Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 14.965
Filtrer
1.
Zhonghua Nei Ke Za Zhi ; 63(6): 550-559, 2024 Jun 01.
Article de Chinois | MEDLINE | ID: mdl-38825924

RÉSUMÉ

Thyroid nodule and cervical lymph node biopsy is the main clinical method for evaluating the condition and determining the follow-up treatment plan. The literature on thyroid nodule puncture predominantly focuses on thyroid fine needle puncture, and there are limited systematic articles on coarse needle aspiration for thyroid-related diseases and needle biopsy of thyroid-related cervical lymph node diseases. However, this shortage of articles does not reflect the diagnostic value of coarse needle aspiration in thyroid biopsy and cervical lymph node-related diseases. Currently, different departments of many hospitals in China are conducting or planning to perform needle biopsy of thyroid and cervical lymph node-related diseases to improve the standardization and safety of related operations. Standardization is needed for the indications, contraindications, perioperative period, postoperative complications management, puncture specimen processing, and related genetic analysis of thyroid and cervical lymph node puncture. For this purpose, Interventional Ultrasound Committee of Chinese College of Interventionalists organized a panel of domestic experts in the field of thyroid diseases to discuss and formulate a consensus. Based on the latest research progress, combined with the clinical realities in China, this Expert Consensus on Ultrasound Guided Thyroid and Neck Lymph Node Puncture (2023 edition) is released.


Sujet(s)
Noeuds lymphatiques , Cou , Glande thyroide , Humains , Noeuds lymphatiques/imagerie diagnostique , Noeuds lymphatiques/anatomopathologie , Glande thyroide/imagerie diagnostique , Glande thyroide/anatomopathologie , Chine , Cytoponction/méthodes , Nodule thyroïdien/imagerie diagnostique , Nodule thyroïdien/anatomopathologie , Consensus , Échographie interventionnelle/méthodes , Ponctions/méthodes
2.
J Craniofac Surg ; 35(4): 1201-1204, 2024 Jun 01.
Article de Anglais | MEDLINE | ID: mdl-38829146

RÉSUMÉ

OBJECTIVE: This study aimed to investigate the feasibility, safety, and efficacy of the neuroendoscopy-assisted entire-process visualization technique (NEAEVT) of ventricular puncture for external ventricular drainage. METHODS: Eighty-eight patients with cerebral hemorrhage who underwent unilateral ventricular puncture for external ventricular drainage in our hospital from June 2021 to June 2023 were analyzed. Patients were grouped according to puncture technique: NEAEVT (30 patients), freehand (30 patients), and laser-navigation-assisted (28 patients). Operation time, drainage tube placement, and catheter-related hemorrhage incidence were compared between the groups. RESULTS: Mean operation time significantly differed between the freehand, NEAEVT, and laser-assisted groups (17.07, 18.37, and 34.04 min, respectively; P <0.0001). The position of the drainage tube was optimal or adequate in all patients of the NEAEVT group; optimal/adequate positioning was achieved in 80% of the freehand group. No catheter-related hemorrhage occurred in the NEAEVT group. Three freehand group patients and 2 laser-assisted group patients experienced catheter-related hemorrhage. CONCLUSION: The NEAEVT of ventricular puncture is accurate and achieves ventricular drainage without significantly increasing surgical trauma, operation time, or incidence of hemorrhage.


Sujet(s)
Ventricules cérébraux , Drainage , Neuroendoscopie , Durée opératoire , Ponctions , Humains , Mâle , Femelle , Drainage/méthodes , Adulte d'âge moyen , Neuroendoscopie/méthodes , Sujet âgé , Ventricules cérébraux/chirurgie , Ventricules cérébraux/imagerie diagnostique , Adulte , Hémorragie cérébrale/chirurgie , Études de faisabilité , Ventriculostomie/méthodes , Études rétrospectives , Résultat thérapeutique
3.
J Vis Exp ; (207)2024 May 24.
Article de Anglais | MEDLINE | ID: mdl-38856226

RÉSUMÉ

Hemostasis, the process of normal physiological control of vascular damage, is fundamental to human life. We all suffer minor cuts and puncture wounds from time to time. In hemostasis, self-limiting platelet aggregation leads to the formation of a structured thrombus in which bleeding cessation comes from capping the hole from the outside. Detailed characterization of this structure could lead to distinctions between hemostasis and thrombosis, a case of excessive platelet aggregation leading to occlusive clotting. An imaging-based approach to puncture wound thrombus structure is presented here that draws upon the ability of thin-section electron microscopy to visualize the interior of hemostatic thrombi. The most basic step in any imaging-based experimental protocol is good sample preparation. The protocol provides detailed procedures for preparing puncture wounds and platelet-rich thrombi in mice for subsequent electron microscopy. A detailed procedure is given for in situ fixation of the forming puncture wound thrombus and its subsequent processing for staining and embedding for electron microscopy. Electron microscopy is presented as the end imaging technique because of its ability, when combined with sequential sectioning, to visualize the details of the thrombus interior at high resolution. As an imaging method, electron microscopy gives unbiased sampling and an experimental output that scales from nanometer to millimeters in 2 or 3 dimensions. Appropriate freeware electron microscopy software is cited that will support wide-area electron microscopy in which hundreds of frames can be blended to give nanometer-scale imaging of entire puncture wound thrombi cross-sections. Hence, any subregion of the image file can be placed easily into the context of the full cross-section.


Sujet(s)
Microscopie électronique , Thrombose , Animaux , Souris , Microscopie électronique/méthodes , Thrombose/anatomopathologie , Hémostase , Ponctions/méthodes
4.
J Coll Physicians Surg Pak ; 34(6): 717-722, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38840358

RÉSUMÉ

OBJECTIVE: To determine the clinical applicability of the modified concentric cannula technique (CCT), focusing on the duration of the arthrocentesis, the number of reposition of cannula, and the occurrence of complications. STUDY DESIGN: Descriptive study. Place and Duration of the Study: Department of Oral and Maxillofacial Surgery, Ankara Yildirim Beyazit University, Ankara, Turkiye, between September 2021 and May 2022. METHODOLOGY: Forty patients with Wilkes III temporomandibular joints (TMJ) internal derangement were identified and 13 patients who met the inclusion criteria were reviewed. The main outcomes regarding the clinical applicability of modified CCT included the duration of arthrocentesis, the number of reposition of cannula, and the occurrence of complications. RESULTS: The values of maximum mouth opening (MMO) without pain and MMO without assistance measured in the immediate postoperative period and at the 4th and 8th postoperative weeks were found to be significantly higher than the pre-arthrocentesis values. The values of MMO with assistance measured in the immediate postoperative period and at the 8th postoperative week were also significantly higher than the baseline values. Compared with preoperative values, notable decreases in pain scores were observed at the 4th (p = 0.003) and 8th (p = 0.002) postoperative weeks. The assessment of the jaw dysfunction also revealed significantly lower scores at the 4th (p = 0.024) and 8th (p <0.001) postoperative weeks. CONCLUSION: Modified CCT of arthrocentesis substantially decreased pain and improved mandibular functions in patients with internal derangement of TMJ. Additionally, this technique could be performed with a reduced number of cannula relocations and required a shorter operative time even with the use of a higher irrigation volume during the lavage procedure. KEY WORDS: Arthrocentesis, Temporomandibular joint disorder, Temporomandibular joint.


Sujet(s)
Arthrocentèse , Troubles de l'articulation temporomandibulaire , Humains , Arthrocentèse/méthodes , Mâle , Femelle , Troubles de l'articulation temporomandibulaire/chirurgie , Adulte , Adulte d'âge moyen , Ponctions/méthodes , Aiguilles , Résultat thérapeutique , Jeune adulte , Articulation temporomandibulaire/chirurgie , Amplitude articulaire , Canule
5.
Ann Card Anaesth ; 27(1): 58-60, 2024 Jan 01.
Article de Anglais | MEDLINE | ID: mdl-38722123

RÉSUMÉ

ABSTRACT: The transversus thoracic muscle plane (TTP) block is gaining widespread recognition in cardiac surgery, particularly in facilitating fast-tracking. Here, we report a case of inadvertent puncture of the right ventricle (RV) during the administration of ultra sound-guided (USG) TTP block in a 3-year-old child posted for atrial septal defect (ASD) closure and mitral valve repair. We also discuss the care that should be taken to avoid such complications and such cases require extra caution during TTP block.


Sujet(s)
Ventricules cardiaques , Humains , Ventricules cardiaques/imagerie diagnostique , Enfant d'âge préscolaire , Communications interauriculaires/chirurgie , Mâle , Échographie interventionnelle/méthodes , Bloc nerveux/méthodes , Bloc nerveux/effets indésirables , Ponctions/effets indésirables
6.
Urolithiasis ; 52(1): 75, 2024 May 16.
Article de Anglais | MEDLINE | ID: mdl-38753168

RÉSUMÉ

This study was designed to evaluate the non-inferiority of ultrasound puncture followed by endoscopically guided tract dilatation compared to the standard fluoroscopy-guided PCNL. Forty patients with non-opaque kidney stones eligible for PCNL were randomly divided into two groups. The standard fluoroscopy-guided PCNL using the Amplatz dilator was performed in the XRAY group. In the SONO group, the Kidney was punctured under an ultrasound guide followed by tract dilatation using a combination of the Amplatz dilator based on the tract length and an endoscopically guided tract dilatation using a bi-prong forceps in cases of short-advancement. The primary outcome was successful access. In 90% of cases in the XRAY and 95% in the SONO group access dilatation process was performed uneventfully at the first attempt (p = 0.5). In 45% of cases in the SONO group, bi-prong forceps were used as salvage for short-advancement. In one case in the X-ray group over-advancement occurred. One month after surgery, the stone-free rate on the CT-scan was 75% for the X-ray group and 85% for the SONO group (p = 0.4). There were no significant differences in operation time, hospitalization duration, transfusion, or complication rates between the two groups. We conclude that ultrasound-guided renal puncture, followed by endoscopically guided tract dilatation can achieve a high success rate similar to X-ray-guided PCNL while avoiding the harmful effects of radiation exposure and the risk of over-advancement.


Sujet(s)
Dilatation , Calculs rénaux , Néphrolithotomie percutanée , Ponctions , Échographie interventionnelle , Humains , Radioscopie/méthodes , Calculs rénaux/chirurgie , Calculs rénaux/imagerie diagnostique , Néphrolithotomie percutanée/méthodes , Néphrolithotomie percutanée/effets indésirables , Néphrolithotomie percutanée/instrumentation , Mâle , Femelle , Adulte d'âge moyen , Ponctions/méthodes , Dilatation/méthodes , Dilatation/instrumentation , Adulte , Rein/chirurgie , Rein/imagerie diagnostique , Résultat thérapeutique , Sujet âgé
7.
Int J Cardiol ; 407: 132113, 2024 Jul 15.
Article de Anglais | MEDLINE | ID: mdl-38697398

RÉSUMÉ

BACKGROUND: Axillary vein puncture (AVP) is a valid alternative to Subclavan vein puncture for leads insertion in cardiac implantable electronic device implantation, that may reduce acute and delayed complications. Very few data are available about ICD recipients. A simplified AVP technique is described. METHODS: All the patients who consecutively underwent "de novo" ICD implantation, from March 2006 to December 2020 at the University of Verona, were considered. Leads insertion was routinely performed through an AVP, according to a simplified technique. Outcome and complications have been retrospectively analyzed. RESULTS: The study population consisted of 1711 consecutive patients. Out of 1711 patients, 38 (2.2%) were excluded because they were implanted with Medtronic Sprint Fidelis lead. Out of 1673 ICD implantations, 963 (57.6%) were ICD plus cardiac resynchronization therapy, 434 (25.9%) were dual-chamber defibrillators, and 276 (16.5%) were single-chamber defibrillators, for a total of 3879 implanted leads. The AVP success rate was 99.4%. Acute complications occurred in 7/1673 (0.42%) patients. Lead failure (LF) occurred in 20/1673 (1.19%) patients. Comparing the group of patients with lead failure with the group without LF, the presence of three leads inside the vein was significantly associated with LF, and the multivariate analysis confirmed three leads in place as an independent predictor of LF. CONCLUSION: AVP, according to our simplified technique, is safe, effective, has a high success rate, and a very low complication rate. The incidence of LF was exceptionally low. The advantages of AVP are maintained over time in a population of ICD recipients.


Sujet(s)
Veine axillaire , Défibrillateurs implantables , Ponctions , Humains , Défibrillateurs implantables/effets indésirables , Mâle , Femelle , Études rétrospectives , Sujet âgé , Adulte d'âge moyen , Veine axillaire/imagerie diagnostique , Implantation de prothèse/méthodes , Implantation de prothèse/effets indésirables , Implantation de prothèse/instrumentation , Résultat thérapeutique , Facteurs temps
8.
Vestn Otorinolaringol ; 89(2): 15-20, 2024.
Article de Russe | MEDLINE | ID: mdl-38805458

RÉSUMÉ

OBJECTIVE: Optimization of the method of puncture treatment of acute bacterial maxillary sinusitis (ABMS) through the development of original devices for drainage of the maxillary sinus (MS). MATERIAL AND METHODS: Registration and comparative analysis of the results of puncture methods of treatment of 120 patients with ABMS using developed new original devices for drainage of MS with one channels and with two channels in comparison with the Kulikovsky's needle (KN) was carried out. Based on the results of the analysis, the effectiveness of the original devices was assessed. During the clinical study, patients were divided into two groups: in group I, patients underwent of the MS puncture using KN, in group II, using original devices. Groups I and II, depending on the absence or presence of a block of the natural anastomosis MS, was divided into subgroups A and B, respectively. After puncture of the MS, the pain syndrome was assessed by patients using Visual Analogue Scale (VAS) and by doctors - using Touch Visual Pain (TVP) scale. RESULTS: Our study showed that when puncturing the upper jaw with an original needle with one channels and with two channels, compared with the use of KN, there is a decrease in pain (the average VAS score was 1.5±0.3 and 1.7±0.3 points, respectively; the average TVP scale score was 0.9±0.2 and 1.8±0.3 points, respectively, the difference is significant, p≤0.05). Patients of subgroup IB were manipulated with two KN, patients of subgroup IIB manipulated using the original device with two channels without an additional needle (the average VAS score was 3.0±0.4 and 1.3±0.3 points, respectively; the average TVP scale score was 2.7±0.4 and 1.0±0.2 points, respectively, the difference is significant, p≤0.05). The doctors also assessed the devices used for puncture of the upper jaw. As a result of the study, the high efficiency and safety of using new original devices was established.


Sujet(s)
Sinusite maxillaire , Ponctions , Humains , Sinusite maxillaire/microbiologie , Sinusite maxillaire/thérapie , Sinusite maxillaire/diagnostic , Femelle , Mâle , Adulte , Ponctions/méthodes , Ponctions/instrumentation , Adulte d'âge moyen , Résultat thérapeutique , Drainage/méthodes , Drainage/instrumentation , Mesure de la douleur/méthodes , Sinus maxillaire/microbiologie , Sinus maxillaire/chirurgie , Maladie aigüe , Infections bactériennes/thérapie , Infections bactériennes/diagnostic
9.
Catheter Cardiovasc Interv ; 103(7): 1138-1144, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38695165

RÉSUMÉ

Following the introduction in the latest European and American guidelines, transcatheter edge-to-edge repair has become a valid alternative to surgery for ineligible patients. Among the available technologies, MitraClip (Abbott) was the first to be introduced for the percutaneous treatment of mitral regurgitation with the edge-to-edge technique. Although its safety and effectiveness has been widely demonstrated, the optimal procedural results are highly dependent from operators' experience. In this manuscript, we provide a full guide of advanced steering maneuvers of MitraClip in different scenarios of transseptal puncture.


Sujet(s)
Cathétérisme cardiaque , Sondes cardiaques , Insuffisance mitrale , Valve atrioventriculaire gauche , Ponctions , Humains , Cathétérisme cardiaque/effets indésirables , Cathétérisme cardiaque/instrumentation , Cathétérisme cardiaque/méthodes , Conception d'appareillage , Septum du coeur/chirurgie , Septum du coeur/imagerie diagnostique , Prothèse valvulaire cardiaque , Implantation de valve prothétique cardiaque/instrumentation , Implantation de valve prothétique cardiaque/effets indésirables , Valve atrioventriculaire gauche/chirurgie , Valve atrioventriculaire gauche/imagerie diagnostique , Valve atrioventriculaire gauche/physiopathologie , Insuffisance mitrale/chirurgie , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/physiopathologie , Résultat thérapeutique
11.
mBio ; 15(6): e0052124, 2024 Jun 12.
Article de Anglais | MEDLINE | ID: mdl-38700314

RÉSUMÉ

Despite its high mortality, specific and effective drugs for sepsis are lacking. Decoy receptor 3 (DcR3) is a potential biomarker for the progression of inflammatory diseases. The recombinant human DcR3-Fc chimera protein (DcR3.Fc) suppresses inflammatory responses in mice with sepsis, which is critical for improving survival. The Fc region can exert detrimental effects on the patient, and endogenous peptides are highly conducive to clinical application. However, the mechanisms underlying the effects of DcR3 on sepsis are unknown. Herein, we aimed to demonstrate that DcR3 may be beneficial in treating sepsis and investigated its mechanism of action. Recombinant DcR3 was obtained in vitro. Postoperative DcR3 treatment was performed in mouse models of lipopolysaccharide- and cecal ligation and puncture (CLP)-induced sepsis, and their underlying molecular mechanisms were explored. DcR3 inhibited sustained excessive inflammation in vitro, increased the survival rate, reduced the proinflammatory cytokine levels, changed the circulating immune cell composition, regulated the gut microbiota, and induced short-chain fatty acid synthesis in vivo. Thus, DcR3 protects against CLP-induced sepsis by inhibiting the inflammatory response and apoptosis. Our study provides valuable insights into the molecular mechanisms associated with the protective effects of DcR3 against sepsis, paving the way for future clinical studies. IMPORTANCE: Sepsis affects millions of hospitalized patients worldwide each year, but there are no sepsis-specific drugs, which makes sepsis therapies urgently needed. Suppression of excessive inflammatory responses is important for improving the survival of patients with sepsis. Our results demonstrate that DcR3 ameliorates sepsis in mice by attenuating systematic inflammation and modulating gut microbiota, and unveil the molecular mechanism underlying its anti-inflammatory effect.


Sujet(s)
Caecum , Modèles animaux de maladie humaine , Membre-6b de la superfamille des récepteurs au TNF , Sepsie , Animaux , Sepsie/traitement médicamenteux , Sepsie/microbiologie , Souris , Membre-6b de la superfamille des récepteurs au TNF/génétique , Membre-6b de la superfamille des récepteurs au TNF/métabolisme , Caecum/chirurgie , Humains , Ligature , Ponctions , Mâle , Souris de lignée C57BL , Microbiome gastro-intestinal , Cytokines/métabolisme , Lipopolysaccharides , Apoptose/effets des médicaments et des substances chimiques , Inflammation
12.
BMJ Case Rep ; 17(5)2024 May 13.
Article de Anglais | MEDLINE | ID: mdl-38740444

RÉSUMÉ

With the advancements in the medical field, many innovations in medical devices have happened. Using a surgical stapler to close the laryngectomy defect without opening the pharynx is particularly advantageous in a total laryngectomy (TL). However, performing the tracheoesophageal puncture (TEP) during stapler closure of the larynx has not been widely advocated, due to the fear of complications related to the procedure.We treated two male patients with advanced glottic malignancy who underwent a TL. To restore their ability to speak, we performed a primary TEP and immediate voice prosthesis placement. After the TEP, we closed the larynx using a stapler. The surgical technique used in this procedure has been thoroughly explained.The use of a surgical stapler for pharyngeal closure during a TL has several advantages, particularly with regard to the duration of surgery. The current techniques appear to be promising in reducing TEP-related complications during stapler-assisted laryngeal closure.


Sujet(s)
Tumeurs du larynx , Laryngectomie , Ponctions , Trachée , Humains , Mâle , Laryngectomie/méthodes , Laryngectomie/effets indésirables , Tumeurs du larynx/chirurgie , Ponctions/méthodes , Trachée/chirurgie , Oesophage/chirurgie , Agrafeuses chirurgicales , Sujet âgé , Adulte d'âge moyen , Larynx/chirurgie , Agrafage chirurgical/méthodes , Larynx artificiel
13.
Front Immunol ; 15: 1366955, 2024.
Article de Anglais | MEDLINE | ID: mdl-38562928

RÉSUMÉ

Background: Individual T cell responses vary significantly based on the microenvironment present at the time of immune response and on prior induced T cell memory. While the cecal ligation and puncture (CLP) model is the most commonly used murine sepsis model, the contribution of diverse T cell responses has not been explored. We defined T cell subset responses to CLP using single-cell RNA sequencing and examined the effects of prior induced T cell memory (Immune Education) on these responses. We hypothesized that Immune Education prior to CLP would alter T cell responses at the single cell level at a single, early post-CLP time point. Methods: Splenic T cells were isolated from C57BL/6 mice. Four cohorts were studied: Control, Immune-Educated, CLP, and Immune-Educated CLP. At age 8 weeks, Immune-Educated and Immune-Educated CLP mice received anti-CD3ϵ antibody; Control and CLP mice were administered an isotype control. CLP (two punctures with a 22-gauge needle) was performed at 12-13 weeks of life. Mice were sacrificed at baseline or 24-hours post-CLP. Unsupervised clustering of the transcriptome library identified six distinct T cell subsets: quiescent naïve CD4+, primed naïve CD4+, memory CD4+, naïve CD8+, activated CD8+, and CD8+ cytotoxic T cell subsets. T cell subset specific gene set enrichment analysis and Hurdle analysis for differentially expressed genes (DEGs) were performed. Results: T cell responses to CLP were not uniform - subsets of activated and suppressed T cells were identified. Immune Education augmented specific T cell subsets and led to genomic signatures favoring T cell survival in unoperated and CLP mice. Additionally, the combination of Immune Education and CLP effected the expression of genes related to T cell activity in ways that differed from CLP alone. Validating our finding that IL7R pathway markers were upregulated in Immune-Educated CLP mice, we found that Immune Education increased T cell surface IL7R expression in post-CLP mice. Conclusion: Immune Education enhanced the expression of genes associated with T cell survival in unoperated and CLP mice. Induction of memory T cell compartments via Immune Education combined with CLP may increase the model's concordance to human sepsis.


Sujet(s)
Ponctions , Sepsie , Souris , Humains , Animaux , Nourrisson , Survie cellulaire , Souris de lignée C57BL , Analyse de séquence d'ARN
18.
Europace ; 26(4)2024 Mar 30.
Article de Anglais | MEDLINE | ID: mdl-38619048

RÉSUMÉ

AIMS: A three-dimensional electroanatomic mapping system-guided transseptal puncture (3D-TSP), without fluoroscopy or echocardiography, has been only minimally reported. Indications for 3D-TSP remain unclear. Against this background, this study aims to establish a precise technique and create a workflow for validating and selecting eligible patients for fluoroless 3D-TSP. METHODS AND RESULTS: We developed a new methodology for 3D-TSP based on a unipolar electrogram derived from a transseptal needle tip (UEGM tip) in 102 patients (the derivation cohort) with intracardiac echocardiography (ICE) from March 2018 to February 2019. The apparent current of injury (COI) was recorded at the muscular limbus of the foramen ovalis (FO) on the UEGM tip (sinus rhythm: 2.57 ± 0.95 mV, atrial fibrillation: 1.92 ± 0.77 mV), which then disappeared or significantly reduced at the central FO. Changes in the COI, serving as a major criterion to establish a 3D-TSP workflow, proved to be the most valuable indicator for identifying the FO in 99% (101/102) of patients compared with three previous techniques (three minor criteria) of reduction in atrial unipolar or bipolar potential and FO protrusion. A total of 99.9% (1042/1043) patients in the validation cohort underwent successful 3D-TSP through the workflow from March 2019 to July 2023. Intracardiac echocardiography guidance was required for 6.6% (69/1042) of patients. All four criteria were met in 740 patients, resulting in a 100% pure fluoroless 3D-TSP success rate. CONCLUSION: In most patients, fluoroless 3D-TSP was successfully achieved using changes in the COI on the UEGM tip. Patients who met all four criteria were considered suitable for 3D-TSP, while those who met none required ICE guidance.


Sujet(s)
Fibrillation auriculaire , Techniques électrophysiologiques cardiaques , Imagerie tridimensionnelle , Ponctions , Humains , Mâle , Femelle , Fibrillation auriculaire/chirurgie , Fibrillation auriculaire/physiopathologie , Fibrillation auriculaire/diagnostic , Techniques électrophysiologiques cardiaques/méthodes , Sujet âgé , Adulte d'âge moyen , Ablation par cathéter/méthodes , Ablation par cathéter/instrumentation , Aiguilles , Septum du coeur/chirurgie , Septum du coeur/imagerie diagnostique , Flux de travaux , Échocardiographie
19.
Europace ; 26(5)2024 May 02.
Article de Anglais | MEDLINE | ID: mdl-38587311

RÉSUMÉ

AIMS: Pericardiocentesis is usually completed under fluoroscopy. The electroanatomic mapping (EAM) system allows visualizing puncture needle tip (NT) while displaying the electrogram recorded from NT, making it possible to obtain epicardial access (EA) independent of fluoroscopy. This study was designed to establish and validate a technique by which EA is obtained under guidance of three-dimensional (3D) EAM combined with NT electrogram. METHODS AND RESULTS: 3D shell of the heart was generated, and the NT was made trackable in the EAM system. Unipolar NT electrogram was continuously monitored. Penetration into pericardial sac was determined by an increase in NT potential amplitude and an injury current. A long guidewire of which the tip was also visible in the EAM system was advanced to confirm EA. Epicardial access was successfully obtained without complication in 13 pigs and 22 patients. In the animals, NT potential amplitude was 3.2 ± 1.0 mV when it was located in mediastinum, 5.2 ± 1.6 mV when in contact with fibrous pericardium, and 9.8 ± 2.8 mV after penetrating into pericardial sac (all P ≤ 0.001). In human subjects, it measured 1.54 ± 0.40 mV, 3.61 ± 1.08 mV, and 7.15 ± 2.88 mV, respectively (all P < 0.001). Fluoroscopy time decreased in every 4-5 cases (64 ± 15, 23 ± 17, and 0 s for animals 1-4, 5-8, 9-13, respectively, P = 0.01; 44 ± 23, 31 ± 18, 4±7 s for patients 1-7, 8-14, 15-22, respectively, P < 0.001). In five pigs and seven patients, EA was obtained without X-ray exposure. CONCLUSION: By tracking NT in the 3D EAM system and continuously monitoring the NT electrogram, it is feasible and safe to obtain EA with minimum or no fluoroscopic guidance.


Sujet(s)
Techniques électrophysiologiques cardiaques , Cartographie épicardique , Imagerie tridimensionnelle , Aiguilles , Péricarde , Humains , Mâle , Femelle , Animaux , Péricarde/imagerie diagnostique , Péricarde/chirurgie , Adulte d'âge moyen , Imagerie tridimensionnelle/méthodes , Sujet âgé , Techniques électrophysiologiques cardiaques/instrumentation , Techniques électrophysiologiques cardiaques/méthodes , Cartographie épicardique/méthodes , Péricardiocentèse/méthodes , Ponctions , Valeur prédictive des tests , Adulte , Suidae , Modèles animaux , Potentiels d'action , Sus scrofa , Radioscopie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE
...