Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 4 de 4
Filter
Add more filters










Database
Language
Publication year range
1.
Z Med Phys ; 33(2): 135-145, 2023 May.
Article in English | MEDLINE | ID: mdl-35688672

ABSTRACT

Monte Carlo (MC) simulations of X-ray image devices require splitting the simulation into two parts (i.e. the generation of x-rays and the actual imaging). The X-ray production remains unchanged for repeated imaging and can thus be stored in phase space (PhS) files and used for subsequent MC simulations. Especially for medical images these dedicated PhS files require a large amount of data storage, which is partly why Generative Adversarial Networks (GANs) were recently introduced. We enhanced the approach by a conditional GAN to model multiple energies using one network. This study compares the use of PhSs, GANs, and conditional GANs as photon source with measurements. An X-ray -based imaging system (i.e. ImagingRing) was modelled in this study. half-value layers (HVLs), focal spot, and Heel effect were measured for subsequent comparison. MC simulations were performed with GATE-RTion v1.0 considering the geometry and materials of the imaging system with vendor specific schematics. A traditional GAN model as well as the favourable conditional GAN was implemented for PhS generation. Results of the MC simulation were in agreement with the measurements regarding HVL, focal spot, and Heel effect. The conditional GAN performed best with a non-saturated loss function with R1 regularisation and gave similarly results as the traditional GAN approach. GANs proved to be superior to the PhS approach in terms of data storage and calculation overhead. Moreover, a conditional GAN enabled an energy interpolation to separate the network training process from the final required X-ray energies.


Subject(s)
Photons , X-Rays , Radiography , Computer Simulation , Monte Carlo Method
2.
Z Med Phys ; 28(3): 196-210, 2018 Aug.
Article in English | MEDLINE | ID: mdl-29107440

ABSTRACT

The ratio of patients who need a treatment adaptation due to anatomical variations at least once during the treatment course is significantly higher in light ion beam therapy (LIBT) than in photon therapy. The ballistic behaviour of ion beams makes them more sensitive to changes. Hence, the delivery of LIBT has always been supported by state of art image guidance. On the contrary CBCT technology was adapted for LIBT quite late. Adaptive concepts are being implemented more frequently in photon therapy and also efficient workflows are needed for LIBT. The MedAustron Ion Beam Therapy Centre was designed to allow the clinical implementation of adaptive image-guided concepts. The aim of this paper is to describe the current status and the potential future use of the technology installed at MedAustron. Specifically addressed is the beam delivery system, the patient alignment system, the treatment planning system as well as the Record & Verify system. Finally, an outlook is given on how high quality X-ray imaging, MR image guidance, fast and automated treatment planning as well as in vivo range verification methods could be integrated.


Subject(s)
Neoplasms/radiotherapy , Radiotherapy/instrumentation , Radiotherapy/methods , Cancer Care Facilities/organization & administration , Cancer Care Facilities/standards , Cancer Care Facilities/trends , Humans , Neoplasms/diagnostic imaging , Radiotherapy/standards , Radiotherapy/trends , Radiotherapy Planning, Computer-Assisted/trends
3.
Radiother Oncol ; 109(3): 409-13, 2013 Dec.
Article in English | MEDLINE | ID: mdl-24128802

ABSTRACT

INTRODUCTION: Image-guided advanced photon and particle beam treatments are promising options for improving lung treatments. Extensive use of imaging increases the overall patient dose. The aim of this study was to determine the imaging dose for different IGRT solutions used in photon and particle beam therapy. MATERIAL AND METHODS: Measurements were performed in an Alderson phantom with TLDs. Clinically applied protocols for orthogonal planar kV imaging, stereoscopic imaging, CT scout views, fluoroscopy, CT, 4D-CT and CBCT were investigated at five ion beam centers and one conventional radiotherapy department. The overall imaging dose was determined for a patient undergoing a lung tumor irradiation with institute specific protocols. RESULTS: OAR doses depended on imaging modality and OAR position. Dose values were in the order of 1 mGy for planar and stereoscopic imaging and 10-50 mGy for volumetric imaging, except for one CBCT device leading to lower doses. The highest dose per exam (up to 150 mGy to the skin) was recorded for a 3-min fluoroscopy. DISCUSSION: Modalities like planar kV or stereoscopic imaging result in very low doses (≈ 1 mGy) to the patient. Imaging a moving target during irradiation, low-dose protocols and protocol optimization can reduce the imaging dose to the patient substantially.


Subject(s)
Lung Neoplasms/diagnostic imaging , Lung Neoplasms/radiotherapy , Radiotherapy Planning, Computer-Assisted/methods , Cone-Beam Computed Tomography/methods , Female , Heavy Ion Radiotherapy/methods , Humans , Lung Neoplasms/pathology , Male , Phantoms, Imaging , Photons , Radiotherapy Dosage , Thermoluminescent Dosimetry/methods
4.
Radiother Oncol ; 108(1): 99-106, 2013 Jul.
Article in English | MEDLINE | ID: mdl-23886591

ABSTRACT

BACKGROUND AND PURPOSE: In the next few years the number of facilities providing ion beam therapy with scanning beams will increase. An auditing process based on an end-to-end test (including CT imaging, planning and dose delivery) could help new ion therapy centres to validate their entire logistic chain of radiation delivery. An end-to-end procedure was designed and tested in both scanned proton and carbon ion beams, which may also serve as a dosimetric credentialing procedure for clinical trials in the future. The developed procedure is focused only on physical dose delivery and the validation of the biological dose is out of scope of the current work. MATERIALS AND METHODS: The audit procedure was based on a homogeneous phantom that mimics the dimension of a head (20 × 20 × 21 cm(3)). The phantom can be loaded either with an ionisation chamber or 20 alanine dosimeters plus 2 radiochromic EBT films. Dose verification aimed at measuring a dose of 10Gy homogeneously delivered to a virtual-target volume of 8 × 8 × 12 cm(3). In order to interpret the readout of the irradiated alanine dosimeters additional Monte Carlo simulations were performed to calculate the energy dependent detector response of the particle fluence in the alanine detector. A pilot run was performed with protons and carbon ions at the Heidelberg Ion Therapy facility (HIT). RESULTS: The mean difference of the absolute physical dose measured with the alanine dosimeters compared with the expected dose from the treatment planning system was -2.4 ± 0.9% (1σ) for protons and -2.2 ± 1.1% (1σ) for carbon ions. The measurements performed with the ionisation chamber indicate this slight underdosage with a dose difference of -1.7% for protons and -1.0% for carbon ions. The profiles measured by radiochromic films showed an acceptable homogeneity of about 3%. CONCLUSIONS: Alanine dosimeters are suitable detectors for dosimetry audits in ion beam therapy and the presented end-to-end test is feasible. If further studies show similar results, this dosimetric audit could be implemented as a credentialing procedure for clinical proton and carbon beam delivery.


Subject(s)
Alanine/chemistry , Heavy Ion Radiotherapy , Medical Audit/methods , Proton Therapy , Radiotherapy Dosage , Humans , Monte Carlo Method , Phantoms, Imaging , Radiotherapy Planning, Computer-Assisted
SELECTION OF CITATIONS
SEARCH DETAIL
...