Your browser doesn't support javascript.
loading
Montrer: 20 | 50 | 100
Résultats 1 - 20 de 955
Filtrer
1.
Catheter Cardiovasc Interv ; 104(2): 264-271, 2024 Aug.
Article de Anglais | MEDLINE | ID: mdl-38973374

RÉSUMÉ

Patients with functionally univentricular hearts are usually palliated surgically. There have been several reports of successful attempts to complete the Fontan procedure without surgery. The pathways created at the time of the preconditioning were largely reminiscent of the lateral tunnel Fontan. However, this approach is still confidentially limited to a small number of centers. In 2013, we designed a circuit that mimics the actual surgical technique of extracardiac total cavopulmonary connection to allow for transcatheter completion in an animal study. A polytetrafluoroethylene conduit was connected between the pulmonary artery and the inferior vena cava (IVC). The superior anastomosis was occluded to avoid flow between IVC and superior vena cava (SVC). The conduit was connected to the right atrium (RA) and a large fenestration was created to allow free flow from the IVC to the RA. Extrapolating our approach, a center reported the successful transcatheter completion of an extracardiac Fontan in a 6-year-old child. However, this technique is not directly transposable to our population of patients who require preconditioning in infancy. We report here an innovative extension of this technique that may allow preparing patients in infancy, ideally at the time of the Glenn in the future, to receive an extracardiac Fontan at 2 years/11 kg without additional surgery.


Sujet(s)
Cathétérisme cardiaque , Procédure de Fontan , Cardiopathies congénitales , Procédure de Fontan/effets indésirables , Cathétérisme cardiaque/instrumentation , Humains , Cardiopathies congénitales/chirurgie , Cardiopathies congénitales/physiopathologie , Cardiopathies congénitales/imagerie diagnostique , Artère pulmonaire/chirurgie , Artère pulmonaire/physiopathologie , Artère pulmonaire/imagerie diagnostique , Veine cave inférieure/imagerie diagnostique , Veine cave inférieure/chirurgie , Veine cave inférieure/physiopathologie , Polytétrafluoroéthylène , Cœur univentriculaire/chirurgie , Cœur univentriculaire/physiopathologie , Cœur univentriculaire/imagerie diagnostique , Conception de prothèse , Résultat thérapeutique , Hémodynamique , Animaux , Prothèse vasculaire
2.
Curr Opin Crit Care ; 30(3): 260-267, 2024 06 01.
Article de Anglais | MEDLINE | ID: mdl-38690955

RÉSUMÉ

PURPOSE OF REVIEW: Venous pressure is an often-unrecognized cause of patient morbidity. However, bedside assessment of PV is challenging. We review the clinical significance of venous pressure measurement, existing techniques, and introduce the Venous Excess Ultrasound (VExUS) Score as a novel approach using doppler ultrasound to assess venous pressure. RECENT FINDINGS: Studies show clear associations between elevated venous pressure and adverse outcomes in critically ill patients. Current venous pressure measurement techniques include physical examination, right heart catheterization (RHC), two-dimensional ultrasound, and a variety of labor-intensive research-focused physiological maneuvers. Each of these techniques have specific shortcomings, limiting their clinical utility. To address these gaps, Beaubien-Souligny et al. introduced the VExUS Score, a novel doppler ultrasound-based method that integrates IVC diameter with doppler measurements of the hepatic, portal, and renal veins to generate a venous congestion assesment. Studies show strong correlations between VExUS score and RHC measurements, and well as an association between VExUS score and improvement in cardiorenal acute kidney injury, diuretic response, and fluid status shifts. However, studies in noncardiac populations have been small, heterogenous, and inconclusive. SUMMARY: Early studies evaluating the use of doppler ultrasound to assess venous congestion show promise, but further research is needed in diverse patient populations and clinical settings.


Sujet(s)
Échographie-doppler , Humains , Échographie-doppler/méthodes , Maladie grave , Pression veineuse/physiologie , Veine cave inférieure/imagerie diagnostique , Veine cave inférieure/physiopathologie , Monitorage physiologique/méthodes , Soins de réanimation/méthodes
3.
Ann Biomed Eng ; 52(9): 2440-2456, 2024 Sep.
Article de Anglais | MEDLINE | ID: mdl-38753109

RÉSUMÉ

The hemodynamics in Fontan patients with single ventricles rely on favorable flow and energetics, especially in the absence of a subpulmonary ventricle. Age-related changes in energetics for extracardiac and lateral tunnel Fontan procedures are not well understood. Vorticity (VOR) and viscous dissipation rate (VDR) are two descriptors that can provide insights into flow dynamics and dissipative areas in Fontan pathways, potentially contributing to power loss. This study examined power loss and its correlation with spatio-temporal flow descriptors (vorticity and VDR). Data from 414 Fontan patients were used to establish a relationship between the superior vena cava (SVC) to inferior vena cava (IVC) flow ratio and age. Computational flow modeling was conducted for both extracardiac conduits (ECC, n = 16) and lateral tunnels (LT, n = 25) at different caval inflow ratios of 2, 1, and 0.5 that corresponded with ages 3, 8, and 15+. In both cohorts, vorticity and VDR correlated well with PL, but ECC cohort exhibited a slightly stronger correlation for PL-VOR (>0.83) and PL-VDR (>0.89) than that for LT cohort (>0.76 and > 0.77, respectively) at all ages. Our data also suggested that absolute and indexed PL increase (p < 0.02) non-linearly as caval inflow changes with age and are highly patient-specific. Comparison of indexed power loss between our ECC and LT cohort showed that while ECC had a slightly higher median PL for all 3 caval inflow ratio examined (3.3, 8.3, 15.3) as opposed to (2.7, 7.6, 14.8), these differences were statistically non-significant. Lastly, there was a consistent rise in pressure gradient across the TCPC with age-related increase in IVC flows for both ECC and LT Fontan patient cohort. Our study provided hemodynamic insights into Fontan energetics and how they are impacted by age-dependent change in caval inflow. This workflow may help assess the long-term sustainability of the Fontan circulation and inform the design of more efficient Fontan conduits.


Sujet(s)
Procédure de Fontan , Modèles cardiovasculaires , Humains , Enfant , Enfant d'âge préscolaire , Adolescent , Mâle , Femelle , Veine cave supérieure/physiopathologie , Veine cave supérieure/physiologie , Hémodynamique , Veine cave inférieure/physiopathologie , Phénomènes biomécaniques , Jeune adulte , Vieillissement/physiologie , Adulte
4.
Cardiorenal Med ; 14(1): 350-374, 2024.
Article de Anglais | MEDLINE | ID: mdl-38815571

RÉSUMÉ

BACKGROUND: Congestion, marked by elevated cardiac filling pressures and their repercussions, is a contributing factor to morbidity and mortality in heart failure and critical illness. Relying on traditional methods for bedside evaluation often leads to inadequate decongestion and increased hospital readmissions. Point-of-care ultrasound (POCUS), particularly multi-organ POCUS, including the Venous Excess Ultrasound (VExUS) score, offers a promising approach in this scenario. VExUS enables the quantification of systemic venous congestion, aiding in fluid overload states by assessing inferior vena cava and venous Doppler waveforms. SUMMARY: This comprehensive review delves into the latest developments in comprehending and evaluating congestion, shedding light on technical intricacies to enhance the effective application of VExUS. Recent studies emphasize the importance of evaluating signs of hemodynamic congestion before administering intravenous fluids, highlighting the concept of "fluid tolerance." Moreover, VExUS-guided decongestion significantly improves decongestion rates in acute decompensated heart failure patients with acute kidney injury. Newer studies also highlight the prognostic implications of VExUS in the general ICU cohorts not confining to cardiac surgery patients. However, performing VExUS without understanding technical pitfalls may lead to clinical errors. Technical considerations in performing VExUS include nuances related to inferior vena cava and internal jugular vein ultrasound and familiarity with Doppler principles, optimal settings, and artifacts. Additionally, local structural alterations such as those seen in liver and kidney disease impact Doppler waveforms, emphasizing the need for careful interpretation. KEY MESSAGE: Overall, VExUS presents a valuable tool for assessing congestion and guiding management, provided clinicians are familiar with its technical complexities and interpret findings judiciously.


Sujet(s)
Défaillance cardiaque , Hyperhémie , Veine cave inférieure , Humains , Veine cave inférieure/imagerie diagnostique , Veine cave inférieure/physiopathologie , Défaillance cardiaque/physiopathologie , Hyperhémie/physiopathologie , Systèmes automatisés lit malade , Échographie/méthodes , Hémodynamique/physiologie
5.
Echocardiography ; 41(6): e15850, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38818775

RÉSUMÉ

BACKGROUND: Accurately stratifying patients with pulmonary arterial hypertension (PAH) is very important, and traditional risk scores still have internal heterogeneity. This study aimed to construct a risk stratification model that can accurately identify clinical worsening (CW) events in conventional low-intermediate risk patients with pulmonary hypertension under targeted drug treatment by using echocardiographic parameters. METHODS: This study is a single-center, prospective study, including 105 PAH patients who underwent regular follow-up at Guangdong Provincial People's Hospital from October 2021 to April 2023. The primary endpoint was the occurrence of CW, including death, hospitalization due to pulmonary hypertension, escalation of targeted drug therapy, and worsening of PAH. The predictive value of the echocardiography-based three-strata risk model was assessed using Kaplan-Meier curves and COX regression analysis. RESULTS: A total of 98 PAH patients were ultimately included in this study. The median follow-up duration was 26 months (range 7-28 months). The echocardiography-based three-strata model included the ratio of tricuspid annular plane systolic excursion and pulmonary artery systolic pressure (TAPSE/PASP) and inferior vena cava (IVC). The echocardiography-based three-strata model had higher diagnostic value (C-index = .76) compared to the 2022 ESC/ERS three-strata model and four-strata model (C-index = .66 and C-index = .61, respectively). PAH patients with lower TAPSE/PASP and wider IVC showed a higher CW rate compared to patients with higher TAPSE/PASP and normal IVC (HR = 15.1, 95%CI:4.4-51.9, p < .001). CONCLUSION: The echocardiography-based three-strata model based on TAPSE/PASP and IVC can effectively improve the stratification of low-intermediate risk PAH patients under targeted treatment.


Sujet(s)
Échocardiographie , Ventricules cardiaques , Artère pulmonaire , Veine cave inférieure , Humains , Mâle , Femelle , Échocardiographie/méthodes , Adulte d'âge moyen , Études prospectives , Appréciation des risques/méthodes , Ventricules cardiaques/imagerie diagnostique , Ventricules cardiaques/physiopathologie , Artère pulmonaire/imagerie diagnostique , Artère pulmonaire/physiopathologie , Veine cave inférieure/imagerie diagnostique , Veine cave inférieure/physiopathologie , Adulte , Hypertension artérielle pulmonaire/physiopathologie , Hypertension artérielle pulmonaire/traitement médicamenteux , Hypertension artérielle pulmonaire/complications , Hypertension pulmonaire/physiopathologie , Hypertension pulmonaire/complications , Études de suivi
6.
Anaesth Crit Care Pain Med ; 43(3): 101370, 2024 Jun.
Article de Anglais | MEDLINE | ID: mdl-38462160

RÉSUMÉ

BACKGROUND: In the intensive care unit (ICU) patients, fluid overload and congestion are associated with worse outcomes. Because of the heterogeneity of ICU patients, we hypothesized that there may exist different endotypes of congestion. The aim of this study was to identify endotypes of congestion and their association with outcomes. METHODS: We conducted an unsupervised hierarchical clustering analysis on 145 patients admitted to ICU to identify endotypes. We measured several parameters related to clinical context, volume status, filling pressure, and venous congestion. These parameters included NT-proBNP, central venous pressure (CVP), the mitral E/e' ratio, the systolic/diastolic ratio of hepatic veins' flow velocity, the mean diameter of the inferior vena cava (IVC) and its variations, stroke volume changes following passive leg raising, the portal vein pulsatility index, and the venous renal impedance index. RESULTS: Three distinct endotypes were identified: (1) "hemodynamic congestion" endotype (n = 75) with moderate alterations of ventricular function, increased CVP and left filling pressure values, and moderate fluid overload; (2) "volume overload congestion" endotype (n = 50); with normal cardiac function and filling pressure despite high positive fluid balance (fluid overload); (3) "systemic congestion" endotype (n = 20) with severe alterations of left and right ventricular functions, increased CVP and left ventricular filling pressure values. These endotypes vary significantly in ICU admission reasons, acute kidney injury rates, mortality, and length of ICU/hospital stay. CONCLUSIONS: Our analysis revealed three unique congestion endotypes in ICU patients, each with distinct pathophysiological features and outcomes. These endotypes are identifiable through key ultrasonographic characteristics at the bedside. CLINICAL TRIAL GOV: NCT04680728.


Sujet(s)
Pression veineuse centrale , Unités de soins intensifs , Humains , Femelle , Mâle , Adulte d'âge moyen , Sujet âgé , Pression veineuse centrale/physiologie , Veine cave inférieure/imagerie diagnostique , Veine cave inférieure/physiopathologie , Hémodynamique , Soins de réanimation , Analyse de regroupements , Hyperhémie/physiopathologie , Débit systolique , Résultat thérapeutique , Durée du séjour/statistiques et données numériques
8.
Med. intensiva (Madr., Ed. impr.) ; 47(2): 90-98, feb. 2023. tab, graf
Article de Anglais | IBECS | ID: ibc-215030

RÉSUMÉ

Objective To synthesize the evidence about diagnostic accuracy of inferior vena cava collapsibility (IVCc) in prediction of fluid responsiveness among spontaneously breathing patients. Design Systematic review of diagnostic accuracy studies. Setting Intensive care units or emergency departments. Patients and participants spontaneously breathing patients with indication for fluid bolus administration. Interventions A search was conducted in MEDLINE and EMBASE. We included studies assessing IVCc accuracy for fluid responsiveness assessment with a standard method for cardiac output measure as index test. Main variables of interest General information (year, setting, cutoffs, standard method), sensitivity, specificity, and area under the receiving operator characteristics curve (AUROC). Risk of bias was assessed with QUADAS 2 tool. We obtained the pooled sensitivity, specificity and summary ROC curve, with estimated confidence intervals from a bivariate model. We also calculated positive and negative likelihood ratios and developed a Fagon nomogram. Result Eight studies were included with 497 patients. Overall, the studies presented a high risk of bias. IVCc sensitivity was 63% (95% CI – 46–78%) and specificity 83% (95% CI – 76–87%). Despite moderate accuracy of IVCc (SROC 0.83, 95% CI – 0.80–0.86), post-test probability of being fluid responsive based on a 50% pre-test probability led to considerable misclassification. Conclusions IVCc had moderate accuracy for fluid responsiveness assessment in spontaneously breathing patients and should not be used in isolation for this purpose (AU)


Objetivo Sintetizar la evidencia sobre la precisión diagnóstica de la colapsabilidad de la vena cava inferior (cVCI) en la predicción de la respuesta a los líquidos en pacientes que respiran espontáneamente. Diseño Revisión sistemática de estudios de precisión diagnóstica. Ámbito Unidades de cuidados intensivos o servicios de urgencias. Pacientes o participantes Pacientes con respiración espontánea con indicación de administración de bolos de líquidos. Intervenciones Se realizó una búsqueda en MEDLINE y EMBASE. Se incluyeron los estudios que evaluaban la precisión de la cVCI con un método estándar para medir el gasto cardíaco como prueba índice. Variables de interés principales Información general (año, entorno, puntos de corte, método estándar), sensibilidad, especificidad y área bajo curva. El riesgo de sesgo se evaluó con la herramienta QUADAS2. Obtuvimos la sensibilidad combinada, la especificidad y la curva ROC resumida, con intervalos de confianza (IC) estimados a partir de un modelo bivariado. Resultados Se incluyeron 8 estudios con 497 pacientes. La sensibilidad de la cVCI fue del 63% (IC95%: 46-78%) y la especificidad del 83% (IC95%: 76-87%). A pesar de la precisión moderada de cVCI (SROC: 0,83; IC95%: 0,80-0,86), la probabilidad posterior a la prueba de responder a los fluidos basada en una probabilidad anterior al 50% dio lugar a una clasificación errónea considerable. Conclusiones La cVCI tuvo una exactitud moderada para la evaluación de la respuesta a los líquidos en pacientes que respiran espontáneamente y no debe usarse de forma aislada para este propósito (AU)


Sujet(s)
Humains , Veine cave inférieure/physiopathologie , Traitement par apport liquidien , Choc/diagnostic , Intervalles de confiance , Courbe ROC , Valeur prédictive des tests , Sensibilité et spécificité
9.
Sci Rep ; 12(1): 2161, 2022 02 09.
Article de Anglais | MEDLINE | ID: mdl-35140260

RÉSUMÉ

Approximately [Formula: see text] babies are born with only one functioning ventricle and the Fontan is the third and, ideally final staged palliative operation for these patients. This altered circulation is prone to failure with survival rates below [Formula: see text] into adulthood. Chronically elevated inferior vena cava (IVC) pressure is implicated as one cause of the mortality and morbidity in this population. An injection jet shunt (IJS) drawing blood-flow directly from the aortic arch to significantly lower IVC pressure is proposed. A computer-generated 3D model of a 2-4 year old patient with a fenestrated Fontan and a cardiac output of 2.3 L/min was generated. The detailed 3D pulsatile hemodynamics are resolved in a zero-dimensional lumped parameter network tightly-coupled to a 3D computational fluid dynamics model accounting for non-Newtonian blood rheology and resolving turbulence using large eddy simulation. IVC pressure and systemic oxygen saturation were tracked for various IJS-assisted Fontan configurations, altering design parameters such as shunt and fenestration diameters and locations. A baseline "failing" Fontan with a 4 mm fenestration was tuned to have an elevated IVC pressure (+ 17.8 mmHg). Enlargement of the fenestration to 8 mm resulted in a 3 mmHg IVC pressure drop but an unacceptable reduction in systemic oxygen saturation below 80%. Addition of an IJS with a 2 mm nozzle and minor volume load to the ventricle improved the IVC pressure drop to 3.2 mmHg while increasing systemic oxygen saturation above 80%. The salutary effects of the IJS to effectively lower IVC pressure while retaining acceptable levels of oxygen saturation are successfully demonstrated.


Sujet(s)
Procédure de Fontan , Cardiopathies congénitales/chirurgie , Ventricules cardiaques/malformations , Débit cardiaque , Enfant d'âge préscolaire , Simulation numérique , Cardiopathies congénitales/physiopathologie , Ventricules cardiaques/physiopathologie , Hémodynamique , Humains , Modèles cardiovasculaires , Oxygène/sang , Veine cave inférieure/physiopathologie , Pression veineuse , Fonction ventriculaire
10.
Ultrasound Obstet Gynecol ; 59(2): 234-240, 2022 Feb.
Article de Anglais | MEDLINE | ID: mdl-34076923

RÉSUMÉ

OBJECTIVES: To examine the association between inferior vena cava (IVC) diameter and postpartum blood loss and assess whether IVC diameter is a useful marker in the evaluation of intravascular volume status in women with postpartum hemorrhage (PPH). METHODS: This was a prospective case-control study conducted in a university medical teaching center in Afula, Israel, between November 2018 and March 2020. The study cohort consisted of women with a singleton pregnancy who delivered vaginally at term. The PPH group included women diagnosed with PPH based on visually estimated blood loss of 1000 mL or more at the time of enrolment. Hemodynamically unstable women or women with major bleeding at the time of diagnosis were not included. The control group consisted of women with an uneventful fourth stage of labor. IVC diameter was measured using transabdominal ultrasonography during inspiration (IVCi diameter) and expiration (IVCe diameter), and the collapsibility index was calculated ((IVCe - IVCi)/IVCe × 100). The primary outcome was the percentage difference in IVC diameter and collapsibility index between the PPH group and controls. The performance of the IVC collapsibility index in the prediction of the need for blood transfusion in women with PPH was assessed. In order to demonstrate a difference of 20% with a power of 80% and alpha of 0.05, 108 women, at a ratio of 1:2 in the study and control groups, respectively, were needed. RESULTS: Overall, 36 and 72 women were included in the final analysis in the PPH and control groups, respectively. IVCi and IVCe diameters were significantly smaller in the PPH group (0.93 ± 0.30 cm and 1.26 ± 0.32 cm, respectively) than in controls (1.42 ± 0.31 cm and 1.75 ± 0.28 cm, respectively) (P = 0.001 for both). The percentage reductions in IVCi and IVCe diameters in the PPH group compared with controls were 35.0% and 28.0%, respectively. IVC collapsibility index was increased significantly, by 42.9% (26.04 ± 8.67% vs 18.15 ± 5.07%; P = 0.001) in the PPH group compared with controls. IVC collapsibility index was a significant predictor of the need for blood transfusion and correctly predicted 81% of cases. Logistic regression analysis demonstrated that IVC collapsibility index was also a significant predictor of a drop in hemoglobin level of ≥ 2 g/dL (P = 0.001). CONCLUSIONS: IVC diameter changes in response to postpartum blood loss. Measurement of IVC diameter using transabdominal ultrasonography is an objective and useful non-invasive method for the early evaluation of intravascular volume status in women with PPH and for the prediction of cases that might require blood transfusion. © 2021 International Society of Ultrasound in Obstetrics and Gynecology.


Sujet(s)
Hémorragie de la délivrance/imagerie diagnostique , Hémorragie de la délivrance/prévention et contrôle , Période du postpartum , Veine cave inférieure/imagerie diagnostique , Adulte , Études cas-témoins , Femelle , Humains , Israël , Grossesse , Issue de la grossesse , Pronostic , Veine cave inférieure/physiopathologie
11.
Sci Rep ; 11(1): 22413, 2021 11 17.
Article de Anglais | MEDLINE | ID: mdl-34789842

RÉSUMÉ

Cavotricuspid isthmus (CTI) linear ablation has been established as the treatment for typical atrial flutter. Recently, ablation index (AI) has emerged as a novel marker for estimating ablation lesions. We investigated the relationship between CTI depth and ablation parameters on the procedural results of typical atrial flutter ablation. A total of 107 patients who underwent CTI ablation were retrospectively enrolled in this study. All patients underwent computed tomography before catheter ablation. From the receiver-operating curve, the best cut-off value of CTI depth was < 4.1 mm to predict first-pass success. Although the average AI was not different between deep CTI (DC; CTI depth ≥ 4.1) and shallow CTI (SC; CTI depth < 4.1), DC required a longer ablation time and showed a lower first-pass success rate (p < 0.01). In addition, the catheter inversion technique was more frequently required in the DC (p < 0.01). The lowest AI sites of the first-pass CTI line were determined in both the ventricular (2/3 segment of CTI) and inferior vena cava (IVC, 1/3 segment of CTI) sides. The best cut-off values of the weakest AIs at the ventricular and IVC sides for predicting first-pass success were > 420 and > 386, respectively. Among patients with these cut-off values, the first-pass success rate was 89% in the SC and 50% in the DC (p < 0.01). Although ablation parameters were not significantly different, the first-pass success rate was lower in the DC than in the SC. Further investigation might be required for better outcomes in deep CTIs.


Sujet(s)
Flutter auriculaire/physiopathologie , Flutter auriculaire/chirurgie , Procédures de chirurgie cardiovasculaire/méthodes , Ablation par cathéter/méthodes , Valve atrioventriculaire droite/physiopathologie , Veine cave inférieure/physiopathologie , Sujet âgé , Sujet âgé de 80 ans ou plus , Flutter auriculaire/imagerie diagnostique , Femelle , Hôpitaux universitaires , Humains , Mâle , Adulte d'âge moyen , Études rétrospectives , Tomodensitométrie/méthodes , Résultat thérapeutique , Valve atrioventriculaire droite/chirurgie , Veine cave inférieure/chirurgie
12.
Clin Sci (Lond) ; 135(23): 2625-2641, 2021 12 10.
Article de Anglais | MEDLINE | ID: mdl-34783347

RÉSUMÉ

Arterial endothelial dysfunction has been extensively studied in heart failure (HF). However, little is known about the adjustments shown by the venous system in this condition. Considering that inferior vena cava (VC) tone could influence cardiac performance and HF prognosis, the aim of the present study was to assess the VC and thoracic aorta (TA) endothelial function of HF-post-myocardial infarction (MI) rats, comparing both endothelial responses and signaling pathways developed. Vascular reactivity of TA and VC from HF post-MI and sham operated (SO) rats was assessed with a wire myograph, 4 weeks after coronary artery occlusion surgery. Nitric oxide (NO), H2O2 production and oxidative stress were evaluated in situ with fluorescent probes, while protein expression and dimer/monomer ratio was assessed by Western blot. VC from HF rats presented endothelial dysfunction, while TA exhibited higher acetylcholine (ACh)-induced vasodilation when compared with vessels from SO rats. TA exhibited increased ACh-induced NO production due to a higher coupling of endothelial and neuronal NO synthases isoforms (eNOS, nNOS), and enhanced expression of antioxidant enzymes. These adjustments, however, were absent in VC of HF post-MI rats, which exhibited uncoupled nNOS, oxidative stress and higher H2O2 bioavailability. Altogether, the present study suggests a differential regulation of endothelial function between VC and TA of HF post-MI rats, most likely due to nNOS uncoupling and compromised antioxidant defense.


Sujet(s)
Aorte thoracique/physiopathologie , Endothélium vasculaire/physiopathologie , Défaillance cardiaque/physiopathologie , Nitric oxide synthase/métabolisme , Veine cave inférieure/physiopathologie , Animaux , Défaillance cardiaque/étiologie , Défaillance cardiaque/métabolisme , Peroxyde d'hydrogène/métabolisme , Mâle , Infarctus du myocarde/complications , Stress oxydatif , Rat Wistar , Veine cave inférieure/enzymologie
13.
Ann Vasc Surg ; 77: 353.e1-353.e5, 2021 Nov.
Article de Anglais | MEDLINE | ID: mdl-34461237

RÉSUMÉ

Percutaneous mitral valve (MV) repair using MitraClip requires large-caliber venous access. We describe a patient with a ligated inferior vena cava due to an Adams-DeWeese clip placed 50 years prior, who had progressive shortness of breath and lower extremity symptoms secondary to severe mitral regurgitation and chronic iliocaval deep venous thrombosis. Due to comorbidities, MitraClip was recommended over surgery for MV repair. Caval luminal gain was required to facilitate endovascular access for the MitraClip system. Stent-mediated release of the inferior vena cava clip allowed successful passage of the delivery sheath from the common femoral vein to MV and subsequent valve repair.


Sujet(s)
Angioplastie par ballonnet , Cathétérisme cardiaque/instrumentation , Implantation de valve prothétique cardiaque/instrumentation , Prothèse valvulaire cardiaque , Insuffisance mitrale/chirurgie , Valve atrioventriculaire gauche/chirurgie , Instruments chirurgicaux , Procédures de chirurgie vasculaire/instrumentation , Veine cave inférieure/chirurgie , Sujet âgé de 80 ans ou plus , Angioplastie par ballonnet/instrumentation , Humains , Mâle , Valve atrioventriculaire gauche/imagerie diagnostique , Valve atrioventriculaire gauche/physiopathologie , Insuffisance mitrale/imagerie diagnostique , Insuffisance mitrale/physiopathologie , Récupération fonctionnelle , Indice de gravité de la maladie , Endoprothèses , Résultat thérapeutique , Veine cave inférieure/physiopathologie
14.
J Am Heart Assoc ; 10(16): e020854, 2021 08 17.
Article de Anglais | MEDLINE | ID: mdl-34387124

RÉSUMÉ

Background Current right ventricular (RV) volume overload (VO) is established in adult mice. There are no neonatal mouse VO models and how VO affects postnatal RV development is largely unknown. Methods and Results Neonatal VO was induced by the fistula between abdominal aorta and inferior vena cava on postnatal day 7 and confirmed by abdominal ultrasound, echocardiography, and hematoxylin and eosin staining. The RNA-sequencing results showed that the top 5 most enriched gene ontology terms in normal RV development were energy derivation by oxidation of organic compounds, generation of precursor metabolites and energy, cellular respiration, striated muscle tissue development, and muscle organ development. Under the influence of VO, the top 5 most enriched gene ontology terms were angiogenesis, regulation of cytoskeleton organization, regulation of vasculature development, regulation of mitotic cell cycle, and regulation of the actin filament-based process. The top 3 enriched signaling pathways for the normal RV development were PPAR signaling pathway, citrate cycle (Tricarboxylic acid cycle), and fatty acid degradation. VO changed the signaling pathways to focal adhesion, the PI3K-Akt signaling pathway, and pathways in cancer. The RNA sequencing results were confirmed by the examination of the markers of metabolic and cardiac muscle maturation and the markers of cell cycle and angiogenesis. Conclusions A neonatal mouse VO model was successfully established, and the main processes of postnatal RV development were metabolic and cardiac muscle maturation, and VO changed that to angiogenesis and cell cycle regulation.


Sujet(s)
Transcriptome , Dysfonction ventriculaire droite/génétique , Fonction ventriculaire droite/génétique , Animaux , Animaux nouveau-nés , Aorte abdominale/physiopathologie , Aorte abdominale/chirurgie , Anastomose chirurgicale artérioveineuse , Modèles animaux de maladie humaine , Analyse de profil d'expression de gènes , Régulation de l'expression des gènes au cours du développement , Mâle , Souris de lignée C57BL , RNA-Seq , Facteurs temps , Veine cave inférieure/physiopathologie , Veine cave inférieure/chirurgie , Dysfonction ventriculaire droite/étiologie , Dysfonction ventriculaire droite/physiopathologie
15.
BMC Cardiovasc Disord ; 21(1): 193, 2021 04 20.
Article de Anglais | MEDLINE | ID: mdl-33879045

RÉSUMÉ

OBJECTIVES: Antegrade cerebral perfusion (ACP) under moderate hypothermic circulatory arrest is used during total aortic arch replacement surgery (TARS) in patients with acute type A aortic dissection, but it is associated with high mortality and morbidity. We hypothesized that combining ACP with retrograde inferior vena caval perfusion (RIVP) improves outcomes. METHODS: This pilot study was prospective, randomized, controlled and assessor-blinded. Patients scheduled for TARS were randomly treated with either ACP or RIVP + ACP. The primary outcome was a composite of mortality and major complications including paraplegia, postoperative renal failure, severe liver dysfunction, and gastrointestinal complications. Secondary outcomes included neurological complications, length of intubation and requirement of blood products. RESULTS: A total of 76 patients were recruited (n = 38 per group). Primary outcome occurred in 23 patients (61%) in the ACP group and 16 (42%) in the RIVP + ACP group (OR: 0.60, 95% CI: 0.21-1.62; p = 0.31). There was a lower incidence of transient neurological deficits in the RIVP + ACP group (26% vs. 58%, OR: 0.26; 95% CI: 0.10-0.67,p = 0.006;). The RIVP + ACP group underwent shorter intubation (25 vs 47 h, p = 0.022) and required fewer blood products (red cells, 3.8 units vs 6.5 units, p = 0.047; platelet: 2.0 units vs 2.0 units, p = 0.023) compared with the ACP group. CONCLUSIONS: RIVP + ACP may be associated with lower incidence of transient neurological deficits, shorter intubation and less blood transfusion requirement than ACP alone during TARS. Multi-center, randomized trials with larger samples are required to determine whether RIVP + ACP is associated with lower rates of mortality and major complications. TRIAL REGISTRATION: Pilot study of a RCT registered in clinicaltrials.gov (NCT03607786), Registered 30 July, 2018-Retrospectively registered, https://clinicaltrials.gov/ct2/show/NCT03607786 .


Sujet(s)
Aorte thoracique/chirurgie , Anévrysme de l'aorte thoracique/chirurgie , /chirurgie , Implantation de prothèses vasculaires , Perfusion , Veine cave inférieure/physiopathologie , Maladie aigüe , Adulte , /imagerie diagnostique , /mortalité , /physiopathologie , Aorte thoracique/imagerie diagnostique , Aorte thoracique/physiopathologie , Anévrysme de l'aorte thoracique/imagerie diagnostique , Anévrysme de l'aorte thoracique/mortalité , Anévrysme de l'aorte thoracique/physiopathologie , Implantation de prothèses vasculaires/effets indésirables , Implantation de prothèses vasculaires/mortalité , Circulation cérébrovasculaire , Chine , Femelle , Humains , Mâle , Adulte d'âge moyen , Perfusion/effets indésirables , Perfusion/mortalité , Projets pilotes , Complications postopératoires/mortalité , Complications postopératoires/thérapie , Études prospectives , Débit sanguin régional , Facteurs temps , Résultat thérapeutique , Veine cave inférieure/imagerie diagnostique
16.
Am J Emerg Med ; 48: 96-102, 2021 Oct.
Article de Anglais | MEDLINE | ID: mdl-33866270

RÉSUMÉ

BACKGROUND: Assessment of the respiratory changes of the inferior vena cava (IVC) diameter have been investigated as a reliable tool to estimate the volume status in mechanically ventilated and spontaneously breathing patients. Our purpose was to compare the echocardiographic measurements the IVC diameter, stroke volume and cardiac output in different positive pressure ventilation parameters. METHODS: This prospective clinical study with crossover design was conducted in the Intensive Care Unit (ICU). Twenty-five sedated, paralyzed, intubated, and mechanically ventilated patients with volume control mode (CMV) in the ICU due to respiratory failure were included in the study. Positive End-Expiratory Pressure (PEEP) and Tidal Volume (TV) were changed in each patient consecutively (Group A: TV 6 ml/kg, PEEP 5 cmH20, B: TV 6, PEEP 8, C: TV 8, PEEP 5, D: TV 8, PEEP 8) and the changes in vital parameters, central venous pressure (CVP) and ultrasonographic changes in IVC and cardiac parameters were measured. All measures were compared between groups by robust repeated measures ANOVA with trimmed mean. RESULTS: The respiratory changes of the IVC diameter and echocardiographic parameters showed no significant difference in separate mechanical ventilator settings. Significant difference was found in peak and plateau pressure values among groups (p < 0.05). CONCLUSION: The results of our study suggest that IVC related parameters are not affected with different ventilatory settings. Further studies are needed to confirm the reliability of these parameters as a predictor of fluid assessment.


Sujet(s)
Débit cardiaque , Pression veineuse centrale , Ventilation à pression positive/méthodes , Débit systolique , Veine cave inférieure/physiopathologie , Adulte , Sujet âgé , Sujet âgé de 80 ans ou plus , Études croisées , Échocardiographie , Femelle , Humains , Mâle , Adulte d'âge moyen , , Ventilation à pression positive/effets indésirables , Études prospectives , Veine cave inférieure/imagerie diagnostique
17.
Ann Vasc Surg ; 75: 489-496, 2021 Aug.
Article de Anglais | MEDLINE | ID: mdl-33826960

RÉSUMÉ

OBJECTIVE: Inferior vena cava (IVC) injuries have a high mortality rate that may be related to the location of injury and type of repair. Previous studies have been either single center series or database studies lacking granular detail. These have reported conflicting results. We aimed to perform a systematic review and meta-analysis of published literature evaluating ligation versus repair. METHODS: Studies published in English on MEDLINE or EMBASE from 1946 through October 2018 were examined to evaluate mortality among patients treated with ligation versus repair of IVC injuries. Studies were included if they provided mortality associated with ligation versus repair and reported IVC injury by level. Risk of bias was assessed regarding incomplete and selective outcome reporting with Newcastle-Ottawa score of 7 or higher to evaluate study quality. We used a random-effects model with restricted maximum likelihood estimation method in R using the Metafor package to evaluate outcomes. RESULTS: Our systematic review identified 26 studies, of which 14 studies, including 855 patients, met our inclusion criteria for meta-analysis. IVC ligation was associated with higher mortality than IVC repair (OR: 3.12, P < 0.01, I2 = 49%). Ligation of infrarenal IVC injuries was not statistically associated with mortality (OR: 3.13, P = 0.09). Suprarenal injury location compared to infrarenal (OR 3.11, P < 0.01, I2 = 28%) and blunt mechanism compared to penetrating (OR: 1.91, P = 0.02, I2 = 0%) were also associated with higher mortality. CONCLUSIONS: In this meta-analysis, ligation of IVC injuries was associated with increased mortality compared to repair, but not specifically for infrarenal IVC injuries. Suprarenal IVC injury, and blunt mechanism was associated with increased mortality compared to infrarenal IVC injury and penetrating mechanism, respectively. Data are limited regarding acute renal injury and venous thromboembolic events after IVC ligation and may warrant multicenter studies. Standardized reporting of IVC injury data has not been well established and is needed in order to enable comparison of outcomes across institutions. In particular, reporting of injury location, severity, and repair type should be standardized. A contemporary prospective, multicenter study is needed in order to definitively compare surgical technique.


Sujet(s)
Procédures de chirurgie vasculaire , Lésions du système vasculaire/chirurgie , Veine cave inférieure/chirurgie , Adulte , Femelle , Humains , Ligature , Mâle , Appréciation des risques , Facteurs de risque , Résultat thérapeutique , Procédures de chirurgie vasculaire/effets indésirables , Procédures de chirurgie vasculaire/mortalité , Lésions du système vasculaire/imagerie diagnostique , Lésions du système vasculaire/mortalité , Lésions du système vasculaire/physiopathologie , Veine cave inférieure/imagerie diagnostique , Veine cave inférieure/traumatismes , Veine cave inférieure/physiopathologie
18.
Rev. cir. (Impr.) ; 73(2): 166-172, abr. 2021. tab
Article de Espagnol | LILACS | ID: biblio-1388810

RÉSUMÉ

Resumen Introducción: El tromboembolismo pulmonar sin tratamiento, presenta un riesgo de recurrencia del 20%, con una mortalidad del 18% al 26%, en pacientes con embolia pulmonar donde esta contraindica o fracasa la anticoagulación, es necesario interrumpir parcialmente la vena cava inferior, siendo los filtros de vena cava la alternativa más utilizada. Objetivo: Analizar las variables epidemiológicas involucradas en la enfermedad tromboembólica y los resultados de la inserción del filtro de vena cava inferior. Materiales y Método: Estudio retrospectivo, observacional y descriptivo, donde se analiza la inserción sucesiva de 82 filtros de vena cava inferior, en un período de 10 años (2009 al 2019), en el Hospital Dr. Eduardo Pereira de Valparaíso, Chile. Resultados: Sexo femenino 53,6%, edad promedio 60,4 años (rango 19-86), la principal causa para desarrollar enfermedad tromboembólica fueron las enfermedades oncológicas (56,09%), la principal vía de acceso fue la vena femoral común (69,51%), localización del filtro suprarrenal (4,87%), se obtuvo un seguimiento actualizado en el 89,02%, la supervivencia a 5 años fue de 73,17% y a 10 años de 57,32%, morbilidad en relación al procedimiento (9,75%), éxito del procedimiento (97,5%), no hubo mortalidad relacionada. Discusión: Los grandes ensayos, demuestran el beneficio de la interrupción de la vena cava inferior mediante filtros, especialmente en pacientes oncológicos, con elevado riesgo de embolia pulmonar. Conclusión: La inserción de un filtro de vena cava inferior, adecuadamente indicado, es un procedimiento mínimamente invasivo, de bajo riesgo y con excelentes resultados en la profilaxis de la embolia pulmonar.


Introduction: Pulmonary thromboembolism without treatment presents a risk of recurrence of 20%, with a mortality of 18% to 26%. In patients with pulmonary embolism, when anticoagulation therapy is contraindicated or failed, it is necessary to intervene partially the inferior vena cava on which cava vein filters are the main used alternative. Aim: Analyze the epidemiological variables involved on thromboembolic disease, and the outcomes of the inferior vena cava filter insertions. Materials and Method: Retrospective, observational and descriptive study, which analyzes the successive insertion of 82 inferior vena cava filters, over a period of 10 years (2009 to 2019), in the Dr. Eduardo Pereira Hospital, Valparaíso, Chile. Results: Female sex 53.6%, average age 60.4 years (range 19-86), the main cause to develop thromboembolic disease were oncological diseases (56.09%); the main access path was the common femoral vein (69.51%); in a 4.87% the location of the filter was suprarenal. Complete follow-up was obtained in 89.02% of the cases, 5-year survival with 73.17% ratio and 10-years survival of 57.32%, morbidity in relation to the procedure was 9.75%; success of the procedure 97.5%; there was no mortality related. Discussion: Large studies demonstrate the benefits of interruption on the inferior vena cava through filters, especially in cancer patients with high risk of pulmonary embolism. Conclusion: The insertion of an inferior vena cava filter when indication is adequate, is a minimally invasive procedure with low risk and excellent results in the prophylaxis of pulmonary embolism.


Sujet(s)
Humains , Mâle , Femelle , Adulte , Adulte d'âge moyen , Sujet âgé , Sujet âgé de 80 ans ou plus , Veine cave inférieure/physiopathologie , Veine cave inférieure/imagerie diagnostique , Embolie pulmonaire/étiologie , Embolie pulmonaire/prévention et contrôle , Études rétrospectives
19.
Vasc Endovascular Surg ; 55(5): 529-533, 2021 Jul.
Article de Anglais | MEDLINE | ID: mdl-33739196

RÉSUMÉ

Budd-Chiari syndrome (BCS) results from the occlusion or flow reduction in the hepatic veins or inferior vena cava and can be treated with transjugular intrahepatic portosystemic shunt when hepatic vein recanalization fails.1-3 Hypercoagulable patients with primary BCS are predisposed to development of new areas of thrombosis within the TIPS shunt or IVC. This case details a patient with BCS, pre-existing TIPS extending to the right atrium, and chronic retrohepatic IVC thrombosis who underwent sharp recanalization of the IVC with stenting into the TIPS stent bridging the patient until his subsequent hepatic transplantation.


Sujet(s)
Syndrome de Budd-Chiari/thérapie , Procédures endovasculaires , Anastomose portosystémique intrahépatique par voie transjugulaire , Thrombectomie , Veine cave inférieure , Adulte , Syndrome de Budd-Chiari/imagerie diagnostique , Syndrome de Budd-Chiari/physiopathologie , Procédures endovasculaires/instrumentation , Humains , Transplantation hépatique , Mâle , Endoprothèses , Résultat thérapeutique , Veine cave inférieure/imagerie diagnostique , Veine cave inférieure/physiopathologie
SÉLECTION CITATIONS
DÉTAIL DE RECHERCHE