Résultats 1 - 20 de 3.505
Filtrer
1.
JACC Cardiovasc Interv ; 17(13): 1597-1606, 2024 Jul 08.
Article de Anglais | MEDLINE | ID: mdl-38986659

RÉSUMÉ

BACKGROUND: Severe pure aortic regurgitation (AR) carries a high mortality and morbidity risk, and it is often undertreated because of the inherent surgical risk. Transcatheter heart valves (THVs) have been used off-label in this setting with overall suboptimal results. The dedicated "purpose-built" Jena Valve Trilogy (JVT, JenaValve Technology) showed an encouraging performance, although it has never been compared to other THVs. OBJECTIVES: The aim of our study was to assess the performance of the latest iteration of THVs used off-label in comparison to the purpose-built JVT in inoperable patients with severe AR. METHODS: We performed a multicenter, retrospective registry with 18 participating centers worldwide collecting data on inoperable patients with severe AR of the native valve. A bicuspid aortic valve was the main exclusion criterion. The primary endpoints were technical and device success, 1-year all-cause mortality, and the composite of 1-year mortality and the heart failure rehospitalization rate. RESULTS: Overall, 256 patients were enrolled. THVs used off-label were used in 168 cases (66%), whereas JVT was used in 88 (34%). JVT had higher technical (81% vs 98%; P < 0.001) and device success rates (73% vs 95%; P < 0.001), primarily driven by significantly lower incidences of THV embolization (15% vs 1.1%; P < 0.001), the need for a second valve (11% vs 1.1%; P = 0.004), and moderate residual AR (10% vs 1.1%; P = 0.007). The permanent pacemaker implantation rate was comparable and elevated for both groups (22% vs 24%; P = 0.70). Finally, no significant difference was observed at the 1-year follow-up in terms of mortality (HR: 0.99; P = 0.980) and the composite endpoint (HR: 1.5; P = 0.355). CONCLUSIONS: The JVT platform has a better acute performance than other THVs when used off-label for inoperable patients with severe AR. A longer follow-up is conceivably needed to detect a possible impact on prognosis.


Sujet(s)
Insuffisance aortique , Valve aortique , Prothèse valvulaire cardiaque , Conception de prothèse , Enregistrements , Indice de gravité de la maladie , Remplacement valvulaire aortique par cathéter , Humains , Insuffisance aortique/physiopathologie , Insuffisance aortique/mortalité , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Femelle , Mâle , Études rétrospectives , Sujet âgé , Résultat thérapeutique , Sujet âgé de 80 ans ou plus , Facteurs de risque , Valve aortique/chirurgie , Valve aortique/physiopathologie , Valve aortique/imagerie diagnostique , Facteurs temps , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/mortalité , Remplacement valvulaire aortique par cathéter/instrumentation , Réadmission du patient , Récupération fonctionnelle , Europe , Défaillance cardiaque/mortalité , Défaillance cardiaque/thérapie , Défaillance cardiaque/physiopathologie , Défaillance cardiaque/diagnostic , Hémodynamique
3.
J Med Case Rep ; 18(1): 314, 2024 Jul 09.
Article de Anglais | MEDLINE | ID: mdl-38978082

RÉSUMÉ

BACKGROUND: The current study presents a novel and precise surgical technique for complete reconstruction of the aortic valve using glutaraldehyde-treated autologous pericardium in a patient with aortic valve disease and endocarditis. The technique aims to provide a more effective and reproducible method for aortic valve repair, with the goal of improving outcomes and quality of life for patients with aortic valve disease. CASE PRESENTATION: A 35-year-old Iranian male with aortic valve disease and endocarditis underwent aortic valve reconstruction surgery. Preoperative echocardiography showed a degenerative aortic valve with severe regurgitation, reduced left ventricular ejection fraction, and specific aortic root dimensions. The surgical technique involved precise measurements and calculations to design the size and shape of the new aortic valve cusps using autologous pericardium, with the goal of optimizing coaptation and function. The surgeon calculated the intercommissural distance based on the aortic annulus diameter to determine cusp size and shape. He tailored the pericardial cusps to have a height equal to 80% of the coaptation margin length. Detailed suturing techniques were used to ensure proper alignment and coaptation of the new cusps. Intraoperative evaluation of the valve function using suction and transesophageal echocardiography showed good coaptation and minimal residual regurgitation. At the 3-year follow-up, the patient had a well-functioning aortic valve with only trivial leak and was in satisfactory clinical condition. CONCLUSIONS: Glutaraldehyde-treated autologous pericardium is a validated leaflet alternative, and the causes of its failure are late annular dilatation and other technique breakdowns. Current evidence reveals that aortic valve reconstruction with glutaraldehyde-treated autologous pericardium is associated with many advantages with the potential to improve patient outcomes and quality of life. Further clinical studies are warranted to evaluate the long-term durability and efficacy of this approach.


Sujet(s)
Valve aortique , Glutaraldéhyde , Péricarde , Humains , Mâle , Péricarde/transplantation , Adulte , Glutaraldéhyde/usage thérapeutique , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Transplantation autologue , Insuffisance aortique/chirurgie , Insuffisance aortique/imagerie diagnostique , /méthodes , Maladie de la valve aortique/chirurgie , Résultat thérapeutique , Échocardiographie transoesophagienne , Échocardiographie , Endocardite/chirurgie
4.
Catheter Cardiovasc Interv ; 104(1): 115-124, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38764320

RÉSUMÉ

BACKGROUND: Transcatheter aortic valve replacement (TAVR) is increasingly being used to treat severe aortic stenosis in younger patients. Accordingly, lifetime management regarding future reintervention and coronary access is a concern. AIMS: To assess the impact of commissural alignment on ACURATE neo2 transcatheter aortic valve (TAV) performance. METHODS: COMALIGN-neo2 was an observational, retrospective study enrolling consecutive TAVR patients treated with the ACURATE neo2 (October 2021 to October 2022). The degree of commissural (mis)-alignment (CMA) with the native aortic valve commissures was determined and transvalvular gradient, effective orifice area, patient-prosthesis mismatch (PPM), and aortic regurgitation (AR) were assessed. RESULTS: Among 825 patients, the mean age was 80.7 years and 42% were female. Commissural alignment was achieved in 60% of cases; mild (26%), moderate (9%), and severe misalignment (5%) were found less often. Severe PPM occurred more frequently in patients with severe CMA (14.7%) compared to aligned valves (p = 0.034). By multivariate analysis, severe CMA (odds ratio [OR]: 3.12, 95% confidence interval [CI] [1.09-8.90]; p = 0.033) and lack of postdilatation (OR: 3.85, [1.33-11.1]; p = 0.012) were associated with severe PPM. Higher rates of ≥mild AR (51.4%) were found in TAVs implanted with severe CMA compared to aligned (34.3%), mildly (38.1%) or moderately (36.0%) misaligned TAVs (p = 0.030). Multivariate analysis identified severe CMA (OR: 2.05, [1.05-4.02]; p = 0.037) to be an independent predictor of ≥mild AR. CONCLUSIONS: COMALIGN-neo2 is the largest study to date assessing the impact of commissural alignment on acute TAV performance. Severe CMA with the ACURATE neo2 platform was associated with worse valve hemodynamics and increased risk for mild AR.


Sujet(s)
Insuffisance aortique , Sténose aortique , Valve aortique , Prothèse valvulaire cardiaque , Hémodynamique , Conception de prothèse , Récupération fonctionnelle , Remplacement valvulaire aortique par cathéter , Humains , Femelle , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Études rétrospectives , Mâle , Sténose aortique/physiopathologie , Sténose aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sujet âgé de 80 ans ou plus , Sujet âgé , Valve aortique/physiopathologie , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Résultat thérapeutique , Insuffisance aortique/physiopathologie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Facteurs de risque , Indice de gravité de la maladie , Facteurs temps
5.
Catheter Cardiovasc Interv ; 104(1): 145-154, 2024 Jul.
Article de Anglais | MEDLINE | ID: mdl-38764317

RÉSUMÉ

BACKGROUND: Data using real-world assessments of aortic regurgitation (AR) severity to identify rates of Heart Valve Team evaluation and aortic valve replacement (AVR), as well as mortality among untreated patients, are lacking. The present study assessed these trends in care and outcomes for real-world patients with documented AR. METHODS: Using a deidentified data set (January 2018-March 2023) representing 1,002,853 patients >18 years of age from 25 US institutions participating in the egnite Database (egnite, Inc.) with appropriate permissions, patients were classified by AR severity in echocardiographic reports. Rates of evaluation by the Heart Valve Team, AVR, and all-cause mortality without AVR were examined using Kaplan-Meier estimates and compared using the log-rank test. RESULTS: Within the data set, 845,113 patients had AR severity documented. For moderate-to-severe or severe AR, respectively, 2-year rates (95% confidence interval) of evaluation by the Heart Valve Team (43.5% [41.7%-45.3%] and 65.4% [63.3%-67.4%]) and AVR (19.4% [17.6%-21.1%] and 46.5% [44.2%-48.8%]) were low. Mortality at 2 years without AVR increased with greater AR severity, up to 20.7% for severe AR (p < 0.001). In exploratory analyses, 2-year mortality for untreated patients with left ventricular end-systolic dimension index > 25 mm/m2 was similar for moderate (34.3% [29.2%-39.1%]) and severe (37.2% [24.9%-47.5%]) AR. CONCLUSIONS: Moderate or greater AR is associated with poor clinical outcomes among untreated patients at 2 years. Rates of Heart Valve Team evaluation and AVR were low for those with moderate or greater AR, suggesting that earlier referral to the Heart Valve Team could be beneficial.


Sujet(s)
Insuffisance aortique , Valve aortique , Bases de données factuelles , Implantation de valve prothétique cardiaque , Indice de gravité de la maladie , Humains , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/mortalité , Insuffisance aortique/physiopathologie , Insuffisance aortique/chirurgie , Mâle , Femelle , Études rétrospectives , Sujet âgé , Facteurs temps , États-Unis/épidémiologie , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Valve aortique/physiopathologie , Résultat thérapeutique , Facteurs de risque , Adulte d'âge moyen , Implantation de valve prothétique cardiaque/effets indésirables , Implantation de valve prothétique cardiaque/mortalité , Sujet âgé de 80 ans ou plus , Appréciation des risques
6.
Ann Card Anaesth ; 27(1): 51-52, 2024 Jan 01.
Article de Anglais | MEDLINE | ID: mdl-38722121

RÉSUMÉ

ABSTRACT: The quadricuspid aortic valve is a rare congenital anomaly, usually associated with aortic regurgitation requiring surgical intervention. It may be associated with other congenital anomalies such as coronary anomalies, patent ductus arteriosus, ventricular septal defect, pulmonary stenosis, and subaortic stenosis. The diagnosis is generally established by either transthoracic or transesophageal echocardiography. Herein, we report a case of a 52-year-old woman who was diagnosed to have quadricuspid aortic valve by intraoperative transesophageal echocardiography.


Sujet(s)
Valve aortique , Échocardiographie transoesophagienne , Humains , Femelle , Valve aortique/malformations , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Adulte d'âge moyen , Échocardiographie transoesophagienne/méthodes , Insuffisance aortique/chirurgie , Insuffisance aortique/imagerie diagnostique , Cardiopathies congénitales/imagerie diagnostique , Cardiopathies congénitales/chirurgie
7.
Catheter Cardiovasc Interv ; 103(7): 1093-1100, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38690931

RÉSUMÉ

BACKGROUND: As compared to treatment of aortic stenosis (AS), transcatheter aortic valve replacement (TAVR) using the commercially available valves to treat pure aortic regurgitation (PAR) has a lower device success rate and higher complication rates. AIMS: The study compared the acute results between TAVR using a novel noncoronary sinus pivot implantation (NCPI) method and that using the conventional method, aiming to explore a more optimized and effective operation method for TAVR in PAR. METHODS: PAR patients who underwent TAVR with self-expanding valves in our center from September 2021 to September 2023 were enrolled were divided into the NCPI (group A, N = 16) and conventional method (group B, N = 39) groups. We analyzed the pre-operative evaluation parameters and procedural and postoperative data of the two subgroups. RESULTS: The total patients' mean age was 71.2 ± 8.7 years and most were male (61.8%), with a mean Society of Thoracic Surgeons score of 3.4 ± 1.9%. The device success rate of groups A and B was 100% and 71.8%, respectively. In group B, 48.7% had major adverse cardiac events (MACE); 46.2% patients had permanent pacemaker implantation or valve in valve implantation. None had MACE in group A. The noncoronary sinus implantation depth in NCPI was -1.1 + 1.0 and 4.2 + 3.7 mm in groups A and B (p < 0.001), respectively. CONCLUSIONS: TAVR with a self-expanding valve using the NCPI method had a higher procedure success rate and dramatically low complications than that using the conventional method in PAR patients.


Sujet(s)
Insuffisance aortique , Valve aortique , Prothèse valvulaire cardiaque , Conception de prothèse , Récupération fonctionnelle , Remplacement valvulaire aortique par cathéter , Humains , Mâle , Femelle , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Insuffisance aortique/physiopathologie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Sujet âgé , Résultat thérapeutique , Sujet âgé de 80 ans ou plus , Valve aortique/chirurgie , Valve aortique/physiopathologie , Valve aortique/imagerie diagnostique , Études rétrospectives , Facteurs temps , Facteurs de risque , Adulte d'âge moyen , Complications postopératoires/étiologie , Hémodynamique
8.
JACC Cardiovasc Interv ; 17(14): 1652-1663, 2024 Jul 22.
Article de Anglais | MEDLINE | ID: mdl-38749449

RÉSUMÉ

BACKGROUND: Transcatheter aortic valve replacement (TAVR) in patients with bicuspid aortic valve (BAV) stenosis is technically challenging and is burdened by an increased risk of paravalvular regurgitation (PVR). OBJECTIVES: The aim of this study was to identify the incidence, predictors, and clinical outcomes of PVR after TAVR in Sievers type 1 BAV stenosis. METHODS: Consecutive patients with Sievers type 1 BAV stenosis undergoing TAVR with current-generation transcatheter heart valves (THVs) in 24 international centers were enrolled. PVR was graded as none/trace, mild, moderate, and severe according to echocardiographic criteria. The endpoint of major adverse events (MAEs), defined as a composite of all-cause death, stroke, or hospitalization for heart failure, was assessed at the last available follow-up. RESULTS: A total of 946 patients were enrolled. PVR occurred in 423 patients (44.7%)-mild, moderate, and severe in 387 (40.9%), 32 (3.4%), and 4 (0.4%) patients, respectively. Independent predictors of moderate or severe PVR were a larger virtual raphe ring perimeter (adjusted OR: 1.07; 95% CI: 1.02-1.13), severe annular or left ventricular outflow tract calcification (adjusted OR: 5.21; 95% CI: 1.45-18.77), a self-expanding valve (adjusted OR: 9.01; 95% CI: 2.09-38.86), and intentional supra-annular THV positioning (adjusted OR: 3.31; 95% CI: 1.04-10.54). At a median follow-up of 1.3 years (Q1-Q3: 0.5-2.4 years), moderate or severe PVR was associated with an increased risk of MAEs (adjusted HR: 2.52; 95% CI: 1.24-5.09). CONCLUSIONS: After TAVR with current-generation THVs in Sievers type 1 BAV stenosis, moderate or severe PVR occurred in about 4% of cases and was associated with an increased risk of MAEs during follow-up.


Sujet(s)
Insuffisance aortique , Sténose aortique , Valve aortique , Maladie de la valve aortique bicuspide , Prothèse valvulaire cardiaque , Indice de gravité de la maladie , Remplacement valvulaire aortique par cathéter , Humains , Mâle , Femelle , Facteurs de risque , Sujet âgé , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/mortalité , Insuffisance aortique/physiopathologie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Sténose aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/physiopathologie , Sténose aortique/mortalité , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Valve aortique/malformations , Résultat thérapeutique , Sujet âgé de 80 ans ou plus , Incidence , Facteurs temps , Maladie de la valve aortique bicuspide/chirurgie , Maladie de la valve aortique bicuspide/imagerie diagnostique , Valvulopathies/imagerie diagnostique , Valvulopathies/chirurgie , Valvulopathies/physiopathologie , Europe , Appréciation des risques , Conception de prothèse , Odds ratio , Accident vasculaire cérébral/étiologie , Accident vasculaire cérébral/diagnostic , Défaillance cardiaque/physiopathologie , Défaillance cardiaque/étiologie , Défaillance cardiaque/diagnostic , Études rétrospectives
9.
Ann Card Anaesth ; 27(1): 53-57, 2024 Jan 01.
Article de Anglais | MEDLINE | ID: mdl-38722122

RÉSUMÉ

ABSTRACT: Aortic valve (AV) repair is the desired surgical treatment option for young patients with aortic regurgitation (AR). It is considered as a class I indication for the surgical treatment of severeAR. The success of an AV repair depends on the detailed intraoperative transesophageal echocardiographic (TEE) examination which should fulfil the information required by the surgeon. The objective of this echo round is to describe the role of intraoperative TEE in systematic evaluation of the AV, before and after repair.


Sujet(s)
Insuffisance aortique , Valve aortique , Échocardiographie transoesophagienne , Surveillance peropératoire , Enfant , Humains , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Insuffisance aortique/chirurgie , Insuffisance aortique/imagerie diagnostique , Échocardiographie transoesophagienne/méthodes , Surveillance peropératoire/méthodes
10.
J Cardiothorac Surg ; 19(1): 301, 2024 May 29.
Article de Anglais | MEDLINE | ID: mdl-38812010

RÉSUMÉ

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital anomaly characterized by the presence of four cusps instead of the usual three. It is estimated to occur in less than 0.05% of the population, with Type A (four equal-sized leaflets) accounting for roughly 30% of QAV subtypes. Based on limited clinical series, the usual presentation is progressive aortic valve regurgitation (AR) with symptoms occurring in the fourth to sixth decade of life. Severe aortic valve stenosis (AS) and acute AR are very uncommon. CASE PRESENTATION: We describe two cases of Type A QAV in patients who remained asymptomatic until their seventies with very uncommon presentations: one with severe AS and one with acute, severe AR and flail leaflet. In Case A, a 72-year-old patient with history of moderate AS presents to clinic with progressive exertional dyspnea. During work-up for transcatheter vs. surgical replacement pre-operative computed tomography angiogram (CTA) reveals a quadricuspid aortic valve with severe AS, and the patient undergoes surgical aortic valve replacement. Pre-discharge transthoracic echocardiography (TTE) shows good prosthetic valve function with no gradient or regurgitation. In Case B, a 76-year-old patient is intubated upon arrival to the hospital for acute desaturation, found to have wide open AR on catheterization, and transferred for emergent intervention. Intraoperative TEE reveals QAV with flail leaflet and severe AR. Repair is considered but deferred ultimately due to emergent nature. Post-operative TTE demonstrates good prosthetic valve function with no regurgitation and normal biventricular function. CONCLUSIONS: QAV can present as progressive severe AS and acute AR, with symptoms first occurring in the seventh decade of life. The optimal treatment for QAV remains uncertain. Although aortic valve repair or transcatheter option may be feasible in some patients, aortic valve replacement remains a tenable option.


Sujet(s)
Valve aortique , Sujet âgé , Humains , Valve aortique/malformations , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Insuffisance aortique/chirurgie , Insuffisance aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/imagerie diagnostique , Sténose aortique/diagnostic , Échocardiographie , Implantation de valve prothétique cardiaque
11.
J Am Heart Assoc ; 13(9): e032532, 2024 May 07.
Article de Anglais | MEDLINE | ID: mdl-38686861

RÉSUMÉ

BACKGROUND: This study was performed to determine cusp causes of aortic regurgitation in patients with tricuspid aortic valves without significant aortic dilatation and define cusp pathologies amenable to surgical repair (aortic valve repair [AVr]) versus aortic valve replacement. METHODS AND RESULTS: We retrospectively reviewed surgical reports of consecutive adults with tricuspid aortic valves undergoing surgery for clinically significant aortic regurgitation within a prospective registry from January 2005 to September 2019. Valvular mechanisms were determined by systematic in vivo intraoperative quantification methods. Of 516 patients, 287 (56%) underwent repair (AVr; mean±SD age, 59.9±12.4 years; 81% men) and 229 (44%) underwent replacement (aortic valve replacement; mean±SD age, 62.8±13.8 years [P=0.01 compared to AVr]; 67% men). A single valvular mechanism was present in 454 patients (88%), with cusp prolapse (46%), retraction (24%), and perforation (18%) being the most common. Prolapse involved the right cusp in 86% of cases and was more frequent in men (P<0.001). Two-dimensional transesophageal echocardiography accuracy for predicting mechanisms was 73% to 82% for the right cusp, 55% to 61% for the noncoronary cusp, and 0% for the left-coronary cusp. Cusp prolapse, younger age, and larger patient size were associated with successful AVr (all P<0.03), whereas retraction, perforation, older age, and concomitant mitral repair were associated with aortic valve replacement (all P<0.03). CONCLUSIONS: Right cusp prolapse is the most frequent single valvular mechanism in patients with tricuspid aortic valve aortic regurgitation, followed by cusp retraction and perforation. The accuracy of 2-dimensional transesophageal echocardiography is limited for left and noncoronary cusp mechanistic assessment. Prolapse is associated with successful AVr, whereas retraction and perforation are associated with aortic valve replacement. With systematic intraoperative quantification methods and current surgical techniques, more than half of tricuspid aortic valve aortic regurgitation cases may be successfully repaired.


Sujet(s)
Insuffisance aortique , Valve aortique , Échocardiographie transoesophagienne , Implantation de valve prothétique cardiaque , Humains , Mâle , Insuffisance aortique/chirurgie , Insuffisance aortique/physiopathologie , Insuffisance aortique/imagerie diagnostique , Adulte d'âge moyen , Femelle , Études rétrospectives , Implantation de valve prothétique cardiaque/effets indésirables , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Sujet âgé , Valve atrioventriculaire droite/chirurgie , Valve atrioventriculaire droite/imagerie diagnostique , Valve atrioventriculaire droite/physiopathologie , Résultat thérapeutique , Enregistrements , Annuloplastie de valves cardiaques/méthodes
12.
Int J Cardiol ; 408: 132084, 2024 Aug 01.
Article de Anglais | MEDLINE | ID: mdl-38653434

RÉSUMÉ

BACKGROUND: In congenital aortic valve disease, quantifying aortic regurgitation (AR) varies by the measurement site. Our study aimed to identify the optimal site for AR assessment using 2D and 4D MR flow measurements, with a focus on vortices. METHODS: We retrospectively analysed 31 patients with congenital aortic valve disease, performing 2D and 4D MR flow measurements at the aortic valve, sinotubular junction (STJ), ascending aorta (AAo), and using midpulmonary artery measurements as a reference. We assessed percentage AR and net forward volumes, calculated linear correlations, and plotted Bland-Altman plots. Net forward flow at all aortic sites were correlated with the main pulmonary artery. Differences in AR between 2D and 4D flows were linked to vortices detected by 4D streamlines. RESULTS: The best agreement in % AR between 2D and 4D flows was at the aortic valve (mean difference 4D2D -2.9%, limits of agreement 8.7% to -14.3%; r2 = 0.7). Correlations weakened at STJ and AAo. Vortices in the ascending aorta led to AR overestimation in 2D measurements. Net forward flow at the aortic valve by 4D flow correlated closer with main pulmonary artery than did 2D flow. (Mean difference for 2D and 4D MR flow 7.5 ml and 4.2 ml, respectively). CONCLUSIONS: For congenital aortic valve disease, the most accurate AR quantification occurs at the aortic valve using 2D and 4D MR flow. Notably, vortices in the ascending aorta can result in AR overestimation with 2D MR flow.


Sujet(s)
Insuffisance aortique , Humains , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/physiopathologie , Études rétrospectives , Femelle , Mâle , Adulte , Valve aortique/imagerie diagnostique , Valve aortique/malformations , Valve aortique/physiopathologie , IRM dynamique/méthodes , Vitesse du flux sanguin/physiologie , Adulte d'âge moyen , Adolescent , Jeune adulte , Enfant , Maladie de la valve aortique/imagerie diagnostique
13.
Surg Innov ; 31(3): 256-262, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38565982

RÉSUMÉ

OBJECTIVE: In this case report, the auxiliary role of deep learning and 3-dimensional printing technology in the perioperative period was discussed to guide transcatheter aortic valve replacement and coronary stent implantation simultaneously. CASE PRESENTATION: A 68-year-old man had shortness of breath and chest tightness, accompanied by paroxysmal nocturnal dyspnea, 2 weeks before presenting at our hospital. Echocardiography results obtained in the outpatient department showed severe aortic stenosis combined with regurgitation and pleural effusion. The patient was first treated with closed thoracic drainage. After 800 mL of pleural effusion was collected, the patient's symptoms were relieved and he was admitted to the hospital. Preoperative transthoracic echocardiography showed severe bicuspid aortic valve stenosis combined with calcification and aortic regurgitation (mean pressure gradient, 42 mmHg). Preoperative computed tomography results showed a type I bicuspid aortic valve with severe eccentric calcification. The leaflet could be seen from the left coronary artery plane, which indicated an extremely high possibility of coronary obstruction. After preoperative imaging assessment, deep learning and 3-dimensional printing technology were used for evaluation and simulation. Guided transcatheter aortic valve replacement and a coronary stent implant were completed successfully. Postoperative digital subtraction angiography showed that the bioprosthesis and the chimney coronary stent were in ideal positions. Transesophageal echocardiography showed normal morphology without paravalvular regurgitation. CONCLUSION: The perioperative guidance of deep learning and 3-dimensional printing are of great help for surgical strategy formulation in patients with severe bicuspid aortic valve stenosis with calcification and high-risk coronary obstruction.


Sujet(s)
Sténose aortique , Apprentissage profond , Impression tridimensionnelle , Remplacement valvulaire aortique par cathéter , Humains , Remplacement valvulaire aortique par cathéter/méthodes , Mâle , Sujet âgé , Sténose aortique/chirurgie , Sténose aortique/imagerie diagnostique , Endoprothèses , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/malformations , Insuffisance aortique/chirurgie , Insuffisance aortique/imagerie diagnostique
14.
Echocardiography ; 41(4): e15817, 2024 Apr.
Article de Anglais | MEDLINE | ID: mdl-38648213

RÉSUMÉ

BACKGROUND: Quadricuspid aortic valve (QAV) is a rare congenital disease. The clinical characteristics of this disease remain unclear except for those in relatively young patients reported from tertiary referral hospitals. The aim of this study was to determine the clinical features of QAV in a regional population. METHODS AND RESULTS: We retrospectively investigated 25 340 consecutive patients over middle age (median age, 73 (IQR 65-80) years; range, 45-102 years) who underwent transthoracic echocardiography (TTE) at our institute during the period from April 2008 to December 2023. Eight (0.032%) of the patients (median age, 65 years; range, 47-91 years) were diagnosed with QAV. Six patients suffered from aortic regurgitation (AR), and one patient had mild aortic stenosis at the time of QAV diagnosis. Two patients who had severe AR at referral underwent aortic valve surgery. The severity of AR in the other patients was moderate or less. During a median follow-up period of 27 months (range, 1-171 months), none of the patients other than above two patients had cardiac events. One patient died from a non-cardiac cause at 94 years of age. CONCLUSIONS: Patients diagnosed with QAV after middle age, who do not exhibit severe valve insufficiency at the time of diagnosis, may not experience worse clinical outcomes. However, further research is required for a better understanding of the long-term outcomes.


Sujet(s)
Valve aortique , Échocardiographie , Humains , Femelle , Mâle , Valve aortique/malformations , Valve aortique/imagerie diagnostique , Valve aortique/chirurgie , Sujet âgé , Études rétrospectives , Adulte d'âge moyen , Sujet âgé de 80 ans ou plus , Échocardiographie/méthodes , Insuffisance aortique/chirurgie , Insuffisance aortique/imagerie diagnostique , Cardiopathies congénitales/imagerie diagnostique , Études de suivi
15.
Catheter Cardiovasc Interv ; 103(6): 1015-1022, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38577931

RÉSUMÉ

BACKGROUND: Previous studies have documented a high rate of implantation success with the ACURATE neo2 valve, as well as a reduction in paravalvular leak (PVL) compared to its predecessor, the ACURATE neo. However, there are no studies that have reviewed and compared the long-term clinical and hemodynamic outcomes of these patients. AIMS: This study aimed to evaluate the results of the ACURATE neo transcatheter aortic valve in a real-world context, and to compare the results of the outcomes of both generations of this device (ACURATE neo and ACURATE neo2), with a specific focus on procedural success, safety, and long-term effectiveness. METHODS: A prospective study including all consecutive patients treated with the ACURATE neo device in seven hospitals was conducted (Clinical Trials Identification Number: NCT03846557). The primary endpoint consisted of a composite of adverse events, including mortality, aortic insufficiency, and other procedural complications. As the second-generation device (ACURATE neo2) replaced the ACURATE neo during the study period, hemodynamic and clinical results before admission, at 30 days, and at 1 year of follow-up were compared between the two generations. RESULTS: A total of 296 patients underwent transcatheter aortic valve implantation with the ACURATE device, with 178 patients receiving the ACURATE neo and 118 patients receiving the ACURATE neo2. In the overall population, the absence of device success occurred in 14.5%. The primary reason for the absence of device success was the presence of para-valvular regurgitation ≥ 2. There were no instances of coronary occlusions, valve embolization, annulus rupture, or procedural deaths. ACURATE neo2 was associated with a significantly higher device success rate (91.7% vs. 82%, p = 0.04), primarily due to a significantly lower rate of para-valvular regurgitation, which remained significant at 1 year. CONCLUSION: The use of ACURATE neo and neo2 transcatheter aortic valves is associated with satisfactory clinical results and an extremely low rate of complications. The ACURATE neo2 enables a significantly higher device success rate, primarily attributed to a significant reduction in the rate of PVL.


Sujet(s)
Sténose aortique , Valve aortique , Prothèse valvulaire cardiaque , Hémodynamique , Conception de prothèse , Enregistrements , Remplacement valvulaire aortique par cathéter , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Valve aortique/chirurgie , Valve aortique/physiopathologie , Valve aortique/imagerie diagnostique , Insuffisance aortique/physiopathologie , Insuffisance aortique/étiologie , Insuffisance aortique/imagerie diagnostique , Sténose aortique/chirurgie , Sténose aortique/physiopathologie , Sténose aortique/imagerie diagnostique , Complications postopératoires , Études prospectives , Récupération fonctionnelle , Facteurs de risque , Espagne , Facteurs temps , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
16.
Catheter Cardiovasc Interv ; 103(6): 1074-1077, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38577923

RÉSUMÉ

Transcatheter aortic valve implantation (TAVI) has traditionally been indicated for the treatment of aortic stenosis. However, in this case report, we describe a successful TAVI procedure in a 46-year-old male patient who had previously undergone David aortic valve-sparing aortic root replacement for type 1 aortic dissection. The patient presented with aortic valve insufficiency 4 years after the initial surgery and was subsequently treated with a 34 mm Medtronic CoreValve Evolut R prosthesis via TAVI. This case highlights the feasibility of TAVI as a viable treatment option for postoperative aortic valve insufficiency in patients with prior ascending aortic or aortic arch surgery.


Sujet(s)
, Insuffisance aortique , Valve aortique , Implantation de prothèses vasculaires , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Humains , Mâle , /chirurgie , /imagerie diagnostique , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/étiologie , Insuffisance aortique/chirurgie , Insuffisance aortique/physiopathologie , Adulte d'âge moyen , Remplacement valvulaire aortique par cathéter/effets indésirables , Remplacement valvulaire aortique par cathéter/instrumentation , Résultat thérapeutique , Implantation de prothèses vasculaires/instrumentation , Implantation de prothèses vasculaires/effets indésirables , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Conception de prothèse , Prothèse vasculaire , Anévrysme de l'aorte thoracique/chirurgie , Anévrysme de l'aorte thoracique/imagerie diagnostique , Anévrysme de l'aorte/chirurgie , Anévrysme de l'aorte/imagerie diagnostique , Aortographie
17.
Catheter Cardiovasc Interv ; 103(7): 1101-1110, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38532517

RÉSUMÉ

Structural valve deterioration after aortic root replacement (ARR) surgery may be treated by transcatheter valve-in-valve (ViV-TAVI) intervention. However, several technical challenges and outcomes are not well described. The aim of the present review was to analyze the outcomes of ViV-TAVI in deteriorated ARR. This review included studies reporting any form of transcatheter valvular intervention in patients with a previous ARR. All forms of ARR were considered, as long as the entire root was replaced. Pubmed, ScienceDirect, SciELO, DOAJ, and Cochrane library databases were searched until September 2023. Overall, 86 patients were included from 31 articles that met our inclusion criteria out of 741 potentially eligible studies. In the entire population, the mean time from ARR to reintervention was 11.0 years (range: 0.33-22). The most frequently performed techniques/grafts for ARR was homograft (67.4%) and the main indication for intervention was aortic regurgitation (69.7%). Twenty-three articles reported no postoperative complications. Six (7.0%) patients required permanent pacemaker implantation (PPI) after the ViV-TAVI procedure, and 4 (4.7%) patients had a second ViV-TAVI implant. There were three device migrations (3.5%) and 1 stroke (1.2%). Patients with previous ARR present a high surgical risk. ViV-TAVI can be considered in selected patients, despite unique technical challenges that need to be carefully addressed according to the characteristics of the previous surgery and on computed tomography analysis.


Sujet(s)
Valve aortique , Prothèse valvulaire cardiaque , Remplacement valvulaire aortique par cathéter , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Femelle , Humains , Mâle , Adulte d'âge moyen , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Valve aortique/physiopathologie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/physiopathologie , Insuffisance aortique/chirurgie , Insuffisance aortique/étiologie , Prothèse vasculaire , Implantation de prothèses vasculaires/instrumentation , Implantation de prothèses vasculaires/effets indésirables , Entraînement électrosystolique , Implantation de valve prothétique cardiaque/instrumentation , Implantation de valve prothétique cardiaque/effets indésirables , Défaillance de prothèse , Récupération fonctionnelle , Appréciation des risques , Facteurs de risque , Facteurs temps , Remplacement valvulaire aortique par cathéter/instrumentation , Remplacement valvulaire aortique par cathéter/effets indésirables , Résultat thérapeutique
18.
Int J Cardiovasc Imaging ; 40(5): 1049-1057, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38519822

RÉSUMÉ

PURPOSE: This study investigated discordance between echocardiography (echo) and cardiac magnetic resonance (CMR) measurements of the left ventricle (LV) in pediatric patients with aortic and/or mitral regurgitation (AR/MR). METHODS: Retrospective cohort study of pediatric patients. The cohorts were comprised of patients with AR/MR vs. non-AR/MR. Left ventricular end diastolic volume (LVEDV) by CMR and left ventricular internal diameter diastolic (LVIDd) by echo were obtained from clinical reports then echo images were reviewed to remeasure LVEDV by bullet method. Left ventricular internal diameter systolic (LVIDs) and left ventricular ejection fraction (LVEF) measurements by echo and LVEF by CMR were obtained from clinical reports. Fractional shortening (FS%) was recalculated. Z-scores were calculated using normative data. Correlation between echo and CMR LV measurements was assessed using correlation coefficients. Bland-Altman plots assessed bias between imaging modalities. Receiver operator characteristic (ROC) analysis was performed for detection of LV enlargement and LV dysfunction. RESULTS: AR/MR patients had greater discrepancy in LV size interpretation by Z-score compared to non-AR/MR patients. This discrepancy persisted when the bullet method short axis measurements were incorporated. There was negative bias in echo-based measurements compared to CMR. The diagnostic performance of echo in identifying moderate LV enlargement was worse for AR/MR pediatrics patients. CONCLUSION: The discordant interpretation of LV size by echo compared to CMR is worse in pediatric patients with AR/MR when compared to patients without AR/MR even when short axis measurements are incorporated. This finding suggests non-uniform geometrical changes in the LV as it enlarges due to AR/MR.


Sujet(s)
Insuffisance aortique , Ventricules cardiaques , Insuffisance mitrale , Valeur prédictive des tests , Débit systolique , Fonction ventriculaire gauche , Humains , Études rétrospectives , Femelle , Enfant , Mâle , Reproductibilité des résultats , Adolescent , Enfant d'âge préscolaire , Insuffisance mitrale/physiopathologie , Insuffisance mitrale/imagerie diagnostique , Ventricules cardiaques/imagerie diagnostique , Ventricules cardiaques/physiopathologie , Insuffisance aortique/imagerie diagnostique , Insuffisance aortique/physiopathologie , Facteurs âges , IRM dynamique , Nourrisson , Dysfonction ventriculaire gauche/imagerie diagnostique , Dysfonction ventriculaire gauche/physiopathologie , Hypertrophie ventriculaire gauche/imagerie diagnostique , Hypertrophie ventriculaire gauche/physiopathologie
19.
Circ Cardiovasc Interv ; 17(5): e013898, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38533653

RÉSUMÉ

BACKGROUND: Acute aortic regurgitation is life-threatening with few nonsurgical options for immediate stabilization. We propose Trans-Aortic Balloon to Ease Regurgitation Applying Counter-Pulsation (TABERNACL), a simple, on-table temporary valve using commercially available equipment to temporize acute severe aortic regurgitation. METHODS: We hypothesize that an appropriately sized commercial balloon dilatation catheter-straddling the aortic annulus and connected to a counterpulsation console-can serve as a temporizing valve to restore hemodynamic stability in acute aortic regurgitation. We performed benchtop testing of valvuloplasty, angioplasty, and sizing balloons as counterpulsation balloons. TABERNACL was assessed in vivo in a porcine model of acute aortic regurgitation (n=8). We also tested a static undersized, continuously inflated transvalvular balloon as a spacer intended physically to obstruct the regurgitant orifice. RESULTS: Benchtop testing identified that Tyshak II and PTS sizing (NuMed Braun) balloon catheters performed adequately as temporary valves (ie, complete inflation and deflation with each cycle) and resisted fatigue, in contrast to others. When TABERNACL was used in the acute severe regurgitation animals, there was immediate hemodynamic improvement, with a significant 35% increase in diastolic aortic pressure by 16 mm Hg ([95% CI, 7-25] P=0.0056), 34% reduction in left ventricular end-diastolic pressure by -7 mm Hg ([95% CI, -10 to -5] P=0.0006), improvement in the aortic diastolic index by 0.28 ([95% CI, 0.18-0.39] P=0.0009), and reversal of electrocardiographic myocardial ischemia. As an alternative, static balloon inflation across the aortic valve stabilized regurgitation hemodynamics at the expense of a new aortic gradient and caused excessive ectopy from balloon movement in the left ventricular outflow tract. CONCLUSIONS: TABERNACL improves hemodynamics and reduces coronary ischemia by electrocardiography in animals with acute severe aortic regurgitation. TABERNACL valves obstruct the diastolic regurgitant orifice without systolic obstruction. This may prove a lifesaving bridge to definitive valve replacement therapy.


Sujet(s)
Insuffisance aortique , Valvuloplastie par ballonnet , Modèles animaux de maladie humaine , Hémodynamique , Animaux , Hémodynamique/effets des médicaments et des substances chimiques , Insuffisance aortique/physiopathologie , Insuffisance aortique/étiologie , Insuffisance aortique/imagerie diagnostique , Sus scrofa , Valve aortique/physiopathologie , Valve aortique/chirurgie , Valve aortique/imagerie diagnostique , Conception d'appareillage , Récupération fonctionnelle , Maladie aigüe , Sondes cardiaques , Facteurs temps , Indice de gravité de la maladie , Fonction ventriculaire gauche/effets des médicaments et des substances chimiques