Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 3.426
Filtrer
1.
BMC Oral Health ; 24(1): 893, 2024 Aug 04.
Article de Anglais | MEDLINE | ID: mdl-39098928

RÉSUMÉ

BACKGROUND: Polymethylmethacrylate (PMMA) bone cement is used in orthopedics and dentistry to get primary fixation to bone but doesn't provide a mechanically and biologically stable bone interface. Therefore, there was a great demand to improve the properties of the PMMA bone cement to reduce its clinical usage limitations and enhance its success rate. Recent studies demonstrated that the addition of halloysite nanotubes (HNTs) to a polymeric-based material can improve its mechanical and thermal characteristics. OBJECTIVES: The purpose of the study is to assess the compressive strength, flexural strength, maximum temperature, and setting time of traditional PMMA bone cements that have been manually blended with 7 wt% HNT fillers. METHODS: PMMA powder and monomer liquid were combined to create the control group, the reinforced group was made by mixing the PMMA powder with 7 wt% HNT fillers before liquid mixing. Chemical characterization of the HNT fillers was employed by X-ray fluorescence (XRF). The morphological examination of the cements was done using a scanning electron microscope (SEM). Analytical measurements were made for the compressive strength, flexural strength, maximum temperature, and setting time. Utilizing independent sample t-tests, the data was statistically assessed to compare mean values (p < 0.05). RESULTS: The findings demonstrated that the novel reinforced PMMA-based bone cement with 7 wt% HNT fillers showed higher mean compressive strength values (93 MPa) and higher flexural strength (72 MPa). and lower maximum temperature values (34.8 °C) than the conventional PMMA bone cement control group, which was (76 MPa), (51 MPa), and (40 °C), respectively (P < 0.05). While there was no significant difference in the setting time between the control and the modified groups. CONCLUSION: The novel PMMA-based bone cement with the addition of 7 wt% HNTs can effectively be used in orthopedic and dental applications, as they have the potential to enhance the compressive and flexural strength and reduce the maximum temperatures.


Sujet(s)
Ciments osseux , Argile , Résistance à la compression , Résistance à la flexion , Test de matériaux , Microscopie électronique à balayage , Nanotubes , Poly(méthacrylate de méthyle) , Poly(méthacrylate de méthyle)/composition chimique , Nanotubes/composition chimique , Argile/composition chimique , Ciments osseux/composition chimique , Silicates d'aluminium/composition chimique , Spectrométrie d'émission X , Température , Propriétés de surface
2.
Methods Mol Biol ; 2835: 307-315, 2024.
Article de Anglais | MEDLINE | ID: mdl-39105926

RÉSUMÉ

Cell therapy and engineered tissue creation based on the use of human stem cells involves cell isolation, expansion, and cell growth and differentiation on the scaffolds. Microbial infections dramatically can affect stem cell survival and increase the risk of implant failure. To prevent these events, it is necessary to develop new materials with antibacterial properties for coating scaffold surfaces as well as medical devices, and all other surfaces at high risk of contamination. This chapter describes strategies for obtaining antibacterial blends for coating inert surfaces (polymethylmethacrylate, polycarbonate, Carbon Fiber Reinforced Polymer (CFRP)). In particular, the procedures for preparing antibacterial blends by mixing polymer resins with two types of antibacterial additives and depositing these blends on inert surfaces are described.


Sujet(s)
Cellules souches , Ingénierie tissulaire , Humains , Ingénierie tissulaire/méthodes , Cellules souches/cytologie , Propriétés de surface , Structures d'échafaudage tissulaires/composition chimique , Antibactériens/pharmacologie , Ciment carboxylate/composition chimique , Techniques de culture cellulaire/méthodes , Poly(méthacrylate de méthyle)/composition chimique , Fibre de carbone/composition chimique , Carbone/composition chimique , Anti-infectieux/pharmacologie
3.
Int J Nanomedicine ; 19: 8485-8499, 2024.
Article de Anglais | MEDLINE | ID: mdl-39185343

RÉSUMÉ

Introduction: With the development of technology, personal heat management has become a focus of attention. Phase change fabrics, as intelligent materials, are expected to be widely used in multiple fields, bringing comfortable, intelligent and convenient living experience. Methods: In this study, miniature phase change microcapsules (MPCM) with n-octadecane as core and poly(methyl methacrylate) as shell were successfully prepared. Using the in-situ reduction property of polydopamine, gold nanoparticles were deposited on the surface of the microcapsules, which retained the heat storage function and imparted photothermal and antibacterial properties. The MPCM with photothermal conversion function was modified on the surface of silk fabric using aqueous polyurethane after verified by comprehensive material characterisation techniques. Results: Under the near infrared light of 808 nm wavelength and 0.134 W/cm² irradiation intensity, the MPCM@PDA@Au modified silk fabrics showed excellent photothermal conversion performance, which could be increased from 25°C to 60°C in 50s. After the light source was cut off, the fabrics showed good heat release ability, with melting enthalpy and crystallisation enthalpy reaching 41.58 J/g and 43.3 J/g, respectively, which were not changed after repeated cycles. After the light source is cut off, the fabric has good heat release ability, and the enthalpy of melting and crystallisation reaches 41.58 J/g and 43.3 J/g, respectively, and the photothermal efficiency remains unchanged after many cycles of use, which proves that it has excellent durability and stability. The antimicrobial test shows that the fabric has significant antibacterial effect on Escherichia coli (E. coli) and Staphylococcus aureus (S. aureus). Discussion: MPCM@PDA@Au silk fabrics bring new possibilities for the future of personal thermal management and antimicrobial protection in the field of medical health, outdoor sports and other areas of broad application prospects, heralding the birth of a series of innovative applications and solutions.


Sujet(s)
Antibactériens , Capsules , Or , Nanoparticules métalliques , Soie , Textiles , Or/composition chimique , Nanoparticules métalliques/composition chimique , Capsules/composition chimique , Soie/composition chimique , Antibactériens/composition chimique , Antibactériens/pharmacologie , Indoles/composition chimique , Indoles/pharmacologie , Escherichia coli/effets des médicaments et des substances chimiques , Staphylococcus aureus/effets des médicaments et des substances chimiques , Polymères/composition chimique , Humains , Transition de phase , Poly(méthacrylate de méthyle)/composition chimique , Rayons infrarouges
4.
Water Res ; 263: 122177, 2024 Oct 01.
Article de Anglais | MEDLINE | ID: mdl-39111211

RÉSUMÉ

For the resource recovery of biomass waste, it is a challenge to simultaneously remove micro-/nano-plastics pollution but preserve organic resources. Wet oxidation is a promising technology for valorization of organic wastes through thermal hydrolysis and oxidation. This might in turn result in the degradation of microplastics in the presence of oxygen and high temperatures. Based on this hypothesis, this study quantified both microplastics and nanoplastics in an industrial-scale wet oxidation reactor from a full-size coverage perspective. Wet oxidation significantly reduced the size and mass of individual microplastics, and decreased total mass concentration of microplastics and nanoplastics by 94.8 % to 98.6 %. This technology also reduced the micro- and nanoplastic shapes and polymer types, resulting in a complete removal of fibers, clusters, polypropylene (PP) and poly(methyl methacrylate) (PMMA). The present study confirms that wet oxidation technology is effective in removing microplastics and nanoplastics while recovering organic waste.


Sujet(s)
Microplastiques , Oxydoréduction , Polluants chimiques de l'eau/composition chimique , Polypropylènes/composition chimique , Matières plastiques/composition chimique , Poly(méthacrylate de méthyle)/composition chimique
5.
J Mater Sci Mater Med ; 35(1): 50, 2024 Aug 13.
Article de Anglais | MEDLINE | ID: mdl-39136804

RÉSUMÉ

The human head can sometimes experience impact loads that result in skull fractures or other injuries, leading to the need for a craniectomy. Cranioplasty is a procedure that involves replacing the removed portion with either autologous bone or alloplastic material. While titanium has traditionally been the preferred material for cranial implants due to its excellent properties and biocompatibility, its limitations have prompted the search for alternative materials. This research aimed to explore alternative materials to titanium for cranial implants in order to address the limitations of titanium implants and improve the performance of the cranioplasty process. A 3D model of a defective skull was reconstructed with a cranial implant, and the implant was simulated using various stiff and soft materials (such as alumina, zirconia, hydroxyapatite, zirconia-reinforced PMMA, and PMMA) as alternatives to titanium under 2000N impact forces. Alumina and zirconia implants were found to reduce stresses and strains on the skull and brain compared to titanium implants. However, PMMA implants showed potential for causing skull damage under current loading conditions. Additionally, PMMA and hydroxyapatite implants were prone to fracture. Despite these findings, none of the implants exceeded the limits for tensile and compressive stresses and strains on the brain. Zirconia-reinforced PMMA implants were also shown to reduce stresses and strains on the skull and brain compared to PMMA implants. Alumina and zirconia show promise as alternatives to titanium for the production of cranial implants. The use of alternative implant materials to titanium has the potential to enhance the success of cranial reconstruction by overcoming the limitations associated with titanium implants.


Sujet(s)
Matériaux biocompatibles , Analyse des éléments finis , Test de matériaux , , Crâne , Contrainte mécanique , Titane , Zirconium , Humains , Crâne/chirurgie , Titane/composition chimique , Matériaux biocompatibles/composition chimique , Zirconium/composition chimique , /méthodes , Prothèses et implants , Durapatite/composition chimique , Poly(méthacrylate de méthyle)/composition chimique , Oxyde d'aluminium/composition chimique , Résistance à la traction , Fractures du crâne/chirurgie , Résistance à la compression
6.
PLoS One ; 19(8): e0305315, 2024.
Article de Anglais | MEDLINE | ID: mdl-39159167

RÉSUMÉ

The morphological dynamics of microbial cell proliferation on an antimicrobial surface at an early growth stage was studied with Escherichia coli on the surface of a gel supplied with AgNbO3 antimicrobial particles. We demonstrated an inhibitory surface concentration, analogous to minimum inhibitory concentration, beyond which the growth of colonies and formation of biofilm are inhibited. In contrast, at lower concentrations of particles, after a lag time the cells circumvent the antimicrobial activity of the particles and grow with a rate similar to the case in the absence of particles. The lag time depends on the surface concentration of the particles and amounts to 2 h at a concentration of ½ minimum inhibitory concentration. The applicability of these findings, in terms of estimating inhibitory surface concentration, was tested in the case of antimicrobial polymethyl methacrylate (PMMA) bone cement.


Sujet(s)
Escherichia coli , Tests de sensibilité microbienne , Escherichia coli/effets des médicaments et des substances chimiques , Escherichia coli/croissance et développement , Biofilms/effets des médicaments et des substances chimiques , Biofilms/croissance et développement , Poly(méthacrylate de méthyle)/composition chimique , Anti-infectieux/pharmacologie , Propriétés de surface , Antibactériens/pharmacologie , Niobium/pharmacologie , Niobium/composition chimique , Ciments osseux/pharmacologie
7.
J Mech Behav Biomed Mater ; 158: 106662, 2024 Oct.
Article de Anglais | MEDLINE | ID: mdl-39096682

RÉSUMÉ

Minimally invasive spine treatments have been sought after for elderly patients with comorbidities suffering from advanced degenerative disc disease. Percutaneous cement discoplasty (PCD) is one such technique where cement is injected into a degenerated disc with a vacuum phenomenon to relieve patients from pain. Adjacent vertebral fractures (AVFs) are however an inherent risk, particularly for osteoporotic patients, due to the high stiffness of the used cements. While low-modulus cements have been developed for vertebroplasty through the addition of linoleic acid, there are no such variations with a high-viscosity base cement, which is likely needed for the discoplasty application. Therefore, a low-modulus polymethyl methacrylate was developed by the addition of 12%vol. linoleic acid to a high-viscosity bone cement (hv-LA-PMMA). Initial experimental validation of the cement was performed by mechanical testing under compression over a period of 24 weeks, after storage in 37 °C phosphate buffer saline (PBS) solution. Furthermore, cement extracts were used to evaluate residual monomer release and the cytotoxicity of hv-LA-PMMA using fibroblastic cells. Relative to the base commercial cement, a significant reduction of Young's modulus and compressive strength of 36% and 42% was observed, respectively. Compression-tension fatigue tests at 5 MPa gave an average fatigue limit of 31,078 cycles. This was higher than another low-modulus cement and comparable to the fatigue properties of the disc annulus tissue. Monomer release tests showed that hv-LA-PMMA had a significantly higher release between 24 h and 7 days compared to the original bone cement, similarly to other low-modulus cements. Also, the control cement showed cytocompatibility at all time points of extract collection for 20-fold dilution, while hv-LA-PMMA only showed the same for extract collections at day 7. However, the 20-fold dilution was needed for both the control and the hv-LA-PMMA extracts to demonstrate more than 70% fibroblast viability at day 7. In conclusion, the mechanical testing showed promise in the use of linoleic acid in combination with a high-viscosity PMMA cement to achieve properties adequate to the application. Further testing and in vivo studies are however required to fully evaluate the mechanical performance and biocompatibility of hv-LA-PMMA for possible future clinical application.


Sujet(s)
Ciments osseux , Acide linoléique , Test de matériaux , Phénomènes mécaniques , Ciments osseux/composition chimique , Animaux , Acide linoléique/composition chimique , Souris , Essais Mécaniques , Poly(méthacrylate de méthyle)/composition chimique , Matériaux biocompatibles/composition chimique , Matériaux biocompatibles/pharmacologie , Viscosité , Résistance à la compression , Humains
8.
J Mech Behav Biomed Mater ; 158: 106680, 2024 Oct.
Article de Anglais | MEDLINE | ID: mdl-39153408

RÉSUMÉ

This research paper explores the advancement of physical models simulating the human skull-brain complex, focusing on applications in simulating mild Traumatic Brain Injury (mTBI). Existing models, especially head forms, lack biofidelity in accurately representing the native structures of the skull, limiting the understanding of intracranial injury parameters beyond kinematic head accelerations. This study addresses this gap by investigating the use of additive manufacturing (AM) techniques to develop biofidelic skull surrogates. Materials such as Polylactic Acid (PLA), a bone-simulant PLA variant, and Hydroxyapatite-coated Poly(methyl methacrylate) (PMMA) were used to create models tested for their flexural modulus and strength. The trabecular bone regions were simulated by adjusting infill densities (30%, 50%, 80%) and print raster directions, optimizing manufacturing parameters for biofidelic performance. Among the tested materials, PLA and its bone-simulating variant printed at 80% infill density with a side (tangential) print orientation demonstrated the closest approximation to the mechanical properties of cranial bone, yielding a mean flexural modulus of 1337.2 MPa and a mean ultimate strength of 56.9 MPa. Statistical analyses showed that infill density significantly influenced the moduli and strength of the printed simulants. Digital Image Correlation (DIC) corroborated the comparable performance of the simulants, showing similar strain and displacement behaviors to native skull bone. Notably, the performance of the manufactured cortical and trabecular regions underscored their crucial role in achieving biofidelity, with the trabecular structure providing critical dampening effects when the native bone is loaded. This study establishes PLA, particularly its bone-simulant variant, as an optimal candidate for cranial bone simulants, offering significant potential for developing more accurate biofidelic head models in mTBI research.


Sujet(s)
Crâne , Phénomènes biomécaniques , Test de matériaux , Humains , Polyesters/composition chimique , Poly(méthacrylate de méthyle)/composition chimique , Phénomènes mécaniques , Tête/anatomie et histologie
9.
BMC Oral Health ; 24(1): 1000, 2024 Aug 25.
Article de Anglais | MEDLINE | ID: mdl-39183299

RÉSUMÉ

BACKGROUND: Digitally fabricated dentures may require relining due to continual alveolar ridge resorption. However, studies evaluating the tensile bond strength (TBS) of digitally fabricated dentures bonded to denture liners are lacking. This study aimed to evaluate the TBS of autopolymerized, heat-polymerized, milled, and 3D printed denture base materials bonded to 2 acrylic-based and 2 silicone-based denture liners, both before and after thermocycling. Additionally, the impact of thermocycling on the TBS were also evaluated. METHODS: The TBS of 4 different denture base materials (Palapress (PL), Vertex Rapid Simplified (VR), Smile CAM total prosthesis (SC), and NextDent denture 3D+ (ND)) bonded to 2 acrylic-based (GC Soft-Liner (GC) and Tokuyama Rebase II (RB)) and 2 silicone-based (Ufi Gel P (UP) and Sofreliner Tough M (ST)) denture liners were tested. Specimens (n = 8) were divided into non-thermocycling and thermocycling groups. Non-thermocycling specimens were tested after 24-hours water immersion, while thermocycling specimens were underwent 5000 cycle and were immediately tested. Mode of failure was examined under a stereomicroscope. Data were analyzed using 2-way ANOVA and Tukey HSD tests (α = 0.05), and independent samples t test (α = 0.05) for TBS between non-thermocycling and thermocycling groups. RESULTS: For the non-thermocycling groups, within the same denture liner material, no significant differences were found between denture base materials, except the ND + RB group, which had significantly lower TBS. For the thermocycling groups, within the same denture liner material, the TBS in the PL group exhibited the highest and the ND group exhibited the lowest. Within the same denture base material, in both non-thermocycling and thermocycling groups, the TBS in the ST group exhibited the highest; in contrast, that in the GC group exhibited the lowest. No significant differences were observed in TBS between non-thermocycling and thermocycling groups, except for denture base materials bonded to the ST group, SC + UP, and ND + UP groups. CONCLUSIONS: Milled denture base can be relined with acrylic-based or silicone-based denture liner. However, cautions should be exercised when relining 3D printed denture base. Thermocycling did not affect TBS between acrylic-based denture liners and denture bases. In contrast, it affected the bond between silicone-based denture liner and denture base.


Sujet(s)
Bases d'appareil de prothèse dentaire , Vernis protecteurs d'appareil de prothèse dentaire , Test de matériaux , Impression tridimensionnelle , Résistance à la traction , Résines acryliques/composition chimique , Collage dentaire/méthodes , Humains , Polymérisation , Matériaux dentaires/composition chimique , Techniques in vitro , Température élevée , Analyse du stress dentaire , Poly(méthacrylate de méthyle)/composition chimique , Silicone/composition chimique , Siloxane élastomère/composition chimique
10.
Am J Dent ; 37(4): 206-209, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-39186602

RÉSUMÉ

PURPOSE: To evaluate the in vitro antibacterial effect of Softsoap and Efferdent used as solutions to disinfect Lucitone 199 poly(methyl methacrylate) (PMMA) resin used for dentures. METHODS: S. mutans and plaque bacteria were grown for 24 hours, and suspended to a concentration of 1x106 cells/ml. Bacterial suspensions (0.2 mL) were added to the decontaminated PMMA discs placed in a 48-well culture plate and incubated for 3 days at 37°C. The discs were rinsed to remove the unbound bacterial cells and then incubated for 60 minutes with 5% and 1% dilutions (triplicates) of each of the detergent solutions (0.3 ml). Discs were rinsed and then MTT reagent (0.2 ml) was added and incubated for 2 hours, then overnight with a solubilizing agent. An aliquot from each well (0.1 ml) was transferred to a 96-well flat bottom plate and absorbance was measured to OD @ 595 nm (MTT) of four samples for each data point. Normalized data was compared and statistically analyzed using a three-way ANOVA with Student-Newman-Keuls on Rank data with P< 0.05 for significance. Additionally, data were double-checked with the Holm-Sidak test. RESULTS: There was no statistically significant difference between testing media for C. albicans and mixed plaque (P= 0.078) or testing duration in time at 24 hours and 21 days (P= 0.07). Statistically significant differences were found between all treatment solutions group combinations (P< 0.001) except for 30% Softsoap versus Efferdent (P= 0.056). CLINICAL SIGNIFICANCE: There was no statistically significant difference between testing media for C. albicans and mixed plaque (P= 0.078) or testing duration at 24 hours and 21 days (P= 0.07). Statistically significant differences were noted between all treatment solutions group combinations (P< 0.001), However, there was no difference between 30% Softsoap and Efferdent (P= 0.056).


Sujet(s)
Antibactériens , Poly(méthacrylate de méthyle) , Poly(méthacrylate de méthyle)/composition chimique , Antibactériens/pharmacologie , Streptococcus mutans/effets des médicaments et des substances chimiques , Humains , Plaque dentaire/microbiologie , Désinfection/méthodes , Détergents/pharmacologie , Appareils de prothèse dentaire/microbiologie , Test de matériaux , Produits de nettoyage pour appareils de prothèse dentaire/pharmacologie
11.
Anal Chem ; 96(33): 13588-13597, 2024 Aug 20.
Article de Anglais | MEDLINE | ID: mdl-39116295

RÉSUMÉ

The excellent versatility of 5-axis computer numerical control (CNC) micromilling has led to its application for prototyping NMR microcoils tailored to mass-limited samples (reducing development time and cost). However, vibrations during 5-axis milling can hinder the creation of complex 3D volume microcoils (i.e., solenoids and saddle coils). To address these limitations, a high-resolution NSCNC ELARA 4-axis milling machine was developed with the extra precision required for making complex 3D volume microcoils. Upon investigating the performance of resonators made with various copper-coated dielectrics, resonators with poly(methyl methacrylate) (PMMA) provided the best SNR/line shape. Thus, complex 1.7 mm microcoil designs were machined from Cu-coated PMMA. A milled 6.4 mm solenoid also provided 6.6× the total carbon signal for a 13C-labeled broccoli seed compared to a commercial inverse 5 mm NMR probe (demonstrating potential for larger coil designs). However, the manufacture of coils <1.7 mm with copper-coated PMMA rods was challenging as ∼0.5 mm of remaining PMMA was needed to retain their structural integrity. To manufacture smaller microcoils, both a solenoid and saddle coil (both with 1 mm O.D., 0.1 mm thick walls) were etched from Cu-coated glass capillaries using a UV picosecond laser that was mounted onto an NSCNC 5-axis MiRA7L. Both resonators showed excellent signal and identified a wide range of metabolites in a 13C-labeled algae extract, while the solenoid was further tested on two copepod egg sacs (∼4 µg of total sample). In summary, the flexibility to prototype complex microcoils in-house allows laboratories to tailor microcoils to specific mass-limited samples while avoiding the costs of cleanrooms.


Sujet(s)
Lasers , Spectroscopie par résonance magnétique , Poly(méthacrylate de méthyle) , Spectroscopie par résonance magnétique/instrumentation , Poly(méthacrylate de méthyle)/composition chimique , Cuivre/composition chimique
12.
Biol Pharm Bull ; 47(7): 1396-1404, 2024.
Article de Anglais | MEDLINE | ID: mdl-39085138

RÉSUMÉ

Estimation of the continuous hemodiafiltration (CHDF) clearance (CLCHDF) of ganciclovir (GCV) is crucial for achieving efficient treatment outcomes. Here, we aimed to clarify the contribution of diafiltration, adsorption, and hematocrit level to the CLCHDF of GCV in an in vitro CHDF model using three membranes: polyacrylonitrile and sodium methallyl sulfonate copolymer coated with polyethylenimine (AN69ST); polymethylmethacrylate (PMMA); and polysulfone (PS). In vitro CHDF was performed with effluent flow rates (Qe) of 800, 1500, and 3000 mL/h. The initial GCV concentration was 10 µg/mL while that of human serum albumin (HSA) was 0 or 5 g/dL. The CLCHDF, diafiltration rates, and adsorption rates were calculated. The whole blood-to-plasma ratio (R) of GCV for a hematocrit of 0.1 to 0.5 was determined using blood samples with 0.5 to 100 µg/mL of GCV. The in vitro CHDF experiment using AN69ST, PMMA, and PS membranes showed that the total CLCHDF values were almost the same as the Qe and not influenced by the HSA concentration. The diafiltration rate exceeded 88.1 ± 2.8% while the adsorption rate was lower than 9.4 ± 9.4% in all conditions. The R value was 1.89 ± 0.11 and was similar at all hematocrit levels and GCV concentrations. In conclusion, diafiltration mainly contributes to the CLCHDF of GCV, rather than adsorption. Hematocrit levels might not affect the relationship between the plasma and blood CLCHDF of GCV, and the CLCHDF of GCV can be estimated from the Qe and R, at least in vitro.


Sujet(s)
Résines acryliques , Ganciclovir , Hémodiafiltration , Humains , Hémodiafiltration/méthodes , Adsorption , Ganciclovir/pharmacocinétique , Ganciclovir/sang , Ganciclovir/administration et posologie , Hématocrite , Résines acryliques/composition chimique , Antiviraux/sang , Antiviraux/pharmacocinétique , Poly(méthacrylate de méthyle)/composition chimique , Polymères/composition chimique , Membrane artificielle
13.
Analyst ; 149(15): 3882-3890, 2024 Jul 22.
Article de Anglais | MEDLINE | ID: mdl-38973472

RÉSUMÉ

Nowadays, kidney dysfunction is a common health issue due to the modernized lifestyle. Even though medications are commercially available to treat kidney diseases, early diagnosis is crucial and challenging. Clinically, measuring urine creatinine and pH has gained significant interest as a way to diagnose kidney diseases early. In the present work, we attempted to develop a low-cost, robust, accurate and naked-eye colorimetric method to determine both creatinine levels and pH variations in artificial urine samples using a simple 3D-printed hybrid microfluidic device. Creatinine was detected by the incorporation of the traditional Jaffe test onto the hybrid paper-PMMA microfluidic device and pH (4-8) was measured by a simple anthocyanin test. Notably, the tests were established without employing any sophisticated or costly instrument clusters. The developed 3D-printed microfluidic probe showed a limit of detection (LOD) of 0.04 mM for creatinine over a concentration range of 1-10 mM, with a regression coefficient (R2) of 0.995 in laboratory conditions. Interestingly, the experimental data obtained with artificial urine exhibited a wide linear range from 0.1 mM to 5 mM under different pH values ranging from 4 to 8 in the presence of matrices commonly found in urine samples other than proteins, indicating the potential use of this method in pre-clinical analysis. Since the wide linear range of urine creatinine in artificial urine samples falls well below the clinically relevant concentrations in humans (0.07-0.27 mM), the developed lab-on-chip device is further suitable for clinical evaluation with proper ethical clearance. This 3D-printed hybrid microfluidic colorimetry-based creatinine detection and pH indicator platform can be beneficial in the healthcare sector due to the on-site testing capability, cost-effectiveness, ease of use, robustness, and instrument-free approach.


Sujet(s)
Créatinine , Laboratoires sur puces , Limite de détection , Papier , Poly(méthacrylate de méthyle) , Concentration en ions d'hydrogène , Créatinine/urine , Humains , Poly(méthacrylate de méthyle)/composition chimique , Colorimétrie/instrumentation , Colorimétrie/méthodes , Impression tridimensionnelle , Techniques d'analyse microfluidique/instrumentation , Techniques d'analyse microfluidique/méthodes
14.
Sci Prog ; 107(3): 368504241263484, 2024.
Article de Anglais | MEDLINE | ID: mdl-39043200

RÉSUMÉ

The limited physical and mechanical properties of polymethyl methacrylate (PMMA), the current gold standard, necessitates exploring improved denture base materials. While three-dimensional (3D) printing offers accuracy, efficiency, and patient comfort advantages, achieving superior mechanics in 3D-printed denture resins remains challenging despite good biocompatibility and esthetics. This review investigates the potential of innovative materials to address the limitations of 3D-printed denture base materials. Thus, this article is organized to provide a comprehensive overview of recent efforts to enhance 3D-printed denture base materials, highlighting advancements. It critically examines the impact of incorporating various nanoparticles (zirconia, titania, etc.) on these materials' physical and mechanical properties. Additionally, it delves into recent strategies for nanofiller surface treatment and biocompatibility evaluation and explores potential future directions for polymeric composites in denture applications. The review finds that adding nanoparticles significantly improves performance compared to unmodified resins, and properties can be extensively enhanced through specific modifications, particularly silanized nanoparticles. Optimizing 3D-printed denture acrylics requires a multifaceted approach, with future research prioritizing novel nanomaterials and surface modification techniques for a novel generation of superior performance, esthetically pleasing, and long-lasting dentures.


Sujet(s)
Bases d'appareil de prothèse dentaire , Impression tridimensionnelle , Humains , Nanoparticules/composition chimique , Matériaux biocompatibles/composition chimique , Poly(méthacrylate de méthyle)/composition chimique , Matériaux dentaires/composition chimique , Résines acryliques/composition chimique , Propriétés de surface
15.
Biomed Mater ; 19(5)2024 Aug 08.
Article de Anglais | MEDLINE | ID: mdl-39025111

RÉSUMÉ

Many kinds of human tumors, including breast carcinomas, frequently metastasize to the bone, making it prone to pathologic fractures. Surgical management of bone metastases ranges from the resection of metastases to bone repair. Current surgical methods for the repair of bone defects include the use of polymethyl methacrylate (PMMA)-based bone cements. A promising alternative material are bioactive glass (BG) particles that in addition to providing physical stability can also induce bone regeneration. Moreover, BGs doped with Fe2O3may also have a negative impact on tumor cells. Here, we tested the hypothesis that BGs can affect metastatic human breast cancer cells. To this end, we assessed the effects of different BG compositions with and without Fe2O3on metastatic human MDA-MB-231 breast cancer cellsin vitro. We found that all BGs tested impaired the viability and proliferation of breast cancer cells in a concentration-dependent manner. The anti-proliferative effects inversely correlated with BG particle size, and were in general less pronounced in mesenchymal stromal cells (MSCs) that served as a control. Moreover, Fe2O3-doped BGs were more potent inhibitors of tumor cell proliferation and metabolic activity than Fe2O3-free BG. Our data therefore indicate that BGs can affect human breast cancer cells more strongly than MSCs, and suggest that the presence of Fe2O3can potentiate anti-proliferative and anti-metabolic effects of BGs. Fe2O3-doped BGs thus have the potential to be used for the surgical management of metastatic bone lesions, and may in addition to their regenerative properties also allow the local control of bone metastases.


Sujet(s)
Tumeurs osseuses , Tumeurs du sein , Prolifération cellulaire , Survie cellulaire , Céramiques , Verre , Humains , Tumeurs du sein/anatomopathologie , Tumeurs du sein/métabolisme , Prolifération cellulaire/effets des médicaments et des substances chimiques , Verre/composition chimique , Femelle , Lignée cellulaire tumorale , Céramiques/composition chimique , Céramiques/pharmacologie , Tumeurs osseuses/secondaire , Tumeurs osseuses/métabolisme , Survie cellulaire/effets des médicaments et des substances chimiques , Test de matériaux , Fer/composition chimique , Matériaux biocompatibles/composition chimique , Matériaux biocompatibles/pharmacologie , Cellules souches mésenchymateuses , Composés du fer III/composition chimique , Poly(méthacrylate de méthyle)/composition chimique , Taille de particule , Ciments osseux/composition chimique , Ciments osseux/pharmacologie
16.
ACS Appl Mater Interfaces ; 16(31): 40767-40786, 2024 Aug 07.
Article de Anglais | MEDLINE | ID: mdl-39047263

RÉSUMÉ

A modular and 3D compartmentalized microfluidic system with electrospun porous membranes (PMs) for epithelialized organ-on-a-chip systems is presented. Our novel approach involves direct deposition of polymer nanofibers onto a patterned poly(methyl methacrylate) (PMMA) substrate using electrospinning, resulting in an integrated PM within the microfluidic chip. The in situ deposition of the PM eliminates the need for additional assembly processes. To demonstrate the high throughput membrane integration capability of our approach, we successfully deposited nanofibers onto various chip designs with complex microfluidic planar structures and expanded dimensions. We characterized and tested the fully PMMA chip by growing an epithelial monolayer using the Caco-2 cell line to study drug permeability. A comprehensive analysis of the bulk and surface properties of the membrane's fibers made of PMMA and polystyrene (PS) was conducted to determine the polymer with the best performance for cell culture and drug transport applications. The PMMA-based membrane, with a PMMA/PVP ratio of 5:1, allowed for the fabrication of a uniform membrane structure along the aligned nanofibers. By modulating the fiber diameter and total thickness of the membrane, we could adjust the membrane's porosity for specific cell culture applications. The PMMA-PVP nanofibers exhibited a low polydispersity index value, indicating monodispersed nanofibers and a more homogeneous and uniform fiber network. Both types of membranes demonstrated excellent mechanical integrity under medium perfusion flow rates. However, the PMMA-PVP composition offered a tailored porous structure with modulable porosity based on the fiber diameter and thickness. Our developed platform enables dynamic in vitro modeling of the epithelial barrier and has applications in drug transport and in vitro microphysiological systems.


Sujet(s)
Laboratoires sur puces , Nanofibres , Poly(méthacrylate de méthyle) , Humains , Cellules Caco-2 , Porosité , Poly(méthacrylate de méthyle)/composition chimique , Nanofibres/composition chimique , Membrane artificielle , Polystyrènes/composition chimique
17.
PLoS One ; 19(7): e0299757, 2024.
Article de Anglais | MEDLINE | ID: mdl-39028721

RÉSUMÉ

Acute and chronic inflammation are common in patients with end-stage kidney disease (ESKD). So, the adsorption of pro-inflammatory cytokines by the hollow fiber of the dialysis membrane has been expected to modify the inflammatory dysregulation in ESKD patients. However, it remains to be determined in detail what molecules of fiber materials can preferably adsorb proteins from the circulating circuit. We aimed this study to analyze directly the adsorbed proteins in the polymethyl methacrylate (PMMA) and polyethersulfone (PES) membranes in patients on predilution online hemodiafiltration (OL-HDF). To compare the adsorbed proteins in the PMMA and PES hemodiafilters membrane, we initially performed predilution OL-HDF using the PES (MFX-25Seco) membrane while then switched to the PMMA (PMF™-A) membrane under the same condition in three patients. We extracted proteins from the collected hemodiafilters by extraction, then SDS-PAGE of the extracted sample, protein isolation, in-gel tryptic digestion, and nano-LC MS/MS analyses. The concentrations of adsorbed proteins from the PMMA and PES membrane extracts were 35.6±7.9 µg/µL and 26.1±9.2 µg/µL. SDS-PAGE analysis revealed distinct variations of adsorbed proteins mainly in the molecular weight between 10 to 25 kDa. By tryptic gel digestion and mass spectrometric analysis, the PMMA membrane exhibited higher adsorptions of ß2 microglobulin, dermcidin, retinol-binding protein-4, and lambda-1 light chain than those from the PES membrane. In contrast, amyloid A-1 protein was adsorbed more potently in the PES membrane. Western blot analyses revealed that the PMMA membrane adsorbed interleukin-6 (IL-6) approximately 5 to 118 times compared to the PES membrane. These findings suggest that PMMA-based OL-HDF therapy may be useful in controlling inflammatory status in ESKD patients.


Sujet(s)
Hémodiafiltration , Membrane artificielle , Polymères , Poly(méthacrylate de méthyle) , Sulfones , Humains , Hémodiafiltration/méthodes , Hémodiafiltration/instrumentation , Poly(méthacrylate de méthyle)/composition chimique , Adsorption , Sulfones/composition chimique , Polymères/composition chimique , Mâle , Protéines du sang/composition chimique , Protéines du sang/analyse , Adulte d'âge moyen , Défaillance rénale chronique/thérapie , Défaillance rénale chronique/sang , Femelle , Sujet âgé , Spectrométrie de masse en tandem/méthodes
18.
ACS Appl Bio Mater ; 7(7): 4510-4518, 2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-38950150

RÉSUMÉ

Fungal proliferation can lead to adverse effects for human health, due to the production of pathogenic and allergenic toxins and also through the creation of fungal biofilms on sensitive surfaces (i.e., medical equipment). On top of that, food spoilage from fungal activity is a major issue, with food losses exceeding 30% annually. In this study, the effect of the surface micro- and nanotopography, material (aluminum, Al, and poly(methyl methacrylate), PMMA), and wettability against Aspergillus awamori is investigated. The fungal activity is monitored using dynamic conditions by immersing the surfaces inside fungal spore-containing suspensions and measuring the fungal biomass growth, while the surfaces with the optimum antifungal properties are also evaluated by placing them near spore suspensions of A. awamori on agar plates. Al- and PMMA-based superhydrophobic surfaces demonstrate a passive-like antifungal profile, and the fungal growth is significantly reduced (1.6-2.2 times lower biomass). On the other hand, superhydrophilic PMMA surfaces enhance fungal proliferation, resulting in a 2.6 times higher fungal total dry weight. In addition, superhydrophobic surfaces of both materials exhibit antifouling and antiadhesive properties, whereas both superhydrophobic surfaces also create an "inhibition" zone against the growth of A. awamori when tested on agar plates.


Sujet(s)
Aspergillus , Matériaux biocompatibles , Test de matériaux , Taille de particule , Propriétés de surface , Mouillabilité , Matériaux biocompatibles/composition chimique , Matériaux biocompatibles/pharmacologie , Antifongiques/pharmacologie , Antifongiques/composition chimique , Poly(méthacrylate de méthyle)/composition chimique , Poly(méthacrylate de méthyle)/pharmacologie , Prolifération cellulaire/effets des médicaments et des substances chimiques
19.
Lab Chip ; 24(16): 3958-3972, 2024 Aug 06.
Article de Anglais | MEDLINE | ID: mdl-39015046

RÉSUMÉ

Diabetes is a common chronic metabolic disease with a wide range of clinical symptoms and consequences and one of the main causes of death. For the management of diabetes, painless and continuous interstitial fluid (ISF) glucose monitoring is ideal. Here, we demonstrate continuous diabetes monitoring using an integrated microneedle (MN) biosensor with an emergency alert system. MNs are a novel technique in the field of biomedical engineering because of their ability to analyze bioinformation with minimal invasion. In this work we developed a poly(methyl methacrylate) (PMMA) based MN glucose sensor. The device was produced by the 3D printing technique, microfabrication, electrodeposition, and enzyme immobilization step. The in vitro test for the glucose MN sensor showed a linear range from 1.5 to 14 mM with a sensitivity of 1.51 µA mM-1, limit of detection (LOD) of 0.35 mM and good selectivity. Highly repeatable sensing is observed with good reproducibility. The interference-free detection of glucose in the presence of physiologically relevant concentrations of ascorbic acid, uric acid, and mannose is demonstrated, along with the operational stability of the array. After resolving the biofouling consequences linked to on-body sensing, this MN platform would be appealing for minimally invasive electrochemical glucose monitoring. An alert is sent to confidants via email or SMS when the values are abnormal. The application is also able to display the recorded values in the form of a graph to help determine the state of health of the user over a period of time. It can be concluded that continuous monitoring and an emergency alert system are important for keeping an eye on diabetic patients and can send alert in case of an abnormal situation of the patient.


Sujet(s)
Techniques de biocapteur , Liquide extracellulaire , Glucose , Aiguilles , Techniques de biocapteur/instrumentation , Liquide extracellulaire/composition chimique , Humains , Glucose/analyse , Glucose/métabolisme , Électrodes , Hypoglycémie/diagnostic , Limite de détection , Poly(méthacrylate de méthyle)/composition chimique
20.
Int J Mol Sci ; 25(13)2024 Jun 21.
Article de Anglais | MEDLINE | ID: mdl-38999953

RÉSUMÉ

Hybrid scaffolds that are based on PLA and PLA/PMMA with 75/25, 50/50, and 25/75 weight ratios and functionalized with 10 wt.% of bioglass nanoparticles (n-BG) were developed using an electrospinning technique with a chloroform/dimethylformamide mixture in a 9:1 ratio for bone tissue engineering applications. Neat PLA and PLA/PMMA hybrid scaffolds were developed successfully through a (CF/DMF) solvent system, obtaining a random fiber deposition that generated a porous structure with pore interconnectivity. However, with the solvent system used, it was not possible to generate fibers in the case of the neat PMMA sample. With the increase in the amount of PMMA in PLA/PMMA ratios, the fiber diameter of hybrid scaffolds decreases, and the defects (beads) in the fiber structure increase; these beads are associated with a nanoparticle agglomeration, that could be related to a low interaction between n-BG and the polymer matrix. The Young's modulus of PLA/PMMA/n-BG decreases by 34 and 80%, indicating more flexible behavior compared to neat PLA. The PLA/PMMA/n-BG scaffolds showed a bioactive property related to the presence of hydroxyapatite crystals in the fiber surface after 28 days of immersion in a Simulated Body Fluids solution (SBF). In addition, the hydrolytic degradation process of PLA/PMMA/n-BG, analyzed after 35 days of immersion in a phosphate-buffered saline solution (PBS), was less than that of the pure PLA. The in vitro analysis using an HBOF-1.19 cell line indicated that the PLA/PMMA/n-BG scaffold showed good cell viability and was able to promote cell proliferation after 7 days. On the other hand, the in vivo biocompatibility evaluated via a subdermal model in BALC male mice corroborated the good behavior of the scaffolds in avoiding the generation of a cytotoxic effect and being able to enhance the healing process, suggesting that the materials are suitable for potential applications in tissue engineering.


Sujet(s)
Céramiques , Nanoparticules , Polyesters , Poly(méthacrylate de méthyle) , Ingénierie tissulaire , Structures d'échafaudage tissulaires , Ingénierie tissulaire/méthodes , Polyesters/composition chimique , Poly(méthacrylate de méthyle)/composition chimique , Structures d'échafaudage tissulaires/composition chimique , Céramiques/composition chimique , Céramiques/pharmacologie , Nanoparticules/composition chimique , Animaux , Souris , Os et tissu osseux/effets des médicaments et des substances chimiques , Matériaux biocompatibles/composition chimique , Matériaux biocompatibles/pharmacologie , Humains , Lignée cellulaire
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE