1.10-129.81) were independent risk factors for AR progression after closure. CONCLUSIONS: Careful attention is crucial for pmVSDs ≥4.5 mm to prevent persistent residual shunts in transcatheter closure. Assessing AR risk, particularly in children aged <4 years, is essential while considering the benefits of pmVSD closure.


Sujet(s)
Cathétérisme cardiaque , Communications interventriculaires , Humains , Communications interventriculaires/chirurgie , Enfant d'âge préscolaire , Enfant , Facteurs de risque , Mâle , Femelle , Cathétérisme cardiaque/effets indésirables , Études rétrospectives , Dispositif d'occlusion septale/effets indésirables , Résultat thérapeutique , Insuffisance aortique/étiologie , Facteurs âges , Facteurs temps , Études de suivi , Complications postopératoires/étiologie
SÉLECTION CITATIONS