RÉSUMÉ
AIMS: Intraoperative complications in cataract surgery are more common in diabetic patients. Solving aphakia in these circumstances remains a challenge, as the scleral structure has been shown to be different in diabetes. This study aims to analyze the role of a secondary sutureless scleral intraocular lens (IOL) flanged fixation in diabetic patients without capsular support and to compare the anatomical and functional outcomes using a 30 gauge (G) ultrathin wall needle vs. a 27G needle. METHODS: Retrospective, observational cohort study. 105 eyes (105 patients) who underwent PPV with secondary IOL fixation using a sutureless 27G (n = 51) or a 30G ultrathin wall (UTW) needle technique (n = 54) and had a 24 months postoperative follow up. Consecutive patients' records were reviewed for lens stability and centration parameters, intra- and postoperative complications at 7 days, 1, 3, 6, 12, and 24 months after surgery. Correlations between outcome measures and needle size (27G vs. 30G UTW) were analyzed. RESULTS: IOL displacement occurred in 30 patients (41.2%) in the 27G group and did not occur in the 30G UTW needle group (p < 0.001). Mean time until IOL displacement was 10.5 ± 7.0 months (range: 7 days-24 months). IOL centricity was significantly better in the 30G ultrathin wall needle group compared to 27 G (p = 0.001). Additional surgical interventions were necessary only in the 27G group (n = 14). CONCLUSIONS: Sutureless IOL flanged technique using a 30G UTW needle is more predictable and has less complications in aphakic diabetic patients, compared to a 27G needle technique.
Sujet(s)
Diabète/chirurgie , Rétinopathie diabétique/chirurgie , Pose d'implant intraoculaire/instrumentation , Aiguilles , Interventions chirurgicales sans suture/instrumentation , Adulte , Sujet âgé , Aphakie/épidémiologie , Aphakie/chirurgie , Argentine/épidémiologie , Études de cohortes , Diabète/épidémiologie , Rétinopathie diabétique/épidémiologie , Conception d'appareillage , Femelle , Études de suivi , Humains , Pose d'implant intraoculaire/effets indésirables , Pose d'implant intraoculaire/méthodes , Lentilles intraoculaires , Mâle , Adulte d'âge moyen , Aiguilles/effets indésirables , Complications postopératoires/épidémiologie , Complications postopératoires/étiologie , Études rétrospectives , Sclère/chirurgie , Interventions chirurgicales sans suture/effets indésirables , Interventions chirurgicales sans suture/méthodes , Acuité visuelleRÉSUMÉ
INTRODUCTION: The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. METHODS: The data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017. RESULTS: Cardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A. CONCLUSION: The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.
Sujet(s)
Bioprothèse/effets indésirables , Implantation de valve prothétique cardiaque/effets indésirables , Prothèse valvulaire cardiaque/effets indésirables , Complications postopératoires/étiologie , Thrombopénie/étiologie , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Valve aortique/chirurgie , Pontage cardiopulmonaire/effets indésirables , Constriction , Femelle , Implantation de valve prothétique cardiaque/méthodes , Humains , Mâle , Adulte d'âge moyen , Numération des plaquettes , Conception de prothèse , Études rétrospectives , Interventions chirurgicales sans suture/effets indésirables , Interventions chirurgicales sans suture/méthodes , Facteurs temps , Résultat thérapeutiqueRÉSUMÉ
Abstract Introduction: The incidence of postoperative thrombocytopenia after aortic valve replacement (AVR) with the Perceval S Sutureless bioprosthesis remains unclear. The aim of this study was to report thrombocytopenia associated with the use of sutureless AVR. Methods: The data was collected retrospectively for patients who had isolated AVR with sutureless Perceval S valve (Group A: 72 patients) and was compared with patients who underwent isolated sutured AVR with Perimount Magna Ease Bioprosthesis (Group B: 101 patients) in our institution between June 2014 and January 2017. Results: Cardiopulmonary bypass and cross-clamp time were significantly shorter in group A. Maximum drop in platelet count was 58% mean (day 2.3) in group A versus 44% mean (day 1.7) in group B (P=0.0001). Absolute platelet count on postoperative day 1-6 in group A was significantly less than in group B (P≤0.05). Platelet count recovered to preoperative value in 44% patients in group B versus only in 26% patients in group A at discharge (P=0.018). Moderate thrombocytopenia occurs more often in group A (41% vs. 26%) (P=0.008) while severe thrombocytopenia (<50 x 109) was observed in 6% in group A but never in group B. Platelets (P=0.007) and packed red blood cells (P=0.009) transfusion was significantly higher in the group A. Conclusion: The implantation of sutureless Perceval aortic valves was associated with a significant drop in platelet count postoperatively with slow recovery and higher platelets and packed red blood cells transfusion requirements. A prospective randomised trial is needed to confirm our findings.