Résultats 1 - 20 de 9.724
Filtrer
1.
BMC Anesthesiol ; 24(1): 221, 2024 Jul 03.
Article de Anglais | MEDLINE | ID: mdl-38961365

RÉSUMÉ

BACKGROUND: This study aimed to evaluate the accuracy of ankle blood pressure measurements in relation to invasive blood pressure in the lateral position. METHODS: This prospective observational study included adult patients scheduled for elective non-cardiac surgery under general anesthesia in the lateral position. Paired radial artery invasive and ankle noninvasive blood pressure readings were recorded in the lateral position using GE Carescape B650 monitor. The primary outcome was the ability of ankle mean arterial pressure (MAP) to detect hypotension (MAP < 70 mmHg) using area under the receiver operating characteristic curve (AUC) analysis. The secondary outcomes were the ability of ankle systolic blood pressure (SBP) to detect hypertension (SBP > 140 mmHg) as well as bias (invasive measurement - noninvasive measurement), and agreement between the two methods using the Bland-Altman analysis. RESULTS: We analyzed 415 paired readings from 30 patients. The AUC (95% confidence interval [CI]) of ankle MAP for detecting hypotension was 0.88 (0.83-0.93). An ankle MAP of ≤ 86 mmHg had negative and positive predictive values (95% CI) of 99 (97-100)% and 21 (15-29)%, respectively, for detecting hypotension. The AUC (95% CI) of ankle SBP to detect hypertension was 0.83 (0.79-0.86) with negative and positive predictive values (95% CI) of 95 (92-97)% and 36 (26-46)%, respectively, at a cutoff value of > 144 mmHg. The mean bias between the two methods was - 12 ± 17, 3 ± 12, and - 1 ± 11 mmHg for the SBP, diastolic blood pressure, and MAP, respectively. CONCLUSION: In patients under general anesthesia in the lateral position, ankle blood pressure measurements are not interchangeable with the corresponding invasive measurements. However, an ankle MAP > 86 mmHg can exclude hypotension with 99% accuracy, and an ankle SBP < 144 mmHg can exclude hypertension with 95% accuracy.


Sujet(s)
Anesthésie générale , Cheville , Mesure de la pression artérielle , Humains , Femelle , Anesthésie générale/méthodes , Mâle , Études prospectives , Adulte d'âge moyen , Mesure de la pression artérielle/méthodes , Cheville/vascularisation , Sujet âgé , Oscillométrie/méthodes , Pression sanguine/physiologie , Hypertension artérielle/physiopathologie , Hypertension artérielle/diagnostic , Hypotension artérielle/diagnostic , Hypotension artérielle/physiopathologie , Adulte , Positionnement du patient/méthodes
2.
Sheng Wu Yi Xue Gong Cheng Xue Za Zhi ; 41(3): 430-438, 2024 Jun 25.
Article de Chinois | MEDLINE | ID: mdl-38932527

RÉSUMÉ

Monitoring airway impedance has significant clinical value in accurately assessing and diagnosing pulmonary function diseases at an early stage. To address the issue of large oscillator size and high power consumption in current pulmonary function devices, this study adopts a new strategy of expiration-driven oscillation. A lightweight and low-power airway impedance monitoring system with integrated sensing, control circuitry, and dynamic feedback system, providing visual feedback on the system's status, was developed. The respiratory impedance measurement experiments and statistical comparisons indicated that the system could achieve stable measurement of airway impedance at 5 Hz. The frequency spectrum curves of respiratory impedance ( R and X) showed consistent trends with those obtained from the clinical pulmonary function instrument, specifically the impulse oscillometry system (IOS). The differences between them were all less than 1.1 cm H 2O·s/L. Additionally, there was a significant statistical difference in the respiratory impedance R5 between the exercise and rest groups, which suggests that the system can measure the variability of airway resistance parameters during exercise. Therefore, the impedance monitoring system developed in this study supports subjects in performing handheld, continuous measurements of dynamic changes in airway impedance over an extended period of time. This research provides a foundation for further developing low-power, portable, and even wearable devices for dynamic monitoring of pulmonary function.


Sujet(s)
Résistance des voies aériennes , Impédance électrique , Oscillométrie , Tests de la fonction respiratoire , Humains , Oscillométrie/instrumentation , Monitorage physiologique/instrumentation , Monitorage physiologique/méthodes , Tests de la fonction respiratoire/instrumentation , Expiration/physiologie , Conception d'appareillage , Exercice physique
3.
BMC Pulm Med ; 24(1): 270, 2024 Jun 06.
Article de Anglais | MEDLINE | ID: mdl-38844887

RÉSUMÉ

INTRODUCTION: The evaluation of the asthmatic patient is usually based on clinical and functional parameters that do not necessarily evidence the degree of airway inflammation. The aim of this study was to analyze whether clinical scores (CS) correlate with spirometry (S), impulse oscillometry (IO) and FeNO, in severe asthmatic children. MATERIAL AND METHODS: A multicentric, prospective, cross-sectional study was conducted over a 12-month period. All SA patients (6-18 years old) followed-up in the Pulmonology Department were recruited. CS, FeNO measurements, IO and S were consecutively performed on the same day. Asthma control was ascertained using ACT and GINAq. A cut-off value of ≥ 25 parts per billion (ppb) was used to define airway inflammation. RESULTS: Eighty-one patients were included. ACT: 75% (n 61) were controlled; GINAq: 44.5% (n 36) were controlled; 39.5% (n 32) were partly controlled, and 16% (n 13) were uncontrolled. FeNO had a median value of 24 ppb (IQR 14-41); FeNO ≥ 25 ppb was observed in 49% of patients (n 39). ROC AUC for FeNO vs. ACT was 0.71 (95%CI 0.57-0.86), PPV 0.47, NPV 0.87, SE 0.61, SP 0.80; FeNO vs. GINAq was ROC AUC 0.69 (95%CI 0.54-0.85), PPV 0.34, NPV 0.91, SE 0.62, SP 0.77; Youden cut-off FeNO > 39 ppb for both CS. CONCLUSION: In severe asthmatic children, current symptoms control as evidenced by ACT and GINA correlates with low FeNO values. Clinical scores showed good correlation with airway inflammation.


Sujet(s)
Asthme , Monoxyde d'azote , Oscillométrie , Indice de gravité de la maladie , Spirométrie , Humains , Asthme/diagnostic , Asthme/physiopathologie , Enfant , Femelle , Mâle , Oscillométrie/méthodes , Études transversales , Études prospectives , Adolescent , Monoxyde d'azote/analyse , Monoxyde d'azote/métabolisme , Courbe ROC
4.
J Assoc Physicians India ; 72(5): 29-35, 2024 May.
Article de Anglais | MEDLINE | ID: mdl-38881107

RÉSUMÉ

BACKGROUND: Spirometry is used extensively, but airway oscillometry is gaining acceptance for evaluating obstructive airway disorders. Moderate persistent asthma requires daily treatment with inhaled corticosteroids (ICS). MATERIALS AND METHODS: We aimed to examine the relationship between airway oscillometry and lung volumes, which are the markers of lung physiology in obstructive airway disease and spirometry in the real-world clinical setting. A total of 72 adults with moderate persistent asthma followed up in our outpatient department from November 2021 to August 2022, and their clinical details and tests of spirometry, forced oscillation technique (FOT), and lung volumes by body plethysmography (BP) performed before and after bronchodilator administration were analyzed. RESULTS: The mean age of the study population was 40 years, and the majority (57%) were females. FOT detected airflow limitation in 12 of the 31 patients with normal spirometry. BP detected abnormalities in more patients than both spirometry and FOT (91.6 vs 73.6%, p < 0.001). Respiratory resistance 5 (R5) had a negative correlation with functional residual capacity (FRC) and total lung capacity (TLC). Reactance 5 (X5) correlated positively with inspiratory capacity (IC) and TLC and negatively with reserve volume (RV)/TLC ratio. A positive correlation was found between IC/TLC% and postbronchodilator X5 and between R5 and 19 and RV/TLC. R5 had a negative and X5 had a positive correlation with forced expiratory volume in 1 second (FEV1), forced vital capacity (FVC), FEV1/FVC, and maximal mid expiratory flow rates (MMEF). ∇X5 had a negative correlation with FEV1, MMEF, and FEV1/FVC. Spirometry detected postbronchodilator responsiveness in more patients than FOT when only the R5 criterion was used and in a comparable number when the X5 criterion was added. ∇X5 and R5-R19/R5 declined significantly after bronchodilators. CONCLUSION: We concluded that there is a moderate correlation between FOT and spirometry and lung volumes by BP. FOT and spirometry should be used together to identify airflow obstruction and postbronchodilator responsiveness in asthma. Lung volumes by BP identify more abnormalities in adults with asthma than both spirometry and FOT. Thresholds to define postbronchodilator responsiveness (PBDR) for ∇X5 and R5-R19 need to be defined.


Sujet(s)
Asthme , Pléthysmographie du corps entier , Spirométrie , Humains , Asthme/traitement médicamenteux , Asthme/physiopathologie , Asthme/diagnostic , Femelle , Adulte , Mâle , Spirométrie/méthodes , Adulte d'âge moyen , Pléthysmographie du corps entier/méthodes , Oscillométrie/méthodes , Bronchodilatateurs/usage thérapeutique , Bronchodilatateurs/administration et posologie , Mesure des volumes pulmonaires/méthodes , Poumon/physiopathologie
5.
Vet J ; 305: 106137, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38759724

RÉSUMÉ

Arterial blood pressure (ABP) is often measured with oscillometry during anaesthesia. Changing the height of the measuring cuff with respect to the level of the heart is known to affect oscillometry accuracy in some species; however, this effect has not been investigated in cats. The objective of this study was to determine the effects of raising and lowering the measuring cuff from standard position (level of the heart) on ABP, measured with PetMAP, in anaesthetised cats. ABP readings were obtained from 29 cats with the cuff at standard position (baseline), and 5 cm above and below the heart. The end-tidal isoflurane concentrations were maintained constant during data acquisition. There were no differences between baseline values and those measured below the heart, while ABP measured above the heart was consistently lower than baseline for both the thoracic and pelvic limbs (P < 0.001), with absolute differences of 8.2 (2.5 - 14) mmHg and 6.5 (3.0 - 15.0) mmHg, respectively. Systolic ABP readings at the pelvic limb were consistently higher than those at the thoracic limb at standard position (112 ± 26 versus 103 ± 21 mmHg, p = 0.010), above (106 ± 22 versus 95 ± 20 mmHg, p = 0.003), and below the heart (116 ± 26 versus 107 ± 22 mmHg, p = 0.011). This study shows that raising the cuff by 5 cm above the heart, which may become necessary during procedural positioning, results in clinically significant underestimation of ABP measured with PetMAP.


Sujet(s)
Mesure de la pression artérielle , Oscillométrie , Animaux , Chats/physiologie , Mesure de la pression artérielle/médecine vétérinaire , Mesure de la pression artérielle/méthodes , Mesure de la pression artérielle/instrumentation , Oscillométrie/médecine vétérinaire , Oscillométrie/instrumentation , Mâle , Femelle , Pression artérielle , Anesthésie/médecine vétérinaire , Membres , Pression sanguine
6.
J Hypertens ; 42(7): 1235-1247, 2024 Jul 01.
Article de Anglais | MEDLINE | ID: mdl-38690876

RÉSUMÉ

There is little quantitative clinical data available to support blood pressure measurement accuracy during cuff inflation. In this study of 35 male and 5 female lightly anaesthetized subjects aged 64.1 ±â€Š9.6 years, we evaluate and compare the performance of both the oscillometric ratio and gradient methods during cuff deflation and cuff inflation with reference to intra-arterial measurements. We show that the oscillometric waveform envelopes (OWE), which are key to both methods, exhibit significant variability in both shape and smoothness leading to at least 15% error in the determination of mean pressure (MP). We confirm the observation from our previous studies that K1 Korotkoff sounds underestimate systolic blood pressure (SBP) and note that this underestimation is increased during cuff inflation. The estimation of diastolic blood pressure (DBP) is generally accurate for both the ratio and the gradient method, with the latter showing a significant increase during inflation. Since the gradient method estimates SBP and DBP from points of maximum gradient on each OWE recorded, it may offer significant benefits over the ratio method. However, we have shown that the ratio method can be optimized for any data set to achieve either a minimum mean error (ME) of close to 0 mmHg or minimum root mean square error (RMSE) with standard deviation (SD) of <5.0 mmHg. We conclude that whilst cuff inflation may offer some advantages, these are neither significant nor substantial, leaving as the only benefit, the potential for more rapid measurement and less patient discomfort.


Sujet(s)
Mesure de la pression artérielle , Pression sanguine , Oscillométrie , Humains , Mâle , Mesure de la pression artérielle/méthodes , Mesure de la pression artérielle/instrumentation , Adulte d'âge moyen , Femelle , Oscillométrie/méthodes , Sujet âgé , Pression sanguine/physiologie
7.
BMC Pediatr ; 24(1): 296, 2024 May 03.
Article de Anglais | MEDLINE | ID: mdl-38702638

RÉSUMÉ

BACKGROUND: Cough variant asthma (CVA) is one of the most common causes of chronic cough in children worldwide. The diagnosis of CVA in children remains challenging. This study aimed to assess the diagnostic utility of impulse oscillometry (IOS) pulmonary function in children with CVA. METHODS: This study included children aged 4 to 12 years diagnosed with CVA who underwent IOS pulmonary function and bronchodilation (BD) tests. A control group of healthy children was matched. Pre- and post-BD IOS parameters were recorded and presented as mean ± standard deviation or median. Receiver operating characteristic (ROC) curves were plotted, and the area under the curve (AUC) was calculated to evaluate the discriminatory potential of the IOS parameters for diagnosing CVA. RESULTS: A total of 180 patients with CVA and 65 control subjects were included. The baseline IOS parameters in the CVA group, except X5%pred, were significantly greater compared to the control group. After inhalation of salbutamol sulfate, all IOS parameters improved significantly in the CVA group. However, Z5%pred, R5%pred, and R20%pred remained greater in the CVA group compared to the control group. The improvement rates of IOS parameters in the CVA group significantly surpassed those in the control group. The ROC curve results for pre-BD IOS parameters and the improvement rate during the BD test showed that the combinations of pre-Z5%pred+△Z5% and pre-R5%pred+△R5% achieved the highest AUC value of 0.920 and 0.898, respectively. The AUC values of these combined parameters surpassed those of individual ones. CONCLUSIONS: This study highlights that children with CVA exhibit greater IOS parameters compared to healthy children. The changes in IOS parameters during the BD test provided valuable diagnostic information for CVA, and the combination of various parameters can help pediatricians accurately identify CVA in children.


Sujet(s)
Asthme , Toux , Oscillométrie , Humains , Toux/étiologie , Toux/diagnostic , Enfant , Asthme/diagnostic , Asthme/physiopathologie , Mâle , Femelle , Oscillométrie/méthodes , Enfant d'âge préscolaire , Études cas-témoins , Courbe ROC , Salbutamol , Tests de la fonction respiratoire/méthodes , Bronchodilatateurs ,
8.
J Hypertens ; 42(6): 1075-1085, 2024 Jun 01.
Article de Anglais | MEDLINE | ID: mdl-38690906

RÉSUMÉ

Most non-invasive blood pressure (BP) measurements are carried out using instruments which implement either the Ratio or the Maximum Gradient oscillometric method, mostly during cuff deflation, but more rarely during cuff inflation. Yet, there is little published literature on the relative advantages and accuracy of these two methods. In this study of 40 lightly sedated individuals aged 64.1 ± 9.6 years, we evaluate and compare the performance of the oscillometric ratio (K) and gradient (Grad) methods for the non-invasive estimation of mean pressure, SBP and DBP with reference to invasive intra-arterial values. There was no significant difference between intra-arterial estimates of mean pressure made via Korotkoff sounds (MP-OWE) or the gradient method (MP-Grad). However, 17.7% of MP-OWE and 15% of MP-Grad were in error by more than 10 mmHg. SBP-K and SBP-Grad underestimated SBP by 14 and 18 mmHg, whilst accurately estimating DBP with mean errors of 0.4 ±â€Š5.0 and 1.7 ±â€Š6.1 mmHg, respectively. Relative to the reference standard SBP-K, SBP-Grad and DBP-Grad were estimated with a mean error of -4.5 ±â€Š6.6 and 1.4 ±â€Š5.6 mmHg, respectively, noting that using the full range of recommended ratios introduces errors of 12 and 7 mmHg in SBP and DBP, respectively. We also show that it is possible to find ratios which minimize the root mean square error (RMSE) and the mean error for any particular individual cohort. We developed linear models for estimating SBP and SBP-K from a range of demographic and non-invasive OWE variables with resulting mean errors of 0.15 ±â€Š5.6 and 0.3 ±â€Š5.7 mmHg, acceptable according to the Universal standard.


Sujet(s)
Mesure de la pression artérielle , Pression sanguine , Oscillométrie , Humains , Adulte d'âge moyen , Mesure de la pression artérielle/méthodes , Mâle , Femelle , Oscillométrie/méthodes , Sujet âgé , Pression sanguine/physiologie
9.
PLoS One ; 19(5): e0302793, 2024.
Article de Anglais | MEDLINE | ID: mdl-38739601

RÉSUMÉ

BACKGROUND: In cardiology, cardiac output (CO) is an important parameter for assessing cardiac function. While invasive thermodilution procedures are the gold standard for CO assessment, transthoracic Doppler echocardiography (TTE) has become the established method for routine CO assessment in daily clinical practice. However, a demand persists for non-invasive approaches, including oscillometric pulse wave analysis (PWA), to enhance the accuracy of CO estimation, reduce complications associated with invasive procedures, and facilitate its application in non-intensive care settings. Here, we aimed to compare the TTE and oscillometric PWA algorithm Antares for a non-invasive estimation of CO. METHODS: Non-invasive CO data obtained by two-dimensional TTE were compared with those from an oscillometric blood pressure device (custo med GmbH, Ottobrunn, Germany) using the integrated algorithm Antares (Redwave Medical GmbH, Jena, Germany). In total, 59 patients undergoing elective cardiac catheterization for clinical reasons (71±10 years old, 76% males) were included. Agreement between both CO measures were assessed by Bland-Altman analysis, Student's t-test, and Pearson correlations. RESULTS: The mean difference in CO was 0.04 ± 1.03 l/min (95% confidence interval for the mean difference: -0.23 to 0.30 l/min) for the overall group, with lower and upper limits of agreement at -1.98 and 2.05 l/min, respectively. There was no statistically significant difference in means between both CO measures (P = 0.785). Statistically significant correlations between TTE and Antares CO were observed in the entire cohort (r = 0.705, P<0.001) as well as in female (r = 0.802, P<0.001) and male patients (r = 0.669, P<0.001). CONCLUSIONS: The oscillometric PWA algorithm Antares and established TTE for a non-invasive estimation of CO are highly correlated in male and female patients, with no statistically significant difference between both approaches. Future validation studies of the Antares CO are necessary before a clinical application can be considered.


Sujet(s)
Algorithmes , Débit cardiaque , Échocardiographie-doppler , Analyse de l'onde de pouls , Humains , Mâle , Femelle , Débit cardiaque/physiologie , Sujet âgé , Analyse de l'onde de pouls/méthodes , Échocardiographie-doppler/méthodes , Adulte d'âge moyen , Sujet âgé de 80 ans ou plus , Oscillométrie/méthodes
10.
BMC Oral Health ; 24(1): 619, 2024 May 28.
Article de Anglais | MEDLINE | ID: mdl-38807138

RÉSUMÉ

PURPOSE: The aim of this in vitro study was to evaluate the changes the rheological properties of some soft lining materials, to compare the rheological properties and viscoelastic behaviour at different temperatures. MATERIALS AND METHODS: Five soft lining materials (acrylic and silicone based) were used. the storage modulus (G'), loss modulus (G"), tan delta (tan δ) and complex viscosity (η') were chosen and for each material, measurements were repeated at 23, 33 and 37  °C, using an oscillating rheometer. All data were statistically analyzed using the Mann Whitney U test, Kruskal Wallis test and Conover's Multiple Comparison test at the significance level of 0.05. RESULTS: Soft lining materials had different viscoelastic properties and most of the materials showed different rheological behavior at 23, 33 and 37  °C. At the end of the test (t¹5), at all the temperatures, Sofreliner Tough M had the highest storage modulus values while Visco Gel had the highest loss Tan delta values. CONCLUSIONS: There were significant changes in the rheological parameters of all the materials. Also temperature affected the initial rheological properties, and polymerization reaction of all the materials, depending on temperature increase. CLINICAL IMPLICATIONS: Temperature affected the initial rheological properties, and polymerization reaction of soft denture liner materials, and clinical inferences should be drawn from such studies conducted. It can be recommended to utilize viscoelastic acrylic-based temporary soft lining materials with lower storage modulus, higher tan delta value, and high viscosity in situations where pain complaint persists and tissue stress is extremely significant, provided that they are replaced often.


Sujet(s)
Résines acryliques , Test de matériaux , Rhéologie , Température , Viscosité , Résines acryliques/composition chimique , Élasticité , Vernis protecteurs d'appareil de prothèse dentaire , Module d'élasticité , Isolation de cavité dentaire , Silicone/composition chimique , Polymérisation , Humains , Oscillométrie
11.
Rev Paul Pediatr ; 42: e2023162, 2024.
Article de Anglais | MEDLINE | ID: mdl-38808869

RÉSUMÉ

OBJECTIVE: To investigate the effect of bronchodilator on the respiratory mechanics and pulmonary function of children and adolescents with cystic fibrosis. METHODS: Cross-sectional study on clinically stable children and adolescents with cystic fibrosis aged from six to 15 years. Participants underwent impulse oscillometry and spirometry evaluations before and 15 minutes after bronchodilator inhalation. The Kolmogorov-Smirnov test was applied to verify the sample distribution, and the Student's t-test and Wilcoxon test were used to compare the data before and after bronchodilator inhalation. RESULTS: The study included 54 individuals with a mean age of 9.7±2.8 years. The analysis showed a statistically significant improvement in impulse oscillometry and spirometry parameters after bronchodilator inhalation. However, according to the American Thoracic Society (ATS) and European Respiratory Society (ERS) recommendations (2020 and 2021), this improvement was not sufficient to classify it as a bronchodilator response. CONCLUSIONS: The use of bronchodilator medication improved respiratory mechanics and pulmonary function parameters of children and adolescents with cystic fibrosis; however, most patients did not show bronchodilator response according to ATS/ERS recommendations.


Sujet(s)
Bronchodilatateurs , Mucoviscidose , Oscillométrie , Spirométrie , Humains , Mucoviscidose/physiopathologie , Mucoviscidose/traitement médicamenteux , Enfant , Adolescent , Études transversales , Spirométrie/méthodes , Femelle , Mâle , Oscillométrie/méthodes , Bronchodilatateurs/usage thérapeutique , Bronchodilatateurs/administration et posologie , Mécanique respiratoire/effets des médicaments et des substances chimiques , Mécanique respiratoire/physiologie , Tests de la fonction respiratoire/méthodes
12.
J Clin Hypertens (Greenwich) ; 26(6): 703-707, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38650108

RÉSUMÉ

The aim of this study was to evaluate the accuracy of the single upper-arm cuff oscillometric blood pressure (BP) monitor RBP-9801 developed for office and home BP measurement in the general population according to the Association for the Advancement of Medical Instrumentation/European Society of Hypertension/International Organization for Standardization (AAMI/ESH/ISO) Universal Standard (ISO 81060-2:2018). Subjects were recruited to fulfil the age, gender, BP and cuff distribution criteria of the AAMI/ESH/ISO Universal Standard in general population using the same arm sequential BP measurement method. A total of 105 subjects were recruited and 85 were analyzed. For validation criterion 1, the mean ± SD of the differences between the test device and reference BP readings was 2.3 ± 6.4/3.1 ± 5.8 mmHg (systolic/diastolic). For criterion 2, the SD of the mean BP differences between the test device and reference BP per subject was 5.24/5.03 mmHg (systolic/diastolic). The conclusion is that the RBP-9801 oscillometric device for office and home BP measurement fulfilled all the requirements of the AAMI/ESH/ISO Universal Standard (ISO 81060-2:2018) in the general population and can be recommended for clinic and self-use at home.


Sujet(s)
Mesure de la pression artérielle , Hypertension artérielle , Oscillométrie , Humains , Mâle , Femelle , Adulte d'âge moyen , Oscillométrie/instrumentation , Oscillométrie/normes , Hypertension artérielle/diagnostic , Hypertension artérielle/physiopathologie , Mesure de la pression artérielle/instrumentation , Mesure de la pression artérielle/méthodes , Mesure de la pression artérielle/normes , Adulte , Moniteurs de pression artérielle/normes , Pression sanguine/physiologie , Sujet âgé , Surveillance ambulatoire de la pression artérielle/instrumentation , Surveillance ambulatoire de la pression artérielle/normes , Surveillance ambulatoire de la pression artérielle/méthodes , Reproductibilité des résultats
13.
Physiol Meas ; 45(5)2024 May 30.
Article de Anglais | MEDLINE | ID: mdl-38599216

RÉSUMÉ

Objective. Diagnosing chronic obstructive pulmonary disease (COPD) using impulse oscillometry (IOS) is challenging due to the high level of clinical expertise it demands from doctors, which limits the clinical application of IOS in screening. The primary aim of this study is to develop a COPD diagnostic model based on machine learning algorithms using IOS test results.Approach. Feature selection was conducted to identify the optimal subset of features from the original feature set, which significantly enhanced the classifier's performance. Additionally, secondary features area of reactance (AX) were derived from the original features based on clinical theory, further enhancing the performance of the classifier. The performance of the model was analyzed and validated using various classifiers and hyperparameter settings to identify the optimal classifier. We collected 528 clinical data examples from the China-Japan Friendship Hospital for training and validating the model.Main results. The proposed model achieved reasonably accurate diagnostic results in the clinical data (accuracy = 0.920, specificity = 0.941, precision = 0.875, recall = 0.875).Significance. The results of this study demonstrate that the proposed classifier model, feature selection method, and derived secondary feature AX provide significant auxiliary support in reducing the requirement for clinical experience in COPD diagnosis using IOS.


Sujet(s)
Apprentissage machine , Oscillométrie , Broncho-pneumopathie chronique obstructive , Broncho-pneumopathie chronique obstructive/diagnostic , Broncho-pneumopathie chronique obstructive/physiopathologie , Humains , Oscillométrie/méthodes , Mâle , Femelle , Adulte d'âge moyen , Algorithmes , Sujet âgé
14.
Physiol Meas ; 45(5)2024 May 24.
Article de Anglais | MEDLINE | ID: mdl-38688296

RÉSUMÉ

Background.Non-invasive continuous blood pressure (BP) monitoring is of longstanding interest in various cardiovascular scenarios. In this context, pulse arrival time (PAT), i.e., a surrogate parameter for systolic BP (change), became very popular recently, especially in the context of cuffless BP measurement and dedicated lifestyle interventions. Nevertheless, there is also understandable doubt on its reliability in uncontrolled and mobile settings.Objective.The aim of this work is therefore the investigation whether PAT follows oscillometric systolic BP readings during moderate interventions by physical or mental activity using a medical grade handheld device for non-invasive PAT assessment.Approach.A study was conducted featuring an experimental group performing a physical and a mental task, and a control group. Oscillometric BP and PAT were assessed at baseline and after each intervention. Interventions were selected randomly but then performed sequentially in a counterbalanced order. Multivariate analyses of variance were used to test within-subject and between-subject effects for the dependent variables, followed by univariate analyses for post-hoc testing. Furthermore, correlation analysis was performed to assess the association of intervention effects between BP and PAT.Mainresults.The study included 51 subjects (31 females). Multivariate analysis of variances showed that effects in BP, heart rate, PAT and pulse wave parameters were consistent and significantly different between experimental and control groups. After physical activity, heart rate and systolic BP increased significantly whereas PAT decreased significantly. Mental activity leads to a decrease in systolic BP at stable heart rate. Pulse wave parameters follow accordingly by an increase of PAT and mainly unchanged pulse wave analysis features due to constant heart rate. Finally, also the control group behaviour was accurately registered by the PAT method compared to oscillometric cuff. Correlation analyses revealed significant negative associations between changes of systolic BP and changes of PAT from baseline to the physical task (-0.33 [-0.63, 0.01],p< 0.048), and from physical to mental task (-0.51 [-0.77, -0.14],p= 0.001), but not for baseline to mental task (-0.12 [-0,43,0,20],p= 0.50) in the experimental group.Significance.PAT and the used digital, handheld device proved to register changes in BP and heart rate reliably compared to oscillometric measurements during intervention. Therefore, it might add benefit to future mobile health solutions to support BP management by tracking relative, not absolute, BP changes during non-pharmacological interventions.


Sujet(s)
Mesure de la pression artérielle , Pression sanguine , Oscillométrie , Humains , Femelle , Mâle , Pression sanguine/physiologie , Mesure de la pression artérielle/méthodes , Adulte , Systole/physiologie , Adulte d'âge moyen , Rythme cardiaque/physiologie , Exercice physique , Facteurs temps
15.
Blood Press ; 33(1): 2338208, 2024 Dec.
Article de Anglais | MEDLINE | ID: mdl-38591393

RÉSUMÉ

OBJECTIVE: Some brachial cuffs for oscillometric blood pressure (BP) measurement are claimed to cover a wide range of upper-arm circumferences; however, their validation is rarely conducted. Our aim was to compare oscillometric BP measurements obtained with a universal cuff with those obtained with an appropriately sized cuff. METHODS: We utilised the Microlife B6 Connect monitor, conducting oscillometric BP measurements in a random sequence with both a universal cuff (recommended for arm circumferences from 22 to 42 cm) and an appropriately sized cuff (medium for circumference 22-32 cm and large for 32-42 cm). We included 91 individuals with an arm circumference of 22-32 cm and 64 individuals with an arm circumference of 32-42 cm. RESULTS: For arm circumferences > 32 cm, systolic and diastolic BP measured with the universal cuff was higher than that measured with the large cuff (systolic 6.4 mmHg, 95% confidence interval [CI]). 3.9-8.8, diastolic 2.4 mmHg, 95%CI, 1.2-3.7, p < 0.001 for both). Overestimation of BP with the universal cuff was statistically significant after correcting for the sequence of measurements. No statistical difference was found between the universal cuff and medium cuff for circumferences in the 22-32 cm range. The bladder size in the universal cuff matched the dimensions of the medium-sized cuff; however, the cuff was larger. CONCLUSION: Overestimation of BP measured with a universal cuff in persons with large arm circumferences is clinically important. It poses the risk of unnecessary initiation or intensification of antihypertensive medication in persons using the universal cuff.


What is the context?Clinical guidelines recommend individualisation of the size of the cuff used for blood pressure measurement according to the circumference of the upper arm.Many blood pressure monitors are sold with a single "universal" cuff claimed to cover a wide range of upper arm sizes.We compared blood pressure obtained with the Microlife B6 Connect monitor and a "universal" cuff with the results obtained with individual sized cuffs (medium size for arm circumference between 22 and 32 cm and large size for arm circumference between 32 and 42 cm).What is new?In persons with large upper arm circumference is the systolic blood pressure 6.4 mmHg higher and the diastolic blood pressure 2.4 mmHg higher with the universal cuff than with the individual-sized large cuff.What is the impact?The universal cuff overestimates blood pressure in persons with large arm circumference.


Sujet(s)
Mesure de la pression artérielle , Membre supérieur , Humains , Pression sanguine/physiologie , Mesure de la pression artérielle/méthodes , Oscillométrie/méthodes , Diastole , Moniteurs de pression artérielle
16.
Article de Anglais | MEDLINE | ID: mdl-38464561

RÉSUMÉ

Purpose: Chronic obstructive pulmonary disease (COPD) phenotypes may introduce different characteristics that need to be known to improve treatment. Respiratory oscillometry provides a detailed analysis and may offer insight into the pathophysiology of COPD. In this paper, we used this method to evaluate the differences in respiratory mechanics of COPD phenotypes. Patients and Methods: This study investigated a sample of 83 volunteers, being divided into control group (CG = 20), emphysema (n = 23), CB (n = 20) and asthma-COPD overlap syndrome (ACOS, n = 20). These analyses were performed before and after bronchodilator (BD) use. Functional capacity was evaluated using the Glittre­ADL test, handgrip strength and respiratory pressures. Results: Initially it was observed that oscillometry provided a detailed description of the COPD phenotypes, which was consistent with the involved pathophysiology. A correlation between oscillometry and functional capacity was observed (r=-0.541; p = 0.0001), particularly in the emphysema phenotype (r = -0.496, p = 0.031). BD response was different among the studied phenotypes. This resulted in an accurate discrimination of ACOS from CB [area under the receiver operating curve (AUC) = 0.84] and emphysema (AUC = 0.82). Conclusion: These results offer evidence that oscillatory indices may enhance the comprehension and identification of COPD phenotypes, thereby potentially improving the support provided to these patients.


Sujet(s)
Asthme , Emphysème , Broncho-pneumopathie chronique obstructive , Emphysème pulmonaire , Humains , Broncho-pneumopathie chronique obstructive/diagnostic , Broncho-pneumopathie chronique obstructive/traitement médicamenteux , Poumon , Oscillométrie/méthodes , Force de la main , Volume expiratoire maximal par seconde , Bronchodilatateurs/usage thérapeutique , Phénotype , Performance fonctionnelle physique
17.
Rev. patol. respir ; 27(1): 27-30, ene.-mar2024. tab, graf
Article de Espagnol | IBECS | ID: ibc-231681

RÉSUMÉ

La oscilometría es una herramienta que, poco a poco, se está abriendo paso en las consultas de neumología y alergología. Se trata de una técnica sencilla de realizar para el paciente, que, además, aporta información adicional a las pruebas de función respiratoria clásicas. No solamente nos indica la alteración que existe en la vía aérea, sino que localiza a qué altura se produce (central o periférica). El objetivo es acercar esta técnica al personal sanitario y hacer más sencilla su interpretación. (AU)


Oscillometry is a tool that is gradually making its way into the daily routine of pneumology and allergology. It is a simple technique for the patient, which also provides additional information to the classic respiratory function tests. It not only indicates if there is an alteration in the airway, but also locates where it occurs (central or peripheral). The aim is to bring this technique closer to healthcare professionals and facilitate its interpretation. (AU)


Sujet(s)
Humains , Physiologie , Oscillométrie , Pneumologie , Allergie et immunologie , Poumon
18.
Respir Res ; 25(1): 149, 2024 Mar 30.
Article de Anglais | MEDLINE | ID: mdl-38555433

RÉSUMÉ

BACKGROUND: The clinical significance of the impulse oscillometry-defined small airway bronchodilator response (IOS-BDR) is not well-known. Accordingly, this study investigated the clinical characteristics of IOS-BDR and explored the association between lung function decline, acute respiratory exacerbations, and IOS-BDR. METHODS: Participants were recruited from an Early Chronic Obstructive Pulmonary Disease (ECOPD) cohort subset and were followed up for two years with visits at baseline, 12 months, and 24 months. Chronic obstructive pulmonary disease (COPD) was defined as a post-bronchodilator forced expiratory volume in 1 s (FEV1)/forced vital capacity (FVC) ratio < 0.70. IOS-BDR was defined as meeting any one of the following criteria: an absolute change in respiratory system resistance at 5 Hz ≤ - 0.137 kPa/L/s, an absolute change in respiratory system reactance at 5 Hz ≥ 0.055 kPa/L/s, or an absolute change in reactance area ≤ - 0.390 kPa/L. The association between IOS-BDR and a decline in lung function was explored with linear mixed-effects model. The association between IOS-BDR and the risk of acute respiratory exacerbations at the two-year follow-up was analyzed with the logistic regression model. RESULTS: This study involved 466 participants (92 participants with IOS-BDR and 374 participants without IOS-BDR). Participants with IOS-BDR had higher COPD assessment test and modified Medical Research Council dyspnea scale scores, more severe emphysema, air trapping, and rapid decline in FVC than those without IOS-BDR over 2-year follow-up. IOS-BDR was not associated with the risk of acute respiratory exacerbations at the 2-year follow-up. CONCLUSIONS: The participants with IOS-BDR had more respiratory symptoms, radiographic structural changes, and had an increase in decline in lung function than those without IOS-BDR. TRIAL REGISTRATION: Chinese Clinical Trial Registry, ChiCTR1900024643. Registered on 19 July, 2019.


Sujet(s)
Asthme , Broncho-pneumopathie chronique obstructive , Humains , Asthme/diagnostic , Bronchodilatateurs/usage thérapeutique , Volume expiratoire maximal par seconde , Oscillométrie , Broncho-pneumopathie chronique obstructive/diagnostic , Broncho-pneumopathie chronique obstructive/traitement médicamenteux , Tests de la fonction respiratoire , Spirométrie
19.
Blood Press Monit ; 29(4): 167-172, 2024 Aug 01.
Article de Anglais | MEDLINE | ID: mdl-38465772

RÉSUMÉ

OBJECTIVE: Understanding of how oscillometric waveforms (OMW) vary between pregnant and nonpregnant individuals remains low. An exploratory analysis was completed to assess for quantitative and qualitative changes in OMW and oscillometric envelope features in pregnancy. DESIGN AND METHODS: Eighteen pregnant individuals (over 20 weeks gestational age) and healthy, nonpregnant (HNP) women were recruited. Six HNP were matched to six healthy pregnant (HP) women, and six pregnant women with a hypertensive disorder of pregnancy (HDP) by age, arm circumference, and cuff size. Blood pressure measurements were completed per the International Organization for Standardization (ISO) protocol using a custom-built oscillometric device as the test device and two-observer mercury auscultation as the reference measurement. Auscultatory blood pressure and blood pressure derived from slope-based and fixed ratio algorithms were determined. OMW and envelope features were compared among groups. RESULTS: In HNP, HP, and HDP groups respectively: mean auscultatory blood pressure (systolic mean ± SD/diastolic mean ± SD) was 103.4 ±â€…12.2/67.1 ±â€…7.9; 109.5 ±â€…3.1/58.1 ±â€…6.4; 135.6 ±â€…18.9/85.1 ±â€…14.2 mmHg. HDP had significantly higher auscultatory systolic and diastolic blood pressure than the HP group ( P  = 0.001). The pregnant groups had a lower average pulse width (mean ± SD: HNP = 0.8 ±â€…0 s, HP = 0.6 ±â€…0.1 s, HDP = 0.6 ±â€…0.1 s; HP vs. HNP mean difference [adjusted P value]: 0.2 [ P  = 0.004], HDP vs. HNP 0.1 [ P  = 0.018]) compared with the HNP group. The HDP group had a larger area under the OMW envelope than the HNP group (mean ± SD: HNP = 22.6 ±â€…3.4; HDP = 28.5 ±â€…4.2; HDP vs. HNP mean difference [adjusted P value]: 5.9 P  = 0.05). CONCLUSION: In this exploratory work, differences in the OMW morphology and parameters were found in pregnancy and in hypertensive disorders of pregnancy compared with healthy controls. Even small differences may have important implications in algorithm development; further work comparing OMW envelopes in pregnancy is needed to optimize the algorithms used to determine blood pressure in pregnancy.


Sujet(s)
Hypertension artérielle gravidique , Oscillométrie , Humains , Femelle , Grossesse , Adulte , Hypertension artérielle gravidique/physiopathologie , Oscillométrie/instrumentation , Pression sanguine , Mesure de la pression artérielle/méthodes , Mesure de la pression artérielle/instrumentation
20.
Clinics (Sao Paulo) ; 79: 100313, 2024.
Article de Anglais | MEDLINE | ID: mdl-38490138

RÉSUMÉ

INTRODUCTION: Studies suggest peripheral airway abnormalities in Pulmonary Arterial Hypertension (PAH). Impulse Oscillometry (IOS) is a noninvasive and sensitive technique for assessing the small airways. It evaluates the impedance of the respiratory system ‒ Resistance (R) and reactance (X) ‒ to a pulse of sound waves sent to the lungs, in a range of frequencies (5‒20 Hz). METHOD: Resistance variables: R5, R20, R5-R20 and reactance variables: AX (reactance area) and Fres (resonance frequency). The aim is to evaluate R and X in patients with idiopathic PAH (IPAH) and to investigate whether there is a correlation between IOS and spirometry. RESULTS: Thirteen IPAH patients and 11 healthy subjects matched for sex and age underwent IOS and spirometry. IPAH patients had lower FVC and FEV1 values (p < 0.001), VEF1/CVF (p = 0.049) and FEF 25-75 (p = 0.006) than healthy patients. At IOS, IPAH patients showed lower tidal volumes and higher AX (p < 0.05) compared to healthy individuals, and 53.8 of patients had R5-R20 values ≥ 0.07 kPa/L/s. Correlation analysis: X5, AX, R5-R20 and Fres showed moderate correlation with FVC (p = 0.036 r = 0.585, p = 0.001 r = -0.687, p = 0.005 r = -0.726 and p = 0.027 r = -0.610); Fres (p = 0.012 r = -0.669) and AX (p = 0.006 r = -0.711) correlated with FEV1; [R5 and R20, (R5-R20)] also correlated with FEV1 (p < 0.001 r = -0.573, p = 0.020 r = -0.634 and p = 0.010 r = -0.683, respectively) in the IPAH group. There were also moderate correlations of FEF 25-75 % with Z5 (p = 0.041), R5 (p = 0.018), Fres (p = 0.043) and AX (p = 0.023). DISCUSSION: Patients showed changes suggestive of increased resistance and reactance in the IOS compared to healthy individuals, and the IOS findings showed a good correlation with spirometry variables.


Sujet(s)
Hypertension artérielle pulmonaire , Humains , Oscillométrie/méthodes , Volume expiratoire maximal par seconde , Tests de la fonction respiratoire/méthodes , Poumon , Spirométrie