Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 2 de 2
Filter
Add more filters











Database
Language
Publication year range
1.
J Anesth ; 34(4): 561-574, 2020 08.
Article in English | MEDLINE | ID: mdl-32476043

ABSTRACT

For various end-stage lung diseases, lung transplantation remains one of the only viable treatment options. While the demand for lung transplantation has steadily risen over the last few decades, the availability of donor grafts is limited, which have resulted in progressively longer waiting lists. In the early years of lung transplantation, only the 'ideal' donor grafts are considered for transplantation. Due to the donor shortages, there is ongoing discussion about the safe use of 'suboptimal' grafts to expand the donor pool. In this review, we will discuss the considerations around donor selection, donor-recipient matching, graft preparation and graft optimisation.


Subject(s)
Donor Selection , Lung Transplantation , Graft Survival , Humans , Tissue Donors , Treatment Outcome , Waiting Lists
2.
Angiology ; 67(7): 664-9, 2016 08.
Article in English | MEDLINE | ID: mdl-26475710

ABSTRACT

Different patterns of flow and valve gradients can lead to diagnostic uncertainty about the severity of aortic stenosis (AS). Consecutive patients with severe AS (valve area <1 cm(2)) underwent echocardiography and computed tomography. Patients were classified into 4 groups (high-gradient/normal flow [HGNF], high-gradient/low flow [HGLF], low-gradient/normal flow [LGNF], and low-gradient/low flow [LGLF]). Low flow was defined as stroke volume index <35 mL/m(2) and low gradient as a mean aortic gradient <40 mm Hg. Aortic valve calcification (AVC) was calculated using the Agatston score. Of 181 patients, 56, 30, 46, and 49 had HGNF, HGLF, LGNF and LGLF with median AVC of 2048, 2015, 1366, and 1178 AU/m(2) (P < .0001) and valvuloarterial impedance of 4.5, 6.4, 4.2, and 5.9, respectively (P < .0001). Among those with LGLF, AVC was lower in patients with preserved compared to reduced left ventricular ejection fraction (1018 vs 2550 AU/m(2); P < .0001), but valvuloarterial impedance was similar (P = .33). The LGLF AS with preserved ejection fraction is associated with lower AVC and may identify patients with less severe AS in association with an adaptive ventricular response to high afterload.


Subject(s)
Aortic Valve Stenosis/physiopathology , Aortic Valve/pathology , Calcinosis/physiopathology , Hemodynamics , Adaptation, Physiological , Aged , Aged, 80 and over , Aortic Valve/diagnostic imaging , Aortic Valve/physiopathology , Aortic Valve Stenosis/classification , Aortic Valve Stenosis/diagnostic imaging , Blood Flow Velocity , Calcinosis/classification , Calcinosis/diagnostic imaging , Echocardiography, Doppler, Pulsed , Female , Humans , Male , Multidetector Computed Tomography , Predictive Value of Tests , Severity of Illness Index , Stroke Volume , Ventricular Function, Left
SELECTION OF CITATIONS
SEARCH DETAIL